monavisa en

Post on 19-Dec-2014

116 Views

Category:

Technology

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

 

TRANSCRIPT

10-04-23

“Always a foot step ahead”“Good stewardship is a mission”

1. What?

• Insight in installation/buildings:– operating– discrepancies– origin of discrepancy

• Easy (visually)

• Effective (quick + good value for money)

10-04-23 3

2. Why?

• To prevent for complaints (comfort) and problems (legionella, imbalance etc.)

• To satisfy legal obligations (seasonal thermal storage etc.)

• To make agreements with maintenance companies (performance contracting)

• Improving more complex installations

• Short term anticipation

• Functional interventions

• Business cases / ESCO / DBFMO

10-04-23 4

10-04-23 5

3. Principle?

• Terms: BMS history (independent of any BMS manufacturer) or equivalent (direct connection to IP BMS parts) and internet connection

10/04/23

• Data:– Generation

– Analysis

– Evaluate (experience)

6

Component specification

10-04-23 7

Mapping BMS-data

10-04-23 8

Calculations

10-04-23 9

Review

10-04-23 10

4. Who’s determining the KPI’s?

The customer determines the terms wherein will be steered

Themes Key Performance Indicators:•Energy

•Comfort

•Installation (condition)

•Process

•Data

10-04-23 11

5. What does Monavisa?

Sending

•the right information

•at the right time

•to the right persons

(webportal and/or e-mail)

10-04-23

“Monavisa decreases the time and simplifies the knowledge to manage the installation”

12

10-04-23 13

6. The modules

• Performance management (energy, comfort, installation, process and/or bonus-malus)

• Energy mirror

• Seasonal thermal storage

• Legionellosis

• Processing folder

10-04-23 14

Performance management

10-04-23 15

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

16

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

17

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

18

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

19

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

20

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

21

Climaventa heat pump KSH - contribution in heat supply is too low (46 hours) Climaventa heat pump TTH - contribution in heat supply is too low (66 hours)

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

22

10-04-23

Input seasonal thermal storage

decreases by start cooling

machine!

Dashboard Details Reports Analysis Report Registration Bonus-Malus

23

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

24

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

25

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

26

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

27

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

28

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

29

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

30

10-04-23

Dashboard Details Reports Analysis Report Registration Bonus-Malus

31

Energy mirror

10-04-23 32

Seasonal thermal storage

10-04-23 33

Seasonal thermal storage

10-04-23 34

Seasonal thermal storage

10-04-23 35

Legionellosis

10-04-23 36

Legionellosis

10-04-23 37

10-04-23

Building folder

38

7. What is the added value?

• Bright use of available data

• Continuous control of performance (24/7)

• Practically and experience based

• Uses already available data (less is more)

• Connection with all BMS-systems via every protocol possible

• Custom-made reports

10-04-23 39

8. Users

10-04-23 40

• Building owners

– Municipalities

– Banks

– Schools

– Hospitals

– Housing associations

– Dutch government

• Energy suppliers

• Construction companies

– Installation companies

– BMS-suppliers

• Facility service companies

10-04-23 41

Mr Kircadag is Technical Manager at the Amsterdam Universityy of applied sciences and responsible for building’s installation operation and maintenance on several locations.

‘It has assisted us to optimise’

‘Monavisa provides provides daily insights into the technical installation. Discrepancies will automatically reported and it gives a quick overview on status.’

9. Example: location Schiphol ( app. 700.000 – 800.000

m2)

10-04-23 42

Case: TransPort

10-04-23 43

Case: B-pier

10-04-23 44

Input seasonal thermal storage decreases by start cooling

machine!

44

Case: Outlook

Case: KLM 410

More information

Wilfred van der Plas

+31 (0) 6 52 39 01 31

plas@dwa.nl

10-04-23 47

top related