© AssetGen Limited1
Integrating Environment Monitoring & Data Center Management
1. What are AssetGen & Sensorium iBMS?2. Why link them together?3. What is the difference between monitoring and management?4. How does Sensorium present data center status and loading5. How AssetGen support data center management and capacity6. Examples of planning and change impact analysis7. How the “integration” works in practice8. Summary of results
David Cuthbertson CEO, AssetGenJohn Hardy CTO, Advanced Desktop Solutions
Visio is a registered trademark of Microsoft Corporation- All rights acknowledged
© AssetGen Limited2
Why Link the Two Systems
• Sensorium iBMS monitoring is focused on environment and fixed infrastructure providing monitoring, alerting and usage statistics– Reporting and alerting is vital to give feedback on actual usage– Often the view is limited to facilities / data centre teams – The environment doesn’t change as rapidly as the IT systems
• AssetGen focuses on the management and controls covering fixed and IT infrastructure, presenting different information sets for project and operations teams.– Past, current and planned states of servers, racks, power, networks– Device inventory, connectivity and change management– Visualisation (Visio) of floors, racks, networks, power, services
© AssetGen Limited3
Different Toolset Focus – ExamplesSensorium iBMS AssetGen
Fault/ThresholdAlerting
Realtime PowerMonitoring
RecoveryPlanning
AuditTrails
Work OrderPlanning
InventoryManagement
Billing &Charging
Capacity Planning & Reporting
Device Connectivity(Power, LAN, SAN)
BusinessImpact View
Network TopologyView (Visio)
Rack LayoutView (Visio)
LoadingHistory Current
Status
Actual loadingBy Power Strip
ChangeManagement
Power TopologyView (Visio)
Temperature &Humidity Monitoring
Environment Monitoring & Alerting Data Centre Management & Control
CCTV, Security, FireIntegration
An alert has come in –what and who is affected?
A PDU is overloadedWhat are my options?
Does the server take as much power as expected?
What is the actual usagevs planned usage?
We’re running on UPS -what is non-critical?
© AssetGen Limited4
Sensorium iBMS In More Detail
Rack power status
Power totals by PDU, phase
Data Centre total usage
Rack threshold status
Web BrowserView
© AssetGen Limited5
Example Power, Alerts, Usage History etc.
Actual power, volts, amps
Link to CCTV and alerts
Usage reports by day, week, etc.
© AssetGen Limited6
Sensorium iBMS SummarySensorium iBMS
Sensorium Benefits- Real time monitoring - Customised for each facility- Easy to use- Alerting against thresholds- History of actual usage- Links to different types of power,
temperature, humidity inputs- Can give usage by power port
AssetGen provides the IT device information to help interpret results, identity risks and plan power usage (plus a few other things)
PDU
Power Strips
Power Strips
Power Strips
UPSIncoming Feeds
CCTV
Access Facilities
IT Platforms
AssetGen
© AssetGen Limited7
AssetGen in More Detail
3. Visio floor & rack plans
2. Find racks with space, power, etc.
1. Capacity reports space, port usage
5. Planned install of server
6. Usage and status of ports
4. Coloured by role, owner etc.
© AssetGen Limited8
AssetGen in More Detail (2)
Floor PlanFloor Plan
Rack PositionRack Position
Service impactService impact
Power SupplyPower Supply
Network ConnectionsNetwork Connections
BLADE_BIRM01
UK
_BIR
M01_BLA
DE
-01
UK
_BIR
M01_BLA
DE
-02
UK
_BIR
M01_BLA
DE
-03
UK
_BIR
M01_BLA
DE
-04
BLAD
E-B
IRM
01.BLAD
E-S
W1
BLAD
E-B
IRM
01.BLAD
E-S
W2
UK
_BIR
M01_BLA
DE
-05
UK
_BIR
M01_BLA
DE
-09
UK
_BIR
M01_BLA
DE
-10
UK
_BIR
M01_BLA
DE
-12
BLADE_BIRM01
UK
_BIR
M01_BLA
DE
-01
UK
_BIR
M01_BLA
DE
-02
UK
_BIR
M01_BLA
DE
-03
UK
_BIR
M01_BLA
DE
-04
BLAD
E-B
IRM
01.BLAD
E-S
W1
BLAD
E-B
IRM
01.BLAD
E-S
W2
UK
_BIR
M01_BLA
DE
-05
UK
_BIR
M01_BLA
DE
-09
UK
_BIR
M01_BLA
DE
-10
UK
_BIR
M01_BLA
DE
-12
H/W BuildH/W Build
Visualisation (Visio)
1. Local path
PatchPanel
2. End to End path
PatchPanel
PatchPanel
3. All devicesconnected to theSwitch, SAN, PDU
SVRWIN001
SW-BHAM-CORE1
SW-BHAM-CORE2
PatchPanel
PatchPanel
Connectivity & Path Management
Capacity & Work Flow- Rack space- Power utilisation- Network ports (SAN, patch also)- Hardware fill- Planned work & build orders
Risk & Impact Control- Impact of hardware changes- Identify single points of failure- Service impact of hardware / software changes- Components supporting critical systems- Recovery and continuity plans
© AssetGen Limited9
AssetGen Example 1 – Adding a ServerInstalling a server and connecting it to infrastructure resources in AssetGen takes
2-3 minutes in total – compare this to existing methods with Excel, Visio etc.
Fixed Infrastructure(Cabling, Power, Cabinets, Rooms, Buildings)
Hardware Infrastructure ComponentsPCs, Network, Servers, UPS, Storage, Other
Virtual Infrastructure ComponentsPCs, Network, Servers, Storage, DBMS
ApplicationsPC or server based
ServicesEnd user, infrastructure, supplier
Business ProcessesDepartmental, Company
Sensorium AssetGen
Adding a server to AssetGen- Updates the rack diagram- Updates the rack capacity- Updates the inventory- Links the server to power, networks, KVM, SAN- Updates infrastructure capacity reports
space, network, SANpower utilisation reports
- Updates planned activities (work orders)- Updates an audit trail
Will also update Visio diagrams- Rack diagram- Network, power, SAN topology- Floor plans- Service maps
© AssetGen Limited10
AssetGen Example 2 – Change Impact Analysis
Mapping technical and service dependencies to critical components with AssetGen means it takes a few seconds for projects or operations staff to;
1. Identify the impact of a fault or overload indication from monitoring systems such as Sensorium iBMS, NMS or server dashboards
2. The potential impact of a server reboot or fault on software, users and services
3. The devices and services affected by a reboot of an infrastructure device such as a network switch, San controller, blade chassis
4. The hardware and services impacted by a planned (or unplanned) outage on a power PDU or circuit breaker
5. The hardware delivering the top 10 critical services (for DR, charging, etc.) and single points of failure at power, network and functional levels
© AssetGen Limited11
Linking AssetGen and Sensorium iBMS
Both systems have many strengths, so where does integration give us additional benefits or capabilities?
Reduce fault finding time by automatically linking from Sensorium cabinets or power strips to access AssetGen device, connectivity and services dataIdentify current usage during planning activities by automatically linking from AssetGen cabinets, power strips to get real time power, temp etc. from SensoriumAutomatically link from Visio diagrams of floorplans, rack layouts and power diagrams to access real time data from SensoriumImport data from Sensorium into AssetGen to combine actual with planned power capacity data, avoiding over-engineeringProduce power usage reports from AssetGen for billing and charging by technology, users/customers, services based on actual usage from SensoriumCorrelate changes in actual power usage with changes in IT equipment installs / removals / transformation projects
© AssetGen Limited12
Enhancing Sensorium iBMS with AssetGen data
Click on rack for AssetGeninventory and
changes
© AssetGen Limited13
Enhancing AssetGen with Sensorium iBMS data
99999
99999
UK_BIRMCC_PDU1
UK_BIRMCC_PDU2
PWR01-03-A
PWR01-04-A
PWR01-05-A
PWR01-06-A
PWR01-07-A
PWR01-03-B
PWR01-04-B
PWR01-05-B
PWR01-06-B
PWR01-07-B
UK_BIRM_UX01 UK_BIRM_UX02 UK_BIRM_UX09 UK_BIRM_UX10 UK_BIRM_UX03 UK_BIRM_UX04
UK_BIRM_UX05
UK_BIRM_UX06
UK_BIRM_UX07
UK_BIRM_UX08
Power Topology Diagram
Front
1 2 3 4 5 6 7 8 17 18 19 20 21 22 23 249 10 11 12 13 14 15 161 2 3 4 5 6 7 8 17 18 19 20 21 22 23 249 10 11 12 13 14 15 16
PP01-03-01
UID
HPProLiant
DL380 G5
COMPAC T
1 2
1 2 3 4 5 6 7 8
POWERSUPPLY SUPPLY
POWER
SPAREONLINE
MIRROR
CAGERISER
PCI
PROC PROC
LOCKINTER
TEMPOVER
FANS
PP
MP
PM
DIMMS
UID
HPProLiant
DL380 G5
COMPAC T
1 2
1 2 3 4 5 6 7 8
POWERSUPPLY SUPPLY
POWER
SPAREONLINE
MIRROR
CAGERISER
PCI
PROC PROC
LOCKINTER
TEMPOVER
FANS
PP
MP
PM
DIMMS
SVR-BHAM-010301
440
I
CRITICAL
MAJOR
MINOR
USER
COMPACT
microsystems
440
I
CRITICAL
MAJOR
MINOR
USER
COMPACT
microsystems
UK_BIRM_UX01
PROLIANTPROLIANT
SERVERWIN0001
tsr 4554
PROLIANTPROLIANT
SERVERWIN0099
PROLIANTPROLIANT
SERVERWIN00078
PROLIANTPROLIANT
SERVERWIN00199
Rear
Actual loading by power strip and port
Check actual rack loading against
capacity allocated
Confirm loading required in failover mode
© AssetGen Limited14
Making it Happen
It took less than a day to prove the integration worked between AssetGen and Sensorium iBMS, enabling hyperlinking between systems and exchange of data.
Existing AssetGen and Sensorium installations can leverage more value from the current systems data.
Power and IT infrastructure changes can be assessed and optimised much more easily, with risks easily determined by combining actual data with planning tasks.
Warnings and alerts from the BMS system can be more quickly interpreted for incident and impact management.
© AssetGen Limited15
Case Study Summary
Monitoring systems are designed to present current status, loading and past utilisation, so integration with AssetGen enables interpretation of complex infrastructure alerts and change impacts.
The integration techniques described here also work with monitoring, discovery and work flow systems spanning multiple technologieseg. Power, Network, Servers, Storage, Systems, Services