ip ran configuration

Post on 31-Dec-2015

424 Views

Category:

Documents

18 Downloads

Preview:

Click to see full reader

DESCRIPTION

ip

TRANSCRIPT

Contents

Infrastructure aspects

Protocol Stack

Iub over IP migration

Defining network topology and nodes interconnectivity Install and configure ET-MFX boards in the nodes Migration of Iub to IP Clean obsolete objects

Infrastructure Aspects Infrastructure aspects

Protocol Stack Protocol Stack

Iub over IP migrationIub over IP migration

Defining network topology and nodes interconnectivityDefining network topology and nodes interconnectivity Install and configure ET-MFX boards in the nodesInstall and configure ET-MFX boards in the nodes Migration of Iub to IPMigration of Iub to IP Clean obsolete objectsClean obsolete objects

Infrastructure Aspects

Iub

Iub: ET-MFX12 or ETMFX13

– 7 port built in Ethernet switch

– 1 SFP + 6 Electrical Eth. ports

Variant with 6 SFP and 1

Electrical ports available (ETMFX13)

– Synch server

RBS 3810 with IP (P6)

RNC 3810

Infrastructure Aspects Iub: ETMFX11

For Iub and O&M IP/Ethernet interface with optional Ethernet switch 1 SFP + 6 Electrical Eth. ports Synch client

RBS with CBU In P6.0, only RBS nodes equipped with CBU boards

can be configured for IP transport.

RBS without CBU In P6.1 support for IP transport is also possible with

older RBS nodes (RBS2/3), with upgraded HW (GPB and TUB).

The RBS has to be equipped with a GPB with at least 512 MB RAM. The recommended version is ROJ 119 2106/51, revision R2 or later.

The RBS has to be equipped with a Timing Unit Board 2 (TUB 2) variant.

RBS 3206

RBS 3000 with IP

Protocol Stack Infrastructure aspectsInfrastructure aspects

Protocol Stack

Iub over IPIub over IP migrationmigration

Defining network topology and nodes interconnectivityDefining network topology and nodes interconnectivity Install and configure ET-MFX boards in the nodesInstall and configure ET-MFX boards in the nodes Migration of Iub to IPMigration of Iub to IP Clean obsolete objectsClean obsolete objects

Protocol Stack

Control Plane User Plane

DCH, HS-DSCH, E-DCH FACH, PCH, RACH FPs

NBAP

TransportNetworkLayer

RadioNetworkLayer

Radio Network Control Plane

ALCAP (Q.2630 , Q.2150.2)

Physical Layer (E1, J1, STM-1 etc)

Transport Network Control Plane

Radio Network User Plane

Node Synch

AAL2SAAL-UNI

ATM

AAL0SAAL-UNI

Ethernet

and Node Sync (over FACH)

IP

UDPSCTP

Network Synch

NTP

Iub Protocols from ATM to IP

Iub over IP migration Infrastructure aspectsInfrastructure aspects

Protocol Stack Protocol Stack

Iub over IP migration

Defining network topology and nodes interconnectivity Install and configure ET-MFX boards in the nodes Migration of Iub to IP Clean obsolete objects

IP address plan for RNC IubType of IP address Max

numberRedundancy

Number of IP addresses

IP host for Iub UP (ET-MFX) 16 - 16

IP host for Iub CP (module MP) 33 2 66

Subtotal (RNC IP hosts): 82

Default Gateway (external) 1 3 3

Actual subnet address 1 - 1

Broadcast address 1 - 1

Total (RNC with subnet): 87

Closest Subnet size 128 (41 spare)

IP address plan for RBS Iub

Type of IP address Max number

Redundancy

Number of IP addresses

IP host for UP (ET-MFX) 1 - 1

IP host for CP 1 - 1

Subtotal (RBS IP hosts): 2

Default Gateway (external) 1 1-3 1 (typical)

Actual subnet address 1 - 1

Broadcast address 1 - 1

Total (RBS with subnet): 5

Closest Subnet size 8 (3 spare)

IP Addressing/VLAN - OverviewBasic principles:

Logical separation of O&M and traffical IP Transport VLAN ID 100-110 traffic, VLAN ID 900-910 O&M (typical) Share physical resources

One-to-one mapping Subnetwork <-> VLAN Traffical and O&M IP networks can use private IP addresses

(see RFC 1918) The recommendation is to use addresses from the 10-network

(10.x.y.z) IP Addressing considerations:

Addressing for Iu/Iur in RNC (common with CN Nodes) Iub IP Transport

L3 based (one subnet per node) L2 based (large subnets)

O&M IP Addressing

Install and configure ET-MFX12 boards in the RNC

Insert ET-MFX12 Board(s) and Cabling

Ethernet/IP Backhaul (port 6 for electric and port 7 for optical cable)

Redundancy Jumper from other ET-MFX (Port 1)

Install and configure ET-MFX12 boards in the RNC

The ET-MFX board is the key product to be installed in the RNC in order to handle Iub traffic over IP

For Installing the ET-MFX boards in the RNC confirm that the following prerequisites are fulfilled

ET-MFX12 boards are available

RNC is Hardware R4 or higher

The RNC has available slots for installing the new ET-MFX12 boards, Extension sub-rack preferred

The RNC is running P6 software

Install and configure ET-MFX12 boards in the RNC

The appropriate cable kits and applicable ICF connections plates are available

A Thin Client configured to run EMAS

Java 1.4.2_8 or higher is installed on the Thin Client

Mo and/or BCT configuration scripts are available and prepared according to network IP address plan

OSS R5.3 up and running in case of BCT files are used

Procedure to install ET-MFX Board on RNCOpen RNC Element ManagerAssure that the slot is available

Figure above show slot 4th is available

Verify that Auto Configuration is activatedAutoConfigurationAllowed -> True

Install and configure ET-MFX12 boards in the RNC

Before Installing the ET-MFX12 boards. The ET-MFX12 Software Allocation role must be assigned to the right slots,

Run Expand RNC Tool Part 1

Run the RNC Hardware Configuration Tool – Part 1

Go to Tool -> RNC Hardware Configuration Tool. Then assign software allocation to the ET-MFX slot. Then press Apply.

Select for slot(s) appropriate Software Allocation Role

Install and configure ET-MFX12 boards in the RNC

Go back to the MS (Main subrack) frame and insert the RNC UserId and Password in the blank field, then press Apply

Install and configure ET-MFX12 boards in the RNC

Run Expand RNC Tool Part 2 Insert the RNC UserId and Password in the blank field, then press Apply

Install and configure ET-MFX12 boards in the RNC

ET-MFX12 board are installed

Install and configure ET-MFX12 boards in the RNC

If Objects are installed. Create a new Configuration Version

Install and configure ET-MFX12 boards in the RNC

Check that every System Created Object is installed

IpAccessHostEtIpAccessHostGPB

IpSystem

IpInterface

InternalEthernetPort EthernetSwitch

ExchangeTerminalIp

IpAccessHostPool

EthernetSwitchPort

SwitchStp

SwitchPortStp

ManagedElement Equipment Subrack

PlugInUnit

Slot

TransportNetwork

Sctp

Red frame = System created

Procedure to install ET-MFX Board on RBSSlot position based on RBS type:

The Hardware Configuration and Software allocation procedure is the same on RBS

RBS Type ET Slots

RBS 3206F/E 2, 3, 22 and 23

RBS 3206M 2, 3 and 4

RBS 3518 2

RBS 3418 2

Install and configure ET-MFX11 boards in the RBS

Verify that Auto Configuration is activated

Install and configure ET-MFX11 boards in the RBS

Install ET-MF11 Board in the RBS

Ethernet/IP Backhaul (port 6 for electric and port 7 for optical cable)

O&M from CBU (port 3)

O&M from ET-MFX port 2

Install and configure ET-MFX11 boards in the RBS

Connect the Ethernet transport cable in the System port cable, the O&M cable must be connected from the CBU board to the ET-MFX11 board.

Add “jumper” cable for O&M from ET-MFX (System port 2) to CBU.

Install and configure ET-MFX11 boards in the RBS

IpAccessHostEt

IpSyncRef

IpSystem

IpInterface

InternalEthernetPort EthernetSwitch

ExchangeTerminalIp

IpAccessHostGPB

EthernetSwitchPort

SwitchStp

SwitchPortStp

ManagedElement Equipment Subrack

PlugInUnit

Slot

TransportNetwork

Sctp

Red frame = System createdYellow frame = Initial configurationBlue frame = Site Basic (On-site)Green frame = Site Specific (ARW, BCT)

Check that System created Object is installed

Procedure to configure ET-MFX board on RNC (Prerequisites)ATND document from Ericsson Network

Design teamIP address allocationET-MFX installed on RNC and RBSRouter configuration prepared

Procedure to configure ET-MFX board on RNC (Sample Script)Confirm IpInterface MO already created on

RNC

Define and Configure Control Plane

Define and Configure User Plane

RNC_MS-27_ControlPlane_Sample.mo

RNC_MS-27_UserPlane_Sample.mo

Define and Configure IubLink

Manually change this value according to ATND

Equipment=1,Subrack=MS,Slot=27,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1a. enableVlanb. pbitQueueMapc. untaggedIngressVidd. vlanMembership

Equipment=1,Subrack=MS,Slot=27,PlugInUnit=1,ExchangeTerminalIp=1,InternalEthernetPort=1a. dscpPbitMap

Equipment=1,Subrack=MS,Slot=27,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1,EthernetSwitchPort=6a. operatingModeb. pbitQueueMapc. systemPortd. untaggedIngressVide. vlanMembership

RNC_MS-27_Iublink_Sample.mo

Procedure to configure ET-MFX board on RBS (Sample Script)Confirm IpInterface MO already created on

RNC

Define and Configure User Plane

Define and Configure Control PlaneRBS_ControlPlane_Template.mo

RBS_UserPlane_Template.mo

Add NTP Synchronization

Manually change this value according to ATNDEquipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1

a. enableVlan

b. pbitQueueMap

c. untaggedIngressVid

d. vlanMembership

Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminalIp=1,InternalEthernetPort=1

a. dscpPbitMap

Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1,EthernetSwitchPort=6

a. operatingMode

b. pbitQueueMap

c. systemPort

d. untaggedIngressVid

e. vlanMembership

RBS_IPSync_Template.mo

Keep this locked for RBS. Because RSTP (Rapid Spanning Tree Protocol) is not used in RBS

Rapid Spanning Tree Protocol (RSTP) is used for protection switching in the Ethernet network, so that a failure in a single board does not stop the traffic from any other board and so that for any one failing link there is always a combination of other links that can transfer the traffic (board protection)

Add the following ref to this parameter userPlaneIpResourceRef

Backup CV

RNC Precheck before ATM-IP migrationCheck on the following object are unlocked

and enableda. (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=MS,Slot=27,PlugInUnit=1b. (UNLOCKED) 1 (ENABLED)

Equipment=1,Subrack=MS,Slot=27,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1,EthernetSwitchPort=6

c. (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostPool=Iubd. (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostEt=MS-27

IP ping test from object IpAccessHostEt until all the configured IP in PE router & RBS can be reached

RBS Precheck before ATM-IP migrationCheck on the following object are unlocked

and enableda. (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=2,PlugInUnit=1b. (UNLOCKED) 1 (ENABLED)

Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminalIp=1,EthernetSwitch=1,EthernetSwitchPort=6

c. (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostEt=Slot-2

IP ping test from object IpAccessHostEt until all the configured IP in PE router & RNC can be reached

Check on IPsync are unlocked and enabled

ATM to IP migrationMake a test call, verify that the site is working fineLock Utrancell and IubLink in RNCChange the user/controlplanetransportoption in RNC> lset IubLink=Iub_BENTMU controlPlaneTransportOption atm=0,ipv4=1

> lset IubLink=Iub_BENTMU userPlaneTransportOption atm=0,ipv4=1

Change the user/controlplanetransportoption in RBS> lset Iub=BENTMU controlPlaneTransportOption atm=0,ipv4=1

> lset Iub=BENTMU userPlaneTransportOption atm=0,ipv4=1

Unlock Utrancell and IubLink in RNCMake a test callCreate CV both on RNC and Node B

Thank you

top related