MANUAL LIGHT DIMMER
GND
HotIn
HotOut
HotIn
HotOut
Warnings!High Voltage present inside the controller. If you need to reach inside the controllerdisconnect power first.
This product shoud be used to adjust the light intensity on incandescent light bulbs
only. Cumberland is not liable for any problems that may arise from use with other
lighting systems.
Tools Required
Screwdriver Cordless DrillWire Strippers
Installation
1. Hang the Manual Light Dimmer using the fourscrews provided.
2. Make sure all power supplies are disconnectedbefore breaking any wires.
3. Open the Manual Light Dimmer, and find allconnections. See fig. 1
4. Connect all wires using the wiring diagram infig. 1 below.
5. Re-connect power.6. Installation complete.
J2
J3
J9
J8
J7J4
J6
J5 J10
J11
J12
C2
TR1
R1
R3
R6
R4
R2
R5R8
R7
5k
C1
TR3
MBS4991
TR4
MBS4991
TR2
GND
HotIn
HotOut
HotIn
HotOut
Branch 1Branch 1 Branch 2Branch
Center
ON
Control
CUMBERLAND. Assumption, IL 62510 Phone 217-226-4421 Fax 217-226-4420• • •
Manual Part No. 4801-5040 rev 1-15
Bra
nch
1B
ranch
1B
ranch
2B
ranch
2
Hot (120vac)
Hot (120vac)
Neutral
Neutral
Lights
Earth Ground
Fig. 1
Operation
1. To place full power on incandescent light blubs,place switch to position. See fig. 2
2. To turn incandescent light blubs off,place switch to positon. See fig. 2
3. To adjust light intensity, place switch toposition, adjust the lights using the
knob in the center. See fig. 2
On
Off
Variable
Fig. 2
4501-5071
Manual LightDimmer
Variable Variable
On(prendido) (prendido)
Electrical shock may occur if the enclosure is openedwith power connected to the unit. Wiring and connections must complywith all national and local electrical codes. Installation by qualifiedelectrician required!
On
Circuit 1 Circuit 2
Off Off Off Off3
2
1
4
5 6
7
8
9
10
Warning!
(circuito 1)
(variable) (variable)
(circuito 2)
Knob(Variable Adjust)
Lights
ON
OFF
20
ON
OFF
20
20 Amp
20 Amp
BreakerBox
Ratings and Specifications
Room Temp: 122 F / 50°C MaximumInput : 120 VAC 50/60 HzOutput: 4800 Watts, 40 Amps Maximum
Per Circuit: 2400 Watts, 20 Amps Maximum*Circuits Should Be Fused @ 20 Amps Max.
°
Circuits Should Be Protected With ABreaker Rated At 20 Amps Maximum.
IMPORTANT