nextseq sequencing run monitoring · 2017-09-21 · •intensity, cluster density and q scores are...

Post on 02-Aug-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

© 2015 Illumina, Inc. All rights reserved.

Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cBot, CSPro, CytoChip, DesignStudio, Epicentre, ForenSeq, Genetic Energy, GenomeStudio, GoldenGate, HiScan, HiSeq,

HiSeq X, Infinium, iScan, iSelect, MiSeq, MiSeqDx, MiSeq FGx, NeoPrep, NextBio, Nextera, NextSeq, Powered by Illumina, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG,

VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or i ts affiliate(s) in the US and/or other countries. All other names, logos, and

other trademarks are the property of their respective owners.

NextSeq Sequencing

Run Monitoring

2

By the end of this training, you will be able to:

– List the three options to monitor a run

– Describe the functionality of SAV

Session Objectives

3

NextSeq Run Monitoring

Sequencing Screen in NCS

Monitor:

-On-instrument analysis

-Intensities Quality Scores

Sequencing Analysis Viewer

(SAV) in BaseSpace

Monitor run in greater detail

Sequencing Analysis Viewer

(SAV)

Monitor run in greater detail

4

Viewing Run Metrics using

NextSeq Control Software

5

NCS during On-Board Cluster Generation

6

Note: Population of run metrics may be delayed by a couple of cycles due

to processing events

Run progress:• Status bar lists completed

cycles.

• Includes steps for

clustering, Read 1, Index 1

Read, Index 2 Read, Read

2, and the post-run wash

directly following the run.

A

B Q-Score:• Cycle 25

C Intensity: • Cycle 25

D Cluster Density (K/mm²):• Cycle 25

E Clusters Passing Filter:• Cycle 25

F Estimated Yield (Mb):• Cycle 25

G Flow Cell:• Shows which lane pair is

being imaged and on which

lane pair chemistry is being

performed.

Viewing Run Metrics on the Sequencing Screen

7

Viewing Run Metrics using Sequencing

Analysis Viewer

8

Sequencing Analysis Viewer

Files used by SAV

runinfo.xml

runparameters.xml

Interop files

Thumbnail files (optional)

Data Availability

Intensities after Cycle 25

Phasing/Prephasing after Cycle 25

Clusters Passing Filter (PF) after Cycle 25

Quality scoring after Cycle 25

PhiX alignment and error rates after Cycle 26

9

SAV: Tabs

Run Metrics can also be reviewed offline from

any computer with access to the run folder

10

SAV: Drop-down Options

Drop-down Options

11 COMPANY CONFIDENTIAL – INTERNAL USE ONLY

SAV: Summary

12

SAV: Imaging Tab

13 COMPANY CONFIDENTIAL – INTERNAL USE ONLY

SAV: Indexing Tab

The Indexing tab is only available if the run is an index run

Note: For NextSeq data, indexing can be viewed in BaseSpace

after run completion or in SAV only after bcl2fastq2 conversion

14 COMPANY CONFIDENTIAL – INTERNAL USE ONLY

Viewing Run Metrics using Sequencing

Analysis Viewer in BaseSpace

15

BaseSpace: Charts

16

BaseSpace: Run Summary

17

Summary of Run Monitoring

• Intensity, cluster density and Q scores are available during the run

Sequencing run metrics can be viewed on NCS during a run

• During a run and after a run has completed

• Provide more metric options than NCS

Sequencing run metrics can be viewed remotely using SAV at anytime

• Cycles 25 through run completion: Intensity, Cluster Density, % PF, Yield, Q scores

Run metrics are populated after cycle 25 in SAV during a run

• Trending of run metrics is highly recommended to identify outliers

Absolute or relative values for run metrics will be dependent on the type of library

18

Online Training

• Sequencing Analysis Viewer (SAV)

• NextSeq 500: Does My Run Look Good?

Documentation

• Sequencing Analysis Viewer User Guide

NextSeq 500 Run Monitoring Resources

19

Questions?