FCAT1000-N
Installation and User Guide
-
Copyrights
This manual and the information contained herein is proprietary information and is intended for the exclusive use of MRO-TEK customers. The
information in this manual should not be copied, distributed, shared or reproduced in any manner without the express written permission of
MRO-TEK. Information contained in this document is subject to change. In the event of a change, this document will be revised.
Restrictions
The software described in this document is the property of MRO-TEK. It is furnished under a license agreement and may be used and/or disclosed
only in accordance with the terms of the agreement. Software and documentation are copyright materials. Making unauthorized copies is prohibited by
law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language
or computer language, in any form or by any means, without prior written permission of MRO-TEK.
Accuracy
While reasonable efforts have been made to assure the accuracy of this document, MRO-TEK assumes no liability resulting from any inaccuracies or
omissions in this document, or from the use of the information obtained herein. MRO-TEK reserves the right to make changes to any products
described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in
content hereof with no obligation to notify any person of revisions or changes. MRO-TEK does not assume any liability arising out of the application
or use of any product or circuit described herein; neither does it convey license under its patent rights of others.
Trademarks
MRO-TEK and the MRO-TEK logo are registered trademarks of MRO-TEK Limited.
All other brands and corporate names are trademarks of their respective owners.
MRO-TEK LTD. Bellary Road, Hebbal, Bangalore - 560 024, INDIA Ph: +91 80 2333 2951 Fax: +91 80 2333 3415 Email: mrotek@vsnl.com Web: www.mro-tek.com
-
Version status of this manual
The following shows the issue status of this manual since its release.
Version information
The following lists the versions of this manual in order of manual release:
Table 1 Version information
Manual version
Date of release e Remarks
1.0 July 2010 Original Issue 1.0
1.1 December 2010 60Km Optics information update
1.2 October 2012 MROTEK revised logo for 2012
Text conventions
In the manual, new and amended features are tagged to help users to assess the impact. The tags include index references which are listed in the manual Index.
Table 2: Text convention
ICON Notice Type Alerts
NOTE
Important feature or instruction.
Caution
Risk of personal injury, system damage, or loss of data
Warning
Risk of severe personal injury
The tags are positioned in text as follows:
Cross references
Throughout this manual, references are made to external publications, chapter numbers and section names. The references to external publications are shown in italics, chapter and section name cross references are emphasized in bold.
2010
All Rights Reserved
-
Table
of Contents
Contents FCAT1000-N
Chapter 1 Overview of FCAT1000-N ......................................................................................................... 1-1 Introduction................................................................................................................................................................. 1-2
Specification ....................................................................................................................................................... 1-2 Fiber Optic Specifications ................................................................................................................................... 1-3 Features.............................................................................................................................................................. 1-3 Physical Description............................................................................................................................................ 1-4
Chapter 2 Installation and Setup.................................................................................................................. 2-1 Installation .................................................................................................................................................................. 2-2
Package Content ................................................................................................................................................ 2-2
Installing FCAT1000-N ..................................................................................................................................... 2-2 Site Requirement and prerequisites.................................................................................................................... 2-2 Connecting the interfaces ................................................................................................................................... 2-3 Connecting to Power........................................................................................................................................... 2-3 Connecting the Ethernet Interface ...................................................................................................................... 2-3 Connecting the SC Interface............................................................................................................................... 2-4 Application .......................................................................................................................................................... 2-4
Chapter 3 Operation ...................................................................................................................................... 3-1
Operating FCAT1000-N........................................................................................................................................... 3-2
Turning on FCAT1000-N .................................................................................................................................. 3-2 LED Indicators .................................................................................................................................................... 3-2 DIP Switch .......................................................................................................................................................... 3-3
Installation .................................................................................................................................................................. 3-4
Chapter 4 Appendix A ................................................................................................................................... 4-1 Safety Notices ............................................................................................................................................................ 4-2
Safety Precautions.............................................................................................................................................. 4-2 Modifications to Equipment................................................................................................................................. 4-2 Placement of the unit .......................................................................................................................................... 4-2
Chapter 5 Appendix B ................................................................................................................................... 5-1 F.A.Q.......................................................................................................................................................................... 5-2
i
-
List of
Figures
List of Figures Figure 1: FCAT1000-N ...................................................................................................................................................1-4
Figure 2: Front Panel of FCAT1000-N media converter .................................................................................................2-3 Figure 3: Application..........................................................................................................................................................2-4 Figure 4: Front Panel LED indicators ................................................................................................................................3-2
ii
-
List of Tables Table 1 Version information ................................................................................................................................................. 1 Table 2: Text convention...................................................................................................................................................... 1
1-1
-
Chapter 1 Overview of FCAT1000-N
1-1
-
Introduction FCAT1000-N
Introduction
The FCAT1000-N is a single channel stand-alone Media converters provide media conversion from 1000Base-TX to 1000 Base-FX on multimode or single mode fiber up to 60kms. Available in Stand-alone, internal auto ranging AC/DC Power supplies and a versatile range of Fiber Optic interfaces, FCAT1000-N becomes a complete offering to suit Carriers, Service Providers and Enterprises for wide range of deployments.
It is an Unmanaged Gigabit Ethernet Media converter, which supports a variety of advanced features and flexible interface options, giving service providers the power to quickly and profitably deploy Ethernet services. Enterprise customers can leverage existing Gigabit Ethernet infrastructure for long haul connects.
FCAT1000-N is a rugged and reliable Gigabit Ethernet media converter providing seamless extension of Gigabit Ethernet on single mode/multi mode fiber up to 60 kms. It is very flexible and it adapts to different connectivity needs make this product an essential component of any network design.
Specification
Standards Compliance IEEE 802.3ab, IEEE 802.3z
1000BASE-TX, 1000BASE-FX
1000BASE-TX port: Shielded RJ-45
Duplex support Half/Full
Auto MDI-I / MDI-X
1000Base-FX port SC connector
LED Indicators
PWR (green) Power status
Link(LNK) Link Status for Ethernet ports
Activity (ACT) Activity status for Ethernet ports
LFP Link Fault Propagation Indication for Ethernet ports
FEF Far End Fault Indication for Ethernet ports
DIP Switch
SW1 Link Fault Enable/Disable
SW2-SW4 Not Connected
Power
Stand-alone
AC 100 to 240 VAC, 1.85 W
DC -36 to -72 VDC, 1.85 W
1-2
-
FCAT1000-N Introduction
ENVIRONMENTAL
Operating temperature 0 to 50 C (32-122 F)
Storage temperature -30 to 65 C (-22 to 149 F)
Humidity 10 to 90% Non-condensing
Fiber Optic Specifications
Module Type
Wavelength (nm)
Fiber Type (m) Typical Tx Power (dBm)
Typical Rx Sensitivity (dBm)
Typical Range (Kms)
MM 850 62.5/125 Multimode -6 -14 0.22
MM 850 50/125 Multimode -6 -14 0.5
SM10 1310 9/125 Single mode -6 -18 15
SM40 1310 9/125 Single mode 1 -19 40
SM60 1550 9/125 Single mode 0.5 -20 60
SF15 1310/1550 9/125 Single mode SF -6 -18 15
SF40 1310/1550 9/125 Single mode SF 0.5 -19 40
Features
Single channel standalone media converter Media Conversion from 1000BASE-TX to 1000BASE-FX Auto MDI-I/MDI-X copper Ethernet port RJ-45 connector for 1000BASE-TX port SC connector for 1000BASE-FX port Link and Activity, FEF, LFP LED indications FEF indication for both remote side fiber and copper LFP propagation of both from copper to fiber and fiber to copper Supports multi mode or single mode fiber Single mode option available up to 60 km Internal auto-ranging AC or DC power supply Configuration using DIP Switches
1-3
-
Introduction FCAT1000-N
Physical Description
Figure 1 shows a 3D view of the FCAT1000-N unit in the enclosure.
The front panel of a desktop unit includes SC connector, Copper Ethernet port and several LED indicators which display the status of power, link and activity indicators.
Figure 1: FCAT1000-N
1-4
-
Chapter 2 Installation and Setup
2-1
-
Installation FCAT1000-N
Installation
This chapter describes installation and setup procedures for the standalone FCAT1000-N media converter.
Internal settings, adjustment, maintenance and repairs may be performed only by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation and maintenance of this product.
The FCAT1000-N media converter is designed for standalone installation and is delivered as a fully assembled unit.
Package Content
The FCAT1000-N package includes the following items:
One FCAT1000-N unit Technical documentation CD AC or DC power cords
Installing FCAT1000-N
The installation of the FCAT1000-N media converter includes the following steps,
Connecting the unit to power mains Connecting the SC interface Connecting the Ethernet interface
Site Requirement and prerequisites
AC-powered FCAT1000-N units should be installed within 1.5m (5 ft) of an easily-accessible grounded AC outlet capable of furnishing the voltage in accordance with FCAT1000-N nominal supply voltage.
DC-powered FCAT1000-N units require a -36 to -72 VDC power source, which must be adequately isolated from the main supply.
The ambient operating temperature of FCAT1000-N should be 0 to 50C, at a relative humidity of up to 90%, non-condensing.
2-2
-
FCAT1000-N Installation
Connecting the interfaces
Figure 2 shows a typical front panel of FCAT1000-N media converter with an Ethernet interface, SC interface and power LED.
Figure 2: Front Panel of FCAT1000-N media converter
Connecting to Power
FCAT1000-N is equipped with either AC or DC power supply. AC or DC power is supplied to FCAT1000-N via a standard power input connector on the rear panel.
Connecting to AC Power AC power should be supplied through the standard power cable terminated by a standard plug. The AC power chord is provided along with the unit.
To connect AC power:
1. Connect the power cable to the power connector on the FCAT1000-N rear panel.
2. Connect the power cable to the mains outlet.
The unit turns on automatically upon connection to the mains.
Connecting to DC Power DC power is supplied to FCAT1000-N via a compatible DC cable for attaching -48V DC power supply lines. While connecting to the DC power mains, the polarity needs to be taken care as per the indications provided on the DC cable.
The DC power cord is provided along with the unit.
Connecting the Ethernet Interface
Ethernet interface uses RJ45 connector
To connect Ethernet interface
Connect the line cable to the RJ-45 connector designated to Ethernet interface.
2-3
-
Installation FCAT1000-N
Connecting the SC Interface
The FCAT1000-N has SC interface.
To connect SC interface
Connect the cable to the designated SC interface located on the front panel.
Application
The below figures illustrates FCAT1000-N applications, It is designed for demanding network
environments to provide high speed and reliable connects. It can typically be used in a LAN,
MAN or in a Campus Network.
Figure 3: Application
2-4
-
Chapter 3 Operation
3-1
-
Operating FCAT1000-N FCAT1000-N
Operating FCAT1000-N
This chapter provides the following information for FCAT1000-N Media converter
Operating procedures (Power-ON, Performance Monitoring and Power-OFF) FCAT1000-N LED indicators
Turning on FCAT1000-N
To turn on FCAT1000-N:
Connect the power cord to the AC/DC power mains. The PWR indicator lights up and remains lit as long as FCAT1000-N is receiving power.
FCAT1000-N requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators. Intervention is only required when FCAT1000-N needs to be configured to its operational requirements or diagnostic tests to be performed.
LED Indicators
The front panel of FCAT1000-N includes a series of LED indicators that shows the current operating status of the unit.
LED Indicator description Figure 5 shows the front panel of FCAT1000-N unit.
Figure 4: Front Panel LED indicators
3-2
-
FCAT1000-N Operating FCAT1000-N
Interface Type
Color Indicat
or Name
Indicator Meaning
Function
Power Supply
Green PWR Power Indicator ON: Unit is powered ON
OFF: Unit is not receiving Power
Activity Green ACT Activity status Flashing: Activity status for Ethernet port
TX-LNK
Copper Link ON: Copper Link is active
Link Green FX-LNK
Fiber Link ON: Fiber Link is active
TX-LFP Link Fault
Propagation in Copper
ON: LFP in Copper
LFP Green
FX-LFP Link Fault
Propagation in Fiber
ON: LFP in Fiber
TX-FEF Far End Faul
Copper t ON: FEF in Copper
FEF Yellow
FX-FEF Far End Fault
Fiber ON: FEF in Fiber
DIP Switch
SW1: Link Fault Enable/Disable
SW2-SW4: Not Connected
3-3
-
Installation FCAT1000-N
Installation
Following are the installation procedure to install FCAT1000-N
1 Connect a fiber patch chord Type (single/multi mode) and SC interface on FCAT1000-N to the FX port.
2 Connect a CAT 5 UTP cable to the corresponding TX port and terminate it on the Ethernet port of the terminal equipment (Typically a switch/PC/server)
3 Repeat step two at the remote side of the fiber.
4 After switching on, check if the FX link is up, or else swap TX and RX patch chord of the corresponding FX port.
5 Once FX link is up, check the TX link status and ensure it is up.
3-4
-
Chapter 4 Appendix A
4-1
-
Safety Notices FCAT1000-N
Safety Notices
For your protection, observe the following safety precautions when setting up your equipment:
Safety Precautions
Read the following safety information thoroughly before installing the FCAT1000-N.
Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product.
No User-serviceable parts in the equipment. Installation and removal of module should be done by qualified personnel only. Follow all cautions and instructions if marked on the equipment supplied. Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is
not responsible for regulatory compliance of a modified MRO-TEK Limited product.
Never place an MRO-TEK Limited product near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of the device.
Modifications to Equipment
Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is not responsible for regulatory compliance of a modified MRO-TEK Limited product.
Placement of the unit
Do not block or cover the opening vents of your purchased product. Never place the unit near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of the device.
4-2
-
Chapter 5 Appendix B
5-1
-
FCAT1000-N
F.A.Q
Problem Indication Corrective Action
Check if the power supply cable is firmly connected to the main power supply
Check if the AC input power source is between 100 and 240VAC. (Check if the source voltage is between 36VDC to 72VDC for a DC Box)
No Power Main power
LED is not glowing
Check the fuse on AC mains supply
Check whether the connected devices port is active.
Check if the cable is faulty.
Copper link not active
TX Link LED is not glowing
(TX LINK) Reset the device and try again
Check if the receive fiber of the local device is properly connected to the transmit port of the remote fiber device and the transmit port to the receive port of the remote device
Ensure that the cables are inserted properly.
Check whether the connected remote device is active.
If the problem persists, then repeat the above-mentioned steps at the remote device.
If the link still does not come up, ensure that the fiber link is functional, using an OTDR equipment measure the fiber loss and ensure that the loss is less than the product power budget.
Fiber link not active
FX Link LED (1000Base-FX is not glowing)
Reset the device and try again
Improper network traffic / slowed down traffic
Excess collisions Verify that all devices (both FCAT and the devices interconnected by them) are set to the same Duplex mode, 1000 Mbps data rate, and set to Auto negotiation enable.
5-2
CopyrightsVersion status of this manualVersion informationText conventionsCross referencesContentsList of FiguresList of Tables
Chapter 1 Overview of FCAT1000-NIntroductionSpecification Fiber Optic SpecificationsFeatures Physical Description
Chapter 2 Installation and SetupInstallationPackage ContentInstalling FCAT1000-NSite Requirement and prerequisites Connecting the interfacesConnecting to PowerConnecting the Ethernet InterfaceConnecting the SC InterfaceApplication
Chapter 3 OperationOperating FCAT1000-NTurning on FCAT1000-N LED IndicatorsDIP Switch
Installation
Chapter 4 Appendix ASafety NoticesSafety PrecautionsModifications to EquipmentPlacement of the unit
Chapter 5 Appendix BF.A.Q