icpdas - power meter

Post on 09-Jan-2017

50 Views

Category:

Technology

4 Downloads

Preview:

Click to see full reader

TRANSCRIPT

ICP DAS Training on Power Monitoring

and Management Solution

Power Meter Concentrator �  Collect 24 power meters (include max. of 4x PM-4324) �  4GB micro SD card for data logging up to six months

PMD-2201(7”)AvailableinDec.

PMC-5151

Built-inWeb-basedAnalysis&Report

Power Meter Available Model Phase Type Loop CTs

included Secondary Signal

Wire Lead

Yes PM-3112-100 Single Phase 2 Yes mA 1.8m

Yes PM-3114-100 4 Yes mA 1.8m

Nov. PM-3033 Three Phase 1 N/A 5A N/A

Nov. PM-3133P N/A 333mV N/A

Yes PM-3133-100 Yes mA 1.8m

Yes PM-3133-360P Yes 333mV 4m

Nov. PM-4324P Single or Three Phase

24 or 8

N/A 333mV N/A

Yes PM-4324-100P Yes 333mV 4m

Current Transformer (333mV)

Model Remark Signal Inside Diameter

Wire Lead

Current Ratio

4SCA030 -100P 60A/333mV 10 mm 4 m 12 4SCA031 -160P 100A/333mV 16 mm 4 m 20 4SCA032 -240P 200A/333mV 24 mm 4 m 40 4SCA023 -360P 300A/333mV 36 mm 4 m 60

■ Note 1: Used for PM-3133P and PM-4324P ■ Note 2: Needs to set proper Current ratio ■ Note 3: Accuracy may be 5% or greater without calibration with power Meter

Model Name not Confirmed yet

CT Inside Diameter

Current Transformer Selection ■ Solid Core CTs: Place over conductor prior to inserting in the breaker. Secondary output is 1A or 5A.

Solid Core CT:800A/5A

■Clip on (Hinged) CTs: Open the clip, place around conductor and snap closed.

I

Easy to install

Difference between PM-3133-100 and PM-3033

PM-3033canconnectto5AsecondaryoutputofSolidCoreCT

Important Notice Unless a load (i.e. meters, relays, etc.) is connected to the CT, current transformers should always be shorted across the secondary terminals. The reason is very high voltages will be induced at the terminals.

Secondary Side

Safety Design ■ CTs comes with PM-3133-100 (mA signal)

built-in diode to avoid high voltage introduced. ■ CTs comes with PM-3133-360P (333mV signal)

built-in diode and resister to avoid high voltage introduced. conform EC60950-1 SELV(Safety Extra-low Voltage Circuit)

Flexible CTs (1000A/333mV) ■ Accuracy Under Verifying ■ Model Name not Confirmed yet

Benefit of PM-4324 1.  Monitoringmax.8x3phaseor24xsinglephase,

orcombinaPonofsingleorthreephase.2.  Easywiringfor

■ RS-485■ ReferencePowerInput■ PowerSupply

3.DirectlyuseACpowersupply

Anextra24VDCpowersupplyisnotneeded

R

S

T

3P3W Mode

220V

220V

Benefit of ICP DAS solution �  HW, compared to panel mounting

�  DIN-rail mounting saves installation cost and time

�  SW, compared to SCADA �  Save license fee �  Save time to develop �  Built-in function of parameter setting, smart chart and report

engine, data storage and can backup to a FTP server �  Support complete PC webpage and simplified cell phone

webpage

�  Permissions control function to support a system administrator and five general users simultaneously log in

PMC-5151:Browse and monitor power data by cell phone

New Application Story for Semiconductor Industry

�  Target: �  FAB: Collect power information of TOP1 equipments (ie, CVD,

Chemical Vapor Deposition) �  Parking Lot �  Dormitory

�  Equipment Bought for FAB �  17x PMC-5151 �  3x PM-4323-160P, over 50x PM-3033 & PM-3133

�  Why choose ICP DAS �  Web based HMI for easy operation. (SCADA is not needed) �  Built-in data logger and analysis report �  PMC Data Server to export data to MS SQL

Reference � Web Site http://pmms.icpdas.com/en/index.html

�  Live Demo: �  http://rd3demo.icpdas.com/ �  Password: Admin, User

� Solid Core CTs �  http://www.omega.com/pptst/MFO_RCT.html

top related