rf solution rev1 20120321
Post on 26-Oct-2014
30 Views
Preview:
TRANSCRIPT
No RF Solution
Solution1
Solution2
Solution3
Solution4
Solution5
Solution6
2G 2G 3G
2G 2G&3G 2G&3G Combiner
2G/3G Combiner
2G2G&3G
2G&3G2G&3G 2G&3G Combiner
Solution 8
Solution 9
Solution 10
Solution 11
Solution 12
Solution7
2G 2G 3G
2G 2G&3G
2G&3G
+2G&3G Combiner
2G&3G
2G&3G
+2G&3G Combiner
3G
RF Antenna Type Combinner TypePer SectorRF Jumper
Length
N/A N/A 0
N/A 0
DX-1710-2170-65-18i-2F N/A <5M
CMA-B/6521/E0-6 or DX-1710-2170-65-18i-2F
DXX-1710-21701710-2170-6565-18i18i-MM N/A < 3 M
CMA-B/6521/E0-6
27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female
27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female
0 or 3M ( If Need
)
27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female
DX-1710-2170-65-18i-2F N/A 3 M
N/A
DXX-1710-21701710-2170-6565-18i18i-MM N/A
N/A
DXX-1710-21701710-2170-6565-18i18i-MMHBXX-6516DS-VTMCMA-BDHH_6521
MEGA Antenna :DX-1710-2170-65-19.5i-M
MEGA Combiner :Fingu Dual-Band Combiner 1920-2170MHZ 1710-1880MHZ
MEGA Antenna :DX-1710-2170-65-19.5i-M
MEGA Combiner :Fingu Dual-Band Combiner 1920-2170MHZ 1710-1880MHZ
MEGA Antenna :DX-1710-2170-65-19.5i-M
Per Sector Per SectorScenarioRF Jumper Node B Jumper
Qty Length Qty
0 2 or 4 For IBC Site Existing Combiner port enough
0 2 or 4 For IBC Site Existing Combiner port not enough
2 or 4 3 M 2 For Macro
2 For Macro
3 M 2 For Macro
2 For Macro
< 5 M > 5 M RNP
Make Decision
< 5 M > 5 M RNP
Make Decision
Tower RC Enough, but 2G&3G antenna should install in the same height
0 or 2 ( If Need )
< 5 M > 5 M RNP
Make Decision
Tower RC Not Enough, No Space For Add New Feeder
2 or 4 (If we Have to Swap 2G Jumper)
Tower RC Not Enough, Have Space For Add New Feeder
< 5 M > 5 M RNP
Make Decision
No Space For Add New Feeder, Existing antenna already support 2G and 3G dual band
2 3 M 2 For Macro
For Macro
For Macro New Site/Additional Sector 2G&3G
For Macro New Site/Additional Sector 2G&3G
For Macro
For Macro Additional Sector 3G (no 2G)
Tower RC Enough,and 2G&3G antenna can install in different height
Existing 2G Antenna has 4 port and supports dual band
New Site/Additional Sector 2G&3G (with RRU Solution)
Solution Description
No Need Add Combiner
Add Combiner
Replace 2 G Antenna to 4 Port Antenna
Use existing 2 Port 3G Antenna + Combiner
Add 2 Port 3G Antenna + Special Mounting Pole, Move 2G Antenna to Special Mounting Pole
Replace 2 G Antenna to Dual Band Antenna + Combiner
Using existing 4 port 2G&3G Antenna
Add 2 port 2G&3G Antenna + Combiner
Add 4 port 2G&3G Antenna
Add 2 port 2G&3G Antenna + Combiner
Add 2 port 3G Antenna
Add 2 Port 3G Antenna + Normal Mounting Pole, No need to touch 2G Antenna
RNP Description
Add Antenna 3G 2-port, with adding mounting which have same level with existing 2G antenna è Antenna 3G proposed 2-port & No combiner proposed.
Replace with Antenna 2G/3G 2-port and combiner (without feeder) è Antenna 3G proposed 2-port, With combiner proposed & Antenna 3G proposed different with Antenna 2G existing.
Replace antenna 2G existing with antenna 2G/3G 4-port. è Antenna 3G proposed 4-port
Without replace anything, just add combiner è Antenna 3G proposed 2-port (same with 2G existing), With combiner proposed & Antenna 3G proposed same with Antenna 2G existing
Add Feeder for 3G
Install Dual Band 2 port Antenna, Combiner, and Feeder
Install Dual Band 4 port Antenna and Feeder
Install RRU, Dual Band 2 port Antenna, and Combiner
Install 2 port 3G Antenna and Feeder
Add Antenna 3G 2-port, with normal mounting pole & No combiner proposed.
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page11of20
SN Code Information Name Type Option Description PIC Data Provided / Document
1 1.1 Phase Project Basic Data Batch1;Batch2;Batch3;Batch4 Work Package or Standalone PO PC
2 1.2 Zone Project Basic Data Zone1 (Java); Zone2 (Sumatra); Zone3 (KalSul) Zone Information PC
3 1.3 Region Project Basic Data Region Information PC
4 1.4 Town Project Basic Data get from planning & HCPT PC
5 1.5 CRLog Project Basic Data PC
6 1.6 LiveStatus Project Basic Data Active;Inactive;Propose Drop; PC
7 1.7 TX Cluster Project Basic Data get from Zhuchang PC
8 1.8 ProductID Project Basic Data get from site ID definition PC
9 1.9 TIServiceID Project Basic Data get from site ID definition PC
10 1.10 WPO Number Project Basic Data WPO Code or SPO Code The site under which WPO or SPO Code PC
Jabodetabek, West Java,Central Java, East Java, Bali Lombok, North Sumatera, Central Sumatera, South East Sumatera, South West Sumatera, West Kalimantan, Central Kalimantan, East Kalimantan, North Sulawesi, South Sulawesi
Original;Relocated;Original-Reactived;Relocated-Reactivated
Original: site/ link published in planning DB for the 1st timeOriginal-Reactived:the original site reactivatedRelocated: site/link relocate and change to another site IDRelocated-Reactivated:the relocated site reactivated
Propose Drop: not yet get CR, CR in processInactive: CR received
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page12of20
SN Code Information Name Type Option Description PIC Data Provided / Document
1 2.1TKServiceID
PC
2 2.2 LocationType Green Field, Roof Top, In-Building Green field or Rooftop or In-building PC
3 2.3IBCType
Non-IBC;IBC-Self Build;IBC-Sharing;IBC-Multi Operator PC
4 2.4 SAM ID SAM ID from planning only the number PC
5 2.5 NE Longitude (°) Get information from planning PC/RNP
6 2.6 NE Latitude (°) Get information from planning PC/RNP
7 2.7 FE Longitude (°) Get information from planning PC/RNP
8 2.8 FE Latitude (°) Get information from planning PC/RNP
9 2.9
10 2.10
Self Build;TowerCo Sharing;Operator Sharing;B2S;OSP;MiniCME;Non-TK
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page13of20
SN Code Information Name Type Option Description Data Provided / Document
1 lock uplink site code 0-Short Text
2 lock uplink site name 0-Short Text
3 lock link id 0-Short Text eg: 100001_100002
4 lock Link Capacity 0-Short Text
5 lock Site 1 Azimuth 0-Short Text NE site
6 lock Site 2 Azimuth 0-Short Text uplind link site, FE site
7 lock Site 1 Antenna diameter 0-Short Text
8 lock Site 2 Antenna diameter 0-Short Text
9 lock Site 1 Antenna height 0-Short Text
10 lock Site 2 Antenna height 0-Short Text
11 3.1 NE Site Tower Provider 5-Serial
12 3.2 NE Site Tower Height 3-Number Uplink FE Site Tower Height, unit: meter
13 3.3 Uplink FE Site Tower Provider 5-Serial
14 3.4 Uplink FE Site Tower Height 3-Number Uplink FE Site Tower Height, unit: meter
15 3.5 NE Site TX Priority 5-Serial Priority 1;Priority 2;Priority 3
16 3.6 NE Site TX Weight 3-Number
17 3.7 FE Site TX Priority 5-Serial Priority 1;Priority 2;Priority 3
18 3.8 FE Site TX Weight 3-Number
19 3.9 Uplink Sites Chain 1-Long Text
20 3.10 TNP Remark 1-Long Text
HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others
HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others
How many hops to on air site or BSC site, priority 1 = 1 hop, priority 2 = 2 hops, priority 3 = equal or more than 3 hops
the Site Weight equal to how many downlink sites (direct and indirect) including this site self
How many hops to on air site or BSC site, priority 1 = 1 hop, priority 2 = 2 hops, priority 3 = equal or more than 3 hops
the Site Weight equal to how many downlink sites (direct and indirect) including this site self
Please describe the uplink sites chain from RNC/BSC to this site. eg: RNC-Site ID1-Site ID2-Site ID3-This Site
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page14of20
SN Code Information Name Type Option Description Data Provided / Document
1 4.1 CR No 0-Short Text
2 4.2 SAM ID 1-Short Text
3 4.3 SAM Diameter 3-Number
4 4.4 Nominal Longitude (°) 0-Short Text
5 4.5 Nominal Latitude (°) 0-Short Text
6 4.6 Final Longitude (°) 0-Short Text eg: 115.239889
7 4.7 Final Latitude (°) 0-Short Text eg: -8.657111
8 4.8 Co-site Type 5-Serial 2G Only;3G Only;2G and 3G;Microwave Only
9 4.9 NodeB Type 5-Serial Indoor; Outdoor
10 4.10 Building Height (m) 3-Number
11 4.11 3G Antenna Type-A 0-Short Text
12 4.12 3G Antenna Type-B 0-Short Text
13 4.13 3G Antenna Type-C 0-Short Text
14 4.14 3G Mechanical Downtilt-A (°) 3-Number
15 4.15 3G Mechanical Downtilt-B (°) 3-Number
16 4.16 3G Mechanical Downtilt-C (°) 3-Number
17 4.17 3G Antenna Azimuth-A (°) 3-Number
18 4.18 3G Antenna Azimuth-B (°) 3-Number
19 4.19 3G Antenna Azimuth-C (°) 3-Number
20 4.20 3G Antenna Height-A (m) 3-Number
21 4.21 3G Antenna Height-B (m) 3-Number
22 4.22 3G Antenna Height-C (m) 3-Number
23 4.23 2G Equipment Vendor 0-Short Text Huawei,ZTE,NSN
24 4.24 3G NodeB Model 0-Short Text eg: Huawei BTS 3900
25 4.25 3G NodeB Config 0-Short Text eg: S111
26 4.26 3G RNC Name 0-Short Text
27 4.27 3G RNC ID 0-Short Text
28 4.28 3G Cluster ID 0-Short Text
29 4.29 3G Cell ID-A 0-Short Text
30 4.30 3G Cell ID-B 0-Short Text
31 4.31 3G Cell ID-C 0-Short Text
32 4.32 3G RF Solution-Sector A 0-Short Text
33 4.33 3G RF Solution-Sector B 0-Short Text
34 4.34 3G RF Solution-Sector C 0-Short Text
35 4.35 3G Frequency Band (MHz) 5-Serial 850 MHz;2100 MHz;
36 4.36 3G RNP Remark 1-Long Text
The height of antenna including the building height for rooftop siteThe height of antenna including the building height for rooftop siteThe height of antenna including the building height for rooftop site
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page15of20
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page16of20
SN Code Information Name Type Option Description Data Provided / Document
1 5.1 CR No 0-Short Text
2 5.2 SAM ID 1-Short Text
3 5.3 SAM Diameter 3-Number
4 5.4 Nominal Longitude (°) 0-Short Text
5 5.5 Nominal Latitude (°) 0-Short Text
6 5.6 Final Longitude (°) 0-Short Text eg: 115.239889
7 5.7 Final Latitude (°) 0-Short Text eg: -8.657111
8 5.8 Co-site Type 5-Serial 2G Only;3G Only;2G and 3G;Microwave Only
9 5.9 BTS or NodeB Type 5-Serial Indoor; Outdoor
10 5.10 Building Height (m) 3-Number
11 5.11 2G Antenna Type-A 0-Short Text
12 5.12 2G Antenna Type-B 0-Short Text
13 5.13 2G Antenna Type-C 0-Short Text
14 5.14 2G Mechanical Downtilt-A (°) 3-Number
15 5.15 2G Mechanical Downtilt-B (°) 3-Number
16 5.16 2G Mechanical Downtilt-C (°) 3-Number
17 5.17 2G Antenna Azimuth-A (°) 3-Number
18 5.18 2G Antenna Azimuth-B (°) 3-Number
19 5.19 2G Antenna Azimuth-C (°) 3-Number
20 5.20 2G Antenna Height-A (m) 3-Number Unit: Meter
21 5.21 2G Antenna Height-B (m) 3-Number
22 5.22 2G Antenna Height-C (m) 3-Number
23 5.23 2G Equipment Vendor 0-Short Text Huawei,ZTE,NSN
24 5.24 2G BTS Model 0-Short Text eg: NSN BS 241
25 5.25 2G BTS Config 0-Short Text eg: S222
26 5.26 2G BSC Name 0-Short Text
27 5.27 2G BSC ID 0-Short Text
28 5.28 2G Cluster ID 0-Short Text
29 5.29 2G Cell ID-A 0-Short Text
30 5.30 2G Cell ID-B 0-Short Text
31 5.31 2G Cell ID-C 0-Short Text
32 5.32 2G RF Solution-Sector A 0-Short Text
33 5.33 2G RF Solution-Sector B 0-Short Text
34 5.34 2G RF Solution-Sector C 0-Short Text
35 5.35 2G Frequency Band (MHz) 5-Serial 900 MHz;1800 MHz
61 5.36 2G RNP Remark 1-Long Text
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page17of20
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page18of20
SN Code Information Name Type Option Description Data Provided / Document
1 6.1 Determinated SAAF Ref No. 0-Short Text
2 6.2 Candidate Site SN for SAAF 5-Serial Site Candidate Sequence Number for Determinated SAAF
3 6.3 Transmission Category 5-Serial BTS Site;Hub Site;Transmission Site Only
4 6.4 Site Land Space Size (L*W) (m) 0-Short Text Unit: Meter, eg: 30m * 20m
5 6.5 Building Height (m) 3-Number
6 6.6 Type of Transaction 5-Serial Operator Sharing;TowerCo Sharing;Lease;Purchase;HCPT Own;Others Lease (Direct Lease); Sharing ('indirect' lease); Sale&Purchase
7 6.7 Tower Provider 5-Serial
8 6.8 Tower Sharing Type 5-Serial Built to Suit (B2S);Collocation;Tower Transfer Site
9 6.9 Type of Site Ownership 5-Serial Direct Owner;Hibah/Inheritance;Company;Government;Military;Others
10 6.10 Type of Access Road Ownership 5-Serial Direct Owner;Hibah/Inheritance;Company;Government;Military;Others
11 6.11 Type of Lessor 5-Serial Natural Person;Private Entity;Other Entity
12 6.12 Type of Object 5-Serial Hak Milik;Girik;HGB;Strata Title;Hak Pkai;Others
13 6.13 Lease Duration (Year) 3-Number
14 6.14 Lease Price Net (IDR, per year) 0-Short Text Lease Price Net (IDR, per year), Including PPh
15 6.15 BAK Ref No. 0-Short Text
16 6.16 PKS Ref No. 0-Short Text
17 6.17 Community Permit Status 5-Serial In Progress;Obtained
18 6.18 IMB Status 5-Serial
19 6.19 IMB Certificate No. 0-Short Text
20 6.20 Detailed Address 1-Long Text Please input the detailed address of the site
21 6.21 Address Alias 0-Short Text Please input the address alias or shortened form of the site address
22 6.22 Customer PIC 0-Short Text Please input the name of customer PIC for this site
23 6.23 Zip Code 0-Short Text
24 6.24 Province 0-Short Text
25 6.25 County or City 0-Short Text
26 6.26 Floor Number 0-Short Text Please input which floor is the equipment located
27 6.27 Owner Name 0-Short Text
28 6.28 Owner Phone Number 0-Short Text
29 6.29 Owner Email 0-Short Text
30 6.30 Contact Person 0-Short Text
31 6.31 Contact Person Phone Number 0-Short Text
32 6.32 Contact Person Email 0-Short Text
33 6.33 Special Entrance Permit 4-Yes Or No
34 6.34 Access Hour 7*24 4-Yes Or No
35 6.35 Site Location Type 5-Serial Please indicate the site location type for the convenience of site access.
36 6.36 SITAC Remark 1-Long Text
Q;Candidate R;Candidate S;Candidate T;Candidate U;Candidate V;Candidate W;Candidate X;Candidate Y;Candidate Z;
HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others
Built to Suit (B2S)-Dedicated for HCPT;Collocation-Share with the other operator;Tower Transfer Site-Tower usage transfer from TV, PLN, etc.
Private Property owned by Natural Person; Private Property owned by Private Entity; Inheritance (including granted property); Land/Building owned by Government (including military)
Private Property owned by Natural Person; Private Property owned by Private Entity; Inheritance (including granted property); Land/Building owned by Government (including military)
Natural Person (Perseorangan); Private Entity (Badan - Swasta); Other Entity, i.e Military, other government institution (Badan Lain)
Non Certificate Land (Tanah belum bersertifikat/Tanah Girik); Certificate with Freehold Title (Hak Milik); Certificate with Leasehold Title (HGB); Certificate with Right to Use Title (Hak Pakai)
Application submitted to Pemda;"Review in Progress" by Pemda;IMB Obtained
Should we need special entrance permit for access this site, if needed, please describe the detail information in the SA remark field.
Can this site be accessed in 7 days and 24 hours? If can't, please indicate the available access time in the SA remark field.
Green Field;Private House;Government;Company;School;Hospital;Appartment;Military;Others
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page19of20
document.xlsx Security Level:
04/07/2023 HUAWEI Confidential Page20of20
SN Code Information Name Type Option Description Data Provided / Document
1 7.1 Pole or Tower Type 5-Serial Mini tower for rooftop site, SST (Self support tower) for greenfield site.
2 7.2 Pole or Tower Height (m) 3-Number
3 7.3 Tower Legs Qty 3-Number
4 7.4 Pole or Tower Qty. 3-Number Unit: pcs
5 7.5 Tower Foundation Type 5-Serial
6 7.6 Diameter of Pile Found. (m) 3-Number
7 7.7 Length of Pile Found. (m) 3-Number
8 7.8 Tower Foundation Volume (m3) 0-Short Text Tower Foundation Volume (Foundation Space*H)(m3)
9 7.9 Shelter Type 5-Serial Big;Middle;Small;No Shelter
10 7.10 Shelter Size (L*W*H, m) 0-Short Text eg: L 6m*W 4m*H 2.7m
11 7.11 Fence Type 5-Serial Steel;Brick;Wooden;Others
12 7.12 Fence Length (m) 0-Short Text
13 7.13 Tower Pad Dimensions (L*W) 0-Short Text Tower Pad Dimensions (L*W)(Meter), eg: L 2m*W 2m
14 7.14 Access Road Dimensions (L*W) 0-Short Text Access Road Dimensions (L*W)(Meter), eg: L 15m*W 1m
15 7.15 0-Short Text
16 7.16 Equip or Shelter Pad Height (cm) 3-Number Unit: cm
17 7.17 Genset Pad Dimensions (L*W) 0-Short Text
18 7.18 Genset Pad Height (cm) 3-Number Unit: cm
19 7.19 Electricity Requirements (KVA) 3-Number
20 7.20 Power Supply by 5-Serial Building Facilities;PLN;PLN (New Trafo);Generator Set;Others
21 7.21 PLN Available or Not 4-Yes Or No
22 7.22 PLN Capacity (KVA) 3-Number
23 7.23 PLN Type 5-Serial Multiguna;KWH Meter(Permanent);Temporary;Others
24 7.24 PLN ID 0-Short Text
25 7.25 Need Genset or Not 4-Yes Or No
26 7.26 Genset Capacity (KVA) 3-Number
27 7.27 Air Condition Capacity (KVA) 3-Number
28 7.28 Quantity of Air Condition 3-Number Unit: Set
29 7.29 Air Warning Light 4-Yes Or No
30 7.30 CME Remark 1-Long Text
Pole;Monopole;Mini Tower;Wallmounting;SST-Light, SST-Medium, SST-Heavy, SST-Super Heavy;Others
Raft Foundation;Single Foundation;Pile Foundation;Steel Frame Foundation;Others
Equip or Shelter Pad Dimensions (L*W)
Equipment/Shelter Pad Dimensions (L*W)(Meter), Please indicate the Length and Width using unit meter. eg: L 2m*W 1m
Genset Pad Dimensions (L*W)(Meter), Please indicate the Length and Width using unit meter. eg: L 3m*W 2m
top related