instruments chns overview_2011
Post on 14-Jun-2015
1.025 Views
Preview:
TRANSCRIPT
A member of elementargroup 2September 2010
Elementar Analysensysteme
Elementar headquarter
Hanau, close to Frankfurt/MainGermany in the heart of Europe
Frankfurt am Main
Hanau
A member of elementargroup 3September 2010
• Development, production and central sales, service and marketing support in the head office Hanau, Germany.
• Own offices in • United States• P.R.China• France• Brasil• United Kingdom.
• Represented by exclusive and selected agents in
more than 50 countries.
Elementar worldwide
A member of elementargroup 4September 2010
The Organisation
• Production and quality control in strict conformity to the current norms and regulations. The company has acquired the ISO 9001:2008 certification.
• Own R&D department with skilled specialists for instruments development and software.
• Trained service engineers in all countries.Service and application trainings for instrument users.
• Fully equipped application laboratory in Hanau to perform scientific research and to support instrument users for their analytical tasks.
A member of elementargroup 5September 2010
Application fields
• CHNOS elemental analysis
• Agricultural analysis
• Water analysis
• Solid fuel analyzers
• Special elemental analyzers
A member of elementargroup 6September 2010
The ProductsMicro CHNS/O Elemental Analyzer
vario MICRO cube
• Completely new instrument for CHNS analysis, market introduction in 2006.
• Unique method for combustion gas separation by Temperature Programmed Desorption. TPD (patent pending), combines high performance of purge-and-trap with simplicity of GC.
• Complementary to the existing line of instruments.
A member of elementargroup 7September 2010
Temperature programmed desorption with single-column technology
The „TPD“ technology is a very straight forward method to separate the gaseous compounds by complete adsorption and subsequent element specific desorption. It guarantees baseline separation of CHNS under all conditions.
C,H,SC,H,S NN
A member of elementargroup 8September 2010
The Products Universal CHNS/O Elemental Analyzer
vario EL cube
• Concept and performance of the 4th generation of the most successful CHNOS elemental analyzers sets again the standards for this class of instruments.
• Less than 1 mg pharmaceuticals
can be analyzed just as precise as
larger amounts of soil samples.
• Micro to semi-macro sample size
• CHNS+O+Cl
• Unrivalled versatility
A member of elementargroup 9September 2010
The ProductsThe art of elemental analysis
vario MACRO cube
• CNFast and safe alternative to Kjeldahl for N-Protein analysis
• CHNApplications for fossil fuels, incinerationplants and environmental analysis.
• CNSSoil, plant, environmental or industrial samples.
• CHNSThe first CHNS macro analyzer!
Applications for all kinds of samples
with inhomogeneities or low element concentrations.
A member of elementargroup 10September 2010
Purge and Trap with multi-columnchromatography
In the vario EL cube and vario MACRO cube a multi-column technology is realized to separate even larger sample sizes. The gaseous compounds are adsorbed at element specific columns and one after the other released by a temperature supported desorption. All elements are analyzed simultaneously from a single sample.
HHSS CC NN
A member of elementargroup 11September 2010
The ProductsMacro elemental analyzers with reusable sample crucibles
vario MAX• N/CN
may be operated in carbon/nitrogen modeor the faster N/protein mode acc. to the Dumas combustion method.
• CNS analyzer applications include plants, soil or industrial products.
• CHN addresses the needs of carbon, hydrogen and nitrogen analysis in fossil fuels and incineration plants.
A member of elementargroup 12September 2010
The ProductsThe compact power in N-protein analysis
rapid N cube
• Nitrogen/protein analyzer according to Dumas for routine analysis of samples such as food or animal feed up to 1 g sample weight.
• The rapid N cube is a fast, safe and environmentally friendly alternative to the classical Kjeldahl method.
• The rapid N cube is a particularly reliable and durable instrument.
A member of elementargroup 13September 2010
rapid N cube
The rapid N cube – the most economic way to determine N/protein by the DUMAS method – the most efficient alternative to Kjeldahl.
Protein is calculated by multiplying the total nitrogen amount with a factor f. This factor varies between 5.35 – 6.35.
A member of elementargroup 14September 2010
The ProductsTOC + TNb analyzers
vario TOC cube
• Most modern high temperature TOC/TNb analyzer (2008) based on the "cube" platform.
• Largest concentration range from 5 ppb to 60,000 ppm TOC in liquids or 0-50 mg C (or 100%) in solids.
• Unique concept for integrated liquidsampling of up to 80 samples orsolids up to 120 sample positions.
• Innovative matrix separation forthe analysis of very difficult samplessuch as brine, sludges or suspensions.
A member of elementargroup 15September 2010
The ProductsSpecial elemental analyzers
rapid CS cubeSulfur/Carbon analyzer
• Total sulfur/carbon analyzer for fast and precise analysis in coal and other organic and most inorganic substances.
• Based on the "cube" technology withstate of the art micro electronics and mechanics introduced in 2008.
• Unmatched performance from ppm to 100% with just one high performance NDIR detector.
• Lowest cost per analysis and very long operation time based on high temperature catalytic combustion in a quartz glass tube.
A member of elementargroup 16September 2010
trace SN cubeHigh-end for petrochemical applications
• Double furnace system for uncompromised performance in SN mode
• Detection range from ppb to %
• Suitable for gaseous, liquid and solid samples
A member of elementargroup 17September 2010
The ProductsIsotope ratio analysis
• In 2008 Elementar acquired the product line Gas-IRMS from Thermo/GVI.
• Isoprime Ltd., a 100% daughter company of Elementar, manufactures the comprehensive line of products for the analysis of stable isotope ratios of C, N, S, H and O in all kind of samples in geochemistry, agriculture, food authenticity, environmental control, etc.
A member of elementargroup 18September 2010
How to select within the vario family: Micro or Macro Analyzer
Main distinguishing feature is the amount of organically bound carbon
to be analyzed in one sample.
• Absolute carbon detection range:
0 – 7 mg vario MICRO cube
0 – 40 mg vario EL cube
0 – 100 (150) mg vario MACRO cube
0 – 200 (400) mg vario MAX
A member of elementargroup 19September 2010
How to select within the vario family II
Sample handling and injection (2)
Samples (liquids or solids) are filled in an open and reusable crucible
(steel or ceramic) and moved by a robot arm into the combustion
zone.
After combustion the crucible with
the remaining ash (minerals)
is automatically removed.
Analyzer: vario MAX
A member of elementargroup 20September 2010
How to select within the vario family III
• Sample handling and injection (3)
Samples (liquids or gases) are injected directly into the
combustion
zone by means of an automatic or manual syringe.
Analyzers: vario EL cube with VLS
trace SN
A member of elementargroup 21September 2010
The cube family of elemental analyzers – how to decide ?
.....the easiest way: TAKE THEM ALL!
A member of elementargroup 22September 2010
Elementar thanks for your attention!