mitsubishi electric 2011 air conditioning product catalogue
Post on 26-Mar-2016
363 Views
Preview:
DESCRIPTION
TRANSCRIPT
Corporate SalesTel: 0870 3000 070
Fax: 0870 3000 080
ScotlandTel: 01506 444960
Fax: 01506 444961
ManchesterTel: 0161 866 6060
Fax: 0161 866 6081
BirminghamTel: 0121 741 2800
Fax: 0121 741 2801
BristolTel: 01454 202050
Fax: 01454 202900
IrelandTel: +353 (0)1 419 8800
Fax: +353 (0)1 419 8890
email: sales@meir.mee.com
LeedsTel: 0870 3300 347
Fax: 0870 3300 348
London Central RegionTel: 0207 928 6810
Fax: 0207 928 6569
London North RegionTel: 01707 282480
Fax: 01707 282481
Sales Offices:
London South RegionTel: 01689 881030
Fax: 01689 881031
20
11
Air C
ond
itionin
g P
rod
uct C
ata
log
ue
After Sales Service: 0161 866 6089
email: air.conditioning@meuk.mee.com
web: www.mitsubishielectric.co.uk/aircon
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England
General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric
are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the
equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly
developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general
particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of
which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in November 2010 SAP No. 237005
Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers,
wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
Wor ld ofMaking a
Dif ference
The Renewable Solutions Provider
2011 Air ConditioningProduct Catalogue
Features Key
Mitsubishi Electric Partner Programme
Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors
a totally new and unique set of benefits. There are two categories within the programme - Accredited
Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s
stage of growth. All customers signing up to the programme standards are committing to continued
training and professional development.
For more information please contact your local sales office
Mitsubishi Electric Training Options
Mitsubishi Electric has four state-of-the-art training suites based at different
locations around the country for your convenience. Providing training for
all levels of expertise, our courses are taught by experienced engineers,
with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089
Many of our systems have an energy label of A. These systems meet the criteria of the
Energy Technology List and hence could qualify for 100% first year enhanced capital allowances
(whole system cost and ‘reasonable’ cost of installation). For further information please
go to www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.
UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
Note: The fuse rating is only a typical value, it is the responsibility of a
qualified electrician/electrical engineer to select the correct cable size
and fuse rating based on current regulation and site specific conditions.
the name Mitsubishi is
synonymous with excellence
Known the world over, Mitsubishi is a trusted global leader
associated with a variety of products and services. Founded
in 1921, Mitsubishi Electric quickly rose to the forefront of the
air conditioning industry - a position we still enjoy today.
Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the internal environment of any building, large or
small. It does not only provide cooling when required, but also heating and often hot water can
be supplied from the same system. Providing heating and hot water as part of an integrated
air conditioning system is far more efficient than traditional heating methods such as gas and as a result
reduced running costs and emissions can be realised. More and more people are experiencing the
benefits of comfortable working, living and leisure environments made possible with air conditioning.
As market leaders, we pride ourselves in providing high performance, competitive systems with
low running costs and emissions.
Environmental AwarenessMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy
and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of
our factories and UK operations are ISO14001 registered, the international standard that ensures
that we are fully aware of the environmental impact of all our processes and ensures we have
procedures in place to reduce them. However, we have gone far further than any accepted
minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future
that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further
as it looks to install behavioural change in our own operations and our wider sphere of influence
with contractors, consultants and end users. It looks to highlight the advantages and opportunities
provided, by ensuring all of our activities are undertaken with consideration to the environment.
We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise
awareness of energy use in Europe.
The Forest Stewardship Council (FSC) is an international network promoting responsible
management of the world's forest. The paper this catalogue is printed on supports the
development of responsible forest management worldwide. The wood comes from FSC
certified, well managed forests, company controlled sources and/or recycled material.
www.green-gateway.co.uk
www.sustenergy.org
www.mitsubishielectric.com/eco
Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects
Low unit height - minimal intrusioninto occupied space
Double thermostat function - control the temp via a sensorin the controller or the unit (wired remote controllers only)
I-Save - Recalls the preferred (preset) temperaturevia a single button
Catechin filter - improves air quality and preventsthe spread of bacteria and viruses within the room
Air Cleaning filter - catches dust particles andcontaminates, helping to keep the air fresh
Anti-Allergy Enzyme filter - artificial enzymecatalyst on the filament catches allergens
Swing Vane Mode
Auto Vane Shutter - when unit is switched offthe vane automatically closes
Wide Swing - distributes air laterally by up to 150º
Long Airflow Mode - particularly suitable foruse in long, narrow spaces
Infra-red remote controller
Optimised rotary or scroll compressor
Econo Cool - allows set temperature to be raised by 2ºCwithout any loss of comfort and a 20% gain in energy efficiency
Inverter control - adjusts performance to economically matchthe demand for heating or cooling
Auto-Restart
Quiet operation
72 different airflow patterns - 2, 3 or 4 way discharge
High ceiling compatibility through wide flow air outlets
Auto-Changeover
Hot Start - draught prevention
Factory charged refrigerant up to 30m
Standard filter
Optional high efficiency filter
Plasma Duo filter system
Quick clean design
Drain lift pump as standard
Optional drain lift pump
High external static pressure
Optional high static fan motor
Fresh air knockout
Branch duct knockout
Ceiling soiling prevention
Replace Technology available
Refrigerant volume check function
I-See Sensor
Duty Standby Operation
Contents
Page 1
The Mitsubishi Electric Air ConditioningProduct Catalogue The new 2011 catalogue offers you moreinformation than ever before. That’s because theMitsubishi Electric air conditioning range containsmany new models, plus a fully comprehensiveselection of control options to choose from.
In addition to increasing the range, we’ve also triedto help you find what you need more quickly andefficiently. We hope you will find it an interestingand informative read.
If there is anything not covered in the catalogueand you want to know more, simply contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you can visit our websiteat www.mitsubishielectric.co.uk/aircon for further information.
Page 13 - 62
Page 63 - 131
Page 133 - 243
Page 245 - 264
Page 265 - 307
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
M Ser ies &Mr Sl im Split-System Air Conditioning
Inverter technology saves energy for two main reasons:
1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary to match the exact requirement of the room.
2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.
The entire R410A M Series and Mr Slim ranges are inverter controlled
The adoption of this technology as standard by Mitsubishi Electric shows our commitment to both increasing your savings, as well as protecting the global environment.
Page 5
Mitsubishi ElectricSplit-Systems
M Series and Mr Slim
Mitsubishi Electric’s M Series and Mr Slim range of split-systems havebenefited from massive investment year on year, the overall result being a vastly improved and more flexible collection of split-systems.
One of the most important features of the inverter controlled range is the adoption of A Control,allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening theremote controller functionality. As a result of this it is possible to connect Mr Slim indoor units toMXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim StandardInverter models have further increased the range, offering a lower cost option, whilst stillincorporating Mitsubishi Electric’s energy saving inverter technology. These models are nowalso available as a 3-phase option.
A Control is Mitsubishi Electric’s control mechanism for providing standard remote controllerfunctions alongside system diagnostics, fault code monitoring and the ability to interface withthe MELANS (Mitsubishi Electric Air Conditioning Network Solution) equipment such as theAG150 Centralised Controller, TG2000, Modbus, Trend, LonWorks® & BACnet® etc.
Page 4
Energy Saving:Reduced Power Consumption &
Increased Efficiency
Vector-Wave Eco InverterThis technology uses a specially designed microprocessor to produce the most efficient waveform in response to varyingcompressor motor rpm. By improving operating efficiencyfrom low to high speeds, annual electricity costs are reduced.
Power Receiver and Twin LEV ControlMitsubishi Electric has developed a power receiver and twinLEVs (linear expansion valves) that optimise the performanceof the compressor. By ensuring optimum control in responseto the operating waveform and outdoor temperature, thistechnology is tailored to the characteristics of the R410Arefrigerant to enhance operating efficiency.
Application of new technologies in MitsubishiElectric inverter systems significantly enhancethe generic benefits of inverter driven systems.
Reluctance DC Rotary CompressorsThe centralised winding DC motor uses lesscopper wiring than a conventional version and features a high density, centralised winding method that raises motor winding efficiency to 96%. Units incorporating this motor also benefit from a low starting currentas well as a stable set point.
Joint Lap DC MotorThis unique “Poki Poki” motor is manufactured using a jointlapping technique. This reliable motor operates based on ahigh density, high magnetic force, making it extremely efficient.
Highly Efficient Scroll CompressorsThe scroll compressor is equipped with a ‘Frame ComplianceMechanism’ that allows movement in the axial direction of theframe supporting the moving scroll.
This construction realises up to a 27% improvement incompressor efficiency by reducing both leakage and friction losses.
DC Fan MotorA high-efficiency DC motor drives the fan of the outdoorunits. It offers up to 60% greater efficiency than an equivalent AC motor.
Simple Partial Switching Method,PAM ControlCompared to the conventional active filter method, the simplepartial method PAM (Pulse Amplitude Modulation) controlfound on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inverter, PAM control also allows for greater power and efficiency.
PAM adjusts the form of the current wave so that it is close tothat of the supply voltage wave. High harmonics are reducedand 98% of the electricity is utilised.
Heatexchanger
Compressor
Powerreceiver
Heatexchanger
LEV 1 LEV 2
Page 7
Energy SavingTechnology Reduced Power Consumption & Increased Eff iciency
Page 6
Normal Inver ter vs. PAM
Total Energy Conservation
Page 9
*1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8B140VA and MXZ-8B160YA Multi-Splitoutdoor units
Page 8
Re-use ofExisting PipeworkUpgrading Existing
R22 & R407c Systems* 1
In general the upgrading of existing R22systems to modern efficient R410A systemshas been a difficult or expensive option. This is because the existing pipework wouldeither have to be replaced, or cleaned with dedicated specialist equipment.
These actions were necessary as the chlorineresidue from R22 system pipework causedchemical reactions with the lubricating oilsused in HFC compressors, the result beingpoor performance and system failure.
Mitsubishi Electric’s
Replace TechnologyThe M Series*2 & Mr Slim ranges incorporate ‘ReplaceTechnology’ to allow the upgrade of systems using existingpipe work, without the need to apply any special cleaningmachines.
M Series, S Series, Power Inverter (35/50) and StandardInverter (100/125/140) utilise Ether oil or the MitsubishiElectric patented Hard Alkyl Benzene (HAB) oil, a unique oilthat is more tolerant of contamination. By combining theseoils with developments in oil separator technology it is possiblefor these models to use existing pipework without any special operations.
All other Mr Slim models use a friction reduction “Heat Caulking” method, whereby friction inside the scrollcompressor is reduced by coating the edge of the blade, thereby suppressing the increase in temperature that causes refrigerant oil deterioration.
The Advantages of Replace Technology
For Installers
Installation time is reduced significantly
It is not necessary to purchasenew piping for R410A refrigerant
Time-consuming pipe cleaning isnot necessary when employingReplace Technology
For Tenants and Owners
Reduces installation time causingless disruption of business
Saves on installation costs
Reduced Installation
Time & Cost
44kW Cooling Capacity
100
(10.0kW)
125
(12.5kW)
140
(14.0kW)
200
(19.0kW)
250
(22.0kW)
400
(38.0kW)
500
(44.0kW)
Mr Slim Power Inverter
Mr Slim Power Inverter
Mr Slim Standard Inverter
Page 11
Mr Slim Power Inverter
Model / Size
MSZ-HC-VA(B)
MSZ-GE-VA
MSZ-FD-VA
PKA-RP-HAL/KAL
MFZ-KA-VA
SEZ-KD-VAQ
PEAD-RP-JAQ
PEA-RP-GAQ
SLZ-KA-VAQ
PLA-RP-BA(2)(3)
PCA-RP-KAQ
PCA-RP-HAQ
PSA-RP-GA
Split-System Product Range Overview
M Series Inverter
(Multi-Split)
M Series Inverter
22
(2.2kW)Multi-Split only
25
(2.5kW)
35
(3.5kW)
50
(5.0kW)
60
(6.0kW)
71
(7.1kW)
0.9kW Cooling Capacity
Indoor Units
Page 10
M Series Inverter
M Series Inverter
M Series Inverter
Multi-Split
M Series Inverter
Multi-Split
M Series Inverter
Multi-Split
Outdoor Units
PUHZ-RP60/71VHA4PUHZ-P125-250V/YHA(3) PUHZ-RP35/50VHA4 PUHZ-RP100-250V/YKAPUHZ-P100V/YHA(3)MUZ-GE25-35VA
MUZ-FD25-35VABH
SUZ-KA25/35VA2
MXZ-2C52VA
MUZ-GE50VA
SUZ-KA50-60VA2
MUZ-GE60-71VA
SUZ-KA71VA2
MXZ-4C80VA
MXZ-5C100VA
MXZ-6C120VAMXZ-3C54VA
MXZ-4C71VA
MUZ-HC25-35VA(B)
Mr Slim Standard Inverter
Mr Slim Zubadan Inverter
PUHZ-HRP71-125V/YHA2
M Series Power Multi
MXZ-8B140VA
MXZ-8B160YA
Simple technologyat its best
Page 12
Designed tofit anywhereAvailable in a variety of options, our Split-System range fits in wherever it’sneeded. Indoor units can be four way blow cassettes, ducted, wall, floor or ceiling mounted.
Up to eight indoor units can then beconnected to a single outdoor unitproviding the ideal air conditioning solution.
The Adaptable Split-System Range
Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’ cost of installation).
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
For further information please go to www.eca.gov.uk
M Ser ies Room Air Conditioning
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
Perfect for Small to Medium Sized Applications
*1 MSZ-GE22-35VA
Page 14
The M Series Range
Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioningsolution. Quick to install and also one of the quietest units on the market (as low as19dBA*1), this newly designed, attractive rangeoffers the perfect way to ensure a comfortableenvironment with the minimum of disruption.
Surprisingly affordable, the efficiency of the M Series rangepresents substantial savings in heating mode, when comparedwith more conventional heating systems. Additional featuressuch as ‘Econo-Cool’ allow airflow to be precisely directedtowards users, allowing set temperatures to be raised by 2ºC with no loss in comfort and a 20% gain inenergy efficiency.
Flexible enough to suit a range of applications, the M Seriesrange includes models that will run up to eight indoor unitsper outdoor unit. With vastly increased pipe length and heightdifferences over its R407c predecessors, the M Series range isextremely versatile, helping to make system application easier. This diagram shows how a typical multi-split system could be installed into a medium sized office for example.
Highly Energy EfficientThe entire M Series range is now available using invertertechnology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved when compared to direct on line models.
Increasingly aware of the importance of protecting theenvironment, the M Series range is made as small as possibleto reduce raw material use and the emissions generated indistribution. The whole range also has a very high recoveryrate when recycled, so that materials can be used again at theend of the systems life. Many models also make use of a newair filtering system containing the compound Catechin, whichhelps to improve air quality and prevent the spread of bacteria and viruses.
M Series offers the end user some of the highest energyefficiency ratings available, alongside greater applicationflexibility. Lower running costs and reduced CO2 emissionsthroughout the life of the system, along with increasedcomfort for consumers are virtually guaranteed and Mitsubishi Electric has made M Series the natural choice for today’s small to medium sized application market.
Designedto Fit
Anywhere
Page 15
Quick Clean Design can reduce your electricity bill by approximately 30%
*1 Electricity bill comparison of operation under a fixed temperature with 8g of soil on the fan and also without.
Electricity
bill increases
by 5%*1
Electricity
bill increases
by 25%*1
Heat Exchanger Fan Air Vent
Silent OperationTechnological improvements reducing operating sound levels
Only19dBA
in‘silent mode’
*1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.
Clean, ComfortableEnvironment
Catechin FilterCatechin is a bioflavonoid that is found in green tea.Bioflavonoids are a group of chemical substances present inmany plants, that have both antiviral and antioxidant qualities.In addition to these benefits, Catechin also offers excellentdeodorising characteristics; which is why Mitsubishi Electric usesthis compound in its air conditioning filters to not only improveair quality, but to also prevent the spread of bacteria andviruses within a room. The filter can be easily removed andwhen washed regularly, deodorising effectiveness should last for more than 10 years. MSZ-GE22-50VA / MSZ-HC wallmounted and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.
Unlike conventional models with a grilled air intake, wallmounted models feature a smoothly contoured, flat panelfinish with a top air intake that not only improves aesthetics,but also helps to reduce noise as the heat exchanger area isfully covered. In fact, noise level during normal operation isonly 19dBA for the MSZ-GE22-35VA in ‘silent mode’, makingit one of the quietest indoor units on the market. This is as aresult of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother,quieter flow of air.
Alongside this, the wide diameter of the fan produces greaterairflow at lower fan speeds and the uneven pitch betweeneach fan blade helps to eliminate unwanted noise.
“Anti-Allergy Enzyme Filter” mechanism
� Artificial enzyme catalysts on the filamentcatch the allergens.
� The artificial enzyme catalyst helps the chemicalreaction with Oxygen and severs the S-S bonds.*1
� Proteins with severed S-S bonds are no longer allergen proteins.
The vane on the MSZ-GE and MSZ-FD wall mounted models easily detaches, allowing access to the louvres. These can then beopened outwards (without any special tools) for quick cleaning of the heat exchanger, fan and air vents. Regular cleaning will increaseboth operating efficiency and energy-savings.
Quick Clean Design
Operating StatusMonitoringMonitor lamps located on the right of the indoor unit provideat-a-glance recognition of the air conditioner operating status.When the difference between the set temperature and roomtemperature is more than 2°C, both monitor lamps will turnon. If it is less than 2°C, only the upper lamp will light.
Page 16 Page 17
The "I-See Sensor" automatically moves from side to side, monitoring floor temperature over a wide area of 150°.
Conventional air conditioners control indoor temperature by using only thetemperature of the intake air at the top of the room. As a result, the floor leveltemperature, which exerts such a crucial impact on the temperature thatpeople feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.
Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.
Plasma DeodorisationThe “Platinum catalyst deodorising filter” captures small foul-smelling substances in the air, then breaksdown the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter.
Plasma Electrode UnitA plasma electrode unit is mounted inside the airconditioner. Electro-discharge is used to generateozone & plasma. The collaboration betweenozone & plasma and two special filters creates a dynamic plasma air cleaning function.
Plasma Air PurificationThe “Anti-allergen electric enzyme filter” usesthe power of the static electricity charged inthe filter, as well as plasma generated in theplasma electrode unit to capture the bacteria,pollen and other allergens in the air, which arethen neutralised by the enzyme in the filter.
Mould Fighter mechanism
Step 1After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).
Step 2The heat exchangeris dried for about40 mins by the fanmode operation.
The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth ofspores of mould. The ozone generated in the plasma electrode unit attacks the mould spores,reducing mould growth by about 20%.
Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.
Field Test Result: Size 35. Sweden, 23rd January 2008
The FD Series line-up is engineered forhigh energy efficiency and low soundlevels. The I-See Sensor, Plasma-Duofilter system and other superb functionsraise the comfort evel to even greater heights.
The MSZ-FD Series
High Energy EfficiencyWith the latest inverter technology, energy efficiency is improvedby about 20%. Specifically, more than 5.0 is attained for boththe COP and EER for a size 25.
Powerful Heating CapacityThe VABH outdoor unit is engineered for use in cold regions (down to -25ºC ambient) and is equipped with a powerful compressor,enabling an improvement in heating capacity. The heating power is raised by about 30% over the standard model and keeps theroom comfortable even on cold days.
Quiet RunningA larger line flow fan is included in the FD model. This allowsstable capacity with fewer rotations, reducing operating noise.
MSZ-FD
Size 25
Size 35
Side view of
MSZ-FD
Cooling
Heating
Cooling
Heating
20dBA
20dBA
21dBA
21dBA
Ø106
Page 18 Page 19
Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying functions. These functions are engineered to changeair dirt particles from micron to nano-size in scale.
Outdoor Unit
Branch Box
Branch Box
Example of aPower Multi system
using eight indoor units
� 14kW and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology
� Ability to connect up to eight indoor units acrossthe M Series and Mr Slim product range within amaximum capacity index of 20.2kW
� Total Pipe Length of 115m / Height Difference of 30m
� Single and 3 phase power supplies available
� Connection of indoor units is through either a 3-way(PAC-AK31BC) or 5-way (PAC-AK52BC) branch box,either singularly or with two in combination
� Individual control of each indoor unit is now possible(ON/OFF and Setpoint)
� Low starting and running currents
� Connection to M-NET system via MAC-399IFinterface (one per indoor unit needed)
The MXZ-8B Power Multi Inver ter Heat Pump Multi-Split Outdoor Units
MXZ Multi-Split Systems
Ideal for apartments or small commercial buildings
All Mitsubishi
Electric MXZ
multi-split outdoor
models have an
energy label
of ‘A’
Page 20 Page 21
Excellent FeaturesAvailable in wall and floor mounted, the M Series range is quiet, economicto run and easy to install. The outdoorunits can run up to eight indoor units, allcontrolled with a simple remote controller.
Whatever your requirements may be,Mitsubishi Electric offers the perfectair conditioning solution for any situation.
Page 22
MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System
MSZ-GE-VA Inverter Heat Pump, Wall Mounted System
MSZ-FD-VA Inverter Heat Pump, Wall Mounted System
MFZ-KA-VA Inverter Heat Pump, Floor Mounted System
MXZ-C-VA Multi-Split Inverter Heat Pump
MXZ-8B-VA/YA Power Multi Inverter Heat Pump
Outdoor Units
M Series Accessories / Optional Extras
24
26
28
30
32
34
60
62
Contents
Page 23
Simple technologyat its best
Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
For further information please go to www.eca.gov.uk
MSZ-HC-VA(B) Inverter Heat Pump
Mitsubishi Electric’s range of high specification, flat panel wall mountedmodels make use of inverter technology, whilst providing extremely goodvalue for money, costing approximately 20% less than the MSZ-G equivalent.
These units have extremely quiet sound levels, whilst also deliveringeconomical air conditioning, with improved COP/EER figures and in many cases corresponding ‘A’ rated energy labels.
* Catechin filter is optional
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGY LABEL Heating/Cooling
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLY
PHASE
RUNNING CURRENT (A)
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
MSZ-HC-VA(B) - INDOOR UNITS
MSZ-HC25VA
3.2 (0.9-4.4)
2.5 (0.9-3.0)
2.65 (0.75-3.65)
2.5 (0.9-3.0)
0.79
3.64 / 3.25
A / A
5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5
9.52(3/8”)
6.35(1/4”)
26-32-38-43 / 26-32-38-43
788
225
295
9
Fed by Outdoor Unit
Single
0.22
6
4
MSZ-HC35VAB
3.6 (0.9-4.8)
3.4 (1.0-3.7)
3.0 (0.75-4.0)
3.35 (1.0-3.65)
0.76
3.62 / 3.01
A / B
4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2
9.52(3/8”)
6.35(1/4”)
26-32-38-43 / 26-32-38-43
788
225
295
9
Fed by Outdoor Unit
Single
0.22
6
4
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
MUZ-HC-VA(B) - OUTDOOR UNITS
MUZ-HC25VA
47 / 46
25
684
255
540
220-240v, 50Hz
Single
0.88 / 0.77
0.801 / 0.616
4.2
4.2 / 3.7 [5.5]
10
3
10
5
0.73
MUZ-HC35VAB
48 / 47
25
684
255
540
220-240v, 50Hz
Single
0.995 / 1.13
0.905 / 0.904
5.3
4.8 / 5.3 [6.5]
10
3
10
5
0.75
Technical Information
Page 24
Classic Wall Mounted System
MSZ
-HC
-VA
(B)
Inve
rter
Hea
t Pu
mp
INDOOR UNIT MSZ-HC25/35VA(B)
Upper View >
Front View > Side View >
M S
eri
es
Ran
ge
Dimensions
Page 25
76 843 181
325
65
67310
0
125
160
( 70∞)
238
5
184
12
Air out
Air in
1090 5
1100
MSZ
-GE-
VA
Inve
rter
Hea
t Pu
mp
INDOOR UNIT MSZ-GE22-50VA
INDOOR UNIT MSZ-GE60/71VA
Front View >
Side View >
Upper View >
Front View >
Side View >
Upper View >
Dimensions
Page 27
M S
eri
es
Ran
ge
MSZ-GE-VA - INDOOR UNITS
MSZ-GE-VA Inverter Heat Pump
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGY LABEL Heating/Cooling
AIRFLOW (m3/min) Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP
Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP
Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLY
PHASE
FUSE RATING (BS88) – HRC (A)
INTERCONNECTING CABLE No. CORES
MUZ-GE-VA - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
MSZ-GE60VA
6.8 (2.0-9.3)
6.0 (1.5-7.5)
5.65 (1.65-7.75)
5.95 (1.5-7.45)
0.79
3.84 / 3.40
A / A
9.8-11.3-13.4-15.6-18.3-20.7
9.8-11.3-13.4-15.6-18.3-20.7
15.88 (5/8”)
6.35 (1/4”)
29-37-41-45-49-52
29-37-41-45-49-52
1100
238
325
16
Fed by Outdoor Unit
Single
6
4
MSZ-GE71VA
8.1 (2.2-9.9)
7.1 (2.4-8.7)
6.75 (1.85-8.25)
7.05 (2.4-8.65)
0.78
3.83 / 3.33
A / A
10.2-11.5-13.3-15.4-17.8-19.4
9.7-11.5-13.3-15.4-17.8-19.4
15.88 (5/8”)
9.52 (3/8”)
30-37-41-45-49-52
30-37-41-45-49-53
1100
238
325
16
Fed by Outdoor Unit
Single
6
4
MSZ-GE50VA
5.8 (1.4-7.3)
5.0 (1.4-5.5)
4.8 (1.15-6.05)
4.95 (1.4-5.45)
0.76
3.71 / 3.30
A / A
6.5-7.8-9.6-12.2-14.5
6.5-7.8-9.6-11.9-15.1
12.7 (1/2”)
6.35 (1/4”)
28-33-37-43-48
28-33-38-44-49
798
232
295
10
Fed by Outdoor Unit
Single
6
4
MSZ-GE22VA
3.3 (0.9-4.0)
2.2 (0.9-3.0)
2.75 (0.75-3.3)
2.2 (0.9-3.0)
-
-
-
4.1-4.6-6.6-9.1-11.5
4.1-4.6-6.7-9.2-11.3
9.52 (3/8”)
6.35 (1/4”)
19-21-29-36-42
19-21-29-36-42
798
232
295
10
Fed by Outdoor Unit
Single
6
4
MSZ-GE25VA
3.2 (1.3-4.5)
2.5 (1.1-3.5)
2.65 (1.1-3.75)
2.5 (1.1-3.45)
0.96
4.57 / 4.59
A / A
4.1-4.8-6.6-9.1-11.5
4.1-4.8-6.7-9.1-11.3
9.52 (3/8”)
6.35 (1/4”)
19-21-29-36-42
19-21-29-36-42
798
232
295
10
Fed by Outdoor Unit
Single
6
4
MSZ-GE35VA
4.0 (1.6-5.3)
3.5 (1.1-4.0)
3.3 (1.35-4.4)
3.45 (1.1-3.95)
0.82
4.19 / 4.05
A / A
4.1-4.8-6.7-9.1-11.5
4.1-4.8-6.7-9.1-12.7
9.52 (3/8”)
6.35 (1/4”)
19-22-30-36-42
19-22-30-36-43
798
232
295
10
Fed by Outdoor Unit
Single
6
4
MUZ-GE60VA
55 / 55
50
840
330
880
220-240v, 50Hz
1.77 / 1.76
1.611 / 1.408
7.9
7.9 / 7.8 [14.5]
16
3
30
15
1.55
MUZ-GE71VA
55 / 55
53
840
330
880
220-240v, 50Hz
2.11 / 2.13
1.92 / 1.704
9.4
9.4 / 9.3 [16.6]
20
3
30
15
1.9
MUZ-GE50VA
56 / 54
54
840
330
850
220-240v, 50Hz
1.565 / 1.515
1.424 / 1.212
7.0
7.0 / 6.8 [13]
16
3
30
15
1.55
N/A Multi-Split Only
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MUZ-GE25VA
48 / 47
30
800
285
550
220-240v, 50Hz
0.70 / 0.545
0.637 / 0.436
3.7
3.7 / 2.9 [7.4]
10
3
20
12
0.8
MUZ-GE35VA
48 / 47
33
800
285
550
220-240v, 50Hz
0.955 / 0.865
0.869 / 0.692
4.6
4.6 / 4.2 [8.6]
10
3
20
12
1.15
Technical Information
Page 26
The MSZ series has been completely redesignedand features the new Nano Platinum filter system.
These models offer industry leading noise levels as low as 19dBA and have a distinctivelystyled front panel that not only looks appealing, but also helps to make cleaning of the unit easier.
Wall Mounted System
* Wide swing & long airflow mode available for MSZ-GE60/71VA * The anti-allergy enzyme filter is optional* Nano Platinum filter available for MSZ-GE60/71VA, Catechin filter available for MSZ-GE22-50VA
MSZ
-FD
-VA
Inve
rter
Hea
t Pu
mp
INDOOR UNIT MSZ-FD25/35VA
Front View > Side View >
Upper View >
Dimensions
Page 29
M S
eri
es
Ran
ge
MSZ-FD-VA - INDOOR UNITS
MSZ-FD-VA Inverter Heat Pump
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGY LABEL Heating/Cooling
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLY
PHASE
FUSE RATING (BS88) – HRC (A)
INTERCONNECTING CABLE No. CORES
MUZ-FD-VABH - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
MSZ-FD25VA3.2 (1.5-6.3)
2.5 (1.1-3.5)
2.65 (1.25-5.25)
2.5 (1.1-3.45)
0.85
5.33 / 5.15
A / A
4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2
9.52 (3/8”)
6.35 (1/4”)
20-29-36-43 / 20-29-36-42
798
257
295
12
Fed by Outdoor Unit
Single
6
4
MSZ-FD35VA4.0 (1.3-6.6)
3.5 (0.8-4.0)
3.3 (1.1-5.5)
3.45 (0.8-3.95)
0.85
4.76 / 4.19
A / A
4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2
9.52 (3/8”)
6.35 (1/4”)
21-29-36-44 / 21-29-36-43
798
257
295
12
Fed by Outdoor Unit
Single
6
4
MUZ-FD25VABH
46 / 46
36
800
285
550
220-240v, 50Hz
0.60 / 0.485
0.546 / 0.388
2.9
2.9 / 2.4 [10]
10
3
20
12
1.15
MUZ-FD35VABH
50 / 47
36
800
285
550
220-240v, 50Hz
0.84 / 0.835
0.764 / 0.668
3.9
3.9 / 3.8 [10.5]
16
3
20
12
1.15
Technical Information
Page 28
The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. They also offer industryleading noise levels and have a distinctively styled front panelthat not only looks appealing but also helps to make cleaningof the unit easier.
Also incorporated is an ‘I-See Sensor’, providingeven temperature distribution and furtherreducing energy consumption.
Wall Mounted System
MFZ
-KA
-VA
Inve
rter
Hea
t Pu
mp
INDOOR UNIT MFZ-KA25-50VA
Front View >
Upper View >
Side View >
Dimensions
Page 31
M S
eri
es
Ran
ge
MFZ-KA-VA - INDOOR UNITS
MFZ-KA-VA Inverter Heat Pump
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGY LABEL Heating/Cooling
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLY
PHASE
FUSE RATING (BS88) – HRC (A)
INTERCONNECTING CABLE No. CORES
SUZ-KA-VA2 - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
MFZ-KA25VA
3.4 (0.9-5.1)
2.5 (0.9-3.4)
2.85 (0.75-4.25)
2.5 (0.9-3.35)
0.66
4.07 / 4.31
A / A
5.0-6.2-7.6-9.4 / 4.8-5.8-7.1-8.9
9.52 (3/8”)
6.35 (1/4”)
22-27-32-37 / 22-27-32-37
700
200
600
14
Fed by Outdoor Unit
Single
6
4
MFZ-KA35VA
4.0 (0.9-6.2)
3.5 (0.9-3.9)
3.3 (0.75-5.15)
3.45 (0.9-3.85)
0.65
3.64 / 3.21
A / A
5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1
9.52 (3/8”)
6.35 (1/4”)
25-28-33-38 / 23-28-33-38
700
200
600
14
Fed by Outdoor Unit
Single
6
4
MFZ-KA50VA
6.0 (0.9-7.9)
4.8 (0.9-5.4)
5.0 (0.75-6.55)
4.75 (0.9-5.35)
0.63
3.23 / 3.10
C / B
7.4-8.8-9.8-12.3 / 7.1-7.9-9.2-11.2
12.7 (1/2”)
6.35 (1/4”)
32-35-39-44 / 32-35-39-43
700
200
600
14
Fed by Outdoor Unit
Single
6
4
SUZ-KA25VA2
46 / 46
33
800
285
550
220-240v, 50Hz
0.835 / 0.58
0.76 / 0.46
3.65
3.85 / 3.25 [8.4]
10
3
20
12
0.8
SUZ-KA35VA2
48 / 47
37
800
285
550
220-240v, 50Hz
1.10 / 1.09
1.00 / 0.87
4.75
4.95 / 4.75 [9.4]
10
3
20
12
1.05
SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
1.86 / 1.55
1.69 / 1.24
6.75
6.55 / 6.95 [16.2]
20
3
30
15
1.6
Technical Information
Page 30
The MFZ-KA-VA series is extremely versatileand is designed for wall attached installationat floor level. The auto swing vane providesa more natural and comfortable airflowthroughout the room and the lightweight, compact design makes installation easy.
Floor Mounted System
* The anti-allergy enzyme filter is optional
MX
Z-C
-VA
M
ulti-
Split
Inve
rter
Hea
t Pu
mp
(5.2
-12k
W)
OUTDOOR UNIT MXZ-2C52VA
Front View > Side View >Upper View >
Indoor and outdoor connect wiring 39 x 27 hole
27.1
23.1
440
45
315
84
299
360
710
840 30200
240
330 1330
66.3
D unit connection
C unit connection
B unit connection
A unit connection
Air in
Air in
Air out
(Bol
t Pitc
h)
171500
360.
6
20.3
13.3
16.8 31
.3
63.2 288233.1
169
396
17.7
17.7
OUTDOOR UNIT MXZ-3C54VA / MXZ-4C71VA
D connection for MXZ-4B71VA
460
317
900
900
23
597
132
405
45
Indoor and outdoorconnect wiring (35 x 53) hole
32030 10
88
D unit connectionE unit connection
C unit connectionB unit connection
A unit connection
Air out
3574
200 200500
35 250 270
355
(Bol
t pitc
h)38
7
4027 16
1611
24
Air in
Air in
OUTDOOR UNIT MXZ-4C80VA / MXZ-5C100VA
E connection for MXZ-5B100VA
Dimensions
Page 33
M S
eri
es
Ran
ge
Front View > Side View >Upper View >
Front View > Side View >Upper View >
OUTDOOR UNIT MXZ-6C120VA
Front View > Side View >Upper View >
MXZ-C-VA - OUTDOOR UNITS
MXZ-C-VA Inverter Heat Pump (5.2 - 12kW)
MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
COP / EER (nominal) Outdoor Only
ENERGy LABEL Heating/Cooling
MAX AIRFLOW (m3/min) Heating/Cooling
NOISE (dBA) Heating/Cooling - Sil-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [MAX] Heating/Cooling
INTERCONNECTING CABLE No. CORES
TOTAL PIPE LENGTH (m)
MAX PIPE LENGTH PER INDOOR UNIT (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) [Precharged Length]
FUSE RATING (BS88) – HRC (A)
MXZ-3C54VA
2 - 3
7.0 (2.6-9.0)
5.4 (2.9-6.8)
5.8 (2.15-7.5)
5.35 (2.9-6.75)
5.04 / 4.23
A / A
43 / 42.1
48-51 / 45-47
840
330
710
57
220-240v, 50Hz
1.465 / 1.19
1.33 / 0.95
6.43
6.43 / 5.23 [15]
4 Core
50
25
15 (10 if OU higher than IU)
2.7 [40m]
25
MXZ-4C71VA
2 - 4
8.6 (3.4-10.7)
7.1 (3.7-8.8)
7.15 (2.85-8.9)
7.05 (3.65-8.75)
4.78 / 4.54
A / A
43 / 42.1
48-52 / 45-48
840
330
710
58
220-240v, 50Hz
1.705 / 1.68
1.55 / 1.34
7.49
7.49 / 7.38 [15]
4 Core
60
25
15 (10 if OU higher than IU)
2.7 [40m]
25
MXZ-5C100VA
2 - 5
12.0 (4.1-14.0)
10.0 (3.9-11.0)
9.95 (3.4-11.65)
9.9 (3.85-10.9)
4.23 / 3.57
A / A
59.3 / 56.6
47-54 / 46-51
900
320
900
68
220-240v, 50Hz
2.835 / 2.88
2.58 / 2.30
12.45
12.45 / 12.30 [18.4]
4 Core
80
25
15 (10 if OU higher than IU)
4.0 [40m]
25
MXZ-6C120VA
2 - 6
14.0 (3.5-16.5)
12.0 (3.5-13.5)
11.65 (2.9-13.7)
11.9 (3.45-13.4)
3.88 / 3.21
A / A
59.5 / 69.9
53-57 / 51-55
900
320
1070
88
220-240v, 50Hz
3.47 / 3.61
3.16 / 2.89
15.85
15.24 / 15.85 [27]
4 Core
80
25
15 (10 if OU higher than IU)
5.0 [60m]
40
MXZ-2C52VA
2
6.4 (1.0-7.0)
5.2 (1.1-6.0)
5.3 (0.85-5.8)
5.15 (1.1-5.95)
3.98 / 4.00
A / A
33.3 / 32.9
49-50 / 46-49
800
285
550
38
220-240v, 50Hz
1.61 / 1.30
1.47 / 1.04
7.22
7.22 / 5.83 [10.2]
4 Core
30
20
15 (10 if OU higher than IU)
1.3 [20m]
16
MXZ-4C80VA
2 - 4
9.4 (3.4-11.6)
8.0 (3.7-9.2)
7.8 (2.85-9.65)
7.95 (3.65-9.15)
4.87 / 4.09
A / A
43.8 / 42.2
46-48 / 44-46
900
320
900
67
220-240v, 50Hz
1.93 / 1.955
1.76 / 1.56
8.59
8.48 / 8.59 [17.4]
4 Core
70
25
15 (10 if OU higher than IU)
3.5 [40m]
25
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE
MSZ-GE22/25/35/50VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50VAQ
PEAD-RP50JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP50BAMXZ-3C54VA
MSZ-GE22/25/35VAMSZ-FD25/35VAMSZ-EF25/35VEB
MFZ-KA25/35VA SEZ-KD25/35VAQ SLZ-KA25/35VAQ -MXZ-2C52VA
MFZ-KA25/35/50VASEZ-KD25/35/50/60VAQ
PEAD-RP50JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP50/60BAMXZ-4C71VA
MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA(2)MXZ-4C80VA
MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA(2)MXZ-5C100VA
MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA(2)MXZ-6C120VA
WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE
PCA-RP50KAQ
PCA-RP50/60KAQ
PCA-RP50/60/71KAQ
PCA-RP50/60/71KAQ
PCA-RP50/60/71KAQ
CEILING SUSPENDED
� Up to six indoor units may be connected to a single outdoor unit
� Energy saving inverter controlled outdoor unit adjusts compressorperformance to economically match the demand for heating and cooling
� Units may be added within the capacity of the system as requirements change
� Capacities of indoor units may be mixed to suit individual rooms
� New size 80, 100 and 120 have current limit adjustment for managingenergy costs. They also feature a wiring/piping correction function toanalyse the system for connection errors via the press of a single button
Technical Information
Page 32
The multi-split system allows up to six M Series or Mr Slim wall mounted,cassette, ducted, floor or ceiling mounted indoor unit heat pumps of differentcapacities to be operated from a single outdoor unit. This makes it an economicanswer in multi-room applications, whilst also offering space saving benefits.
Multi-Split Units
MSZ-GE22/25/35/50/60VAMSZ-FD25/35VA
MSZ-EF25/35/50VEB
*1 Combined max running current of all indoors on system must not exceed 3A if PEAD-RP is used
MX
Z-8
B-V
A/Y
APower M
ulti Inverter H
eat Pump (14-15.5kW
)
OUTDOOR UNIT MXZ-8B140VA / MXZ-8B160YA
Front View > Side View >
Front View > Side View >
Upper View >
to indoor unit55
198 65
39
25 25 25 25 25 21
75 75 75 75
E D C B A
E D C B A
91
73
450 95 280 39
61 79 50 34
7035
68
320
402
24
12
Upper View >
Front View > Side View >
205
198 65
39
25 25 25 21
75 75
91
73
C B A
C B A
450
to indoor unit
95
61 79 50 34
39280
7035
68
320
402
24
12
Upper View >
BRANCH BOX PAC-AK31BC
BRANCH BOX PAC-AK52BC
Dimensions
Page 35
M S
eri
esRange
MXZ-8B-VA/YA - OUTDOOR UNITS
MXZ-8B-VA/YA Power Multi (14-15.5kW)
MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
COP / EER (nominal) Outdoor Only
ENERGY LABEL Heating/Cooling
MAX AIRFLOW (m3/min)
NOISE (dBA) Heating/Cooling - Sil-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLY
PHASE
POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [MAX] Heating/Cooling
INTERCONNECTING CABLE No. CORES
TOTAL PIPE LENGTH (m)
MAX PIPE LENGTH PER INDOOR UNIT (m)
FURTHEST PIPE LENGTH - Outdoor to Indoor (m)
MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)
MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)
CHARGE R410A (kg) - 40m
FUSE RATING (BS88) – HRC (A)
MXZ-8B140VA
2 - 8
16.0
14.0
13.3
13.9
3.91 / 3.52
A / A
100
52 / 47-50
950
330
1350
129
220-240v, 50Hz
Single
3.90 / 3.79
3.55 / 3.03
14
17.05 / 16.55 [29.5]
4 Core
115
15 (from Branch Box)
70
30 (20 if OU lower than IU)
12
8.5
40
PAC-AK31BC
1 - 3
From Outdoor Unit
From Branch Box
15.88(5/8”)
9.52(3/8”)
55
60
30
15
450
280
198
PAC-AK31BC - BRANCH BOX
MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS
POWER SUPPLY TO BRANCH BOX
POWER SUPPLY TO INDOOR UNITS
PIPE SIZE mm(in) Main Outdoor Side - Gas
PIPE SIZE mm(in) Main Outdoor Side - Liquid
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
DIMENSIONS (mm) Width
Depth
Height
PAC-AK52BC
1 - 5
From Outdoor Unit
From Branch Box
15.88(5/8”)
9.52(3/8”)
55
60
30
15
450
280
198
PAC-AK52BC - BRANCH BOX
MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS
POWER SUPPLY TO BRANCH BOX
POWER SUPPLY TO INDOOR UNITS
PIPE SIZE mm(in) Main Outdoor Side - Gas
PIPE SIZE mm(in) Main Outdoor Side - Liquid
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
DIMENSIONS (mm) Width
Depth
Height
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE
MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP35/50/60/71BA(2)
PLA-RP100BA(3)*2
MXZ-8B140VA
MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA
MSZ-EF25/35/50VEBMFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ
PLA-RP35/50/60/71BA(2)
PLA-RP100BA(3)*2
MXZ-8B160YA
WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE
� 14 and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology
� Total Pipe length of 115m / Height difference of 30m
� Individual control of each indoor unit is now possible (ON/OFF & Setpoint)
� Low starting and running currents
� Connection to M-NET system via MAC-399IF interface (one per indoor unit)
� Current limit adjustment for managing energy costs
Technical Information
Page 34
The Power Multi systems allow up to eight M Series or Mr Slim cassette, ducted,floor, ceiling or wall mounted indoor units of different capacities to be operatedfrom a single outdoor unit, making use of two types of branch box to achieve this.This makes them an economic answer in multi-room applications and ideal forapartments or small commercial buildings.
Inverter Heat Pump Multi-Split Units
*1Total capacity of indoor units must not exceed 100% if PEAD-RP is used *2 Can only be connected using a PAC-AK52BC with a PAC-AK52YP-E pipe
MXZ-8B160YA
2 - 8
18.0
15.5
14.95
15.4
3.61 / 3.21
A / A
106
54 / 48-51
950
330
1350
139
380-415v, 50Hz
3
4.80 / 4.64
4.37 / 3.71
7
7.00 / 6.77 [13]
4 Core
115
15 (from Branch Box)
70
30 (20 if OU lower than IU)
12
8.5
25
MXZ-8B140VAMXZ-8B160YAPower Multi units
MXZ-4C80VAMXZ-5C100VAInverter Multi units
MXZ-6C120VAInverter Multi unit
MXZ-3C54VAMXZ-4C71VAInverter Multi units
Page 36
Multi-Split Systems8 Outdoor Units 32 Indoor Units
MXZ-2C52VAInverter Multi unit
PCA-RP-KAQ Series
PEAD-RP-JAQ Series
SEZ-KD-VAQ Series
SLZ-KA-VAQ Series
PLA-RP-BA(2)(3) Series
MFZ-KA-VA Series
MSZ-FD-VA Series
MSZ-GE-VA Series
Multi-Split systems allow upto eight M Series or Mr Slim cassette, ducted, floor, ceilingor wall mounted indoor unitsof different capacitiesto be operated froma single outdoor unit.
Page 37
1 ROOM22
25
35
50
60
71
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
22 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
2.20 / 3.30
2.20 / 3.23
2.20 / 2.89
2.20 / 2.51
2.09 / 2.52
1.87 / 2.22
2.50 / 3.60
2.50 / 3.17
2.50 / 2.87
2.29 / 2.76
2.06 / 2.45
3.50 / 4.00
3.21 / 3.87
Unit B
2.20 / 3.30
2.50 / 3.67
3.50 / 4.61
5.00 / 5.69
5.71 / 6.88
6.03 / 7.18
2.50 / 3.60
3.50 / 4.43
5.00 / 5.73
5.51 / 6.64
5.84 / 6.95
3.50 / 4.00
4.59 / 5.53
Unit C Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
MXZ-4C80VA1Outdoor Unit Up to 4 Indoor Units
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
3 ROOMS
22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 22 + 71
22 + 25 + 25
22 + 25 + 35
22 + 25 + 50
22 + 25 + 60
22 + 25 + 71
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 35 + 71
22 + 50 + 50
22 + 50 + 60
22 + 50 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
Unit A
2.91 / 3.46
2.61 / 3.10
3.95 / 4.70
3.64 / 4.27
3.31 / 3.88
4.00 / 4.70
3.66 / 4.31
2.20 / 2.90
2.20 / 2.81
2.14 / 2.56
1.83 / 2.20
1.67 / 1.99
1.53 / 1.80
2.20 / 2.72
2.07 / 2.50
1.79 / 2.13
1.64 / 1.93
1.49 / 1.75
1.87 / 2.25
1.64 / 1.93
1.50 / 1.77
1.38 / 1.62
1.44 / 1.70
1.33 / 1.57
1.23 / 1.45
2.50 / 3.00
2.29 / 2.76
1.98 / 2.35
1.82 / 2.14
1.65 / 1.94
2.08 / 2.47
1.82 / 2.14
1.67 / 1.96
1.53 / 1.79
1.60 / 1.88
1.48 / 1.74
2.65 / 3.13
2.33 / 2.74
2.15 / 2.53
1.99 / 2.33
2.07 / 2.44
1.93 / 2.27
Unit B
4.99 / 5.94
5.29 / 6.30
3.95 / 4.70
4.36 / 5.13
4.69 / 5.52
4.00 / 4.70
4.34 / 5.09
2.20 / 2.90
2.20 / 2.81
2.14 / 2.56
1.83 / 2.20
1.67 / 1.99
1.53 / 1.80
2.50 / 3.09
2.35 / 2.84
2.04 / 2.42
1.87 / 2.20
1.69 / 1.99
2.97 / 3.58
2.62 / 3.07
2.39 / 2.81
2.19 / 2.57
3.28 / 3.85
3.03 / 3.56
2.80 / 3.29
2.50 / 3.00
2.29 / 2.76
1.98 / 2.35
1.82 / 2.14
1.65 / 1.94
2.91 / 3.46
2.55 / 2.99
2.33 / 2.74
2.14 / 2.51
3.20 / 3.76
2.96 / 3.48
2.65 / 3.13
2.33 / 2.74
2.15 / 2.53
1.99 / 2.33
2.96 / 3.48
2.76 / 3.24
Unit C
2.20 / 2.90
2.50 / 3.19
3.41 / 4.08
4.15 / 5.00
4.56 / 5.42
4.94 / 5.80
2.50 / 3.09
3.29 / 3.97
4.07 / 4.85
4.49 / 5.27
4.81 / 5.66
2.97 / 3.58
3.74 / 4.39
4.10 / 4.82
4.44 / 5.21
3.28 / 3.85
3.64 / 4.27
3.97 / 4.67
2.50 / 3.00
3.21 / 3.87
3.95 / 4.70
4.36 / 5.13
4.69 / 5.52
2.91 / 3.46
3.64 / 4.27
4.00 / 4.70
4.34 / 5.09
3.20 / 3.76
3.56 / 4.18
2.65 / 3.13
3.33 / 3.92
3.69 / 4.34
4.03 / 4.73
2.96 / 3.48
3.31 / 3.89
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
4 ROOMS22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 35 + 35
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 35 + 35
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 35 + 35
Unit A
1.78 / 2.15
1.72 / 2.08
1.55 / 1.87
1.35 / 1.63
1.66 / 2.01
1.50 / 1.82
1.31 / 1.59
1.37 / 1.66
1.61 / 1.95
1.46 / 1.77
1.28 / 1.55
1.34 / 1.62
1.78 / 2.15
1.61 / 1.95
1.42 / 1.72
1.48 / 1.79
Unit B
1.78 / 2.15
1.72 / 2.08
1.55 / 1.87
1.35 / 1.63
1.66 / 2.01
1.50 / 1.82
1.31 / 1.59
1.37 / 1.66
1.83 / 2.22
1.66 / 2.01
1.45 / 1.76
1.52 / 1.84
1.78 / 2.15
1.61 / 1.95
1.42 / 1.72
1.48 / 1.79
Unit C
1.78 / 2.15
1.72 / 2.08
1.55 / 1.87
1.35 / 1.63
1.89 / 2.29
1.71 / 2.07
1.49 / 1.81
2.18 / 2.64
1.83 / 2.22
1.66 / 2.01
1.45 / 1.76
2.12 / 2.57
1.78 / 2.15
1.61 / 1.95
1.42 / 1.72
2.07 / 2.51
Unit D
1.78 / 2.15
1.95 / 2.36
2.46 / 2.98
3.06 / 3.71
1.89 / 2.29
2.39 / 2.89
2.98 / 3.61
2.18 / 2.64
1.83 / 2.22
2.32 / 2.81
2.91 / 3.52
2.12 / 2.57
1.78 / 2.15
2.26 / 2.74
2.84 / 3.44
2.07 / 2.51
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 39
1 ROOM22
25
35
2 ROOMS22 + 22
22 + 25
22 + 35
25 + 25
25 + 35
35 + 35
Indoor unitcombination
Cooling / Heating Capacity (kW)
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
2.20 / 3.05
2.20 / 2.90
1.93 / 2.43
2.50 / 3.15
2.13 / 2.63
2.60 / 3.20
Unit B
2.20 / 3.05
2.50 / 3.30
3.07 / 3.87
2.50 / 3.15
2.98 / 3.68
2.60 / 3.20
MXZ-2C52VA1Outdoor Unit 2 Indoor Units
MXZ-4C71VA1Outdoor Unit Up to 4 Indoor Units
1 ROOM22
25
35
50
60
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
25 + 25
25 + 35
25 + 50
25 + 60
35 + 35
35 + 50
35 + 60
50 + 50
50 + 60
60 + 60
3 ROOMS22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 25 + 25
22 + 25 + 35
22 + 25 + 50
22 + 25 + 60
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 50 + 50
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 50 + 50
35 + 35 + 35
35 + 35 + 50
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
2.20 / 3.30
2.20 / 3.23
2.20 / 2.97
2.08 / 2.63
1.82 / 2.31
2.50 / 3.60
2.50 / 3.29
2.27 / 2.87
2.00 / 2.53
3.40 / 4.30
2.80 / 3.54
2.51 / 3.17
3.40 / 4.30
3.09 / 3.91
3.40 / 4.30
2.20 / 2.87
2.20 / 2.74
1.98 / 2.39
1.66 / 2.01
1.50 / 1.82
2.17 / 2.63
1.90 / 2.31
1.61 / 1.95
1.46 / 1.77
1.70 / 2.06
1.46 / 1.77
1.34 / 1.62
1.28 / 1.55
2.37 / 2.87
2.09 / 2.53
1.78 / 2.15
1.61 / 1.95
1.87 / 2.26
1.61 / 1.95
1.48 / 1.79
1.42 / 1.72
2.37 / 2.87
2.07 / 2.51
Unit B
2.20 / 3.30
2.50 / 3.67
3.50 / 4.73
4.72 / 5.97
4.98 / 6.29
2.50 / 3.60
3.50 / 4.61
4.53 / 5.73
4.80 / 6.07
3.40 / 4.30
4.00 / 5.06
4.29 / 5.43
3.40 / 4.30
3.71 / 4.69
3.40 / 4.30
2.20 / 2.87
2.20 / 2.74
1.98 / 2.39
1.66 / 2.01
1.50 / 1.82
2.47 / 2.99
2.16 / 2.62
1.83 / 2.22
1.66 / 2.01
2.70 / 3.27
2.32 / 2.81
2.12 / 2.57
2.91 / 3.52
2.37 / 2.87
2.09 / 2.53
1.78 / 2.15
1.61 / 1.95
2.62 / 3.17
2.26 / 2.74
2.07 / 2.51
2.84 / 3.44
2.37 / 2.87
2.07 / 2.51
Unit C
2.20 / 2.87
2.50 / 3.12
3.15 / 3.81
3.78 / 4.57
4.10 / 4.96
2.47 / 2.99
3.03 / 3.67
3.66 / 4.43
3.98 / 4.82
2.70 / 3.27
3.32 / 4.02
3.64 / 4.41
2.91 / 3.52
2.37 / 2.87
2.92 / 3.54
3.55 / 4.30
3.87 / 4.69
2.62 / 3.17
3.23 / 3.91
3.55 / 4.30
2.84 / 3.44
2.37 / 2.87
2.96 / 3.58
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
Multi-Split System Combinations
1 ROOM22
25
35
50
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
25 + 25
25 + 35
25 + 50
35 + 35
35 + 50
50 + 50
3 ROOMS22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 25 + 25
22 + 25 + 35
22 + 25 + 50
22 + 35 + 35
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 35 + 35
Indoor unitcombination
Cooling / Heating Capacity (kW)
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 6.80
2.20 / 3.30
2.20 / 3.14
2.08 / 2.62
1.65 / 2.08
2.50 / 3.40
2.25 / 2.83
1.80 / 2.27
2.70 / 3.40
2.22 / 2.80
2.70 / 3.40
1.80 / 2.27
1.72 / 2.20
1.50 / 1.95
1.26 / 1.64
1.65 / 2.11
1.45 / 1.88
1.22 / 1.59
1.29 / 1.67
1.80 / 2.33
1.59 / 2.06
1.35 / 1.75
1.42 / 1.84
Unit B
2.20 / 3.30
2.50 / 3.56
3.32 / 4.18
3.75 / 4.72
2.50 / 3.40
3.15 / 3.97
3.60 / 4.53
2.70 / 3.40
3.18 / 4.00
2.70 / 3.40
1.80 / 2.27
1.72 / 2.20
1.50 / 1.95
1.26 / 1.64
1.88 / 2.40
1.65 / 2.13
1.39 / 1.80
2.05 / 2.66
1.80 / 2.33
1.59 / 2.06
1.35 / 1.75
1.99 / 2.58
Unit C
1.80 / 2.27
1.96 / 2.50
2.39 / 3.10
2.87 / 3.72
1.88 / 2.40
2.30 / 2.99
2.78 / 3.61
2.05 / 2.66
1.80 / 2.33
2.22 / 2.88
2.70 / 3.50
1.99 / 2.58
MXZ-3C54VA1Outdoor Unit Up to 3 Indoor Units
Page 38
22 + 22 + 35 + 71
22 + 22 + 50 + 50
22 + 22 + 50 + 60
22 + 22 + 50 + 71
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 25 + 60
22 + 25 + 25 + 71
22 + 25 + 35 + 35
22 + 25 + 35 + 50
22 + 25 + 35 + 60
22 + 25 + 35 + 71
22 + 25 + 50 + 50
22 + 25 + 50 + 60
22 + 25 + 50 + 71
22 + 35 + 35 + 35
22 + 35 + 35 + 50
22 + 35 + 35 + 60
22 + 35 + 35 + 71
22 + 35 + 50 + 50
22 + 35 + 50 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
Unit A
1.39 / 1.61
1.45 / 1.68
1.37 / 1.57
1.31 / 1.47
1.93 / 2.27
1.79 / 2.10
1.62 / 1.91
1.53 / 1.80
1.45 / 1.69
1.67 / 1.96
1.53 / 1.80
1.46 / 1.70
1.38 / 1.58
1.42 / 1.65
1.35 / 1.54
1.28 / 1.44
1.58 / 1.85
1.46 / 1.70
1.39 / 1.59
1.31 / 1.48
1.35 / 1.54
1.29 / 1.45
2.15 / 2.50
2.00 / 2.34
1.82 / 2.12
1.72 / 2.02
1.63 / 1.88
1.88 / 2.19
1.72 / 2.02
1.64 / 1.90
1.54 / 1.76
1.58 / 1.83
1.52 / 1.72
1.43 / 1.61
1.77 / 2.08
1.64 / 1.90
1.55 / 1.77
1.48 / 1.66
2.35 / 2.75
2.17 / 2.48
2.08 / 2.33
Unit B
1.39 / 1.61
1.45 / 1.68
1.37 / 1.57
1.31 / 1.47
2.19 / 2.58
2.03 / 2.38
1.84 / 2.17
1.74 / 2.05
1.64 / 1.92
1.90 / 2.22
1.74 / 2.05
1.65 / 1.94
1.57 / 1.80
1.62 / 1.87
1.53 / 1.75
1.46 / 1.64
2.51 / 2.95
2.32 / 2.71
2.21 / 2.53
2.08 / 2.36
2.14 / 2.45
2.05 / 2.31
2.15 / 2.50
2.00 / 2.34
1.82 / 2.12
1.72 / 2.02
1.63 / 1.88
1.88 / 2.19
1.72 / 2.02
1.64 / 1.90
1.54 / 1.76
1.58 / 1.83
1.52 / 1.72
1.43 / 1.61
2.48 / 2.91
2.29 / 2.66
2.17 / 2.48
2.07 / 2.32
2.35 / 2.75
2.17 / 2.48
2.08 / 2.33
Unit C
2.22 / 2.57
3.30 / 3.82
3.12 / 3.57
2.97 / 3.33
2.19 / 2.58
2.03 / 2.38
1.84 / 2.17
1.74 / 2.05
1.64 / 1.92
2.66 / 3.11
2.44 / 2.86
2.32 / 2.71
2.20 / 2.52
3.23 / 3.74
3.06 / 3.50
2.92 / 3.27
2.51 / 2.95
2.32 / 2.71
2.21 / 2.53
2.08 / 2.36
3.06 / 3.50
2.93 / 3.29
2.15 / 2.50
2.00 / 2.34
1.82 / 2.12
1.72 / 2.02
1.63 / 1.88
2.63 / 3.06
2.41 / 2.83
2.29 / 2.66
2.15 / 2.47
3.17 / 3.67
3.03 / 3.44
2.87 / 3.22
2.48 / 2.91
2.29 / 2.66
2.17 / 2.48
2.07 / 2.32
2.35 / 2.75
2.17 / 2.48
2.08 / 2.33
Unit D
4.50 / 5.21
3.30 / 3.82
3.74 / 4.29
4.22 / 4.73
2.19 / 2.58
2.85 / 3.34
3.69 / 4.34
4.18 / 4.91
4.67 / 5.46
2.66 / 3.11
3.48 / 4.09
3.97 / 4.65
4.45 / 5.10
3.23 / 3.74
3.67 / 4.20
4.14 / 4.65
2.51 / 2.95
3.31 / 3.87
3.79 / 4.34
4.23 / 4.79
3.06 / 3.50
3.52 / 3.95
2.15 / 2.50
2.80 / 3.28
3.64 / 4.24
4.13 / 4.84
4.62 / 5.35
2.63 / 3.06
3.44 / 4.04
3.93 / 4.54
4.37 / 5.01
3.17 / 3.67
3.64 / 4.13
4.07 / 4.57
2.48 / 2.91
3.28 / 3.79
3.72 / 4.26
4.19 / 4.70
2.35 / 2.75
3.10 / 3.55
3.56 / 4.00
Indoor unitcombination
Cooling / Heating Capacity (kW)
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 60 + 60
25 + 60 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 60 + 60
35 + 60 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
4 ROOMS
22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 22 + 60
22 + 22 + 22 + 71
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 25 + 60
22 + 22 + 25 + 71
22 + 22 + 35 + 35
22 + 22 + 35 + 50
22 + 22 + 35 + 60
Unit A
2.50 / 3.00
2.32 / 2.74
2.10 / 2.45
1.98 / 2.32
1.84 / 2.19
2.16 / 2.55
1.98 / 2.32
1.85 / 2.21
1.74 / 2.06
1.80 / 2.16
1.70 / 2.02
1.59 / 1.88
1.60 / 1.90
1.51 / 1.76
2.87 / 3.33
2.60 / 3.09
2.45 / 2.91
2.31 / 2.71
2.39 / 2.83
2.24 / 2.66
2.11 / 2.47
2.12 / 2.48
1.98 / 2.32
3.13 / 3.67
2.94 / 3.44
2.75 / 3.22
2.00 / 2.50
1.98 / 2.42
1.87 / 2.18
1.69 / 1.97
1.59 / 1.87
1.49 / 1.75
1.94 / 2.34
1.84 / 2.14
1.66 / 1.94
1.57 / 1.82
1.48 / 1.73
1.72 / 2.01
1.57 / 1.82
1.49 / 1.74
Unit B
2.50 / 3.00
2.32 / 2.74
2.10 / 2.45
1.98 / 2.32
1.84 / 2.19
3.02 / 3.57
2.77 / 3.25
2.60 / 3.09
2.43 / 2.89
3.60 / 4.32
3.41 / 4.04
3.18 / 3.77
3.85 / 4.55
3.62 / 4.23
2.87 / 3.33
2.60 / 3.09
2.45 / 2.91
2.31 / 2.71
3.41 / 4.04
3.21 / 3.79
3.01 / 3.53
3.64 / 4.26
3.40 / 3.98
3.13 / 3.67
2.94 / 3.44
2.75 / 3.22
2.00 / 2.50
1.98 / 2.42
1.87 / 2.18
1.69 / 1.97
1.59 / 1.87
1.49 / 1.75
1.94 / 2.34
1.84 / 2.14
1.66 / 1.94
1.57 / 1.82
1.48 / 1.73
1.72 / 2.01
1.57 / 1.82
1.49 / 1.74
Unit C
2.50 / 3.00
3.25 / 3.83
4.20 / 4.90
4.75 / 5.56
5.22 / 6.22
3.02 / 3.57
3.95 / 4.64
4.45 / 5.30
4.93 / 5.85
3.60 / 4.32
4.09 / 4.84
4.52 / 5.35
3.85 / 4.55
4.28 / 5.01
2.87 / 3.33
3.71 / 4.42
4.20 / 4.98
4.68 / 5.49
3.41 / 4.04
3.85 / 4.55
4.28 / 5.01
3.64 / 4.26
4.02 / 4.70
3.13 / 3.67
3.53 / 4.13
3.90 / 4.57
2.00 / 2.50
1.98 / 2.42
1.87 / 2.18
1.69 / 1.97
1.59 / 1.87
1.49 / 1.75
2.21 / 2.66
2.09 / 2.43
1.89 / 2.21
1.78 / 2.07
1.68 / 1.96
2.73 / 3.19
2.50 / 2.90
2.37 / 2.77
Unit D
2.00 / 2.50
2.25 / 2.75
2.98 / 3.47
3.84 / 4.48
4.33 / 5.10
4.82 / 5.65
2.21 / 2.66
2.93 / 3.40
3.78 / 4.41
4.28 / 4.98
4.77 / 5.58
2.73 / 3.19
3.57 / 4.15
4.06 / 4.75
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 41
4 ROOMS22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 22 + 60
22 + 22 + 22 + 71
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 25 + 60
22 + 22 + 25 + 71
22 + 22 + 35 + 35
22 + 22 + 35 + 50
22 + 22 + 35 + 60
22 + 22 + 50 + 50
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 25 + 60
22 + 25 + 35 + 35
22 + 25 + 35 + 50
22 + 25 + 35 + 60
22 + 35 + 35 + 35
22 + 35 + 35 + 50
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 35 + 35 + 35
35 + 35 + 35 + 35
Unit A
1.95 / 2.35
1.90 / 2.27
1.73 / 2.05
1.52 / 1.78
1.40 / 1.64
1.28 / 1.51
1.84 / 2.20
1.68 / 1.99
1.48 / 1.74
1.36 / 1.60
1.26 / 1.48
1.54 / 1.81
1.36 / 1.60
1.27 / 1.49
1.22 / 1.44
1.79 / 2.13
1.63 / 1.93
1.44 / 1.70
1.33 / 1.57
1.50 / 1.77
1.33 / 1.57
1.24 / 1.46
1.39 / 1.63
1.24 / 1.45
1.98 / 2.35
1.82 / 2.14
1.60 / 1.88
1.48 / 1.74
1.67 / 1.96
1.48 / 1.74
1.54 / 1.81
2.00 / 2.35
Unit B
1.95 / 2.35
1.90 / 2.27
1.73 / 2.05
1.52 / 1.78
1.40 / 1.64
1.28 / 1.51
1.84 / 2.20
1.68 / 1.99
1.48 / 1.74
1.36 / 1.60
1.26 / 1.48
1.54 / 1.81
1.36 / 1.60
1.27 / 1.49
1.22 / 1.44
2.04 / 2.42
1.86 / 2.20
1.64 / 1.93
1.52 / 1.78
1.71 / 2.01
1.52 / 1.78
1.41 / 1.65
2.20 / 2.59
1.97 / 2.32
1.98 / 2.35
1.82 / 2.14
1.60 / 1.88
1.48 / 1.74
1.67 / 1.96
1.48 / 1.74
2.15 / 2.53
2.00 / 2.35
Unit C
1.95 / 2.35
1.90 / 2.27
1.73 / 2.05
1.52 / 1.78
1.40 / 1.64
1.28 / 1.51
2.09 / 2.50
1.91 / 2.26
1.68 / 1.97
1.55 / 1.82
1.43 / 1.68
2.46 / 2.89
2.17 / 2.55
2.01 / 2.37
2.78 / 3.26
2.04 / 2.42
1.86 / 2.20
1.64 / 1.93
1.52 / 1.78
2.39 / 2.81
2.12 / 2.49
1.97 / 2.32
2.20 / 2.59
1.97 / 2.32
1.98 / 2.35
1.82 / 2.14
1.60 / 1.88
1.48 / 1.74
2.33 / 2.74
2.07 / 2.44
2.15 / 2.53
2.00 / 2.35
Unit D
1.95 / 2.35
2.16 / 2.58
2.75 / 3.26
3.45 / 4.05
3.81 / 4.48
4.15 / 4.87
2.09 / 2.50
2.68 / 3.16
3.36 / 3.95
3.72 / 4.37
4.06 / 4.77
2.46 / 2.89
3.10 / 3.64
3.45 / 4.06
2.78 / 3.26
2.04 / 2.42
2.60 / 3.07
3.28 / 3.85
3.64 / 4.27
2.39 / 2.81
3.03 / 3.56
3.38 / 3.97
2.20 / 2.59
2.82 / 3.31
1.98 / 2.35
2.55 / 2.99
3.20 / 3.76
3.56 / 4.18
2.33 / 2.74
2.96 / 3.48
2.15 / 2.53
2.00 / 2.35
Indoor unitcombination
Cooling / Heating Capacity (kW)
1 ROOM22
25
35
50
60
71
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
Unit B Unit C Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
MXZ-5C100VA1Outdoor Unit Up to 5 Indoor Units
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
22 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
71 + 71
3 ROOMS
22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 22 + 71
22 + 25 + 25
22 + 25 + 35
22 + 25 + 50
22 + 25 + 60
22 + 25 + 71
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 35 + 71
22 + 50 + 50
22 + 50 + 60
22 + 50 + 71
22 + 60 + 60
22 + 60 + 71
Unit A
2.20 / 3.30
2.20 / 3.23
2.20 / 2.89
2.17 / 2.57
2.07 / 2.71
1.92 / 2.51
2.50 / 3.60
2.50 / 3.17
2.43 / 2.97
2.29 / 3.09
2.14 / 2.76
3.50 / 4.00
3.21 / 4.32
2.98 / 3.91
2.81 / 3.50
4.15 / 5.30
3.91 / 4.82
3.68 / 4.38
4.45 / 5.30
4.12 / 4.85
4.55 / 5.30
2.20 / 2.90
2.20 / 2.81
2.12 / 2.53
1.92 / 2.25
1.82 / 2.12
1.68 / 1.99
2.20 / 2.72
2.09 / 2.47
1.88 / 2.20
1.77 / 2.08
1.64 / 1.96
1.94 / 2.30
1.77 / 2.08
1.65 / 1.97
1.55 / 1.86
1.60 / 1.91
1.52 / 1.82
1.43 / 1.68
1.44 / 1.69
1.35 / 1.58
Unit B
2.20 / 3.30
2.50 / 3.67
3.50 / 4.61
4.93 / 5.83
5.63 / 7.39
6.18 / 8.09
2.50 / 3.60
3.50 / 4.43
4.87 / 5.93
5.51 / 7.41
6.06 / 7.84
3.50 / 4.00
4.59 / 6.18
5.12 / 6.69
5.69 / 7.10
4.15 / 5.30
4.69 / 5.78
5.22 / 6.22
4.45 / 5.30
4.88 / 5.75
4.55 / 5.30
2.20 / 2.90
2.20 / 2.81
2.12 / 2.53
1.92 / 2.25
1.82 / 2.12
1.68 / 1.99
2.50 / 3.09
2.38 / 2.80
2.14 / 2.50
2.01 / 2.36
1.86 / 2.22
3.08 / 3.65
2.81 / 3.30
2.63 / 3.14
2.46 / 2.95
3.65 / 4.34
3.45 / 4.13
3.25 / 3.81
3.93 / 4.61
3.69 / 4.31
Unit C
2.20 / 2.90
2.50 / 3.19
3.37 / 4.03
4.36 / 5.11
4.96 / 5.77
5.43 / 6.42
2.50 / 3.09
3.33 / 3.93
4.28 / 5.00
4.82 / 5.66
5.29 / 6.32
3.08 / 3.65
4.02 / 4.72
4.51 / 5.38
4.99 / 5.99
3.65 / 4.34
4.14 / 4.95
4.62 / 5.41
3.93 / 4.61
4.36 / 5.10
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 40
1 ROOM
22
25
35
50
60
71
2 ROOMS
22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
22 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
71 + 71
3 ROOMS
22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 22 + 71
22 + 25 + 25
22 + 25 + 35
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
2.20 / 3.30
2.20 / 3.23
2.20 / 2.89
2.20 / 2.57
2.20 / 2.79
2.06 / 2.63
2.50 / 3.60
2.50 / 3.17
2.50 / 3.00
2.47 / 3.18
2.29 / 2.92
3.50 / 4.00
3.46 / 4.45
3.21 / 4.09
3.00 / 3.73
4.45 / 5.65
4.23 / 5.14
3.97 / 4.67
4.80 / 5.65
4.44 / 5.18
4.85 / 5.65
2.20 / 3.30
2.20 / 3.25
2.09 / 3.06
2.08 / 2.71
2.03 / 2.54
1.86 / 2.35
2.20 / 3.21
2.20 / 2.98
Unit B
2.20 / 3.30
2.50 / 3.67
3.50 / 4.61
5.00 / 5.83
6.00 / 7.61
6.64 / 8.47
2.50 / 3.60
3.50 / 4.43
5.00 / 6.00
5.93 / 7.62
6.51 / 8.28
3.50 / 4.00
4.94 / 6.35
5.49 / 7.01
6.10 / 7.57
4.45 / 5.65
5.07 / 6.16
5.63 / 6.63
4.80 / 5.65
5.26 / 6.12
4.85 / 5.65
2.20 / 3.30
2.20 / 3.25
2.09 / 3.06
2.08 / 2.71
2.03 / 2.54
1.86 / 2.35
2.50 / 3.65
2.50 / 3.38
Unit C
2.20 / 3.30
2.50 / 3.70
3.32 / 4.87
4.73 / 6.17
5.54 / 6.92
5.99 / 7.59
2.50 / 3.65
3.50 / 4.74
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
MXZ-6C120VA1Outdoor Unit Up to 6 Indoor Units
22 + 25 + 50
22 + 25 + 60
22 + 25 + 71
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 35 + 71
22 + 50 + 50
22 + 50 + 60
22 + 50 + 71
22 + 60 + 60
22 + 60 + 71
22 + 71 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 60 + 60
25 + 60 + 71
25 + 71 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 60 + 60
35 + 60 + 71
35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 60 + 60
60 + 60 + 60
Unit A
2.02 / 2.65
1.97 / 2.49
1.83 / 2.31
2.13 / 2.75
1.97 / 2.49
1.84 / 2.31
1.72 / 2.17
1.77 / 2.25
1.68 / 2.12
1.60 / 2.00
1.61 / 2.00
1.54 / 1.90
1.48 / 1.78
2.50 / 3.60
2.41 / 3.29
2.40 / 2.95
2.20 / 2.75
2.02 / 2.58
2.34 / 3.05
2.20 / 2.75
2.04 / 2.58
1.91 / 2.42
1.98 / 2.52
1.89 / 2.37
1.80 / 2.23
1.81 / 2.24
1.73 / 2.12
1.66 / 2.01
3.20 / 4.00
2.86 / 3.62
2.69 / 3.42
2.56 / 3.20
2.64 / 3.32
2.53 / 3.14
2.42 / 2.96
2.44 / 2.98
2.34 / 2.83
2.25 / 2.69
3.53 / 4.37
3.41 / 4.16
3.27 / 3.95
3.29 / 3.94
3.83 / 4.53
Unit B
2.29 / 3.02
2.24 / 2.83
2.08 / 2.63
3.39 / 4.38
3.14 / 3.96
2.93 / 3.68
2.73 / 3.45
4.02 / 5.12
3.83 / 4.81
3.64 / 4.55
4.39 / 5.45
4.20 / 5.18
4.76 / 5.76
2.50 / 3.60
2.41 / 3.29
2.40 / 2.95
2.20 / 2.75
2.02 / 2.58
3.28 / 4.27
3.09 / 3.85
2.86 / 3.62
2.67 / 3.39
3.96 / 5.04
3.78 / 4.74
3.60 / 4.45
4.34 / 5.38
4.15 / 5.08
4.72 / 5.70
3.20 / 4.00
2.86 / 3.62
2.69 / 3.42
2.56 / 3.20
3.78 / 4.74
3.62 / 4.48
3.46 / 4.23
4.18 / 5.11
4.01 / 4.84
4.57 / 5.46
3.53 / 4.37
3.41 / 4.16
3.27 / 3.95
3.95 / 4.73
3.83 / 4.53
Unit C
4.59 / 6.03
5.38 / 6.79
5.90 / 7.46
3.39 / 4.38
4.49 / 5.65
5.03 / 6.31
5.55 / 6.99
4.02 / 5.12
4.59 / 5.77
5.16 / 6.45
4.39 / 5.45
4.97 / 6.13
4.76 / 5.76
2.50 / 3.60
3.38 / 4.61
4.80 / 5.90
5.29 / 6.60
5.75 / 7.33
3.28 / 4.27
4.41 / 5.50
4.90 / 6.20
5.42 / 6.88
3.96 / 5.04
4.53 / 5.69
5.11 / 6.32
4.34 / 5.38
4.92 / 6.01
4.72 / 5.70
3.20 / 4.00
4.08 / 5.17
4.62 / 5.86
5.19 / 6.50
3.78 / 4.74
4.34 / 5.38
4.92 / 6.01
4.18 / 5.11
4.75 / 5.73
4.57 / 5.46
3.53 / 4.37
4.09 / 4.99
4.65 / 5.61
3.95 / 4.73
3.83 / 4.53
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 43
5 ROOMS22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 35 + 71
22 + 22 + 25 + 25 + 25
22 + 22 + 25 + 25 + 35
22 + 22 + 25 + 25 + 50
22 + 22 + 25 + 25 + 60
22 + 22 + 25 + 25 + 71
22 + 22 + 25 + 35 + 35
22 + 22 + 25 + 35 + 50
22 + 22 + 25 + 35 + 60
22 + 22 + 35 + 35 + 35
22 + 22 + 35 + 35 + 50
22 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 71
22 + 25 + 25 + 35 + 35
22 + 25 + 25 + 35 + 50
22 + 25 + 25 + 35 + 60
22 + 25 + 35 + 35 + 35
22 + 25 + 35 + 35 + 50
22 + 35 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
Unit A
2.00 / 2.40
1.95 / 2.34
1.79 / 2.15
1.59 / 1.91
1.49 / 1.78
1.38 / 1.66
1.90 / 2.28
1.75 / 2.10
1.56 / 1.87
1.46 / 1.75
1.36 / 1.63
1.62 / 1.94
1.46 / 1.75
1.37 / 1.64
1.28 / 1.53
1.85 / 2.22
1.71 / 2.05
1.53 / 1.83
1.43 / 1.71
1.33 / 1.60
1.58 / 1.90
1.43 / 1.71
1.34 / 1.61
1.48 / 1.77
1.34 / 1.61
1.80 / 2.16
1.67 / 2.00
1.50 / 1.80
1.40 / 1.68
1.31 / 1.57
1.55 / 1.86
1.40 / 1.68
1.32 / 1.58
1.45 / 1.74
1.32 / 1.58
1.36 / 1.63
2.00 / 2.40
1.85 / 2.22
1.67 / 2.00
1.56 / 1.88
1.46 / 1.75
1.72 / 2.07
1.56 / 1.88
1.47 / 1.76
1.61 / 1.94
1.47 / 1.76
Unit B
2.00 / 2.40
1.95 / 2.34
1.79 / 2.15
1.59 / 1.91
1.49 / 1.78
1.38 / 1.66
1.90 / 2.28
1.75 / 2.10
1.56 / 1.87
1.46 / 1.75
1.36 / 1.63
1.62 / 1.94
1.46 / 1.75
1.37 / 1.64
1.28 / 1.53
1.85 / 2.22
1.71 / 2.05
1.53 / 1.83
1.43 / 1.71
1.33 / 1.60
1.58 / 1.90
1.43 / 1.71
1.34 / 1.61
1.48 / 1.77
1.34 / 1.61
2.05 / 2.46
1.89 / 2.27
1.70 / 2.04
1.59 / 1.91
1.49 / 1.79
1.76 / 2.11
1.59 / 1.91
1.50 / 1.80
1.64 / 1.97
1.50 / 1.80
2.16 / 2.59
2.00 / 2.40
1.85 / 2.22
1.67 / 2.00
1.56 / 1.88
1.46 / 1.75
1.72 / 2.07
1.56 / 1.88
1.47 / 1.76
1.61 / 1.94
1.47 / 1.76
Unit C
2.00 / 2.40
1.95 / 2.34
1.79 / 2.15
1.59 / 1.91
1.49 / 1.78
1.38 / 1.66
1.90 / 2.28
1.75 / 2.10
1.56 / 1.87
1.46 / 1.75
1.36 / 1.63
1.62 / 1.94
1.46 / 1.75
1.37 / 1.64
1.28 / 1.53
2.10 / 2.52
1.94 / 2.33
1.74 / 2.08
1.62 / 1.95
1.52 / 1.82
1.80 / 2.16
1.62 / 1.95
1.52 / 1.83
2.35 / 2.82
2.13 / 2.56
2.05 / 2.46
1.89 / 2.27
1.70 / 2.04
1.59 / 1.91
1.49 / 1.79
1.76 / 2.11
1.59 / 1.91
1.50 / 1.80
2.30 / 2.76
2.10 / 2.51
2.16 / 2.59
2.00 / 2.40
1.85 / 2.22
1.67 / 2.00
1.56 / 1.88
1.46 / 1.75
1.72 / 2.07
1.56 / 1.88
1.47 / 1.76
2.26 / 2.71
2.06 / 2.47
Unit D
2.00 / 2.40
1.95 / 2.34
1.79 / 2.15
1.59 / 1.91
1.49 / 1.78
1.38 / 1.66
2.16 / 2.59
1.98 / 2.38
1.77 / 2.13
1.66 / 1.99
1.54 / 1.85
2.57 / 3.09
2.32 / 2.78
2.17 / 2.61
2.03 / 2.44
2.10 / 2.52
1.94 / 2.33
1.74 / 2.08
1.62 / 1.95
1.52 / 1.82
2.52 / 3.02
2.27 / 2.73
2.13 / 2.56
2.35 / 2.82
2.13 / 2.56
2.05 / 2.46
1.89 / 2.27
1.70 / 2.04
1.59 / 1.91
1.49 / 1.79
2.46 / 2.96
2.23 / 2.68
2.10 / 2.51
2.30 / 2.76
2.10 / 2.51
2.16 / 2.59
2.00 / 2.40
1.85 / 2.22
1.67 / 2.00
1.56 / 1.88
1.46 / 1.75
2.41 / 2.90
2.19 / 2.63
2.06 / 2.47
2.26 / 2.71
2.06 / 2.47
Unit E
2.00 / 2.40
2.21 / 2.65
2.85 / 3.41
3.62 / 4.35
4.05 / 4.86
4.47 / 5.36
2.16 / 2.59
2.78 / 3.33
3.55 / 4.26
3.97 / 4.77
4.38 / 5.26
2.57 / 3.09
3.31 / 3.97
3.73 / 4.47
4.13 / 4.95
2.10 / 2.52
2.71 / 3.26
3.47 / 4.17
3.90 / 4.68
4.30 / 5.16
2.52 / 3.02
3.25 / 3.90
3.66 / 4.39
2.35 / 2.82
3.05 / 3.66
2.05 / 2.46
2.65 / 3.18
3.40 / 4.08
3.82 / 4.59
4.23 / 5.07
2.46 / 2.96
3.18 / 3.82
3.59 / 4.31
2.30 / 2.76
2.99 / 3.59
2.16 / 2.59
2.00 / 2.40
2.59 / 3.11
3.33 / 4.00
3.75 / 4.50
4.15 / 4.98
2.41 / 2.90
3.13 / 3.75
3.53 / 4.24
2.26 / 2.71
2.94 / 3.53
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 42
5 ROOMS22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 35 + 71
22 + 22 + 22 + 50 + 50
22 + 22 + 22 + 50 + 60
22 + 22 + 25 + 25 + 25
22 + 22 + 25 + 25 + 35
22 + 22 + 25 + 25 + 50
22 + 22 + 25 + 25 + 60
22 + 22 + 25 + 25 + 71
22 + 22 + 25 + 35 + 35
22 + 22 + 25 + 35 + 50
22 + 22 + 25 + 35 + 60
22 + 22 + 25 + 35 + 71
22 + 22 + 25 + 50 + 50
22 + 22 + 25 + 50 + 60
22 + 22 + 35 + 35 + 35
22 + 22 + 35 + 35 + 50
22 + 22 + 35 + 35 + 60
22 + 22 + 35 + 50 + 50
22 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 71
22 + 25 + 25 + 35 + 35
22 + 25 + 25 + 35 + 50
22 + 25 + 25 + 35 + 60
22 + 25 + 25 + 35 + 71
22 + 25 + 25 + 50 + 50
22 + 25 + 35 + 35 + 35
22 + 25 + 35 + 35 + 50
22 + 25 + 35 + 35 + 60
22 + 35 + 35 + 35 + 35
22 + 35 + 35 + 35 + 50
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
Unit A
2.20 / 2.62
2.18 / 2.57
2.11 / 2.40
1.91 / 2.14
1.78 / 1.99
1.67 / 1.85
2.16 / 2.50
2.08 / 2.34
1.87 / 2.09
1.76 / 1.95
1.64 / 1.82
1.94 / 2.17
1.76 / 1.95
1.65 / 1.83
1.56 / 1.71
1.60 / 1.78
1.53 / 1.68
2.13 / 2.46
2.03 / 2.29
1.83 / 2.05
1.73 / 1.91
1.61 / 1.79
1.90 / 2.12
1.73 / 1.91
1.62 / 1.80
1.53 / 1.68
1.59 / 1.74
1.50 / 1.65
1.77 / 1.98
1.62 / 1.80
1.54 / 1.69
1.50 / 1.65
2.11 / 2.40
1.98 / 2.23
1.80 / 2.01
1.70 / 1.88
1.60 / 1.75
1.86 / 2.08
1.70 / 1.88
1.61 / 1.77
1.51 / 1.66
1.56 / 1.71
1.75 / 1.94
1.61 / 1.77
1.52 / 1.67
1.64 / 1.82
1.52 / 1.67
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
Unit B
2.20 / 2.62
2.18 / 2.57
2.11 / 2.40
1.91 / 2.14
1.78 / 1.99
1.67 / 1.85
2.16 / 2.50
2.08 / 2.34
1.87 / 2.09
1.76 / 1.95
1.64 / 1.82
1.94 / 2.17
1.76 / 1.95
1.65 / 1.83
1.56 / 1.71
1.60 / 1.78
1.53 / 1.68
2.13 / 2.46
2.03 / 2.29
1.83 / 2.05
1.73 / 1.91
1.61 / 1.79
1.90 / 2.12
1.73 / 1.91
1.62 / 1.80
1.53 / 1.68
1.59 / 1.74
1.50 / 1.65
1.77 / 1.98
1.62 / 1.80
1.54 / 1.69
1.50 / 1.65
2.40 / 2.73
2.25 / 2.54
2.04 / 2.28
1.93 / 2.13
1.82 / 1.99
2.11 / 2.36
1.93 / 2.13
1.83 / 2.01
1.71 / 1.88
1.77 / 1.95
1.99 / 2.20
1.83 / 2.01
1.72 / 1.89
2.61 / 2.90
2.41 / 2.65
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
Unit C
2.20 / 2.62
2.18 / 2.57
2.11 / 2.40
1.91 / 2.14
1.78 / 1.99
1.67 / 1.85
2.16 / 2.50
2.08 / 2.34
1.87 / 2.09
1.76 / 1.95
1.64 / 1.82
1.94 / 2.17
1.76 / 1.95
1.65 / 1.83
1.56 / 1.71
1.60 / 1.78
1.53 / 1.68
2.42 / 2.79
2.31 / 2.60
2.08 / 2.33
1.96 / 2.18
1.83 / 2.03
2.16 / 2.41
1.96 / 2.18
1.84 / 2.04
1.74 / 1.91
1.80 / 1.98
1.70 / 1.87
2.82 / 3.15
2.58 / 2.86
2.45 / 2.70
2.39 / 2.62
2.40 / 2.73
2.25 / 2.54
2.04 / 2.28
1.93 / 2.13
1.82 / 1.99
2.11 / 2.36
1.93 / 2.13
1.83 / 2.01
1.71 / 1.88
1.77 / 1.95
2.79 / 3.09
2.56 / 2.81
2.41 / 2.65
2.61 / 2.90
2.41 / 2.65
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
Unit D
2.20 / 2.62
2.18 / 2.57
2.11 / 2.40
1.91 / 2.14
1.78 / 1.99
1.67 / 1.85
2.46 / 2.84
2.36 / 2.66
2.13 / 2.38
2.00 / 2.22
1.87 / 2.07
3.09 / 3.45
2.80 / 3.11
2.63 / 2.91
2.48 / 2.73
3.64 / 4.04
3.47 / 3.81
2.42 / 2.79
2.31 / 2.60
2.08 / 2.33
1.96 / 2.18
1.83 / 2.03
3.02 / 3.37
2.75 / 3.05
2.58 / 2.86
2.44 / 2.68
3.61 / 3.96
3.41 / 3.74
2.82 / 3.15
2.58 / 2.86
2.45 / 2.70
3.41 / 3.74
2.40 / 2.73
2.25 / 2.54
2.04 / 2.28
1.93 / 2.13
1.82 / 1.99
2.96 / 3.30
2.70 / 2.99
2.56 / 2.81
2.40 / 2.63
3.55 / 3.90
2.79 / 3.09
2.56 / 2.81
2.41 / 2.65
2.61 / 2.90
2.41 / 2.65
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.90 / 3.23
Unit E
2.20 / 2.62
2.48 / 2.92
3.36 / 3.81
4.35 / 4.86
4.86 / 5.43
5.40 / 5.98
2.46 / 2.84
3.31 / 3.72
4.26 / 4.75
4.81 / 5.32
5.30 / 5.87
3.09 / 3.45
4.01 / 4.44
4.51 / 4.99
5.04 / 5.53
3.64 / 4.04
4.16 / 4.57
2.42 / 2.79
3.23 / 3.64
4.17 / 4.65
4.71 / 5.22
5.21 / 5.77
3.02 / 3.37
3.93 / 4.35
4.43 / 4.90
4.95 / 5.44
3.61 / 3.96
4.09 / 4.49
2.82 / 3.15
3.69 / 4.09
4.21 / 4.62
3.41 / 3.74
2.40 / 2.73
3.17 / 3.55
4.08 / 4.56
4.62 / 5.12
5.16 / 5.66
2.96 / 3.30
3.85 / 4.27
4.38 / 4.81
4.87 / 5.34
3.55 / 3.90
2.79 / 3.09
3.65 / 4.01
4.14 / 4.54
2.61 / 2.90
3.45 / 3.79
2.38 / 2.68
3.12 / 3.47
4.03 / 4.47
4.54 / 5.03
5.07 / 5.56
2.90 / 3.23
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 45
4 ROOMS22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 22 + 60
22 + 22 + 22 + 71
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 25 + 60
22 + 22 + 25 + 71
22 + 22 + 35 + 35
22 + 22 + 35 + 50
22 + 22 + 35 + 60
22 + 22 + 35 + 71
22 + 22 + 50 + 50
22 + 22 + 50 + 60
22 + 22 + 50 + 71
22 + 22 + 60 + 60
22 + 22 + 60 + 71
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 25 + 60
22 + 25 + 25 + 71
22 + 25 + 35 + 35
22 + 25 + 35 + 50
22 + 25 + 35 + 60
22 + 25 + 35 + 71
22 + 25 + 50 + 50
22 + 25 + 50 + 60
22 + 25 + 50 + 71
22 + 25 + 60 + 60
22 + 25 + 60 + 71
22 + 35 + 35 + 35
22 + 35 + 35 + 50
Unit A
2.20 / 2.85
2.20 / 2.80
2.18 / 2.61
1.95 / 2.37
1.83 / 2.23
1.70 / 2.10
2.20 / 2.74
2.14 / 2.56
1.90 / 2.33
1.79 / 2.20
1.68 / 2.07
1.97 / 2.39
1.79 / 2.20
1.69 / 2.09
1.57 / 1.94
1.63 / 2.02
1.54 / 1.89
1.44 / 1.76
1.45 / 1.77
1.36 / 1.58
2.20 / 270
2.08 / 2.51
1.88 / 2.29
1.77 / 2.17
1.65 / 2.03
1.94 / 2.35
1.77 / 2.17
1.66 / 2.05
1.54 / 1.90
1.60 / 1.98
1.51 / 1.85
1.41 / 1.73
1.42 / 1.74
1.33 / 1.56
1.83 / 2.22
1.66 / 2.05
Unit B
2.20 / 2.85
2.20 / 2.80
2.18 / 2.61
1.95 / 2.37
1.83 / 2.23
1.70 / 2.10
2.20 / 2.74
2.14 / 2.56
1.90 / 2.33
1.79 / 2.20
1.68 / 2.07
1.97 / 2.39
1.79 / 2.20
1.69 / 2.09
1.57 / 1.94
1.63 / 2.02
1.54 / 1.89
1.44 / 1.76
1.45 / 1.77
1.36 / 1.58
2.50 / 3.07
2.36 / 2.85
2.13 / 2.60
2.01 / 2.46
1.87 / 2.31
2.20 / 2.67
2.01 / 2.46
1.88 / 2.32
1.75 / 2.16
1.82 / 2.24
1.72 / 2.10
1.61 / 1.96
1.62 / 1.98
1.52 / 1.77
2.89 / 3.53
2.64 / 3.25
Unit C
2.20 / 2.85
2.20 / 2.80
2.18 / 2.61
1.95 / 2.37
1.83 / 2.23
1.70 / 2.10
2.50 / 3.11
2.43 / 2.91
2.16 / 2.65
2.03 / 2.50
1.91 / 2.36
3.13 / 3.81
2.85 / 3.50
2.69 / 3.32
2.50 / 3.08
3.72 / 4.58
3.51 / 4.29
3.27 / 4.00
3.95 / 4.83
3.70 / 4.32
2.50 / 3.07
2.36 / 2.85
2.13 / 2.60
2.01 / 2.46
1.87 / 2.31
3.08 / 3.74
2.81 / 3.45
2.64 / 3.25
2.45 / 3.02
3.64 / 4.49
3.44 / 4.20
3.21 / 3.93
3.88 / 4.74
3.64 / 4.25
2.89 / 3.53
2.64 / 3.25
Unit D
2.20 / 2.85
2.50 / 3.19
3.47 / 4.17
4.44 / 5.39
5.00 / 6.10
5.49 / 6.79
2.50 / 3.11
3.40 / 4.07
4.33 / 5.29
4.88 / 6.00
5.43 / 6.69
3.13 / 3.81
4.07 / 5.00
4.62 / 5.70
5.06 / 6.25
3.72 / 4.58
4.21 / 5.14
4.65 / 5.68
3.95 / 4.83
4.38 / 5.11
2.50 / 3.07
3.30 / 3.99
4.26 / 5.20
4.82 / 5.91
5.31 / 6.55
3.08 / 3.74
4.02 / 4.92
4.52 / 5.58
4.97 / 6.13
3.64 / 4.49
4.13 / 5.04
4.56 / 5.58
3.88 / 4.74
4.31 / 5.03
2.89 / 3.53
3.77 / 4.65
Indoor unitcombination
Cooling / Heating Capacity (kW)
22 + 35 + 35 + 60
22 + 35 + 35 + 71
22 + 35 + 50 + 50
22 + 35 + 50 + 60
22 + 35 + 50 + 71
22 + 35 + 60 + 60
22 + 50 + 50 + 50
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 60 + 60
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 50 + 50
25 + 35 + 50 + 60
25 + 35 + 60 + 60
25 + 50 + 50 + 50
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50
35 + 35 + 50 + 60
Unit A
1.55 / 1.91
1.46 / 1.78
1.51 / 1.85
1.42 / 1.74
1.33 / 1.56
1.34 / 1.57
1.38 / 1.61
2.50 / 3.00
2.32 / 2.80
2.08 / 2.56
1.96 / 2.43
1.83 / 2.26
2.17 / 2.63
1.96 / 2.43
1.84 / 2.28
1.73 / 2.12
1.78 / 2.20
1.69 / 2.06
1.58 / 1.84
1.59 / 1.85
2.02 / 2.48
1.84 / 2.28
1.74 / 2.13
1.63 / 1.99
1.69 / 2.06
1.59 / 1.85
150 / 1.75
1.54 / 1.80
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.51
2.22 / 2.59
2.10 / 2.45
Unit B
2.46 / 3.04
2.32 / 2.83
2.41 / 2.94
2.26 / 2.77
2.12 / 2.48
2.14 / 2.49
3.14 / 3.66
2.50 / 3.00
2.32 / 2.80
2.08 / 2.56
1.96 / 2.43
1.83 / 2.26
2.17 / 2.63
1.96 / 2.43
1.84 / 2.28
1.73 / 2.12
1.78 / 2.20
1.69 / 2.06
1.58 / 1.84
1.59 / 1.85
2.83 / 3.47
2.58 / 3.19
2.44 / 2.98
2.28 / 2.78
2.36 / 2.89
2.22 / 2.59
2.10 / 2.45
3.09 / 3.60
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.51
2.22 / 2.59
2.10 / 2.45
Unit C
2.46 / 3.04
2.32 / 2.83
3.44 / 4.20
3.23 / 3.95
3.03 / 3.54
3.66 / 4.27
3.14 / 3.66
2.50 / 3.00
2.32 / 2.80
2.08 / 2.56
1.96 / 2.43
1.83 / 2.26
3.03 / 3.68
2.75 / 3.40
2.58 / 3.19
2.42 / 2.96
3.57 / 4.40
3.38 / 4.13
3.16 / 3.68
3.81 / 4.45
2.83 / 3.47
2.58 / 3.19
2.44 / 2.98
2.28 / 2.78
3.38 / 4.13
3.18 / 3.71
3.60 / 4.20
3.09 / 3.60
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.51
3.18 / 3.71
3.00 / 3.50
Unit D
4.22 / 5.21
4.70 / 5.75
3.44 / 4.20
3.88 / 4.74
4.31 / 5.03
3.66 / 4.27
3.14 / 3.66
2.50 / 3.00
3.25 / 3.91
4.16 / 5.12
4.71 / 5.82
5.20 / 6.42
3.03 / 3.68
3.93 / 4.85
4.43 / 5.46
4.92 / 6.01
3.57 / 4.40
4.05 / 4.95
4.48 / 5.23
3.81 / 4.45
2.83 / 3.47
3.69 / 4.55
4.18 / 5.11
4.62 / 5.65
3.38 / 4.13
3.81 / 4.45
3.60 / 4.20
3.09 / 3.60
2.68 / 3.30
3.48 / 4.26
3.93 / 4.80
4.36 / 5.08
3.18 / 3.71
3.60 / 4.20
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 44
1 ROOM22
25
35
50
60
71
100
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
22 + 71
22 + 100
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
25 + 100
35 + 35
35 + 50
35 + 60
35 + 71
35 + 100
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
60 + 100
71 + 71
71 + 100
3 ROOMS22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 22 + 71
22 + 22 + 100
22 + 25 + 25
22 + 25 + 35
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
10.00 / 11.20
2.20 / 2.50
2.20 / 2.53
2.20 / 2.51
2.20 / 2.51
2.20 / 2.52
2.20 / 2.51
2.20 / 2.51
2.50 / 2.85
2.50 / 2.88
2.50 / 2.87
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
3.50 / 4.00
3.50 / 3.99
3.50 / 4.02
3.50 / 4.00
3.50 / 3.99
5.00 / 5.70
5.00 / 5.73
5.00 / 5.70
6.00 / 6.85
6.00 / 6.87
5.25 / 6.00
7.00 / 8.00
5.81 / 6.64
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.14 / 2.44
2.20 / 2.51
2.20 / 2.52
Unit B
2.20 / 2.50
2.50 / 2.87
3.50 / 3.99
5.00 / 5.69
6.00 / 6.88
7.10 / 8.09
10.00 / 11.39
2.50 / 2.85
3.50 / 4.03
5.00 / 5.73
6.00 / 6.85
7.10 / 8.14
10.00 / 11.44
3.50 / 4.00
5.00 / 5.71
6.00 / 6.88
7.10 / 8.10
10.00 / 11.41
5.00 / 5.70
6.00 / 6.87
7.10 / 8.10
6.00 / 6.85
7.10 / 8.13
8.75 / 10.00
7.00 / 8.00
8.19 / 9.36
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.14 / 2.44
2.50 / 2.85
2.50 / 2.87
Unit C
2.20 / 2.50
2.50 / 2.86
3.50 / 3.99
5.00 / 5.69
6.00 / 6.87
7.10 / 8.09
9.72 / 11.11
2.50 / 2.85
3.50 / 4.01
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
MXZ-8B140VA1Outdoor Unit Up to 8 Indoor Units
22 + 25 + 50
22 + 25 + 60
22 + 25 + 71
22 + 25 + 100
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 35 + 71
22 + 35 + 100
22 + 50 + 50
22 + 50 + 60
22 + 50 + 71
22 + 50 + 100
22 + 60 + 60
22 + 60 + 71
22 + 60 + 100
22 + 71 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 25 + 100
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 35 + 100
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 50 + 100
25 + 60 + 60
25 + 60 + 71
25 + 60 + 100
25 + 71 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 35 + 100
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 50 + 100
35 + 60 + 60
35 + 60 + 71
35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 60 + 60
50 + 60 + 71
60 + 60 + 60
Unit A
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
2.10 / 2.39
2.20 / 2.51
2.20 / 2.51
2.20 / 2.52
2.20 / 2.51
1.96 / 2.24
2.20 / 2.51
2.20 / 2.52
2.15 / 2.46
1.79 / 2.05
2.17 / 2.48
2.01 / 2.30
1.69 / 1.93
1.88 / 2.15
2.50 / 2.87
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.50 / 2.87
2.50 / 2.86
2.50 / 2.85
2.50 / 2.86
2.19 / 2.50
2.50 / 2.86
2.50 / 2.85
2.40 / 2.74
2.00 / 2.29
2.41 / 2.76
2.24 / 2.56
1.89 / 2.16
2.10 / 2.40
3.50 / 4.00
3.50 / 4.00
3.50 / 4.01
3.48 / 3.97
2.88 / 3.29
3.50 / 3.99
3.38 / 3.86
3.14 / 3.59
2.65 / 3.03
3.16 / 3.61
2.95 / 3.37
2.77 / 3.16
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.12 / 4.71
3.87 / 4.42
4.67 / 5.33
Unit B
2.50 / 2.86
2.50 / 2.85
2.50 / 2.86
2.38 / 2.72
3.50 / 3.99
3.50 / 3.99
3.50 / 4.01
3.50 / 3.99
3.12 / 3.57
5.00 / 5.70
5.00 / 5.72
4.90 / 5.59
4.07 / 4.65
5.92 / 6.76
5.49 / 6.27
4.62 / 5.27
6.06 / 6.93
2.50 / 2.87
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
3.50 / 4.02
3.50 / 4.01
3.50 / 4.00
3.50 / 4.01
3.06 / 3.50
5.00 / 5.72
5.00 / 5.70
4.79 / 5.48
4.00 / 4.57
5.79 / 6.62
5.38 / 6.15
4.54 / 5.19
5.95 / 6.80
3.50 / 4.00
3.50 / 4.00
3.50 / 4.01
3.48 / 3.97
2.88 / 3.29
5.00 / 5.70
4.83 / 5.52
4.49 / 5.13
3.78 / 4.32
5.42 / 6.19
5.06 / 5.78
5.62 / 6.42
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.94 / 5.65
4.64 / 5.30
4.67 / 5.33
Unit C
5.00 / 5.72
6.00 / 6.84
7.10 / 8.12
9.52 / 10.88
3.50 / 3.99
5.00 / 5.70
6.00 / 6.87
7.10 / 8.10
8.92 / 10.19
5.00 / 5.70
6.00 / 6.86
6.95 / 7.94
8.14 / 9.30
5.92 / 6.76
6.50 / 7.42
7.69 / 8.79
6.06 / 6.93
2.50 / 2.87
3.50 / 3.99
5.00 / 5.70
6.00 / 6.87
7.10 / 8.10
9.33 / 10.67
3.50 / 4.02
5.00 / 5.73
6.00 / 6.85
7.10 / 8.13
8.75 / 10.00
5.00 / 5.72
6.00 / 6.84
6.81 / 7.78
8.00 / 9.14
5.79 / 6.62
6.37 / 7.28
7.57 / 8.65
5.95 / 6.80
3.50 / 4.00
5.00 / 5.71
6.00 / 6.88
7.05 / 8.06
8.24 / 9.41
5.00 / 5.70
5.79 / 6.62
6.37 / 7.28
7.57 / 8.65
5.42 / 6.19
5.99 / 6.84
5.62 / 6.42
4.67 / 5.33
5.25 / 6.00
5.81 / 6.64
4.94 / 5.65
5.49 / 6.28
4.67 / 5.33
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 47
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 50 + 50
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 35
6 ROOMS22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 35
22 + 22 + 22 + 25 + 25 + 50
22 + 22 + 22 + 25 + 25 + 60
22 + 22 + 22 + 25 + 35 + 35
22 + 22 + 22 + 25 + 35 + 50
22 + 22 + 22 + 35 + 35 + 35
22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 50
22 + 22 + 25 + 25 + 25 + 60
22 + 22 + 25 + 25 + 35 + 35
22 + 22 + 25 + 25 + 35 + 50
22 + 22 + 25 + 35 + 35 + 35
22 + 25 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 35 + 35
22 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 35 + 35
Unit A
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
1.95 / 2.16
1.79 / 1.97
1.69 / 1.86
1.83 / 2.03
1.69 / 1.86
2.44 / 2.68
2.00 / 2.33
1.96 / 2.28
1.82 / 2.12
1.65 / 1.93
1.55 / 1.81
1.91 / 2.23
1.78 / 2.08
1.62 / 1.89
1.53 / 1.78
1.67 / 1.95
1.53 / 1.78
1.87 / 2.18
1.75 / 2.04
1.59 / 1.86
1.50 / 1.75
1.64 / 1.91
1.50 / 1.75
1.54 / 1.80
1.83 / 2.14
1.71 / 2.00
1.56 / 1.82
1.47 / 1.72
1.61 / 1.88
1.47 / 1.72
1.52 / 1.77
1.80 / 2.10
1.68 / 1.96
1.53 / 1.79
1.58 / 1.84
1.49 / 1.74
2.00 / 2.33
1.88 / 2.19
1.71 / 2.00
1.76 / 2.06
1.67 / 1.94
Unit B
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
1.95 / 2.16
1.79 / 1.97
1.69 / 1.86
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68
2.00 / 2.33
1.96 / 2.28
1.82 / 2.12
1.65 / 1.93
1.55 / 1.81
1.91 / 2.23
1.78 / 2.08
1.62 / 1.89
1.53 / 1.78
1.67 / 1.95
1.53 / 1.78
1.87 / 2.18
1.75 / 2.04
1.59 / 1.86
1.50 / 1.75
1.64 / 1.91
1.50 / 1.75
1.54 / 1.80
1.83 / 2.14
1.71 / 2.00
1.56 / 1.82
1.47 / 1.72
1.61 / 1.88
1.47 / 1.72
1.52 / 1.77
2.04 / 2.38
1.91 / 2.23
1.74 / 2.03
1.80 / 2.10
1.69 / 1.98
2.00 / 2.33
1.88 / 2.19
1.71 / 2.00
1.76 / 2.06
1.67 / 1.94
Unit C
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
2.73 / 3.03
2.51 / 2.76
2.37 / 2.61
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68
2.00 / 2.33
1.96 / 2.28
1.82 / 2.12
1.65 / 1.93
1.55 / 1.81
1.91 / 2.23
1.78 / 2.08
1.62 / 1.89
1.53 / 1.78
1.67 / 1.95
1.53 / 1.78
1.87 / 2.18
1.75 / 2.04
1.59 / 1.86
1.50 / 1.75
1.64 / 1.91
1.50 / 1.75
1.54 / 1.80
2.08 / 2.43
1.95 / 2.27
1.78 / 2.07
1.68 / 1.96
1.83 / 2.13
1.68 / 1.96
1.72 / 2.01
2.04 / 2.38
1.91 / 2.23
1.74 / 2.03
1.80 / 2.10
1.69 / 1.98
2.00 / 2.33
1.88 / 2.19
1.71 / 2.00
1.76 / 2.06
1.67 / 1.94
Unit D
2.65 / 2.93
2.51 / 2.76
3.49 / 3.83
2.73 / 3.03
2.51 / 2.76
2.37 / 2.61
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68
2.00 / 2.33
1.96 / 2.28
1.82 / 2.12
1.65 / 1.93
1.55 / 1.81
1.91 / 2.23
1.78 / 2.08
1.62 / 1.89
1.53 / 1.78
1.67 / 1.95
1.53 / 1.78
2.13 / 2.48
1.99 / 2.32
1.81 / 2.11
1.70 / 1.99
1.86 / 2.17
1.70 / 1.99
2.46 / 2.87
2.08 / 2.43
1.95 / 2.27
1.78 / 2.07
1.68 / 1.96
1.83 / 2.13
1.68 / 1.96
2.41 / 2.82
2.04 / 2.38
1.91 / 2.23
1.74 / 2.03
1.80 / 2.10
2.37 / 2.77
2.00 / 2.33
1.88 / 2.19
1.71 / 2.00
1.76 / 2.06
2.33 / 2.72
Unit E
3.78 / 4.19
4.31 / 4.73
3.49 / 3.83
2.73 / 3.03
3.59 / 3.94
4.07 / 4.47
2.57 / 2.84
3.39 / 3.72
2.44 / 2.68
2.00 / 2.33
1.96 / 2.28
1.82 / 2.12
1.65 / 1.93
1.55 / 1.81
2.17 / 2.54
2.03 / 2.36
1.84 / 2.15
1.73 / 2.02
2.66 / 3.10
2.43 / 2.83
2.13 / 2.48
1.99 / 2.32
1.81 / 2.11
1.70 / 1.99
2.61 / 3.04
2.39 / 2.78
2.46 / 2.87
2.08 / 2.43
1.95 / 2.27
1.78 / 2.07
1.68 / 1.96
2.56 / 2.99
2.35 / 2.74
2.41 / 2.82
2.04 / 2.38
1.91 / 2.23
1.74 / 2.03
2.51 / 2.93
2.37 / 2.77
2.00 / 2.33
1.88 / 2.19
1.71 / 2.00
2.47 / 2.88
2.33 / 2.72
Unit F
2.00 / 2.33
2.22 / 2.59
2.90 / 3.38
3.75 / 4.38
4.24 / 4.94
2.17 / 2.54
2.84 / 3.31
3.68 / 4.29
4.16 / 4.86
2.66 / 3.10
3.47 / 4.05
2.13 / 2.48
2.78 / 3.25
3.61 / 4.22
4.09 / 4.77
2.61 / 3.04
3.41 / 3.98
2.46 / 2.87
2.08 / 2.43
2.73 / 3.18
3.55 / 4.14
4.02 / 4.69
2.56 / 2.99
3.35 / 3.91
2.41 / 2.82
2.04 / 2.38
2.68 / 3.12
3.49 / 4.07
2.51 / 2.93
2.37 / 2.77
2.00 / 2.33
2.63 / 3.06
3.43 / 4.00
2.47 / 2.88
2.33 / 2.72
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 46
5 ROOMS22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 35 + 71
22 + 22 + 22 + 50 + 50
22 + 22 + 22 + 50 + 60
22 + 22 + 25 + 25 + 25
22 + 22 + 25 + 25 + 35
22 + 22 + 25 + 25 + 50
22 + 22 + 25 + 25 + 60
22 + 22 + 25 + 25 + 71
22 + 22 + 25 + 35 + 35
22 + 22 + 25 + 35 + 50
22 + 22 + 25 + 35 + 60
22 + 22 + 25 + 35 + 71
22 + 22 + 25 + 50 + 50
22 + 22 + 25 + 50 + 60
22 + 22 + 35 + 35 + 35
22 + 22 + 35 + 35 + 50
22 + 22 + 35 + 35 + 60
22 + 22 + 35 + 35 + 71
22 + 22 + 35 + 50 + 50
22 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 71
22 + 25 + 25 + 35 + 35
22 + 25 + 25 + 35 + 50
22 + 25 + 25 + 35 + 60
22 + 25 + 25 + 35 + 71
22 + 25 + 25 + 50 + 50
22 + 25 + 25 + 50 + 60
22 + 25 + 35 + 35 + 35
22 + 25 + 35 + 35 + 50
22 + 25 + 35 + 35 + 60
22 + 25 + 35 + 50 + 50
22 + 35 + 35 + 35 + 35
22 + 35 + 35 + 35 + 50
Unit A
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
2.20 / 2.52
2.08 / 2.38
1.94 / 2.21
2.20 / 2.52
2.20 / 2.51
2.18 / 2.50
2.04 / 2.33
1.90 / 2.17
2.20 / 2.51
2.04 / 2.33
1.91 / 2.19
1.79 / 2.05
1.86 / 2.12
1.75 / 2.00
2.20 / 2.51
2.20 / 2.51
2.14 / 2.44
2.00 / 2.29
1.87 / 2.13
2.20 / 2.52
2.00 / 2.29
1.88 / 2.15
1.76 / 2.01
1.82 / 2.08
1.72 / 1.97
2.07 / 2.36
1.88 / 2.15
1.77 / 2.02
1.66 / 1.90
1.72 / 1.97
2.20 / 2.51
2.20 / 2.52
2.10 / 2.39
1.96 / 2.24
1.83 / 2.10
2.17 / 2.48
1.96 / 2.24
1.84 / 2.11
1.73 / 1.98
1.79 / 2.05
1.69 / 1.93
2.03 / 2.32
1.84 / 2.11
1.74 / 1.99
1.69 / 1.93
1.90 / 2.17
1.74 / 1.99
Unit B
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
2.20 / 2.52
2.08 / 2.38
1.94 / 2.21
2.20 / 2.52
2.20 / 2.51
2.18 / 2.50
2.04 / 2.33
1.90 / 2.17
2.20 / 2.51
2.04 / 2.33
1.91 / 2.19
1.79 / 2.05
1.86 / 2.12
1.75 / 2.00
2.20 / 2.51
2.20 / 2.51
2.14 / 2.44
2.00 / 2.29
1.87 / 2.13
2.20 / 2.52
2.00 / 2.29
1.88 / 2.15
1.76 / 2.01
1.82 / 2.08
1.72 / 1.97
2.07 / 2.36
1.88 / 2.15
1.77 / 2.02
1.66 / 1.90
1.72 / 1.97
2.50 / 2.85
2.50 / 2.86
2.38 / 2.72
2.23 / 2.55
2.08 / 2.38
2.46 / 2.82
2.23 / 2.55
2.10 / 2.40
1.97 / 2.25
2.03 / 2.33
1.92 / 2.20
2.30 / 2.63
2.10 / 2.40
1.98 / 2.26
1.92 / 2.20
3.02 / 3.46
2.77 / 3.16
Unit C
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
2.20 / 2.52
2.08 / 2.38
1.94 / 2.21
2.20 / 2.52
2.20 / 2.51
2.18 / 2.50
2.04 / 2.33
1.90 / 2.17
2.20 / 2.51
2.04 / 2.33
1.91 / 2.19
1.79 / 2.05
1.86 / 2.12
1.75 / 2.00
2.50 / 2.86
2.50 / 2.85
2.43 / 2.78
2.27 / 2.60
2.12 / 2.42
2.50 / 2.86
2.27 / 2.60
2.13 / 2.44
2.00 / 2.29
2.07 / 2.37
1.96 / 2.23
3.29 / 3.76
2.99 / 3.41
2.82 / 3.22
2.65 / 3.03
2.74 / 3.13
2.50 / 2.85
2.50 / 2.86
2.38 / 2.72
2.23 / 2.55
2.08 / 2.38
2.46 / 2.82
2.23 / 2.55
2.10 / 2.40
1.97 / 2.25
2.03 / 2.33
1.92 / 2.20
3.22 / 3.68
2.93 / 3.35
2.77 / 3.16
2.69 / 3.08
3.02 / 3.46
2.77 / 3.16
Unit D
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
2.20 / 2.52
2.08 / 2.38
1.94 / 2.21
2.50 / 2.87
2.50 / 2.86
2.48 / 2.84
2.32 / 2.65
2.16 / 2.47
3.50 / 3.99
3.25 / 3.71
3.04 / 3.48
2.85 / 3.26
4.22 / 4.82
3.98 / 4.55
2.50 / 2.86
2.50 / 2.85
2.43 / 2.78
2.27 / 2.60
2.12 / 2.42
3.50 / 4.00
3.18 / 3.64
2.99 / 3.41
2.80 / 3.20
4.14 / 4.73
3.91 / 4.47
3.29 / 3.76
2.99 / 3.41
2.82 / 3.22
2.65 / 3.03
3.91 / 4.47
2.50 / 2.85
2.50 / 2.86
2.38 / 2.72
2.23 / 2.55
2.08 / 2.38
3.45 / 3.94
3.12 / 3.57
2.93 / 3.35
2.75 / 3.15
4.07 / 4.65
3.85 / 4.40
3.22 / 3.68
2.93 / 3.35
2.77 / 3.16
3.85 / 4.40
3.02 / 3.46
2.77 / 3.16
Unit E
2.20 / 2.52
2.50 / 2.85
3.50 / 4.01
5.00 / 5.72
5.68 / 6.49
6.25 / 7.14
2.50 / 2.87
3.50 / 4.00
4.96 / 5.67
5.56 / 6.36
6.14 / 7.01
3.50 / 3.99
4.64 / 5.30
5.22 / 5.96
5.78 / 6.60
4.22 / 4.82
4.77 / 5.45
2.50 / 2.86
3.50 / 3.99
4.86 / 5.56
5.45 / 6.23
6.02 / 6.88
3.50 / 4.00
4.55 / 5.19
5.12 / 5.85
5.68 / 6.49
4.14 / 4.73
4.69 / 5.36
3.29 / 3.76
4.27 / 4.88
4.83 / 5.52
5.37 / 6.14
3.91 / 4.47
2.50 / 2.85
3.50 / 4.00
4.76 / 5.44
5.35 / 6.11
5.92 / 6.76
3.45 / 3.94
4.46 / 5.10
5.03 / 5.75
5.58 / 6.38
4.07 / 4.65
4.62 / 5.27
3.22 / 3.68
4.19 / 4.79
4.75 / 5.42
3.85 / 4.40
3.02 / 3.46
3.95 / 4.52
Unit F Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 49
4 ROOMS
22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 22 + 60
22 + 22 + 22 + 71
22 + 22 + 22 + 100
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 25 + 60
22 + 22 + 25 + 71
22 + 22 + 25 + 100
22 + 22 + 35 + 35
22 + 22 + 35 + 50
22 + 22 + 35 + 60
22 + 22 + 35 + 71
22 + 22 + 35 + 100
22 + 22 + 50 + 50
22 + 22 + 50 + 60
22 + 22 + 50 + 71
22 + 22 + 60 + 60
22 + 22 + 60 + 71
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 25 + 60
22 + 25 + 25 + 71
22 + 25 + 25 + 100
22 + 25 + 35 + 35
22 + 25 + 35 + 50
22 + 25 + 35 + 60
22 + 25 + 35 + 71
22 + 25 + 35 + 100
22 + 25 + 50 + 50
22 + 25 + 50 + 60
22 + 25 + 50 + 71
22 + 25 + 60 + 60
22 + 25 + 60 + 71
22 + 35 + 35 + 35
22 + 35 + 35 + 50
Unit A
2.20 / 2.53
2.20 / 2.51
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
1.86 / 2.12
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
1.82 / 2.08
2.20 / 2.51
2.20 / 2.51
2.20 / 2.52
2.05 / 2.35
1.72 / 1.97
2.14 / 2.44
2.00 / 2.29
1.87 / 2.13
1.88 / 2.15
1.76 / 2.01
2.20 / 2.52
2.20 / 2.51
2.20 / 2.51
2.20 / 2.52
2.15 / 2.46
1.79 / 2.05
2.20 / 2.52
2.20 / 2.52
2.17 / 2.48
2.01 / 2.30
1.69 / 1.93
2.10 / 2.39
1.96 / 2.24
1.83 / 2.10
1.84 / 2.10
1.73 / 1.98
2.20 / 2.51
2.17 / 2.48
Unit B
2.20 / 2.53
2.20 / 2.51
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
1.86 / 2.12
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
1.82 / 2.08
2.20 / 2.51
2.20 / 2.51
2.20 / 2.52
2.05 / 2.35
1.72 / 1.97
2.14 / 2.44
2.00 / 2.29
1.87 / 2.13
1.88 / 2.15
1.76 / 2.01
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.45 / 2.80
2.03 / 2.33
2.50 / 2.86
2.50 / 2.86
2.46 / 2.82
2.29 / 2.61
1.92 / 2.20
2.38 / 2.72
2.23 / 2.55
2.08 / 2.38
2.10 / 2.40
1.97 / 2.25
3.50 / 4.00
3.45 / 3.94
Unit C
2.20 / 2.53
2.20 / 2.51
2.20 / 2.50
2.20 / 2.52
2.20 / 2.51
2.20 / 2.52
1.86 / 2.12
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.50 / 2.86
2.07 / 2.37
3.50 / 3.99
3.50 / 3.99
3.50 / 4.00
3.27 / 3.73
2.74 / 3.13
4.86 / 5.56
4.55 / 5.19
4.24 / 4.85
5.12 / 5.85
4.80 / 5.49
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.45 / 2.80
2.03 / 2.33
3.50 / 4.01
3.50 / 4.00
3.45 / 3.94
3.20 / 3.66
2.69 / 3.08
4.76 / 5.44
4.46 / 5.10
4.17 / 4.76
5.03 / 5.75
4.72 / 5.39
3.50 / 4.00
3.45 / 3.94
Unit D
2.20 / 2.53
2.50 / 2.86
3.50 / 3.99
5.00 / 5.73
6.00 / 6.86
7.10 / 8.14
8.43 / 9.64
2.50 / 2.85
3.50 / 4.00
5.00 / 5.71
6.00 / 6.84
7.10 / 8.11
8.28 / 9.47
3.50 / 3.99
5.00 / 5.70
6.00 / 6.86
6.63 / 7.57
7.82 / 8.94
4.86 / 5.56
5.45 / 6.23
6.02 / 6.88
5.12 / 5.85
5.68 / 6.49
2.50 / 2.86
3.50 / 3.99
5.00 / 5.70
6.00 / 6.86
6.95 / 7.94
8.14 / 9.30
3.50 / 4.01
5.00 / 5.72
5.92 / 6.76
6.50 / 7.42
7.69 / 8.79
4.76 / 5.44
5.35 / 6.11
5.92 / 6.76
5.03 / 5.75
5.58 / 6.38
3.50 / 4.00
4.93 / 5.63
Indoor unitcombination
Cooling / Heating Capacity (kW)
22 + 35 + 35 + 60
22 + 35 + 35 + 71
22 + 35 + 50 + 50
22 + 35 + 50 + 60
22 + 35 + 50 + 71
22 + 35 + 60 + 60
22 + 50 + 50 + 50
22 + 50 + 50 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 25 + 100
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 35 + 100
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 60 + 60
25 + 25 + 60 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 50 + 50
25 + 35 + 50 + 60
25 + 35 + 50 + 71
25 + 35 + 60 + 60
25 + 50 + 50 + 50
25 + 50 + 50 + 60
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50
35 + 35 + 50 + 60
35 + 50 + 50 + 50
Unit A
2.03 / 2.32
1.89 / 2.16
1.96 / 2.24
1.84 / 2.11
1.73 / 1.98
1.74 / 1.99
1.79 / 2.05
1.69 / 1.93
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.40 / 2.74
2.00 / 2.29
2.50 / 2.85
2.50 / 2.85
2.41 / 2.76
2.24 / 2.56
1.89 / 2.16
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.06 / 2.35
1.93 / 2.21
2.50 / 2.87
2.41 / 2.76
2.26 / 2.58
2.11 / 2.41
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
1.94 / 2.22
2.00 / 2.29
1.89 / 2.16
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
2.88 / 3.29
2.72 / 3.11
2.65 / 3.03
Unit B
3.22 / 3.68
3.01 / 3.44
3.12 / 3.57
2.93 / 3.35
2.75 / 3.15
2.77 / 3.16
4.07 / 4.65
3.85 / 4.40
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.40 / 2.74
2.00 / 2.29
2.50 / 2.85
2.50 / 2.85
2.41 / 2.76
2.24 / 2.56
1.89 / 2.16
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.06 / 2.35
1.93 / 2.21
3.50 / 4.01
3.38 / 3.86
3.16 / 3.61
2.95 / 3.37
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
2.72 / 3.11
4.00 / 4.57
3.78 / 4.32
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
2.88 / 3.29
2.72 / 3.11
3.78 / 4.32
Unit C
3.22 / 3.68
3.01 / 3.44
4.46 / 5.10
4.19 / 4.79
3.93 / 4.49
4.75 / 5.42
4.07 / 4.65
3.85 / 4.40
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.40 / 2.74
2.00 / 2.29
3.50 / 4.00
3.50 / 3.99
3.38 / 3.86
3.14 / 3.59
2.65 / 3.03
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.94 / 5.65
4.64 / 5.30
3.50 / 4.01
3.38 / 3.86
3.16 / 3.61
2.95 / 3.37
4.38 / 5.00
4.12 / 4.71
3.87 / 4.42
4.67 / 5.33
4.00 / 4.57
3.78 / 4.32
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
4.12 / 4.71
3.89 / 4.44
3.78 / 4.32
Unit D
5.53 / 6.32
6.10 / 6.97
4.46 / 5.10
5.03 / 5.75
5.58 / 6.38
4.75 / 5.42
4.07 / 4.65
4.62 / 5.27
2.50 / 2.85
3.50 / 4.01
5.00 / 5.72
6.00 / 6.84
6.81 / 7.78
8.00 / 9.14
3.50 / 4.00
5.00 / 5.70
5.79 / 6.62
6.37 / 7.28
7.57 / 8.65
4.67 / 5.33
5.25 / 6.00
5.81 / 6.64
4.94 / 5.65
5.49 / 6.28
3.50 / 4.01
4.83 / 5.52
5.42 / 6.19
5.99 / 6.84
4.38 / 5.00
4.94 / 5.65
5.49 / 6.28
4.67 / 5.33
4.00 / 4.57
4.54 / 5.19
3.50 / 4.00
4.52 / 5.16
5.09 / 5.82
5.65 / 6.45
4.12 / 4.71
4.67 / 5.33
3.78 / 4.32
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 48
22 + 25 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 35 + 35
22 + 25 + 25 + 25 + 35 + 50
22 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 35 + 35
7 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 22 + 25 + 25 + 35
22 + 22 + 22 + 22 + 25 + 35 + 35
22 + 22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 25 + 25
22 + 22 + 25 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 35
8 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 22 + 25 + 25 + 25
Unit A
1.96 / 2.24
1.79 / 2.05
1.69 / 1.93
1.84 / 2.11
1.69 / 1.93
1.74 / 1.99
2.33 / 2.67
2.19 / 2.50
2.00 / 2.29
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
1.93 / 2.20
1.81 / 2.07
1.66 / 1.90
1.71 / 1.96
1.89 / 2.16
1.78 / 2.03
1.68 / 1.92
1.86 / 2.12
1.75 / 2.00
1.82 / 2.08
1.72 / 1.97
1.79 / 2.05
1.69 / 1.93
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.66 / 1.90
Unit B
2.23 / 2.55
2.03 / 2.33
1.92 / 2.20
2.10 / 2.40
1.92 / 2.20
1.98 / 2.26
2.33 / 2.67
2.19 / 2.50
2.00 / 2.29
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
1.93 / 2.20
1.81 / 2.07
1.66 / 1.90
1.71 / 1.96
1.89 / 2.16
1.78 / 2.03
1.68 / 1.92
1.86 / 2.12
1.75 / 2.00
1.82 / 2.08
1.72 / 1.97
2.03 / 2.33
1.92 / 2.20
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.66 / 1.90
Unit C
2.23 / 2.55
2.03 / 2.33
1.92 / 2.20
2.10 / 2.40
1.92 / 2.20
1.98 / 2.26
2.33 / 2.67
2.19 / 2.50
2.00 / 2.29
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
1.93 / 2.20
1.81 / 2.07
1.66 / 1.90
1.71 / 1.96
1.89 / 2.16
1.78 / 2.03
1.68 / 1.92
1.86 / 2.12
1.75 / 2.00
2.07 / 2.37
1.96 / 2.23
2.03 / 2.33
1.92 / 2.20
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.66 / 1.90
Unit D
2.23 / 2.55
2.03 / 2.33
1.92 / 2.20
2.10 / 2.40
1.92 / 2.20
2.77 / 3.16
2.33 / 2.67
2.19 / 2.50
2.00 / 2.29
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
2.72 / 3.11
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
1.93 / 2.20
1.81 / 2.07
1.66 / 1.90
1.71 / 1.96
1.89 / 2.16
1.78 / 2.03
1.68 / 1.92
2.11 / 2.41
1.99 / 2.27
2.07 / 2.37
1.96 / 2.23
2.03 / 2.33
1.92 / 2.20
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.66 / 1.90
Unit E
2.23 / 2.55
2.03 / 2.33
1.92 / 2.20
2.93 / 3.35
2.69 / 3.08
2.77 / 3.16
2.33 / 2.67
2.19 / 2.50
2.00 / 2.29
1.89 / 2.16
2.88 / 3.29
2.65 / 3.03
2.72 / 3.11
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
1.93 / 2.20
1.81 / 2.07
1.66 / 1.90
1.71 / 1.96
2.15 / 2.45
2.02 / 2.31
1.91 / 2.19
2.11 / 2.41
1.99 / 2.27
2.07 / 2.37
1.96 / 2.23
2.03 / 2.33
1.92 / 2.20
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.66 / 1.90
Unit F
3.12 / 3.57
4.07 / 4.65
4.62 / 5.27
2.93 / 3.35
3.85 / 4.40
2.77 / 3.16
2.33 / 2.67
3.06 / 3.50
4.00 / 4.57
4.54 / 5.19
2.88 / 3.29
3.78 / 4.32
2.72 / 3.11
2.00 / 2.29
1.96 / 2.24
1.84 / 2.11
1.69 / 1.93
2.19 / 2.50
2.06 / 2.35
1.89 / 2.16
2.72 / 3.11
2.15 / 2.45
2.02 / 2.31
2.68 / 3.06
2.11 / 2.41
1.99 / 2.27
2.07 / 2.37
1.96 / 2.23
2.03 / 2.33
1.92 / 2.20
2.00 / 2.29
1.89 / 2.16
1.75 / 2.00
1.72 / 1.97
1.69 / 1.93
1.89 / 2.16
Unit G
2.00 / 2.29
2.23 / 2.55
2.93 / 3.35
3.85 / 4.40
2.19 / 2.50
2.88 / 3.29
3.78 / 4.32
2.72 / 3.11
2.15 / 2.45
2.83 / 3.24
2.68 / 3.06
2.11 / 2.41
2.78 / 3.18
2.07 / 2.37
2.74 / 3.13
2.03 / 2.33
2.69 / 3.08
2.00 / 2.29
2.65 / 3.03
1.75 / 2.00
1.72 / 1.97
1.92 / 2.20
1.89 / 2.16
Unit H
1.75 / 2.00
1.96 / 2.23
1.92 / 2.20
1.89 / 2.16
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 51
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 35 + 71
25 + 25 + 25 + 50 + 50
25 + 25 + 25 + 50 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 25 + 35 + 50 + 50
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 35
6 ROOMS22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 35
22 + 22 + 22 + 25 + 25 + 50
22 + 22 + 22 + 25 + 25 + 60
22 + 22 + 22 + 25 + 35 + 35
22 + 22 + 22 + 25 + 35 + 50
22 + 22 + 22 + 35 + 35 + 35
22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 50
22 + 22 + 25 + 25 + 25 + 60
22 + 22 + 25 + 25 + 35 + 35
22 + 22 + 25 + 25 + 35 + 50
22 + 22 + 25 + 35 + 35 + 35
22 + 22 + 35 + 35 + 35 + 35
22 + 25 + 25 + 25 + 25 + 25
Unit A
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
1.89 / 2.16
2.12 / 2.42
1.94 / 2.22
2.80 / 3.20
2.20 / 2.52
2.20 / 2.51
2.12 / 2.43
1.93 / 2.20
1.81 / 2.07
1.70 / 1.94
2.20 / 2.52
2.08 / 2.38
1.89 / 2.16
1.78 / 2.03
1.67 / 1.91
1.95 / 2.23
1.78 / 2.03
1.68 / 1.92
2.18 / 2.50
2.04 / 2.33
1.86 / 2.12
1.75 / 2.00
1.91 / 2.19
1.75 / 2.00
1.80 / 2.06
2.14 / 2.44
2.00 / 2.29
1.82 / 2.08
1.72 / 1.97
1.88 / 2.15
1.72 / 1.97
1.70 / 2.02
1.67 / 1.91
2.10 / 2.39
Unit B
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
1.89 / 2.16
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20
2.20 / 2.52
2.20 / 2.51
2.12 / 2.43
1.93 / 2.20
1.81 / 2.07
1.70 / 1.94
2.20 / 2.52
2.08 / 2.38
1.89 / 2.16
1.78 / 2.03
1.67 / 1.91
1.95 / 2.23
1.78 / 2.03
1.68 / 1.92
2.18 / 2.50
2.04 / 2.33
1.86 / 2.12
1.75 / 2.00
1.91 / 2.19
1.75 / 2.00
1.80 / 2.06
2.14 / 2.44
2.00 / 2.29
1.82 / 2.08
1.72 / 1.97
1.88 / 2.15
1.72 / 1.97
1.70 / 2.02
1.67 / 1.91
2.38 / 2.72
Unit C
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
3.16 / 3.61
2.88 / 3.29
2.72 / 3.11
2.65 / 3.03
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20
2.20 / 2.52
2.20 / 2.51
2.12 / 2.43
1.93 / 2.20
1.81 / 2.07
1.70 / 1.94
2.20 / 2.52
2.08 / 2.38
1.89 / 2.16
1.78 / 2.03
1.67 / 1.91
1.95 / 2.23
1.78 / 2.03
1.68 / 1.92
2.18 / 2.50
2.04 / 2.33
1.86 / 2.12
1.75 / 2.00
1.91 / 2.19
1.75 / 2.00
1.80 / 2.06
2.43 / 2.78
2.27 / 2.60
2.07 / 2.37
1.96 / 2.23
2.13 / 2.44
1.96 / 2.23
2.00 / 2.30
2.66 / 3.04
2.38 / 2.72
Unit D
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
3.38 / 3.86
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
4.00 / 4.57
3.78 / 4.32
3.16 / 3.61
2.88 / 3.29
2.72 / 3.11
3.78 / 4.32
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20
2.20 / 2.52
2.20 / 2.51
2.12 / 2.43
1.93 / 2.20
1.81 / 2.07
1.70 / 1.94
2.20 / 2.52
2.08 / 2.38
1.89 / 2.16
1.78 / 2.03
1.67 / 1.91
1.95 / 2.23
1.78 / 2.03
1.68 / 1.92
2.48 / 2.84
2.32 / 2.65
2.11 / 2.41
1.99 / 2.27
2.17 / 2.48
1.99 / 2.27
2.87 / 3.27
2.43 / 2.78
2.27 / 2.60
2.07 / 2.37
1.96 / 2.23
2.13 / 2.44
1.96 / 2.23
2.82 / 3.22
2.66 / 3.04
2.38 / 2.72
Unit E
2.50 / 2.86
3.50 / 3.99
4.67 / 5.33
5.25 / 6.00
5.81 / 6.64
3.38 / 3.86
4.38 / 5.00
4.94 / 5.65
5.49 / 6.28
4.00 / 4.57
4.54 / 5.19
3.16 / 3.61
4.12 / 4.71
4.67 / 5.33
3.78 / 4.32
2.97 / 3.39
3.89 / 4.44
2.80 / 3.20
2.20 / 2.52
2.20 / 2.51
2.12 / 2.43
1.93 / 2.20
1.81 / 2.07
1.70 / 1.94
2.50 / 2.86
2.36 / 2.70
2.15 / 2.45
2.02 / 2.31
1.90 / 2.17
3.10 / 3.54
2.83 / 3.24
2.68 / 3.06
2.48 / 2.84
2.32 / 2.65
2.11 / 2.41
1.99 / 2.27
3.04 / 3.48
2.78 / 3.18
2.87 / 3.27
2.43 / 2.78
2.27 / 2.60
2.07 / 2.37
1.96 / 2.23
2.99 / 3.41
2.74 / 3.13
2.82 / 3.22
2.66 / 3.04
2.38 / 2.72
Unit F
2.20 / 2.52
2.50 / 2.85
3.38 / 3.86
4.38 / 5.00
4.94 / 5.65
5.49 / 6.28
2.50 / 2.86
3.31 / 3.78
4.29 / 4.91
4.86 / 5.55
5.40 / 6.17
3.10 / 3.54
4.05 / 4.62
4.59 / 5.25
2.48 / 2.84
3.25 / 3.71
4.22 / 4.82
4.77 / 5.45
3.04 / 3.48
3.98 / 4.55
2.87 / 3.27
2.43 / 2.78
3.18 / 3.64
4.14 / 4.73
4.69 / 5.36
2.99 / 3.41
3.91 / 4.47
2.82 / 3.22
2.66 / 3.04
2.38 / 2.72
Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 50
1 ROOM22
25
35
50
60
71
100
2 ROOMS22 + 22
22 + 25
22 + 35
22 + 50
22 + 60
22 + 71
22 + 100
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
25 + 100
35 + 35
35 + 50
35 + 60
35 + 71
35 + 100
50 + 50
50 + 60
50 + 71
50 + 100
60 + 60
60 + 71
60 + 100
71 + 71
71 + 100
100 + 100
3 ROOMS22 + 22 + 22
22 + 22 + 25
22 + 22 + 35
22 + 22 + 50
22 + 22 + 60
22 + 22 + 71
22 + 22 + 100
Unit A
2.20 / 3.30
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
10.00 / 11.20
2.20 / 2.55
2.20 / 2.57
2.20 / 2.55
2.20 / 2.57
2.20 / 2.55
2.20 / 2.55
2.20 / 2.56
2.50 / 2.90
2.50 / 2.92
2.50 / 2.90
2.50 / 2.91
2.50 / 2.89
2.50 / 2.90
3.50 / 4.05
3.50 / 4.08
3.50 / 4.05
3.50 / 4.06
3.50 / 4.07
5.00 / 5.80
5.00 / 5.82
5.00 / 5.83
4.67 / 6.00
6.00 / 6.95
6.00 / 6.96
5.25 / 6.75
7.00 / 9.00
5.81 / 7.47
7.00 / 9.00
2.20 / 2.57
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.56
2.14 / 2.75
Unit B
2.20 / 2.55
2.50 / 2.93
3.50 / 4.05
5.00 / 5.83
6.00 / 6.95
7.10 / 8.25
10.00 / 11.64
2.50 / 2.90
3.50 / 4.08
5.00 / 5.80
6.00 / 6.99
7.10 / 8.21
10.00 / 11.60
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
10.00 / 11.63
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
9.33 / 12.00
6.00 / 6.95
7.10 / 8.24
8.75 / 11.25
7.00 / 9.00
8.19 / 10.53
7.00 / 9.00
2.20 / 2.57
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.56
2.14 / 2.75
Unit C
2.20 / 2.57
2.50 / 2.90
3.50 / 4.08
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
9.72 / 12.50
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
MXZ-8B160YA1Outdoor Unit Up to 8 Indoor Units
22 + 25 + 25
22 + 25 + 35
22 + 25 + 50
22 + 25 + 60
22 + 25 + 71
22 + 25 + 100
22 + 35 + 35
22 + 35 + 50
22 + 35 + 60
22 + 35 + 71
22 + 35 + 100
22 + 50 + 50
22 + 50 + 60
22 + 50 + 71
22 + 50 + 100
22 + 60 + 60
22 + 60 + 71
22 + 60 + 100
22 + 71 + 71
22 + 71 + 100
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 25 + 100
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 35 + 100
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 50 + 100
25 + 60 + 60
25 + 60 + 71
25 + 60 + 100
25 + 71 + 71
25 + 71 + 100
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 35 + 100
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 50 + 100
35 + 60 + 60
Unit D
Indoor unitcombination
Cooling / Heating Capacity (kW)
35 + 60 + 71
35 + 60 + 100
35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 50 + 100
50 + 60 + 60
50 + 60 + 71
50 + 71 + 71
60 + 60 + 60
60 + 60 + 71
60 + 71 + 71
4 ROOMS22 + 22 + 22 + 22
22 + 22 + 22 + 25
22 + 22 + 22 + 35
22 + 22 + 22 + 50
22 + 22 + 22 + 60
22 + 22 + 22 + 71
22 + 22 + 22 + 100
22 + 22 + 25 + 25
22 + 22 + 25 + 35
22 + 22 + 25 + 50
22 + 22 + 25 + 60
22 + 22 + 25 + 71
22 + 22 + 25 + 100
22 + 22 + 35 + 35
22 + 22 + 35 + 50
22 + 22 + 35 + 60
22 + 22 + 35 + 71
22 + 22 + 35 + 100
22 + 22 + 50 + 50
22 + 22 + 50 + 60
22 + 22 + 50 + 71
22 + 22 + 50 + 100
22 + 22 + 60 + 60
22 + 22 + 60 + 71
22 + 22 + 71 + 71
22 + 25 + 25 + 25
22 + 25 + 25 + 35
22 + 25 + 25 + 50
22 + 25 + 25 + 60
22 + 25 + 25 + 71
22 + 25 + 25 + 100
22 + 25 + 35 + 35
22 + 25 + 35 + 50
22 + 25 + 35 + 60
Unit A
2.95 / 3.80
2.51 / 3.23
2.77 / 3.56
4.67 / 6.00
4.38 / 5.63
4.09 / 5.26
3.50 / 4.50
4.12 / 5.29
3.87 / 4.97
3.65 / 4.69
4.67 / 6.00
4.40 / 5.65
4.16 / 5.35
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.55
1.86 / 2.39
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.83
1.82 / 2.34
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.05 / 2.64
1.72 / 2.21
2.14 / 2.75
2.00 / 2.57
1.87 / 2.40
1.59 / 2.04
1.88 / 2.41
1.76 / 2.26
1.66 / 2.13
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.15 / 2.77
1.79 / 2.30
2.20 / 2.56
2.20 / 2.55
2.17 / 2.79
Unit B
5.06 / 6.51
4.31 / 5.54
5.62 / 7.22
4.67 / 6.00
4.38 / 5.63
4.09 / 5.26
3.50 / 4.50
4.94 / 6.35
4.64 / 5.97
5.18 / 6.66
4.67 / 6.00
4.40 / 5.65
4.92 / 6.33
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.55
1.86 / 2.39
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.83
1.82 / 2.34
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.05 / 2.64
1.72 / 2.21
2.14 / 2.75
2.00 / 2.57
1.87 / 2.40
1.59 / 2.04
1.88 / 2.41
1.76 / 2.26
1.66 / 2.13
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.45 / 3.15
2.03 / 2.62
2.50 / 2.91
2.50 / 2.90
2.46 / 3.17
Unit C
5.99 / 7.70
7.18 / 9.23
5.62 / 7.22
4.67 / 6.00
5.25 / 6.75
5.81 / 7.47
7.00 / 9.00
4.94 / 6.35
5.49 / 7.06
5.18 / 6.66
4.67 / 6.00
5.20 / 6.69
4.92 / 6.33
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.55
1.86 / 2.39
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 3.21
2.07 / 2.66
3.50 / 4.05
3.50 / 4.07
3.50 / 4.05
3.27 / 4.20
2.74 / 3.52
4.86 / 6.25
4.55 / 5.84
4.24 / 5.45
3.61 / 4.64
5.12 / 6.59
4.80 / 6.17
5.34 / 6.87
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.45 / 3.15
2.03 / 2.62
3.50 / 4.07
3.50 / 4.06
3.45 / 4.44
Unit D
2.20 / 2.55
2.50 / 2.91
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
8.43 / 10.84
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
6.00 / 6.98
7.10 / 9.13
8.28 / 10.65
3.50 / 4.05
5.00 / 5.81
6.00 / 6.95
6.63 / 8.52
7.82 / 10.06
4.86 / 6.25
5.45 / 7.01
6.02 / 7.75
7.22 / 9.28
5.12 / 6.59
5.68 / 7.30
5.34 / 6.87
2.50 / 2.91
3.50 / 4.06
5.00 / 5.82
6.00 / 6.95
6.95 / 8.94
8.14 / 10.47
3.50 / 4.07
5.00 / 5.80
5.92 / 7.61
Indoor unitcombination
Cooling / Heating Capacity (kW)
22 + 25 + 35 + 71
22 + 25 + 35 + 100
22 + 25 + 50 + 50
22 + 25 + 50 + 60
22 + 25 + 50 + 71
22 + 25 + 50 + 100
22 + 25 + 60 + 60
22 + 25 + 60 + 71
22 + 25 + 71 + 71
22 + 35 + 35 + 35
22 + 35 + 35 + 50
22 + 35 + 35 + 60
22 + 35 + 35 + 71
22 + 35 + 35 + 100
22 + 35 + 50 + 50
22 + 35 + 50 + 60
22 + 35 + 50 + 71
22 + 35 + 60 + 60
22 + 35 + 60 + 71
22 + 35 + 71 + 71
22 + 50 + 50 + 50
22 + 50 + 50 + 60
22 + 50 + 50 + 71
22 + 50 + 60 + 60
22 + 60 + 60 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 25 + 100
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 35 + 100
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 50 + 100
25 + 25 + 60 + 60
25 + 25 + 60 + 71
25 + 25 + 71 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 35 + 100
25 + 35 + 50 + 50
25 + 35 + 50 + 60
Unit A
2.01 / 2.59
1.69 / 2.18
2.10 / 2.69
1.96 / 2.52
1.83 / 2.36
1.56 / 2.01
1.84 / 2.37
1.73 / 2.22
1.63 / 2.10
2.20 / 2.55
2.17 / 2.79
2.03 / 2.61
1.89 / 2.43
1.60 / 2.06
1.96 / 2.52
1.84 / 2.37
1.73 / 2.22
1.74 / 2.24
1.64 / 2.11
1.55 / 1.99
1.79 / 2.30
1.69 / 2.18
1.60 / 2.05
1.60 / 2.06
1.52 / 1.96
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.40 / 3.08
2.00 / 2.57
2.50 / 2.90
2.50 / 2.91
2.41 / 3.10
2.24 / 2.88
1.89 / 2.43
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
2.06 / 2.65
1.93 / 2.49
1.82 / 2.34
2.50 / 2.90
2.41 / 3.10
2.26 / 2.90
2.11 / 2.71
1.79 / 2.31
2.19 / 2.81
2.06 / 2.65
Unit B
2.29 / 2.94
1.92 / 2.47
2.38 / 3.06
2.23 / 2.87
2.08 / 2.68
1.78 / 2.28
2.10 / 2.69
1.97 / 2.53
1.85 / 2.38
3.50 / 4.05
3.45 / 4.44
3.22 / 4.14
3.01 / 3.87
2.55 / 3.28
3.12 / 4.01
2.93 / 3.77
2.75 / 3.54
2.77 / 3.56
2.61 / 3.35
2.46 / 3.17
4.07 / 5.23
3.85 / 4.95
3.63 / 4.66
3.65 / 4.69
4.16 / 5.35
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.40 / 3.08
2.00 / 2.57
2.50 / 2.90
2.50 / 2.91
2.41 / 3.10
2.24 / 2.88
1.89 / 2.43
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
2.06 / 2.65
1.93 / 2.49
1.82 / 2.34
3.50 / 4.07
3.38 / 4.34
3.16 / 4.06
2.95 / 3.80
2.51 / 3.23
3.06 / 3.94
2.88 / 3.71
Unit C
3.20 / 4.12
2.69 / 3.46
4.76 / 6.12
4.46 / 5.73
4.17 / 5.36
3.55 / 4.57
5.03 / 6.47
4.72 / 6.07
5.26 / 6.76
3.50 / 4.05
3.45 / 4.44
3.22 / 4.14
3.01 / 3.87
2.55 / 3.28
4.46 / 5.73
4.19 / 5.39
3.93 / 5.06
4.75 / 6.10
4.47 / 5.74
4.99 / 6.42
4.07 / 5.23
3.85 / 4.95
3.63 / 4.66
4.38 / 5.63
4.16 / 5.35
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.40 / 3.08
2.00 / 2.57
3.50 / 4.05
3.50 / 4.07
3.38 / 4.34
3.14 / 4.04
2.65 / 3.41
4.67 / 6.00
4.38 / 5.63
4.09 / 5.26
3.50 / 4.50
4.94 / 6.35
4.64 / 5.97
5.18 / 6.66
3.50 / 4.07
3.38 / 4.34
3.16 / 4.06
2.95 / 3.80
2.51 / 3.23
4.38 / 5.63
4.12 / 5.29
Unit D
6.50 / 8.35
7.69 / 9.89
4.76 / 6.12
5.35 / 6.88
5.92 / 7.61
7.11 / 9.14
5.03 / 6.47
5.58 / 7.18
5.26 / 6.76
3.50 / 4.05
4.93 / 6.34
5.53 / 7.11
6.10 / 7.84
7.29 / 9.38
4.46 / 5.73
5.03 / 6.47
5.58 / 7.18
4.75 / 6.10
5.29 / 6.80
4.99 / 6.42
4.07 / 5.23
4.62 / 5.93
5.15 / 6.62
4.38 / 5.63
4.16 / 5.35
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
6.00 / 6.98
6.81 / 8.75
8.00 / 10.29
3.50 / 4.05
5.00 / 5.81
5.79 / 7.45
6.37 / 8.19
7.57 / 9.73
4.67 / 6.00
5.25 / 6.75
5.81 / 7.47
7.00 / 9.00
4.94 / 6.35
5.49 / 7.06
5.18 / 6.66
3.50 / 4.07
4.83 / 6.21
5.42 / 6.97
5.99 / 7.70
7.18 / 9.23
4.38 / 5.63
4.94 / 6.35
Indoor unitcombination
Cooling / Heating Capacity (kW)
Unit A
2.20 / 2.57
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.20 / 2.55
2.10 / 2.69
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.56
1.96 / 2.52
2.20 / 2.56
2.20 / 2.55
2.15 / 2.77
1.79 / 2.30
2.17 / 2.79
2.01 / 2.59
1.69 / 2.18
1.88 / 2.41
1.60 / 2.05
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.33 / 3.00
2.50 / 2.89
2.50 / 2.91
2.50 / 2.90
2.50 /2.90
2.19 / 2.81
2.50 / 2.90
2.50 / 2.91
2.40 / 3.08
2.00 / 2.57
2.41 / 3.10
2.24 / 2.88
1.89 / 2.43
2.10 / 2.69
1.79 / 2.30
3.50 / 4.07
3.50 / 4.05
3.50 / 4.07
3.48 / 4.47
2.88 / 3.71
3.50 / 4.07
3.38 / 4.34
3.14 / 4.04
2.65 / 3.41
3.16 / 4.06
Unit B
2.50 / 2.92
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.90
2.38 / 3.06
3.50 / 4.07
3.50 / 4.06
3.50 / 4.07
3.50 / 4.07
3.12 / 4.01
5.00 / 5.82
5.00 / 5.80
4.90 / 6.29
4.07 / 5.23
5.92 / 7.61
5.49 / 7.06
4.62 / 5.93
6.06 / 7.79
5.15 / 6.62
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.33 / 3.00
3.50 / 4.05
3.50 / 4.07
3.50 / 4.05
3.50 / 4.06
3.06 / 3.94
5.00 / 5.80
5.00 / 5.81
4.79 / 6.16
4.00 / 5.14
5.79 / 7.45
5.38 / 6.92
4.54 / 5.84
5.95 / 7.65
5.07 / 6.52
3.50 / 4.07
3.50 / 4.05
3.50 / 4.07
3.48 / 4.47
2.88 / 3.71
5.00 / 5.81
4.83 / 6.21
4.49 / 5.77
3.78 / 4.86
5.42 / 6.97
Unit C
2.50 / 2.92
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
9.52 / 12.24
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
7.10 / 8.26
8.92 / 11.46
5.00 / 5.82
6.00 / 6.95
6.95 / 8.94
8.14 / 10.47
5.92 / 7.61
6.50 / 8.35
7.69 / 9.89
6.06 / 7.79
7.25 / 9.33
2.50 / 2.90
3.50 / 4.08
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
9.33 / 12.00
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
8.75 / 11.25
5.00 / 5.80
6.00 / 6.98
6.81 / 8.75
8.00 / 10.29
5.79 / 7.45
6.37 / 8.19
7.57 / 9.73
5.95 / 7.65
7.14 / 9.18
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
7.05 / 9.06
8.24 / 10.59
5.00 / 5.81
5.79 / 7.45
6.37 / 8.19
7.57 / 9.73
5.42 / 6.97
Page 53Page 52
25 + 35 + 50 + 71
25 + 35 + 60 + 60
25 + 35 + 60 + 71
25 + 35 + 71 + 71
25 + 50 + 50 + 50
25 + 50 + 50 + 60
25 + 50 + 50 + 71
25 + 50 + 60 + 60
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50
35 + 35 + 50 + 60
35 + 35 + 50 + 71
35 + 35 + 60 + 60
35 + 35 + 60 + 71
35 + 50 + 50 + 50
35 + 50 + 50 + 60
50 + 50 + 50 + 50
5 ROOMS22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 22 + 100
22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 25 + 100
22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 35 + 71
22 + 22 + 22 + 35 + 100
22 + 22 + 22 + 50 + 50
22 + 22 + 22 + 50 + 60
22 + 22 + 22 + 50 + 71
22 + 22 + 22 + 60 + 60
22 + 22 + 22 + 60 + 71
22 + 22 + 25 + 25 + 25
22 + 22 + 25 + 25 + 35
22 + 22 + 25 + 25 + 50
22 + 22 + 25 + 25 + 60
Unit A
1.93 / 2.49
1.94 / 2.50
1.83 / 2.36
1.73 / 2.23
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
1.79 / 2.31
3.50 / 4.50
3.16 / 4.06
2.97 / 3.82
2.78 / 3.58
2.88 / 3.71
2.72 / 3.50
2.57 / 3.30
2.58 / 3.32
2.44 / 3.13
2.65 / 3.41
2.51 / 3.23
3.50 / 4.50
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.08 / 2.68
1.94 / 2.49
1.64 / 2.11
2.20 / 2.56
2.20 / 2.55
2.18 / 2.81
2.04 / 2.62
1.90 / 2.44
1.61 / 2.07
2.20 / 2.56
2.04 / 2.62
1.91 / 2.46
1.79 / 2.30
1.53 / 1.97
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.66 / 2.13
1.56 / 2.01
2.20 / 2.55
2.20 / 2.56
2.14 / 2.75
2.00 / 2.57
Unit B
2.71 / 3.48
2.72 / 3.50
2.57 / 3.30
2.43 / 3.12
4.00 / 5.14
3.78 / 4.86
3.57 / 4.59
3.59 / 4.62
3.50 / 4.50
3.16 / 4.06
2.97 / 3.82
2.78 / 3.58
2.88 / 3.71
2.72 / 3.50
2.57 / 3.30
2.58 / 3.32
2.44 / 3.13
3.78 / 4.86
3.59 / 4.62
3.50 / 4.50
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.08 / 2.68
1.94 / 2.49
1.64 / 2.11
2.20 / 2.56
2.20 / 2.55
2.18 / 2.81
2.04 / 2.62
1.90 / 2.44
1.61 / 2.07
2.20 / 2.56
2.04 / 2.62
1.91 / 2.46
1.79 / 2.30
1.53 / 1.97
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.66 / 2.13
1.56 / 2.01
2.20 / 2.55
2.20 / 2.56
2.14 / 2.75
2.00 / 2.57
Unit C
3.87 / 4.97
4.67 / 6.00
4.40 / 5.65
4.92 / 6.33
4.00 / 5.14
3.78 / 4.86
3.57 / 4.59
4.31 / 5.54
3.50 / 4.50
3.16 / 4.06
2.97 / 3.82
2.78 / 3.58
4.12 / 5.29
3.89 / 5.00
3.66 / 4.71
4.42 / 5.68
4.18 / 5.37
3.78 / 4.86
3.59 / 4.62
3.50 / 4.50
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.08 / 2.68
1.94 / 2.49
1.64 / 2.11
2.20 / 2.56
2.20 / 2.55
2.18 / 2.81
2.04 / 2.62
1.90 / 2.44
1.61 / 2.07
2.20 / 2.56
2.04 / 2.62
1.91 / 2.46
1.79 / 2.30
1.53 / 1.97
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.66 / 2.13
1.56 / 2.01
2.50 / 2.90
2.50 / 2.91
2.43 / 3.13
2.27 / 2.92
Unit D
5.49 / 7.06
4.67 / 6.00
5.20 / 6.69
4.92 / 6.33
4.00 / 5.14
4.54 / 5.84
5.07 / 6.52
4.31 / 5.54
3.50 / 4.50
4.52 / 5.81
5.09 / 6.55
5.65 / 7.26
4.12 / 5.29
4.67 / 6.00
5.20 / 6.69
4.42 / 5.68
4.95 / 6.36
3.78 / 4.86
4.31 / 5.54
3.50 / 4.50
2.20 / 2.56
2.20 / 2.55
2.20 / 2.56
2.20 / 2.55
2.08 / 2.68
1.94 / 2.49
1.64 / 2.11
2.50 / 2.91
2.50 / 2.90
2.48 / 3.19
2.32 / 2.98
2.16 / 2.78
1.83 / 2.36
3.50 / 4.07
3.25 / 4.17
3.04 / 3.91
2.85 / 3.66
2.44 / 3.13
4.22 / 5.42
3.98 / 5.11
3.74 / 4.81
4.52 / 5.81
4.26 / 5.48
2.50 / 2.90
2.50 / 2.91
2.43 / 3.13
2.27 / 2.92
Unit E
2.20 / 2.56
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
5.68 / 7.30
6.25 / 8.04
7.45 / 9.57
2.50 / 2.91
3.50 / 4.06
4.96 / 6.38
5.56 / 7.15
6.14 / 7.89
7.33 / 9.42
3.50 / 4.07
4.64 / 5.96
5.22 / 6.71
5.78 / 7.43
6.97 / 8.96
4.22 / 5.42
4.77 / 6.14
5.32 / 6.83
4.52 / 5.81
5.05 / 6.49
2.50 / 2.90
3.50 / 4.07
4.86 / 6.25
5.45 / 7.01
Unit F Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
22 + 22 + 25 + 25 + 71
22 + 22 + 25 + 25 + 100
22 + 22 + 25 + 35 + 35
22 + 22 + 25 + 35 + 50
22 + 22 + 25 + 35 + 60
22 + 22 + 25 + 35 + 71
22 + 22 + 25 + 50 + 50
22 + 22 + 25 + 50 + 60
22 + 22 + 25 + 50 + 71
22 + 22 + 25 + 60 + 60
22 + 22 + 25 + 60 + 71
22 + 22 + 35 + 35 + 35
22 + 22 + 35 + 35 + 50
22 + 22 + 35 + 35 + 60
22 + 22 + 35 + 35 + 71
22 + 22 + 35 + 50 + 50
22 + 22 + 35 + 50 + 60
22 + 22 + 35 + 50 + 71
22 + 22 + 35 + 60 + 60
22 + 22 + 50 + 50 + 50
22 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 71
22 + 25 + 25 + 25 + 100
22 + 25 + 25 + 35 + 35
22 + 25 + 25 + 35 + 50
22 + 25 + 25 + 35 + 60
22 + 25 + 25 + 35 + 71
22 + 25 + 25 + 50 + 50
22 + 25 + 25 + 50 + 60
22 + 25 + 25 + 50 + 71
22 + 25 + 25 + 60 + 60
22 + 25 + 35 + 35 + 35
22 + 25 + 35 + 35 + 50
22 + 25 + 35 + 35 + 60
22 + 25 + 35 + 35 + 71
22 + 25 + 35 + 50 + 50
22 + 25 + 35 + 50 + 60
22 + 25 + 35 + 60 + 60
22 + 25 + 50 + 50 + 50
22 + 35 + 35 + 35 + 35
22 + 35 + 35 + 35 + 50
22 + 35 + 35 + 35 + 60
22 + 35 + 35 + 35 + 71
22 + 35 + 35 + 50 + 50
22 + 35 + 35 + 50 + 60
25 + 25 + 25 + 25 + 25
Unit A
1.87 / 2.40
1.59 / 2.04
2.20 / 2.55
2.00 / 2.57
1.88 / 2.41
1.76 / 2.26
1.82 / 2.34
1.72 / 2.21
1.62 / 2.08
1.63 / 2.10
1.54 / 1.98
2.07 / 2.66
1.88 / 2.41
1.77 / 2.28
1.66 / 2.14
1.72 / 2.21
1.63 / 2.10
1.54 / 1.98
1.55 / 1.99
1.59 / 2.04
2.20 / 2.56
2.20 / 2.55
2.10 / 2.69
1.96 / 2.52
1.83 / 2.36
1.56 / 2.01
2.17 / 2.79
1.96 / 2.52
1.84 / 2.37
1.73 / 2.22
1.79 / 2.30
1.69 / 2.18
1.60 / 2.05
1.60 / 2.06
2.03 / 2.61
1.84 / 2.37
1.74 / 2.24
1.64 / 2.11
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.56 / 2.01
1.90 / 2.44
1.74 / 2.24
1.65 / 2.12
1.56 / 2.00
1.60 / 2.06
1.52 / 1.96
2.50 / 2.90
Unit B
1.87 / 2.40
1.59 / 2.04
2.20 / 2.55
2.00 / 2.57
1.88 / 2.41
1.76 / 2.26
1.82 / 2.34
1.72 / 2.21
1.62 / 2.08
1.63 / 2.10
1.54 / 1.98
2.07 / 2.66
1.88 / 2.41
1.77 / 2.28
1.66 / 2.14
1.72 / 2.21
1.63 / 2.10
1.54 / 1.98
1.55 / 1.99
1.59 / 2.04
2.50 / 2.91
2.50 / 2.90
2.38 / 3.06
2.23 / 2.87
2.08 / 2.68
1.78 / 2.28
2.46 / 3.17
2.23 / 2.87
2.10 / 2.69
1.97 / 2.53
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
1.82 / 2.34
2.30 / 2.96
2.10 / 2.69
1.98 / 2.54
1.86 / 2.39
1.92 / 2.47
1.82 / 2.34
1.73 / 2.23
1.78 / 2.28
3.02 / 3.89
2.77 / 3.56
2.62 / 3.37
2.47 / 3.18
2.55 / 3.28
2.43 / 3.12
2.50 / 2.90
Unit C
2.12 / 2.73
1.80 / 2.32
2.50 / 2.90
2.27 / 2.92
2.13 / 2.74
2.00 / 2.57
2.07 / 2.66
1.96 / 2.51
1.84 / 2.37
1.85 / 2.38
1.75 / 2.25
3.29 / 4.23
2.99 / 3.84
2.82 / 3.62
2.65 / 3.41
2.74 / 3.52
2.59 / 3.33
2.45 / 3.15
2.46 / 3.17
3.61 / 4.64
2.50 / 2.91
2.50 / 2.90
2.38 / 3.06
2.23 / 2.87
2.08 / 2.68
1.78 / 2.28
2.46 / 3.17
2.23 / 2.87
2.10 / 2.69
1.97 / 2.53
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
1.82 / 2.34
3.22 / 4.14
2.93 / 3.77
2.77 / 3.56
2.61 / 3.35
2.69 / 3.46
2.55 / 3.28
2.43 / 3.12
3.55 / 4.57
3.02 / 3.89
2.77 / 3.56
2.62 / 3.37
2.47 / 3.18
2.55 / 3.28
2.43 / 3.12
2.50 / 2.90
Unit D
2.12 / 2.73
1.80 / 2.32
3.50 / 4.05
3.18 / 4.09
2.99 / 3.84
2.80 / 3.60
4.14 / 5.33
3.91 / 5.03
3.68 / 4.74
4.44 / 5.71
4.20 / 5.40
3.29 / 4.23
2.99 / 3.84
2.82 / 3.62
2.65 / 3.41
3.91 / 5.03
3.70 / 4.76
3.50 / 4.50
4.22 / 5.43
3.61 / 4.64
2.50 / 2.91
2.50 / 2.90
2.38 / 3.06
2.23 / 2.87
2.08 / 2.68
1.78 / 2.28
3.45 / 4.44
3.12 / 4.01
2.93 / 3.77
2.75 / 3.54
4.07 / 5.23
3.85 / 4.95
3.63 / 4.66
4.38 / 5.63
3.22 / 4.14
2.93 / 3.77
2.77 / 3.56
2.61 / 3.35
3.85 / 4.95
3.65 / 4.69
4.16 / 5.35
3.55 / 4.57
3.02 / 3.89
2.77 / 3.56
2.62 / 3.37
2.47 / 3.18
3.65 / 4.69
3.47 / 4.46
2.50 / 2.90
Unit E
6.02 / 7.75
7.22 / 9.28
3.50 / 4.05
4.55 / 5.84
5.12 / 6.59
5.68 / 7.30
4.14 / 5.33
4.69 / 6.03
5.23 / 6.73
4.44 / 5.71
4.97 / 6.39
3.29 / 4.23
4.27 / 5.49
4.83 / 6.21
5.37 / 6.91
3.91 / 5.03
4.44 / 5.71
4.97 / 6.39
4.22 / 5.43
3.61 / 4.64
2.50 / 2.91
3.50 / 4.06
4.76 / 6.12
5.35 / 6.88
5.92 / 7.61
7.11 / 9.14
3.45 / 4.44
4.46 / 5.73
5.03 / 6.47
5.58 / 7.18
4.07 / 5.23
4.62 / 5.93
5.15 / 6.62
4.38 / 5.63
3.22 / 4.14
4.19 / 5.39
4.75 / 6.10
5.29 / 6.80
3.85 / 4.95
4.38 / 5.63
4.16 / 5.35
3.55 / 4.57
3.02 / 3.89
3.95 / 5.08
4.49 / 5.78
5.02 / 6.45
3.65 / 4.69
4.16 / 5.35
2.50 / 2.90
Unit F Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 55Page 54
22 + 22 + 22 + 25 + 25 + 50
22 + 22 + 22 + 25 + 25 + 60
22 + 22 + 22 + 25 + 25 + 71
22 + 22 + 22 + 25 + 35 + 35
22 + 22 + 22 + 25 + 35 + 50
22 + 22 + 22 + 25 + 35 + 60
22 + 22 + 22 + 25 + 35 + 71
22 + 22 + 22 + 25 + 50 + 50
22 + 22 + 22 + 25 + 50 + 60
22 + 22 + 22 + 35 + 35 + 35
22 + 22 + 22 + 35 + 35 + 50
22 + 22 + 22 + 35 + 35 + 60
22 + 22 + 22 + 35 + 50 + 50
22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 50
22 + 22 + 25 + 25 + 25 + 60
22 + 22 + 25 + 25 + 25 + 71
22 + 22 + 25 + 25 + 35 + 35
22 + 22 + 25 + 25 + 35 + 50
22 + 22 + 25 + 25 + 35 + 60
22 + 22 + 25 + 25 + 35 + 71
22 + 22 + 25 + 25 + 50 + 50
22 + 22 + 25 + 35 + 35 + 35
22 + 22 + 25 + 35 + 35 + 50
22 + 22 + 25 + 35 + 35 + 60
22 + 22 + 35 + 35 + 35 + 35
22 + 22 + 35 + 35 + 35 + 50
22 + 25 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 25 + 60
22 + 25 + 25 + 25 + 25 + 71
22 + 25 + 25 + 25 + 35 + 35
22 + 25 + 25 + 25 + 35 + 50
22 + 25 + 25 + 25 + 35 + 60
22 + 25 + 25 + 25 + 50 + 50
22 + 25 + 25 + 35 + 35 + 35
22 + 25 + 25 + 35 + 35 + 50
22 + 25 + 25 + 35 + 35 + 60
22 + 25 + 35 + 35 + 35 + 35
22 + 25 + 35 + 35 + 35 + 50
22 + 35 + 35 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 25 + 35 + 50
Unit A
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.91 / 2.46
1.75 / 2.25
1.66 / 2.13
1.56 / 2.01
1.61 / 2.07
1.53 / 1.97
1.80 / 2.32
1.66 / 2.13
1.57 / 2.02
1.53 / 1.97
2.14 / 2.75
2.00 / 2.57
1.82 / 2.34
1.72 / 2.21
1.62 / 2.08
1.88 / 2.41
1.72 / 2.21
1.63 / 2.10
1.54 / 1.98
1.59 / 2.04
1.77 / 2.28
1.63 / 2.10
1.55 / 1.99
1.67 / 2.15
1.55 / 1.99
2.10 / 2.69
1.96 / 2.52
1.79 / 2.30
1.69 / 2.18
1.60 / 2.05
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.56 / 2.01
1.74 / 2.24
1.60 / 2.06
1.52 / 1.96
1.65 / 2.12
1.52 / 1.96
1.56 / 2.01
2.33 / 3.00
2.19 / 2.81
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
2.06 / 2.65
1.89 / 2.43
Unit B
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.91 / 2.46
1.75 / 2.25
1.66 / 2.13
1.56 / 2.01
1.61 / 2.07
1.53 / 1.97
1.80 / 2.32
1.66 / 2.13
1.57 / 2.02
1.53 / 1.97
2.14 / 2.75
2.00 / 2.57
1.82 / 2.34
1.72 / 2.21
1.62 / 2.08
1.88 / 2.41
1.72 / 2.21
1.63 / 2.10
1.54 / 1.98
1.59 / 2.04
1.77 / 2.28
1.63 / 2.10
1.55 / 1.99
1.67 / 2.15
1.55 / 1.99
2.38 / 3.06
2.23 / 2.87
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
2.10 / 2.69
1.92 / 2.47
1.82 / 2.34
1.78 / 2.28
1.98 / 2.54
1.82 / 2.34
1.73 / 2.23
1.87 / 2.41
1.73 / 2.23
2.49 / 3.20
2.33 / 3.00
2.19 / 2.81
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
2.06 / 2.65
1.89 / 2.43
Unit C
1.86 / 2.39
1.75 / 2.25
1.65 / 2.12
1.91 / 2.46
1.75 / 2.25
1.66 / 2.13
1.56 / 2.01
1.61 / 2.07
1.53 / 1.97
1.80 / 2.32
1.66 / 2.13
1.57 / 2.02
1.53 / 1.97
2.43 / 3.13
2.27 / 2.92
2.07 / 2.66
1.96 / 2.51
1.84 / 2.37
2.13 / 2.74
1.96 / 2.51
1.85 / 2.38
1.75 / 2.25
1.80 / 2.32
2.01 / 2.59
1.85 / 2.38
1.76 / 2.26
2.66 / 3.42
2.46 / 3.17
2.38 / 3.06
2.23 / 2.87
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
2.10 / 2.69
1.92 / 2.47
1.82 / 2.34
1.78 / 2.28
1.98 / 2.54
1.82 / 2.34
1.73 / 2.23
2.62 / 3.37
2.43 / 3.12
2.49 / 3.20
2.33 / 3.00
2.19 / 2.81
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
2.06 / 2.65
1.89 / 2.43
Unit D
2.11 / 2.71
1.99 / 2.56
1.87 / 2.41
2.17 / 2.80
1.99 / 2.56
1.88 / 2.42
1.78 / 2.28
1.83 / 2.36
1.74 / 2.24
2.87 / 3.68
2.63 / 3.39
2.50 / 3.21
2.44 / 3.13
2.43 / 3.13
2.27 / 2.92
2.07 / 2.66
1.96 / 2.51
1.84 / 2.37
2.13 / 2.74
1.96 / 2.51
1.85 / 2.38
1.75 / 2.25
1.80 / 2.32
2.82 / 3.62
2.59 / 3.33
2.46 / 3.17
2.66 / 3.42
2.46 / 3.17
2.38 / 3.06
2.23 / 2.87
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
2.10 / 2.69
1.92 / 2.47
1.82 / 2.34
1.78 / 2.28
2.77 / 3.56
2.55 / 3.28
2.43 / 3.12
2.62 / 3.37
2.43 / 3.12
2.49 / 3.20
2.33 / 3.00
2.19 / 2.81
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
2.06 / 2.65
1.89 / 2.43
Unit E
2.11 / 2.71
1.99 / 2.56
1.87 / 2.41
3.04 / 3.91
2.78 / 3.58
2.63 / 3.39
2.49 / 3.20
3.66 / 4.71
3.48 / 4.48
2.87 / 3.68
2.63 / 3.39
2.50 / 3.21
3.48 / 4.48
2.43 / 3.13
2.27 / 2.92
2.07 / 2.66
1.96 / 2.51
1.84 / 2.37
2.99 / 3.84
2.74 / 3.52
2.59 / 3.33
2.45 / 3.15
3.61 / 4.64
2.82 / 3.62
2.59 / 3.33
2.46 / 3.17
2.66 / 3.42
2.46 / 3.17
2.38 / 3.06
2.23 / 2.87
2.03 / 2.62
1.92 / 2.47
1.81 / 2.33
2.93 / 3.77
2.69 / 3.46
2.55 / 3.28
3.55 / 4.57
2.77 / 3.56
2.55 / 3.28
2.43 / 3.12
2.62 / 3.37
2.43 / 3.12
2.49 / 3.20
2.33 / 3.00
2.19 / 2.81
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
2.88 / 3.71
2.65 / 3.41
Unit F
4.22 / 5.42
4.77 / 6.14
5.32 / 6.83
3.04 / 3.91
3.98 / 5.11
4.52 / 5.81
5.05 / 6.49
3.66 / 4.71
4.18 / 5.37
2.87 / 3.68
3.76 / 4.84
4.29 / 5.51
3.48 / 4.48
2.43 / 3.13
3.18 / 4.09
4.14 / 5.33
4.69 / 6.03
5.23 / 6.73
2.99 / 3.84
3.91 / 5.03
4.44 / 5.71
4.97 / 6.39
3.61 / 4.64
2.82 / 3.62
3.70 / 4.76
4.22 / 5.43
2.66 / 3.42
3.52 / 4.52
2.38 / 3.06
3.12 / 4.01
4.07 / 5.23
4.62 / 5.93
5.15 / 6.62
2.93 / 3.77
3.85 / 4.95
4.38 / 5.63
3.55 / 4.57
2.77 / 3.56
3.65 / 4.69
4.16 / 5.35
2.62 / 3.37
3.47 / 4.46
2.49 / 3.20
2.33 / 3.00
3.06 / 3.94
4.00 / 5.14
4.54 / 5.84
5.07 / 6.52
2.88 / 3.71
3.78 / 4.86
Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 25 + 100
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 35 + 71
25 + 25 + 25 + 50 + 50
25 + 25 + 25 + 50 + 60
25 + 25 + 25 + 50 + 71
25 + 25 + 25 + 60 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 25 + 35 + 35 + 71
25 + 25 + 35 + 50 + 50
25 + 25 + 35 + 50 + 60
25 + 25 + 50 + 50 + 50
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
25 + 35 + 35 + 35 + 60
25 + 35 + 35 + 35 + 71
25 + 35 + 35 + 50 + 50
35 + 35 + 35 + 35 + 35
35 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 60
6 ROOMS22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 22 + 71
22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 22 + 25 + 71
22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 22 + 35 + 60
22 + 22 + 22 + 22 + 35 + 71
22 + 22 + 22 + 22 + 50 + 50
22 + 22 + 22 + 22 + 50 + 60
22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 35
Unit A
2.50 / 2.91
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
2.41 / 3.10
2.19 / 2.81
2.06 / 2.65
1.93 / 2.49
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
1.79 / 2.31
2.26 / 2.90
2.06 / 2.65
1.94 / 2.50
1.83 / 2.36
1.89 / 2.43
1.79 / 2.31
1.75 / 2.25
2.12 / 2.73
1.94 / 2.50
1.84 / 2.37
1.74 / 2.24
1.79 / 2.31
2.80 / 3.60
2.58 / 3.32
2.45 / 3.15
2.20 / 2.55
2.20 / 2.56
2.12 / 2.73
1.93 / 2.48
1.81 / 2.33
1.70 / 2.19
2.20 / 2.55
2.08 / 2.68
1.89 / 2.43
1.78 / 2.29
1.67 / 2.15
1.95 / 2.51
1.78 / 2.29
1.68 / 2.16
1.59 / 2.04
1.64 / 2.11
1.56 / 2.00
2.18 / 2.81
2.04 / 2.62
Unit B
2.50 / 2.91
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
2.41 / 3.10
2.19 / 2.81
2.06 / 2.65
1.93 / 2.49
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
1.79 / 2.31
2.26 / 2.90
2.06 / 2.65
1.94 / 2.50
1.83 / 2.36
1.89 / 2.43
1.79 / 2.31
1.75 / 2.25
2.97 / 3.82
2.72 / 3.50
2.58 / 3.32
2.44 / 3.13
2.51 / 3.23
2.80 / 3.60
2.58 / 3.32
2.45 / 3.15
2.20 / 2.55
2.20 / 2.56
2.12 / 2.73
1.93 / 2.48
1.81 / 2.33
1.70 / 2.19
2.20 / 2.55
2.08 / 2.68
1.89 / 2.43
1.78 / 2.29
1.67 / 2.15
1.95 / 2.51
1.78 / 2.29
1.68 / 2.16
1.59 / 2.04
1.64 / 2.11
1.56 / 2.00
2.18 / 2.81
2.04 / 2.62
Unit C
2.50 / 2.91
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
2.41 / 3.10
2.19 / 2.81
2.06 / 2.65
1.93 / 2.49
2.00 / 2.57
1.89 / 2.43
1.79 / 2.30
1.79 / 2.31
3.16 / 4.06
2.88 / 3.71
2.72 / 3.50
2.57 / 3.30
2.65 / 3.41
2.51 / 3.23
3.50 / 4.50
2.97 / 3.82
2.72 / 3.50
2.58 / 3.32
2.44 / 3.13
2.51 / 3.23
2.80 / 3.60
2.58 / 3.32
2.45 / 3.15
2.20 / 2.55
2.20 / 2.56
2.12 / 2.73
1.93 / 2.48
1.81 / 2.33
1.70 / 2.19
2.20 / 2.55
2.08 / 2.68
1.89 / 2.43
1.78 / 2.29
1.67 / 2.15
1.95 / 2.51
1.78 / 2.29
1.68 / 2.16
1.59 / 2.04
1.64 / 2.11
1.56 / 2.00
2.18 / 2.81
2.04 / 2.62
Unit D
2.50 / 2.91
2.33 / 3.00
2.19 / 2.81
2.05 / 2.63
1.75 / 2.25
3.38 / 4.34
3.06 / 3.94
2.88 / 3.71
2.71 / 3.48
4.00 / 5.14
3.78 / 4.86
3.57 / 4.59
4.31 / 5.54
3.16 / 4.06
2.88 / 3.71
2.72 / 3.50
2.57 / 3.30
3.78 / 4.86
3.59 / 4.62
3.50 / 4.50
2.97 / 3.82
2.72 / 3.50
2.58 / 3.32
2.44 / 3.13
3.59 / 4.62
2.80 / 3.60
2.58 / 3.32
2.45 / 3.15
2.20 / 2.55
2.20 / 2.56
2.12 / 2.73
1.93 / 2.48
1.81 / 2.33
1.70 / 2.19
2.20 / 2.55
2.08 / 2.68
1.89 / 2.43
1.78 / 2.29
1.67 / 2.15
1.95 / 2.51
1.78 / 2.29
1.68 / 2.16
1.59 / 2.04
1.64 / 2.11
1.56 / 2.00
2.48 / 3.19
2.32 / 2.98
Unit E
3.50 / 4.07
4.67 / 6.00
5.25 / 6.75
5.81 / 7.47
7.00 / 9.00
3.38 / 4.34
4.38 / 5.63
4.94 / 6.35
5.49 / 7.06
4.00 / 5.14
4.54 / 5.84
5.07 / 6.52
4.31 / 5.54
3.16 / 4.06
4.12 / 5.29
4.67 / 6.00
5.20 / 6.69
3.78 / 4.86
4.31 / 5.54
3.50 / 4.50
2.97 / 3.82
3.89 / 5.00
4.42 / 5.68
4.95 / 6.36
3.59 / 4.62
2.80 / 3.60
3.68 / 4.74
4.20 / 5.40
2.20 / 2.55
2.20 / 2.56
2.12 / 2.73
1.93 / 2.48
1.81 / 2.33
1.70 / 2.19
2.50 / 2.90
2.36 / 3.04
2.15 / 2.76
2.02 / 2.60
1.90 / 2.45
3.10 / 3.99
2.83 / 3.64
2.68 / 3.44
2.53 / 3.25
3.72 / 4.79
3.54 / 4.55
2.48 / 3.19
2.32 / 2.98
Unit F
2.20 / 2.55
2.50 / 2.91
3.38 / 4.34
4.38 / 5.63
4.94 / 6.35
5.49 / 7.06
2.50 / 2.90
3.31 / 4.26
4.29 / 5.52
4.86 / 6.24
5.40 / 6.95
3.10 / 3.99
4.05 / 5.20
4.59 / 5.90
5.12 / 6.59
3.72 / 4.79
4.24 / 5.45
2.48 / 3.19
3.25 / 4.17
Unit G Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 57Page 56
8 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 22 + 22 + 25 + 25 + 35
22 + 22 + 22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 22 + 25 + 25 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 25 + 25
Unit A
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.66 / 2.14
1.58 / 2.03
1.64 / 2.11
1.56 / 2.00
1.61 / 2.07
1.53 / 1.97
1.59 / 2.04
1.56 / 2.01
1.75 / 2.25
Unit B
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.66 / 2.14
1.58 / 2.03
1.64 / 2.11
1.56 / 2.00
1.61 / 2.07
1.53 / 1.97
1.59 / 2.04
1.78 / 2.28
1.75 / 2.25
Unit C
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.66 / 2.14
1.58 / 2.03
1.64 / 2.11
1.56 / 2.00
1.61 / 2.07
1.53 / 1.97
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Unit D
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.66 / 2.14
1.58 / 2.03
1.64 / 2.11
1.56 / 2.00
1.83 / 2.36
1.74 / 2.24
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Unit E
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.66 / 2.14
1.58 / 2.03
1.86 / 2.39
1.77 / 2.27
1.83 / 2.36
1.74 / 2.24
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Unit F
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.69 / 2.18
1.60 / 2.06
1.52 / 1.96
1.89 / 2.43
1.79 / 2.31
1.86 / 2.39
1.77 / 2.27
1.83 / 2.36
1.74 / 2.24
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Unit G
1.75 / 2.25
1.72 / 2.21
1.63 / 2.10
1.92 / 2.47
1.82 / 2.34
2.43 / 3.12
1.89 / 2.43
1.79 / 2.31
1.86 / 2.39
1.77 / 2.27
1.83 / 2.36
1.74 / 2.24
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Unit H
1.75 / 2.25
1.96 / 2.51
2.59 / 3.33
1.92 / 2.47
2.55 / 3.28
2.43 / 3.12
1.89 / 2.43
2.51 / 3.23
1.86 / 2.39
2.47 / 3.18
1.83 / 2.36
2.44 / 3.13
1.80 / 2.32
1.78 / 2.28
1.75 / 2.25
Indoor unitcombination
Cooling / Heating Capacity (kW)
25 + 25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 25 + 50 + 50
25 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 35 + 35
7 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22
22 + 22 + 22 + 22 + 22 + 22 + 25
22 + 22 + 22 + 22 + 22 + 22 + 35
22 + 22 + 22 + 22 + 22 + 22 + 50
22 + 22 + 22 + 22 + 22 + 22 + 60
22 + 22 + 22 + 22 + 22 + 25 + 25
22 + 22 + 22 + 22 + 22 + 25 + 35
22 + 22 + 22 + 22 + 22 + 25 + 50
22 + 22 + 22 + 22 + 22 + 25 + 60
22 + 22 + 22 + 22 + 22 + 35 + 35
22 + 22 + 22 + 22 + 22 + 35 + 50
22 + 22 + 22 + 22 + 25 + 25 + 25
22 + 22 + 22 + 22 + 25 + 25 + 35
22 + 22 + 22 + 22 + 25 + 25 + 50
22 + 22 + 22 + 22 + 25 + 25 + 60
22 + 22 + 22 + 22 + 25 + 35 + 35
22 + 22 + 22 + 22 + 25 + 35 + 50
22 + 22 + 22 + 22 + 35 + 35 + 35
22 + 22 + 22 + 25 + 25 + 25 + 25
22 + 22 + 22 + 25 + 25 + 25 + 35
22 + 22 + 22 + 25 + 25 + 25 + 50
22 + 22 + 22 + 25 + 25 + 25 + 60
22 + 22 + 22 + 25 + 25 + 35 + 35
22 + 22 + 22 + 25 + 25 + 35 + 50
22 + 22 + 22 + 25 + 35 + 35 + 35
22 + 22 + 25 + 25 + 25 + 25 + 25
22 + 22 + 25 + 25 + 25 + 25 + 35
22 + 22 + 25 + 25 + 25 + 25 + 50
22 + 22 + 25 + 25 + 25 + 35 + 35
22 + 22 + 25 + 25 + 35 + 35 + 35
22 + 25 + 25 + 25 + 25 + 25 + 25
22 + 25 + 25 + 25 + 25 + 25 + 35
22 + 25 + 25 + 25 + 25 + 25 + 50
22 + 25 + 25 + 25 + 25 + 35 + 35
22 + 25 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 35 + 35
Unit A
1.79 / 2.31
1.75 / 2.25
1.94 / 2.50
1.79 / 2.31
1.84 / 2.37
1.75 / 2.25
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.93 / 2.48
1.81 / 2.33
1.66 / 2.14
1.58 / 2.03
1.71 / 2.20
1.58 / 2.03
1.89 / 2.43
1.78 / 2.29
1.64 / 2.11
1.56 / 2.00
1.68 / 2.16
1.56 / 2.00
1.60 / 2.05
1.86 / 2.39
1.75 / 2.25
1.61 / 2.07
1.53 / 1.97
1.66 / 2.13
1.53 / 1.97
1.57 / 2.02
1.82 / 2.34
1.72 / 2.21
1.59 / 2.04
1.63 / 2.10
1.55 / 1.99
1.79 / 2.30
1.69 / 2.18
1.56 / 2.01
1.60 / 2.06
1.52 / 1.96
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
1.79 / 2.31
Unit B
1.79 / 2.31
1.75 / 2.25
1.94 / 2.50
1.79 / 2.31
1.84 / 2.37
2.45 / 3.15
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.93 / 2.48
1.81 / 2.33
1.66 / 2.14
1.58 / 2.03
1.71 / 2.20
1.58 / 2.03
1.89 / 2.43
1.78 / 2.29
1.64 / 2.11
1.56 / 2.00
1.68 / 2.16
1.56 / 2.00
1.60 / 2.05
1.86 / 2.39
1.75 / 2.25
1.61 / 2.07
1.53 / 1.97
1.66 / 2.13
1.53 / 1.97
1.57 / 2.02
1.82 / 2.34
1.72 / 2.21
1.59 / 2.04
1.63 / 2.10
1.55 / 1.99
2.03 / 2.62
1.92 / 2.47
1.78 / 2.28
1.82 / 2.34
1.73 / 2.23
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
1.79 / 2.31
Unit C
1.79 / 2.31
1.75 / 2.25
1.94 / 2.50
1.79 / 2.31
2.58 / 3.32
2.45 / 3.15
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.93 / 2.48
1.81 / 2.33
1.66 / 2.14
1.58 / 2.03
1.71 / 2.20
1.58 / 2.03
1.89 / 2.43
1.78 / 2.29
1.64 / 2.11
1.56 / 2.00
1.68 / 2.16
1.56 / 2.00
1.60 / 2.05
1.86 / 2.39
1.75 / 2.25
1.61 / 2.07
1.53 / 1.97
1.66 / 2.13
1.53 / 1.97
1.57 / 2.02
2.07 / 2.66
1.96 / 2.51
1.80 / 2.32
1.85 / 2.38
1.76 / 2.26
2.03 / 2.62
1.92 / 2.47
1.78 / 2.28
1.82 / 2.34
1.73 / 2.23
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
1.79 / 2.31
Unit D
1.79 / 2.31
1.75 / 2.25
2.72 / 3.50
2.51 / 3.23
2.58 / 3.32
2.45 / 3.15
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.93 / 2.48
1.81 / 2.33
1.66 / 2.14
1.58 / 2.03
1.71 / 2.20
1.58 / 2.03
1.89 / 2.43
1.78 / 2.29
1.64 / 2.11
1.56 / 2.00
1.68 / 2.16
1.56 / 2.00
1.60 / 2.05
2.11 / 2.71
1.99 / 2.56
1.83 / 2.36
1.74 / 2.24
1.88 / 2.42
1.74 / 2.24
1.79 / 2.30
2.07 / 2.66
1.96 / 2.51
1.80 / 2.32
1.85 / 2.38
1.76 / 2.26
2.03 / 2.62
1.92 / 2.47
1.78 / 2.28
1.82 / 2.34
1.73 / 2.23
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
1.79 / 2.31
Unit E
2.51 / 3.23
3.50 / 4.50
2.72 / 3.50
2.51 / 3.23
2.58 / 3.32
2.45 / 3.15
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
1.93 / 2.48
1.81 / 2.33
1.66 / 2.14
1.58 / 2.03
1.71 / 2.20
1.58 / 2.03
2.15 / 2.76
2.02 / 2.60
1.86 / 2.39
1.77 / 2.27
1.91 / 2.46
1.77 / 2.27
2.54 / 3.26
2.11 / 2.71
1.99 / 2.56
1.83 / 2.36
1.74 / 2.24
1.88 / 2.42
1.74 / 2.24
2.50 / 3.21
2.07 / 2.66
1.96 / 2.51
1.80 / 2.32
1.85 / 2.38
2.46 / 3.17
2.03 / 2.62
1.92 / 2.47
1.78 / 2.28
1.82 / 2.34
2.43 / 3.12
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
1.79 / 2.31
Unit F
4.31 / 5.54
3.50 / 4.50
2.72 / 3.50
3.59 / 4.62
2.58 / 3.32
2.45 / 3.15
2.00 / 2.57
1.96 / 2.52
1.84 / 2.37
1.69 / 2.18
1.60 / 2.06
2.19 / 2.81
2.06 / 2.65
1.89 / 2.43
1.79 / 2.31
2.72 / 3.50
2.51 / 3.23
2.15 / 2.76
2.02 / 2.60
1.86 / 2.39
1.77 / 2.27
2.68 / 3.44
2.47 / 3.18
2.54 / 3.26
2.11 / 2.71
1.99 / 2.56
1.83 / 2.36
1.74 / 2.24
2.63 / 3.39
2.44 / 3.13
2.50 / 3.21
2.07 / 2.66
1.96 / 2.51
1.80 / 2.32
2.59 / 3.33
2.46 / 3.17
2.03 / 2.62
1.92 / 2.47
1.78 / 2.28
2.55 / 3.28
2.43 / 3.12
2.00 / 2.57
1.89 / 2.43
1.75 / 2.25
2.51 / 3.23
Unit G
2.00 / 2.57
2.23 / 2.87
2.93 / 3.77
3.85 / 4.95
4.38 / 5.63
2.19 / 2.81
2.88 / 3.71
3.78 / 4.86
4.31 / 5.54
2.72 / 3.50
3.59 / 4.62
2.15 / 2.76
2.83 / 3.64
3.72 / 4.79
4.24 / 5.45
2.68 / 3.44
3.54 / 4.55
2.54 / 3.26
2.11 / 2.71
2.78 / 3.58
3.66 / 4.71
4.18 / 5.37
2.63 / 3.39
3.48 / 4.48
2.50 / 3.21
2.07 / 2.66
2.74 / 3.52
3.61 / 4.64
2.59 / 3.33
2.46 / 3.17
2.03 / 2.62
2.69 / 3.46
3.55 / 4.57
2.55 / 3.28
2.43 / 3.12
2.00 / 2.57
2.65 / 3.41
3.50 / 4.50
2.51 / 3.23
Unit H
Indoor unitcombination
Cooling / Heating Capacity (kW)
Page 59Page 58
Out
door
Uni
t D
imen
sions
Side View >
417.5
40
175 500
330 50
Air in
Air out
360
840
109
81
880
452
99.5
164.
5
195
35
44
Front View >
Upper View >
Side View >Front View >
Upper View >
MUZ-GE50VA / SUZ-KA50VA2
MUZ-GE60/71VA
Dimensions
Page 61
M S
eri
es
Ran
geOutdoor Units
Side View >
MUZ-HC25/35VA(B)
MUZ-GE25/35VA / MUZ-FD25/35VABH / SUZ-KA25/35VA2
Upper View >
Front View >
Side View >
Upper View >
Front View >
Dimensions
Page 60
Acc
esso
ries
/ O
ptio
nal Ex
tras
Accessories / Optional ExtrasM Series
Catechin Filter MAC-3003CF - for MSZ-HC25/35VA(B) (10 pack)
Anti-Allergy Enzyme Filters MAC-408FT-E - for MSZ-GE22-50VA (10 pack)MAC-2310FT-E - for MSZ-GE60/71VA (10 pack)MAC-415FT-E - for MFZ-KA25-50VA (10 pack)
Wired Remote controller PAR-30MAA - for MSZ-GE22-71VA, MSZ-FD25/35VA & MFZ-KA25-50VA
Interfaces MAC-399IF - for connection to M-NET system
MAC-397IF - for Contact Terminal, PAR-30MAA Wired Remote Controller
Air Outlet Guides MAC-889SG - for MXZ-2C52VA, MUZ-HC, MUZ-GE & MUZ-FD
MAC-856SG - for MXZ-3C54VA, MXZ-4C71VA, MXZ-4C80VA & MXZ-5C100VA
PAC-SG59SG-E - for MXZ-8B140VA, MXZ-8B160YA
MXZ-8B Connection Pipe PAC-AK52YP-E - Y shaped pipe for MXZ-8B models enabling size 100 connection (PLA-RP)
Page 62
M S
eri
es
Ran
ge
Mr Sl im Packaged Split-SystemAir Conditioning
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
The Mr Slim RangeCompact and Versatile, theOptions are Endless
Suitable to heat or cool a huge variety of applications, the Mr Slimrange is one of Britain’s best selling air conditioning split-systems.Combine the efficiency with the complete versatility that thisrange has to offer and the possibilities are virtually infinite.
The 2011 Mr Slim range has been updated with new features, as well as the already impressiveefficiency levels being improved. New to the range is an improved Standard Inverter offering, nowalso available as a 3-phase option. Complementing this, the Mr Slim Zubadan Inverter range ofoutdoor units guarantee heating operation down to -25ºC ambient air temperature, allowing set temperatures to be reached faster.
The Mr Slim range has reached a new level of energy efficiency with the incorporation of newtechnologies and a new body design. These innovations will result in lower running costs andemissions throughout the life of a system. The side flow configuration of the outdoor unit,maximum piping length of 120m and Replace Technology help to simplify installation and make Mr Slim units more than just physically compact and discreet. They are also amongst the quietestoperating units available, which means that apart from enjoying a comfortable, controllableenvironment, users hardly know Mr Slim is there at all.
Easy to fitwhereveryou need
An installers favourite, the excellentdesign of the Mr Slim range ensuresquick and simple installation with theminimum of disruption. With extensive pipe runs of up to 120m, this versatilerange makes it easier to select a layout to install the unit.
Page 65Page 64
An HIC has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformedinto a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to thecompressor, thereby reducing the load on the compressor and raising efficiency.
Heat Interchanger Circuit (HIC) Added <RP140>
New
Increase in heat-exchanger
surface area
2 lines, 52 columns
2 lines, 64 columns
* 1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm,6 days/week / Operating period-Cooling: April 16 - November 8. Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA4.
Page 67
Power Inver terThe Mr Slim Power Inverter range is now stronger than ever.The technological developments applied to this range of equipment offer the end user some of the highest energy efficiency ratings available, alongside greater application flexibility.
Page 66
Improved COP / EER RatingsCOP and EER ratings have increased across the board withthe introduction of the VHA4 and VKA/YKA models. Manysystems within our range now having energy labels of ‘A’ inboth heating and cooling.
Existing R22/R407c Pipe WorkThe issue of using existing pipe work has been resolved usingMitsubishi Electric’s unique ‘Replace Technology’, offering theopportunity to upgrade older, less efficient systems with theminimum of cost and installation disruption.
Reducing Power Consumption by 70%The Mr Slim Power Inverter can reduce power consumptionby up to 70% compared to a previously installed non-invertermodel*1, making the energy cost savings associated with thisrange truly remarkable. A high power function also deliversincreased capacity at times of high demand, allowing the roomtarget temperature to be reached as rapidly as possible from start up.
This range is available in single and 3-phase options, the latterhaving running currents that are more than half that of the singlephase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have lowstarting currents of 5 amps.
Highly Efficient Fan and GrilleThe shapes of the fan and grille of the outdoor unit have beenredesigned, realising an increase in discharge volume and amore efficient heat exchange, while maintaining the sameoperating noise level.
Outdoor Unit Fan Opening Increased <RP100-250>
The diameter of the fanopening in the outdoor unithas been increased from490 to 550mm. Dischargevolume has been increased,while maintaining the samefan rotation speed.
Grille Shape Changed <RP60-250>
The shape of the air outlet grille has been changed to reducepressure loss. This has helped improve heat exchange performance.
Inflexed Fan <RP100-250>
The adoption of a fanwith improved ventilationcharacteristics and a newlydesigned rear edge thatsuppresses wind turbulenceraises fan operation efficiency.
Highly Efficient Heat ExchangerA reduction in pipe diameter and an increase in surface areahave improved the overall efficiency of the heat exchanger.
High-DensityHeat Exchanger <RP100-250>
The pipe diameter for theRP100-140 has been changed from 9.52 to 7.94mm, the same diameter as that used for RP200-250 units, resulting in a high-density heat exchanger.
Heat-Exchange Surface Area Increased <RP100-250>
The heat exchanger size has been extended horizontally,increasing the surface area.
*1 When comparing the Power Inverter (PUHZ-RP71VHA4) with R22 (PUH3-VKA) in cooling.
Silent OperationOperation has been made near-silent (67% quieterthan corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades andthe new grille shape. The Power Inverter is evenquieter at night when outside temperatures drop, as itcan be set to low-noise mode (cooling only) reducingoperating noise by 3dBA (50% quieter than normalday mode).
A low-noise priority function is also available byconnecting a separate commercially available timer or selector switch. When a signal is received from the timer or switch, the unit automatically runsin low-noise mode.
Pump down switch
Design with Environmental Consideration:
Low noise mode can be set at night time to reduce noise levels by approximately 50%.
The example here is usinga PUHZ-P100VHA3
1338mm
943mm
330mm 330mm
395mm
1050mm 950mm
PowerInverter
StandardInverter
116kg 75kg
Height reduced by 395mm
Weight reduced by 41kg
Day 50dBAOutdoor Temperature 35ºC
Night 47dBAOutdoor Temperature 25ºC
1/2 the audible sound(compared to
daytime)
3dBALess
Example:
Silent Outdoor Unit - Low Noise Mode
Page 69
Standard InverterThe Standard Inverter models provide an inverter solutionat a lower capital cost than the Power Inverter range. These outdoormodels continue to offer high efficiency as standard, with somesystems qualifying for Enhanced Capital Allowance.
Models are available in 10, 12.5 & 14kW single phase andnew for 2011, in 3-phase 10, 12.5, 14, 19 and 22kW sizes.
Page 68
Improved COP / EER Figures
COP / EER figures have been improved when compared to theprevious R407c range.
The 10kW model has a compact single fan design and weighsless when compared to its Power Inverter equivalent, makinginstallation easier.
Pump down switchPushing a switch starts / stops refrigerant recovery operation automatically. This process will then be completed by closing a valve.
New3-phase
models nowavailable
SUZ outdoor unitsare able to be connected
to selected Mr Slim indoorunits, creating a new range
of low cost inverter driven systems.
Smooth refrigerant recovery can be assured by pushing thepump down switch at unit movement / renewal.
Duty Standby Operation3 new functions are available with Mr Slim systems*1 :
*1 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-30MAA controller.
Rotation2 outdoor units (master & slave) operate alternately, switching every 1, 3, 5, 7, 14, 28 days (selectable).
Back UpWhen master outdoor unit fails, sub unit begins operation.
Join InWhen master outdoor unit fails to reach set temperature, sub unit operates in conjunction (available in cooling mode only).
Rotate
Back Up
Join In
Improved Fan Design and Weight
The Zubadan Series is equipped with Mitsubishi Electric’soriginal Flash Injection Circuit, which is comprised of a bypass circuit and heat interchanger (HIC). The HICtransforms re-routed liquid refrigerant into a gas-liquidstate to lower compression load. This process ensuresexcellent heating performance even when the outdoortemperature drops very low.
In traditional units, when the outdoor temperature is low, the volume of refrigerant circulating in thecompressor decreases due to the drop in refrigerantpressure and high compression (to protect fromoverheating), thereby reducing heating capacity. The Flash Injection Circuit injects refrigerant to maintain the refrigerant circulation volume and compressor operation load, therebymaintaining heating capacity.
Heat Interchanger (HIC) Injection Compressor
Purpose: To increase the volume of refrigerant being circulated
Effect: Improves heating capacity at low outdoortemperatures and enables higher indoor-air outlettemperature adjustment and higher defrostoperation speed
HIC cross-sectional view
Refrigerant passes through LEV C(refrigerant pressure lowered)
Refrigerant doesn’t pass through LEV C
The compressor is subjected to a heavy load whencompressing liquid refrigerant, the result being loweroperation efficiency. The addition of HIC supportsrefrigerant heat exchange at two different pressure levels.The heat-exchange process transforms the injected liquidrefrigerant into a gas liquid state, thereby decreasing theload on the compressor during the compression process.
Refrigerant passes from the HIC into the compressorthrough the injection port. Having two refrigerant inletsmakes it possible to raise the volume of refrigerant beingcirculated when the outdoor temperature is low and atthe start of heating operation.
Discharge port
Normal refrigerant flow
Refrigerant flow
Suction port
Injection port
Purpose: Transform liquid refrigerant into liquid-gas state
Effect: Injection circuit increases energy efficiency
A B
ZUBADAN Defrost Control and FasterRecovery from Defrost Operation
Page 71
Zubadan InverterThe ZUBADAN Series incorporates Flash Injection Technologythat improves the already high heating capacity of the system. This newestmember of the Mr Slim range ensures comfortable heat pump-driven heating performance in colder regions.
Page 70
Improved Heating PerformanceMitsubishi Electric’s unique “Flash Injection Circuit”achieves a remarkably high heating performance.
This technology has resulted in an excellent heatingcapacity rating in outdoor temperatures as low as -15°Cand the guaranteed heating operation range of theheating mode has been extended to -25°C. Accordingly,the Zubadan inverters are perfect for warming homes in the coldest of regions.
Mitsubishi Electric’s Flash Injection Technology
The Key to High Heating Performanceat Low Outdoor Temperatures
Enhanced ComfortThe Flash Injection Circuit improves start-up and recovery from defrost operation. A newly introduceddefrost operation control also improves defrost frequency. These features enable the temperature to reach the settemperature more quickly and contribute to maintainingit at the desired setting.
■Operation data for 25 Jan. 2005 ■Operation data for 2 Dec. 2004
8:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00
60°C
50°C
40°C
30°C
20°C
10°C
0°C
-10°C
20:0018:00
60°C
50°C
40°C
30°C
20°C
10°C
0°C
-10°C
-20°C
-30°C
22:00 0:00 2:00 4:00 6:00
Installationexample
LEV B
LEV C
LEVA
Heatinterchanger(HIC)
Refrigerant flow
A
B
IndoorHEX
Powerreceiver
OutdoorHEX
Injection compressor(injection port)
Flash Injection Circuit
Heat Interchanger (HIC)
Injection Compressor
A
B
Flash Injection Circuit
Field test results:Office building in Ashikawa, Hokkaido, Japan
Page 73
PLA-RP 4-Way Blow Cassette
Page 72
The PLA-RP-BA(2)(3) (PLFY-P-VBM-E for City Multi)4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.
Wide AirflowThe wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heatingoperation. A reduction in the air speed by 20% (compared to the previous product) eliminates the uncomfortable draftsensation often experienced.
Reduced Draft Air DistributionReduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.
Independent Vane ControlIf the airflow direction needs to be changed as a result of analtered room layout or due to the mode selected (i.e. cooling orheating), the air direction of each vane can be set independentlyusing the PAR-30MAA wired remote controller.
� Previous product � New product
Reduced Draft AirDistribution
PAR-30MAA
Down blow
Horizontal blow
Adjustable Fixed
Automatic Airflow Adjustment ModeThe automatic airflow adjustment mode is provided in additionto the 4 normal airflow stages and allows automatic adjustmentof the airflow in accordance with the difference between the settemperature and the room temperature.
For example: The automatic airflow adjustment mode allowsquick cooling of a room using high mode, then when the roomtemperature has stabilised, the low mode will be applied tomaximise comfort.
HighLow Automatic airflowadjustmentMedium 2Medium 1
Grille with Automatic FilterLowering Function (Optional)This grille can be operated by both the wired remote controllerand the exclusive infra-red remote controller. It can be loweredin 8 steps down to 4m in accordance with the ceiling height,enabling you to easily clean the air filter. Regular cleaning of thefilter is an important factor in saving energy.
PAR-30MAA Wired Remote Controller
Elevation Grille Remote Controller(comes with the grille)
Automaticlowering
to
4m
360°The "I-See Sensor" rotates to measure the floor temperature
The (optional corner panel) Provides EvenTemperature Distribution and Reduces Energy Consumption
The “I-See Sensor” uses temperature sensing technologydeveloped by Mitsubishi Electric. In order to create acomfortable environment in shops and offices, it is essentialto control the temperature near the floor where occupantsand visitors gather. The “I-See Sensor”measures the infra-redrays generated from the surrounding wall and floor surfacesand converts these into temperature values.
In addition, floor temperatures are also measured at distantspots, allowing optimum airflow to reach these areas.
� “I-See Sensor” operation: The “I-See Sensor”rotates slowly in intervals of 5 seconds, correctlymeasuring the temperature of the entire floor space.
5 seconds 5 seconds 5 seconds 5 seconds
In the past... only the inlet temperature near theceiling was measured, tending to overlook the uneventemperature distribution near the floor.
Conventional air conditioning in shops and offices only measuredthe temperature near to the ceiling, therefore the uneventemperature distribution between the ceiling and the floorremained unchecked.
As a result, the set temperature tended to be higher in orderto obtain comfort at floor level.
Inlet temperature sensor
Area measured by cassette model without "I-See Sensor"
37ºC
25ºC
13ºC
Without “I-See Sensor”.Set temperature is23ºC (in Heating)
e.g. To achieve a sensible temperature of 20ºC, the set temperature must be as high as 23ºC
Inlet temperature sensor
2.7m
Area measured by the cassette model equipped with "I-See Sensor"360°
sensing
37ºC
25ºC
13ºC
With the “I-See Sensor” plus automatic airflowadjustment mode.
Set temperature is 20ºC (in Heating)
e.g. With the set temperature at 20ºC, a sensible temperature of 20ºC at floor level can be obtained.
With “I-See Sensor”... both the floor temperature and inlet temperature are measured.
The 4-Way Blow Ceiling Cassette with the “I-See Sensor”simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increasedenergy savings.
Page 75Page 74
“SensibleTemperature Control”to Prevent Excessive Cooling and Heating
By measuring the inlet temperature and floortemperature, a temperature felt by
the human body (sensible temperature)will be calculated and maintained,
suppressing excessive cooling and heating.
PLA-RP 4-Way Blow Cassette
Page 77
PKA-RP Power Inverter Heat Pump, Wall Mounted System
PKA-RP Standard Inverter Heat Pump, Wall Mounted System
PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System
PKA-RP Power Inverter Heat Pump, High SHF Wall Mounted System
SEZ-KD-VAQ Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System
PEA-RP-GAQ Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
PEA-RP-GAQ Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
SLZ-KA-VAQ Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System
PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PLA-RP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PCA-RP Power Inverter Heat Pump, Ceiling Suspended System
PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System
PCA-RP-HAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System
PCA-RP-HAQ Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System
PSA-RP Power Inverter Heat Pump, Floor Standing System
PSA-RP Standard Inverter Heat Pump, Floor Standing System
PHV DXE Heat Pump, Air Curtain
PHV NT Chilled Water Heat Pump, Sensible Cooling Wall Mounted System
Mr Slim Multi-Split Systems Heat Pump
Outdoor Units
Air Handling Unit Controller
Mr Slim Accessories / Optional Extras
82
80
78
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
130
131
Page 76
Designed tofit anywhere
The Adaptable Mr Slim Range
Simple technologyat its best
Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
For further information please go to www.eca.gov.uk
Contents
Available in a variety of options, the Mr Slim range fits in wherever it’sneeded. Indoor units can be fourway blow cassettes, ducted,floor, wall or ceiling mounted.
Up to four indoor units can then be connected to a single outdoor unitproviding the ideal air conditioningsolution.
INDOOR UNIT PKA-RP35-50HAL
INDOOR UNIT PKA-RP60-100KAL
Mr
SlimRange
Front View > Side View >
249 5155688
898
55
295
Front View > Side View >
5295
1170
365
74 (855) 241
PK
A-R
PPower Inverter Heat Pump
Dimensions
Page 79
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) – HRC (A)
INTERCONNECTING CABLE No. CORES
PKA-RP35HAL
4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4)
3.3 (1.45-4.15)
0.81
3.63 / 3.67
A / A
9-10.5-12
12.7 (1/2”)
6.35 (1/4”)
36-40-43
898
249
295
13
Fed by Outdoor Unit
Single
6
4
PKA-RP50HAL
5.0 (2.5-7.3)
4.6 (2.3-5.6)
4.25 (2.15-6.2)
4.25 (2.1-5.15)
0.72
3.62 / 3.22
A / A
9-10.5-12
12.7 (1/2”)
6.35 (1/4”)
36-40-43
898
249
295
13
Fed by Outdoor Unit
Single
6
4
PKA-RP60KAL
7.0 (2.8-8.2)
6.0 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.86
3.98 / 3.90
A / A
18-20-22
15.88 (5/8”)
9.52 (3/8”)
39-42-45
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PKA-RP71KAL
8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.78
3.76 / 3.62
A / A
18-20-22
15.88 (5/8”)
9.52 (3/8”)
39-42-45
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PKA-RP100KAL
11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.73
3.61 / 3.45
A / A
20-23-26
15.88 (5/8”)
9.52 (3/8”)
41-45-49
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
PUHZ-RP35VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.13 / 0.98
1.01 / 0.83
5
5.33 / 4.66 [13.4]
-
16
3
50
30
2.5
PUHZ-RP50VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.38 / 1.43
1.23 / 1.22
5
6.45 / 6.68 [13.4]
-
16
3
50
30
2.5
PUHZ-RP60VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.76 / 1.54
1.57 / 1.31
5
8.09 / 7.11 [19.4]
-
20
3
50
30
3.5
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
2.13 / 1.96
1.90 / 1.67
5
9.75 / 8.99 [19.4]
-
20
3
50
30
3.5
PUHZ-RP100VKA/YKA
51 / 49 (46)
116 / 124
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
3.10 / 2.90
2.76 / 2.47
5
14.15 / 13.25 [27.1]
5.32 / 5.01 [8.6]
32 / 10
3 / 5
75
30
5.0
Wall Mounted System� Flat panel, compact indoor unit design
� Adjustable louvres for uniform air distribution
� Internal pipe connection to wall mountedunit for easy and neat installation
PKA-RP Power Inverter Heat Pump
Technical Information
Page 78
INDOOR UNIT PKA-RP100KAL
Mr
SlimRange
PK
A-R
PStandard Inverter Heat Pump
Dimensions
Page 81
Front View > Side View >
5295
1170
365
74 (855) 241
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PKA-RP100KAL
11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.75
3.21 / 3.01
C / B
20-23-26
15.88 (5/8”)
9.52 (3/8”)
41-45-49
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PUHZ-P - OUTDOOR UNITS
PUHZ-P100VHA3/YHA
54 / 50 (47)
75 / 77
950
330 + 30
943
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.49 / 3.12
3.11 / 2.65
8 / 3
14.81 / 14.15 [28.6]
5.65 / 5.06 [13.6]
32 / 16
3 / 5
50
30
3.0
Wall Mounted System
� Flat panel, compact indoor unit design
� Adjustable louvres for uniform air distribution
� Internal pipe connection to wall mounted unit for easy and neat installation
� 3-phase Standard Inverters now available
PKA-RP Standard Inverter Heat Pump
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
Technical Information
Page 80
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 20m
INDOOR UNIT PKA-RP100KAL
Mr
SlimRange
PK
A-R
PZubadan Inverter Heat Pump
Dimensions
Page 83
Front View > Side View >
5295
1170
365
74 (855) 241
Wall Mounted System
PKA-RP Zubadan Inver ter Heat Pump
Technical Information
� Flat panel, compact indoor unit design
� Stable Heating Performance - Full heating capacity at -15°C,a 30% capacity improvement over the next size up Power Inverter
� Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can providecontinuous heating for up to 150 mins
� Quick Start-Up - At -20ºC, full heating capacity is achievedin about 20 mins, improving comfort levels
Zubadan sets a new standard in performance
The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) – HRC (A)
INTERCONNECTING CABLE No. CORES
PKA-RP100KAL
11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.73
3.61 / 3.41
A / A
20-23-26
15.88 (5/8”)
9.52 (3/8”)
41-45-49
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PUHZ-HRP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
PUHZ-HRP100VHA2/YHA2
52 / 51 (48)
120 / 134
950
330 + 30
1350
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.10 / 2.93
4.50 / 2.49
14 / 3
14.15 / 13.39 [35.6]
5.32 / 5.06 [13.6]
40 / 16
3 / 5
75
30
5.5
Page 82
INDOOR UNIT PKA-RP100KAL
Mr
SlimRange
Front View > Side View >
5295
1170
365
74 (855) 241
PK
A-R
PPower Inverter Heat Pump (High SHF)
Dimensions
Page 85
High SHF Wall Mounted System
� High SHF system for use in server rooms and laboratories
� Flat panel, compact indoor unit design
� Adjustable louvres for uniform air distribution
� Internal pipe connection to wall mountedunit for easy and neat installation
� Duty Standby Operation available using multipleoutdoor units (via PAR-30MAA)
� Able to connect to Run Standby Panel PANEL _RS_SMS (via Procon A1M).A maximum of 8 indoor units can be connected in this way, see page 306for further information
� Gravity drain to rear of indoor unit for safe installation and operation
PKA-RP Power Inverter Heat Pump
Technical Information
Page 84
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Cooling
SHF (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
SHF (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
EER (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
EER (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
ENERGy LABEL Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PKA-RP100KAL
6.0
0.94
0.96
4.29
3.75
A
20-23-26
15.88 (5/8”)
9.52 (3/8”)
41-45-49
1170
295
365
21
Fed by Outdoor Unit
Single
6
4
PUHZ-RP - OUTDOOR UNITS
PUHZ-RP60VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.4
1.6
5
19.6
20
3
50
30
3.5
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW)
Cooling (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
Cooling (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
STARTING CURRENT (A)
MAX SySTEM RUNNING CURRENT (A)
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 20m
This new connection provides a low cost split system solution tohigh sensible applications such as server rooms and laboratories.
Upper View >
INDOOR UNIT SEZ-KD25-71VAQ
Front View >
Mr
SlimRange
SEZ
-KD
-VA
Q Inverter Heat Pump
Dimensions
Models A B C D E F
Size 25 700 752 798 660 7 600
Size 35-50 900 952 998 860 9 800
Size 60-71 1100 1152 1198 1060 11 1000
Page 87
Side View >
SEZ-KD-VAQ - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) (15Pa) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
SUZ-KA-VA2 - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
SEZ-KD25VAQ
3.0 (0.9-4.5)
2.5 (0.9-3.2)
2.5 (0.75-3.75)
2.5 (0.9-3.15)
0.80
3.61 / 3.33
A / A
6.0-7.0-9.0
5-15-35-50
9.52 (3/8”)
6.35 (1/4”)
23-26-30
790
700
200
18
Fed by Outdoor Unit
Single
6
4
SEZ-KD35VAQ
4.2 (0.9-5.0)
3.7 (1.0-3.9)
3.5 (0.75-4.15)
3.65 (1.0-3.85)
0.78
3.72 / 3.39
A / A
7-9-11
5-15-35-50
9.52 (3/8”)
6.35 (1/4”)
23-28-33
990
700
200
21
Fed by Outdoor Unit
Single
6
4
SEZ-KD50VAQ
6.4 (1.1-7.2)
5.1 (1.1-5.6)
5.3 (0.9-6.0)
5.05 (1.1-5.55)
0.76
3.54 / 3.11
B / B
10-12.5-15
5-15-35-50
12.7 (1/2”)
6.35 (1/4”)
30-34-37
990
700
200
23
Fed by Outdoor Unit
Single
6
4
SEZ-KD60VAQ
7.4 (0.9-8.0)
5.6 (1.1-6.3)
6.15 (0.75-6.65)
5.55 (1.1-6.25)
0.79
3.51 / 3.01
B / B
12-15-18
5-15-35-50
15.88 (5/8”)
6.35 (1/4”)
30-34-38
1190
700
200
27
Fed by Outdoor Unit
Single
6
4
SEZ-KD71VAQ
8.1 (0.9-10.4)
7.1 (0.9-8.3)
6.75 (0.75-8.65)
7.05 (0.9-8.25)
0.74
3.72 / 3.01
A / B
12-16-20
5-15-35-50
15.88 (5/8”)
9.52 (3/8”)
30-35-40
1190
700
200
27
Fed by Outdoor Unit
Single
6
4
SUZ-KA25VA2
46 / 46
33
800
285
550
220-240v, 50Hz
Single
0.83 / 0.75
0.76 / 0.60
3.65
4.05 / 3.45 [8.6]
10
3
20
12
0.8
SUZ-KA35VA2
48 / 47
37
800
285
550
220-240v, 50Hz
Single
1.13 / 1.09
1.03 / 0.87
4.75
5.25 / 5.05 [9.7]
10
3
20
12
1.05
SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.81 / 1.64
1.65 / 1.31
6.75
7.05 / 7.45 [16.7]
20
3
30
30
1.6
SUZ-KA60VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
2.11 / 1.86
1.92 / 1.49
9.75
10.45 / 9.05 [16.7]
20
3
30
30
1.8
SUZ-KA71VA2
55 / 55
53
840
330
880
220-240v, 50Hz
Single
2.18 / 2.36
1.98 / 1.89
8.89
9.85 / 9.75 [17.0]
20
3
30
30
1.8
Ceiling Concealed Ducted System
SEZ-KD-VAQ Inverter Heat Pump
Designed for homes, offices, restaurants or shops,the SEZ-KD-VAQ series operates at low noise levels.Its new improved low unit height and lightweightdesign also help to make installation easierand more convenient.
Technical Information
Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.
Page 86
INDOOR UNIT PEAD-RP35-140JAQ
Mr
SlimRange
PEA
D-R
PPower Inverter Heat Pump
Dimensions
Page 89
Side View >
Upper View >
Front View >
Air
outletA
irinlet
40
1558
57
10
100
100x(E-1)=F
A
B(Suspension bolt pitch)
C
23
30
57 20 D (Duct)
D
643(Suspension bolt pitch)
Drain pump
Drain pipe(Spontaneous draining)
Drain pipe(O.D. 32)
250
122
33
40
23 10238
32 700
732
136 67
356
100
41
217
178(
Duc
t)
Rear View >
A BPEAD-RP35-50JAQ
PEAD-RP60-71JAQ
900 954
PEAD-RP100-125JAQ
1100 1154
C1000
1200
D860
1060
E9
11
PEAD-RP140JAQ
1400 1454 1500 1360 14
F800
1000
G858
1058
1300 1358
1600 1654 1700 1560 16 1500 1558
Model
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
NOISE (dBA) (50Pa) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PEAD-RP140JAQ
16.0 (5.7-18.0)
14.0 (6.2-15.3)
13.6 (4.85-15.3)
12.9 (5.7-14.1)
0.83
3.96 / 3.21
A / A
32-39-46
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
34-38-43
1600
732
250
47
Fed by Outdoor Unit
Single
6
4
PEAD-RP125JAQ
14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.84
4.00 / 3.24
A / A
29.5-33.5-42
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
33-36-40
1400
732
250
43
Fed by Outdoor Unit
Single
6
4
PEAD-RP100JAQ
11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.82
4.12 / 3.61
A / A
24-29-34
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
29-34-38
1400
732
250
41
Fed by Outdoor Unit
Single
6
4
PEAD-RP71JAQ
8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.83
4.00 / 3.50
A / A
17.5-21-25
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
26-30-34
1100
732
250
33
Fed by Outdoor Unit
Single
6
4
PEAD-RP60JAQ
7.0 (2.8-8.2)
6.0 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.83
4.00 / 3.75
A / A
14.5-18-21
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
25-29-33
1100
732
250
33
Fed by Outdoor Unit
Single
6
4
PEAD-RP50JAQ
6.0 (2.5-7.3)
5.0 (2.3-5.6)
5.1 (2.15-6.2)
4.6 (2.1-5.15)
0.84
3.85 / 3.23
A / A
12-14.5-17
12.7 (1/2”)
6.35 (1/4”)
35-50-70-100-150
26-31-35
900
732
250
28
Fed by Outdoor Unit
Single
6
4
PEAD-RP35JAQ
4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4)
3.3 (1.45-4.15)
0.85
3.73 / 3.53
A / A
10-12-14
12.7 (1/2”)
6.35 (1/4”)
35-50-70-100-150
23-27-30
900
732
250
26
Fed by Outdoor Unit
Single
6
4
PUHZ-RP35VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.10 / 1.02
0.98 / 0.87
5
5.15 / 4.81 [14.1]
-
16
3
50
30
2.5
PUHZ-RP50VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.56 / 1.55
1.39 / 1.32
5
7.38 / 7.35 [14.4]
-
16
3
50
30
2.5
PUHZ-RP60VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.75 / 1.60
1.56 / 1.36
5
8.29 / 7.63 [20.6]
-
25
3
50
30
3.5
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
2.00 / 2.03
1.78 / 1.73
5
9.46 / 9.62 [21]
-
25
3
50
30
3.5
PUHZ-RP100VKA/YKA
51 / 49 (46)
116 / 124
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
2.72 / 2.77
2.42 / 2.35
5
12.73 / 12.98 [29.2]
5.48 / 5.63 [10.7]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP125VKA/YKA
52 / 50 (47)
116 / 126
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
3.50 / 3.86
3.12 / 3.28
5
16.45 / 18.09 [29.3]
7.25 / 7.89 [12.3]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP140VKA/YKA
52 / 50 (47)
118 / 132
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
4.04 / 4.36
3.60 / 3.71
5
18.94 / 20.39 [30.8]
8.25 / 8.83 [13.8]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
Ceiling Concealed Ducted System
PEAD-RP Power Inverter Heat Pump
Technical Information
Page 88
� Reduced height - entire range now only 250mm
� Wider range of external staticpressure settings across entire range
� Reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dBA
� Drain pump included as standard
Mr
SlimRange
PEA
D-R
PStandard Inverter Heat Pump
INDOOR UNIT PEAD-RP35-140JAQ
Dimensions
Page 91
Side View >
Upper View >
Front View >
Air
outletA
irinlet
40
1558
57
10
100
100x(E-1)=F
A
B(Suspension bolt pitch)
C
23
30
57 20 D (Duct)
D
643(Suspension bolt pitch)
Drain pump
Drain pipe(Spontaneous draining)
Drain pipe(O.D. 32)
250
122
33
40
23 10238
32 700
732
136 67
356
100
41
217
178(
Duc
t)
Rear View >
A BPEAD-RP35-50JAQ
PEAD-RP60-71JAQ
900 954
PEAD-RP100-125JAQ
1100 1154
C1000
1200
D860
1060
E9
11
PEAD-RP140JAQ
1400 1454 1500 1360 14
F800
1000
G858
1058
1300 1358
1600 1654 1700 1560 16 1500 1558
Model
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
NOISE (dBA) (50Pa) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PEAD-RP140JAQ
16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.84
3.61 / 3.01
A / B
32-39-46
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
34-38-43
1600
732
250
47
Fed by Outdoor Unit
Single
6
4
PEAD-RP125JAQ
14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.85
3.62 / 2.91
A / C
29.5-35.5-42
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
33-36-40
1400
732
250
43
Fed by Outdoor Unit
Single
6
4
PEAD-RP100JAQ
11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.85
3.61 / 3.09
A / B
24-29-34
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
29-34-38
1400
732
250
41
Fed by Outdoor Unit
Single
6
4
PEAD-RP71JAQ
8.0 (0.9-10.2)
7.1 (0.9-8.1)
6.65 (0.75-8.5)
7.05 (0.9-8.05)
0.83
3.92 / 3.38
A / A
17.5-21-25
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
26-30-34
1100
732
250
33
Fed by Outdoor Unit
Single
6
4
PEAD-RP60JAQ
7.0 (0.9-8.0)
5.7 (1.1-6.3)
5.8 (0.75-6.65)
5.65 (1.1-6.25)
0.86
3.61 / 3.39
A / A
14.5-18-21
15.88 (5/8”)
6.35 (1/4”)
35-50-70-100-150
25-29-33
1100
732
250
33
Fed by Outdoor Unit
Single
6
4
PEAD-RP50JAQ
5.9 (0.9-7.2)
4.9 (1.1-5.6)
4.9 (0.75-6.0)
4.85 (1.1-5.55)
0.85
3.64 / 3.22
A / A
12-14.5-17
12.7 (1/2”)
6.35 (1/4”)
35-50-70-100-150
26-31-35
900
732
250
28
Fed by Outdoor Unit
Single
6
4
PEAD-RP35JAQ
4.1 (0.9-5.0)
3.6 (1.0-3.9)
3.4 (0.75-4.15)
3.55 (1.0-3.85)
0.85
3.69 / 3.40
A / A
10-12-14
9.52 (3/8”)
6.35 (1/4”)
35-50-70-100-150
23-27-30
900
732
250
26
Fed by Outdoor Unit
Single
6
4
SUZ-KA35VA2
48 / 47
37
800
285
550
220-240v, 50Hz
Single
1.11 / 1.06
1.01 / 0.85
4.75
5.82 / 5.62 [10.3]
-
16
3
20
12
1.05
SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.62 / 1.52
1.47 / 1.22
6.75
7.74 / 8.14 [17.4]
-
20
3
30
30
1.6
SUZ-KA60VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.94 / 1.68
1.77 / 1.34
9.75
11.37 / 9.97 [17.6]
-
20
3
30
30
1.8
SUZ-KA71VA2
55 / 55
53
840
330
880
220-240v, 50Hz
Single
2.04 / 2.10
1.86 / 1.68
8.89
10.92 / 10.82 [18.1]
-
20
3
30
30
1.8
PUHZ-P100VHA3/YHA
54 / 50 (47)
75 / 77
950
330 + 30
943
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.10 / 3.04
2.76 / 2.58
8 / 3
16.18 / 15.38 [30.7]
5.12 / 5.03 [15.7]
32 / 16
3 / 5
50
30
3.0
PUHZ-P125VHA3/YHA
55 / 51 (48)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.87 / 4.22
3.44 / 3.59
11 / 4
19.49 / 20.59 [30.8]
6.29 / 6.85 [15.8]
32 / 16
3 / 5
50
30
4.5
PUHZ-P140VHA3/YHA
56 / 52 (49)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
4.43 / 4.52
3.94 / 3.84
11 / 4
23.23 / 24.38 [32.3]
7.19 / 7.34 [15.8]
40 / 16
3 / 5
50
30
4.5
SUZ-KA / PUHZ-P - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg)
Ceiling Concealed Ducted System
PEAD-RP Standard Inverter Heat Pump
The Standard Inverter range provides inverter solutions for customerswho want all the benefits that inverters offer, but do not have the budgetavailable for the Power Inverter range.
Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.
Technical Information
Page 90
� Reduced height - entire range now only 250mm
� Wider range of external static pressure settingsacross entire range
� Reduced noise levels thanks to the use of a newlydesigned centrifugal fan - as low as 23dBA
� Drain pump included as standard
� 3-phase Standard Inverters now available
Mr
SlimRange
PEA
D-R
P Zubadan Inverter Heat Pump
INDOOR UNIT PEAD-RP71-125JAQ
Dimensions
Page 93
A BPEAD-RP71JAQ
PEAD-RP100-125JAQ
1100 1154
C
1200
D
1060
E
11
1400 1454 1500 1360 14
F
1000
G
1058
1300 1358
Model
Side View >
Upper View >
Front View >
Air
outletA
irinlet
40
1558
57
10
100
100x(E-1)=F
A
B(Suspension bolt pitch)
C
23
30
57 20 D (Duct)
D
643(Suspension bolt pitch)
Drain pump
Drain pipe(Spontaneous draining)
Drain pipe(O.D. 32)
250
122
33
40
23 10238
32 700
732
136 67
356
100
41
217
178(
Duc
t)
Rear View >
� Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter
� Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins
� Quick Start-Up - At -20ºC, full heating capacity is achievedin about 20 mins, improving comfort levels
Ceiling Concealed Ducted System
PEAD-RP Zubadan Inverter Heat Pump
Technical Information
Page 92
Zubadan sets a new standard in performance
The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
NOISE (dBA) (50Pa) Lo-Mi-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PEAD-RP125JAQ
14.0 (5.0-16.0)
12.5 (5.5-14.0)
13.85 (4.95-15.85)
11.5 (5.05-12.9)
0.84
3.61 / 3.21
A / A
29.5-33.5-42
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
33-36-40
1400
732
250
43
Fed by Outdoor Unit
Single
6
4
PEAD-RP100JAQ
11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.82
3.61 / 3.27
A / A
24-29-34
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
29-34-38
1400
732
250
41
Fed by Outdoor Unit
Single
6
4
PEAD-RP71JAQ
8.0 (3.5-10.2)
7.1 (3.3-8.1)
7.9 (3.45-10.1)
6.55 (3.05-7.45)
0.83
3.42 / 3.30
B / A
17.5-21-25
15.88 (5/8”)
9.52 (3/8”)
35-50-70-100-150
26-30-34
1100
732
250
33
Fed by Outdoor Unit
Single
6
4
PUHZ-HRP71VHA2
52 / 51 (48)
120
950
330 + 30
1350
220-240v, 50Hz
Single
2.34 / 2.15
3.39 / 1.83
14
10.99 / 10.15 [31.5]
-
32
3
75
30
5.5
PUHZ-HRP100VHA2/YHA2
52 / 51 (48)
120 / 134
950
330 + 30
1350
220-240v, 50Hz / 380-415,50Hz
Single / 3
3.10 / 3.06
4.50 / 2.60
14 / 3
14.43 / 14.28 [37.7]
6.07 / 6.09 [15.7]
40 / 16
3 / 5
75
30
5.5
PUHZ-HRP125YHA2
52 / 51 (48)
134
950
330 + 30
1350
380-415,50Hz
3
3.88 / 3.89
5.63 / 3.31
3
-
7.84 / 7.94 [15.8]
16
5
75
30
5.5
PUHZ-HRP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
INDOOR UNIT PEA-RP200GAQ
Upper View >
Front View >
Side View >
INDOOR UNIT PEA-RP250GAQ
INDOOR UNIT PEA-RP400-500GAQ
Upper View >
Front View >
Side View >
Upper View >
Front View >
Side View >
Mr
SlimRange
PEA
-RP-G
AQPower Inverter Heat Pump
Dimensions
Page 95
PEA-RP-GAQ - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
POWER INPUT (kW) (nominal)
(UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [Max]
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. Cores
INTERCONNECTING CABLE No. CORES
PUHZ-RP-YKA - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [Max] Heating/Cooling
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
PEA-RP200GAQ
22.4 (9.5-25.0)
19.0 (9.0-22.4)
19.05 (8.1-21.25)
17.5 (8.3-20.6)
0.81
3.45 / 2.84
B / C
52-65
28.58 (1 1/8”)
9.52 (3/8”)
150
48-51
1400
634
400
70
380-415v, 50Hz
3
1.00
0.89
5.6
2.0 [2.4]
6
5
3
PEA-RP250GAQ
27.0 (12.5-31.5)
22.0 (11.2-28.0)
22.95 (10.65-26.8)
20.25 (10.3-25.75)
0.86
3.29 / 2.64
C / D
64-80
28.58 (1 1/8”)
12.7 (1/2”)
150
49-52
1600
634
400
77
380-415v, 50Hz
3
1.18
1.05
5.6
2.3 [2.8]
6
5
3
PUHZ-RP200YKA
59 / 58 (55)
135
1050
330 + 30
1338
380-415v, 50Hz
3
6.5 / 6.7
5.79 / 5.7
5
8.63 / 8.94 [19]
20
5
120
30
7.1
PUHZ-RP250YKA
59 / 58 (55)
141
1050
330 + 30
1338
380-415v, 50Hz
3
8.2 / 8.34
7.3 / 7.09
5
11.01 / 11.23 [21]
25
5
120
30
7.7
PEA-RP400GAQ
44.8 (18.0-50.0)
38.0 (18.0-44.8)
38.1 (15.3-42.5)
34.95 (16.55-41.2)
0.75
3.57 / 2.93
B / C
120
28.58 (1 1/8”) x2
9.52 (3/8”) x2
150
52
1947
764
595
130
380-415v, 50Hz
3
1.55
1.38
8.7
3.8 [4.6]
10
5
3
PEA-RP500GAQ
54.0 (25.0-63.0)
44.0 (22.4-56.0)
45.9 (21.25-53.55)
40.5 (20.6-51.5)
0.77
3.20 / 2.56
D / E
160
28.58 (1 1/8”) x2
12.7 (1/2”) x2
150
53
1947
764
595
133
380-415v, 50Hz
3
2.84
2.53
10
5.4 [6.5]
10
5
3
PUHZ-RP200YKA x2
59 / 58 (55)
135
1050
330 + 30
1338
380-415v, 50Hz
3
12.55 / 12.95
11.17 / 11.01
5
8.63 / 8.94 [19]
20
5
120
30
7.1
PUHZ-RP250YKA x2
59 / 58 (55)
141
1050
330 + 30
1338
380-415v, 50Hz
3
16.88 / 17.16
15.02 / 14.59
5
11.01 / 11.23 [21]
25
5
120
30
7.7
Large Capacity Ceiling Concealed Ducted System
PEA-RP-GAQ Power Inverter Heat Pump
� Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units
� Static pressure of up to 150Pa
Technical Information
Page 94
INDOOR UNIT PEA-RP200GAQ
Upper View >
Front View >
Side View >
INDOOR UNIT PEA-RP250GAQ
INDOOR UNIT PEA-RP400-500GAQ
Upper View >
Front View >
Side View >
Upper View >
Front View >
Side View >
Mr
SlimRange
PEA
-RP-G
AQStandard Inverter Heat Pump
Dimensions
Page 97
PEA-RP-GAQ - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
POWER INPUT (kW) (nominal)
(UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [Max]
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. Cores
INTERCONNECTING CABLE No. CORES
PEA-RP200GAQ
22.4 (9.5-25.0)
19.0 (9.0-22.4)
19.05 (8.1-21.25)
17.5 (8.3-20.6)
0.81
3.04 / 2.64
D / D
52-65
28.58 (1 1/8”)
9.52 (3/8”)
150
48-51
1400
634
400
70
380-415v, 50Hz
3
1.00
0.89
5.6
2.0 [2.4]
6
5
3
PEA-RP250GAQ
27.0 (12.5-31.5)
22.0 (11.2-28.0)
22.95 (10.65-26.8)
20.25 (10.3-25.75)
0.86
3.19 / 2.61
D / D
64-80
28.58 (1 1/8”)
12.7 (1/2”)
150
49-52
1600
634
400
77
380-415v, 50Hz
3
1.18
1.05
5.6
2.3 [2.8]
6
5
3
PUHZ-P200YHA3
59 / 59 (56)
126
950
330+30
1350
380-415v, 50Hz
3
7.36 / 7.21
6.55 / 6.13
5
9.88 / 9.47 [19]
20
5
70
30
5.8
PUHZ-P250YHA3
59 / 59 (56)
135
950
330+30
1350
380-415v, 50Hz
3
8.47 / 8.44
7.54 / 7.17
5
12.0 / 11.0 [21]
25
5
70
30
7.1
PEA-RP400GAQ
44.8 (19.0-50.0)
38.0 (18.0-44.8)
38.1 (16.15-42.5)
34.95 (16.55-41.2)
0.75
3.14 / 2.72
D / D
120
28.58 (1 1/8”) x2
9.52 (3/8”) x2
150
52
1947
764
595
130
380-415v, 50Hz
3
1.55
1.38
8.7
3.8 [4.6]
10
5
3
PEA-RP500GAQ
54.0 (25.0-63.0)
44.0 (22.4-56.0)
45.9 (21.25-53.55)
40.5 (20.6-51.5)
0.77
3.10 / 2.53
D / E
160
28.58 (1 1/8”) x2
12.7 (1/2”) x2
150
53
1947
764
595
133
380-415v, 50Hz
3
2.84
2.53
10
5.4 [ 6.5]
10
5
3
PUHZ-P200YHA3 x2
59 / 59 (56)
126
950
330+30
1350
380-415v, 50Hz
3
14.27 / 13.97
12.7 / 11.88
5
9.88 / 9.47 [19]
20
5
70 per outdoor
30
5.8
PUHZ-P250YHA3 x2
59 / 59 (56)
135
950
330+30
1350
380-415v, 50Hz
3
17.42 / 17.36
15.5 / 14.76
5
12.0 / 11.0 [21]
25
5
70 per outdoor
30
7.1
PUHZ-P-YHA3 - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [Max] Heating/Cooling
FUSE RATING (BS88) – HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
Large Capacity Ceiling Concealed Ducted System
PEA-RP-GAQ Standard Inverter Heat Pump
� Twin, triple or quadruple configurations on oneoutdoor unit, utilising Mr Slim indoor units
� Static pressure of up to 150Pa
Technical Information
Page 96
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
Lower View >
INDOOR UNIT SLZ-KA25-50VAQ
Side View >
Mr
SlimRange
SLZ
-KA
-VA
Q Inverter Heat Pump
Dimensions
Page 99
600x600 4-Way Blow Ceiling Cassette System
SLZ-KA-VAQ - INDOOR UNITS
SLZ-KA-VAQ Inverter Heat Pump
The SLZ-KA-VAQ series is perfect for both residential andsmall business applications, as it offers inverter technologyalongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of208mm, this lightweight unit makes installation a breeze.This unit also comes complete with a long life filter that will last for approximately 2,500 hours.
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi-Hi
DIMENSIONS (mm) (grille) Width
Depth
Height
WEIGHT (kg) Unit
Grille
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
GRILLE REFERENCE
SUZ-KA-VA2 - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m
SLZ-KA25VAQ
3.2 (0.9-4.5)
2.5 (0.9-3.2)
2.65 (0.75-3.75)
2.5 (0.9-3.15)
0.86
3.76 / 3.68
A / A
8-9-10
9.52 (3/8”)
6.35 (1/4”)
28-31-37
570 (650)
570 (650)
235 (20)
17
3
Fed by Outdoor Unit
Single
6
4
SLP-2AAW
SLZ-KA35VAQ
4.0 (0.9-5.0)
3.5 (1.0-3.9)
3.3 (0.75-4.15)
3.45 (1.0-3.85)
0.77
3.67 / 3.37
A / A
8-9-11
9.52 (3/8”)
6.35 (1/4”)
29-33-38
570 (650)
570 (650)
235 (20)
17
3
Fed by Outdoor Unit
Single
6
4
SLP-2AAW
SLZ-KA50VAQ
5.0 (0.9-6.5)
4.6 (1.1-5.2)
4.15 (0.75-5.4)
4.55 (1.1-5.15)
0.68
3.23 / 3.01
C / B
8-9-11
12.7 (1/2”)
6.35 (1/4”)
30-34-39
570 (650)
570 (650)
235 (20)
17
3
Fed by Outdoor Unit
Single
6
4
SLP-2AAW
SUZ-KA25VA2
46 / 46
33
800
285
550
220-240v, 50Hz
Single
0.85 / 0.68
0.77 / 0.54
3.65
4.05 / 3.45 [8.5]
10
3
20
12
0.8
SUZ-KA35VA2
48 / 47
37
800
285
550
220-240v, 50Hz
Single
1.09 / 1.04
0.99 / 0.83
4.75
5.15 / 4.95 [9.6]
10
3
20
12
1.05
SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.55 / 1.53
1.41 / 1.22
6.75
7.05 / 7.45 [16.7]
20
3
30
30
1.6
Technical InformationNote: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.
Page 98
INDOOR UNIT PLA-RP35-140BA(2)(3)
Models A B
Size 35-71 241 258
Size 100-140 281 298
Upper View >
Lower View >
Side View >
Mr
SlimRange
PLA
-RPPower Inverter Heat Pump
Dimensions
Page 101
� Airflow controllable for ceiling heights up to4.2m, with automatic adjustment of fan speed
� Reduced draft air distribution, withindependent vane control
� Filter lowering operation down to 4m(optional PLP-6BAJ grille required)
� Optional ‘I See Sensor' for energy saving andsmooth temperature control throughout the room
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi1-Mi2-Hi
DIMENSIONS (mm) Width
(Grille) Depth
Height
WEIGHT (kg) Unit
Panel
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
GRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE
PLA-RP140BA2
16.0 (5.7-18.0)
14.0 (6.2-15.3)
13.6 (4.85-15.3)
12.9 (5.7-14.1)
0.71
3.70 / 3.21
A / A
24-26-29-32
15.88 (5/8”)
9.52 (3/8”)
36-39-42-44
840 (950)
840 (950)
298 (35)
27
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP125BA2
14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.71
4.00 / 3.41
A / A
22-25-28-31
15.88 (5/8”)
9.52 (3/8”)
34-36-39-41
840 (950)
840 (950)
298 (35)
27
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP100BA3
11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.74
4.61 / 4.18
A / A
20-23-26-30
15.88 (5/8”)
9.52 (3/8”)
32-34-37-40
840 (950)
840 (950)
298 (35)
26
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP71BA2
8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.73
4.21 / 3.74
A / A
14-16-18-21
15.88 (5/8”)
9.52 (3/8”)
28-30-32-34
840 (950)
840 (950)
258 (35)
23
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP60BA
7.0 (2.8-8.2)
6.0 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.76
3.85 / 3.75
A / A
12-14-16-18
15.88 (5/8”)
9.52 (3/8”)
28-29-31-32
840 (950)
840 (950)
258 (35)
23
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP50BA
6.0 (2.5-7.3)
5.0 (2.3-5.6)
5.1 (2.15-6.2)
4.6 (2.1-5.15)
0.81
3.61 / 3.23
A / A
12-14-16-18
12.7 (1/2”)
6.35 (1/4”)
28-29-31-32
840 (950)
840 (950)
258 (35)
22
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP35BA
4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4)
3.3 (1.45-4.15)
0.84
3.66 / 3.36
A / A
11-12-13-15
12.7 (1/2”)
6.35 (1/4”)
27-28-29-31
840 (950)
840 (950)
258 (35)
22
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PUHZ-RP35VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.12 / 1.07
1.00 / 0.91
5
5.15 / 4.98 [13.2]
-
16
3
50
30
2.5
PUHZ-RP50VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.66 / 1.55
1.48 / 1.32
5
7.62 / 7.08 [13.4]
-
16
3
50
30
2.5
PUHZ-RP60VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.82 / 1.60
1.62 / 1.36
5
8.34 / 7.31 [19.4]
-
20
3
50
30
3.5
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.90 / 1.90
1.69 / 1.62
5
8.76 / 8.71 [19.5]
-
20
3
50
30
3.5
PUHZ-RP100VKA/YKA
51 / 49 (46)
116 / 124
1050
330 + 30
1338
220-240v, 50Hz /380-415v,50Hz
Single / 3
2.43 / 2.39
2.16 / 2.03
5
11.26 / 11.04 [27.5]
4.59 / 4.51 [9]
32 / 10
3 / 5
75
30
5.0
PUHZ-RP125VKA/YKA
52 / 50 (47)
116 / 126
1050
330 + 30
1338
220-240v, 50Hz/380-415v,50Hz
Single / 3
3.50 / 3.67
3.12 / 3.12
5
16.02 / 16.73 [27.5]
6.26 / 6.51 [10.5]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP140VKA/YKA
52 / 50 (47)
118 / 132
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
4.32 / 4.36
3.84 / 3.71
5
19.76 / 19.90 [29.1]
7.61 / 7.66 [12.1]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
4-Way Blow Ceiling Cassette System
PLA-RP Power Inverter Heat Pump
Technical Information
Page 100
INDOOR UNIT PLA-RP35-140BA(2)
Models A B
Size 35-71 241 258
Size 100-140 281 298
Upper View >
Lower View >
Side View >
Mr
SlimRange
PLA
-RPStandard Inverter Heat Pump
Dimensions
Page 103
SUZ-KA35VA2
48 / 47
37
800
285
550
220-240v, 50Hz
Single
1.04 / 1.09
0.95 / 0.87
4.75
4.97 / 4.77 [9.4]
-
10
3
20
12
1.05
SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.64 / 1.71
1.49 / 1.37
6.75
6.71 / 7.11 [16.4]
-
20
3
30
30
1.6
SUZ-KA60VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.97 / 1.87
1.79 / 1.50
9.75
10.11 / 8.71 [16.4]
-
20
3
30
30
1.8
SUZ-KA71VA2
55 / 55
53
840
330
880
220-240v, 50Hz
Single
2.19 / 2.07
1.99 / 1.66
8.89
9.46 / 9.36 [16.6]
-
20
3
30
30
1.8
PUHZ-P100VHA3/YHA
54 / 50 (47)
75 / 77
950
330 + 30
943
220-240v, 50Hz /380-415v,50Hz
Single / 3
3.28 / 3.12
2.92 / 2.65
8 / 3
14.92 / 14.16 [28.9]
5.34 / 5.09 [13.9]
32 / 16
3 / 5
50
30
3.0
PUHZ-P125VHA3/YHA
55 / 51 (48)
99 / 101
950
330 + 30
1350
220-240v, 50Hz /380-415v,50Hz
Single / 3
4.11 / 4.09
3.66 / 3.48
11 / 4
18.23 / 18.48 [29]
6.54 / 6.51 [14]
32 / 16
3 / 5
50
30
4.5
PUHZ-P140VHA3/YHA
56 / 52 (49)
99 / 101
950
330 + 30
1350
220-240v, 50Hz /380-415v,50Hz
Single / 3
4.98 / 5.21
4.43 / 4.43
11 / 4
22.50 / 23.71 [30.6]
7.91 / 8.28 [14.1]
32 / 16
3 / 5
50
30
4.5
SUZ-KA / PUHZ-P - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg)
Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi1-Mi2-Hi
DIMENSIONS (mm) Width
(Grille) Depth
Height
WEIGHT (kg) Unit
Panel
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
GRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE
PLA-RP140BA2
16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.71
3.21 / 2.61
C / D
24-26-29-32
15.88 (5/8”)
9.52 (3/8”)
36-39-42-44
840 (950)
840 (950)
298 (35)
27
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP125BA
14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.71
3.41 / 3.01
B / B
22-25-28-31
15.88 (5/8”)
9.52 (3/8”)
34-36-39-41
840 (950)
840 (950)
298 (35)
25
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP100BA
11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.74
3.41 / 3.01
B / B
20-23-26-30
15.88 (5/8”)
9.52 (3/8”)
32-34-37-40
840 (950)
840 (950)
298 (35)
25
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP71BA
8.0 (0.9-10.2)
7.1 (0.9-8.1)
6.65 (0.75-8.5)
7.05 (0.9-8.05)
0.73
3.65 / 3.43
A / A
14-16-18-21
15.88 (5/8”)
9.52 (3/8”)
28-30-32-34
840 (950)
840 (950)
258 (35)
23
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP60BA
6.9 (0.9-8.0)
6.1 (1.1-6.3)
5.75 (0.75-6.65)
6.05 (1.1-6.25)
0.76
3.50 / 3.26
B / A
12-14-16-18
15.88 (5/8”)
6.35 (1/4”)
28-29-31-32
840 (950)
840 (950)
258 (35)
23
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP50BA
6.0 (0.9-7.2)
5.5 (1.1-5.6)
5.0 (0.75-6.0)
5.45 (1.1-5.55)
0.81
3.66 / 3.22
A / A
12-14-16-18
12.7 (1/2”)
6.35 (1/4”)
28-29-31-32
840 (950)
840 (950)
258 (35)
22
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP35BA
4.1 (0.9-5.0)
3.6 (1.0-3.9)
3.4 (0.75-4.15)
3.55 (1.0-3.85)
0.84
3.94 / 3.30
A / A
11-12-13-15
9.52 (3/8”)
6.35 (1/4”)
27-28-29-31
840 (950)
840 (950)
258 (35)
22
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
4-Way Blow Ceiling Cassette System
PLA-RP Standard Inverter Heat Pump
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
� Reduced draft air distribution, with independent vane control
� Filter lowering operation down to 4m(optional PLP-6BAJ grille required)
� Optional ‘I See Sensor’ for energy saving andsmooth temperature control throughout the room
� 3-phase Standard Inverters now available
Technical Information
Page 102
INDOOR UNIT PLA-RP71-125BA(2)(3)
Models A B
Size 71 241 258
Size 100-125 281 298
Upper View >
Lower View >
Side View >
Mr
SlimRange
PLA
-RPZubadan Inverter Heat Pump
Dimensions
Page 105
4-Way Blow Ceiling Cassette System
PLA-RP Zubadan Inver ter Heat Pump
Technical Information
� Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter
� Expanded Heating Operation - Will work effectively evenwhen the outdoor ambient air temperature is -25°C
� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins
� Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels
The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.
Zubadan sets a new standard in performance
Page 104
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal) [3 Phase]
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi1-Mi2-Hi
DIMENSIONS (mm) Width
(Grille) Depth
Height
WEIGHT (kg) Unit
Panel
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
GRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE
PLA-RP125BA2
14.0 (5.0-16.0)
12.5 (5.5-14.0)
13.85 (4.95-15.85)
11.5 (5.05-12.9)
0.71
3.92 / 3.30
A / A
22-25-28-31
15.88 (5/8”)
9.52 (3/8”)
34-36-39-41
840 (950)
840 (950)
298 (35)
27
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP100BA3
11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.74
4.41 / 4.10 [4.31 / 4.00]
A / A
20-23-26-30
15.88 (5/8”)
9.52 (3/8”)
32-34-37-40
840 (950)
840 (950)
298 (35)
26
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PLA-RP71BA2
8.0 (4.5-10.2)
7.1 (4.9-8.1)
7.9 (4.45-10.1)
6.55 (4.5-7.45)
0.73
4.21 / 3.66
A / A
14-16-18-21
15.88 (5/8”)
9.52 (3/8”)
28-30-32-34
840 (950)
840 (950)
258 (35)
23
6
Fed by Outdoor Unit
Single
6
4
PLP-6BA
PAR-21MAA
PUHZ-HRP71VHA2
52 / 51 (48)
120
950
330 + 30
1350
220-240v, 50Hz
Single
1.90 / 1.94
2.76 / 1.65
14
8.76 / 8.89 [30]
-
32
3
75
30
5.5
PUHZ-HRP100VHA2/YHA2
52 / 51 (48)
120 / 134
950
330 + 30
1350
220-240v, 50Hz / 380-415,50Hz
Single / 3
2.54 / 2.44 [2.60 / 2.50]
3.68 / 2.07 [3.77 / 2.13]
14 / 3
11.76 / 11.26 [36]
4.86 / 4.69 [14]
40 / 16
3 / 5
75
30
5.5
PUHZ-HRP125YHA2
52 / 51 (48)
134
950
330 + 30
1350
380-415,50Hz
3
3.57 / 3.79
5.18 / 3.22
3
-
6.37 / 6.70 [14]
16
5
75
30
5.5
PUHZ-HRP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
[3 Phase] Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
Mr
SlimRange
PC
A-R
PPower Inverter Heat Pump
Dimensions
Page 107
84
88
195 230
57
254
476
680
182 85 878
960 2 2 853
5
10 51
236
PCA-RP50KAQ
8488
195 230
5725
447
668
0
182 851198
1280 221173 5
1
510
51
236
PCA-RP60-71KAQ
8488
195 230
5725
447
668
0
182 851518
1600 221493 5
1051
236
PCA-RP100-140KAQ
Lower View >
Side View >Front View >
Lower View >
Side View >Front View >
Lower View >
Side View >Front View >
PCA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi1-Mi2-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PCA-RP140KAQ
16.0 (5.7-18.0)
14.0 (6.2-15.3)
13.6 (4.85-15.3)
12.9 (5.7-14.1)
0.71
3.61 / 3.21
A / A
24-26-29-32
15.88 (5/8”)
9.52 (3/8”)
41-43-45-48
1600
680
230
39
Fed by Outdoor Unit
Single
6
4
PCA-RP125KAQ
14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.72
3.61 / 3.22
A / A
23-25-27-29
15.88 (5/8”)
9.52 (3/8”)
39-41-43-45
1600
680
230
38
Fed by Outdoor Unit
Single
6
4
PCA-RP100KAQ
11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.77
3.71 / 3.80
A / A
22-24-26-28
15.88 (5/8”)
9.52 (3/8”)
37-39-41-43
1600
680
230
36
Fed by Outdoor Unit
Single
6
4
PCA-RP71KAQ
8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.76
3.62 / 3.62
A / A
16-17-18-20
15.88 (5/8”)
9.52 (3/8”)
35-37-39-41
1280
680
230
32
Fed by Outdoor Unit
Single
6
4
PCA-RP60KAQ
7.0 (2.8-8.2)
6.0 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.81
3.61 / 4.00
A / A
15-16-17-19
15.88 (5/8”)
9.52 (3/8”)
33-35-37-40
1280
680
230
32
Fed by Outdoor Unit
Single
6
4
PCA-RP50KAQ
5.5 (2.5-6.6)
5.0 (2.3-5.6)
4.7 (2.15-5.6)
4.6 (2.1-5.15)
0.79
3.62 / 3.21
A / A
10-11-13-15
12.7 (1/2”)
6.35 (1/4”)
32-34-37-40
960
680
230
25
Fed by Outdoor Unit
Single
6
4
Ceiling Suspended System
PCA-RP Power Inverter Heat Pump
� Indoor unit designed for direct ceiling suspension
� Flush to wall installation for concealmentof service connections
PUHZ-RP50VHA4
46 / 44 (41)
42
800
300 + 23
600
220-240v, 50Hz
Single
1.52 / 1.56
1.35 / 1.33
5
6.96 / 7.14 [13.4]
-
16
3
50
30
2.5
PUHZ-RP60VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
1.94 / 1.50
1.73 / 1.28
5
8.82 / 6.84 [19.4]
-
20
3
50
30
3.5
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
2.21 / 1.96
1.97 / 1.67
5
10.06 / 8.94 [19.4]
-
20
3
50
30
3.5
PUHZ-RP100VKA/YKA
51 / 49 (46)
116 / 124
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
3.02 / 2.63
2.69 / 2.24
5
13.78 / 12.04 [27.2]
5.25 / 4.63 [8.7]
32 / 10
3 / 5
75
30
5.0
PUHZ-RP125VKA/YKA
52 / 50 (47)
116 / 126
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
3.88 / 3.88
3.45 / 3.30
5
17.66 / 17.66 [27.3]
6.67 / 6.67 [10.3]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP140VKA/YKA
52 / 50 (47)
118 / 132
1050
330 + 30
1338
220-240v, 50Hz / 380-415v,50Hz
Single / 3
4.43 / 4.36
3.94 / 3.71
5
20.13 / 19.82 [28.9]
7.63 / 7.52 [11.9]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
Technical Information
Page 106
Mr
SlimRange
PC
A-R
PStandard Inverter Heat Pump
Dimensions
Page 109
84
88
195 230
57
254
476
680
182 85 878
960 2 2 853
5
10 51
236
PCA-RP50KAQ
8488
195 230
5725
447
668
0
182 851198
1280 221173 5
1
510
51
236
PCA-RP60-71KAQ
8488
195 230
5725
447
668
0
182 851518
1600 221493 5
1051
236
PCA-RP100-140KAQ
Lower View >
Side View >Front View >
Lower View >
Side View >Front View >
Lower View >
Side View >Front View >SUZ-KA50VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
1.71 / 1.66
1.56 / 1.33
6.75
6.72 / 7.12 [16.4]
-
20
3
30
30
1.6
SUZ-KA60VA2
55 / 53
53
840
330
850
220-240v, 50Hz
Single
2.02 / 1.77
1.84 / 1.42
9.75
10.14 / 8.74 [16.4]
-
20
3
30
30
1.8
SUZ-KA71VA2
55 / 55
53
840
330
880
220-240v, 50Hz
Single
1.96 / 2.06
1.78 / 1.65
8.89
9.37 / 9.27 [16.5]
-
20
3
30
30
1.8
PUHZ-P100VHA3/YHA
54 / 50 (47)
75 / 77
950
330 + 30
943
220-240v, 50Hz / 380-415v,50Hz
Single / 3
3.28 / 3.13
2.92 / 2.66
8 / 3
15.73 / 14.09 [28.7]
5.33 / 5.09 [13.7]
32 / 16
3 / 5
50
30
3.0
PUHZ-P125VHA3/YHA
55 / 51 (48)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v,50Hz
Single / 3
4.12 / 4.09
3.67 / 3.48
11 / 4
18.55 / 18.42 [28.8]
6.54 / 6.50 [13.8]
32 / 16
3 / 5
50
30
4.5
PUHZ-P140VHA3/YHA
56 / 52 (49)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v,50Hz
Single / 3
4.69 / 4.84
4.17 / 4.11
11 / 4
21.09 / 21.97 [30.4]
7.44 / 7.67 [13.9]
32 / 16
3 / 5
50
30
4.5
SUZ-KA / PUHZ-P - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg)
Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.
PCA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Mi1-Mi2-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PCA-RP140KAQ
16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.71
3.41 / 2.81
B / C
24-26-29-32
15.88 (5/8”)
9.52 (3/8”)
41-43-45-48
1600
680
230
39
Fed by Outdoor Unit
Single
6
4
PCA-RP125KAQ
14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.72
3.40 / 3.01
C / B
23-25-27-29
15.88 (5/8”)
9.52 (3/8”)
39-41-43-45
1600
680
230
38
Fed by Outdoor Unit
Single
6
4
PCA-RP100KAQ
11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.77
3.41 / 3.00
B / C
22-24-26-28
15.88 (5/8”)
9.52 (3/8”)
37-39-41-43
1600
680
230
36
Fed by Outdoor Unit
Single
6
4
PCA-RP71KAQ
7.9 (0.9-10.2)
7.1 (0.9-8.1)
6.55 (0.75-8.5)
7.05 (0.9-8.05)
0.76
4.03 / 3.45
A / A
16-17-18-20
15.88 (5/8”)
9.52 (3/8”)
35-37-39-41
1280
680
230
32
Fed by Outdoor Unit
Single
6
4
PCA-RP60KAQ
6.9 (0.9-8.0)
5.7 (1.1-6.3)
5.75 (0.75-6.65)
5.65 (1.1-6.25)
0.81
3.42 / 3.22
B / A
15-16-17-19
15.88 (5/8”)
6.35 (1/4”)
33-35-37-40
1280
680
230
32
Fed by Outdoor Unit
Single
6
4
PCA-RP50KAQ
5.5 (0.9-6.6)
5.0 (1.1-5.6)
4.55 (0.75-5.5)
4.95 (1.1-5.55)
0.79
3.22 / 3.01
C / B
10-11-13-15
12.7 (1/2”)
6.35 (1/4”)
32-34-37-40
960
680
230
25
Fed by Outdoor Unit
Single
6
4
Ceiling Suspended System
PCA-RP Standard Inverter Heat Pump
The new Standard Inverter range provides inverter solutions forcustomers who want all the benefits that inverters offer, but donot have the budget available for the Power Inverter range.
Technical Information
� Indoor unit designed for direct ceiling suspension
� Flush to wall installation for concealmentof service connections
� 3-phase Standard Invertersnow available
Page 108
INDOOR UNIT PCA-RP71HAQ
INDOOR UNIT PCA-RP125HAQ
Front View >
Side View >
Lower View >
12241180
986
1136
110102
75
1136
650
258
650
280
1608
13701520
110102
75
1564
1520
650
258
650
280
Side View >
Front View >
Lower View >
Mr
SlimRange
PC
A-R
P-H
AQPower Inverter Heat Pump
Dimensions
Page 111
PCA-RP71HAQ
7.6 (3.5-10.2)
7.1 (3.3-8.1)
6.45 (3.0-8.65)
6.55 (3.05-7.45)
0.74
3.41 / 3.21
B / A
17-19
15.88 (5/8”)
9.52 (3/8”)
34-38
1136
650
280
41
Fed by Outdoor Unit
Single
6
4
PCA-RP125HAQ
13.8 (5.0-16.0)
12.5 (5.5-14.0)
11.75 (4.25-13.6)
11.5 (5.05-12.9)
0.77
3.41 / 3.22
B / A
30-38
15.88 (5/8”)
9.52 (3/8”)
44-50
1520
650
280
56
Fed by Outdoor Unit
Single
6
4
PCA-RP-HAQ - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
Stainless Steel Ceiling Suspended System
PCA-RP-HAQ Power Inverter Heat Pump
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
2.23 / 2.21
1.98 / 1.88
5
10.02 / 9.93 [19.4]
-
20
3
50
30
3.5
PUHZ-RP125VKA/YKA
52 / 50 (47)
116 / 126
1050
330 + 30
1338
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
4.05 / 3.88
3.60 / 3.30
5
18.18 / 17.42 [27.7]
7.14 / 6.87 [10.7]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (KW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
The PCA-RP-HAQ series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.
� High performance oil mist filter
� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed
� Optional decoration covers
Technical Information
Page 110
INDOOR UNIT PCA-RP125HAQ
1608
13701520
110102
75
1564
1520
650
258
650
280
Side View >
Front View >
Lower View >
Mr
SlimRange
PC
A-R
P-H
AQStandard Inverter Heat Pump
Dimensions
Page 113
PCA-RP125HAQ
13.8 (5.0-16.0)
12.3 (5.5-14.0)
11.75 (4.25-13.6)
11.3 (5.05-12.9)
0.78
3.21 / 2.81
C / C
30-38
15.88 (5/8”)
9.52 (3/8”)
44-50
1520
650
280
56
Fed by Outdoor Unit
Single
6
4
PCA-RP-HAQ - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
Stainless Steel Ceiling Suspended System
PCA-RP-HAQ Standard Inverter Heat Pump
PUHZ-P125VHA3/YHA
55 / 51 (48)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
4.30 / 4.38
3.83 / 3.72
11 / 4
19.11 / 19.47 [29.2]
6.73 / 6.86 [14.2]
32 / 16
3 / 5
50
30
4.5
PUHZ-P - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (KW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
The new Standard Inverter range provides inverter solutions forcustomers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
� High performance oil mist filter
� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed
� Optional decoration covers
� 3-phase Standard Inverters now available
Technical Information
Page 112
INDOOR UNIT PSA-RP71GA
INDOOR UNIT PSA-RP100-125GA
Front View > Side View > Upper View >
Front View > Side View > Upper View >
Mr
SlimRange
PSA
-RPPower Inverter Heat Pump
Dimensions
Page 115
PSA-RP71GA
7.6 (3.5-10.2)
7.1 (3.3-8.1)
6.45 (3.0-8.65)
6.55 (3.05-7.45)
0.73
3.41 / 3.23
B / A
15-18
15.88 (5/8”)
9.52 (3/8”)
40-45
600
270
1900
43
Fed by Outdoor Unit
Single
6
4
PSA-RP100GA
11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.81
3.41 / 3.34
B / A
24-31
15.88 (5/8”)
9.52 (3/8”)
44-49
600
350
1900
51
Fed by Outdoor Unit
Single
6
4
PSA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK )
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
Floor Standing System
PSA-RP Power Inverter Heat Pump
PUHZ-RP71VHA4
48 / 47 (44)
67
950
330 + 30
943
220-240v, 50Hz
Single
2.23 / 2.20
1.98 / 1.87
5
9.98 / 9.85 [19.7]
-
20
3
50
30
3.5
PUHZ-RP100VKA/YKA
51 / 49 (46)
116 / 124
1050
330 + 30
1338
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.28 / 2.99
2.92 / 2.54
5
14.69 / 13.39 [27.6]
5.83 / 5.37 [9.1]
32 / 10
3 / 5
75
30
5.0
PSA-RP125GA
14.0 (5.0-16.0)
12.4 (5.5-14.0)
11.9 (4.25-13.6)
11.4 (5.05-12.9)
0.75
3.41 / 3.01
B / B
26-33
15.88 (5/8”)
9.52 (3/8”)
46-51
600
350
1900
51
Fed by Outdoor Unit
Single
6
4
PUHZ-RP125VKA/YKA
52 / 50 (47)
116 / 126
1050
330 + 30
1338
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
4.11 / 4.12
3.66 / 3.50
5
18.40 / 18.44 [27.7]
7.24 / 7.25 [10.7]
32 / 16
3 / 5
75
30
5.0
PUHZ-RP - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (KW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 30m
Technical InformationNote:When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
The PSA-RP Floor Standing System complements the MitsubishiElectric range of indoor units. The sleek, modern design of this unitis ideal for numerous applications including bars and restaurants.
� Built in controller
Page 114
INDOOR UNIT PSA-RP100-125GA
Front View > Side View > Upper View >
Mr
SlimRange
PSA
-RPStandard Inverter Heat Pump
Dimensions
Page 117
PSA-RP125GA
14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.76
2.81 / 2.81
D / C
26-33
15.88 (5/8”)
9.52 (3/8”)
46-51
600
350
1900
51
Fed by Outdoor Unit
Single
6
4
PSA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
SHF (nominal & UK)
COP / EER (nominal)
ENERGy LABEL Heating/Cooling
AIRFLOW (m3/min) Lo-Hi
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA) Lo-Hi
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES
PSA-RP Standard Inverter Heat Pump
PUHZ-P125VHA3/YHA
55 / 51 (48)
99 / 101
950
330 + 30
1350
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
4.98 / 4.38
4.43 / 3.72
11 / 4
22.08 / 19.42 [29.2]
7.78 / 6.84 [14.2]
32 / 16
3 / 5
50
30
4.5
PSA-RP100GA
11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.83
3.41 / 3.01
B / B
24-31
15.88 (5/8”)
9.52 (3/8”)
44-49
600
350
1900
51
Fed by Outdoor Unit
Single
6
4
PUHZ-P100VHA3/YHA
54 / 50 (47)
75 / 77
950
330 + 30
943
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
3.28 / 3.12
2.92 / 2.65
8 / 3
14.55 / 13.84 [29.1]
5.23 / 4.97 [14.1]
32 / 16
3 / 5
50
30
3.0
PUHZ-P - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA) Heating/Cooling (silent)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
SySTEM POWER INPUT (KW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SySTEM RUNNING CURRENT (A) Single Phase
Heating/Cooling [MAX] 3 Phase
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg)
Floor Standing System
Technical Information
The Standard Inverter range provides inverter solutions for customerswho want all the benefits that inverters offer, but do not have the budgetavailable for the Power Inverter range.
The PSA-RP Floor Standing System complements the Mitsubishi Electricrange of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.
� Built in controller
� 3-phase Standard Inverters now available
Note:When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Page 116
Notes: All units charged to 20m (100) and 30m (125) pipe length.
PHV1000 DXE PHV1500 DXE PHV2000 DXE
AIR CURTAIN PHV1000/1500/2000R DXE
Mr
SlimRange
Dimensions
PH
V D
XEAir Curtain
AIR CURTAIN PHV1000/1500/2000 DXE
Rear View >
Upper View >
Page 119
Side View >
Rear View >
Upper View >
Side View >
PHV DXE Heat Pump Air CurtainHeat Pump Air Curtain System
In collaboration with Thermoscreens®, Mitsubishi Electric have developed a range of air cur tains that can beconnected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric methodassociated with air cur tains.
� Reduced CO2 emissions (up to 67%)
� Reduced Running Costs (up to 67%)
� 2.5 year payback period against equivalentElectric system
� Inverter technology (does not waste energy)
� Range of different sizes to suit every application
� Allows open door policy in retail outletswhilst being energy efficient
� Clean environment - protection from dust, fumes etc
� Comfortable climate for customers
� Easy to install and maintain
Page 118
PHV DXE - RECESSED
MODEL REFERENCE
DIMENSIONS (mm) (WxDxH)
SUPPLy (50Hz)
HEAT OUTPUT (kW) 100% / 50%
COP 100% / 50%
LOADING (amps)
VELOCITy (m/s)
AIR VOLUME (m3/h)
WEIGHT (kg)
NOISE dB(A) @ 3m
MAX. MOUNTING HEIGHT (m)
OUTDOOR UNIT MODEL
PHV1500R DXE HO
1650x436x296
415V*1
14.4 / 8.3
2.5 / 3.7
12.7*1
9
2600
67
58
3.5
PUHZ-RP140VKA/yKA
PHV2000R DXE LO
2240x436x296
415V*2
14.1 / 7.9
2.9 / 3.7
15.7*2
9.5
3300
85
59
3.5
PUHZ-RP100VKA/yKA
PHV2000R DXE HO
2240x436x296
415V*2
21.3 / 11.2
2.4 / 3.2
15.7*2
9
3130
88
59
3.5
PUHZ-RP200yKA
Technical Information
PHV DXE - FREE STANDING
MODEL REFERENCE
DIMENSIONS (mm) (WxDxH)
SUPPLy (50Hz)
HEAT OUTPUT (kW) 100% / 50%
COP 100% / 50%
LOADING (amps)
VELOCITy (m/s)
AIR VOLUME (m3/h)
WEIGHT (kg)
NOISE dB(A) @ 3m
MAX. MOUNTING HEIGHT (m)
OUTDOOR UNIT MODEL
PHV1500 DXE HO
1746x377x255
415V*1
14.4 / 8.3
2.5 / 3.7
12.7*1
9
2600
60
58
3.75
PUHZ-RP140VKA/yKA
PHV2000 DXE LO
2296x377x255
415V*2
14.1 / 7.9
2.9 / 3.7
15.7*2
9.5
3300
78
59
3.75
PUHZ-RP100VKA/yKA
PHV2000 DXE HO
2296x377x255
415V*2
21.3 / 11.2
2.4 / 3.2
15.7*2
9
3130
80
59
3.75
PUHZ-RP200yKA
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
HEAT PUMP OUTDOOR UNITSMODEL REFERENCE
DIMENSIONS (mm) (WxDxH)
SUPPLy (50Hz)
MAX. CURRENT (A)
FUSE SIZE HRC (BS88)
MAX. PIPE RUN Length (m)
Height (m)
PIPE SIZES Gas mm(in)
Liquid mm(in)
INTERCONNECTING CABLE
PUHZ-RP100VKA/YKA
1050x330+30x1338
230V / 415V
26.5 / 8
32 / 10
50
30
15.88 (5/8)
9.52 (3/8)
2 core
PHV1500R DXE LO
1650x436x296
415V*1
10.1 / 5.6
2.3 / 3.4
12.7*1
9
2500
66
58
3.5
PUHZ-RP71VHA4
PHV1000R DXE HO
1150x436x296
415V*1
8.6 / 5.34
2.4 / 3.15
7.8*1
9
1400
45
56
3.5
PUHZ-RP71VHA4
PHV1500 DXE LO
1746x377x255
415V*1
10.1 / 5.6
2.3 / 3.4
12.7*1
9
2500
59
58
3.75
PUHZ-RP71VHA4
PHV1000 DXE HO
1196x377x255
415V*1
8.6 / 5.34
2.4 / 3.15
7.8*1
9
1400
39
56
3.75
PUHZ-RP71VHA4
PUHZ-RP71VHA4
950x330+30x943
230V
19
20
50
30
15.88 (5/8)
9.52 (3/8)
2 core
PUHZ-RP140VKA/YKA
1050x330+30x1338
230V / 415V
28 / 11
32 / 16
50
30
15.88 (5/8)
9.52 (3/8)
2 core
PUHZ-RP200YKA
1050x330+30x1338
415V
19
20
100
30
28.58 (1 1/8)
9.52 (3/8)
2 core
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
INDOOR UNIT PHV2000 NT
Mr
SlimRange
Dimensions
PH
V N
TSensible Cooling
Chilled Water Heat Pump
Rear View >
Upper View >
Page 121
Side View >
Upper View >
PHV NT Chilled Water Heat PumpSensible Cooling Wall Mounted System
In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unitthat can be connected to our air to water heat pumps in cooling mode. These systems offer 100% sensiblecooling (SHF of 1) for use in server rooms and other sensible cooling applications.
� SHF of 1 and capacity validated by 3rd party assessment (BSRIA)
� Reduced CO2 emissions
� Reduced Running Costs
� Inverter technology (does not waste energy)
� Easy to install and maintain
� Ideal for small to medium size server rooms / laboratories
� No 3rd party humidifier is required
� PAR-W21MAA controller included
� Pump not included
Page 120
Technical Information
PHV NT - INDOOR UNITS
MODEL REFERENCE
DIMENSIONS (mm) Width
Depth
Height
CAPACITy (kW) Cooling
SHF
EER
ELECTRICAL SUPPLy
PHASE
LOADING (A)
VELOCITy (m/s)
AIR VOLUME (m3/h)
WEIGHT (kg)
NOISE (dBA) @ 3m
WATER VOLUME FLOW RATE (m3/h)
HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)
WATER VOLUME OF COIL (litres)
PUHZ-HW140YHA2
53
148
1020
330 + 30
1350
380-415v, 50Hz
3
100
15
2.5
7.6 [13]
16
5
4.3
-5ºC ~ +46ºC
PHV2000 NT
2296
377
255
12.0
1.0
3.8
220-240v, 50Hz
Single
2.7
9
2885
90
59
3.18
36
5.1
PUHZ-HW140VHA2
53
134
1020
330 + 30
1350
220-240v, 50Hz
Single
100
15
2.5
22.2 [35]
40
3
4.3
-5ºC ~ +46ºC
PUHZ-HW - OUTDOOR UNITS
MODEL REFERENCE
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLy
PHASE
AIRFLOW (m3/min)
HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)
WATER VOLUME IN HEAT EXCHANGER (litres)
RUNNING CURRENT (A) [MAX]
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
CHARGE R410A (kg)
OPERATING RANGE
Notes:Water flow temperature to be set to 10ºC (cannot be set lower). Includes room/return air temperature control, remote On/Off and room over-heat alarm.Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA assessment.
C. 1
50m
in.
for p
ipes
255
295
OUTDOOR UNIT PUHZ-HW140VHA2 / PUHZ-HW140yHA2
Upper View >
Side View >
VH
A
YH
A93
1
1079
23
371
635
1350
3221020
34
7440
Front View >
Installation Feet
Rear Air Intake
Air Discharge
Side Air Intake
2853
370
19
417
210600210
330
30
168
36
Outdoor Heat Pump
PUHZ-RP71
PUHZ-HRP71
PUHZ-P100
PUHZ-RP100
PUHZ-HRP100
PUHZ-P125
PUHZ-RP125
PUHZ-HRP125
PUHZ-P140
PUHZ-RP140
PUHZ-P140
PUHZ-RP140
PUHZ-P200
PUHZ-P200
PUHZ-P200
PUHZ-RP200
PUHZ-RP200
PUHZ-RP200
PUHZ-P250
PUHZ-P250
PUHZ-P250
PUHZ-RP250
PUHZ-RP250
PUHZ-RP250
Total Heating Capacity (kW)
3.5 - 10.2
4.5 - 10.2
4.5 - 12.5
4.5 - 14.0
4.5 - 14.0
5.0 - 16.0
5.0 - 16.0
5.0 - 16.0
5.0 - 18.0
5.0 - 18.0
5.0 - 18.0
5.0 - 18.0
9.5 - 25.0
9.5 - 25.0
9.5 - 25.0
9.5 - 25.0
9.5 - 25.0
9.5 - 25.0
12.5 - 31.5
12.5 - 31.5
12.5 - 31.5
12.5 - 31.5
12.5 - 31.5
12.5 - 31.5
Total Cooling Capacity (kW)
3.3 - 8.1
4.9 - 8.1
4.9 - 11.2
4.9 - 11.4
4.9 - 11.4
5.5 - 14.0
5.5 - 14.0
5.5 - 14.0
5.5 - 15.0
5.5 - 15.3
5.5 - 15.0
5.5 - 15.3
9.0 - 22.4
9.0 - 22.4
9.0 - 22.4
9.0 - 22.4
9.0 - 22.4
9.0 - 22.4
11.2 - 28.0
11.2 - 28.0
11.2 - 28.0
11.2 - 28.0
11.2 - 28.0
11.2 - 28.0
Pipe Kit Part Number
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDD-50TR-E
MSDT-111R-E
MSDT-111R-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
Multi-Split Systems - Combinations Table
Indoor Unit
Size 35
Size 35
Size 50
Size 50
Size 50
Size 60
Size 60
Size 60
Size 71
Size 71
Size 50
Size 50
Size 100
Size 60
Size 50
Size 100
Size 60
Size 50
Size 125
Size 71
Size 60
Size 125
Size 71
Size 60
No. of Indoor Units
2
2
2
2
2
2
2
2
2
2
3
3
2
3
4
2
3
4
2
3
4
2
3
4
Technical Information
Mul
ti-S
plit S
yste
ms
Mr
SlimRange
Page 123
Inverter Heat Pump
Mr Slim Multi-Split Systems
IndoorUnits
Indoor Units
Outdoor UnitsOutdoor Units
Multi distributorPipes
Multi distributorPipes
BB
C
CD
h h
HH
Indoor Units
OutdoorUnits
Multi distributorPipes
C
DE
B
A
h
H
AA
QUADRUPLETRIPLETWIN
PIPE RUN PARAMETERS
Outdoor Model Pipe Runs Max. Pipe Run (m)
PUHZ-P100-140VHA3/yHA A+B+C twin 50
PUHZ-P200/250yHA3 A+B+C twin 70
PUHZ-RP71VHA4 A+B+C twin 50
PUHZ-RP100-140VKA/yKA A+B+C twin 75
PUHZ-RP200/250yKA A+B+C twin 80 (120)
PUHZ-HRP71-125VHA2/yHA2 A+B+C twin 75
PUHZ-P140VHA3/yHA A+B+C+D triple 50
PUHZ-P200/250yHA3 A+B+C+D triple 70
PUHZ-RP140VKA/yKA A+B+C+D triple 75
PUHZ-RP200/250yKA A+B+C+D triple 80 (120)
PUHZ-P200/250yHA3 A+B+C+D+E quadruple 70
PUHZ-RP200/250yKA A+B+C+D+E quadruple 80 (120)
PUHZ-P100-140VHA3/yHA B – C or C – D or B – D 8
PUHZ-RP71-140VHA4/VKA/yKA B – C or C – D or B – D 8
PUHZ-HRP71-125VHA2/yHA2 B - C 8
PUHZ-P200/250yHA3 B - C or B - D or B - E or C - D or C - E or D - E 8
PUHZ-RP200/250yKA B - C or B - D or B - E or C - D or C - E or D - E 8
H = 30m. h = 1m. Note: H for the PUHZ-RP200/250YKA = 40m
The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, wheretwo, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to asingle outdoor unit using twin, triple or quadruple multi distributor pipes.
� Twin, triple or quadruple indoor heat pump units can be operated inMulti-Split configuration from a single outdoor unit
� Heat pumps must operate in same heating or cooling mode
� Cooling capacity range 3.3 to 28kW
� Heating capacity range 3.5 to 31.5kW
� SLZ-KA indoor units can now be connected as part of a Mr Slim Multi-Split system
Note: SEZ-KD indoor units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP indoor units cannot be connected with indoor units of different type.PCA-RP, PSA-RP and SLZ-KA indoor units cannot be connected to PUHZ-HRP outdoor units.PKA-RP indoor units cannot be connected to PUHZ-HRP71 & PUHZ-HRP125 outdoor units.
Technical Information
≥
≥
≥
≥
≥
Page 122
h
Dimensions
Out
door
Uni
t D
imen
sions
Mr
SlimRange
Page 125
Outdoor Units
SUZ-KA50/60VA2
10
69
800
302.5
500 Bolt pitch for installation
150
22.3
55
0
28
0
16
4.5
99
.5 170.5
23
4335
Side View >
28
5
34
4.5 4
4
400
Air in
Air out
Air in
17
.5
Bo
lt p
itch
fo
rin
sta
llatio
n3
04
~3
25
40
SUZ-KA25/35VA2
Upper View >
Front View >
40
515299
66
3451
33
0
36
0
500
Air in
Air in
Air out
85
04
30
80121
840
3035
15
59
0
198
Upper View >
Front View > Side View >
Dimensions
Page 124
417
C D
E F
(19)
370
2853
175600175
330
Air Discharge
Rear Air Intake
Side Air Intake
Installation Feet
3023
943
473
950
322
447 A
B
F5654
E4541
D4241
C6656
B670589
PUHZ-P100VHA3PUHZ-P100YHA
A443431
Upper View >
Front View >
PUHZ-P100VHA3 / PUHZ-P100YHA
Side View >
SUZ-KA71VA2
Upper View >
Front View > Side View >
Out
door
Uni
t D
imen
sions
Mr
SlimRange
Page 127
DimensionsOutdoor Units
Dimensions
Page 126
PUHZ-RP60/71VHA4
40 54
2837
019
417
5357 41
600 175175
330
Rear air intake
Air discharge
Side air intakeInstallation Feet
29
322
950
473
943
23
447
431
673
Front View >
Upper View >
Side View >
Air intake
Air discharge
Air intake
43.6
152
155
400347.5
45.4
365
330
300
40
32.5
Front View >
Upper View >
600
10
300
150
287.5
Installation bolt pitch: 500800
69
18
35 43
183
90155
23
Side View >
PUHZ-RP35/50VHA4
Air Discharge
Rear Air Intake
Side Air Intake
600175 175
330
417
3761
535640
(19
)28
370
Installation Feet
30
1350
23
950
995
999
439
339 A
371
635
322
PUHZ-P200YHA3PUHZ-P250YHA3
A447421
PUHZ-P200YHA3PUHZ-P250YHA3
A447421
PUHZ-P200/250YHA3
Upper View >
Front View > Side View >
Air Discharge
Rear Air Intake
Side Air Intake
600175 175
330
417
4156
535441
(19
)28
370
Installation Feet
30
1350
23
950
A
447
431
371
635
322
PUHZ-P125/140VHA3PUHZ-P125/140YHA
A1076994
PUHZ-P125/140VHA3 / PUHZ-P125/140YHA
Upper View >
Front View > Side View >
PUHZ-P125/140VHA3PUHZ-P125/140YHA
A1076994
Rear air intake
Air discharge
Side air intake
Installation Feet
2837
0
6030
225225
330
600
417
19
70 42
40
53
56
0
632
450
A
369
362
26
1338
1050
442
Front View >
Upper View >
PUHZ-RP100-140VKA / PUHZ-RP100-140YKA
Side View >
PUHZ-RP100-140VK APUHZ-RP100-140YK A
Model
9191067
A
PUHZ-RP200/250YKA
Rear air intake
Air discharge
Side air intake
Installation Feet
2837
0
6030
225225
330
600
417
19
70 42
40
53
56
0
1050
632
369
26
1338
362
982
986
A B342
Front View >
Upper View >
Side View >
PUHZ-RP200YKAPUHZ-RP250YKA
Model
442-B
424450A
Out
door
Uni
t D
imen
sions
Mr
SlimRange
Page 129
Outdoor Units
Dimensions
Page 128
PUHZ-HRP71/100VHA2 / PUHZ-HRP100/140YHA2
Dimensions
Air discharge
Rear air intake
Side air intake
600175 175
330
417
4266
535645
(19
)28
370
Installation Feet
30
23
A
443
447
635
371
1350
322
950
Front View >
Upper View >
Side View >
HRP.VHA2
HRP.YHA2
1079
A
930
Page 130
Accessories / Optional ExtrasM Series
Wall Mounted Units S70 515 716 - Terminal blockS71 000 028 - CN22 connector
Ceiling Concealed Ducted Units MAC-399IF - Interface for connection to M-NET System SEZ-KD25-71VAQMAC-397IF - Interface for group control and run/fault SEZ-KD25-71VAQ
4-Way Blow Cassette Units PLP-6BA - Grille for PLA-RP35-140BA(2)(3)SLP-2AAW - Grille for SLZ-KA25-50VAQPAC-SH53TM-E - Multi function casement PLA-RP35-140BA(2)(3) for fresh air 100mm knockout or
to hold the high efficiency filter optionPAC-SH59KF-E - High efficiency filter PLA-RP35-140BA(2)(3)PLP-6BALM - Grille and infra-red controller PLA-RP35-140BA(2)(3)PLP-6BAJ - Grille with filter lowering function PLA-RP35-140BA(2)(3)PAC-SA1ME-E - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)(3)PAR-SA9FA-E - Infra-red signal receiver PLA-RP35-140BA(2)(3)S70E40714 - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)(3)MAC-399IF - Interface for connection to M-NET System SLZ-KA25-50VAQMAC-397IF - Interface for group control and run/fault SLZ-KA25-50VAQ
Ceiling Suspended Units PAR-SL94B-E - Wireless remote controller and adaptorPAC-SH83DM-E - Optional drain lift pump PCA-RP50KAQPAC-SH85DM-E - Optional drain lift pump PCA-RP60KAQPAC-SH84DM-E - Optional drain lift pump PCA-RP71-140KAQPAC-SG38KF-E - Oil mist filter for PCA-RP71/125HAQ (12 pack)PAC-SF81KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP71HAQPAC-SF82KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP125HAQ
Outdoor Units PAC-SG61DS-E - Drain socket set PUHZ-RP35-250VHA4/VKA/YKA / PUHZ-P100-250VHA3/YHA/YHA3 / PUHZ-HRP71-125VHA2/YHA2
PAC-SG58SG-E - Air outlet guide PUHZ-RP35-50VHA4PAC-SG59SG-E - Air outlet guide PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA /
PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required)PAC-SH96SG-E - Air outlet guide PUHZ-RP100-250VKA/YKA (2 sets required)PAC-SG56AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP35-50VHA4PAC-SH63AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA /
PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required)PAC-SH95AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP100-250VKA/YKA (2 sets required)
System Control Units PAC-SA89TA-E - Remote on/off adaptorPAC-SF40RM-E - Run/fault indicationPAC-SE41TS-E - Remote sensorPAC-SF81MA - A/M-NET adaptorPAC-YT51CRB - Simplified remote controllerPAR-30MAA - Wired controllerPAC-SK82SI-E - Sub interface board
Pipe Kits MSDD-50TR-E - Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140MSDD-50WR-E - Multi distribution pipe twin units - 50:50 - sizes 200/250MSDT-111R-E - Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250MSDF-1111R-E - Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250
Power Supply Terminal Kits PAC-SH52HR-E - Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YKAPAC-SG94HR-E - Power supply terminal kit for PKA-RP when using PUHZ-RP200/250YKAPAC-SG96HR-E - Power supply terminal kit for PCA-RP / PSA-RP when using PUHZ-RP200/250YKAPAC-SG97HR-E - Power supply terminal kit for PEAD-RP / PCA-RP-HAQ when using PUHZ-RP200/250YKA
Air
Han
dlin
g U
nit
Cont
rolle
r /
Acc
esso
ries
/ O
ptio
nal Ex
tras
Mr
SlimRange
Page 131
Air Handling Unit Controller
PAC-IF012B-E
PAC-IF012B-EMITSUBISHI ELECTRIC OUTDOOR UNIT
CAPACITy (kW) Heating (nominal)
Cooling (nominal)
AUTO STEP PUHZ-RP
PUHZ-P
SUZ-KA
PUHZ-HRP
MANUAL STEP PUHZ-RP
PUHZ-HRP
PIPE SIZE (mm) PUHZ-(H)(R)P
Gas / Liquid SUZ-KA
HEAT EXCHANGER Max Capacity
Min Capacity
DIMENSIONS (mm) Width
Depth
Height
WEIGHT (kg)
SIZE 35
4.1
3.6
VHA4
-
VA2
VHA4
12.7 / 6.35
9.52 / 6.35
1050
350
336
69
278
2.5
SIZE 50
6.0
5.0
VHA4
-
VA2
VHA4
12.7 / 6.35
12.7 / 6.35
1500
500
336
69
278
2.5
SIZE 60
7.0
6.0
VHA4
-
VA2
VHA4
15.88 / 9.52
15.88 / 6.35
1800
600
336
69
278
2.5
SIZE 71
8.0
7.1
VHA4
-
VA2
VHA2
VHA4
VHA2
15.88 / 9.52
15.88 / 9.52
2130
710
336
69
278
2.5
SIZE 100
11.2
10.0
VKA/yKA
VHA3/yHA
-
VHA2/yHA2
VKA/yKA
VHA2/yHA2
15.88 / 9.52
-
3000
1000
336
69
278
2.5
SIZE 125
14.0
12.5
VKA/yKA
VHA3/yHA
-
yHA2
VKA/yKA
yHA2
15.88 / 9.52
-
3750
1250
336
69
278
2.5
SIZE 140
16.0
14.0
VKA/yKA
VHA3/yHA
-
VKA/yKA
15.88 / 9.52
-
4200
1400
336
69
278
2.5
SIZE 200
22.4
19.0
yKA
yHA3
-
yKA
28.58 / 9.52
-
6000
2000
336
69
278
2.5
SIZE 250
27.0
22.0
yKA
yHA3
-
yKA
28.58 / 12.7
-
7500
2500
336
69
278
2.5
The Air Handling Unit Controllers are an interface to allow connection to third party manufacturerequipment.
Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required.
� No need for expansion device
� Error, operation and defrost output
� Demand control by analogue or digital inputs
(0-10Ω, 4-20mA , 1-5V, 0-10V, Step, Auto-Step)
� Now includes a third thermistor to enable Auto-Step
Note: One air handling unit controller is required per air handling unitCooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WBHeating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB
A Control wiring Thermistor wiring
Piping
Air Handling Unit (field supplied)
Controller (field supplied)
Outdoor Unit (Mitsubishi Electric)
Air Handling Unit Controller (Mitsubishi Electric)
Example:
Technical Information
VOLUME (cm3)
City Mult i Energy EfficientVRF Systems
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
The City Multi Range:Solutions for More Demanding Applications
Page 135
Eff icient and FlexibleThe City Multi range is Mitsubishi Electric’s answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiencyof City Multi is second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.
The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate.
Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2 systems. This is achievedthrough only two pipes rather than the conventional three. Further developments with the City Multi range now enable heat to bemoved to areas of a building that can best make use of it, these include air curtains and the generation of hot water. By moving heatin this way the system becomes central to providing a wider range of environmental services and further increases the run cost andCO2 emission reductions you would normally expect, as well as generating the hot water from this renewable heat source. By usingMitsubishi Electric’s 2-pipe heat recovery technology, substantial savings can again be made on annual running costs. With a range of over 80 indoor units, up to 50 (depending on the capacity available) can be connected to a YJM-A outdoor unit.
Broadening the range of potential City Multi applications is Mitsubishi Electric’s 4th generation water cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit but also via its water circuit, offering double heat recovery potential.
Sophisticated technology, combined with a high level of control and energy efficiency:City Multi is perfectly positioned to meet the demands of today’s market.
Page 134
The strength of
City MultiThe R410A YJM-A seriesoffers some of the highest
EER/COP ratings in the market.
Page 136
The Basics:
Our Answer to VRFMitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410Arefrigerant. The range has been specifically designed for today'sbuilding requirements and addresses key market issues such asenergy efficiency, adaptability and reliability. Mitsubishi Electricmanufactures the only 2-pipe heat recovery simultaneousheating and cooling system in the world and equally unique,a water-cooled version. With user fr iendly control systemsutilising internet technology and integrated cooling andventilation indoor units, City Multi is the benchmark and market leader in VRF technology.
What is InverterDriven Technology?Mitsubishi Electric spends more than 5% of its turnover onresearch and development, with our engineers always looking at ways in which we can improve and lead in air conditioningefficiency. The use of inverter technology in our City Multisystems is paramount in this process, working by varying thecompressor speed to match the cooling or heating load, therebyconsuming only the power necessary to match the exactrequirement of the room. When City Multi is operating atpartial load, the energy efficiency of the system is significantlyhigher than at full load. In a typical application partial loadconditions prevail for more than 90% of operation time.A fixed speed system can only operate at 100% capacity andcannot match the annual efficiencies of an inverter system
What is a Heat Pump System?Mitsubishi Electric’s City Multi Y and WY Series’ are heat pumpsystems, which provide either heating or cooling to a building atany given time.
What is a HeatRecovery System?Mitsubishi Electric’s City Multi R2 and WR2 Series’ have theability to provide heating and cooling at the same time in areasconnected to the same outdoor unit.
Page 137
What is VRF?VRF stands for Variable Refrigerant Flow. A VRF airconditioning system modulates the flow of refrigerantdepending upon the capacity requirements of the building.
A VRF system comprises of a condensing unit sitedexternally and a series of multiple indoor units to provide cooling and/or heating to the occupied space.
Why R410A?R410A is a more efficient refrigerant as it has a higher specificheat capacity when compared to R407c or R22. This higherenergy carrying capacity allows for smaller pipe sizes, longerpipe runs and reduces the volume of refrigerant within a system.
This is a major factor when complying with EN378, a Europeanstandard concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal of refrigerating systems.
Why Heat Recovery?Flexibility and efficiency are key factors when selecting a heatrecovery system. For example, while a heat pump system isadequate for a large open plan office, businesses that have amore partitioned structure to an office will require the needto simultaneously heat or cool different sections of the officeaccording to each users individual preferences.
The efficiency of this type of system comes from the ability touse the by-products of cooling and heating to transfer energywhere it is required, thus acting as a balanced heat exchangerachieving up to 20% cost savings over a conventional heatpump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower thanthose needed for a three pipe version. This helps to reduce installation costs, further increasing the savingsassociated with City Multi.
How Does the R2 / WR2Heat Recovery SystemOperate on 2 Pipe’s?
The secret of City Multi heat recoverysystems lies in the BC Controller
The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas forheating and liquid for cooling, all through the same pipe. Threepipe systems allocate a pipe to each of these phases. Whenthis mixture arrives at the BC Controller, it is separated andthe correct phase delivered to each indoor unit depending onthe individual requirement of either heating or cooling.
Comparison Example of Piping Connection Sites
Heat Interchange CircuitTo further enhance the class leading efficiency of City Multi, theunique Heat Interchange Circuit provides extra sub cooling.This system allows optimum refrigerant distribution to multipleindoor units, by allowing more effective use of refrigerantflowing through the electronic expansion valves.
Because of the added efficiency, volumes of refrigerant in systemsare continuing to reduce.
The Difference Between YJM-A and PreviousMitsubishi Electric ModelsTechnology is key when increased efficiency isdemanded. The City Multi YJM-A range isdesigned to deliver this.
A highly efficient R410A scroll compressor design results inless friction losses at the motor. A simplified refrigerant circuit(low pressure loss) including new accumulator design also addsa few more points to the efficiency scale.
Enhancements to the heat interchange circuit, inverter drivenfan motor and heat exchanger design, again add vital increasesto overall system efficiency and COPs.
Total Energy Conservation
Comparison of COP (energy efficiency) of an 8hp YJM-A system.
31% 36%4.134.46
CITY MULTI REFRIGERANT
CIRCUIT
NORMAL REFRIGERANT
CIRCUIT
The Technology to MakeCity Multi the Natural Choice
City Multi Systems: 8-18hp
City Multi Systems: 20-36hp
City Multi Systems: 38-50hp
Page 138
City Multi R410A YJM-A TechnologyUsing the very latest in IPM (Intelligent Power Module)technology, precise control of energy input is achievedallowing City Multi to fur ther improve COPs for R410Asystems. IPM uses 1Hz steps of capacity control, matchingbuilding requirements through more accurate control of theoccupied space with reduced power input.
As in previous versions, IPM technology operates extremelyeffectively under part load conditions (50-80% of operatingcapacity), a condition that most systems will be in for theirnormal working life. Therefore the consideration of efficiency at part load is accounted for as well as when at peak loadconditions, offering high system efficiency all year round.
Stable and Smooth Operation:100% Inverter ControlAll City Multi compressors are inverter-driven andcapable of precisely matching a building's coolingand heating demands.
The outdoor unit combinations comprise of one module for 8-18hp systems, two modules for 20-36hp systems and threemodules for 38-50hp systems (Y series only). Each modulecarries one inverter compressor making simple and highly reliablecontrol possible. Not only does it allow low starting currents, the inverter driven compressor also provides precise indoorcomfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies
Energy efficiency has always been the driver for City Multi technological development that always delivers the quality and reliability needed for commercial air conditioning environments.Mitsubishi Electric spend more than 5% of their turnover on research and development, with ourengineers always looking at ways in which we can improve and lead in air conditioning efficiency.
Page 139
The Importance of COPCOP stands for “Co-efficient of Performance”. It is ameasure of the useful energy a system can deliver comparedto the energy that it consumes. It is calculated by dividing theenergy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be,with commensurate reduced running costs.
For Heat Pumps to be included on the Energy TechnologyProduct List under the Enhanced Capital Allowance scheme,they must fall within the criteria specified by the ECA. Forfurther information on qualification please visit www.eca.gov.uk
Total Energy Conservation
Ground SourceHeat Pumps
J
City MultiZubadanAir Source Heat Pumps
The City Multi Zubadan heat pumps achieve an excellent heating performance even when theoutdoor air temperature is as low as -25°C.
These models make use of a Flash Injection Circuit, which allows the optimal amount of refrigerant to be provided to the system viathe compressor through a specially designed injection port. In simple terms, the system allows a quick start up time and continuousheating; even in low ambient conditions.
Full heatingcapacity evenat -15°C
Capacityimprovementof 30%
Outdoor temp.°C (W.B.)
PUHY-HP250 YHM-A
Standard CITY MULTI
PUHY-P400 YSJM-A
Standard CITY MULTI
PUHY-P250 YJM-A
50.0
25.0
(kW)
10.0 -25 -20 -15 -10 -5 0 3
PUHY-HP400 YSHM-A
J
Ground Source Heat Pump installed insidethe building, typically one per floor
Bore holes absorb or reject heat from the ground
Flow and return water loop supplies water to and from the units
Indoor units provide heating or cooling
Example of a Closed Loop Bore Hole Application:
Smaller YHM-A models now available, in a wider variety
of sizes
Page 140
There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky):
� Open Loop - Large bodies of water can be utilised as a stable source of water at a relatively constant temperature. This can be either surface water or ground water. Surface water would include lakes, reservoirs, rivers and the sea.
� Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic spiral pipe is laid into the bottom. The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with theexcavated soil.
� Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, dependingon geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surroundedby a conductive grout.
A very efficient source of energy for water source heat pumpsystems is the Earth itself. Ground source heat pumps use the Earth's naturalsolar collection and heat storage capabilities as an infinite heat source/heat sink.At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter. Deeper downhowever, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant, dependable temperatures thatcan be harnessed using ground source heat pumps. The constant ground temperatures allow the heat pump to operate at optimumefficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extractedor rejected into the ground using water which is pumped through a network of plastic pipes.
Page 141
Expanded Heating OperationWill work effectively even when the outdoor ambient airtemperature is -25°C.
Stable Heating PerformanceFull heating capacity at -15°C, a 30% capacity improvementover the standard YJM-A model.
Stable OperationUtilising the new Flash Injection Circuit the Zubadan modelshave reduced defrost times and can provide continuousheating for up to 250 mins.
Quick Start-UpFull heating capacity is achieved in about 20 mins, improving comfort levels.
Refrigerant Volume Checking FunctionThis function runs the system, measuring various temperatures and pressures throughout thesystem, comparing these to the values stored in the units memory from the previous service. If a leakage has occurred the system will indicate so, enabling customers to easily comply with the F-Gas regulation.
Replace TechnologyThe latest VRF Replace Multi models from Mitsubishi Electric are specifically designed for thematuring refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilstalso allowing the upgrade to some of the most efficient systems available in the market.
Replace Multi will clean the existing pipework during commissioning, removing any depositsand R22 mineral oil that would have ordinarily meant that new pipework would have beencalled for. The implications of this are significant savings on cost and time, whilst alsominimising any potential disruption.
Cooling Operation Set Temperature of 14ºCEnvironments such as gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14ºC DB is possible on the floor standing and ducted models only. The indoor unit fan will be fixed at high speed during this operation.
New fan designReduction of operation noise
New control box designImprovement of reliability and easy maintenance
Features and BenefitsHigh Off Coil / High Sensible CoolingPoor design or application of air conditioning systems can sometimes lead to cold draughts and uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can create dry eyes and sore throats.
Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with this. By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants. Thesehigh SHF’s are available throughout the range of indoor units, allowing optimum selection of units tailored to more specific design criteria.
Page 142
Reduced Noise Levels:New Fan Design
City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs.Continuing the development in the areas of blade shape and weight, MitsubishiElectric have managed to achieve even higher performance and lower noise levels.
To reduce noise levels further and comply with inner city residential noiseregulations, all outdoor units include Night Set-back mode. This function works bylowering the fan speed and compressor frequency proportionally with reduction in demand (44dBA for PUHY-P250YJM-A). The compressor compartment is also now sealed, further reducing noise levels.
Page 143
Fine Control of theInverter ProvidesBetter Eff iciencyand PerformanceAir cooled inverters use the ambienttemperature to cool the inverter. Forwater cooled VRF (which are installedinside the building) refrigerant cooling is used to maintain accurate control of the Inverter.
New heat exchanger designA cross-steer fin structure with additionalslits helps to improve COP by up to 2% incooling. The heating COP is also improvedby 1% with the introduction of a 2.5 rowheat exchanger, improving airflow andtemperature valance.
New inverter compressorImprovement of COP and partial loadperformance thanks to the new concentrated winding structure.
Previous YHM-A
NewYJM-A
Slits
Fin Structure
Heat Exchanger
YHM-A: 3 rows YJM-A: 2.5 rows
Effective Use of SpaceYJM-A models have a smallerfoot print requirement when compared to the YGM-A models.The width and depth have beenreduced by 7% and 13% respectively, with the height being reduced by 130mm (PUHY-P250YJM-A compared to PUHY-P250YGM-A).
Blue Fin TreatmentThe anti-corrosion Blue Fin treatment of the heat exchanger is especiallyeffective in urban environments where traffic pollutions can damagethe aluminium fins, reducing the capacity and life expectancy of the unit.
All City Multi R410Aoutdoor units have been treated with Blue Fin
YJM-A
YGM-A YJM-A
YGM-A
33kg
Approximately 21% reduction in foot print (PUHY-P250)
Hei
ght
1710
mm
Width920mm
Depth760mm
8-12hp outdoor units
Example of lift
Weight ReductionWeight has been reduced by approximately 33kg per module.
(PUHY-P250YJM-A compared to previous YGM-A versions).
Page 144 Page 145
Easily TransportedThe unit can easily be transported, even into inaccessible buildings. Narrow space between buildings often makes it difficult to use acrane, City Multi helps to overcome this due to its design.
The downsized outdoor unitcan also be transported through an 800mm wide lift door, making access to rooftops easier.
The designof City Multi
outdoor units makesinstallation
easy
R410A Pipe SizingAs R410A has a higher specific heat capacity than R22, the pipework is smaller.
This means the pipe itself is cheaper, easierto install and less riser space is requiredwithin the building.
Example of a 10hp model
Heating Operation Range:Standard & High COP air cooled unitsAt low ambient temperatures the guaranteed operating
range in heating is minus 20ºCOperating range in cooling is from an outdoor temperature of -5ºC.
Back-Up & RotateBack-up - In the case of one module breakingdown, the remaining units will perform back-upoperation until the faulty unit is repaired.
Rotation - In the case of two or three modules,the load will be balanced between the units overtime, extending the life of the system.
Page 146
Outdoor Temperature (ºC)
Page 147
High Performance HeatingThe new High Performance Heating mode isavailable on all YJM-A / YJM-B models andachieves an excellent heating performance atlow outdoor air temperatures, making it idealfor the UK climate.
Activated by dip switch on the outdoor unit, COP priorityor high performance heating modes can be selected. Highperformance heating mode is pre-selected on all YJM-Aoutdoor models.
In high performance heating mode, the control strategy is alteredto allow the compressor to maintain a higher frequency atlower ambient temperatures, resulting in full nominal capacitydown to -5°C on many models. What this means is that asmaller outdoor unit can be installed to produce the samecapacity as a larger one would if it was in COP priority mode,therefore saving on both cost and space.
In COP priority mode, control is reverted back to normal and the power consumption lowered. However, even at -5°Cthe COP is kept high.
Note: This is only a representation. Actual data varies depending on individual outdoor unit.
-20 -15 -10 -5 0 5 10 15
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
Ambient Temperature
Rat
io o
f Hea
ting
Cap
acity
11% capacity increase
High Performance Heating Mode
COP Priority Mode
Outdoor Temperature (ºC)
Hea
ting
Cap
acity
req
uire
d (k
W)
5.00
4.50
4.00
3.50
3.00
2.50
2.00
6.00
5.50
121086420-2-47.5
12.5
17.5
22.5
27.5
32.5
37.5
CO
P
Heating Capacity Requirement (kW) COP (P250 High Performance Heating Mode)
Note: This is only a representation of a PUHY-RP250 over the winter period. Actual data varies depending on individual outdoor unit.
Seasonal Efficiency The ideal application for high performance heating mode iswith a heating only system, or a system sized for a heating loadas this is where substantial savings can be achieved. A system isdesigned for full load at a fixed design temperature, forexample -3°C WB as in the example below.
In this example, as the ambient temperature rises, the heatingload decreases and the inverter is able to ramp the heat pumpdown, thus increasing efficiency.
� Under the scheme, all businesses liable for UK corporation tax are able to claim an enhanced capital allowance on any qualifying expenditure (regardless of size and location of business or whether in the industrial orcommercial sector).
� Businesses can offset the full cost of specific technologies (such as City Multi)against taxable profits of the period of the investment.
� In order to qualify for this scheme, technology has to meet the energy saving criteria as published in theEnergy Technology Criteria List. City Multi fully meets this criteria in its drive for energy efficiency.
� Only investment in new and unused plant and machinery qualify.
For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.
The Key Features of the Scheme:
Mitsubishi Electric produces a series of comprehensive CPD approved IndustryInformation Guides, designed to enhancethe knowledge of our customers and providea view of all the key issues facing our
industry today.
All our information guides are availableto download from our website:
www.mitsubishielectric.co.uk/aircon
City Multi ExceedsCurrent Demands for Eff iciencyThe need for energy efficiency is paramount and is determined by legislation and regulation.In 2009 the Climate Change Act was updated, putting a greater emphasis on reducing energyuse and thus CO2 emissions.
2010 also saw big changes with the introduction of the CRC Energy Efficiency Scheme (formerly the Carbon Reduction Commitment),which is a mandatory emissions trading scheme. It is central to the UK’s strategy for improving energy efficiency and reducing CO2
emissions. The scheme will affect around 5000 organisations, creating a financial incentive to actively reduce their CO2 emissionsacross their business as a whole.
In addition to these, the newly revised Part L of the building regulations outlines the need to reduce carbon emissions by 25% onaggregate over a Part L 2006 building. These regulations show the positive steps being taken towards achieving highly energy efficient,zero carbon new buildings. Mitsubishi Electric’s range of energy efficient heating, cooling, ventilation and controls products all help tocomply with these regulations and schemes.
To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). Qualifyingproducts on the Energy Technology Product List include heat pumps for space heating. The City Multi range has been designed toensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.
Page 148 Page 149
Enhanced
Capital Allowance
Scheme
(ECA)
n nnnn n n n n n n n n n n
n n n n n n n n n n n
A Wide Choice of Models
The model line up
The YJM-A air sourced outdoor models are modular in design and as such differing combinations of themcan be connected together to create the required outdoor unit size needed for a particular application.The new YJM-A models also now make use of an extra large single module.
Both the Y and R2 Series come in Standard (-P) and High COP (-EP) versions. In addition, the standard versions allowfor space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.
Series
Y
Size
Model Name
PUHY-P
PUHY-EP
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp
nn n n n n n n n n n n n n n n n n n n n n
n n n n n n n n n n n n n n
R2 PURY-P
PURY-EP
Y Series (10hp) PUHY-EP YJM-A
10hp PUHY-EP250 YJM-A
Y Series (12hp) PUHY-EP YJM-A
12hp PUHY-EP300 YJM-A
Y Series (16hp) PUHY-EP YSJM-A
16hp PUHY-EP400 YSJM-A
Y Series (18hp) PUHY-EP YSJM-A
18hp PUHY-EP450 YSJM-A
Y Series (20hp) PUHY-EP YSJM-A
20hp PUHY-EP500 YSJM-A
Y Series (22hp) PUHY-EP YSJM-A
22hp PUHY-EP550 YSJM-A
R2 Series (8-12hp) PURY-P YJM-A
8hp PURY-P200 YJM-A
10hp PURY-P250 YJM-A
12hp PURY-P300 YJM-A
R2 Series (14-16hp) PURY-P YJM-A
14hp PURY-P350 YJM-A
16hp PURY-P400 YJM-A
R2 Series (18hp) PURY-P YJM-A
18hp PURY-P450 YJM-A
R2 Series (18-24hp) PURY-P YSJM-A(1)
18hp PURY-P450 YSJM-A120hp PURY-P500 YSJM-A22hp PURY-P550 YSJM-A24hp PURY-P600 YSJM-A
R2 Series (8hp) PURY-EP YJM-A
8hp PURY-EP200 YJM-A
R2 Series (10-12hp) PURY-EP YJM-A
10hp PURY-EP250 YJM-A
12hp PURY-EP300YJM-A
R2 Series (14hp) PURY-EP YJM-A
14hp PURY-EP350 YJM-A
R2 Series (16hp) PURY-EP YSJM-A
16hp PURY-EP400 YSJM-A
Y Series (26hp) PUHY-EP YSJM-A
26hp PUHY-EP650 YSJM-A
Y Series (28hp) PUHY-EP YSJM-A
28hp PUHY-EP700 YSJM-A
Y Series (30hp) PUHY-EP YSJM-A
30hp PUHY-EP750 YSJM-A
Y Series (32hp) PUHY-EP YSJM-A
32hp PUHY-EP800 YSJM-A
Y Series (34hp) PUHY-EP YSJM-A
34hp PUHY-EP850 YSJM-A
Y Series (36hp) PUHY-EP YSJM-A
36hp PUHY-EP900 YSJM-A
R2 Series (26-28hp) PURY-P YSJM-A
26hp PURY-P650 YSJM-A
28hp PURY-P700YSJM-A
R2 Series (30-32hp) PURY-P YSJM-A
30hp PURY-P750 YSJM-A
32hp PURY-P800YSJM-A
R2 Series (34hp) PURY-P YSJM-A
34hp PURY-P850 YSJM-A
R2 Series (36hp) PURY-P YSJM-A
36hp PURY-P900 YSJM-A
R2 Series (18-20hp) PURY-EPYSJM-A
18hp PURY-EP450YSJM-A
20hp PURY-EP500YSJM-A
R2 Series (22-24hp) PURY-EP YSJM-A
22hp PURY-EP550YSJM-A
24hp PURY-EP600YSJM-A
R2 Series (26hp) PURY-EP YSJM-A
26hp PURY-EP650YSJM-A
R2 Series (28hp) PURY-EP YSJM-A
28hp PURY-EP700YSJM-A
Y Series (8-12hp) PUHY-P YJM-A
Y Series (14-16hp) PUHY-P YJM-A
14hp PUHY-P350 YJM-A
16hp PUHY-P400 YJM-A
Y Series (18hp) PUHY-P YJM-A
18hp PUHY-P450 YJM-A
Y Series (20-22hp) PUHY-P YSJM-A
20hp PUHY-P500 YSJM-A
22hp PUHY-P550 YSJM-A
Y Series (24-26hp) PUHY-P YSJM-A
24hp PUHY-P600 YSJM-A
26hp PUHY-P650 YSJM-A
Y Series (28-30hp) PUHY-P YSJM-A
28hp PUHY-P700 YSJM-A
30hp PUHY-P750 YSJM-A
Y Series (32-34hp) PUHY-P YSJM-A
32hp PUHY-P800 YSJM-A
34hp PUHY-P850 YSJM-A
Y Series (8hp) PUHY-EP YJM-A
8hp PUHY-EP200 YJM-A
Y Series (36hp) PUHY-P YSJM-A
36hp PUHY-P900 YSJM-A
Y Series (38-40hp) PUHY-P YSJM-A
38hp PUHY-P950 YSJM-A
40hp PUHY-P1000 YSJM-A
Y Series (42hp) PUHY-P YSJM-A
42hp PUHY-P1050 YSJM-A
Y Series (44hp) PUHY-P YSJM-A
44hp PUHY-P1100 YSJM-A
Y Series (46-48hp) PUHY-P YSJM-A
46hp PUHY-P1150 YSJM-A
48hp PUHY-P1200 YSJM-A
Y Series (50hp) PUHY-P YSJM-A
50hp PUHY-P1250 YSJM-A
Y Series (24hp) PUHY-EP YSJM-A
24hp PUHY-EP600 YSJM-A
Y Series Heat Pump - Standard Version
Y Series Heat Pump - High COP Version
R2 Series Heat Recovery - Standard Version
R2 Series Heat Recovery - High COP Version
8hp PUHY-P200 YJM-A
10hp PUHY-P250 YJM-A
12hp PUHY-P300 YJM-A
Page 150 Page 151
Y Series (4/5/6hp)
PUMY-P100-140V/YHMB
63(7.1kW)
80(9.0kW)
100(11.2kW)
125(14.0kW)
140(16.0kW)
200(22.4kW)
140kW Cooling Capacity
Y / R2 Series
PURY-RP200-300YJM-B
Page 153
Y / R2 Series
PUH/RY-P200-300YJM-APUH/RY-EP200YJM-A
11.2kW Cooling Capacity
Model / Size
PLFY-P-VBM-E
PLFY-P-VCM-E2
PLFY-P-VLMD-E
PMFY-P-VBM-E
PEFY-P-VMS1-E
PEFY-P-VMA-E
PEFY-P-VMH-E
PCFY-P-VKM-E
PKFY-P-VBM/VHM/VKM-E
PFFY-P-VLRM-E
PFFY-P-VLRMM-E
PFFY-P-VLEM-E
PFFY-P-VKM-E
GUF-RD3
PWFY-P
15(1.7kW)
20(2.2kW)
25(2.8kW)
32(3.6kW)
40(4.5kW)
50(5.6kW)
Page 152
Indoor Units
250(28.0kW)
City Multi Product Range OverviewOutdoor Units
Y Series Zubadan
PQ(H/R)Y-P200-300YHM-A
WY / WR2 Series
PUHY-HP200/250YHM-APUH/RY-P350/400YJM-A
PUHY-EP250YJM-APURY-EP250/300YJM-A
Y / R2 Series
PUH/RY-P450YJM-APUHY-EP300YJM-APURY-EP350YJM-A
Y Series Replace Multi
PUHY-RP200-350YJM-B
R2 Series Replace Multi
Y Series (4-6hp)Heat Pump, Outdoor Unit
Y Series Standard (8-18hp)Heat Pump, Outdoor Unit
Y Series Standard (20-30hp)Heat Pump, Outdoor Unit
Y Series Standard (32-36hp)Heat Pump, Outdoor Unit
Y Series Standard (38-44hp)Heat Pump, Outdoor Unit
Y Series Standard (46-50hp)Heat Pump, Outdoor Unit
Y Series High COP (8-18hp)Heat Pump, Outdoor Unit
Y Series High COP (20-24hp)Heat Pump, Outdoor Unit
Y Series High COP (26-30hp)Heat Pump, Outdoor Unit
Y Series High COP (32-36hp)Heat Pump, Outdoor Unit
Y Series Zubadan (8-20hp)Heat Pump, Outdoor Unit
Y Series Replace Multi (8-26hp)Heat Pump, Outdoor Unit
Y Series Replace Multi (28-36hp)Heat Pump, Outdoor Unit
WY Series (8-24hp)Heat Pump, Water Cooled Condensing Unit
WY Series (26-36hp)Heat Pump, Water Cooled Condensing Unit
R2 Series Standard (8-18hp)Heat Recovery, Outdoor Unit
R2 Series Standard (18-28hp)Heat Recovery, Outdoor Unit
R2 Series Standard (30-36hp)Heat Recovery, Outdoor Unit
R2 Series High COP (8-20hp)Heat Recovery, Outdoor Unit
R2 Series High COP (22-28hp)Heat Recovery, Outdoor Unit
R2 SeriesPiping Restrictions
R2 Series Replace Multi (8-12hp)Heat Recovery, Outdoor Unit
WR2 Series (8-24hp)Heat Recovery, Water Cooled Condensing Unit
PFD-P-VM-EHeat Pump, Close Control System
PLFY-P-VBM-E2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P-VCM-E2600x600 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P-VLMD-E2-Way Blow Ceiling Cassette Indoor Unit
PMFY-P-VBM-E1-Way Blow Ceiling Cassette Indoor Unit
PEFY-P-VMS1-EUltra Thin Ceiling Concealed Ducted Indoor Unit
PEFY-P-VMA-ECeiling Concealed Ducted Indoor Unit
PEFY-P-VMH-EHigh Static Pressure Ceiling Concealed Ducted Indoor Unit
PCFY-P-VKM-ECeiling Suspended Indoor Unit
PKFY-P-VBM/VHM/VKM-EWall Mounted Indoor Unit
PFFY-P-VLRM-EFloor Standing Concealed Indoor Unit
PFFY-P-VLRMM-EFloor Standing Concealed Indoor Unit
PFFY-P-VLEM-EFloor Standing Exposed Indoor Unit
PFFY-P-VKM-EFloor Standing Exposed Indoor Unit
GUF-RD3Lossnay Outdoor Air Processing Unit
PWFY-PVRF Heat Pump Boiler
VRF PHV DXEVRF Heat Pump Air Curtain
VRF PHV NTSensible Cooling, Chilled Water Indoor Unit
BC Controllers
Water System Connection Box (WCB)
Air Handling Unit Controllers
Accessories / Optional Extras
156
158
160
162
164
166
168
170
172
174
176
178
180
182
184
186
188
190
192
194
196
198
200
202
204
206
208
210
212
214
216
218
220
222
224
226
228
230
232
236
238
240
242
243
234
Page 155Page 154
Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings.Up to 50 indoor units can be connected to a single outdoor unit, offering thesophistication, control and energyefficiency demanded today.
The energy efficient
City MultiVRF range
Simple technologyat its best
Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
For further information please go to www.eca.gov.uk
Contents
Upper View >
Side View > Front View >
PUMY-P100-140VHMB/YHMB
Cit
y M
ult
iRange
Y S
erie
s (4-6hp)
Dimensions
Page 157
Heat Pump Outdoor Unit
Y Series (4-6hp)
Y SERIES OUTDOOR UNITS 4-6hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
COP / EER (nominal)
Max no. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
PIPE SIZE mm(in) Gas
Liquid
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
GUARANTEED OPERATING RANGE Cooling
Heating
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
PUMY-P100VHMB
12.5
11.2
10.4
10.3
3.66
3.34
3.27
2.84
3.42 / 3.35
8
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
49
129
950
330+30
1350
220-240v, 50Hz
Single
5
15.5
14.1
-5ºC ~ 46ºC
-15ºC ~ 15ºC
32
3
PUMY-P125VHMB
16.0
14.0
13.3
12.9
4.33
4.32
3.85
3.66
3.69 / 3.24
10
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
50
129
950
330+30
1350
220-240v, 50Hz
Single
5
18.3
18.3
-5ºC ~ 46ºC
-15ºC ~ 15ºC
32
3
PUMY-P140VHMB
18.0
15.5
14.9
14.3
5.58
5.35
4.99
4.53
3.23 / 2.90
12
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
51
129
950
330+30
1350
220-240v, 50Hz
Single
5
23.6
22.7
-5ºC ~ 46ºC
-15ºC ~ 15ºC
32
3
PUMY-P100-140VHMB/YHMB Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
120m max
80m max
30m max
50m max (20m max if outdoor installed below)
12m max
Optional Parts
Model Name Description
CMY-Y62-G-E Branch Pipe (2 Branch)
PUMY-P100YHMB
12.5
11.2
10.4
10.3
3.63
3.30
3.23
2.81
3.44 / 3.39
8
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
49
142
950
330+30
1350
380-415v, 50Hz
3
5
5.32
4.84
-5ºC ~ 46ºC
-15ºC ~ 15ºC
16
4 + earth
PUMY-P125YHMB
16.0
14.0
13.3
12.9
4.29
4.27
3.82
3.63
3.73 / 3.28
10
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
50
142
950
330+30
1350
380-415v, 50Hz
3
5
6.29
6.26
-5ºC ~ 46ºC
-15ºC ~ 15ºC
16
4 + earth
PUMY-P140YHMB
18.0
15.5
14.9
14.3
5.32
5.32
4.73
4.52
3.38 / 2.91
12
50-130% OU Capacity
100
15.88 (5/8”)
9.52 (3/8”)
51
142
950
330+30
1350
380-415v, 50Hz
3
5
7.8
7.8
-5ºC ~ 46ºC
-15ºC ~ 15ºC
16
4 + earth
Technical Information
The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 12 indoor units to be connected to a single outdoor unit, using the standard branch/header pipeworksystem proven in the larger models. Utilising the latest Mitsubishi Electric inverter technology, the system is fully controllable with all City Multi controllers or linked to third party BEMS.
� A two core non-polar transmission line allows for simple installation of up to twelve indoor units now
� Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control
� The condensing unit is extremely slimline which allows easy location and application of the system
� Single or three phase power supply
� Anti-Corrosion blue and flat fin technology
Page 156
PUHY-P200, 250, 300YJM-A
PUHY-P350, 400YJM-A
Upper View >
Cit
y M
ult
iRange
Y S
erie
s St
andar
d (8-18hp)
Dimensions
Front View >Side View >
Page 159
Upper View >Front View >Side View >
Upper View >Front View >Side View >
PUHY-P450YJM-A
Heat Pump Outdoor Unit
Y SERIES STANDARD OUTDOOR UNITS 8-18hp
Y Series Standard (8-18hp)
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-P200YJM-A
25.0
22.4
25.0
22.8
21.3
5.84
5.62
7.36
5.78
3.23
4.28 / 3.98
17
170
56
190
920
760
1710
380-415v, 50Hz
3
8
9.0
8.6
20
4 + earth
PUHY-P250YJM-A
31.5
28.0
31.5
28.7
26.6
7.34
7.40
9.25
7.27
4.26
4.29 / 3.78
21
170
58
200
920
760
1710
380-415v, 50Hz
3
8
11.3
11.4
20
4 + earth
PUHY-P300YJM-A
37.5
33.5
35.6
32.3
31.5
9.25
9.00
12.40
8.97
5.81
4.05 / 3.72
26
170
59
215
920
760
1710
380-415v, 50Hz
3
8
14.2
13.9
25
4 + earth
PUHY-P350YJM-A
45.0
40.0
42.8
38.7
37.6
11.19
11.01
14.99
10.85
7.10
4.02 / 3.63
30
210
60
250
1220
760
1710
380-415v, 50Hz
3
8
17.2
17.0
32
4 + earth
PUHY-P400YJM-A
50.0
45.0
47.5
43.0
42.3
12.82
13.11
17.18
12.44
8.46
3.90 / 3.43
34
210
61
250
1220
760
1710
380-415v, 50Hz
3
8
19.8
20.2
32
4 + earth
PUHY-P450YJM-A
56.0
50.0
50.7
48.7
46.0
14.62
15.47
16.67
13.30
9.75
3.83 / 3.23
39
370
62
290
1750
760
1710
380-415v, 50Hz
3
8
22.5
23.9
40
4 + earth
PUHY-P200-450YJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeoverfrom cooling to heating to ensure that a constant indoor climate is maintained.
� Wrap around coil for improved energy efficiency
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 158
PUHY-P500, 550YSJM-A
PUHY-P600, 650YSJM-A
Cit
y M
ult
iRange
Y S
erie
s St
andar
d (20-30hp)
Dimensions
Side View > Front View >
Side View > Front View >
Side View > Front View >
PUHY-P700, 750YSJM-A
Page 161
PUHY-P500-750YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Heat Pump Outdoor Unit
Y Series Standard (20-30hp)
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Wrap around coil for improved energy efficiency
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 160
Y SERIES STANDARD OUTDOOR UNITS 20-30hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-P500YSJM-A
63.0
56.0
57.0
54.8
51.5
15.03
15.38
17.13
13.68
9.69
4.19 / 3.64
43
170 / 170
61
200 + 200
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
23.2
23.7
20 / 20
4 + earth
PUHY-P550YSJM-A
69.0
63.0
62.4
60.0
58.0
16.87
17.16
19.23
15.35
10.81
4.09 / 3.67
47
170 / 170
61.5
215 + 200
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
26.0
26.5
25 / 20
4 + earth
PUHY-P600YSJM-A
76.5
69.0
69.2
66.6
63.5
18.88
18.75
21.52
17.18
11.81
4.05 / 3.68
50
210 / 170
62
250 + 200
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
29.1
28.9
32 / 20
4 + earth
PUHY-P650YSJM-A
81.5
73.0
73.8
70.9
67.2
20.47
20.39
23.34
18.63
12.85
3.98 / 3.58
50
210 / 170
62.5
250 + 215
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
31.6
31.5
32 / 25
4 + earth
PUHY-P700YSJM-A
88.0
80.0
88.0
76.6
73.6
22.27
22.47
28.06
20.71
14.49
3.95 / 3.56
50
210 / 210
63
250 + 250
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
34.4
34.7
32 / 32
4 + earth
PUHY-P750YSJM-A
95.0
85.0
95.0
82.7
78.2
24.67
24.70
31.08
22.94
15.93
3.85 / 3.44
50
210 / 210
63.5
250 + 250
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
38.1
38.1
32 / 32
4 + earth
PUHY-P800, 850YSJM-A
PUHY-P900YSJM-A
Cit
y M
ult
iRange
Y S
erie
s St
andar
d (32-36hp)
Dimensions
Page 163
Side View > Front View >
Side View > Front View >
PUHY-P800-900YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Heat Pump Outdoor Unit
Y Series Standard (32-36hp)
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Wrap around coil for improved energy efficiency
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 162
Y SERIES STANDARD OUTDOOR UNITS 32-36hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-P800YSJM-A
100.0
90.0
100.0
87.0
82.8
25.70
27.10
32.38
23.90
17.48
3.89 / 3.32
50
370 / 210
64
290 + 250
1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
39.7
41.8
40 / 32
4 + earth
PUHY-P850YSJM-A
108.0
96.0
102.6
95.0
88.3
28.42
29.62
37.80
26.15
18.07
3.80 / 3.24
50
370 / 210
64.5
290 + 250
1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
43.9
45.7
40 / 32
4 + earth
PUHY-P900YSJM-A
113.0
101.0
107.4
99.4
92.9
30.05
32.06
39.97
27.65
19.56
3.76 / 3.15
50
370 / 370
65
290 + 290
1750 + 1750
760
1710
380-415v, 50Hz
3
8 / 8
46.4
49.5
40 / 40
4 + earth
PUHY-P950, 1000YSJM-A
PUHY-P1050YSJM-A
Cit
y M
ult
iRange
Y S
erie
s St
andar
d (38-44hp)
Dimensions
Side View > Front View >
Side View > Front View >
Side View > Front View >
PUHY-P1100YSJM-A
Page 165
PUHY-P950-1100YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Heat Pump Outdoor Unit
Y Series Standard (38-44hp)
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Wrap around coil for improved energy efficiency
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 164
Y SERIES STANDARD OUTDOOR UNITS 38-44hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-P950YSJM-A
119.5
108.0
113.5
105.2
99.4
30.02
30.50
39.93
27.62
18.61
3.98 / 3.54
50
210 / 170 / 170
64.5
250 + 215 + 200
1220 + 920 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
46.4
47.1
32 / 25 / 20
4 + earth
PUHY-P1000YSJM-A
127.0
113.0
120.7
111.8
104.0
33.15
32.10
44.09
30.50
19.58
3.83 / 3.52
50
210 / 170 / 170
64.5
250 + 215 + 215
1220 + 920 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
51.2
49.6
32 / 25 / 25
4 + earth
PUHY-P1050YSJM-A
132.0
118.0
125.4
116.2
108.6
34.10
33.81
45.35
31.37
20.62
3.87 / 3.49
50
210 / 210 / 170
65
250 + 250 + 215
1220 + 1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
52.7
52.2
32 / 32 / 25
4 + earth
PUHY-P1100YSJM-A
140.0
124.0
133.0
123.2
114.1
36.08
35.73
47.99
33.19
21.80
3.88 / 3.47
50
210 / 210 / 210
65
250 + 250 + 250
1220 + 1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8 / 8
55.7
55.2
32 / 32 / 32
4 + earth
PUHY-P1150, 1200YSJM-A
PUHY-P1250YSJM-A
Cit
y M
ult
iRange
Y S
erie
s St
andar
d (46-50hp)
Dimensions
Side View > Front View >
Side View > Front View >
Page 167
PUHY-P1150-1250YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Heat Pump Outdoor Unit
Y Series Standard (46-50hp)
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Wrap around coil for improved energy efficiency
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 166
Y SERIES STANDARD OUTDOOR UNITS 46-50hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-P1150YSJM-A
145.0
130.0
137.8
127.6
119.6
37.27
38.34
49.57
34.29
23.39
3.89 / 3.39
50
370 / 210 / 210
65.5
290 + 250 + 250
1750 + 1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8 / 8
57.6
59.2
40 / 32 / 32
4 + earth
PUHY-P1200YSJM-A
150.0
136.0
142.5
132.0
125.1
39.26
40.84
52.22
36.12
24.91
3.82 / 3.33
50
370 / 210 / 210
66
290 + 250 + 250
1750 + 1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8 / 8
60.6
63.1
40 / 32 / 32
4 + earth
PUHY-P1250YSJM-A
156.5
140.0
148.7
137.7
128.8
40.86
42.94
54.34
37.59
26.19
3.83 / 3.26
50
370 / 370 / 210
66
290 + 290 + 250
1750 + 1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8 / 8
63.1
66.3
40 / 40 / 32
4 + earth
PUHY-EP400YSJM-A
Side View > Front View >
PUHY-EP200, 250, 300YJM-A
PUHY-EP450YSJM-A
Cit
y M
ult
iRange
Y S
erie
s H
igh C
OP (8-18hp)
Dimensions
Side View > Front View >
PUHY-EP200YJM-A schematic is the same as PUHY-P200, 250, 300YJM-A on page 158
PUHY-EP250YJM-A schematic is the same as PUHY-P350, 400YJM-A on page 158
PUHY-EP300YJM-A schematic is the same as PUHY-P450YJM-A on page 158
Page 169
Heat Pump Outdoor Unit
Y Series High COP (8-18hp)
PUHY-EP200-450Y(S)JM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout,with the choice of either Branch Pipe or Header Pipe feeds to indoor units,with manual changeover from cooling to heating to ensure that a constantindoor climate is maintained.
� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Y SERIES HIGH COP OUTDOOR UNITS 8-18hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-EP200YJM-A
25.0
22.4
25.0
22.8
21.3
5.54
5.09
6.98
5.48
2.93
4.51 / 4.40
17
170
57
200
920
760
1710
380-415v, 50Hz
3
8
8.5
7.8
20
4 + earth
PUHY-EP250YJM-A
31.5
28.0
31.5
28.7
26.6
7.15
6.73
9.01
7.08
3.87
4.40 / 4.16
21
210
60
250
1220
760
1710
380-415v, 50Hz
3
8
11.0
10.4
20
4 + earth
Page 168
PUHY-EP300YJM-A
37.5
33.5
35.6
32.3
31.5
8.37
8.03
11.22
8.12
5.18
4.48 / 4.17
26
370
61
290
1750
760
1710
380-415v, 50Hz
3
8
12.9
12.4
25
4 + earth
PUHY-EP400YSJM-A
50.0
45.0
47.5
43.0
42.3
11.41
10.34
15.29
11.07
6.67
4.38 / 4.35
35
170 / 170
60
200 + 200
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
17.6
15.9
20 / 20
4 + earth
PUHY-EP450YSJM-A
56.0
50.0
50.7
48.7
46.0
12.90
11.87
14.71
11.74
7.48
4.34 / 4.21
39
210 / 170
62
250 + 200
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
19.9
18.3
20 / 20
4 + earth
PUHY-EP500YSJM-A
PUHY-EP550YSJM-A
Cit
y M
ult
iRange
Y S
erie
s H
igh C
OP (20-24hp)
Dimensions
PUHY-EP600YSJM-A
Page 171
Side View > Front View >
Side View > Front View >
Side View > Front View >
Heat Pump Outdoor Unit
Y Series High COP (20-24hp)
PUHY-EP500-600YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manualchangeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation isachievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Y SERIES HIGH COP OUTDOOR UNITS 20-24hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
Page 170
PUHY-EP500YSJM-A
63.0
56.0
57.0
54.8
51.5
14.28
13.30
16.28
12.99
8.38
4.41 / 4.21
43
370 / 170
62.5
290 + 200
1750 + 920
760
1710
380-415v, 50Hz
3
8 / 8
22.0
20.5
25 / 20
4 + earth
PUHY-EP550YSJM-A
69.0
63.0
62.4
60.0
58.0
15.78
15.36
17.99
14.36
9.68
4.37 / 4.10
47
370 / 210
63.5
290 + 250
1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
24.3
23.7
25 / 20
4 + earth
PUHY-EP600YSJM-A
76.5
69.0
69.2
66.6
63.5
17.30
16.82
19.72
15.74
10.60
4.42 / 4.10
50
370 / 370
64
290 + 290
1750 + 1750
760
1710
380-415v, 50Hz
3
8 / 8
26.7
26.0
25 / 25
4 + earth
Cit
y M
ult
iRange
Y S
erie
s H
igh C
OP (26-30hp)
PUHY-EP650YSJM-A
PUHY-EP700YSJM-A
Dimensions
Side View > Front View >
Side View > Front View >
Side View > Front View >
PUHY-EP750YSJM-A
Page 173
Heat Pump Outdoor Unit
Y Series High COP (26-30hp)
PUHY-EP650-750YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 172
Y SERIES HIGH COP OUTDOOR UNITS 26-30hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-EP650YSJM-A
81.5
73.0
73.8
70.9
67.2
18.56
17.46
21.16
16.89
11.00
4.39 / 4.18
50
210 / 170 / 170
63
250 + 200 + 200
1220 + 920 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
28.6
26.9
20 / 20 / 20
4 + earth
PUHY-EP700YSJM-A
88.0
80.0
88.0
76.6
73.6
20.00
19.13
25.20
18.60
12.34
4.40 / 4.18
50
370 / 170 / 170
63.5
290 + 200 + 200
1750 + 920 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
30.9
29.5
25 / 20 / 20
4 + earth
PUHY-EP750YSJM-A
95.0
85.0
95.0
82.7
78.2
21.93
20.43
27.63
20.39
13.18
4.33 / 4.16
50
370 / 210 / 170
64.5
290 + 250 + 200
1750 + 1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
33.8
31.5
25 / 20 / 20
4 + earth
Cit
y M
ult
iRange
Y S
erie
s H
igh C
OP (32-36hp)
PUHY-EP800YSJM-A
PUHY-EP850YSJM-A
Dimensions
PUHY-EP900YSJM-A
Page 175
Side View > Front View >
Side View > Front View >
Side View > Front View >
PUHY-EP800YSJM-A
100.0
90.0
100.0
87.0
82.8
22.77
21.63
28.69
21.18
13.95
4.39 / 4.16
50
370 / 370 / 170
65
290 + 290 + 200
1750 + 1750 + 920
760
1710
380-415v, 50Hz
3
8 / 8 / 8
35.1
33.4
25 / 25 / 20
4 + earth
PUHY-EP850YSJM-A
108.0
96.0
102.6
95.0
88.3
24.65
23.58
32.78
22.68
14.38
4.38 / 4.07
50
370 / 370 / 210
65.5
290 + 290 + 250
1750 + 1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8 / 8
38.1
36.4
25 / 25 / 20
4 + earth
PUHY-EP900YSJM-A
113.0
101.0
107.4
99.4
92.9
25.50
24.81
33.92
23.46
15.13
4.43 / 4.07
50
370 / 370 / 370
66
290 + 290 + 290
1750 +1750 + 1750
760
1710
380-415v, 50Hz
3
8 / 8 / 8
39.4
38.3
25 / 25 / 25
4 + earth
Heat Pump Outdoor Unit
Y Series High COP (32-36hp)
PUHY-EP800-900YSJM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Improved for even higher efficiency
Technical Information
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil
� Choice of Branch Pipe or Header Pipe feeds to indoor units
� Energy-saving inverter driven outdoor compressor units with very low start currents
� No requirement for plant rooms or bulky service shafts
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m, with a total system pipe length of 1000m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 174
Y SERIES HIGH COP OUTDOOR UNITS 32-36hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-HP200, 250YHM-A
PUHY-HP400, 500YSHM-A
Upper View >
Cit
y M
ult
iRange
Y S
erie
s Z
ubad
an (8-20hp)
Dimensions
Upper View >
Front View >Side View >
Page 177
Side View > Front View >
PUHY-HP200-500Y(S)HM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
300m max
150m max
40m max
50m max (40m max if outdoor installed below)
15m max
Heat Pump Outdoor Unit
Y SERIES ZUBADAN OUTDOOR UNITS 8-20hp
Y Series Zubadan (8-20hp)
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
OPERATING RANGE (Outdoor temp ºC) Heating
PUHY-HP200YHM-A
25.0
22.4
28.0
19.9
6.52
6.40
11.02
4.99
3.83 / 3.50
17
225
56
220
920
760
1710
380-415v, 50Hz
3
8
10.0
9.8
32
4 + earth
-25 - 15.5ºC
PUHY-HP250YHM-A
31.5
28.0
35.3
24.9
8.94
9.06
15.11
7.07
3.52 / 3.09
21
225
57
220
920
760
1710
380-415v, 50Hz
3
8
13.8
14.0
32
4 + earth
-25 - 15.5ºC
PUHY-HP400YSHM-A
50.0
45.0
56.0
40.1
13.35
12.86
22.56
10.03
3.74 / 3.49
34
225 / 225
59
220 + 220
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
20.6
19.8
32 / 32
4 + earth
-25 - 15.5ºC
PUHY-HP500YSHM-A
63.0
56.0
70.6
49.8
18.04
18.16
30.49
14.16
3.49 / 3.08
43
225 / 225
60
220 + 220
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
27.8
28.0
32 / 32
4 + earth
-25 - 15.5ºC
Zubadan sets a new standard in performance
Technical Information
The new City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.
� Stable Heating Performance - Full heating capacity at -15°C- a 40% capacity improvement over the standard YJM-A model
� Expanded Heating Operation - Will work effectively even whenthe outdoor ambient air temperature is -25°C
� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan modelshave reduced defrost times and can provide continuous heating for up to 250 mins
� Quick Start-Up - Full heating capacity is achieved in about 20 mins,improving comfort levels
� Energy-saving inverter driven outdoor compressor units with very low start currents
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants
Page 176
PUHY-RP200, 250, 300, 350YJM-B Upper View >
Cit
y M
ult
iRange
Y S
erie
s R
epla
ce M
ulti (8-26hp)
Dimensions
Front View >Side View >
PUHY-RP400, 450, 500, 550, 600, 650YSJM-B
Upper View >
Side View > Front View >
Page 179
Heat Pump Outdoor Unit
Y Series Replace Multi (8-26hp)
PUHY-RP200-650Y(S)JM-B Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
300m max (250m for size 600-650)
120m max
40m max
50m max (40m max if outdoor installed below)
15m max
Enables the replacement of VRF systems, whilst utilisingexisting R22 / R407c pipework.
Technical Information
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturingrefurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market.
Replace Multi will clean the existing pipework during commissioning, removing any depositsand R22 mineral oil that would have ordinarily meant that new pipework would have beencalled for. The implications of this are significant savings on cost and time, whilst alsominimising any potential disruption.
n Efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials
n Increased energy efficiency - up to 105% more efficient than an old Mitsubishi Electric R22 system (size 200)
n Reduced installation costs of up to 55%
n Reduced CO2 emissions and running cost savings of up to 45%
n Reduced installation time with minimised disruption
n Ability to replace many non Mitsubishi Electric systems
n High Performance Heating Mode for low ambient conditions
Page 178
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - HRC (A)
MAINS CABLE No. Cores
PUHY-RP200YJM-B
25.0
22.4
25.0
22.8
19.9
5.69
5.68
7.34
5.63
4.43
4.39 / 3.94
17
185
56
230
920
760
1710
380-415v, 50Hz
3
8
8.7
8.7
20
4 + earth
PUHY-RP250YJM-B
31.5
28.0
31.5
28.7
24.9
7.22
7.62
9.31
7.15
5.94
4.36 / 3.67
21
185
57
255
920
760
1710
380-415v, 50Hz
3
8
12.1
12.7
20
4 + earth
PUHY-RP300YJM-B
37.5
33.5
36.0
32.6
31.5
9.42
8.98
12.43
9.14
7.36
3.98 / 3.73
26
185
59
255
920
760
1710
380-415v, 50Hz
3
8
15.2
14.4
25
4 + earth
PUHY-RP350YJM-B
45.0
40.0
43.2
39.2
37.6
12.60
11.79
16.63
12.22
9.67
3.57 / 3.39
30
185
60
255
920
760
1710
380-415v, 50Hz
3
8
20.2
18.9
32
4 + earth
PUHY-RP400YSJM-B
50.0
45.0
48.0
43.5
42.3
11.38
11.87
14.57
11.04
9.73
4.39 / 3.79
32
185 / 185
59
230 + 230
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
17.5
18.3
20 + 20
4 + earth
PUHY-RP450YSJM-B
56.0
50.0
53.8
48.7
46.0
12.81
13.77
16.40
11.66
9.64
4.37 / 3.63
32
185 / 185
59.5
255 + 230
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
20.7
22.2
20 + 20
4 + earth
PUHY-RP500YSJM-B
63.0
56.0
60.5
54.8
51.5
14.44
15.68
18.48
13.14
10.98
4.36 / 3.57
32
185 / 185
60
255 + 255
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
24.2
26.2
20 + 20
4 + earth
PUHY-RP550YSJM-B
69.0
63.0
66.2
60.0
58.0
16.62
17.50
21.27
15.12
12.25
4.15 / 3.60
32
185 / 185
61
255 + 255
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
27.3
28.7
25 + 20
4 + earth
PUHY-RP600YSJM-B
76.5
69.0
73.4
66.6
63.5
19.22
18.59
24.60
17.49
13.01
3.98 / 3.71
32
185 / 185
62
255 + 255
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
31.1
30.8
25 + 25
4 + earth
PUHY-RP650YSJM-B
81.5
73.0
78.2
70.9
67.2
21.73
21.09
27.81
19.77
14.76
3.75 / 3.46
32
185 / 185
62.5
255 + 255
920 + 920
760
1710
380-415v, 50Hz
3
8 + 8
35.0
34.0
32 + 25
4 + earth
Y SERIES REPLACE MULTI OUTDOOR UNITS 8-26hp
PUHY-RP700, 750, 800, 850, 900YSJM-B
Cit
y M
ult
iRange
Y S
erie
s R
epla
ce M
ulti (28-36hp)
Dimensions
Upper View >
Side View > Front View >
PUHY-RP700-900YSJM-B Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
250m max
100m max
40m max
50m max (40m max if outdoor installed below)
15m max
Page 180
Y SERIES REPLACE MULTI OUTDOOR UNITS 28-36hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PUHY-RP700YSJM-B
88.0
80.0
84.5
76.6
73.6
20.13
22.22
26.57
18.72
18.66
4.37 / 3.60
32
185 / 185 / 185
61.5
255 + 255 + 230
920 + 920 + 920
760
1710
380-415v, 50Hz
3
8 + 8 + 8
33.0
36.4
20 + 20 + 20
4 + earth
PUHY-RP750YSJM-B
95.0
85.0
91.2
82.7
78.2
21.78
24.14
28.75
20.26
20.28
4.36 / 3.52
32
185 / 185 / 185
62
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
3
8 + 8 + 8
36.5
39.7
20 + 20 + 20
4 + earth
PUHY-RP800YSJM-B
100.0
90.0
96.0
87.0
82.8
23.75
25.49
31.35
22.09
21.41
4.21 / 3.53
32
185 / 185 / 185
62.5
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
3
8 + 8 + 8
39.3
42.0
25 + 20 + 20
4 + earth
PUHY-RP850YSJM-B
108.0
96.0
103.7
94.0
88.3
26.47
27.11
34.15
24.09
22.77
4.08 / 3.54
32
185 / 185 / 185
63.5
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
3
8 + 8 + 8
43.2
44.1
25 + 25 + 20
4 + earth
PUHY-RP900YSJM-B
113.0
101.0
108.5
98.3
92.9
28.39
28.29
36.62
25.83
23.76
3.98 / 3.57
32
185 / 185 / 185
64
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
3
8 + 8 + 8
45.9
45.7
25 + 25 + 25
4 + earth
Heat Pump Outdoor Unit
Y Series Replace Multi (28-36hp)
Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework.
Technical Information
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector,enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficientsystems available in the market.
Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil thatwould have ordinarily meant that new pipework would have been called for. The implications of this are significantsavings on cost and time, whilst also minimising any potential disruption.
� Tried and tested technology that’s been employed for over 5 years
� Efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials
� Reduced installation costs of up to 55%
� Reduced CO2 emissions and increased energy efficiencyresulting in running cost savings of up to 45%
� Reduced installation time with minimised disruption
� Ability to replace many non Mitsubishi Electric systems
� High Performance Heating Mode for low ambient conditions
Page 181
PQHY-P200, 250, 300YHM-A
PQHY-P400, 450, 500, 550, 600YSHM-A
Upper View >
Front View > Right Side View >
Front View >Left Side View >
Cit
y M
ult
iRange
WY
Ser
ies (8-24hp)
Dimensions
Page 183
WY SERIES HEAT SOURCE UNITS - 8-24hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1100 without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
WY Series (8-24hp)Heat Pump, Water Cooled Condensing Unit
PQHY-P200-600Y(S)HM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
300m max for sizes 200-300 / 500m max for sizes 400-600
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Technical Information
� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever
� 40% height reduction compared to previous YGM-A models
� Combining WY with waste heat energy provides unique application solutions
� Up to 50 indoor units can now be connected to each condensing unit
� Single inverter compressor
� Improved pipe run of 165m with a total system pipe length of up to 500m
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible
� Easy maintenance - front panel access to all PCB’s
� Condensing units must be situated indoors
Page 182
The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heatrecovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A airsource versions, the water cooled units now benefit from a modular design approach. A twinning kit is required fordouble combinations.
PQHY-P200YHM-A
25.0
22.4
4.12
3.92
6.06 / 5.71
17
47
195
880
550
1160
380-415v, 50Hz
3
8
6.3
6.0
20
4 + earth
PQHY-P250YHM-A
31.5
28.0
5.80
5.45
5.43 / 5.13
21
49
195
880
550
1160
380-415v, 50Hz
3
8
8.9
8.4
20
4 + earth
PQHY-P300YHM-A
37.5
33.5
8.15
7.36
4.60 / 4.55
26
50
195
880
550
1160
380-415v, 50Hz
3
8
12.5
11.3
20
4 + earth
PQHY-P400YSHM-A
50.0
45.0
8.65
8.25
5.78 / 5.45
34
50
195 + 195
880 + 880
550
1160
380-415v, 50Hz
3
8 / 8
13.3
12.7
20 / 20
4 + earth
PQHY-P450YSHM-A
56.0
50.0
10.42
9.84
5.37 / 5.08
39
51
195 + 195
880 + 880
550
1160
380-415v, 50Hz
3
8 / 8
16.1
15.2
20 / 20
4 + earth
PQHY-P500YSHM-A
63.0
56.0
12.06
11.45
5.22 / 4.89
43
52
195 + 195
880 + 880
550
1160
380-415v, 50Hz
3
8 / 8
18.6
17.6
20 / 20
4 + earth
PQHY-P550YSHM-A
69.0
63.0
14.65
13.46
4.70 / 4.68
47
52.5
195 + 195
880 + 880
550
1160
380-415v, 50Hz
3
8 / 8
22.6
20.8
20 / 20
4 + earth
PQHY-P600YSHM-A
76.5
69.0
17.12
15.48
4.46 / 4.45
50
53
195 + 195
880 + 880
550
1160
380-415v, 50Hz
3
8 / 8
26.4
23.9
20 / 20
4 + earth
PQHY-P650, 700, 750, 800, 850, 900YSHM-A
Upper View >
Front View >Left Side View > Cit
y M
ult
iRange
WY
Ser
ies (26-36hp)
Dimensions
Page 185
� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largestoperational water circuit temperature band ever
� 40% height reduction compared to previous YGM-A models
� Combining WY with waste heat energy provides unique application solutions
� Up to 50 indoor units can now be connected to each condensing unit
� Single inverter compressor
� Improved pipe run of 165m with a total system pipe length of up to 500m
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensiblecooling capacity over standard operation is achievable, the result being greater comfort for occupants
� Able to operate with closed loop ground sourcewater temperatures, bore hole and slinkyapplications are now possible
� Easy maintenance - front panel access to all PCB’s
� Condensing units must be situated indoors
WY SERIES HEAT SOURCE UNITS - 26-36hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1100 without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
WY Series (26-36hp)Heat Pump, Water Cooled Condensing Unit
PQHY-P650-900YSHM-A Piping Restrictions
TOTAL PIPING LENGTH
FURTHEST PIPING LENGTH
FURTHEST PIPING LENGTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
500m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max
Technical Information
Page 184
The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heatrecovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A airsource versions, the water cooled units now benefit from a modular design approach. A twinning kit is required.
PQHY-P650YSHM-A
81.5
73.0
14.74
13.96
5.52 / 5.22
50
53
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
22.7
21.5
20 / 20 / 20
4 + earth
PQHY-P700YSHM-A
88.0
80.0
16.51
15.58
5.33 / 5.13
50
53.5
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
25.5
24.0
20 / 20 / 20
4 + earth
PQHY-P750YSHM-A
95.0
85.0
18.27
17.19
5.19 / 4.94
50
54
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
28.2
26.5
20 / 20 / 20
4 + earth
PQHY-P800YSHM-A
100.0
90.0
20.74
19.18
4.82 / 4.69
50
54
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
32.0
29.6
20 / 20 / 20
4 + earth
PQHY-P850YSHM-A
108.0
96.0
23.21
21.20
4.65 / 4.52
50
54.5
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
35.8
32.7
20 / 20 / 20
4 + earth
PQHY-P900YSHM-A
113.0
101.0
25.67
23.22
4.40 / 4.34
50
55
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
3
8 / 8 / 8
39.6
35.8
20 / 20 / 20
4 + earth
Upper View >Front View >Side View >
Cit
y M
ult
iRange
R2 S
erie
s St
andar
d (8-18hp)
PURY-P200, 250, 300YJM-A
Upper View >Front View >Side View >
PURY-P350, 400YJM-A
Upper View >Front View >Side View >
PURY-P450YJM-A
Dimensions
Page 187
R2 Series Standard (8-18hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and viceversa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
� Up to 45 indoor units connected to each outdoor unit
� Easy to install unique 2-pipe technology means minimal disruption,quicker installation and less connections than 3 pipe equivalents
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m with a total systempipe length of up to 600m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation isachievable, the result being greater comfort for occupants
� High Performance Heating Mode forlow ambient conditions
Page 186
R2 SERIES STANDARD OUTDOOR UNITS 8-18hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PURY-P200YJM-A
25.0
22.4
25.0
22.8
21.3
5.69
5.18
7.17
5.63
2.98
4.39 / 4.32
20
185
56
240
920
760
1710
380-415v, 50Hz
3
8
8.7
8.0
20
4 + earth
PURY-P250YJM-A
31.5
28.0
31.5
28.7
26.6
7.32
7.05
9.22
7.25
4.05
4.30 / 3.97
25
185
57
240
920
760
1710
380-415v, 50Hz
3
8
11.3
10.8
20
4 + earth
PURY-P300YJM-A
37.5
33.5
35.6
32.3
31.5
8.78
8.67
11.77
8.52
5.59
4.27 / 3.86
30
185
59
245
920
760
1710
380-415v, 50Hz
3
8
13.5
13.4
25
4 + earth
PURY-P350YJM-A
45.0
40.0
42.8
38.7
37.6
10.89
11.33
14.59
10.56
7.31
4.13 / 3.53
35
225
60
270
1220
760
1710
380-415v, 50Hz
3
8
16.8
17.5
32
4 + earth
PURY-P450YJM-A
56.0
50.0
50.7
48.7
46.0
14.58
14.49
16.62
13.27
9.13
3.84 / 3.45
45
360
62
320
1750
760
1710
380-415v, 50Hz
3
8
22.5
22.3
40
4 + earth
PURY-P400YJM-A
50.0
45.0
47.5
43.0
42.3
12.75
13.55
17.09
12.37
8.74
3.92 / 3.32
40
225
61
270
1220
760
1710
380-415v, 50Hz
3
8
19.7
20.9
40
4 + earth
Technical Information
Note: For piping restrictions for PURY-P200-450YJM-A please see page 196
Cit
y M
ult
iRange
R2 S
erie
s St
andar
d (18-28hp)
PURY-P450YSJM-A1 / PURY-P500, 550, 600YSJM-A
PURY-P650, 700YSJM-A
Dimensions
Side View > Front View >
Page 189
Side View > Front View >
R2 Series Standard (18-28hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
� Up to 50 indoor units connected to each outdoor unit
� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m with a total system pipe length of up to 950m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 188
Technical Information
R2 SERIES STANDARD OUTDOOR UNITS 18-28hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PURY-P450YSJM-A1
56.0
50.0
50.7
48.7
46.0
13.30
12.50
15.16
12.10
7.88
4.21 / 4.00
45
185 / 185
59.5
240 + 240
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
20.5
19.3
20 / 20
4 + earth
PURY-P500YSJM-A
63.0
56.0
57.0
54.8
51.5
15.10
14.85
17.21
13.74
9.36
4.17 / 3.77
50
185 / 185
60
240 + 240
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
23.3
22.9
20 / 20
4 + earth
PURY-P550YSJM-A
69.0
63.0
62.4
60.0
58.0
16.95
17.30
19.32
15.42
10.90
4.07 / 3.64
50
185 / 185
61
245 + 240
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
26.2
26.7
25 / 20
4 + earth
PURY-P600YSJM-A
76.5
69.0
69.2
66.6
63.5
19.07
19.65
21.74
17.35
12.38
4.01 / 3.51
50
185 / 185
62
245 + 245
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
29.4
30.3
25 / 25
4 + earth
PURY-P700YSJM-A
88.0
80.0
88.0
76.6
73.6
22.33
23.95
28.14
20.77
15.45
3.94 / 3.34
50
225 / 185
63
270 + 245
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
34.5
37.0
40 / 25
4 + earth
PURY-P650YSJM-A
81.5
73.0
73.8
70.9
67.2
20.47
21.53
23.34
18.63
13.56
3.98 / 3.39
50
225 / 185
62.5
270 + 245
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
31.6
33.2
32 / 25
4 + earth
Note: For piping restrictions for PURY-P450-700YSJM-A(1) please see page 196
Cit
y M
ult
iRange
R2 S
erie
s St
andar
d (30-36hp)
PURY-P750, 800YSJM-A
PURY-P850YSJM-A
Dimensions
Side View > Front View >
Side View > Front View >
Side View > Front View >
PURY-P900YSJM-A
Page 191
R2 Series Standard (30-36hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas andheating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat fromcooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
� Up to 50 indoor units connected to each outdoor unit
� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m with a total system pipe length of up to 950m
� 100% inverter control
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Mode for low ambient conditions
Page 190
Note: For piping restrictions for PURY-P750-900YSJM-A please see page 196
Technical Information
R2 SERIES STANDARD OUTDOOR UNITS 30-36hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
PURY-P750YSJM-A
95.0
85.0
95.0
82.7
78.2
24.05
26.47
30.30
22.37
17.07
3.95 / 3.21
50
225 / 225
63.5
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
37.1
40.9
40 / 32
4 + earth
PURY-P800YSJM-A
100.0
90.0
100.0
87.0
82.8
26.04
28.30
32.81
24.22
18.25
3.84 / 3.18
50
225 / 225
64
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
40.2
43.7
40 / 40
4 + earth
PURY-P850YSJM-A
108.0
96.0
102.6
95.0
88.3
28.42
29.26
37.80
26.15
17.85
3.80 / 3.28
50
360 / 225
64.5
320 + 270
1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
43.9
45.2
40 / 40
4 + earth
PURY-P900YSJM-A
113.0
101.0
107.4
99.4
92.9
30.05
30.23
39.97
27.65
18.44
3.76 / 3.34
50
360 / 360
65
320 + 320
1750 + 1750
760
1710
380-415v, 50Hz
3
8 / 8
46.4
46.7
40 / 40
4 + earth
Side View > Front View >
Side View > Front View >
PURY-EP400YSJM-A
PURY-EP200, 250, 300, 350YJM-A
PURY-EP450, 500YSJM-A
Cit
y M
ult
iRange
R2 S
erie
s H
igh C
OP (8-20hp)
Dimensions
Page 193
PURY-EP200YJM-A schematic is the same as PURY-P200, 250, 300YJM-A on page 186
PURY-EP250, 300YJM-A schematic is the same as PURY-P350, 400YJM-A on page 186
PURY-EP350YJM-A schematic is the same as PURY-P450YJM-A on page 186
R2 Series High COP (8-20hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms.The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations(and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% overconventional systems.
� Highest ever COP’s / EER’s due to new high efficiency inverter technologyand wrap around coil for added efficiency
� Up to 50 indoor units connected to each outdoor unit
� Easy to install unique 2-pipe technology means minimal disruption,quicker installation and less connections than 3 pipe equivalents
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m with a total system pipe length of up to 750m
� 100% inverter control with low start currents
� High Sensible Cooling Function - By raising the off coil temperature, a 10% increasein sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� High Performance Heating Modefor low ambient conditions
Technical Information
R2 SERIES HIGH COP OUTDOOR UNITS 8-20hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
Page 192
PURY-EP200YJM-A
25.0
22.4
25.0
22.8
21.3
5.56
5.07
7.01
5.50
2.92
4.49 / 4.41
20
185
57
240
920
760
1710
380-415v, 50Hz
3
8
8.5
7.8
20
4 + earth
PURY-EP250YJM-A
31.5
28.0
31.5
28.7
26.6
7.15
6.76
9.01
7.08
3.89
4.40 / 4.14
25
225
60
270
1220
760
1710
380-415v, 50Hz
3
8
11.0
10.4
20
4 + earth
PURY-EP300YJM-A
37.5
33.5
35.6
32.3
31.5
8.60
8.25
11.52
8.34
5.32
4.36 / 4.06
30
225
60
270
1220
760
1710
380-415v, 50Hz
3
8
13.2
12.7
25
4 + earth
PURY-EP350YJM-A
45.0
40.0
42.8
38.7
37.6
10.58
10.28
14.18
10.26
6.63
4.25 / 3.89
35
360
61
320
1750
760
1710
380-415v, 50Hz
3
8
16.3
15.8
32
4 + earth
PURY-EP400YSJM-A
50.0
45.0
47.5
43.0
42.3
11.36
10.41
15.22
11.02
6.71
4.40 / 4.32
40
185 / 185
60
240 + 240
920 + 920
760
1710
380-415v, 50Hz
3
8 / 8
17.5
16.0
20 / 20
4 + earth
PURY-EP450YSJM-A
56.0
50.0
50.7
48.7
46.0
12.87
11.99
14.67
11.71
7.55
4.35 / 4.17
45
225 / 185
62
270 + 240
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
19.8
18.5
20 / 20
4 + earth
PURY-EP500YSJM-A
63.0
56.0
57.0
54.8
51.5
14.38
13.62
16.39
13.09
8.58
4.38 / 4.11
50
225 / 185
62
270 + 240
1220 + 920
760
1710
380-415v, 50Hz
3
8 / 8
22.2
21.0
25 / 20
4 + earth
Note: For piping restrictions for PURY-EP200-500Y(S)JM-A please see page 196
Side View > Front View >
PURY-EP550, 600YSJM-A
PURY-EP650YSJM-A
Cit
y M
ult
iRange
R2 S
erie
s H
igh C
OP (22-28hp)
Dimensions
PURY-EP700YSJM-A
Page 195
Side View > Front View >
Side View > Front View >
R2 Series High COP (22-28hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms.The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations(and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30%over conventional systems.
� Highest ever COP’s / EER’s due to new high efficiency inverter technologyand wrap around coil for added efficiency
� Up to 50 indoor units connected to each outdoor unit
� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
� Weight and size reduction compared to YGM-A models
� Improved pipe run of 165m with a total system pipe length of up to 800m
� 100% inverter control with low start currents
� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants
� High Performance Heating Modefor low ambient conditions
Technical Information
R2 SERIES HIGH COP OUTDOOR UNITS 22-28hpMODEL REFERENCE
CAPACITY (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
COP / EER (nominal)
MAX No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min) High
NOISE (dBA)
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
(1650mm without legs) Height
ELECTRICAL SUPPLY
PHASE
STARTING CURRENT (A)
RUNNING CURRENT (A) Heating
Cooling
FUSE RATING (MCB sizes BS EN 60947-2) - (A)
MAINS CABLE No. Cores
Page 194
PURY-EP550YSJM-A
69.0
63.0
62.4
60.0
58.0
15.93
15.40
18.16
14.50
9.70
4.33 / 4.09
50
225 / 225
63
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
24.6
23.8
25 / 20
4 + earth
PURY-EP600YSJM-A
76.5
69.0
69.2
66.6
63.5
17.38
16.87
19.81
15.82
10.63
4.40 / 4.09
50
225 / 225
63
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
26.8
26.0
25 / 25
4 + earth
PURY-EP650YSJM-A
81.5
73.0
73.8
70.9
67.2
19.73
19.01
22.49
17.95
11.98
4.13 / 3.84
50
360 / 225
63.5
320 + 270
1750 + 1220
760
1710
380-415v, 50Hz
3
8 / 8
30.4
29.3
32 / 25
4 + earth
PURY-EP700YSJM-A
88.0
80.0
88.0
76.6
73.6
22.05
21.22
27.78
20.51
13.69
3.99 / 3.77
50
360 / 360
64
320 + 320
1750 + 1750
760
1710
380-415v, 50Hz
3
8 / 8
34.0
32.8
32 / 32
4 + earth
Note: For piping restrictions for PURY-EP550-700YSJM-A please see page 196
Cit
y M
ult
iRange
R2 S
erie
s Pip
ing
Res
tric
tions
1
ITEM PIPE SECTION MAX LENGTH
R2 SERIES PIPING RESTRICTIONS
PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)
Total Piping Length
Furthest Piping Length
Length Between OU and BC
Length Between Furthest IU and BC
Height Between OU and IU (OU above IU)
Height Between OU and IU (OU below IU)
Height Between IU and BC
Height Between IU and IU
Height Between BC (Main or Sub) and BC (Sub)
A+B+C+D+E+a+b+c+d+e+f
A+C+E+f
A
B+d or C+D+e or C+E+f
H
H1
h1
h2
h3
(See Table 1)
165m
110m*1
60m*2 (40m)
50m
40m
15m
15m
15m
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
ITEM PIPE SECTION MAX LENGTH
R2 SERIES PIPING RESTRICTIONS
PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)
Total Piping Length
Furthest Piping Length
Length Between OU and BC
Length Between Furthest IU and BC
Height Between OU and IU (OU above IU)
Height Between OU and IU (OU below IU)
Height Between IU and BC
Height Between IU and IU
Height Between BC (Main or Sub) and BC (Sub)
Length Between Main OU and Sub OU
Height Between Main OU and Sub OU
F+G+H+A+B+C+D+E+a+b+c+d+e+f
F(G)+A+C+E+f
F(G)+A
B+d or C+D+e or C+E+f
H
H1
h1
h2
h3
F+G or H
h4
(See Table 1)
165m
110m*1
60m*2 (40m)
50m
40m
15m
15m
15m
5m
0.1m
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
1
700 to P800/ EP600 or less
CMY-R100XLVBK: Outdoor unit EP650 and EP700CMY-R200XLVBK: Outdoor unit P850 and P900
Page 197
OUTDOOR MODEL
TABLE 1: TOTAL PIPE LENGTH
R2 SERIES PIPING RESTRICTIONS
GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS
P200, P250, P300, EP200P350, P400, P450, EP250, EP300, EP350P500, P550, EP400, EP450, EP500, EP550P600, P650, EP600, EP650, EP700P700, P750, P800, P850, P900
550m*1
600m*1
750m*1
800m*1
950m*1
*1 Please refer to Graph 1
1000
PURY-P700,750,800,850,900YSJM-A
PURY-P600,650YSJM-A, PURY-EP600,650,700YSJM-A
PURY-P500,550YSJM-A, PURY-EP400,450,500,550YSJM-A
PURY-P350,400,450Y(S)JM-A(1), PURY-EP250,300,350YJM-A
PURY-P200,250,300YJM-A, PURY-EP200YJM-A
900
800
700
600
500
400
300
200
100
0
10 20 30 40 50 60 70 80 90 100 110
Tota
l Exte
nded
Pip
e Le
ngt
h (
m)
Distance Between Outdoor Unit and BC Controller (m)
1
1
R2 SERIES PIPING RESTRICTIONS
ITEM PIPE SECTION MAX LENGTH
R2 SERIES PIPING RESTRICTIONS
PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)
Total Piping Length
Furthest Piping Length
Length Between OU and BC
Length Between Furthest IU and BC
Height Between OU and IU (OU above IU)
Height Between OU and IU (OU below IU)
Height Between IU and BC
Height Between IU and IU
A+B+a+b+c+d
A+B+d
A
B+d
H
H1
h1
h2
(See Table 1)
165m
110m*1
60m*2 (40m)
50m
40m
15m
15m
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
R2 Series Piping Restrictions
Page 196
MAX LENGTH
cit
y m
ult
iR
ange
r2
seri
es r
epla
ce m
ulti (
8-12
hp)
PURY-RP200, 250, 300YJM-B upper view >
Dimensions
Front view >side view >
Page 199
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
r2 series replace multi (8-12hp)
enables the replacement of vrF systems, whilst utilisingexisting r22 / r407c pipework.
Technical Information
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector,enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficientsystems available in the market.
Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil thatwould have ordinarily meant that new pipework would have been called for. The implications of this are significantsavings on cost and time, whilst also minimising any potential disruption.
� tried and tested technology that has been employed for over 5 years
� efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials
� increased energy efficiency - up to 105% (size 200) moreefficient than an old mitsubishi electric r22 system
� reduced installation costs of up to 55%
� reduced co2 emissions and running cost savings of up to 45%
� reduced installation time with minimised disruption
� ability to replace many non mitsubishi electric systems
� high Performance heating mode for low ambient conditions
Page 198
R2 SERIES REPLACE MULTI OUTDOOR UNITS 8-12hpmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
high Performance heating (uK)
coP Priority heating (uK)
cooling (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
high Performance heating (uK)
coP Priority heating (uK)
cooling (uK)
coP / eer (nominal)
max no. oF connectable indoor units
airFlow (m3/min) high
noise (dba)
weight (kg)
dimensions (mm) width
depth
(1650mm without legs) height
electrical suPPly
Phase
starting current (a)
running current (a) heating
cooling
Fuse rating (mcb sizes bs en 60947-2) - (a)
mains cable no. cores
PURY-RP200YJM-B
25.0
22.4
24.0
21.8
21.1
5.50
4.95
7.26
5.34
3.61
4.54 / 4.52
20
225
56
275
1220
760
1710
380-415v, 50hz
3
8
8.9
8.0
20
4 + earth
PURY-RP250YJM-B
31.5
28.0
30.2
27.4
26.3
7.22
6.82
9.53
7.00
4.98
4.36 / 4.10
25
225
57
290
1220
760
1710
380-415v, 50hz
3
8
11.9
11.2
20
4 + earth
PURY-RP300YJM-B
37.5
33.5
36.0
32.6
31.5
8.70
8.35
11.48
8.44
6.10
4.31 / 4.01
30
225
59
290
1220
760
1710
380-415v, 50hz
3
8
14.6
13.6
25
4 + earth
R2 Series Replace Multi Piping Restrictions
total PiPing length 220m max
Furthest PiPing length 100m max
length between ou and bc 70m max
length between Furthest iu and bc 30m max
height between ou and iu (ou above iu) 50m max
height between ou and iu (ou below iu) 40m max
height between iu and bc 15m max
height between iu and iu 15m max
height between bc (main or sub) and sub bc 15m max
cit
y m
ult
iR
ange
wr
2 se
ries
(8-
24hp
)
PQRY-P200, 250, 300YHM-A
PQRY-P400, 450, 500, 550, 600YSHM-A
upper view >
Front view > right side view >
Front view >left side view >
Dimensions
Page 201
WR2 SERIES HEAT SOURCE UNITS - 8-24hp
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
Power inPut (kw) heating (nominal)
cooling (nominal)
coP / eer (nominal)
max no. oF connectable indoor units
noise (dba)
weight (kg)
dimensions (mm) width
depth
(1100 without legs) height
electrical suPPly
Phase
starting current (a)
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PQRY-P200YHM-A
25.0
22.4
4.12
3.96
6.06 / 5.65
20
47
181
880
550
1160
380-415v, 50hz
3
8
6.3
6.1
20
4 + earth
PQRY-P250YHM-A
31.5
28.0
5.80
5.51
5.43 / 5.08
25
49
181
880
550
1160
380-415v, 50hz
3
8
8.9
8.5
20
4 + earth
PQRY-P300YHM-A
37.5
33.5
8.15
7.44
4.60 / 4.50
30
50
181
880
550
1160
380-415v, 50hz
3
8
12.5
11.5
20
4 + earth
PQRY-P400YSHM-A
50.0
45.0
8.65
8.32
5.78 / 5.40
40
50
181 + 181
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
13.3
12.8
20 / 20
4 + earth
PQRY-P450YSHM-A
56.0
50.0
10.42
9.94
5.37 / 5.03
45
51
181 + 181
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
16.1
15.3
20 / 20
4 + earth
PQRY-P500YSHM-A
63.0
56.0
12.06
11.57
5.22 / 4.84
50
52
181 + 181
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
18.6
17.8
20 / 20
4 + earth
PQRY-P550YSHM-A
69.0
63.0
14.65
13.60
4.70 / 4.63
50
52.5
181 + 181
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
22.6
21.0
20 / 20
4 + earth
PQRY-P600YSHM-A
76.5
69.0
17.12
15.62
4.46 / 4.41
50
53
181 + 181
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
26.4
24.1
20 / 20
4 + earth
wr2 series (8-24hp)Water Cooled Condensing UnitSimultaneous Heating and Cooling with Double Heat Recovery
PQRY-P200-600Y(S)HM-A Piping restrictions
total PiPing length
Furthest PiPing length
between outdoor and bc controller (master) - length
between indoor and bc controller (master/slave) - length
between indoor and outdoor - height
between indoor and indoor - height
between indoor and bc controller (master/slave) - height
between bc controller (master) and bc controller (slave) - height
550m max*3 (300m) for sizes 200-300 / 750m max*3 (500m) for sizes 400-600
165m max
110m max*4
60m max*5 (40m)
50m max (40m*1)
15m max (10m*2)
15m max (10m*2)
15m max (10m)*6
Technical Information
The WR2 system has double heat recovery potential, making this system very economical. Not only does it produceheat recovery from indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuitbetween heat source units. Like the YHM-A air source versions, the water cooled units now benefit from a modulardesign approach. A twinning kit is required for double combinations.
� all the benefits of the r2 series with water cooled condensing units, using a single inverter compressor
� 40% height reduction compared to previous ygm-a models
� high coPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever
� unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between up to 50 indoor units as with the r2 system
� total building heat recovery made possible by exchanging energy in both refrigerant and water circuits
� combining wr2 with waste heat energy provides unique application solutions
� improved pipe run of 165m with a total system pipe length of up to 750m
� high sensible cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
� able to operate with closed loop ground source water temperatures,bore hole and slinky applications are now possible
� easy maintenance - front panel access to all Pcb’s
� condensing units must be situated indoors
Page 200
*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 10m or less *4 Total piping length is 300m or less (500m for sizes 400-600) *5 Height difference between the Master BC Controller and furthest indoor unit is zero and no size 200 or 250 indoor unit is used *6 When using 2 sub BC Controllers, the height between them should be considered
PFD-P250VM-E
PFD-P500VM-E
upper view >
Front view > side view >
upper view >
Front view > side view >
cit
y m
ult
iR
ange
PFd
-P-v
m-e
(10
/20h
p)
Dimensions
Page 203
Heat Pump Close Control System
PFd-P-vm-e (10/20hp)
PUHY-P-YJM-A - OUTDOOR UNITSPFD-P-VM-E - INDOOR UNITS
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
heating (uK)
cooling (uK)
shF
Power inPut (kw) heating (nominal)
cooling (nominal)
heating (uK)
cooling (uK)
airFlow (m3/min)
external static Pressure (Pa)
PiPe siZe mm(in) gas
liquid
noise (dba)
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
starting current (a)
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PFD-P250VM-E
31.5
28.0
29.1
26.6
0.93
2.5
2.5
n/a
n/a
160
120
22.2 (7/8”)
9.52 (3/8”)
59
380
1380
780
1950
380-415v, 50hz
3
47
4.9
4.9
16
4 + earth
PFD-P500VM-E
63.0
56.0
55.4
51.5
0.93
5.0
5.0
n/a
n/a
320
120
22.2 (7/8”)
9.52 (3/8”)
63
520
1980
780
1950
380-415v, 50hz
3
68
8.7
8.7
20
4 + earth
PFD-P-VM-E Piping restrictions
total PiPing length
between indoor and outdoor units - height
165m max
50m max (40m max if outdoor installed below)
Technical Information
Mitsubishi Electric’s new Close Control System is specifically designed forcomputer rooms, laboratories etc, where a need for high sensible cooling andclose control of temperature and humidity is required. Because of the needfor close control 24 hours a day, 365 days a year, a newly developed inverterdriven compressor has been incorporated into the outdoor unit, maximisingthe energy efficiency of the PFD series. It is also able to be connected to a computer network using our AG150 controller, in order to monitor andprovide remote email alarms.
� high sensible cooling
� newly developed inverter driven compressor
� energy efficient with high coP’s
� close control of temperature, ±1ºc
� easy to install - no service space needed at the rear of the unit
� optional third party humidifier available
� Quick recovery following power failure
� return or discharge air temperature control
� back-up & rotate function available
� connectable to Puhy-P250yJm-a from april 2011
Page 202
PUHY-P250YJM-A
31.5
28.0
28.7
26.6
n/a
refer to databook
refer to databook
refer to databook
refer to databook
170
n/a
22.2 (7/8”)
9.52 (3/8”)
58
200
920
760
1710
380-415v, 50hz
3
8
refer to databook
refer to databook
20
4 + earth
PUHY-P250YJM-A x2
63.0
56.0
54.8
51.5
n/a
refer to databook
refer to databook
refer to databook
refer to databook
170 / 170
n/a
22.2 (7/8”)
9.52 (3/8”)
58 / 58
200 + 200
920 + 920
760
1710
380-415v, 50hz
3
8 / 8
refer to databook
refer to databook
20 / 20
4 + earth
PQHY-P-YHM-A - CONDENSING UNITS
PQHY-P250YHM-A
31.5
28.0
n/a
n/a
n/a
5.51
5.45
n/a
n/a
n/a
n/a
22.2 (7/8”)
9.52 (3/8”)
49
195
880
550
1160
380-415v, 50hz
3
8
8.5
8.4
20
4 + earth
PQHY-P250YHM-A x2
63.0
56.0
n/a
n/a
n/a
5.51 / 5.51
5.45 / 5.45
n/a
n/a
n/a
n/a
22.2 (7/8”)
9.52 (3/8”)
49 / 49
195 + 195
880 + 880
550
1160
380-415v, 50hz
3
8 / 8
8.5 / 8.5
8.4 / 8.4
20 / 20
4 + earth
PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E
MODELS
PlFy-P32-80vbm-e
PlFy-P100-125vbm-e
A
241
281
B
258
298
upper view >
lower view >
side view >
cit
y m
ult
iR
ange
PlF
y-P-v
bm
-e
Dimensions
Page 205
PlFy-P-vbm-e2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P-VBM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg) (grille)
dimensions (mm) width (grille)
depth (grille)
height (grille)
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
grille model reFerence
PLFY-P32VBM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.82
0.96
0.02
0.03
11-12-13-14
27-28-29-31
22(6)
840(950)
840(950)
258(35)
220-240v, 50hz
single
0.14
0.22
6
3
PlP-6ba
PLFY-P50VBM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.75
0.83
0.03
0.04
12-13-14-16
27-28-30-31
22(6)
840(950)
840(950)
258(35)
220-240v, 50hz
single
0.22
0.29
6
3
PlP-6ba
PLFY-P80VBM-E
10.0
9.0
10.0
9.4
8.5
6.5
0.72
0.78
0.06
0.07
16-18-20-22
30-32-35-37
23(6)
840(950)
840(950)
258(35)
220-240v, 50hz
single
0.43
0.51
6
3
PlP-6ba
PLFY-P125VBM-E
16.0
14.0
16.0
15.0
13.3
10.2
0.70
0.75
0.15
0.16
22-25-28-30
35-38-41-43
27(6)
840(950)
840(950)
298(35)
220-240v, 50hz
single
1.00
1.07
6
3
PlP-6ba
PLFY-P40VBM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.79
0.91
0.03
0.04
12-13-14-16
27-28-30-31
22(6)
840(950)
840(950)
258(35)
220-240v, 50hz
single
0.22
0.29
6
3
PlP-6ba
PLFY-P63VBM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.04
0.05
14-15-16-18
28-29-30-32
23(6)
840(950)
840(950)
258(35)
220-240v, 50hz
single
0.29
0.36
6
3
PlP-6ba
PLFY-P100VBM-E
12.5
11.2
12.5
11.7
10.6
8.1
0.72
0.79
0.14
0.15
21-24-27-29
34-37-39-41
27(6)
840(950)
840(950)
298(35)
220-240v, 50hz
single
0.94
1.00
6
3
PlP-6ba
Technical Information
Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to4.2 metres in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustablevanes that allow users to precisely direct air where it’s needed.
The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reducesdrafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface.
� handy corner pocket design simplifies maintenance
� airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
� reduced draft air distribution, with independent vane control
� drain pump as standard, 850mm from drain pan
� Filter lowering operation down to 4m (optional PlP-6baJ grille required)
� optional ‘i see sensor’ for energy saving and smooth temperature control throughout the room
� For further information on the features of this cassette,please see page 72
Page 204
PLFY-P20, 25, 32, 40VCM-E2
lower view >
side view >
cit
y m
ult
iR
ange
PlFy
-P-v
cm
-e2
Dimensions
Page 207
PlFy-P-vcm-e2
The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.
600x600 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P-VCM-E2 - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi-hi
noise (dba) lo-mi-hi
weight (kg) (grille)
dimensions (mm) width (grille)
depth (grille)
height (grille)
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
grille model reFerence
PLFY-P20VCM-E2
2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.05
0.05
8-9-10
28-31-35
15.5(3)
570(650)
570(650)
235(20)
220-240v, 50hz
single
0.23
0.23
6
3
slP-2aaw
PLFY-P25VCM-E2
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.95
0.05
0.05
8-9-10
28-31-37
15.5(3)
570(650)
570(650)
235(20)
220-240v, 50hz
single
0.23
0.23
6
3
slP-2aaw
PLFY-P32VCM-E2
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.06
0.06
8-9-11
29-33-38
17(3)
570(650)
570(650)
235(20)
220-240v, 50hz
single
0.28
0.28
6
3
slP-2aaw
PLFY-P40VCM-E2
5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
0.06
0.06
8-9-11
30-34-39
17(3)
570(650)
570(650)
235(20)
220-240v, 50hz
single
0.28
0.28
6
3
slP-2aaw
Technical Information
� compact size for handy installation and easy maintenance
� only 208mm high
� Fresh air duct facility
Page 206
PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E
PLFY-P125VLMD-E
Front view >
lower view >
side view > upper view >
CMP-40VLW-C
CMP-63VLW-C
CMP-100VLW-C
side view >
rear view > lower view >
cit
y m
ult
iR
ange
PlF
y-P-v
lmd
-e
Dimensions
Page 209
PlFy-P-vlmd-e2-Way Blow Ceiling Cassette Indoor Unit
PLFY-P-VLMD-E - INDOOR UNITS
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg) (grille)
dimensions (mm) width (grille)
depth (grille)
height (grille)*1
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
grille model reFerence
PLFY-P20VLMD-E
2.5
2.2
2.5
2.3
2.1
1.6
0.90
1.00
0.065
0.072
6.5-8.0-9.5
27-30-33
23(6.5)
776(1080)
634(710)
290(20)
220-240v,
50hz
single
0.30
0.36
6
3
cmP-
40vlw-c
PLFY-P25VLMD-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
0.065
0.072
6.5-8.0-9.5
27-30-33
23(6.5)
776(1080)
634(710)
290(20)
220-240v,
50hz
single
0.30
0.36
6
3
cmP-
40vlw-c
PLFY-P32VLMD-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.85
0.065
0.072
6.5-8.0-9.5
27-30-33
24(6.5)
776(1080)
634(710)
290(20)
220-240v,
50hz
single
0.30
0.36
6
3
cmP-
40vlw-c
PLFY-P40VLMD-E
5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
0.074
0.081
7.0-8.5-10.5
29-33-36
24(6.5)
776(1080)
634(710)
290(20)
220-240v,
50hz
single
0.34
0.40
6
3
cmP-
40vlw-c
PLFY-P50VLMD-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
0.075
0.082
9.0-11.0-12.5
31-34-37
27(7.5)
946(1250)
634(710)
290(20)
220-240v,
50hz
single
0.35
0.41
6
3
cmP-
63vlw-c
PLFY-P63VLMD-E
8.0
7.1
8.0
7.5
6.7
5.2
0.70
0.75
0.094
0.101
10.0-13.0-15.5
32-37-39
28(7.5)
946(1250)
634(710)
290(20)
220-240v,
50hz
single
0.43
0.49
6
3
cmP-
63vlw-c
PLFY-P80VLMD-E
10.0
9.0
10.0
9.4
8.5
6.5
0.73
0.82
0.140
0.147
15.5-18.5-22.0
33-36-39
44(12.5)
1446(1750)
634(710)
290(20)
220-240v,
50hz
single
0.66
0.72
6
3
cmP-
100vlw-c
PLFY-P100VLMD-E
12.5
11.2
12.5
11.7
10.6
8.1
0.73
0.79
0.150
0.157
17.5-21.0-25.0
36-39-42
47(12.5)
1446(1750)
634(710)
290(20)
220-240v,
50hz
single
0.69
0.75
6
3
cmP-
100vlw-c
PLFY-P125VLMD-E
16.0
14.0
16.0
15.0
13.3
10.2
0.73
0.80
0.27
0.28
24-27-30-33
40-42-44-46
56(13)
1708(2010)
606(710)
290(20)
220-240v,
50hz
single
1.33
1.35
6
3
cmP-
125vlw-c
Technical Information
The PLFY-P-VLMD-E cassette unit fits into the space in a suspendedceiling to provide heating or cooling. This new unit has been redesigned with lower unit height and lower noise levels.
� light unit for ease of installation
� terminal block on outside of unit for easy wiring
� drain lift-pump mechanism as standard
� newly designed pure white decoration panel withair flow switching and swing functions as standard
Page 208
*1 Void space required is 350mm or more
upper view >
lower view >
side view >
upper view >
Front view >
PMFY-P20, 25, 32, 40VBM-E
cit
y m
ult
iR
ange
Pm
Fy-P
-vb
m-e
Dimensions
Page 211
PmFy-P-vbm-e1-Way Blow Ceiling Cassette Indoor Unit
PMFY-P-VBM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg) (grille)
dimensions (mm) width (grille)
depth (grille)
height (grille)
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
grille model reFerence
PMFY-P20VBM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.042
0.042
6.5-7.2-8.0-8.7
27-30-33-35
14(3)
812(1000)
395(470)
230(30)
220-240v, 50hz
single
0.20
0.20
6
3
PmP-40bmw
PMFY-P25VBM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.81
0.95
0.044
0.044
7.3-8.0-8.6-9.3
32-34-36-37
14(3)
812(1000)
395(470)
230(30)
220-240v, 50hz
single
0.21
0.21
6
3
PmP-40bmw
PMFY-P32VBM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.044
0.044
7.3-8.0-8.6-9.3
32-34-36-37
14(3)
812(1000)
395(470)
230(30)
220-240v, 50hz
single
0.21
0.21
6
3
PmP-40bmw
PMFY-P40VBM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.82
0.054
0.054
7.7-8.7-9.7-10.7
33-35-37-39
14(3)
812(1000)
395(470)
230(30)
220-240v, 50hz
single
0.26
0.26
6
3
PmP-40bmw
Technical Information
Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest.
� compact size for handy installation and easy maintenance
� newly developed airflow control technology reduces noise levels to only 27dba
� drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceiling’s surface
� only 230mm high
� Fresh air duct facility
� Pure white grille
Page 210
PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E
a bPeFy-P15-32vms1-e 700 752
PeFy-P40-50vms1-e 900 952
c798
998
d660
860
e7
9
F600
800
PeFy-P63vms1-e 1100 1152 1198 1060 11 1000
model
side view >
Front view >
upper view >
cit
y m
ult
iR
ange
PeF
y-P-v
ms1
-e
Dimensions
Page 213
PeFy-P-vms1-eUltra Thin Ceiling Concealed Ducted Indoor Unit
The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularlysuitable for places where low noise operation is desired from a slimline body.
� ultra thin body - height of only 200mm & width of only 790mm (P15-32)
� extremely quiet operation - as low as 22dba
� cooling operation set temperature can be set down to 14°c db
� static pressure of 5-50Pa
� now available in a size 15, ideal for hotel rooms
PEFY-P-VMS1-E - INDOOR UNITS
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi-hi
external static Pressure (Pa) lo-mi1-mi2-hi
noise (dba) (15Pa) lo-mi-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PEFY-P15VMS1-E
1.9
1.7
1.9
1.8
1.6
1.2
0.94
1.00
0.03
0.05
5.0-6.0-7.0
5-15-35-50
22-24-28
19
790
700
200
220-240v, 50hz
single
0.31
0.42
6
3
PEFY-P25VMS1-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
0.04
0.06
5.5-7.0-9.0
5-15-35-50
24-26-30
19
790
700
200
220-240v, 50hz
single
0.39
0.50
6
3
PEFY-P40VMS1-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.82
0.05
0.07
8.0-9.5-11.0
5-15-35-50
28-30-33
24
990
700
200
220-240v, 50hz
single
0.45
0.56
6
3
PEFY-P63VMS1-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.07
0.09
12.0-14.0-16.5
5-15-35-50
30-33-36
28
1190
700
200
220-240v, 50hz
single
0.61
0.72
6
3
PEFY-P20VMS1-E
2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.03
0.05
5.5-6.5-8.0
5-15-35-50
22-25-29
19
790
700
200
220-240v, 50hz
single
0.36
0.47
6
3
PEFY-P32VMS1-E
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.05
0.07
6.0-8.0-10.0
5-15-35-50
24-27-32
20
790
700
200
220-240v, 50hz
single
0.39
0.50
6
3
PEFY-P50VMS1-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
0.07
0.09
9.5-11.0-13.0
5-15-35-50
30-32-35
24
990
700
200
220-240v, 50hz
single
0.56
0.67
6
3
Technical Information
Page 212
PEFY-P20, 25, 32, 40, 50, 63, 80, 100, 125VMA-E
side view >
upper view >
Front view >
cit
y m
ult
iR
ange
PeF
y-P-v
ma
-e
Dimensions
Page 215
rear view >
a bPeFy-P20-32vma-e 700 754
PeFy-P40-50vma-e 900 954
PeFy-P63-80vma-e 1100 1154
c800
1000
1200
d660
860
1060
e7
9
11
PeFy-P100-125vma-e 1400 1454 1500 1360 14
F600
800
1000
g658
858
1058
1300 1358
model
PeFy-P-vma-eCeiling Concealed Ducted Indoor Unit
PEFY-P-VMA-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi-hi
external static Pressure (Pa) - lo-mi1-mi2-mi3-hi
noise (dba) (50Pa) lo-mi-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PEFY-P20VMA-E
2.5
2.2
2.5
2.3
2.1
1.6
0.90
1.00
0.04
0.06
6.0-7.5-8.5
35-50-70-100-150
23-25-26
23
700
732
250
220-240v,
50hz
single
0.42
0.53
6
3
PEFY-P25VMA-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
0.04
0.06
6.0-7.5-8.5
35-50-70-100-150
23-25-26
23
700
732
250
220-240v,
50hz
single
0.42
0.53
6
3
PEFY-P32VMA-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.85
0.05
0.07
7.5-9.0-10.5
35-50-70-100-150
23-26-29
23
700
732
250
220-240v,
50hz
single
0.44
0.55
6
3
PEFY-P40VMA-E
5.0
4.5
5.0
4.7
4.3
3.3
0.79
0.91
0.07
0.09
10-12-14
35-50-70-100-150
23-27-30
26
900
732
250
220-240v,
50hz
single
0.53
0.64
6
3
PEFY-P50VMA-E
6.3
5.6
6.3
5.9
5.3
4.1
0.79
0.88
0.09
0.11
12.0-14.5-17.0
35-50-70-100-150
25-29-32
26
900
732
250
220-240v,
50hz
single
0.63
0.74
6
3
PEFY-P63VMA-E
8.0
7.1
8.0
7.5
6.7
5.2
0.78
0.87
0.10
0.12
13.5-16.0-19.0
35-50-70-100-150
25-29-33
32
1100
732
250
220-240v,
50hz
single
0.90
1.01
6
3
PEFY-P80VMA-E
10.0
9.0
10.0
9.4
8.5
6.5
0.72
0.78
0.12
0.14
14.5-18.0-21.0
35-50-70-100-150
26-29-34
32
1100
732
250
220-240v,
50hz
single
1.04
1.15
6
3
PEFY-P100VMA-E
12.5
11.2
12.5
11.7
10.6
8.1
0.79
0.89
0.22
0.24
23-28-33
35-50-70-100-150
28-33-37
42
1400
732
250
220-240v,
50hz
single
1.36
1.47
6
3
PEFY-P125VMA-E
16.0
14.0
16.0
15.0
13.3
10.2
0.77
0.86
0.32
0.34
28-34-40
35-50-70-100-150
32-36-40
42
1400
732
250
220-240v,
50hz
single
1.94
2.05
6
3
Technical Information
The PEFY-P-VMA-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.
� reduced height - now only 250mm
� wider range of external static pressure settings across entire range
� reduced noise levels thanks to the use of a newly designed centrifugal fan- as low as 23dba
� cooling operation set temperature can be set down to 14ºc db
� drain pump included as standard
Page 214
PEFY-P80, 100, 125, 140VMH-E
PEFY-P250VMH-E
side view >upper view >
side view >upper view >
cit
y m
ult
iR
ange
PeF
y-P-v
mh
-e
Dimensions
Page 217
PeFy-P-vmh-eHigh Static Pressure Ceiling Concealed Ducted Indoor Unit
PEFY-P-VMH-E - INDOOR UNITS
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-hi
external static Pressure (Pa) - lo-mi-hi
noise (dba) (150Pa) lo-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PEFY-P80VMH-E
10.0
9.0
10.0
9.4
8.5
6.5
0.74
0.83
0.32
0.32
18-25
100-150-200
38-43
50
1000
900
380
220-240v, 50hz
single
1.47
1.47
6
3
PEFY-P100VMH-E
12.5
11.2
12.5
11.7
10.6
8.1
0.80
0.91
0.48
0.48
26.5-38.0
100-150-200
38-44
70
1200
900
380
220-240v, 50hz
single
2.34
2.34
6
3
PEFY-P125VMH-E
16.0
14.0
16.0
15.0
13.3
10.2
0.74
0.81
0.48
0.48
26.5-38.0
100-150-200
38-44
70
1200
900
380
220-240v, 50hz
single
2.34
2.34
6
3
PEFY-P140VMH-E
18.0
16.0
18.0
16.8
15.2
11.6
0.74
0.82
0.48
0.48
28-40
100-150-200
38-44
70
1200
900
380
220-240v, 50hz
single
2.35
2.35
6
3
PEFY-P250VMH-E
31.5
28.0
31.5
29.5
26.5
20.3
0.75
0.84
1.23
1.23
72
130-260
52 (130Pa)
100
1250
1120
470
380-415v, 50hz
3
2.0
2.0
6
5
Technical Information
With improved design flexibility as a result of increased externalstatic pressure, the PEFY-P-VMH-E allows authentic duct airconditioning within the strictest aesthetic confines.
� external static pressure of up to 260Pa
� greater flexibility for duct extension,branching air outlet configuration
� reduced noise levels thanks to the useof newly designed centrifugal fan
� duct can be connected to intake side
� drain lift-pump (option) 550mm of lift
� cooling operation set temperature can be set down to 14ºc db
Page 216
84
88
195 230
57
254
476
680
182 85 878
960 2 2 853 5
10 51
236
PCFY-P40VKM-E
8488
195 230
5725
447
668
0
182 851198
1280 221173 5
1051
236
PCFY-P63VKM-E
510
51
236
8488
195 230
5725
447
668
0
182 851518
1600 221493
PCFY-P100, 125VKM-E
lower view >
side view >Front view >
cit
y m
ult
iR
ange
Pc
Fy-P
-vK
m-e
Dimensions
Page 219
lower view >
side view >Front view >
lower view >
side view >Front view >
PcFy-P-vKm-eCeiling Suspended Indoor Unit
PCFY-P-VKM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PCFY-P40VKM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.04
0.04
10-11-12-13
29-32-34-36
24
960
680
230
220-240v, 50hz
single
0.28
0.28
6
3
PCFY-P63VKM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.72
0.77
0.05
0.05
14-15-16-18
31-33-35-37
32
1280
680
230
220-240v, 50hz
single
0.33
0.33
6
3
PCFY-P100VKM-E
12.5
11.2
12.5
11.7
10.6
8.1
0.70
0.75
0.09
0.09
21-24-26-28
36-38-41-43
36
1600
680
230
220-240v, 50hz
single
0.65
0.65
6
3
PCFY-P125VKM-E
16.0
14.0
16.0
15.0
13.3
10.2
0.69
0.75
0.11
0.11
21-24-27-31
36-39-42-44
38
1600
680
230
220-240v, 50hz
single
0.76
0.76
6
3
Technical Information
Designed for ultra-quiet operation and easy maintenance, the unit provides comfortable air conditioning for a wide range of applications where floor or wall space cannot be used practically.
� indoor unit designed for direct ceiling suspension
� Flush to wall installation for concealment of service connections
� drain piping can be connected from left or right
Page 218
1170
365
74 (855) 241 5295
249 5155688
898
55
295
PKFY-P15, 20, 25VBM-E
PKFY-P32, 40, 50VHM-E
right side view >Front view >
right side view >Front view >
PKFY-P63VKM-E
right side view >Front view >
cit
y m
ult
iR
ange
PKFy
-P-v
bm
-e / P
KFy
-P-v
hm
-e / P
KFy
-P-v
Km
-e
Dimensions
Page 221
PKFy-P-vbm-e/vhm-e/vKm-eWall Mounted Indoor Units
PKFY-P-VBM-E / VHM-E / VKM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PKFY-P15VBM-E
1.9
1.7
1.9
1.8
1.6
1.2
0.75
0.83
0.04
0.04
4.9-5.0-5.2-5.3
29-31-32-33
10
815
225
295
220-240v, 50hz
single
0.20
0.20
6
3
Technical Information
An elegant design combined with compact dimensions and quiet operationmake the PKFY-P an ideal unit choice. Noise levels are significantly reducedthanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air.
� compact flat panel design - only 815mm wide (vbm-e)
� Front grille opening for easy cleaning
� Front power supply for easy wiring after installation
� 5-way piping provides more flexibility in selection of installation sites
Page 220
PKFY-P20VBM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.71
0.75
0.04
0.04
4.9-5.2-5.6-5.9
29-31-34-36
10
815
225
295
220-240v, 50hz
single
0.20
0.20
6
3
PKFY-P25VBM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
4.9-5.2-5.6-5.9
29-31-34-36
10
815
225
295
220-240v, 50hz
single
0.20
0.20
6
3
PKFY-P32VHM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.03
0.04
9-10-11
34-37-41
13
898
249
295
220-240v, 50hz
single
0.30
0.40
6
3
PKFY-P40VHM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.74
0.82
0.03
0.04
9-10.5-11.5
34-38-41
13
898
249
295
220-240v, 50hz
single
0.30
0.40
6
3
PKFY-P63VKM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.78
0.85
0.04
0.05
16-20
39-45
21
1170
295
365
220-240v, 50hz
single
0.30
0.37
6
3
PKFY-P50VHM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
0.03
0.04
9-10.5-12
34-39-43
13
898
249
295
220-240v, 50hz
single
0.30
0.40
6
3
PFFY-P20, 25, 32, 40, 50, 63VLRM-E
side view >
upper view >
Front view > cit
y m
ult
iR
ange
PFF
y-P-v
lrm
-e
Dimensions
Page 223
PFFy-P-vlrm-eFloor Standing Concealed Indoor Unit
PFFY-P-VLRM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-hi
noise (dba) lo-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PFFY-P20VLRM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
5.5-6.5
34-40
18.5
886
220
639
220-240v, 50hz
single
0.19
0.19
6
3
PFFY-P25VLRM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
5.5-6.5
34-40
18.5
886
220
639
220-240v, 50hz
single
0.19
0.19
6
3
PFFY-P32VLRM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.06
0.06
7-9
35-40
20
1006
220
639
220-240v, 50hz
single
0.29
0.29
6
3
PFFY-P40VLRM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.065
0.065
9-11
38-43
21
1006
220
639
220-240v, 50hz
single
0.32
0.32
6
3
PFFY-P50VLRM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.085
0.085
12-14
38-43
25
1246
220
639
220-240v, 50hz
single
0.40
0.40
6
3
PFFY-P63VLRM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.10
0.10
12-15.5
40-46
27
1246
220
639
220-240v, 50hz
single
0.46
0.46
6
3
A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mmdeep offers an unobtrusive method of delivering highly efficient air-conditioning performance.
� concealed unit for hidden installation
� ideal for perimeter refurbishments
� cooling operation set temperaturecan be set down to 14ºc db
Technical Information
Page 222
PFFY-P20, 25, 32, 40, 50, 63VLRMM-E
side view >
upper view >
Front view >
cit
y m
ult
iR
ange
PFF
y-P-v
lrm
m-e
Dimensions
Page 225
PFFy-P-vlrmm-eFloor Standing Concealed Indoor Unit
A compact concealed unit providing simple, effective air conditioningin perimeter zones. The unit is easy to install and at only 220mmdeep offers an unobtrusive method of delivering highly efficient air-conditioning performance.
PFFY-P-VLRMM-E - INDOOR UNITS
model reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi-hi
external static Pressure (Pa) lo-mi-hi
noise (dba) (20Pa) lo-mi-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PFFY-P20VLRMM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
4.5-5.5-6.5
20-40-60
31-36-40
18.5
886
220
639
220-240v, 50hz
single
0.34
0.34
6
3
PFFY-P32VLRMM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.04
0.04
6.5-7.5-9
20-40-60
27-32-37
20
1006
220
639
220-240v, 50hz
single
0.38
0.38
6
3
PFFY-P50VLRMM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.05
0.05
10-12-14
20-40-60
32-37-41
25
1246
220
639
220-240v, 50hz
single
0.48
0.48
6
3
PFFY-P25VLRMM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
4.5-5.5-6.5
20-40-60
31-36-40
18.5
886
220
639
220-240v, 50hz
single
0.34
0.34
6
3
PFFY-P40VLRMM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.05
0.05
8-9.5-11
20-40-60
30-36-40
21
1006
220
639
220-240v, 50hz
single
0.43
0.43
6
3
PFFY-P63VLRMM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.07
0.07
11-13-15.5
20-40-60
35-40-44
27
1246
220
639
220-240v, 50hz
single
0.59
0.59
6
3
Technical Information
Page 224
� reduced noise levels compared to the PFFy-P-vlrm-e version
� cooling operation set temperature can be set down to 14ºc db
� static pressure. the new unit has 3 static pressure settings- 20/40/60Pa ideal for ducting in the perimeter zone
� concealed unit for hidden installation. the unit can be hidden behind a wardrobe in a hotel, then ducted above and below the wardrobe doors. this offerslower noise, less disruption and a low visual impact
PFFY-P20,25,32,40,50,63VLEM-E
side view >
upper view >
Front view >
cit
y m
ult
iR
ange
PFF
y-P-v
lem
-e
Dimensions
Page 227
PFFy-P-vlem-eFloor Standing Exposed Indoor Unit
PFFY-P-VLEM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-hi
noise (dba) lo-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PFFY-P20VLEM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
5.5-6.5
34-40
23
1050
220
630
220-240v, 50hz
single
0.19
0.19
6
3
PFFY-P25VLEM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
5.5-6.5
34-40
23
1050
220
630
220-240v, 50hz
single
0.19
0.19
6
3
PFFY-P32VLEM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.06
0.06
7-9
35-40
25
1170
220
630
220-240v, 50hz
single
0.29
0.29
6
3
PFFY-P40VLEM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.065
0.065
9-11
38-43
26
1170
220
630
220-240v, 50hz
single
0.32
0.32
6
3
PFFY-P50VLEM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.085
0.085
12-14
38-43
30
1410
220
630
220-240v, 50hz
single
0.40
0.40
6
3
PFFY-P63VLEM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.10
0.10
12-15.5
40-46
32
1410
220
630
220-240v, 50hz
single
0.46
0.46
6
3
A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mmdeep offers an unobtrusive method of delivering a highly efficient air-conditioning performance.
� remote controller can be incorporated into the main unit
� cooling operation set temperature can be set down to 14ºc db
Technical Information
Page 226
PFFY-P20,25,32,40VKM-E
Front view >
upper view >
side view >
cit
y m
ult
iR
ange
PFF
y-P-v
Km
-e
Dimensions
Page 229
PFFy-P-vKm-eFloor Standing Exposed Indoor Unit
PFFY-P-VKM-E - INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
high sensible cooling (uK)
shF (uK)
high sensible (uK)
Power inPut (kw) heating (nominal)
cooling (nominal)
airFlow (m3/min) lo-mi1-mi2-hi
noise (dba) lo-mi1-mi2-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) heating
cooling
Fuse rating (bs88) - hrc (a)
mains cable no. cores
PFFY-P20VKM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.025
0.025
5.9-6.8-7.6-8.7
27-31-34-37
15
700
200
600
220-240v, 50hz
single
0.20
0.20
6
3
PFFY-P25VKM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.74
0.85
0.025
0.025
6.1-7.0-8.0-9.1
28-32-35-38
15
700
200
600
220-240v, 50hz
single
0.20
0.20
6
3
PFFY-P32VKM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.71
0.77
0.025
0.025
6.1-7.0-8.0-9.1
28-32-35-38
15
700
200
600
220-240v, 50hz
single
0.20
0.20
6
3
PFFY-P40VKM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
0.028
0.028
8.0-9.0-9.5-10.7
35-38-42-44
15
700
200
600
220-240v, 50hz
single
0.24
0.24
6
3
The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.
� Pure white, slimline design
� upper and lower vanes for optimum, powerful and efficient air distribution
Technical Information
Page 228
GUF-50/100RD3
side view >
upper view >
Front view >
cit
y m
ult
iR
ange
gu
F-r
d3
Dimensions
Page 231
OUTDOOR AIR PROCESSING INDOOR UNITSmodel reFerence
caPacity (kw) heating (nominal)
cooling (nominal)
hP heating (uK)
coP P heating (uK)
cooling (uK)
Power inPut (kw)
airFlow (m3/h) lo-hi
external static Pressure (Pa)
noise (dba) lo-hi
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a) lo-hi
Fuse rating (bs88) - hrc (a)
mains cable no. cores
GUF-50RD3
6.42 (2.25)
5.29 (1.66)
6.42 (2.25)
5.93 (2.08)
5.03 (1.58)
0.265
400-500
140
33.5-34.5
54
1016
1288
317
220-240v, 50hz
single
0.70-1.15
6
3
GUF-100RD3
13.00 (4.70)
10.81 (3.49)
13.00 (4.70)
12.01 (4.34)
10.27 (3.32)
0.505
800-1000
140
38-39
92
1231
1580
398
220-240v, 50hz
single
1.73-2.20
6
3
guF-rd3Lossnay Outdoor Air Processing Indoor Unit
1. nominal condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume.Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB.Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB.
2. uK condition:Summer: Indoor 21ºC, Outdoor 27ºCWinter : Indoor 21ºC, Outdoor -1ºCWB
3. The figures in ( ) indicates the heat recovery at Lossnay core.
4. The current, input and efficiency are based on the above air volume.
5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch).
6. Specifications may be subject to change without notice.
The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.
� a combination of a lossnay & city multi indoor in a single unit
� air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the city multi air conditioning system
� the ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs
� heat recovery helps to save energy - a benefit that’s not only good for the environment, but also great for cutting energy costs
� Free cooling is also available should outdoor conditions be suitable
Technical Information
Page 230
attention
)wercs 1R( niarD
xob lortnoC
teltuo retaW)wercs 4/3CR(
lenap ecivreS
tinu roodtuo fo epip noitcennoC )diuqiL(
ø >dezarB< 88.51
ø dezarB< 25.9 >
tinu roodtuo fo epip noitcennoC)saG(
telni retaW)wercs 4/3R(
525)hctip gnitnuoM(
(Mou
ntin
g pi
tch)
205
800
300
054
005
55
53
53
19
19431
480
64
6014
0
100
191
8016
5
102
54
481
411
PWFY-P100VM-E-BU
PWFY-P100/200VM-E-AU
upper view >
side view >Front view >
tnioj noisnapxE eht esU:002Pseirossecca fo
)wercs 1R( niarD
ø >dezarB< 25.9
teltuo retaW)wercs 4/3CR(
telni retaW)wercs 4/3R(
:001P ø >dezarB< 88.51:002P ø dezarB< 50.91 >
tinu roodtuo fo epip noitcennoC )saG(
tinu roodtuo fo epip noitcennoC )diuqiL(
xob lortnoC
lenap ecivreS
525( hctip gnitnuoM )
054
(Mou
ntin
g pi
tch)
300
800
205
005
19
19
53
55
53
480
102
602
431
411
100
191
64
60140
8016
5
54
cit
y m
ult
iR
ange
Pw
Fy-P
Dimensions
Page 233
upper view >
side view >Front view >
PwFy-PVRF Heat Pump Boiler
Technical Information
Page 232
PWFY-P
model reFerence
caPacity heating (nominal)
cooling (nominal)
heating (uK)
Power inPut (kw)
comPatible outdoor / condensing units
reFrigerant charge (kg) high temp circuit
PiPe siZe (mm) (in) gas
liquid
water
drain
noise (dba)
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
running current (a)
Fuse rating (bs88) - hrc (a)
mains cable no. cores
water Flow rate m3/h
PWFY-P100VM-E-BU
12.5
-
12.5
2.48
Pury / PQry
1.1 (r134a)
15.88 (5/8")
9.52 (3/8")
19.05 (3/4”)
ø32 (1 1/4”)
44
60
450
300
785 (800)
220-240v, 50hz
single
10.66
25
3
0.6-2.15
PWFY-P200VM-E-AU
25.0
22.4
20.8
0.015
Puhy / PQhy / Pury / PQry
-
19.05 (3/4")
9.52 (3/8")
19.05 (3/4”)
ø32 (1 1/4”)
29
38
450
300
785 (800)
220-240v, 50hz
single
0.063
6
3
1.2-4.3
PWFY-P100VM-E-AU
12.5
11.2
10.4
0.015
Puhy / PQhy / Pury / PQry
-
15.88 (5/8")
9.52 (3/8")
19.05 (3/4”)
ø32 (1 1/4”)
29
35
450
300
785 (800)
220-240v, 50hz
single
0.063
6
3
0.6-2.15
the mitsubishi electric booster unit (PwFy-P100vm-e-bu) can achieve a flow temperature of 70ºC and is anideal solution for providing a hot water supply to commercial buildings in an energy efficient manner.
Heat pump technology works by extracting heat from the air and upgrading it to heat a building. This process in itself is energy efficient, howeverwe can take this a step further by using heat recovery. Heat recovery technology taps into and utilises otherwise wasted heat energy, extractedfrom areas of a building that require cooling, providing heating for hot water almost for free. Recovering the heat in this manner maximisesthe efficiency of the system all year round, therefore increasing energy savings and lowering running costs.
Taking full advantage of heat recovery technology, the 12.5kW PWFY booster unit upgrades the heat pump energy to higher temperaturesrequired to achieve 70ºC water temperatures. This is possible using the first ever VRF cascade refrigeration system between R410A andR134a refrigerant.
The benefit of having air conditioning as well as a hot water supply from a single system means that the unit is suitable for a variety of applications. Offices, hotels, gyms, restaurants etc are typical examples of buildings that already have an air conditioning system in place. Providing the essential hot water supply to these applications is a simple addition of the booster unit to the existing air conditioning system. It is a perfect solution that allows inconveniences that arise when installing gas boilers such as gas grid connection costs, meter installation and maintenance costs to be eliminated. Further there is a reduction in running costs and carbon emissions due to the high efficiency of these units over gas boilers.
The Mitsubishi Electric air to water heating units (PWFY-P100/200VM-E-AU) can achieve flow temperatures of 45ºC in heating and 10ºC in cooling, making them perfect forapplication on underfloor heating/cooling systems.
� can be used in conjunction with cmb-Pw202v-J to allow a 200% heat recovery index� uses the Par-w21maa controller
note: The PWFY-P200VM-E-AU will require 2 expansion joints
cit
y m
ult
iR
ange
vr
F Ph
v d
xe
Hea
t Pu
mp
Air
Cur
tain
Page 235
AIR CURTAIN vrF Phv1000/1500/2000r dxe
Dimensions
AIR CURTAIN vrF Phv1000/1500/2000 dxe
rear view >
upper view >
side view >
rear view >
upper view >
side view >
vrF Phv dxe Heat Pump Air CurtainAir Curtain System
Page 234
VRF PHV DXE - RECESSEDmodel reFerence
dimensions (mm) (wxdxh)
suPPly (50hz)
heat outPut (kw)
loading (amps)
velocity (m/s)
air volume (m3/h)
weight (kg)
noise db(a) @ 3m
max. mounting height (m)
outdoor unit model
VRF PHV1500R DXE HO
1650x436x296
415v*1
15.1
12.7*1
9
2600
67
58
3.5
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV2000R DXE LO
2240x436x296
415v*2
16.4
15.7*2
9.5
3300
85
59
3.5
Pumy / Puhy / Pury / PQhy / PQry
Technical Information
VRF PHV DXE - FREE STANDINGmodel reFerence
dimensions (mm) (wxdxh)
suPPly (50hz)
heat outPut (kw)
loading (amps)
velocity (m/s)
air volume (m3/h)
weight (kg)
noise db(a) @ 3m
max. mounting height (m)
outdoor unit model
VRF PHV1500R DXE LO
1650x436x296
415v*1
10.6
12.7*1
9
2500
66
58
3.5
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV1000R DXE HO
1150x436x296
415v*1
9
7.8*1
9
1400
45
56
3.5
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV2000R DXE HO
2240x436x296
415v*2
21.4
15.7*2
9
3130
88
59
3.5
Puhy / Pury / PQhy / PQry
VRF PHV1500 DXE HO
1746x377x255
415v*1
15.1
12.7*1
9
2600
60
58
3.75
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV2000 DXE LO
2296x377x255
415v*2
16.4
15.7*2
9.5
3300
78
59
3.75
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV1500 DXE LO
1746x377x255
415v*1
10.6
12.7*1
9
2500
59
58
3.75
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV1000 DXE HO
1196x377x255
415v*1
9
7.8*1
9
1400
39
56
3.75
Pumy / Puhy / Pury / PQhy / PQry
VRF PHV2000 DXE HO
2296x377x255
415v*2
21.4
15.7*2
9
3130
80
59
3.75
Puhy / Pury / PQhy / PQry
notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
In collaboration with Thermoscreens®, Mitsubishi Electric have developed a range of air curtains that are able to beconnected to our City Multi VRF systems, as opposed to the more traditional direct electric method associatedwith air curtains.
� reduced co2 emissions
� reduced running costs
� inverter technology (does not waste energy)
� range of different sizes to suit every application
� allows open door policy in retail outletswhilst being energy efficient
� clean environment - protection from dust, fumes etc
� comfortable climate for customers
� easy to install and maintain
� heat recovery possible, optimising energy use
INDOOR UNIT vrF Phv2000 nt
Dimensions
vr
F Ph
v n
tSe
nsib
le C
oolin
g C
hille
d W
ater
Uni
t
rear view >
upper view >
Page 237
side view >
upper view >
vrF Phv ntSensible Cooling, Chilled Water Wall Mounted Indoor Unit
In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our City Multi VRF systems via the PWFY-P200VM-E-AU heat pump boiler. This unit offers 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications.
� shF of 1 and capacity validated by 3rd party assessment (bsria)
� reduced co2 emissions
� reduced running costs
� inverter technology (does not waste energy)
� easy to install and maintain
� ideal for small to medium size server rooms / laboratories
� no 3rd party humidifier is required
� Par-w21maa controller included
� ideal for heat recovery applications - use with the water system connection box (wcb)
on page 240 to achieve full heat recovery potential
Page 236
Technical Information
VRF PHV NT - indoor units
model reFerence
dimensions (mm) width
depth
height
caPacity (kw) cooling
shF
electrical suPPly
Phase
loading (a)
velocity (m/s)
air volume (m3/h)
weight (kg)
noise (dba) @ 3m
water volume Flow rate (m3/h)
hydraulic resistance (kPa @ 3.18 m3/h)
hydraulic resistance oF PwFy-P200vm-e-au (kPa @ 3.18 m3/h)
water volume oF coil (litres)
water volume oF heat exchanger in PwFy-P200vm-e-au (litres)
outdoor unit model
VRF PHV2000 NT
2296
377
255
12.0
1.0
220-240v, 50hz
single
2.7
9
2885
90
59
3.18
36
38*1
5.1
2.09
Puhy / Pury / PQhy / PQry
notes: For use with a Mitsubishi Electric PWFY-P200VM-E-AU water cooling unit as part of a VRF system. Water flow temperature from the PWFY-P is to be set to 10ºC (cannot be set lower)Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA tests. *1 Without strainer.
C. 1
50m
in.
for p
ipes
255
295
168
36
cit
y m
ult
iR
ange
PwFy-P (not included)
CMB-P104, 105, 106V-G1
CMB-P108, 1010, 1013, 1016V-GA1/HA1
CMB-P104, 108V-GB1
side view >upper view >
CMB-P1016V-HB1
a bcmb-P104v-gb1
cmb-P108v-gb1
3
7
180
420
cit
y m
ult
iR
ange
bc
cont
rolle
rs
Dimensions
side view >upper view >
side view >upper view >
side view >upper view >
Page 239
cmb-P104v-g1
cmb-P105v-g1
a b
3
4
180
240
cmb-P106v-g1 5 300
a b
cmb-P108v-ga1
cmb-P1010v-ga1
7
9
420
540
cmb-P1013v-ga1 12 720
cmb-P1016v-ga1/ha1 15 900
bc controllers
BC CONTROLLERSmodel reFerence
number oF connections
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
Power inPut (Kw)
running current (a)
Fuse rating (bs88) – hrc (a)
mains cable no. cores
CMB-P104V-G1
4
24
648
432
284
220-240v, 50hz
single
0.085
0.36
6
3
CMB-P106V-G1
6
28
648
432
284
220-240v, 50hz
single
0.123
0.52
6
3
CMB-P105V-G1
5
27
648
432
284
220-240v, 50hz
single
0.104
0.44
6
3
Technical Information
At the heart of both the R2 and WR2 Series, the BC controller makessimultaneous heating and cooling possible. It has the inherent ‘intelligence’ to be the system’s decision-maker.
� transferring energy around the system
� drawing on energy from the heat source units/outdoor units
� directing energy as requested by the individual indoor units
� instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements
� allows unique 2-pipe heatrecovery application
� hic circuit for improved efficiency
� new brazed connections
note: CMB-P-V-G1 units are for use with PURY-(E)P200-350 YJM-A & PQRY-P200-300YHM-A units only.
SLAVE BC CONTROLLERSmodel reFerence
number oF connections
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
Power inPut (Kw)
running current (a)
Fuse rating (bs88) – hrc (a)
mains cable no. cores
CMB-P104V-GB1
4
22
648
432
284
220-240v, 50hz
single
0.076
0.32
6
3
CMB-P1016V-HB1
16
55
1098
432
284
220-240v, 50hz
single
0.301
1.26
6
3
CMB-P108V-GB1
8
32
648
432
284
220-240v, 50hz
single
0.151
0.63
6
3
MASTER BC CONTROLLERSmodel reFerence
number oF connections
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
Power inPut (Kw)
running current (a)
Fuse rating (bs88) – hrc (a)
mains cable no. cores
CMB-P108V-GA1
8
43
1110
520
289
220-240v, 50hz
single
0.161
0.68
6
3
CMB-P1013V-GA1
13
55
1110
520
289
220-240v, 50hz
single
0.255
1.07
6
3
CMB-P1016V-HA1
16
69
1110
520
289
220-240v, 50hz
single
0.312
1.30
6
3
CMB-P1010V-GA1
10
48
1110
520
289
220-240v, 50hz
single
0.198
0.83
6
3
CMB-P1016V-GA1
16
62
1110
520
289
220-240v, 50hz
single
0.312
1.30
6
3
Page 238
note: CMB-P-V-GA1 units are for use with PURY-(E)P200-650Y(S)JM-A(1) & PQRY-P200-600Y(S)HM-A units only. CMB-P1016V-HA1 unit is for use with PURY-(E)P700-900YSJM-A units only.
CMB-PW202V-J
side view >
upper view >
cit
y m
ult
iR
ange
wat
er c
onn
ection
box
(wc
b)
Dimensions
Front view >
Page 241
water system connection box (wcb)
WCBmodel reFerence
comPatible outdoor / condensing units
weight (kg)
dimensions (mm) width
depth
height
electrical suPPly
Phase
Power inPut (Kw)
running current (a)
Fuse rating (bs88) – hrc (a)
mains cable no. cores
CMB-PW202V-J
Pury-(e)P200-350yJm-a / PQry-P200-300yhm-a
20
648
432
284
220-240v, 50hz
single
0.024
0.10
6
3
Technical Information
By utilising a WCB, a system can be sized for the cooling load of a communications room and then use the delivery of cold waterfrom a PWFY to achieve this. The system can then benefit from full heat recovery of up to 200% by connecting a second PWFY inheating mode that can deliver sanitary hot water or hot water for space heating elsewhere in the building.
Typically the outdoor unit of a system is sized to match the internal load. For a communications room there is a continuous coolingload and under normal circumstances all the heat is wasted to the outside.
Following the success of PWFY, this new low cost branch controller allows simple heat recovery between 2 ports, onebeing heating only with PWFY, the other being heating or cooling with PWFY or standard indoor units. A key factorwith the WCB is the ability to allow 200% connectable index to the system.
� total heat recovery, transferring all energy around the system
� 200% connectable heat recovery index for optimum efficiency, flexibility andcost savings (130% when connecting with standard indoor units)
� energy saving mode available (longer heat up time, but with a15% coP improvement on standard control)
� installation cost and time savings
� connectable to both bu and au PwFy models
Page 240
example 2: 130% connection with hot water and cooling/heating indoor units
outdoor heat recovery unit (size 200)
wcb
PwFy-P200au (heating)to underfloor heating
example 1: 200% connection with continual heating only and cooling only Ports
PwFy-P200au (cooling)to third party comms room unit
PwFy-P100bu (hot water) to tank
3 x PeFy-P50vma(cooling/heating)restaurant
outdoor heat recovery unit (size 200)
wcb
note: 100% if only in heating
cit
y m
ult
iR
ange
air
han
dlin
g u
nit
cont
rolle
rs /
acc
esso
ries
accessories / optional extras
CMY-Y102S-G2CMY-Y102L-G2CMY-Y202-G2CMY-Y302-G2CMY-Y62-G-ECMY-Y100VBK2
CMY-Y200VBK2CMY-Y300VBK2CMY-RP100VBKCMY-RP200VBKCMY-R100VBKCMY-R200VBKCMY-R100XLVBKCMY-R200XLVBKCMY-Q100VBKACH1ACH2PAC-CN32WHMC-UK
PLP-6BASLP-2AAWPLP-6BALMPLP-6BAJPAC-SA1ME-EPAR-SA9FA-ES70E40714
CMP-40VLW-CCMP-63VLW-CCMP-100VLW-CCMP-125VLW-CPAC-KH11OF
PMP-40BMW
PAC-KE04DM-FPAC-KE88LAFPAC-KE89LAFPAC-KE85LAFPAC-KE80TB-FPAC-KE140TB-FPAC-KE250TB-F
CMY-R160-J1CMY-S202-J
PAC-SE41TS-E
PAR-W21MAATHERM-10M
outdoor units
4-way blow cassette units
2-way blow cassette units
1-way blow cassette units
ceiling concealed ducted units
bc controllers
indoor units
vrF heat Pump boilers
A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 8dBA noise level reduction from standard.
For supply and / or installation please contact
ambient acoustics on 01934 712802
acoustic Kits for PUHY and PURY Series units
- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units- Branch Pipe (Joint) for size 201-400 - total capacity of indoor units- Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650- Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900- Branch Pipe for 2 branches (PUMY)- Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSJM-A /
PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A- Twinning Kit for PUHY-P700-900YSJM-A- Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSJM-A / PQHY-P650-900YSHM-A- Twinning Kit for PUHY-RP400-650YSJM-B- Twinning Kit for PUHY-RP700-900YSJM-B- Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-600YSJM-A- Twinning Kit for PURY-P700-800YSJM-A- Twinning Kit for PURY-EP650-700YSJM-A- Twinning Kit for PURY-P850-900YSJM-A- Twinning Kit for PQRY-P400-600YSHM-A- PQFY Auto-Changeover controller- VRF AHU Interface (for use with 24v AC signals)- Energy monitoring connector
- Grille for PLFY-P-VBM-E- Grille for PLFY-P-VCM-E2- Grille and infra-red controller for PLFY-P-VBM-E- Grille with filter lowering function for PLFY-P-VBM-E- ‘I -See Sensor’ corner panel for PLFY-P-VBM-E- Infra-red signal receiver for PLFY-P-VBM-E- Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E
- Grille for PLFY-P20-40VLMD-E- Grille for PLFY-P50-63VLMD-E- Grille for PLFY-P80-100VLMD-E- Grille for PLFY-P125VLMD-E- OA duct flange for PLFY-P20-100VLMD-E
- Grille for PMFY-P-VBM-E
- Drain lift-up mechanism for PEFY-P-VMH-E- Long life filter for PEFY-P80VMH-E- Long life filter for PEFY-P100-140VMH-E- Long life filter for PEFY-P250VMH-E- Filter box for PEFY-P80VMH-E (necessary when long life filter is used)- Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)- Filter box for PEFY-P250VMH-E (necessary when long life filter is used)
- Joint pipe- Cover cap for CMB-PW202V-J
- Remote sensor
- Controller- Thermistor (10m cable)
Air Handling Unit Controller
PAC-AH-M-J - AHU CONTROLLERmodel reFerence
air handling unit siZe
allowed heat exchanger caPacity (kw) - heating
allowed heat exchanger caPacity (kw) - cooling
allowed heat exchanger volume (cm3)
reFerence air Flow rate (m3/h)*3
standard evaPorator Path number*1
dimensions (mm) width
( ) = inc mountings depth
height
weight (kg)
PiPe siZe mm(in) gas
liquid
aPPlicable outdoor units
Puhy-P y(s)Jm-a
Puhy-eP y(s)Jm-a
Puhy-hP y(s)Hm-a
Puhy-rP y(s)Jm-b
PQhy-P y(s)Hm-a
PAC-AH125M-J
P100
10.0 - 12.5
9.0 - 11.2
1500 - 2850
2000
4 - 5
328
104 (122)
378 (420)
5
15.88(5/8”)
9.52(3/8”)
PAC-AH125M-J
P125
12.5 - 16.0
11.2 - 14.0
1900 - 3550
2500
4 - 5
328
104 (122)
378 (420)
5
15.88(5/8”)
9.52(3/8”)
PAC-AH140M-J
P140
16.0 - 18.0
14.0 - 16.0
2150 - 4050
3000
5 - 6
328
104 (122)
378 (420)
5
15.88(5/8”)
9.52(3/8”)
PAC-AH250M-J
P200
18.0 - 25.0
16.0 - 22.4
3000 - 5700
4000
6 - 10
328
104 (122)
378 (420)
5
19.05(3/4”)
9.52(3/8”)
PAC-AH250M-J
P250
25.0 - 31.5
22.4 - 28.0
3750 - 7100
5000
8 - 10
328
104 (122)
378 (420)
5
22.22(7/8”)
9.52(3/8”)
PAC-AH500M-J
P400*2
40.0 - 50.0
36.0 - 45.0
6000 - 11400
8000
16 - 20
328
104 (122)
378 (420)
5
28.58(1 1/8”)
12.7(1/2”)
PAC-AH500M-J
P500*2
50.0 - 63.0
45.0 - 56.0
7500 - 14200
10000
16 - 20
328
104 (122)
378 (420)
5
28.58(1 1/8”)
15.88(5/8”)
note: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH = 5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB*1 When the diameter of the heat exchanger tube is ø9.52. *2 P400 and P500 are not compatible with PURY and PQRY. *3 If using in combination with standard indoor units, then these figures do not apply.
m-net wiring thermistor wiring
Piping
air handling unit (field supplied)
controller (field supplied)
outdoor unit (mitsubishi electric)
Technical Information
The Air Handling Unit Controller is an interface to allow connection to third party manufacturer equipment.
Mitsubishi Electric City Multi outdoor units can be used with thisinterface box, creating and ideal solution when a unique air handlingunit is required. The Air Handling Unit Controllers are supplied withLEV expansion device(s).
� discharge or return air temperature control
� temperature set point by control 0-10vdc� auto mode available for ease of application� error input� iP2x rated (only for internal use)
air handling unit controller (mitsubishi electric)
220-240v, 50hz Power supply
Pac-ah-m-J
example:
Pury-P y(s)Jm-a
Pury-eP y(s)Jm-a
Pury-rP yJm-b
PQry-P y(s)Hm-a
Page 243Page 242
Lossnay Total Heat Exchangers
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
The secret of the Lossnay system liesin the cross flow, plate fin structure of the heat exchange unit.A diaphragm made of specially processed paper fully separatesinlet and exhaust air supplies, ensuring that only fresh air isintroduced to the indoor environment.
The microscopically small pores of the diaphragm havebeen made even smaller, decreasing the rate at which watersoluble gases such as Ammonia and Hydrogen pass through.Further, a new specially processed paper used to make thediaphragm has been developed with high moisture permeabilitycharacteristics.
This aids in the transfer of moisture and improves theeffectiveness of shielding unwanted gases, resulting in highly efficient energy transfer.
Improvements to the Lossnay
Fresh airinto building
(Supply Air)
Stale airremoved from
building (Return Air)
Stale dirty indoor air (Exhaust Air)
Fresh air introduction(Outdoor Air)
Outdoors Indoors
Fresh air supply to the room
Stale room air extracted
Stale exhaust air
Fresh air from outside
Heat exchange unit(Lossnay core)
Page 247
Poor air quality can be attributed to many problems arising in theworkplace or in the home. It is believed to contribute to a significantloss in productivity, low morale and higher rates of sickness amongstmany employees. The object of providing good ventilation alongsideair conditioning in residential and commercial buildings is to provideconditions under which people can live and work in comfort and safety.
Developed and refined over the past 35 years, the Lossnay system hasperfected the recovery of energy that would have otherwise been wasted. The units reduce overall energy costs by extracting stale air and then recoveringthe heating or cooling energy to either warm or cool incoming fresh air.By utilising this energy, the Lossnay system can save up to 30% on initial capital costsof heating and cooling plant by reducing the load of the occupied space, resulting inthe need for a smaller heating and/or cooling system.
Page 246
TheSecret of
the LossnaySystemExcellent Air Quality
and Unbeatable HeatExchange Efficiency
Simple andEffective
Using a Lossnay LGH-100RX5 in the winter example above, 8.2kW of heat is recovered per hour from the extracted air.
Effective VentilationLossnay’s simultaneous air exhaust/supply provides effectiveventilation. Conventional ventilators (i.e. extract propeller fans)do not work effectively within air tight buildings because of thenegative air pressures involved.
Good Energy RecoveryTotal heat (sensible and latent) recovery provides acomfortable air temperature within the room. The energysaved by using Lossnay contributes towards lowering theheating or cooling requirement within the building, therefore reducing the energy requirement and running costs.
Free Cooling “By-pass”Function (LGH series)When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay providesfresh outdoor cool air to reduce the indoor air temperature.
Good Sound AttenuationAs the Lossnay core is made of paper and the permeable holesare small, the Lossnay core provides outstanding soundproofingproperties and is appropriate for sound proof rooms.
Part L2 BuildingRegulationsWith the introduction of Part L2 (Part J in Scotland), newbuilding design is changing to become more airtight, as well asenergy efficient. The need for fresh air has remained the samehowever and thus poses new challenges for modern design.Lossnay fully meets these challenges due to its basic principaland its efficient heat recovery.
Page 249
Main Features ofLossnay
Page 248
Total HeatRecoveryConcept
Operationin winter
4°CStale warm air (exhaust)
0°CFresh cool air (outdoor air)
20°CStale warm air
(indoor air)
16°CFresh warm air
(indoor supply air)
Heating unit
Operationin summer
25.6°CStale cool air (exhaust)
27°CFresh hot air (outdoor air)
21°CStale cool air (indoor air)
22.4°CFresh cool air
(indoor supply air)
Coolingunit
Ambient Temperature - London 2006, 8am - 6pm
Over 58% of the time between 8am-6pm,the temperature in London was between8ºC and 20ºC, allowing free cooling when the air conditioning setpoint was 21ºC incooling mode. If the setpoint is higher, free cooling is increased.
Lossnay fan speed button is incorporated within the standard PAR-30MAA and PAR-F27MEA controllers
Above example:
One LGH25RX5 serving one PLA-RP71BA. Room size 7m x 7m,140w/m2 heat load. 7 people per room, 10litres/person of fresh air to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements. Free cooling is not available below 8ºC when interlocked with Mr Slim or City Multi units.
Lossnay units can work either on their own to provide fresh air into a room, or in combinationwith Mr Slim or City Multi ceiling cassettes and ducted units.
When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning unit are connected by a two core communication cable, they can worktogether to optimise both comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning requires, then utilising the outside temperature to help achieve the required temperature either by free cooling or heat recovery.
When using Lossnay in conjunction with air conditioning the heating and cooling loads can be reduced significantly, reducing therunning costs by up to 30% compared with air conditioning systems without heat recovery systems.
The graph shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m. The point tonote is the amount of free cooling available duringthese hours, as well as the heat recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year round solution for providing fresh air.
Page 251
Lossnay Working in Conjunctionwith Air Conditioning
Page 250
Free Cooling was available in
London over 58%of the time in
2006
Multi-Ventilation ModeEnables the appropriate supply/exhaust balance to be selected to suit usage,environment and location.
All LGH-RX5-E models feature the "Multi-ventilation Mode,"which allows the air supply/exhaust balance to be varieddynamically to suit the usage environment and location.Modes can be selected easily by setting the connectorson the circuit board.
* "High" can be further set to "Extra high" using the dip switch.
Normal Office Small Office or Building Industrial Areas
Power air supply& air exhaust
Most widely-used pattern formingthe basis for traditional ventilationdesign. This allows the most efficientventilation while maintaining the airsupply/exhaust balance. The optimumventilation rate can be maintained byselecting the Power air supply/exhaustmode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the controlswitches can be set to "High" to runin Power air supply/exhaust modewhen a large number of people are in the office, then switched to "Low"to run in Energy-saving ventilationmode late at night or on holidayswhen there are few people present.
In smaller offices or buildings, theremay be insufficient air supply to themain rooms or offices due to theexcessive exhaust via extractor fanslocated in toilets or kitchen areas.Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.
In locations such as industrial working areas, dirty air must beexhausted swiftly. Setting the Power air exhaust mode with the air supply switch on "Low" and the air exhaust switch on "High" (or "Extra high") on the main unitallows efficient extraction of fumesand odours. Maintaining the area at a negative air pressure alsoprevents dirty air from spreading to surrounding areas.
Power air supply Power air exhaust
Power air supply/exhaust mode
Power air supply mode
Power air exhaust mode
Energy-saving ventilation mode
Ventilation Mode
High
High
Low
Low
SupplyAirflow
High
Low
High
Low
Exhaust Airflow
Hyper Eco CoreLGH-RX5-E and LGH-RSDC-E Lossnay units feature the newly developed “Hyper Eco Core”, which uses non-porous, ultra-thin film toachieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and are approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically increased and enthalpy heatexchange greatly improved.
Consists of a two-layer constructionusing a specially processed materialmade of a preferential permeable film on a porous base material. This provides moisture permeabilityand air barrier properties, but the two-layer construction makes a certain thickness unavoidable.
Consists of a specially processedstructure based on a single-layer, non-porous, ultra-thin film material.Moisture exchange (water vapourtransmission) is promoted by thespecial film, which increases theaffinity for moisture (the thinner the film, the higher the permeability).The non-porous ultra-thin filmmaterial acts as a barrier against air leakage.
Use
Hyper Eco Core material
Previous Mitsubishi Electric material
Photocopier paper
Dictionary paper
The thinnest paper used in regularprinting is 51µm thick (used in dictionaries) and the material of theHyper Eco Core is approximately half the thickness of this.
Comparison of material used in Hyper Eco Core (25µm ultra-thin film) with regular paper
Comparison of new and old Lossnay Core cross-sections
Previous Lossnay Core New Hyper Eco Core
Porous partition plate Non-porous film partition plate
120µm 25µm
Ducts can be connected in two different directions to the outdoor ventsthanks to collars and aperture plates that can be interchangeably placed intwo different positions.
This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both the planning andinstallation of Lossnay units that much simpler.
Standard installationInstallation with duct
direction changed
A space is necessary to prevent the influx of rainwater.
Collar Aper ture Plate Exchangeable
Can beinstalled closeto the surfaceof the wall.
Changing the duct direction
Connect Ducts in Two DifferentDirections (Outdoor vents)
In addition to the conventional fan speeds, an ExtraLow mode has been added to provide a moredynamic range of air volume settings. This providesversatility in a variety of installation environments,yielding better energy conservation.
Extra Low mode (LGH-RX5-E)CO2 Sensor
Thickness
25µm
120µm
100µm
51µm
Lossnay systems allow you to measureCO2 density (via an independent, 3rd par tyCO2 sensor) and thereby control theamount of fresh air supplied to a building. By connecting a CO2 sensor to the Lossnayunit, the system will switch fan speedsautomatically depending on the CO2 level.
Page 253Page 252
Providing efficient ventilation whilemaintaining air supply/exhaust balance...
Using Lossnay compensates for usingextractor fans...
Priority on air exhaust...
Many office buildings today are heavily insulated, air-tight structureswith little or no natural ventilation. The unnatural environmentcreated by air conditioners without added ventilation is a breedingground for bacteria. Factor this in with the accumulation ofpollutants and odours in the form of formaldehyde, pollen, dust,carbon dioxide and the necessity of ventilation becomes evermore apparent. In fact, poorly ventilated buildings can give rise toSick Building Syndrome, a malady that is known to cause headaches,sore eyes, itching and loss of concentration.
This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reducedproductivity of the workforce. Fresh air, effectively ventilatedthroughout the building is therefore essential to the overall qualityof working life.
Off icesFresh air - improving the overallquality of working life
Restaurants Schools
The atmosphere of a restaurant is crucial to securing andretaining customers. Cleanliness is the key to an attractiveatmosphere and restaurants devote significant effort to ensuringtheir premises are as such. Sanitation and cleanliness, however,are not enough. No matter how clean a restaurant may look, ifthere are bothersome odours lingering in the air, all those effortsgo to waste and the restaurant's clean image is tarnished.
For these reasons, Lossnay’s superior ventilation capabilitiesensure that every breath is a fresh one and a pleasantenvironment is maintained for guests at all times. Lossnay also keeps owners happy with its remarkable heat recoverytechnology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy costs.
A restaurant can never be tooclean and its air never too fresh
Creating the best possible environmentfor our children to succeed
Children deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good aschool's curriculum, no matter how positive and enthusiastic theteacher, a child who does not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where largenumbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate,decreasing the levels of oxygen that are vital for alertness and concentration.
This is especially true during the winter months when windowstend to remain closed. Lossnay ventilates fresh outdoor air intoclassrooms to replenish the supply of oxygen and expels notonly carbon dioxide, but also other pollutants and odours thatinevitably sully the air.
Lossnay works to remove stale air and supplyfresh, clean air free of the odours associated
with cooking, cigarettes and the people working and dining.
Change in room temperature is kept to a minimum during ventilation thanks to the
heat-recovery function.
The Lossnay operate very quietly, so those inthe midst of enjoying their meals will not be
bothered by any excess noise.
A large array of Lossnay sizes are available tomatch the layout of just about any restaurant.
The continuous influx of fresh, outdoor air andthe exhaust of stale, indoor air ensure that theindoor oxygen level is maintained at just the
right balance for comfort and health.
Occupants have the luxury of breathing freshair at all times, even in highly air-tight buildings.
Lossnay's sound attenuation qualities preventoutside noise from penetrating into the room,
helping to maintain a quiet environment forproductive study.
Heat-exchange technology prevents fluctuationsin temperature creating significant energy
savings when either heating or cooling a room.
If it’s Lossnay If it’s Lossnay
%3.25
Others: no response
Promotion of waste prevention: 5.4%
Improvement in atmosphere: 6.5%
Reduction of time required forfood to reach the table: 12.0%
Improvement in employees attitude towards customers: 20.5%
Improvement in overallcleanliness
1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan)
What would you most like to see improved in restaurants?
Incr
ease
d re
spir
atio
nan
d pu
lse
21
15
10
5
0 Nor
mal
air
Safe
ty m
inim
um
O2
Con
cent
ratio
n (%
)
Diz
zine
ss, n
ause
a,lo
ss o
f mus
cle
stre
ngth
(pr
ecur
sors
of d
eath
)
Pale
ness
of s
kin,
vom
iting
,U
ncon
scio
usne
ss
Com
atos
is(d
eath
in 8
min
)
Con
vulsi
ons,
resp
iratio
nst
ops,
deat
h
21 %18 %
16 %
12 %10 %
8 %
6 %
O2 Concentration and Deficiency
2
Page 255Page 254
Occupants havethe luxury of
breathing fresh air at all times, even in
highly air-tight buildings
Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building,effectively ventilating even fully airtight structures.
Multiple split-type units operate independently of one another, simplifying system set up and
ensuring a layout that optimally matches nearly any office design.
Lossnay operation can be interlocked withair-conditioning system operation.
Heat that is commonly lost due to ventilation is collected and reused thanks to the
Lossnay Core, reducing an air conditioners energy load and cutting operating costs.
If it’s Lossnay
The Unbeatable
LossnayThe Lossnay allows the extraction ofstale air and efficient recovery of heating or cooling energy to treat incomingfresh air. Whatever your environment,it’s simple to improve it with Lossnay.
Page 256
Total Heat Exchangers Residential Model
LGH-RSDC-E DC Lossnay Model
LGH-RX5-E Commercial Series
258
260
262
Page 257
Simple technologyat its best
Many of our systems are registered on the Energy Technology Listand hence qualify for 100% first year enhanced capital allowances.
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
For further information please go to www.eca.gov.uk
Contents
VL 100U
Tota
l Hea
t Exch
ange
rsR
esid
entia
l Mod
elLo
ssnay
Ran
ge
Dimensions
Page 259
Residential Model
Total Heat Exchangers
LOSSNAYMODEL REFERENCE
ELECTRICAL POWER SUPPLY
PHASE
POWER CONSUMPTION (W) Low
High
AIRFLOW (m3/h) Low
High
NOISE (dBA) Low
High
Low
High
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
DUCT SIZE (mm)
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
RESIDENTIAL WALL- MOUNTED VL 100U
220-240V, 50Hz
Single
23
26
65
105
29.5
39
77
70
6.5
620
168
265
2xØ75
6
3
TEMPERATURE
EXCHANGE
EFFICIENCY (%)
Technical Information
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss.
� Effective fresh air ventilation
� Efficient recovery of heating/cooling energy
� Good sound attenuation
� Reduces heating costs
Page 258
LGH-50RSDC-E
LG
H-5
0R
SDC
-ED
C L
ossn
ay M
odel
Lo
ssnay
Ran
ge
Dimensions
Page 261
Front View >
Upper View >
Rear View >
Left Side View > Right Side View >
Lossnay-5-FSC Interface
� Control up to 16 DC Lossnay units
� Automatic fan speed control based on CO2 level (5 speeds)
� Interlock with a PIR sensor or switch
� Interlock with a CO2 sensor or BEMS (0-10v DC)
� Dimensions (WxDxH) mm: 160x80x120
DC Lossnay Model
LGH-RSDC-E
LOSSNAYMODEL REFERENCE
ELECTRICAL POWER SUPPLY
STARTING CURRENT (A)
VENTILATION MODE
FAN SPEED
INPUT POWER (W)
AIRFLOW (m3/h)
AIRFLOW (l/s)
EXTERNAL STATIC PRESSURE (Pa)
NOISE (dBA)
TEMPERATURE EXCHANGE EFFICIENCY (%)
Heating
Cooling
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
DUCT SIZE (mm)
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. Cores
LGH-50RSDC-E
220-240V, 50Hz
2
LOSSNAY BYPASS
1
172
445
124
75
31
75
68.5
65.5
2
92
340
94
45
26
80
73.5
71
3
42
240
67
25
21
84.5
78
76
4
23
160
44
10
18
87.5
81.5
79.5
5
14
100
28
5
18
90
83.5
82.5
POWER
279
520
144
102
35
-
-
-
45
1099 + 73
898
302
200
6
3
1
172
445
124
75
31
-
-
-
2
92
340
94
45
26
-
-
-
3
42
240
67
25
21
-
-
-
4
22
160
44
10
18
-
-
-
5
14
100
28
5
18
-
-
-
Technical Information
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. This model is also suitable for a number of non-residential applications such as schools.
� Effective fresh air ventilation
� Efficient recovery of heating/cooling energy
� Good sound attenuation
� Reduces heating costs
� Low power consumption with 5 variable fan speeds
� New “Hyper Eco Core” facilitating improved humidity penetration
� By-pass mode for ‘free cooling’. Including new power mode to supply a greater volume of fresh, cool air - for instance during summer nights
� SAP Appendix Q eligible
� Optimise the fan speed based on CO2 level using the Lossnay-5-FSC interface
Page 260
ENTHALPY
EXCHANGE
EFFICIENCY
LOSSNAY core
Air exhaust fan
Position where duct direction change is possible
By-pass damper plate
Maintenance cover
Control box
Air supply fan
Ceiling suspension fixture
B
150
~250
More
than 6
00
High efficiency filter(sold separately)attachment position
A
change is possible
C
Air filters (EU-G3)
D
E
cable opening
Core, air filter, High-Efficiency filter, fan,Maintenance space
(4-13x20 oval)
EA (exhaust air outlet)
(outside air intake)OA
(return air)RA
(supply air)SA
Power supply
Position where duct direction
Inspection opening
MODEL REFERENCE
LGH-150RX5-E
LGH-200RX5-E
A
1004
1231
B
690
917
C
1045
1272
LGH-15RX5-E to LGH-200RX5-E
Lossnay Controller PZ-60DR-E
A
780
780
888
888
908
1144
1144
B
735
735
874
1016
954
1004
1231
C
273
273
315
315
386
399
399
D
768
768
875
875
895
1010
1010
E
782
782
921
1063
1001
1036
1263
E
Ø100
Ø150
Ø150
Ø200
Ø200
Ø250
Ø250
DIMENSIONS CEILING SUSPENSION FIXTURE PITCH
LGH-15-100RX5-E > LGH-150-200RX5-E >
LOSSNAY core
Maintenance cover
Control box
Air supply fan
cable opening
Air exhaust fanCeiling suspension fixture
By-pass damper plate
High efficiency filter(sold separately)attachment position
Air filters(EU-G3)
Power supply
(supply air)SA
(return air)RA
OA(outside air intake)
(exhaust air outlet)EA
399798Core, air filter, High-
Efficiency filter, fan,Maintenance space
(4-15x30 oval)
79
70
0
44
27
02
70
27
1010
1144
A
15
0~
25
0
Mor
e th
an 6
00
11
0
Inspection opening
258
242
258
242
B C
LG
H R
X5-E
Co
mm
erci
al S
erie
sLo
ssnay
Ran
ge
Dimensions
Page 263
� Control up to 15 Lossnay units
� New dot matrix display
� Weekly timer (ability to pre-set air volume requirements at different intervals)
� Night purge function
� Dimensions (WxDxH) mm: 130x19x120
Notes: Please use the Lossnay Technical Databook for specific, individual model schematics.
NOMINALDIAMETER
LGH-RX5-E
LOSSNAYMODEL REFERENCE
ELECTRICAL POWER SUPPLY
STARTING CURRENT (A)
RUNNING CURRENT (A) Extra Low
Low
High
Extra High
INPUT POWER (W) Extra Low
Low
High
Extra High
AIRFLOW (m3/h) Extra Low
Low
High / Extra High
AIRFLOW (l/s) Extra Low
Low
High / Extra High
EXTERNAL STATIC Extra Low
PRESSURE (Pa) Low
High
Extra High
NOISE (dBA) Lossnay Extra Low
Low
High
Extra High
Bypass Extra Low
Low
High
Extra High
TEMPERATURE Extra Low
EXCHANGE Low
EFFICIENCY (%) High
Extra High
ENTHALPY Heating Extra Low
EXCHANGE Low
EFFICIENCY (%) High / Extra High
Cooling Extra Low
Low
High / Extra High
WEIGHT (kg)
DIMENSIONS (mm) Width
Depth
Height
DUCT SIZE (mm)
STANDARD FILTER*1
FUSE RATING (BS88) – HRC (A)
MAINS CABLE NO. CORES
COMMERCIALLGH-25RX5-E
220-240V, 50Hz
0.9
0.18
0.27
0.48
0.55
42
62
114
129
105
155
250
29
43
69
9
25
60
85
19
21.5
26
27
19
22
26.5
27.5
83.5
81.5
79
79
77.5
74
69.5
76
72.5
68
20
735
780
273
150
EU-G3
6
3
COMMERCIALLGH-35RX5-E
220-240V, 50Hz
2.4
0.30
0.51
0.74
0.92
69
116
169
212
115
210
350
32
58
97
9
30
80
160
18
23
29.5
32
18
24
30.5
32.5
88
85
80
80
81.5
76.5
71.5
81
75.5
71
29
874
888
315
150
EU-G3
6
3
COMMERCIALLGH-50RX5-E
220-240V, 50Hz
3.0
0.40
0.85
1.00
1.25
95
190
228
286
180
390
500
50
108
139
10
60
90
155
19
28
32
34
19
29
32.5
35
86
81
78
78
78
71
69
77
68
66.5
32
1016
888
315
200
EU-G3
6
3
COMMERCIALLGH-65RX5-E
220-240V, 50Hz
4.4
0.60
1.20
1.50
1.80
140
265
322
380
265
520
650
74
144
181
8
50
80
120
22
31.5
33
34.5
22.5
30.5
33.5
35
86
80
77
77
78
70.5
68.5
77
68.5
66
40
954
908
386
200
EU-G3
6
3
COMMERCIALLGH-80RX5-E
220-240V, 50Hz
3.8
0.65
1.45
1.60
1.75
145
340
370
415
355
700
800
99
194
222
20
95
120
150
22
31
33
34.5
22
32
34
35.5
87.5
80.5
79
79
79.5
72.5
71
79.5
71.5
70
53
1004
1144
399
250
EU-G3
6
3
COMMERCIALLGH-100RX5-E
220-240V, 50Hz
4.6
0.90
1.70
2.10
2.40
200
380
475
535
415
755
1000
115
210
278
18
60
110
170
22
32.5
35
37
22
33
36
38
87
83
80
80
80
74
72.5
79
73
71
59
1231
1144
399
250
EU-G3
6
3
COMMERCIALLGH-150RX5-E
220-240V, 50Hz
7.3
-
2.90
3.20
3.50
-
680
740
830
-
1300
1500
-
361
417
-
100
135
175
-
35
37.5
39
-
37
39
40.5
-
81
80
80
-
72.5
72
-
71.5
70.5
105
1004
1144
798
(SA,RA)250 (OA,EA)270x700
EU-G3
10
3
COMMERCIALLGH-15RX5-E
220-240V, 50Hz
0.8
0.15
0.25
0.38
0.46
35
59
90
110
70
110
150
19
31
42
14
40
70
105
18
23.5
27
28
19
24
28
29
85.5
84
82
82
81
77.5
75
81
76.5
73
20
735
780
273
100
EU-G3
6
3
Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High and High mode available via dip switch setting. Extra Low mode not available on sizes 150 and 200. Noise measured at 1.5m under the centre of panel.*1: EU-F7 filter available as optional parts.
Commercial Series
This commercially orientated system can be utilised virtually anywhere.
� Effective fresh air ventilation
� High heat recovery
� Free cooling function
� Good sound attenuation
� New “Hyper Eco Core”. At only 25µm the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency
� The Lossnay-5-FSC Interface can also be used with LGH-RX5-E units.However, automatic fan speed control is with 3 speeds
Page 262
Technical Information
COMMERCIALLGH-200RX5-E
220-240V, 50Hz
11.9
-
3.40
4.20
4.80
-
785
980
1100
-
1580
2000
-
439
556
-
65
105
165
-
34
38
40
-
35
39
41
-
83
80
80
-
73.5
72.5
-
72
71
118
1231
1144
798
(SA,RA)250 (OA,EA)270x700
EU-G3
16
3
MODEL REFERENCE
LGH-15RX5-E
LGH-25RX5-E
LGH-35RX5-E
LGH-50RX5-E
LGH-65RX5-E
LGH-80RX5-E
LGH-100RX5-E
Lo
ssnay
Ran
geA
cces
sori
es /
Optional
Extr
as
Accessories / Optional ExtrasM Series
High Efficiency Filter PZ-25RFM - for LGH-15RX5-E / LGH-25RX5-E
PZ-35RFM - for LGH-35RX5-E
PZ-50RFM - for LGH-50RX5-E
PZ-65RFM - for LGH-65RX5-E
PZ-80RFM - for LGH-80RX5-E / LGH-150RX5-E (2 sets)
PZ-100RFM - for LGH-100RX5-E / LGH-200RX5-E (2 sets)
Page 264
The High Efficiency Filter
(with 65% colorimetricity EU-F7) can be incorporated inside the Lossnay LGH-RX5-E unit easily
Controls A Comprehensive Rangeof Control Options
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
The Importanceof Control
Page 266
The need for control is paramount in order to optimise the performanceof any air conditioning system and minimise its running costs and theemissions generated. Mitsubishi Electric offer a wide range of controloptions designed to do just this.
Operating an air conditioning system without the right controlcan prove costly. It’s therefore important to ensure that everysystem is correctly specified to the degree of control itrequires. Mitsubishi Electric have a wide range of controlsavailable ‘off-the-shelf’ and where needed, individual controlsystems can be specifically designed to suit.
Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors:different room sizes, usage and staff levels, changes in the climate, electronic equipment and lighting etc.
The ability to monitor the energy consumption and operationof systems is also vital. It is often said that you cannot managewhat you are not measuring. Our control systems will enablesimple measuring and monitoring of energy consumption andrunning costs to ensure operation is maintained.
So whatever the application, optimum control of air conditioningsystems is essential and will result in a constant, comfortableenvironment, which in turn is both energy and cost efficient.
A Degree of Difference
When an air conditioning system is not properly controlled, itwill not run as efficiently as it should. For every degree that thesystem deviates from the required temperature, energy costscan rise by up to 5%. Specify one of the many control optionsfrom Mitsubishi Electric to ensure air conditioning works asintended, whilst giving the optimum amount of control.
The Simpler the Better
With the array of comprehensive control systems availablefrom Mitsubishi Electric, it becomes simple to design and installair conditioning systems. From a simple hand held controller toan AG150 system - you are in control.
ControlledPerformance
Page 267
In accordance with the requirements ofPart L2 in the Building Regulations, our controlsystems provide the optimum control available,
combined with the most efficientuse of energy.
Application Low Cost and Features High
Option 1 Option 2 Option 3 Option 4 Option 5
Notes
On/Off remote controllerbutton lock except TCB1
AG150 andPAC-YG10HA
AT50IO InterfaceTCB1PAC-SA89TARemote On/Offor fire alarm
Relays or power supplymay be required
AG150 andPAC-YG10HA
AT50IO InterfacePAC-SA88HAMonitor run and faults
Controller will be centrallycontrolled when windowopened
---TCB1PAC-SA89TAWindowinterlocking
Available in Heat, Cooland Auto modes
AG150 andTG2000
AG150AT50PAR-F27MEAPAR-30MAASetpoint limit
Setpoint, On/Off canbe resetM2MAG150 and
TG2000AG150AT50PAR-30MAAWeekly timer
TCB1 requires thermostat,timeswitch, 12v power supplyM2MAG150 and
TG2000AG150AT50TCB1Night set back
Different options for eachchoice. Meters requiredMaxi M2MMini M2M
TG2000, AG150 andPAC-YG60MCA
AG150 andPAC-YG60MCA
AG150 and PAC-CN32WHMC-UK
Energymonitoring
Energy meters required--Maxi M2MMini M2MAG150 andPAC-YG60MCA
Load shedding
CSV data availableon a spreadsheet--Maxi M2MMini M2MAG150 and
TG2000Trend logging
PAC-SA89TA requires athird party timer---AG150PAC-SA89TANight mode
PT100 sensor required--Maxi M2MMini M2MAG150 andPAC-YG63MCA
Ambient tracking
Volt free contact forkey card normally open---
MELCOTELTM
and PAC-SA89TA
AG150, AG150-Interlockand PAC-SA89TA
Key card interlockfor hotel
Volt free contact for keycard normally closed----MELCOTELTM
and PAC-SA89TAWindow sensorinterlock for hotel
For instance, 19ºC Heatand 23ºC Cool. Fan only in between
--Maxi M2MMini M2MIO Interface2 setpoints (1 forcool and 1 for heat)
Backup, rotate, join in andhigh temperature function---PANEL_RS_SMSPAR-30MAA Duty / Standby
SIM card not supplied----Micro M2MA/C faults via SMS
-----AG150Optimised start
----Maxi M2MMini M2MMini BEMS
Which Controls Product for Which Function?
NOTE: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptorDISCLAIMER: These options are for guidance only
Application Small Medium Large Notes
A hotel usually requires interfacing with a keycard system and window contact. The MelcotelTM
has been designed to do just this for up to 250City Multi indoor units. The MelcotelTM can alsowork without a key card system
In an office application there is usually someonemanaging the air conditioning, so the interfaceneeds to be simple to use. The user friendlyAG150 touch screen is one option, as well as the TG2000 PC graphical user interface
Retail shops are usually managed by head officesor facility management companies, so it is key tohave remote monitoring of the air conditioning,but also any building services which can also beconnected to the M2M interfaces
In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications
In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications
Hotel
Office
Retail
Leisure
Education
AG150
PAR-30MAA PAR-F27MEA
IO Interface
PAR-30MAAPAR-F27MEAMini M2M
PAR-30MAA PAR-F27MEAMini M2M
MELCOTELTM
AG150
Mini M2M
AG150Maxi M2M
AG150Maxi M2M
MELCOTELTM
TG2000
Maxi M2M
AG150TG2000
AG150TG2000
It is really important to match the right control with the right application. From a hotel to a retailapplication, the solution will be different and the right control must be applied.
Which Controls Product for Which Application?
Page 268 Page 269
-
Page 270
The need for control is paramount in order to optimise the performance of any airconditioning system and minimise its running costs. Mitsubishi Electric offer a wide rangeof control options designed to do just this.
With the array of comprehensive controlsystems available from Mitsubishi Electric, it becomes simple to design and install airconditioning systems. From a simple handheld controller to an AG150 system -you are in control.
A Wide Range ofControl Options
Remote Controllers
AT50 Controller, Centralised Controller
Interfaces
IO Interface
AG150 Controller, Centralised Controller
AT50/AG150 Controller, Touch Screen Examples
AG150 Expansion Controller (PAC-YG50ECA)
GB50ADA Controller, Centralised Controller
AG150/GB50 Controller, Web Screenshots
PAR-21PC Desktop Remote Controller
AG150/GB50 Third Party Equipment Interfaces
AG150/GB50 MelcotelTM Hotel Interface, with key card system
AG150/GB50 MelcotelTM Hotel Interface, without key card system
AG150/GB50 MelcotelTM Hotel Interface, with M2M
TG2000 Software, PC Based Software Package
TG2000 Software with Energy Monitoring
Energy Monitoring
TG2000 Software with Third Party Equipment
TG2000 WAN Software (Wide Area Network)
TG2000, Screenshots
BEMS BACnet® Interface (BAC-IP/50)
BEMS BACnet® Interface (BAC-HD150)
BEMS BACnet® Mr Slim Interface (BAC-A/50)
BEMS LonWorks® Interface (LMAP)
BEMS Modbus Interface (MOD-IP/50)
BEMS Modbus Mr Slim Interface (A32M)
BEMS Modbus Splits Interface (A1M)
BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)
BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)
BEMS Trend Interface (Trend IQ3 Excite)
M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)
M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)
M2M - Machine 2 Machine Splits Interface (Micro M2M-SMS-A/08)
M2M - Machine 2 Machine Web Screenshots
Run Standby Panel (PANEL_RS_SMS)
Split-System A2M Interfaces
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
Page 271
Contents
AT50 ControllerThe new AT50 centralised controller is a low cost version of the very popular AG150 touch screen controller. The AT50 offers the main AG150 functionality, with a very simple and easy to use 5 inch touch screen.
AT50 PAC-SC51KUA
Co
ntro
lsR
ange
Rem
ote
Contr
olle
rs /
AT
50 C
ontr
olle
r
Technical Information
Page 273
AT50 Controller
MAX No. OF INDOOR UNITS
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
TIMER OPERATION
AIR FLOW DIRECTION
FAN SPEED SETTING
PERMIT/PROHIBIT FUNCTION
INDOOR RETURN AIR TEMPERATURE
ERROR INDICATION
TEST RUN FUNCTION
VENTILATION INTERLOCK
FIRE ALARM
NIGHT SET BACK
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
TOUCH SCREEN
FUNCTION
5” QVGA touch screen
Up to 50 indoor units can be connected
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC
Air Flow angles:100º-80º-60º-40º and auto swing
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
Displays the measured intake temperature from each group
Displays a 4 digit code and the affected unit address. An error log is held
Allows each unit within the group to operate in test mode
Allows the group to be interlocked with a heat recovery Lossnay unit
Units will be switched off and the remote controller will be locked under fire alarm condition
Power supply 240VAC 0.5A (PAC-SC51KUA required)
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF
180x30x120
DESCRIPTION
Remote Controllers
Remote Controllers
PAR-FL32MAPAR-30MAA PAR-F27MEAPAC-YT51CRB PAC-SE51CRA BS-51COV-B PS-51COV-B PB-51COV-B
ON/OFF
MODE SELECTION
TEMPERATURE
SETTING
FAN SPEED SETTING
SETPOINT LIMIT
AIRFLOW DIRECTION
INDEPENDENT VANE
CONTROL
TIMER OPERATION
PERMIT / PROHIBIT
FUNCTION
INDOOR RETURN AIR TEMPERATURE
ERROR INDICATION
TEST RUN FUNCTION
VENTILATION INTERLOCK
OPTIONAL COVER
CONTACT NUMBERUNDER FAULT CONDITIONS
EASY MAINTENANCEWITH MR SLIM
BACKLIGHT DISPLAY
BUTTON LOCK
ENERGY SAVING
SILENT MODE
NIGHT SET BACK
RUN / STANDBY WITH
MR SLIM
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
FUNCTION
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat.Operation mode will vary depending on theindoor unit. Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C
4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi
Limit the setpoint range
Air Flow angles:100º-80º-60º-40ºand auto swing
Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E
ON/OFF time can be set.
Run/Stop, Temperature Setting, Mode Selectionand Filter Reset functions can be prohibited via a higher level system controller
Measures the intake temperature of the master unit within the group
Displays a 4 digit code and the affected unit address
Allows each unit within the group to operate in test mode
Allows the group to be interlocked with a heat recovery Lossnay unit
Brushed Stainless Steel
Polished Stainless Steel
Polished Brass
Displays under fault condition, the fault code of the unit with its address and the contact number to call
Able to monitor info about the compressor(running current, running time, On/Off time).Also able to monitor sensors: h-exh, OU outlet,OU temp, IU inlet, IU h-exh and filter usage
Backlight display. Displays current time
Able to lock all controller buttons, or all controller buttons except On/Off
Reset the unit setpoint after a period of time
Activate with scheduling the silent modeon the outdoor unit
Maintain a min and max temperature
Able to switch over two systems every week. If one fails, the other system starts. If thetemperature is too high, the two systems start.
Compatible with:
DESCRIPTION PAC-YT51CRB PAC-SE51CRA PAR-30MAA PAR-F27MEA PAR-FL32MA
Weekly Weekly Daily Daily Daily Daily
Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type, whilstbeing able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.
Mr Slim or M Series (via MAC-397IF)
City Multi, Mr Slim(via PAC-SF81MA)
or M Series(via MAC-399IF)
City Multi, Mr Slim(via PAC-SF81MA)
or M Series(via MAC-399IF)
City Multi, Mr Slim or M Series (via MAC-397IF)
City Multi (via PAR-FA32MA) or Mr Slim (via PAR-FA32MA)
120x41x70 120x41x70 120x19x120 130x19x120 157x18x57
Operation Display Operation Display Operation Display Operation Display Operation Display
� � � � � � � � � �
� � � � � � � � � �
� �
� �
� � � �
� � � �
� �
� �
� �
� �
�
�
�
� �
� �
� � � � � � � �
� � � � �
� �
� � � �
�
�
�
�
� �
�
� �
� �
�
�
�
�
�
�
� � � � � � � �
Technical Information
Page 272
� �
During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keepthe temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C
IO InterfaceThe new IO interface has been developed to allow third party systems, for instance BEMS companies, to easily controland monitor our air conditioning systems using simple volt free contacts and 0 to 10VDC signals. By working veryclosely with our main retail clients we have added some beneficial energy saving features, whilst still offering anacceptable level of control for retail applications. To avoid wasting energy the IO interface can also be used tointerlock third party heating systems to our air conditioning.
IO Interface
IO Interface
UNIT 1 or 16*1
ON/OFF Run and Stop operation for a single group Volt Free ContactInput
ENERGY SAVE Energy Save can be activated. 2 options are available Volt Free ContactInput
TEMPERATURE SETTING Sets the groups temperature control 0 to 10VDCInput
MODE Switches between Cool/Dry/Auto/Fan/Heat. Operation modewill vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
0 to 10VDCInput
LOCK Run/Stop, Temperature Setting, Mode Selection and FilterReset functions can be prohibited
Volt Free ContactInput
FAN SPEED 4 speed - Lo-Mi1-Mi2-Hi2 speed - Lo-Hi
0 to 10VDCInput
RUN STATUS - Volt Free ContactOutput
FAULT - Volt Free ContactOutput
HEAT / COOL Activates when unit is in heating or cooling mode Volt Free ContactOutput
THERMO Activates when room temperature is 2ºC away from setpoint Volt Free ContactOutput
COMPATIBILITY Mr Slim and M Series --
DIMENSIONS - mm (WxDxH) 85x32x138 --
FUNCTION DESCRIPTION IO INTERFACE
Co
ntro
lsR
ange
Technical Information
INPUTS / OUTPUTS
Inte
rfac
es /
IO
Inte
rfac
e
Page 275
Energy Saving Features
MODE 1 MODE 2
*1 The IO Interface can control up to 16 indoor units when the fault output is not used. When the fault output is used only one indoor unit can be controlled. Page 274
InterfacesA range of newly created interfaces are now available for use when connecting to third party controllers.
TCB1
TCB1
Interfaces
ON/OFFBUT CENTRALLYCONTROLLED
ON/OFF BUTNOT CENTRALLY CONTROLLED
TEMPERATURE SETTINGS
RUN INDICATION
ERROR INDICATION
COMPATIBILITY
DIMENSIONS - mm(WxDxH)
FUNCTION
ON/OFF control. Remote controller ON/OFF button deactivated
ON/OFF control. Remote controller ON/OFF button activated
Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C
Interface compatible with:
DESCRIPTION TCB1
Technical Information
Control Monitor
PAC-SA88HA
Control Monitor
PAC-SA89TA
Control Monitor
80x45x80
Mr Slim
City Multi
Mr Slim
City Multi
Mr Slim
City Multi
�
PAC-SA88HAPAC-SA89TA
(12VDC)
�
(VFC)
(12VDC)
(12VDC)
NOTE: VFC: Volt free contact.PAC-SA89TA is also known as a 3 wire adaptor.PAC-SA88HA is also known as a 5 wire adaptor.
PAC-SA88HAPAC-SA89TA
�
�
The energy saving mode 1 sets the indoor unit to Auto modewhenever a momentary signal is applied to the ‘Energy Save’ input or whenever the on/off state is changed from OFF to ON.The unit will operate in AUTO for 0.5, 1 or 2hours and then revert back to fan only.
The timer can be reset using the Energy Save input.
The energy saving mode 2 sets two setpoints for the indoorunit, one for heating and one for cooling. In between theindoor unit will be running in fan only mode.
OFF OFFAUTO FAN
OFF OFFAUTO AUTOFAN FAN
09.00 11.00 13.00 15.00 17.00 19.00
09.00 11.00 13.00 15.00 17.00 19.00Active via push button
2524232221201918
COOLING MODE
FAN ONLY MODE
HEATING MODE
Max No. of indoor units -
AT50/AG150 Controller Touch Screen Examples
Page 277
Co
ntro
lsR
ange
AT50 Home Screen 1 AG150 Home Screen 1
AT50 Home Screen 2 AG150 Home Screen 2
AG150 Home Screen 3AT50 Home Screen 3
AT50 Indoor Unit Settings AG150 Indoor Unit Settings
AT50 Scheduling AG150 Scheduling
DEMONSTRATION
Touch Screen Centralised Controller with WebServer Capabilities
AG150 Controller
The AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control of up to 50indoor units. The AG150 can calculate the energy used for each system. The refrigerant status check function can beactivated regularly (in conjuction with the new YJM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and receive Email under fault conditions.
AG150 - Basic
AG150 - Energy
Web monitoring, Email, Annual scheduling AG150 - VRC Virtual remote controllers
Energy monitoring, energy saving, load shedding AG150 - Interlock Interlocking function
AG150 Software Options - Pin Code Activation
Technical Information
ETHERNET
AG150
M-NET
PAC-SC51KUA
Visit wwwL1.mitsubishielectric.co.jp/wink_doc/wink_files/acr/menu/ag150
Page 276
AG150 Controller
OPERATION PLATFORM
MAX No. OF INDOOR UNITS
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
TIMER OPERATION
AIR FLOW DIRECTION
FAN SPEED SETTING
PERMIT/PROHIBIT FUNCTION
INDOOR RETURN AIR TEMPERATURE
ERROR INDICATION
TEST RUN FUNCTION
VENTILATION INTERLOCK
OPTIMISED START
AUTOMATIC SETPOINT ADJUSTMENT
AUTO LOCK
NIGHT SET BACK
AutoCAD DRAWING
WEB LOGIN
WEB SETPOINT LIMIT
WEB AUTO CHANGEOVER
WEB INITIAL SETTING
WEB REFRIGERANT STATUS CHECK
WEB-INTERLOCK
WEB-LOAD SHEDDING
EXTERNAL INPUT/OUTPUT
FIRE ALARM
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
TOUCH SCREEN
FUNCTION
Wide high resolution 9” touch screen
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
Up to 50 indoor units can be connected or 150 using an expansion controller (PAC-YG50ECA)
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
Annual or weekly. Night set back available allowing the setpoint to be set to 12ºC
Air Flow angles:100º-80º-60º-40º and auto swing
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
Displays the measured intake temperature from each group
Displays a 4 digit code and the affected unit address including the description of the error. An error log is held
Allows each unit within the group to operate in test mode
Allows the group to be interlocked with a heat recovery Lossnay unit
The equipment is started only as early as required to bring the building to a setpoint at the time it will be occupied.Running in an optimal state helps reduce energy usage.
The AG150 will change the setpoint depending of the outdoor temperature. PAC-YG63MCA and a PT100 sensor arerequired (PT100 sensor not supplied by MEUK). This function is only available in COOL mode
The AG150 screen can be password protected. When the screen goes to standby and when the AG150 restarts,a username and password will be required
During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keepthe temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C
Administrator able to allow specific function access to guest
Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
Commission the AG150 from the web pages
Activate refrigerant volume checking function on Modular City Multi systems
The AG150 can interlock indoor unit input and output together. For instance, this function could be used for Hotelapplications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could alsobe set in conjunction with PIR sensor in meeting rooms
Activate energy saving mode when energy consumption is too high
Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status
Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA
Power supply 240VAC 0.5A (PAC-SC51KUA required)
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF
300x62x175
DESCRIPTION
A floor plan of the building in auto-cad format can be uploaded. For the facilities department it makes viewing and adjusting settings easier
Viewed using Microsoft® Internet Explorer
AG1
50 C
ontr
olle
r /
AT
50/A
G1
50 C
ont
rolle
r To
uch
Scre
en E
xam
ples
Centralised Controller with WebServer Capabilities
GB50ADA Controller
G50 - EC
G50 - ES
G50 - PC
G50 - VRC
Energy Charge
Energy Saving Capability
Peak Cut Control
Virtual Remote Controllers
GB50 Software Options - Pin Code Activation
ETHERNET
The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.
GB50ADA Controller
OPERATION PLATFORM
MAX No. OF INDOOR UNITS
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
FAN SPEED SETTING
AIR FLOW DIRECTION
TIMER OPERATION
PERMIT/PROHIBIT FUNCTION
INDOOR RETURN AIR TEMPERATURE
ERROR INDICATION
TEST RUN FUNCTION
VENTILATION INTERLOCK
WEB LOGIN
WEB SETPOINT LIMIT
WEB AUTO CHANGEOVER
WEB INITIAL SETTING
WEB REFRIGERANT STATUS CHECK
WEB-INTERLOCK
WEB-LOAD SHEDDING
EXTERNAL INPUT/OUTPUT
FIRE ALARM
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
FUNCTION
CPU 1000 Mhz, 512MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
Up to 50 indoor units can be connected
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
Air Flow angles:100º-80º-60º-40º and auto swing
Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
Displays the measured intake temperature from each group
Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms
Allows each unit within the group to operate in test mode
Allows the group to be interlocked with a heat recovery Lossnay unit
Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status
Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA
Power supply 240VAC 3.2A
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF
250x97x266
DESCRIPTION
Technical Information
M-NET
Viewed using Microsoft® Internet Explorer
GB50ADA
Co
ntro
lsR
ange
PAC
-YG
50EC
A / G
B50
AD
A C
ont
rolle
r
Page 279
Technical Information
PAC-YG50ECA
AG150 / PAC-YG50ECA CONNECTION
POWER SUPPLY
DIMENSIONS - mm (WxDxH)
FUNCTION
Ethernet. Ethernet hub and network cables required and not supplied by MEUK
240VAC 3.2A
250x97x266
DESCRIPTION
PAC-YG50ECA
0 to 50
51 to 100
101 to 150
NUMBER OF INDOOR UNITS
1
1
1
0
2
3
NUMBER OF AG150 REQUIRED NUMBER OF PAC-YG50ECA REQUIRED
AG150 Expansion Controller
PAC-YG50ECA
The PAC-YG50ECA expansion controller allows the AG150 to monitor and control up to 150 indoors units.
ETHERNET
PAC-SC51KUA
PAC-YG50ECA
PAC-YG50ECA
PAC-YG50ECA
AG150
HUB
Page 278
Administrator able to allow specific function access to guest
Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
Commission the GB50 from the web pages
Activate refrigerant volume checking function on Modular City Multi systems
The GB50 can interlock indoor unit input and output together. For instance, this function could be used for Hotelapplications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms
Activate energy saving mode when energy consumption is too high
PAR-21PC Desktop Remote Controller
More and more customers are using the AG150/GB50 controllers directly from their computers, so MitsubishiElectric has launched a new, even simpler alternative which presents the customer with what looks like a standardremote controller interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimisedin the Desktop Toolbar, just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
ETHERNET
PAR-21PC Desktop Remote Controller
OPERATION PLATFORM
MAX No. OF INDOOR UNITS
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
FAN SPEED SETTING
AIR FLOW DIRECTION
CLOCK DISPLAY
INDOOR RETURN AIR TEMPERATURE
ERROR INDICATION
TIMER OPERATION
COMPATABILITY
FUNCTION
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2
Up to 16 indoor units within a group
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
Air Flow angles:100º-80º-60º-40º and auto swing
Displays the time on the desktop controller
Displays the measured intake temperature from each group
Displays a 4 digit code and the affected unit address.
Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated
AG150 and GB50
DESCRIPTION
Technical Information
M-NET
PAC-SC51KUA
*NOTE 1
Page 281
Co
ntro
lsR
ange
AG
150/G
B50 C
ontr
olle
r W
eb S
cree
nsh
ots
/PA
R-2
1PC
Des
ktop R
emao
teC
ontr
olle
r
AG150/GB50 Controller Web Screenshots
Login
Access to the web pages is secured using a customisedusername and password.
Monitor Air Conditioning - Overview
The first screen allows you to monitor all the units connected to theAG150/GB50. Each icon displays On/Off, Faults and timer On/Off.
Monitor Air Conditioning - Block view
Each area of the building can be displayed with informationabout On/Off, Setpoint , Mode and Temperature.
Remote Controller Settings
Click on any icons in the Monitor View page to access theremote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).
Daily, Weekly and Annual Scheduling (AS PIN code)
Scheduling may be set from the web pages. A night set back operation is available (Heat, 12ºC).Standard on the AG150/GB50.
Monitor Fault Codes
Faults with the unit address can be displayed under fault conditions. Email status can also be shown.
Multiple Users (VRC PIN code)
If the AG150/GB50 is connected to an office LAN, the staffwill then be able to access the web pages. With VRC eachmember of staff will have their own username and password.
Multiple Users (VRC PIN code)
Installation costs will be reduced as no wall remotecontrollers will need to be purchased and installed.
Icons available to suit model type installed
Page 280
MELCOTELTM
MAX No. OF INDOOR UNITS
TIME TO SWITCH ON
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
OCCUPIED ROOM SETTING
UNOCCUPIED ROOM SETTING
SEASONS
OPTIONAL WINDOW CONTACT
AUTOMATIC SETPOINT
ADJUSTMENT NIGHT TIME OFFSET
INDOOR UNIT CONNECTION
SOFTWARE
FIRE ALARM
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
FUNCTION DESCRIPTION
Key Card
WindowControl
Key Card
WindowControl
Key Card
WindowControl
ETHERNET
MelcotelTM
Technical Information
M-NET
PAC-SC51KUA
AG150/GB50 MelcotelTM
Hotel Interfacewith Key Card System
The MelcotelTM hotel interface allows a hotel (for example) to have more accurate control over its air conditioning. The MelcotelTM works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the MelcotelTM will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC). When the room is unoccupied, the MelcotelTM will monitor the temperaturein the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM alsooffers temperature adjustment facility based on the outside temperature and window open control, that allowsthe air conditioning to be switched off and controlled centrally when a window is opened. All of these functionsprovide a higher level of control and therefore more energy saving and a reduction in running costs.
AG150
Up to 250 indoor units
<30s
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
Configurable. ON, AUTO, 21ºC (Factory setting)
Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)
If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unitwhen the window is opened
The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)
During the night the MelcotelTM can offset the setpoint or just switch OFF the unit
The key card and the window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit
The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Statusallows the user to monitor all the different values, for instance, Setpoint, Mode, Key Card IN or OUT, Window Contact etc
Units will be switched off and the remote controller will be locked under fire alarm condition
240 VAC 2A
GB50 and AG150, but City Multi only
300x70x350
DEMONSTRATION Visit www.melcotel.co.uk for more details
USB
If the temperature is above 26ºC the MelcotelTM
restarts the unit to ON, COOL, 21ºC and stopsthe unit when the temperature has reached 24ºC (Factory setting)
If the temperature is below 16ºC the MelcotelTM restartsthe unit to ON, HEAT, 19ºC and stops the unit when thetemperature has reached 18ºC (Factory setting)
Page 283
Co
ntro
lsR
ange
AG
150/
GB
50 T
hird
Par
ty E
quip
men
t In
terf
aces
/M
elco
telT
M
Hote
l In
terf
ace
with K
ey C
ard S
yste
m
The new third party equipment interfaces allow the user to monitor and control third party equipment from theAG150/GB50 web pages.
AG150/GB50
Third Party Equipment Interfaces
*NOTE 1
FUNCTION
MAX No. OF INPUTS
MAX No. OF OUTPUTS
MAX No. OF EQUIPMENT
POWER SUPPLY
MONITOR
CONTROL
SIGNAL
DIMENSIONS - mm (WxDxH)
DESCRIPTION PAC-YG66DCA PAC-YG63MCA
Power supply required
Third Party Interfaces
From AG150/GB50 web pages or TG2000
From AG150/GB50 web pages or TG2000
Signal required to monitor and control equipment
2 x Digital
2 x Digital
2
-
-
-
-
-
-
24VDC
Run / Faults
On/Off
Volt free contact
200x45x120
2 x Analogue
24VDC
Temperature / Humidity
-
Temperature 4-20mA / 1-5V / 0-10V / Pt100Humidity 4-20mA / 1-5V / 0-10V
200x45x120
Technical Information
PAC-YG66DCA PAC-YG63MCA
General Equipment
Third party equipment can be monitored and controlledfrom the web pages.
Temperature / Humidity
Temperature and humidity can be monitored.
Trend Logging
Temperature and humidity can be recorded and displayed.
Temperature / Humidity Limit
Limit (high and low) can be set to trigger alarms via email.
ETHERNET
EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK
Page 282
MELCOTELTM
MAX No. OF INDOOR UNITS: UP TO 250
ON/OFF
MODE
ROOM TEMPERATURE
SET TEMPERATURE
SET BACK
KEY CARD
WINDOW SENSOR
EXTERNAL TEMPERATURE
FUNCTION
MelcotelTM
Technical Information
AG150/GB50 MelcotelTM
Hotel Interfacewith Machine 2 Machine
The MelcotelTM hotel interface can be connected to the Mini M2M Machine 2 Machine interface to allowremote monitoring of the air conditioning, but also the window contact and the key card system.
MEUK
M2M SERVER
GPRS
Mini M2M-A/16
MelcotelTM
Mini M2M-A/16
DEMONSTRATION Visit www.melcotel.co.uk for more details
Page 285
Co
ntro
lsR
ange
Mel
cote
lTM
Hote
l Int
erfa
ce w
itho
ut K
ey C
ard
Syst
em /
Mel
cote
lTM
Hote
l In
terf
ace
with M
2M
MELCOTELTM
MAX No. OF INDOOR UNITS
TIME TO SWITCH ON
ON/OFF
MODE SELECTION
TEMPERATURE SETTING
OCCUPIED ROOM SETTING
UNOCCUPIED ROOM SETTING
SEASONS
OPTIONAL WINDOW CONTACT
AUTOMATIC SETPOINT
AUTO SWITCH OFF
ADJUSTMENT NIGHT TIME OFFSET
INDOOR UNIT CONNECTION
SOFTWARE
FIRE ALARM
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
FUNCTION
Up to 250 indoor units
<30s
Run and Stop operation for a single group
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
Configurable. ON, AUTO, 21ºC (Factory setting)
Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)
If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unitwhen the window is opened
The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)
6 Off times can be preset to regularly switch OFF the indoor unit
During the night the MelcotelTM can offset the setpoint or just switch OFF the unit
The window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit
The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM
Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Window Contact etc
Units will be switched off and the remote controller will be locked under fire alarm condition
240 VAC 2A
GB50 and AG150, but City Multi only
300x70x350
DESCRIPTION
If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)
If the temperature is above 26ºC the MelcotelTM restartsthe unit to ON, COOL, 21ºC and stops the unit whenthe temperature has reached 24ºC (Factory setting)
WindowControl
WindowControl
Technical Information
AG150/GB50 MelcotelTM
Hotel Interfacewithout Key Card System
The MelcotelTM controller allows a hotel (for example) to have more accurate control over its air conditioning. When theunit has been switched ON by a user, the room is deemed as occupied and the MelcotelTM resets the air conditioning topredetermined settings (for instance AUTO, 21ºC). After a preset time, the MelcotelTM will switch OFF the unit automatically.When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low ortoo high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outsidetemperature and window open control, that allows the air conditioning to be switched off and controlled centrally when awindow is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.
DEMONSTRATION Visit www.melcotel.co.uk for more details
ETHERNET
MelcotelTM
M-NET
PAC-SC51KUA
AG150
USB
WindowControl
Page 284
TG2000 Software with Energy Monitoring
M-NET
ETHERNET
PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor upto a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioningsystem via the AG150/GB50 controller, allowing the operator all the required functionality to control andmonitor the complete air conditioning system from a central location. In addition to providing a centralisedcontrol facility, the TG2000 allows complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.
Technical Information
PAC-SC51KUA
*NOTE 1
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Energy Meters not supplied by MEUK
TG2000 Software with Energy Monitoring
OPERATING PLATFORM
MAX No. OF INDOOR UNITS
OPERATIONAL SECTIONS
ON/OFF
OPERATION MODE
SET TEMPERATURE
AIR SPEED
REMOTE CONTROLLER
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING
ROOM TEMPERATURE MONITORING
SCHEDULED ON/OFF
ENERGY CHARGING
WEB REFRIGERANT STATUS CHECK
ENERGY CHARGING
ENERGY SAVE CONTROL
LOAD SHEDDING
TREND LOGGING
GRAPHICAL SCREENS
FUNCTION
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
2000 Indoor units, 50 indoor units per AG150/GB50
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
Indicates the On/Off status of each group within the selected graphical screen or entire building
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
Displays the current fan speed setting for each group on the selected graphical screen
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
Displays the return air temperature of the master indoor unit within a group
On/Off schedules can be set for each group, each graphical screen or the entire building
Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA
Activate refrigerant volume checking function on Modular City Multi systems
Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional)via the PAC-YG60MCA
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
Activate energy saving mode when energy consumption is too high
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
DESCRIPTION
METER 1 METER 2 METER 3 METER 4
PAC-YG60MCA
Page 287
Co
ntro
lsR
ange
TG
2000 S
oft
war
e /
TG
2000 S
oft
war
e w
ith E
ner
gy M
onitori
ng
TG2000 Software
M-NET
ETHERNET
PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to amaximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via theAG150/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.
Technical Information
PAC-SC51KUA
*NOTE 1
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
TG2000 PC Based software that works in conjunction with AG150/GB50 Controller
OPERATING PLATFORM
MAX No. OF INDOOR UNITS
OPERATIONAL SECTIONS
ON/OFF
OPERATION MODE
SET TEMPERATURE
AIR SPEED
REMOTE CONTROLLER
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING
ROOM TEMPERATURE MONITORING
SCHEDULED ON/OFF
ENERGY SAVE CONTROL
TREND LOGGING
GRAPHICAL SCREENS
FUNCTION
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista or Windows 7
2000 Indoor units, 50 indoor units per AG150/GB50
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
Indicates the On/Off status of each group within the selected graphical screen or entire building
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
Displays the current fan speed setting for each group on the selected graphical screen
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
Displays the return air temperature of the master indoor unit within a group
On/Off schedules can be set for each group, each graphical screen or the entire building
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
DESCRIPTION
Page 286
Energy monitoring is key to comply with Part L2 regulations. Some time ago we introduced the PAC-YG60MCA MNETinterfaces, which can be connected anywhere on our MNET network and will monitor up to 4 pulse meters. These interfacesmake installation easier, more cost effective and are shown in option A below.
This year, all of our City Multi outdoor units now have a direct connection to pulse meters. This means that the pulse meter canbe connected to the outdoor unit directly, negating the need for interfaces, panels and a power supply and therefore reducing theinstallation cost significantly. This is shown in option B below.
Energy Monitoring
FUNCTION
OUTDOOR kW
INDOOR kW
PRODUCT REQUIRED DESCRIPTION
Pulse Meter Direct Connection to City Multi Outdoor Unit
Product Required
The energy consumption of the outdoor can be monitored using the AG150 Webpages
The energy consumption of the indoor unit can be estimated using theTG2000 software package. The software package will also allow the enduser to generate bills with multiple tariffs
AG150, AG150-BasicEnergy Meters
AG150, AG150-BasicAG150-Energy, TG2000Energy Meters
Technical Information
Page 288
Cable required to connect the pulse meter to the outdoor unit
Jumper to activate the outdoor pulse input
PAC-SA89TA
PAC-CN32WHMC-UK
M-NET
ETHERNET
PAC-SC51KUA
*NOTE 1
METER 1 METER 2 METER 3 METER 4
PAC-YG60MCA
M-NET
ETHERNET
PAC-SC51KUA
*NOTE 1
METER 1
PAC-YG60MCA
Option A:
Option B:
Page 289
Co
ntro
lsR
ange
Ener
gy M
oni
tori
ng /
TG
2000
Soft
war
e w
ith
Thi
rd P
arty
Equ
ipm
ent
M-NET
ETHERNET
PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to amaximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor thecomplete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.
Technical Information
PAC-SC51KUA
*NOTE 1
PAC-YG66DCA PAC-YG63MCA
EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
TG2000 Software with Third Party Equipment
OPERATING PLATFORM
MAX No. OF INDOOR UNITS
OPERATIONAL SECTIONS
ON/OFF
OPERATION MODE
SET TEMPERATURE
AIR SPEED
REMOTE CONTROLLER
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING
ROOM TEMPERATURE MONITORING
SCHEDULED ON/OFF
ENERGY SAVE CONTROL
TREND LOGGING
GRAPHICAL SCREENS
THIRD PARTY EQUIPMENT MONITOR
THIRD PARTY EQUIPMENT CONTROL
FUNCTION
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
2000 Indoor units, 50 indoor units per AG150/GB50
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
Indicates the On/Off status of each group within the selected graphical screen or entire building
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
Displays the current fan speed setting for each group on the selected graphical screen
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
Displays the return air temperature of the master indoor unit within a group
On/Off schedules can be set for each group, each graphical screen or the entire building
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by groupor by indoor unit, watt-hour meter and then email to customer
The complete system configurations can be allocated between multiple screens. Each screen can displaya bitmap image representing the area of the building or floor where the units or groups are physically located
Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA
Control general equipment On/Off via the PAC-YG66DCA
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
DESCRIPTION
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Temperature and Humidity Sensors not supplied by MEUK
TG2000 Software with Third Party Equipment
PC Based Software Package used to monitor and control multiple sites
The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitorup to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed)air conditioning asset base can be controlled and monitored from a centralised location.
SITE 1(i.e. MANCHESTER)*NOTE 1
SITE 999(i.e. BIRMINGHAM)*NOTE 1
TG2000WAN (Wide Area Network) Software
OPERATING PLATFORM
MAX No. OF SITES
MAX No. OF INDOOR UNITS PER SITE
OPERATIONAL SECTIONS
ON/OFF
OPERATION MODE
SET TEMPERATURE
AIR SPEED
REMOTE CONTROLLER
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING
ROOM TEMPERATURE MONITORING
SCHEDULED ON/OFF
GRAPHICAL SCREENS
THIRD PARTY EQUIPMENT MONITORING
THIRD PARTY EQUIPMENT CONTROL
FUNCTION
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
1000
2000 Indoor units, 50 indoor units per AG150/GB50 (per site)
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
Indicates the On/Off status of each group within the selected graphical screen or entire building
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
Displays the current fan speed setting for each group on the selected graphical screen
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
Displays the return air temperature of the master indoor unit within a group
On/Off schedules can be set for each group, each graphical screen or the entire building
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA
Control general equipment On/Off via the PAC-YG66DCA
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
DESCRIPTION
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging.NOTE 3: Temperature and Humidity Sensors not supplied by MEUK
Technical Information
PAC-YG66DCA PAC-YG63MCA
EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
PAC-YG66DCA PAC-YG63MCA
EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
WAN
TG2000 WAN (Wide Area Network) Software
Page 291
Co
ntro
lsR
ange
Page 290
TG2000 ScreenshotsDisplay Whole
The 2000 indoor units status may be shown on one screen.
Display Block
Block may be set for each area. Settings may bechanged by one click of the mouse for each area.
Display Floor
AutoCAD drawing may be imported to TG2000 to display floor screens.
Remote Controller Settings
Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).
Daily, Weekly and Annual Scheduling
Scheduling may be set from the TG2000. A nightset back operation is available (HEAT, 12ºC).
Monitor Fault Codes
Faults with the unit address can be displayed underfault conditions.
Energy Monitoring (AG150 Energy PIN code)
TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.
Energy Saving (AG150 Energy PIN code)
TG2000 offers different energy saving options including load shedding.
Icons available to suit model type installed
TG
2000 W
AN
Soft
war
e/
TG
2000 S
cree
nsh
ots
BACnet® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
4 Character code - Indicates all unit alarms
-
-
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Input
Analogue Input
Digital Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
ProconTM BAC-IP/50
BEMS BACnet®
Interface
To further enhance our complete open system network offering, we offer a BACnet® interface solution.Utilising the ASHRAE BACnet® standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.
BACnet® INTERFACEFUNCTION BAC-IP/50 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
50
Yes (AG150 or GB50)
24VAC 0.5A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Ethernet via HUB
144x34x104
Andover Controls
York BMS
Siemens
Priva Building Intelligence
Delta Controls
Technical Information
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
BAC-IP/50
ETHERNETPAC-SC51KUA
M-NET
*NOTE 1
Page 293
Co
ntro
lsR
ange
Page 292
BAC-HD150
BEMS BACnet®
Interface
To further enhance our complete open system network offering, we offer a BACnet® interface solution. Utilising the ASHRAE BACnet® standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.
Technical Information
BAC-HD150
BACnet® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
4 Character code - Indicates all unit alarms
-
-
BACnet® INTERFACEFUNCTION BAC-HD150 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
50
No
240VAC 3.2A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Ethernet
250x97x266
Andover Controls
York BMS
Siemens
Priva Building Intelligence
Delta Controls
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Input
Analogue Input
Digital Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
BEM
S B
AC
net
®In
terf
aces
TCP / IP TCP / IP
ProconTM BAC-A/50
BEMS BACnet® Mr Slim Interface
A new BACnet® Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can control up to50 individual systems.
PAC-SK82SI
BAC-A/50
BACnet® MR SLIM INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
4 Character code - Indicates all unit alarms
-
-
BACnet® MR SLIM INTERFACEFUNCTION BAC-A/50 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
Andover Controls
York BMS
Siemens
Priva Building Intelligence
Delta Controls
Technical Information
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Input
Digital Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
Digital Output
Analogue Output
Page 295
Co
ntro
lsR
ange
Page 294
50
No
240VAC 0.5A
Mr Slim via PAC-SK82SI
Ethernet
270x75x210
BEMS LonWorks® Interface
The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party building control systems using the globally recognised and accepted open network protocol Echelon LonWorks®.LonWorks® was introduced into the building services industry a number of years ago with the aim of establishing itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks®
protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches.
To ensure that our products can connect directly and easily with other LonWorks® products, the L-MAP02was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks®
SNVT (Standard Network Variable Type) format.
LMAP
LMAP
M-NET
Technical Information
LMAP LonWorks® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
4 Character code - Indicates all unit alarms
-
-
LMAP LonWorks® INTERFACEFUNCTION LMAP COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
50
No
240VAC 0.5A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
LonWorks FTT-10
340x60x360
Honeywell
Johnson Controls
Realtime Control Systems (LTX51/LTX21 via VCI)
Smart Controls
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Input
Digital Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
Digital Output
Analogue Output
BEM
S B
AC
net
®M
r Sl
im Inte
rfac
e/
BEM
S Lo
nW
ork
s®In
terf
ace
TCP / IP
FTT-10
MODBUS INTERFACE - OPERATIONAL INFORMATION
FUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
4 Character code - Indicates all unit alarms
-
-
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Input
Analogue Input
Digital Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
Analogue Output
Digital Output
Analogue Output
BEMS Modbus Interface
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric tosupport their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
ProconTM MOD-IP/50
ETHERNETPAC-SC51KUA
M-NET
*NOTE 1
Modbus
MODBUS INTERFACEFUNCTION MOD-IP/50 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
50
Yes (AG150 or GB50)
240VAC 0.5A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Serial RS232, RS485 or TCP / IP
144x34x104
Trend via Synapsys SXNC200
Cylon
Satchwell
Crestron (Home automation)
Invensys
Interactive Homes
North BT
Andover
Siemens
Technical Information
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 297
Co
ntro
lsR
ange
Page 296
BEMS Modbus Mr Slim Interface
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
ProconTM A32M
PAC-SK82SI
A32M
Modbus
MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION
FUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Fault Code
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
4 Character code - Indicates all unit alarms
-
MODBUS MR SLIM INTERFACEFUNCTION A32M COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
32
No
240VAC 0.5A
Mr Slim via PAC-SK82SI
Serial RS232 or 485
270x75x210
Trend via Synapsys SXNC200
Cylon
Satchwell
Crestron (Home automation)
Invensys
Interactive Homes
North BT
Andover
Siemens
Technical Information
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
NOTE: Not available on SEZ / SLZ BEM
S M
odbus
Inte
rfac
e/
BEM
S M
odbus
Mr
Slim
Inte
rfac
e
RS232 / 485 or TCP / IP
RS232 / 485
BEMS Modbus Splits Interface
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
ProconTM A1M
A1M
Modbus
MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION
FUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Fault Code
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
4 Character code - Indicates all unit alarms
-
MODBUS SPLITS INTERFACEFUNCTION A1M COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
1
No
M SeriesMr Slim
Serial RS485
72x27x50
Trend via Synapsys SXNC200
Cylon
Satchwell
Crestron (Home automation)
Invensys
Interactive Homes
North BT
Andover
Siemens
Technical Information
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Page 299
Co
ntro
lsR
ange
Page 298
BEMS KNX-EIB Interfaces
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric tosupport their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.
KNX-EIB-IP-15
KNX-EIB-IP-100
ProconTM KNX-EIB-IP-15/100
ETHERNET
PAC-SC51KUA
M-NET
KNX-EIB CITY MULTI INTERFACESFUNCTION KNX-EIB-IP-15 KNX-EIB-IP-100 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISEDCONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm(WxDxH)
15
Yes (AG150 or GB50)
9 to 30VDC or 24VAC 0.5A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Ethernet via HUB
107x58x105
100
Yes (AG150 or GB50)
9 to 30VDC or 24VAC 0.5A
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Ethernet via HUB
107x58x105
ABB
Intelligent Buildings
Nova Controls Ltd
Siemens
*NOTE 1
KNX-EIB
KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION
FUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Fault Code
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
4 Character code - Indicates all unit alarms
-
Technical Information
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 BEM
S M
odbus
Split
s In
terf
ace
/
BEM
S K
NX
-EIB
Inte
rfac
es
RS485
BEMS KNX-EIB Splits Interface
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.
ProconTM KNX-EIB-A-1
KNX-EIB-A-1
KNX-EIB
KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION
FUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Fault Code
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC
Heating 17-28ºC
Auto 19-28ºC
Lo-Mi1-Mi2-Hi
4 Character code - Indicates all unit alarms
-
KNX-EIB SPLITS INTERFACEFUNCTION KNX-EIB-A-1 COMPATIBLE WITH
MAX No. OFINDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
1
No
M SeriesMr Slim
KNX (TP-1) EIB
60x25x48
ABB
Intelligent Buildings
Nova Controls Ltd
Siemens
Technical Information
Digital Input
Analogue Input
Analogue Input
Analogue Input
Digital Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Analogue Output
Page 301
Co
ntro
lsR
ange
Page 300
Technical Information
BEMS Trend Interface
Mitsubishi Electric and Synapsys Solutions have been working together for the last six years to offer very competitive solutions for Trend users. The IQ3 Excite Interface has been modified by Synapsys Solutions to work directly in conjunction with the AG150 and GB50 centralised controllers. This allows Trend users to easily integrate Trend systems with Mitsubishi Electric air conditioning.
IQ3 Excite
(must be supplied by Synapsys)
ETHERNET
PAC-SC51KUA
M-NET
*NOTE 1
Trend
IMPORTANT NOTE: The IQ3 Excite Interface can only be supported by Synapsys Solutions (Tel: 01273 831831)
TREND INTERFACESFUNCTION NETWORK VARIABLE POINT TYPE NOTES
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
4 Character code - Indicates all unit alarms
-
-
Switch
Knob
Knob
Knob
Digital Input
Knob
Digital Input
Switch
Knob
Knob
Knob
Digital Output
Knob
Sensor
Digital Output
Sensor
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
TREND INTERFACEFUNCTION IQ3 EXCITE COMPATIBLE WITH
MAX No. OF INDOOR UNITS
CENTRALISED CONTROLLERREQUIRED
POWER SUPPLY
COMPATIBILITY
BEMS CONNECTION
DIMENSIONS - mm (WxDxH)
50
Yes (AG150 or GB50)
240VAC
City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF
Ethernet via HUB
263x42x130
Trend only
Trend IQ3 Excite
BEM
S K
NX
-EIB
Split
s In
terf
ace
/
BEM
S Tr
end Inte
rfac
e
M2M INTERFACEFUNCTION DESCRIPTION
MAX No. OF INPUTS
MAX No. OF OUTPUTS
MAX No. OF INDOOR UNITS
SIM CARD
M2M SERVER HOSTING
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)
4 (volt free contact)
12 (pulse with modulation)
50
Vodafone Sim Card supplied with one year contract
First year free of charge
240VAC 2A
City Multi, Mr Slim and M Series
300x70x350
M2M INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE
Control
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Filter Sign
Monitor
On/Off
Mode Operation
Setpoint Adjustment
Fan Speed Control
Permit / Prohibit
Airflow Direction
Fault Code
Filter Sign
Room Temperature
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
Normal/Reset
Run/Stop
Cool / Dry / Heat / Auto / Fan
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Lo-Mi1-Mi2-Hi
On/Off, Mode, Setpoint
Horizontal - 60,80,100º swing
4 Character code - Indicates all unit alarms
-
-
NOTESUP TO 25 GROUPS UP TO 50 GROUPS
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
M2M - Machine 2 Machine Interface
To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platformallows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.
MEUK
M2M SERVER
Technical Information
GPRS
Maxi M2M-IP/50
DEMONSTRATIONVisit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
Maxi M2M-IP/50
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
Page 303
M2M
Inte
rfac
e /
M2M
Split
s In
terf
ace
Co
ntro
lsR
ange
Page 302
ProconTM Maxi M2M-IP/50
GB50ADA
GB50ADA
M2M SPLITS INTERFACEFUNCTION DESCRIPTION
MAX No. OF INPUTS
MAX No. OF OUTPUTS
MAX No. OF INDOOR UNITS
SIM CARD
M2M SERVER HOSTING
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)
4 (pulse with modulation)
16
Vodafone Sim Card supplied with one year contract
First year free of charge
240VAC 2A
Mr Slim and M Series via Procon A1M
255x60x180
DEMONSTRATION
To offer remote management of its air conditioning unitsto companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platformallows customers to integrate multiple sites into onenetwork. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.
M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE NOTES
ControlOn/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Time Zone Weekly scheduling available
Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -
Time Zone Weekly scheduling available
Technical Information
MEUK
M2M SERVER
GPRS
A1MMini M2M-A/16
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
Mini M2M-A/16
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
ProconTM Mini M2M-A/16
M2M - Machine 2 Machine Splits Interface
A1M
A1M A1M
Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)
DEMONSTRATION
The Micro M2M can monitor and control up to 8 splits systems. The Micro M2M cannot be connected to the M2M server but can be monitored and controlled using text messages (SMS).
M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE NOTES
ControlOn/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
M2M SPLITS INTERFACEFUNCTION DESCRIPTION
MAX No. OF INDOOR UNITS
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
8
10 to 28VDC 2.5A
Mr Slim and M Series via Procon A1M
70x51x105
TEXT MESSAGE EXAMPLES
REGISTER (FROM MOBILE PHONE)
MONITOR
CONTROL
FAULTS
ProconTM Micro M2M-SMS-A/08
M2M - Machine 2 Machine Splits Interface
SMS
Micro M2M-SMS-A/08
A1M A1M
A1M A1MMicro M2M-SMS-A/08
Technical Information
M2M
Split
s In
terf
ace
/ M
2M
Web
Scr
eensh
ots
Co
ntro
lsR
ange
To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can beregistered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number
To monitor the units, just text “STATUS” to the unit and the Micro M2M will reply with, for example:STATUS UNIT1: OK A1M COMMS: OK DRIVE:OFF ROOM TEMP:22 TEMP SETPOINT:20 MODE: AUTO FAN:HIGH
To switch the unit to heat mode, just text “SET” “unit name” and “HEAT” for example: “SET UNIT1 HEAT”
If the unit goes into fault, the Micro M2M will send a detailed text message, for example:STATUS UNIT1: FAULT A1M COMMS: FAULT CALL 0870 3000300 FOR ASSISTANCE
Page 305Page 304
M2M-Machine 2 Machine Web Screenshots
MEUK Website
M2M is accessible using MEUK website.
Login
A username and password is required to monitorand control sites.
Monitor Active Alarms and Sites
All sites are listed with active alarm sites.
Status
A site can be selected to monitor each system.
Set Parameters
Indoor unit and third party equipment can becontrolled from the Website.
Reports
Reports can be generated for analysis.
Dashboard
AG150/GB50 web pages are availablefor the air conditioning units
Administration
Using the administration level, the phone numbers and email of each duty engineer may be set and activated.
Technical Information
PROCONTM PANEL_RS_SMS
MAX No. OF INDOOR UNITS
FEATURES
POWER SUPPLY
COMPATIBILITY
DIMENSIONS - mm (WxDxH)
8
Buzzer / Fault LED / Auto/Manual override switch / Relay for fault output
240VAC 2A
Mr Slim and M Series via Procon A1M
253x90x180
TEXT MESSAGE EXAMPLES
REGISTER (FROM MOBILE PHONE)
SET UP USING A TEXT
To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can beregistered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number
Enter the number of units running, the number of days to switch over and the high temperature alarm, forexample: “BACKUP ON, 3, 7, 27” (“ON” to activate, “3” for 3 units running, “7” to switch over every 7 daysand “27” for the high temperature alarm [all the units will be switch ON])
Technical Information
ProconTM PANEL_RS_SMS
Run Standby Panel
The panel PANEL_RS_SMS replaces the previous run standby panels. The new panel is smaller and uses Micro M2Mtechnology. The panel can control up to 8 indoor units and will send a text message under fault condition. The PANEL_RS_SMS does not need the SIM card to run.
SMS
A1M A1MProconTM
PANEL_RS_SMS
Example: “BACKUP ON, 2, 1, 27” = 2 units running, change daily, high temperature 27ºC
2 units running, unit 3 and 4 are in standby
2nd day, the switching over is enabled. Unit 1 and 4are now in standby and Unit 2 and 3 are running
3rd day, the switching over is enabled. Unit 1 and 2are now in standby and Unit 3 and 4 are running
On the 3rd day, the unit 4 fails
The next unit in standby starts automatically. Unit 1 and 3 are running, 2 is in standby and 4 in fault
The 4th day, a high temperature is detected for instance 28ºC
All units will then start
Day 1
Day 2
Day 3
Day 3
Day 3
Day 4
Day 4
Unit 1 Unit 2 Unit 3 Unit 4
NOTE: The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper.
FUNCTION DESCRIPTION
Page 307
Co
ntro
lsR
ange
Page 306
Split-System A2M InterfacesThe City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.
FUNCTION
COMPATIBILITY
CONNECTION TO
MNET SETTINGS
DIMENSIONS - mm (WxDxH)
Mr Slim S Series / M Series Indoor Unit
Indoor Unit
Dip Switches
160x55x70
PAC-SF81MA
SPLIT-SYSTEM A2M INTERFACES
Mr Slim Outdoor Unit
Outdoor Unit
Rotary Switches
130x15x90
MAC-399IF
Technical Information
PAC-SF81MA
Run S
tandby
Pan
el /
Sp
lit-S
yste
m A
2M
Inte
rfac
es
Mitsubishi Electric Partner Programme
Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors
a totally new and unique set of benefits. There are two categories within the programme - Accredited
Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s
stage of growth. All customers signing up to the programme standards are committing to continued
training and professional development.
For more information please contact your local sales office
Mitsubishi Electric Training Options
Mitsubishi Electric has four state-of-the-art training suites based at different
locations around the country for your convenience. Providing training for
all levels of expertise, our courses are taught by experienced engineers,
with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089
Many of our systems have an energy label of A. These systems meet the criteria of the
Energy Technology List and hence could qualify for 100% first year enhanced capital allowances
(whole system cost and ‘reasonable’ cost of installation). For further information please
go to www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.
UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.
Note: The fuse rating is only a typical value, it is the responsibility of a
qualified electrician/electrical engineer to select the correct cable size
and fuse rating based on current regulation and site specific conditions.
the name Mitsubishi is
synonymous with excellence
Known the world over, Mitsubishi is a trusted global leader
associated with a variety of products and services. Founded
in 1921, Mitsubishi Electric quickly rose to the forefront of the
air conditioning industry - a position we still enjoy today.
Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the internal environment of any building, large or
small. It does not only provide cooling when required, but also heating and often hot water can
be supplied from the same system. Providing heating and hot water as part of an integrated
air conditioning system is far more efficient than traditional heating methods such as gas and as a result
reduced running costs and emissions can be realised. More and more people are experiencing the
benefits of comfortable working, living and leisure environments made possible with air conditioning.
As market leaders, we pride ourselves in providing high performance, competitive systems with
low running costs and emissions.
Environmental AwarenessMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy
and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of
our factories and UK operations are ISO14001 registered, the international standard that ensures
that we are fully aware of the environmental impact of all our processes and ensures we have
procedures in place to reduce them. However, we have gone far further than any accepted
minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future
that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further
as it looks to install behavioural change in our own operations and our wider sphere of influence
with contractors, consultants and end users. It looks to highlight the advantages and opportunities
provided, by ensuring all of our activities are undertaken with consideration to the environment.
We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise
awareness of energy use in Europe.
The Forest Stewardship Council (FSC) is an international network promoting responsible
management of the world's forest. The paper this catalogue is printed on supports the
development of responsible forest management worldwide. The wood comes from FSC
certified, well managed forests, company controlled sources and/or recycled material.
www.green-gateway.co.uk
www.sustenergy.org
www.mitsubishielectric.com/eco
Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects
Low unit height - minimal intrusioninto occupied space
Double thermostat function - control the temp via a sensorin the controller or the unit (wired remote controllers only)
I-Save - Recalls the preferred (preset) temperaturevia a single button
Catechin filter - improves air quality and preventsthe spread of bacteria and viruses within the room
Air Cleaning filter - catches dust particles andcontaminates, helping to keep the air fresh
Anti-Allergy Enzyme filter - artificial enzymecatalyst on the filament catches allergens
Swing Vane Mode
Auto Vane Shutter - when unit is switched offthe vane automatically closes
Wide Swing - distributes air laterally by up to 150º
Long Airflow Mode - particularly suitable foruse in long, narrow spaces
Infra-red remote controller
Optimised rotary or scroll compressor
Econo Cool - allows set temperature to be raised by 2ºCwithout any loss of comfort and a 20% gain in energy efficiency
Inverter control - adjusts performance to economically matchthe demand for heating or cooling
Auto-Restart
Quiet operation
72 different airflow patterns - 2, 3 or 4 way discharge
High ceiling compatibility through wide flow air outlets
Auto-Changeover
Hot Start - draught prevention
Factory charged refrigerant up to 30m
Standard filter
Optional high efficiency filter
Plasma Duo filter system
Quick clean design
Drain lift pump as standard
Optional drain lift pump
High external static pressure
Optional high static fan motor
Fresh air knockout
Branch duct knockout
Ceiling soiling prevention
Replace Technology available
Refrigerant volume check function
I-See Sensor
Duty Standby Operation
Corporate SalesTel: 0870 3000 070
Fax: 0870 3000 080
ScotlandTel: 01506 444960
Fax: 01506 444961
ManchesterTel: 0161 866 6060
Fax: 0161 866 6081
BirminghamTel: 0121 741 2800
Fax: 0121 741 2801
BristolTel: 01454 202050
Fax: 01454 202900
IrelandTel: +353 (0)1 419 8800
Fax: +353 (0)1 419 8890
email: sales@meir.mee.com
LeedsTel: 0870 3300 347
Fax: 0870 3300 348
London Central RegionTel: 0207 928 6810
Fax: 0207 928 6569
London North RegionTel: 01707 282480
Fax: 01707 282481
Sales Offices:
London South RegionTel: 01689 881030
Fax: 01689 881031
20
11
Air C
ond
itionin
g P
rod
uct C
ata
log
ue
After Sales Service: 0161 866 6089
email: air.conditioning@meuk.mee.com
web: www.mitsubishielectric.co.uk/aircon
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England
General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric
are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the
equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly
developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general
particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of
which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in November 2010 SAP No. 237005
Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers,
wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.
Air Conditioning Commercial Heating
Domestic Heating Photovoltaics
Wor ld ofMaking a
Dif ference
The Renewable Solutions Provider
2011 Air ConditioningProduct Catalogue
Features Key
top related