Post-PFC DC-DC Converter Design Considerations to Meet Wide Load
Current Efficiency Goals
Rais Miftakhutdinov
Texas Instruments, High Performance Isolated Power,South-East Design Center, Cary, North Carolina
r-miftakhutdinov1@ti.com
2011 IBM Power Technology Symposium
2
Outline Energy Saving and Power Supply Efficiency related Standards
Benchmark Design Goals: Efficiency, Power Density, Cost
Phase-Shifted Full-Bridge Post-PFC Converter
Optimal Design Procedure and Power Saving Algorithm
Analog and Digital Controllers to meet Power Saving Goals
MathCAD and SIMPLIS based Design Tools
Prototype Example and Measured Performance
Summary
2
3
Strive for Efficiency and Power SavingTelecommunication industry consumes 1% of electrical energy worldwide that equals to 160 Billions kWh [1]
International Telecommunication Union (ITU) estimates that Information and Communication Technology contributes 2.5% into the worldwide greenhouse gas emission:
http://www.itu.int/themes/climate/events/cop16/sg.html
Worldwide movement for energy saving and “Green power”generation and distribution, have resulted in number of voluntary initiatives and mandatory regulations by international and government organizations for increased efficiency of electronic equipment including data and telecommunication power systems. Examples of such organizations and initiatives are United StatesENERGY STAR® program, German Blue Angel, Japan Environment Association, European Code of Conduct and others [2].
USA Energy Star
German Blue Angel
Japan Environment Association European
Code of Conduct
China Energy Conservation
ProjectKorea Energy Management
Corp
CA Energy Commission
4
Energy Star® for Server Power Supplies, ver. 1, May 15, 2009
88%92%88%80%> 1000 W
85%89%85%75%> 500 – 1000 W
85%89%82%70%≤ 500 WSingle-Output (AC-DC & DC-DC)
82%85%82%N/AAll Output Levels
Multi-Output (AC-DC & DC-DC)
100% Load
50% Load
20% Load
10% Load
Rated Output Power
Power Supply Type
Energy Star® minimum efficiency requirements for 12-V output server power supplies at 10%, 20%, 50%, 100% load and 230 V AC line [7].
3
5
0.95 @ 50% load
0.9 @ 50% load
0.9 @ 50% load
0.9 @ 50% load
PF
91%88%85%81%100% load
94%92%89%85%50% load
90%88%85%81%20% load
“80 PLUS” and “Climate Savers Computing”
“Climate Savers Computing” initiative requires servers to meet “Energy Star®” specification and the power supply to be certified in accordance to “80 PLUS” requirements.
[8] http://www.plugloadsolutions.com/80PlusPowerSupplies.aspx
[9] http://www.climatesaverscomputing.org/
6
Design Goals for Front-End Power Supply
Efficiency: 96.5% at half and 95.4% at full load for telecom rectifier 94% at half and 92% at full load for server power supply
Power Factor: 0.95 at half-load and full load Power Density: >40 W/cub.inch Cost per Watt: <10 cents/W Design Cycle from Spec to Volume Production: < 8 Months
Facility208V AC AC/DC
(PFC)DC/DC
12V DC (server)
-48V DC (rectifier)
PSMA Power Technology Road Map 2009: http://www.psma.com/
4
7
80+ “Platinum” Server Power Supply Efficiency Breakdown
0.950.950.900.80Power Factor
97.6
96.9
94
50%
97.796.495.3PFC
94.495.892DC-DC
929185.7AC-DC
100%20%10%Pout
Efficiency and Power Factor goals for “Platinum” Power Supply
“Platinum” 80+ requirements for server power supply are most challenging. Below is efficiency breakdown between PFC and DC/DC parts of Front-End AC/DC server power supply
8
Post-PFC DC/DC Converter Topologies Comparison
• Duty cycle range is limited
• Difficult to maintain ZVS at wide input voltage range
• Mature ZVS topology for one channel
• Simple control and minimum number of components
• Easy interleaving of any number of channels
•Scalable and efficient over wide load current range
Interleaved Assymm. Half-Bridge
• Difficult for interleaving and synchronization
• Frequency control
• Large ripple current through capacitors
• Non-trivial for optimal design
• Short circuit issue
•At wide input voltage range the efficiency degrades because of circulating current during the freewheeling stage-
• ZVS and ZCS of major switches
• Lower rated voltage Sync FETs
• Highest efficiency at maximum Vin, which is good for post-PFC converter
•Low EMI
• Mature ZVS topology
• Interleaving capability
• Improved modifications available using the same control
• Fixed frequency PWM
•Can be designed to operate in different power saving modes
+
LLC ConvertersPhase-Shift Full Bridge
5
9
Phase Shifted Full Bridge Converter
Soft switching (ZVS) No snubbers on primary side High frequency
Highest efficiency
Low EMI while ZVS is maintained
Complex control
10
Considerations for Highest Efficiency over Whole Load Range
- Vout +12V
Vin330V to 380V(420V peak)
+
_
Q1
Q11Q22
Q2
Q3 Q4
Llk=10μH
Lμ=736μH
Rpr=37.8mΩ
24T
1T 1TTr
Co = 8,000μF
Q1, Q2, Q11, Q22: IPB50R250CP, Rdson=0.22Ω typ.
Q3, Q4: 3 in parallel each,
IRF7749L2TRPbFRdson =1.1mΩ
A B
Coss
CossCoss
Coss
Optimal ratio between conduction and switching losses while FETs selection
Primary FETs with low Coss
Transformer with optimal turns ratio, Ls and Lµ to achieve ZVS
Synchronous rectification on secondary side
Adaptive optimal switching timing for all primary and secondary FETs
Optimal output inductor to set boundary between CCM and DCM mode
Optimal light load management algorithm
[3]…[6]
6
11
Optimal Design Procedure Select ZVS allowing topology and number of channels based on efficiency design goals and output power level
Optimize maximum efficiency point location where switching and conduction losses ratio are equal and select power switches and magnetics accordingly
Find optimal Ls and Lµ to maintain ZVS over entire load current range
Identify optimal DCM, Diode rectification and “Burst” mode regions, and phase shedding boundaries if multi-channel topology is selected
Estimate optimal switching timing for all FETs as function of operating conditions
Design cycle might take few iterations, so the use of design support software is very helpful
12
Optimal Pcond/Psw Selection with MathCAD
Dots show efficiency design goals
Pcond low, Psw high
Pcond & Psw optimal
Pcond high, Psw low
Optimal light load management in this region
7
13
Optimal Light Load ManagementMoving into DCM mode, sync. FETs in diode emulation mode, D significantly depends on load
0 1 2 3 4 5 6 7 8 9 100
0.2
0.4
0.6
0.8
VsminVsmax
Load Current, A
Dut
y C
ycle
Setting Dmin=15.6%
Burst Mode Area
The region below DCM is identified where the diode emulation is maintained
Diode rectification region is where synchronous MOSFETs drive losses become burden
At very light current it is beneficiary to operate in “burst” mode to reduce power losses even further. Simplest way to operate in “burst” mode is by limiting minimum duty cycle
Diode rectification mode
14
Power Saving Control Algorithm vs Load Current
Nominal Operation at Io from 20 to 100%
Transition Mode at Io from 10 to 20% by gradually reducing synchronous FETsconduction time
Diode rectification with DCM at Io <10%
Burst Mode at no-Load or very light load
8
15
Suggested Optimal Power Management Algorithm
16
UCC28950 Phase-Shifted Controller Utilizing Power Saving Algorithm
Accurate, adaptive ZVS timing over wide operating range as function of current sensing signal
MOSFET Rectifier Outputs synchronized with primary switching as function of current sensing signal
Light Load Power Management Block
Vin
+
_
Vout
+
_
Enable
UCC28950
Vdd
Vdd
Vdd
Vdd
CT
Vdd
SYNC
QA
QB
QC
QD
QE QF
18
19
OUTE
4
RSUM
6
3
7
20
1
2
21
5
22
23
24
COMP
SS/EN
SYNC
VREF
TMIN
VDD
OUTA
OUTC
OUTD
OUTB
GND
EA+
DELCD
9
8
15
16
17DELEF
EA-
CS
ADEL
ADELEF
OUTF
DELAB
DCM
10
11
12 13
14
RT
A
A
B
C
D
E
F
B
C
D
E F
Vsense
Vsense
VREF
VREF
[12]
9
17
UCC28950 Block Diagram Employing “Green” Features 20% Accurate Adaptive ZVS Dead Band Over Wide Operating Range
Adaptive Timing MOSFET Rectifier Outputs
Programmable SR ON/OFF Control
Programmable Burst Mode at Very Light
or No Load
Programmable Slope Compensation
Peak Current or Voltage Mode Control
20-mA, 1.5% Accurate VREF Regulator
Closed Loop Soft Start with Enable
8% Accurate Switching Frequency Setting
Bi-directional Synchronization
3% Accurate Cycle-by-Cycle Current Limit
VDD Under Voltage Lockout
Thermal Shutdown
150 µA Start Up Current
Standard TSSOP-24 Package
Wide Temperature Range: -40 to 125 °C
8
10
4
13
2
1
12
GND
VREF
VDD
5V LDO
EN
UVLO Comp.
7.3V rise6.7V fall
VDD
VDD
RT
Cycle-by-Cycle Ilim
SS/EN
Thermal Shutdown
Is
OUTB
OUTA
LogicBlock
CLK
COMP
EA-
RSUM
4
8
10
OUTD
OUTC
VDD
ReferenceGenerator
8DELAB
8DELCD
Programmable Delay CD
Programmable Delay AB
PWM COMP
RAMP
4EA+
4CS
Ramp Summing4
Oscillator
8
10
OUTF
OUTE
8DELEF
Programmable Delay EF
8ADELEF
10ADEL
SYNC4
2 VLight Load Efficiency
Block
DCM TMIN
Soft Start & Enable with 0.55 V Thershold
Synchronization Block
ON/OFF
CS
CS
CS
CS
CS0.8V
2.8V
Lower “+” Input is Dominant
[12]
18
Digital Controller UCD3K – PSFB + Sync-Rec Configuration
10
19
Digital Controller C2000 – PSFB + Sync-Rec Configuration
Secondary SideController
Piccolo-A
Comp
ADC
PWM
Q11
Q1
Q2
Q8
Q7
Q13
Q14-Q15
Secondary SideController
Piccolo-A
Comp
ADC
PWM
Secondary SideController
Piccolo-A
Comp
ADC
PWM
Q11
Q1
Q2
Q8
Q7
Q13
Q14-Q15
20
MathCAD Program to Design Phase-Shifted Converter
Designer enters key spec requirements: Input/Output, Efficiency etc.
Program defines optimal ratio between switching and conduction losses
Program sets Rdson limits for primary and secondary FETs
Defines ZVS boundaries and suggests Ls and Lµ values to achieve ZVS
Calculates efficiency and power losses to compare with design goals
Provides power losses budget for further optimization if needed
Generates basic waveforms for voltages and currents through power stage components
What it does:
11
21
MathCAD Includes non-linear Coss Model to predict ZVSCoss 63pF Voss 100V
E Vds( )Coss
2.9Voss
2 lnVds 5 V
V
43 pF Vds
22
- analytical equation for Coss energy of IPB50R250CP
Analytical plot versus DS
0 50 100 150 200 250 300 350 400 450 5000
1
2
3
4
5
6
7
E Vds( )
J
Vds
Left plot shows that analytical equation based curve used in MathCAD follows the data sheet plot based on experimental data
22
SIMPLIS Model of Phase-Shifted Converter
Allows top level simulations of phase shifted full-bridge Dc-Dc converter
Provides behavioral model for most functions and features of UCC28950 controller
Simulates transitions between different operating modes: CCM, DCM, Burst Mode
Simulation time is relatively short: For example full soft start simulation takes 6 min to 10 min depending on power stage configuration
Provides small signal frequency response Bode plots
What it does:
12
23
SIMPLIS Model for Power Stage
Node A
OUTC
U8
RTN
VDD
U7
RTN
VDD
U6
RTN
VDD
U5
RTN
VDD
VDD
U4
RTN
OUTF
OUTE
DCM
DCM
S1
11.5
V2
OUTF
VQ3
C4
6.8n IC=0
R13
18.2k
Q7
FDP047AN08A0
Q8
FDP047AN08A0
Q2 Q1
12
V1
Vref
20p IC=0
C5
R37
10k
R38
40k
R35
50k
R24
360k
Vref
IQ4
IQ1
R4
23
0u
IIN
E2
208m
R47
2.2
R40
2.2
R36
2.2
C21
100p IC=0
R70
1K
R67
910
R64
39
C19
10n IC=0
R61
2k
R60
68k
C17
470p IC=0
C16
4.7n IC=0
R54
7.5k
R57
18.2k
Q6
STP20NM60FP
Q5
STP20NM60FP
Q4
STP20NM60FP
R9
4.7
C7
1u IC=0
C3
1u IC=0
R5
4.7
VprimaryTX3
R10
10k
R16
R1912
R2
12R12
R14
10k
R11
10k
OUTC
OUTA
R1
120
Vout
X1
1:50 F1
20m
L1
8.7u IC=0
R6
5m
R8
6m
4.15m IC=0
C1
L2
4.8u IC=0
380
V4R3
2m
R1712
R23
R26
R25
12
OUTC
OUTDOUTB
R7
10k
TX2
ILS
Q3
STP20NM60FP
C10
6.8n IC=0
Vref
R55
4.3kC18
10n IC=0
R63
2k
D1n4148
D1
R65
10kC20
470p IC=0
D1n4148
D2
R71
5.11k
R44
2.2
ILo
ILu
P1 S1
S2
TX4800u
L4
R1
5
37
.8m
R1
8
22
0u
IQ2
IQ3
VDD
R22
144k
R21
144k
R20
1.44
R27
1k
R30
10Meg
R34
10k
R33
1
R31
10Meg
U13-VIN
R29
1
1u IC=0
C2
VDD
300n IC=0
C6
CS
U1OUTAOUTB
DELABOUTC
DELCDOUTDDELEFOUTEOUTF
VDDGNDVREFSYNCRTADELDCMCSTMINRSUMADELEFSSENEAPEANCOMP
VQ4
OUTE
U2
DCM
U3
RTN
VDD
OUTA OUTBOUTD
Node B
[12]
24
Phase-Shifted Converter Design Example
• Input voltage: 300V to 400V
• Output voltage: 12V
• Output current: 55A
• Efficiency: up to 95.5%
• Includes bias supply and fan
• Size of DC/DC converter portion only: 10” x 2” x 1”
• Power Density 36W/cub. Inch
• Overall size: 15” x 2” x 1.6”
[3]
13
25
Phase-Shifted Converter Picture
Bias Supply FanPower Stage Control Card
DC/DC Converter Portion Size: 10” x 2” x 1”
26
Power Stage Schematic
14
27
Control Card Schematic
28
Measured Efficiency of 660W Phase-Shifted Converter Using UCC28950
0 5 10 15 20 25 30 35 40 45 50 5580
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Vin = 400V with LresVin = 350V with LresVin = 300V with Lres
Load current, A
Eff
icie
ncy,
%
Small difference between efficiencies at different input voltages indicate minimum switching losses of this design
Efficiency curve is flat over wide load current range because of light load power management technique
15
29
Summary
Power Saving and Efficiency Design Goals for Post-PFC Converter have been set based on Standards and Regulations
PSFB Converter efficiency enhancing technique over entire load current range has been discussed
Analog and Digital controllers capable to utilize optimal powersaving algorithm have been listed
MathCAD and SIMPLIS based design tools have been introduced and test results of prototype have been presented
30
Thanks and Any Questions?
16
31
ReferencesREFERENCES
1. Fasullo, G.; Kania, M. & Pitts, A. (2008). The Green revolution in DC power systems, Proceedings of 30th International Telecommunications Energy Conference, INTELEC’2008, pp. 1-7, ISBN: 978-1-4244-2056-8, San Diego, CA, USA, September 2008, IEEE
2. Mammano, R. (2006). Improving power supply efficiency - The global perspective, Texas Instruments Power Supply Design Seminar, Topic 1, SEM-1700, 2006
3. Rais Miftakhutdinov, “Power Saving Control Strategies and Their Implementation in DC/DC Converter for Data and Telecommunications Power Supply”, Proc. of IEEE Applied Power Electronics Conf., 2010, pp. 1897-1903.
4. Rais Miftakhutdinov, Zhenyu Yu, “New Controller Addresses Energy Saving in Server Power System”, Power Systems Design North America, January/February Issue, 2010, pp. 51-52.
5. Rais Miftakhutdinov, “Power Saving Solutions in DC/DC Converter for Data and Telecommunications Power System”, Proc. of PEDS-2009, Taipei, November 2009.
6. Rais Miftakhutdinov, “Energy Saving Drives New Approaches to Telecommunications Power System”, Chapter in the book “Telecommunications”, Intech, 2010
7. ENERGY STAR® program requirements for computer servers, version 1.0: http://www.energystar.gov/index.cfm?c=ent_servers.enterprise_servers
8. 80 PLUS Power Supplies Requirements: http://www.plugloadsolutions.com/80PlusPowerSupplies.aspx
9. Climate Savers Computing Initiative: http://www.climatesaverscomputing.org/
10. Texas Instruments, Datasheet: TMS320F28023 PiccoloTM microcontroller, http://focus.ti.com/docs/prod/folders/print/tms320f28023.html
11.Texas Instruments, Datasheet: UCD3020 Digital Power Controller, http://focus.ti.com/docs/prod/folders/print/ucd3020.html
12.Texas Instruments, Datasheet: Green Phase-Shifted Full-Bridge controller with synchronous rectification, UCC28950, http://focus.ti.com/docs/prod/folders/print/ucc28070.html