mock-up detector simulation 제 9 회 reno collaboration meeting

Post on 03-Jan-2016

39 Views

Category:

Documents

4 Downloads

Preview:

Click to see full reader

DESCRIPTION

Mock-up detector simulation 제 9 회 RENO collaboration meeting. I. S. Jeong*, C. W. Park RENO Collaborators. Contents: 1) MockUp Introduction 2) Structure Summary a. Bridges(Target, Gamma-Catcher) b. Chimney(Short Chimney) c. PMT Holder d. Baffle - PowerPoint PPT Presentation

TRANSCRIPT

Mock-up detector simulation

제 9 회 RENO collaboration meeting

I. S. Jeong*, C. W. ParkRENO Collaborators

Contents:1) MockUp Introduction2) Structure Summary a. Bridges(Target, Gamma-

Catcher) b. Chimney(Short Chimney) c. PMT Holder d. Baffle e. Updated Version(Optional) f. New Positioning 3) Analysis(Quick-Check)

MockUpDefinition of MOCK-UP: In common usage, a mockup is a scale model of a structure or device, usually used

for teaching, demonstration, testing a design, etc. - WIKIPEDIA

Figure 1.RENO Main(full-sized) detector

Figure 2.RENO Mock-Up detector

Name Material

OV IV NV Rho M

liter liter liter g/cm3 Kg

MockUp Target 170 151

MockUp GC 1186.9

1194

MockUp Detector

7892

Bridge(Target)

290mm

G4double tXaxis0 = 216.5 G4double tXaxis1 = 0 G4double tXaxis2 = -216.5 G4double tXaxis3 = -216.5 G4double tXaxis4 = 0 G4double tXaxis5 = 216.5

G4double tYaxis0 = 125G4double tYaxis1 = 250G4double tYaxis2 = 125G4double tYaxis3 = -125G4double tYaxis4 = -250G4double tYaxis5 = -125

Target Position(Z=-445mm)

Unit:mm

confirmation

Bridge(Gamma-Catcher)

Curvature

Height and width

Radius

Radius of buffer tank: 1100mm

√Gap Between bridge & Stainless steel: 5mmGamma-Catcher Bridge Length: 490mm → 495mm

Thickness of stainless steel:5mm

Implementation

G4double gXaxis0 = 357.2G4double gXaxis1 = 0G4double gXaxis2 = -357.2G4double gXaxis3 = -357.2G4double gXaxis4 = 0G4double gXaxis5 = 357.2

G4double gYaxis0 = 206.23G4double gYaxis1 = 412.5G4double gYaxis2 = 206.23G4double gYaxis3 = -206.23G4double gYaxis4 = -412.5G4double gYaxis5 = -206.23

Gam

ma-C

atc

her

Posit

ion

(Z=

-850m

m)

Chimney(Short Chimney)

Short ChimneyMiddle Chimney

PMT Holder

Prototype Holder Test in the Drum

Holder Parameter

Realistic Holder

PMT middle holder’s design confirmation

d:depthD:DiameterH:HeightT:Thickness

37.1847°

Baffle(Top,Bottom)

Top Baffle

Bottom Baffle

Confirmation

After adjustmentTop & Bottom

Baffle(Side)

Side

Side Baffle

CABLE WAY

Updated Version(Optional) Baffle – Cont’ More Realistic for the Top

CABLE WAY

Updated Baffle(Top)

277mm

231.5mm

New Positioning for the Baffle Analysis

• Because Baffles is over the buffer region,we couldn’t know how it run.

Baffle 이 Buffer 를 넘어버려 이들의 Effect 를 볼 수 없음

Etc(Viton Analysis) - ready

SiliconPAD 가 없을 경우

SiliconPAD 가 있을 경우

Viton 에 대한 geometry

P.E. Analysis(Quick-Check)

1) Nothing2) Only Target Bridge

3) Only Gamma-Catcher Bridge4) All Bridge

5) Only Holder6) Only Baffle

7) Holder & Baffle

Bridge Analysis

Nothing

Only Target

Only Gamma-Catcher

All Bridge

Status Photoelectron

Nothing 739.7 0.6

Only Target 746.7 0.6

Only Gamma-Catcher

742.3 0.6

All Bridge 747.5 0.6

Holder & Baffle Analysis

Only Holder

Only Baffle

Baffle with Holder

Status Photoelectron

Only Holder 721.2 0.6

Only Baffle 728.2 0.6

Baffle with Holder

714.6 0.6

Offset Analysis

+ 10mm offset

- 20mm offset

Source Calibration( Ge)68

SummaryChimney, Bridge(Target, Gamma-Catcher),

Holder, Baffle, Viton 등 축소형 검출기를 위한 MC 에

모두 구축되어 있음 (cable 제외 )

Todo listMC(for MockUp) Stability Check

Energy, Vertex Calibration using the Source(Co137, Ge68...)

Backup

Quick ComparisonWithout Bridge

With Bridge

TYVEKWithout TYVEK(X-axis) With TYVEK(X-axis)

Without TYVEK(Z-axis) With TYVEK(Z-axis)

Overlapped noTYVEK(X & Zaxis) Overlapped TYVEK(X & Zaxis)

top related