  • © Riley Power Inc., 2012 www.babcockpower.com

    Reducing NOx Emissions to Below 0.15 lb/106 Btu on a 600 MW Utility Boiler with

    Combustion Control Only

    by

    Craig A. PentersonManager, Fuel Equipment Design

    RILEY POWER INC.a Babcock Power Inc. company

    Kenneth R. Hules, Sc.D.Senior Principal Engineer, CFD

    RILEY POWER INC.a Babcock Power Inc. company

    Presented at DOE/EPRI/EPA/A&WMA Combined Power Plant

    Air Pollutant Control “Mega” SymposiumMay 19-22, 2003Washington, DC

    Technical Publ icat ion

    T-183

  • Text1: 0183

top related