fh series - flomotion · pdf filefh - hose pumps 30 years experience in hose pumps. the fh...
Post on 04-Feb-2018
221 Views
Preview:
TRANSCRIPT
FH - HOSE PUMPS
30 years experience in hose pumps. The FH hose pump is in many ways the future of pumping. The FH series pump is a fantastically simple pump with a wide range, up to 660 GPM and 217 PSI, that can handle most fluids in most applications.
EXPERIENCED NEWTHINKER
ADVANTAGES• No mechanical seal or stuffing box
• Robust, entirely of ductile iron
• Suitable for aggressive or viscous fluids
• Metering of very corrosive chemicals
• Fully self-priming up to 32 ft
• Damage-free continuous dry running
• Outlet pressures up to 217 PSI
• Very easy maintenance
• Heavy-duty bearings, greased for life
• Two-year warranty
• Plug and Play
• Perfect volumetric flow
• Bidirectional Operation
• Close coupled, compact footprint
• Low sound level: < 70 dB at 3 ft
The FH is a hose pump of the latest design. We have
combined the best available materials with smart de-
sign solutions in order to maximize running time and
minimize maintenance.
Two shoes mounted at 180° on a rotating wheel
compress successively a reinforced rubber hose
that contains a fluid to be pumped. The motion of
the shoes compress the rubber against the pump
housing creates continuous suction at the inlet
of the pump and pushes the fluid to the outlet
of the pump. The sealed pump casing contains
a lubricant that reduces friction of the shoes
moving over the rubber hose. The pumped
fluid is in contact only with the interior of the
rubber hose, thus permitting the pumping
of a wide variety of reactive fluids.
This pump summarizes what we want to achieve:
better pump solutions for our customers.
Our design enhances the pump’s simplicity and
robust principle.
1
EXPERIENCED NEWTHINKER - KEEP IT SIMPLE
We only work with high quality compounded rubbers, reinforced with 2 to 6 individual layers of braided polyamide and with an outer layer made to strict tolerances to ensure perfect compression.
The caracteristics of Flomotion hoses enable them to last approximately 30% longer than other hoses on the market. They also fit the majority of other hose pumps.
For the hose inner layers, 5 materials are available to suit the diversity of the pumped fluids:
• NR (natural rubber) (White marking)• NBR (Buna) (Yellow marking)• NBR Food (Buna) (White & yellow marking)• EPDM (Red marking)• HYPALON (Blue marking)
The FH pump is very easy to use and maintain and therefore addresses what we see as two of the key customer issues:
The need to lower costs and to reduce downtime
This is done by using a pump without valves, pistons, stators or rotating elements in the fluid.
The FH series is designed to make hose changes quick and easy with no technical knowledge required.
PUMP HOSE
WATER TREATMENT lime cream, ferric chloride, activated carbon, sodium hypochlorite, magnesium hydroxide, hydrogen peroxide, coagulant, floculate dispersion, alum, sludge and foams. MINERAL PRO-CESSING sludge with viscosity up to 60 000 Cps, clay up to 800g/l, particle size: 30mm, lead sulfate, pyrite, SABX, cyanide, various acids. CERAMIC barbotine, mould filling, filter press feeding. BUILDING fibrous mortar, plaster, light concrete, cement flooring.
CHEMICAL INDUSTRY various acids, PVDF latex, alcohol, soap, non aromatic solvents. FOOD INDUSTRY tomato sauce, mash potatoes, gelatin, beer yeast, fish paste, olive oil, wine. PAINT water based paint, acrylics, pigments, ink, wall coating. PAPER MILLS latex, kaolin, paper waste sludge, various chemical dosing. AGRICULTURE manure, fertilizer. SUGAR MILLS molasse, liquid sugar and various chemicals.
TYPICAL APPLICATIONS
The in-line pulsation dampener will reduce vibration and water hammers in your piping therefore increasing the hose life.
• Twinhead pump, several pump bodies in- line driven by the same gear motor.• Special excecutions and different connections such as Tri-Clamp, ANSI, NPT...etc• Pump rollers for pump without lubricant• Hose rupture detector and revolution counter
Any other pumping requirements can be considered
OPTIONS FH HOSE CONSTRUCTION
2
TYPE 10 RPM 20 RPM 40 RPM 60 RPM 80 RPM 100 RPM 120 RPM 140 RPM
FH 05 (3 lobes) 0.015 0.03 0.06 0.09
FH10 (3 lobes) 0.04 0.09 0.18 0.26
FH 10 0.07 0.13 0.26 0.40 0.53 0.66 0.79
FH 15 0.22 0.44 0.88 1.32 1.76 2.20 2.64
FH 20 0.29 0.75 1.50 2.20 2.95 3.74 4.27
FH 25 0.88 1.76 3.52 5.28 7.04 8.81 10.57 12.33
FH 32 1.65 3.30 6.60 9.91 13.21 16.51 19.81 23.12
FH 40 2.49 5.15 10.30 15.45 20.61 30.16 30.91 36.06
FHX 40 3.52 7.04 14.1 21.13 28.18 35.22
FH 50 7.71 15.4 30.8 46.23 61.64 77.05
FH 65 10.13 20.3 40.5 60.76 81.01 101.27
TYPE 10 RPM 20 RPM 30 RPM 35 RPM 40 RPM 45 RPM 50 RPM
FHX 80 24.2 48 73 84.76 96.86 108.97 121.08
FH 80 30.8 62 92 107.87 123.28 138.69 154.10
FH 100 52.8 106 159 184.92 211.34 237.75
FH 125 96.9 194 291 339.02 387.45
FLOW TABLE (GPM)
HOW TO USE THE PUMP CURVES
How to use the curves:
1. Select the required flow. This gives you the required pump speed.
2. Move upwards to the calculated discharge pressure.
3. Move to the left for the installed motor power.
4. Determine the fluid’s max. temperature.
5. Move to the left to the calculated discharge pressure.
6. Move downwards to determine your maximum allowed pump speed for the fluids temperature.
FHS SERIESFor customers who require a long shaft technology, we have also developed the FHS series. These pumps are equipped with a removable bearing case for easy bearing maintenance and can be conver-ted into a close coupling FH type pump at any time.
10 20 30 40 50 60 70 80 90 100 110 120
0.34
0.50
0.75
40°C
50°C
60°C
70°C
80°C
P installedmotor (hp)
Pump speed (rpm)
15 30 45 60 75 90 105 120 135 150 165 180Flow (l/h)
ALH PUMPTe
mpe
ratu
re
116
PSI (
8 Ba
r)
44 P
SI (3 B
ar)
0 PSI (0
Bar)
Continuous service Intermittent service*
24/24h
1
23
45
6
104°F
122°F
140°F
158°F
176°F
0.07 0.13 0.20 0.26 0.33 0.40 0.46 0.53 0.59 0.66 0.73 0.79Flow (GPM)
FLOW CURVE - FH PUMP
Continuous use (GPM)
Usage intermittent (GPM)
Occasional use (GPM) (>1 hours/day)
3
FH 05 3 Lobes - TECHNICAL DATASHEET
TYPE A B C D E F G H I J K L M N O P Q
FH 05 4.07 4.53 8.88 3.74 10.67 8.66 9.45 1.32 10.24 11.02 4xø0.35 - 1.71 1.36 ø0.63 * 2.54 3.20
* Hose tail
Dimensions
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
40°C
50°C
60°C
70°C
80°C
116 PSI (8 Bar)
43.5 PSI (3 Bar)
Continous 24/24h
103.40.9
206.81.8
3010.22.7
4013.63.6
5016.94.5
6020.45.4
0.25
0.34
FH 05 (3 lobes)
0.16
Pump speed (Rpm) Flow (l/h)Flow (GPH)
Intermittent* Occasional*
Installed power (hp)
O
CDM N
L
I
J
P
F
G
Q Q
AB E
HH
4 x K
104°F
122°F
140°F
158°F
176°F
Tem
pera
ture
4
40°C
50°C
60°C
70°C
80°C
8 Bars
3 Bars
116 PSI (8
Bar)
43.5 PSI (3 Bar)
Continous 24/24h
10102.6
20205.3
30307.9
4040
10.6
5050
13.2
6060
15.9
7070
18.5
0.50
0.75
FH 10 (3 lobes)
0.34
Pump speed (Rpm) Flow (l/h)Flow (GPH)
Intermittent* Occasional*
Installed power (hp)
FH 10 3 Lobes - TECHNICAL DATASHEET
* Hose tail
Dimensions
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
TYPE A B C D E F G H I J K L M N O P Q
FH 10 4.07 4.53 8.89 3.74 10.67 8.66 9.45 1.32 10.24 11.02 4xø0.35 - 1.71 1.36 ø0.63 * 2.54 3.2
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
O
CDM N
L
I
J
P
F
G
Q Q
AB E
HH
4 x K
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
5
FH 10 (3 lobes)
FH 10 - TECHNICAL DATASHEET
* Hose tail
Dimensions
TYPE A B C D E F G H I J K L M N O P Q
FH 10 4.07 4.53 8.88 3.74 10.67 8.66 9.45 1.32 10.24 11.02 4xø0.35 - 1.71 1.36 ø0.63 * 2.54 3.20
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
40°C
50°C
60°C
70°C
80°C
43.5
PSI (3 Bar)
116
PSI (
8 Ba
r)
10154.0
20307.9
304512
406016
507520
609024
7010528
8012032
9013536
10015040
11016544
12018048
0.50
0.75
FH 10
0.34
Pump speed (Rpm) Flow (l/h)Flow (GPH)
Continous 24/24h Intermittent* Occasional*
Installed power (hp)
O
CDM N
L
I
J
P
F
G
Q Q
AB E
HH
4 x K
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 6
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
FH 10
FH 15 - TECHNICAL DATASHEET
* Hose tail
Dimensions
TYPE A B C D E F G H I J K L M N O P Q
FH 15 2.87 7.6 11.65 5.71 12.68 9.84 11.02 2.03 11.81 12.99 4xø0.51 - 1.93 1.40 ø0.79 * 2.78 4.91
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
40°C
50°C
60°C
70°C
80°C
43.5
PSI (3 B
ar)
116
PSI (
8 Ba
r)
Continous 24/24h
105013
2010026
3015040
4020053
5025066
6030079
7035093
80400106
90450119
100500132
110550145
120600159
0.50
0.75
FH 15
0.34
Pump speed (Rpm) Flow (l/h)Flow (GPH)
Intermittent* Occasional*
Installed power (hp)
O
CDM N
L
I
J
P
F
G
Q Q
AB E
HH
4 x K
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 7
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
FH 15
FH 20 - TECHNICAL DATASHEET
* Hose tail
Dimensions
TYPE A B C D E F G H I J K L M N O P Q
FH 20 2.87 7.6 11.65 5.71 12.68 9.84 11.02 2.03 11.81 12.99 4xø0.51 - 1.93 1.40 ø0.98 * 2.78 4.91
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
40°C
50°C
60°C
70°C
80°C
43.5
PSI (3 B
ar)
116
PSI (
8 Ba
r)Continous 24/24h
108522
2017045
3025567
4034090
50425112
60510135
70595157
80680180
90765202
100850225
110935247
1201020270
0.50
0.75
FH 20
0.34
Pump speed (Rpm) Flow (l/h)Flow (GPH)
Intermittent* Occasional*
Installed power (hp)
O
CDM N
L
I
J
P
F
G
Q Q
AB E
HH
4 x K
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 8
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
FH 20
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 25 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 25
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 40 0
40 to 160 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 40 2
40 to 125 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 40 3
40 to 105 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 40 4
40 to 90 3
Dimensions
TYPE A B C D E F G H I J K L M N O P Q
FH 25 3.74 10.31 31.4 7.48 16.38 12.28 13.86 4.33 22.1 23.6 4xø0.51 - 2.56 2.72 1” 232 PSI 2.72 4.33
C
FI
NM
AB
E
L
HH
Q Q
D
J G
4 x K
P
O
40°C
50°C
60°C
70°C
80°C
145 P
SI (10 B
ar)
109 P
SI (7.5
Bar)
73 PSI (5 Bar)
218 P
SI (1
5 Bar
)
Continous 24/24h
100.20.9
200.41.8
300.62.6
400.83.5
501
4.4
601.25.3
701.46.2
801.67.0
901.87.9
1002
8.8
1102.29.7
1302.611.4
1402.8
12.3
1202.4
10.6
2
3
FH 25
1.5
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 9
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 32 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 32
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 45 0
40 to 140 0
5 (72,5) ≤ ∆P ≤ 7.5 (108.75)0 to 40 2
45 to 140 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 40 3
45 to 110 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 40 4
45 to 80 3
TYPE A B C D E F G H I J K L M N O P Q
FH 32 4.82 13 17.15 9.37 20.69 16.77 18.74 6.21 30.31 31.89 4xø0.51 - 3.27 3.50 1-1/4” 232 PSI 3.58 6.21
Dimensions
C
FI
NM
AB
E
L
HH
Q Q
D
J G
4 x K
P
O
40°C
50°C
60°C
70°C
80°C
3 Bars
8 Ba
rs
145 P
SI (10 B
ar)
109 PSI (7.5 Bar)
73 PSI (5 Bar)
218
PSI (
15 B
ar)
Continous 24/24h
100.381.7
200.753.3
301.13
5
401.506.6
501.888.3
602.259.9
702.6311.6
803.0
13.2
903.3814.9
1003.7516.5
1104.1318.2
1304.8821.5
1405.2523.1
1204.5019.8
2
3
FH 32
1.5
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 10
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 40 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 40
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 40 0
40 to 160 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 40 2
40 to 125 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 40 3
40 to 105 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 40 4
40 to 90 3
TYPE A B C D E F G H I J K L M N O P Q
FH 40 4.82 13 17.15 9.37 20.69 16.77 18.74 6.21 30.31 31.89 4xø0.51 - 3.27 3.50 1-1/4” 232 PSI 3.58 6.21
Dimensions
C
FI
NM
AB
E
L
HH
Q Q
D
J G
4 x K
P
O
40°C
50°C
60°C
70°C
80°C
145
PSI (
10 B
ar)
109 P
SI (7.5
Bar
)73
PSI (5
Bar)
218
PSI (
15 B
ar)
Continous 24/24h
100.592.6
201.175.2
301.757.7
402.3410.3
502.9212.9
603.5115.5
704.1018.1
804.6820.6
905.2723.2
1005.8525.8
1106.4428.4
1307.6133.5
1408.1936.1
1207.0230.9
2
3
FH 40
1.5
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 11
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FHX 40 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FHX 40
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 55 0
40 to 120 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 55 2
40 to 95 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 55 3
40 to 75 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 55 4
40 to 60 3
TYPE A B C D E F G H I J K L M N O P Q
FHX 40 4.33 16.93 15.75 11.46 24.25 13.39 16.54 6.69 33.46 37.4 4xø0.75 - 2.87 3.46 1-1/2” 232 PSI 3.43 6.69
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
145
PSI (
10 B
ar)
109 P
SI (7.5
Bar)
73 PSI (5 Bar)
218
PSI (
15 B
ar)
Continous 24/24h
100.83.5
201.67.0
302.4
10.6
403.2
14.1
504
17.6
604.8
21.1
705.6
24.7
1008
35.2
806.4
28.2
1108.8
38.7
907.2
31.7
1209.6
42.3
3
10
FHX 40
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 12
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 50 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 50
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 30 0
30 to 100 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 30 2
30 to 65 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 30 3
30 to 50 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 30 4
30 to 42 3
TYPE A B C D E F G H I J K L M N O P Q
FH 50 6.48 21.81 20.37 14.17 31.56 20.20 23.35 7.32 37.40 41.34 4xø0.75 - 3.84 4.02 2”232 PSI 6.38 10.10
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
145
PSI (
10 B
ar)
109
PSI (
7.5
Bar)
73 P
SI (5 B
ar)
218
PSI (
15 B
ar)
Continous 24/24h
101.757.7
203.5
15.4
305.2523.1
407
30.8
508.7538.5
6010.546.2
7012.2553.9
8014
61.6
9015.7569.3
7.4
10
FH 50
5.4
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 13
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 65 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 65
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 30 0
30 to 90 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 30 2
30 to 55 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 30 3
30 to 47.5 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 30 4
30 to 40 3
TYPE A B C D E F G H I J K L M N O P Q
FH 65 6.48 21.81 20.37 14.17 31.56 20.20 23.43 7.32 37.40 41.34 4xø0.75 - 3.84 4.02 2-1/2” 232 PSI 6.38 10.10
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
218
PSI (
15 B
ar)
145
PSI (
10 B
ar)
109
PSI (
7.5
Bar)
73 P
SI (5 B
ar)
Continous 24/24h
102.3
10.1
204.6
20.3
306.9
30.4
409.2
40.5
5011.550.6
6013.860.8
7016.170.9
8018.481.0
9020.791.1
7.4
10
FH 65
5.4
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 14
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FHX 80 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FHX 80
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 25 0
25 to 65 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 25 2
25 to 46 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 25 3
25 to 40 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 25 4
25 to 31 3
TYPE A B C D E F G H I J K L M N O P Q
FHX 80 6.22 29.37 23.78 18.62 39.53 22.83 26.77 11.42 45.28 49.21 4xø0.75 - 5.08 5.24 3” 232 PSI 6.57 11.42
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
10 B
ars
7.5 B
ars
5 Bars
15 B
ars
Continous 24/24h
52.7512.1
105.5
24.2
158.2536.3
2011
48.4
2513.7560.5
3016.572.6
3519.2584.8
4022
96.9
4524.75109.0
5027.5
121.1
15
20
FHX 80
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 15
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 80 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 80
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 20 0
20 to 60 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 20 2
20 to 47 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 20 3
20 to 37 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 20 4
20 to 31 3
TYPE A B C D E F G H I J K L M N O P Q
FH 80 10.31 33.31 31.61 21.85 51.97 27.17 32.68 13.58 51.18 55.12 4xø1.06 - 5.53 5.71 3” 232 PSI 8.27 13.58
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
145
PSI (
10 B
ar)
109 P
SI (7.5
Bar)
73 PSI (5 Bar)
218
PSI (
15 B
ar)
Continous 24/24h
53.5
15.4
107
30.8
1510.546.2
2014
61.6
2517.577.1
3021
92.5
3524.5
107.9
4028
123.3
4531.5
138.7
5035
154.1
20
25
FH 80
15
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 16
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 100 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 100
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 15 0
15 to 50 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 15 2
15 to 32.5 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 15 3
15 to 25 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 15 4
15 to 20 3
TYPE A B C D E F G H I J K L M N O P Q
FH 100 11.81 40.94 34.92 26.97 62.01 32.28 37.80 16.14 74.80 78.74 4xø1.06 - 6.69 6.85 4” 232 PSI 14.21 16.14
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
145
PSI (
10 B
ar)
109 P
SI (7
.5 Ba
r)
73 PSI (5
Bar)
218
PSI (
15 B
ar)
Continous 24/24h
56
26.4
1012
52.8
1518
79.3
2024
105.7
2530
132.1
3036
158.5
3542
184.9
4048
211.3
4554
237.8
20
15
30
FH 100
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 17
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
* Intermittent use: Minimum of 1 hour stop after 2 hours use * Occasional use: Maximum 1 hour per day
Beware: Remove one shim If Temperature exceeds 60° Celsius (140° Fahrenheit)
FH 125 - TECHNICAL DATASHEET
SHOE SHIMMING TABLE - FH 125
Pressure bar (psi) Speed - Rpm Number of shims - thickness 0.5 mm
∆P ≤ 5 (72.5)0 to 10 0
10 to 35 0
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)0 to 10 2
10 to 27.5 1
7.5 (108.75) ≤ ∆P ≤ 10 (145)0 to 10 3
10 to 25 2
10 (145) ≤ ∆P ≤ 15 (217.5)0 to 10 4
10 to 20 3
TYPE A B C D E F G H I J K L M N O P Q
FH 125 10.37 50.12 40.87 30.91 68.90 39.37 44.88 19.68 74.80 78.74 4xø1.06 - 11.81 9.13 5” 232 PSI 25.98 19.68
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
L
M N
I
J
P
D C
E
AB
F
G
Q Q
HH
4xK
O
Dimensions
40°C
50°C
60°C
70°C
80°C
145 P
SI (10
Bar
)10
9 PSI (7
.5 Bar)
73 PSI (5 Bar)
218
PSI (
15 B
ar)
Continous 24/24h
511
48.4
1022
96.9
1533
145.3
2044
193.7
2555
242.2
3066
290.6
3577
339.0
4088
387.5
40
30
50
FH 125
Pump speed (Rpm) Flow (m3/h)Flow (GPM)
Intermittent* Occasional*
Installed power (hp)
FLOMOTION SYSTEMS, Inc. - 165 Creekside Drive, Suite 112, Buffalo, NY 14228-2103 - USA
Toll Free: (800)909-3569 ~ (716)691-3941 - Fax : 716-691-1253 - info@FlomotionSystems.com - www.FlomotionSystems.com 18
Tem
pera
ture
104°F
122°F
140°F
158°F
176°F
ALL DIMENSIONS ARE IN INCHES. ALL DIMENSIONS AND TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
FLOMOTION SYSTEMS Inc.165 Creekside Drive, Suite 112Buffalo, NY 14228-2103Tel:800-909-3569 (U.S. & Canada) or 716-691-3941 Fax:716-691-1253E-Mail: info@flomotionsystems.com
For more information about our worldwide locations, approvals, certifications, and local representatives, please visit FlomotionSystems.com.
FLOMOTION SYSTEMS reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this
bulletin, are provided for your information only and should not be relied upon unless confirmed in writing. Certified drawings are available upon request. © 2013 FLOMOTION SYSTEMS, INC.