Senergy® Cement-BoardStuccoTM Systems 1021100
TYPICAL DETAILS
1. Cement-Board Stucco 1000System Design Application(Plan View)
2. Cement-Board Stucco 1000System Design Application(Isometric View)
3. Cement-Board Stucco 500System Design Application(Plan View)
4. Cement-Board Stucco 500System Design Application(Isometric View)
5. Clad Window Jamb (Plan View)
6. Clad Window Head
7. Clad Window Sill
8. Primed Window Head
9. Primed Window Jamb (Plan View)
10. Horizontal Expansion Joint atFloorline Wood FrameConstruction
11. Control Joint— Reveal 1
12. Control Joint— Reveal 2
13. Control Joint— Reveal 3
14. Termination at Soffit / Gable End
15. Downspout Application(Plan View)
16. Pipe Penetration
17. Light Fixture
18. Dryer Vent
19. Termination at Foundation
20. Termination at Top of Deck
21. Termination at Bottom of Deck
22. Metal Coping Detail
23. EPS Shape Application
24. Corner Detail (Plan View)
25. Fascia / Soffit
26. Kick-out Flashing
11/07
Senergy® Cement-Board StuccoTM System
CBS-01 TYPICAL CEMENT-BOARD STUCCO 1000 SYSTEM DESIGNCBS-01 APPLICATION (PLAN VIEW)
CBS-02 TYPICAL CEMENT-BOARD STUCCO 1000 SYSTEM DESIGNCBS-02 APPLICATION (ISOMETRIC VIEW)
CEMENT BOARD
FRAMING
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SELF-ADHERING MESH TAPE (4" )
FRAMING
SENERGY REINFORCING MESH
CORROSION RESISTANTFASTENERS
SENERGY FINISH COAT
SENERGY BASE COAT
ACCEPTABLE SHEATHING
CEMENT BOARD
ACCEPTABLE SHEATHING
FLASHING OR STARTER TRACK
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY BASE COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
CBS-03 TYPICAL CEMENT-BOARD STUCCO 500 SYSTEM DESIGNCBS-03 APPLICATION (PLAN VIEW)
CBS-04 TYPICAL CEMENT-BOARD STUCCO 500 SYSTEMCBS-03 APPLICATION (ISOMETRIC VIEW)
CEMENT BOARD
FRAMING
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SECONDARY MOISTUREPROTECTION BARRIER
SELF-ADHERING MESH TAPE (4" )
FRAMING
SENERGY REINFORCING MESH
CORROSION RESISTANTFASTENERS
SENERGY FINISH COAT
SENERGY BASE COAT
CEMENT BOARD
FLASHING OR STARTER TRACK
SECONDARY MOISTUREPROTECTION BARRIER
SENERGY BASE COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
Senergy® Cement-Board StuccoTM System
CBS-05 TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW)
CBS-06 TYPICAL CLAD WINDOW HEAD DETAIL
CLAD WINDOW
BOND BREAKER TAPEAND SEALANT
CASING BEAD
MIN. 13 mm (1/2")
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP
CLAD WINDOW
DRIP EDGE FLASHINGSET IN SEALANT
CASING BEAD WITH WEEPS
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
CBS-07 TYPICAL CLAD WINDOW SILL DETAIL
CBS-08 TYPICAL PRIMED WINDOW HEAD DETAIL
CLAD WINDOW
BOND BREAKER TAPEAND SEALANT
CASING BEAD
MIN. 13 mm (1/2")
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP
PRIMED WINDOW
DRIP EDGE FLASHING SETIN SEALANT
CASING BEAD WITH WEEPS
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
Senergy® Cement-Board StuccoTM System
CBS-10 TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINEWOOD FRAME CONSTRUCTION
BACKER ROD AND SEALANT
CASING BEAD
WIDTH BY DESIGN
CBS-09 TYPICAL PRIMED WINDOW JAMB (PLAN VIEW)
PRIMED WINDOW
SEALANT
45 DEGREE TRIM
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERSHIELD, SENERSHIELD-R,9" SENERFLASH OR SENERWRAP
FRAMING
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
9" SENERFLASH OR SENERWRAP
CASING BEAD
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
CBS-11 CONTROL JOINT—REVEAL 1
CBS-12 CONTROL JOINT—REVEAL 2
TRIM ACCESSORY
CEMENT BOARD
ACCEPTABLE SHEATHING
MIN. 6 mm (1/4")
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCTBULLETIN #1023352 FORPROPER TRIM ACCESSORYATTACHMENT
VARIES
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCTBULLETIN #1023352 FORPROPER TRIM ACCESSORYATTACHMENT
TRIM ACCESSORY
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
Senergy® Cement-Board StuccoTM System
CBS-13 CONTROL JOINT—REVEAL 3
13 mm (1/2")
CBS-14 TYPICAL TERMINATION AT SOFFIT/GABLE END
FRAMING
MIN. 50 mm (2")
ACCEPTABLE SHEATHING
BLOCKING
SOFFIT
TRIM
FRIEZE BOARD
CEMENT BOARD
SENERSHIELD, SENERSHIELD-R OR SECONDARYMOISTURE PROTECTION BARRIER
NOTE :REFER TO CEMENT-BOARDSTUCCO 500 & 1000 TRIMACCESSORIES PRODUCT BUL-LETIN #1023352 FOR PROPERTRIM ACCESSORY ATTACH-MENT
TRIM ACCESSORY
CEMENT BOARD
ACCEPTABLE SHEATHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SEALANT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
CBS-15 TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW)
ACCEPTABLE SHEATHING
DOWNSPOUT
SLEEVE
DOWNSPOUT STRAP
SEALANT
FASTENER SET IN SEALANT
SENERSHIELD, SENERSHIELD-R OR SECONDARYMOISTURE PROTECTION BARRIER
CBS-16 TYPICAL PIPE PENETRATION
ACCEPTABLE SHEATHING
FRAMING
SEALANT AT PERIMETEROF PENETRATION
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
CBS-18 TYPICAL DRYER VENT
DRYER VENT
FASTENER SET IN SEALANT
SET FLANGE IN SEALANT
SEALANT AT PERIMETER OFPENETRATION
ACCEPTABLE SHEATHING
FASTENER THROUGHNYLON SLEEVE
SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTIONBARRIER
11/07
Senergy® Cement-Board StuccoTM System
CBS-17 TYPICAL LIGHT FIXTURE
FRAMING
SET FLANGE IN SEALANT
SMALL LIGHT FIXTURE
ACCEPTABLE SHEATHING
CEMENT BOARD
SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
CBS-19 TYPICAL TERMINATION AT FOUNDATION
ACCEPTABLE SHEATHING
FRAMING
SEALANT
FLASHING
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
CBS-20 TYPICAL TERMINATION AT TOP OF DECK
FLASHING SET IN SEALANT
JOIST
SEALANT
DECK
FRAMING
ACCEPTABLE SHEATHING
MIN. 25 mm (1")
MIN. 50 mm (2")CEMENT BOARD
FLASHING
SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER
NOTE:TERMINATE SENERGY CEMENT-BOARD STUCCO SYSTEM 203 mm(8") MIN. ABOVE GRADE.
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
CASING BEAD WITH WEEPS
FOUNDATION
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
CASING BEAD WITH WEEPS
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
CBS-22 TYPICAL METAL COPING DETAIL
METAL COPING
FRAMING
ACCEPTABLE SHEATHING
50 mm (2")
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
SEALANT
11/07
Senergy® Cement-Board StuccoTM System
CBS-21 TYPICAL TERMINATION AT BOTTOM OF DECK
FLASHING
JOIST
SEALANT
ACCEPTABLE SHEATHING
50 mm (2")
CEMENT BOARD
FRAMING
SENERSHIELD, SENERSHIELD-R ORSECONDARY MOISTURE PROTECTION BARRIER
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
50 mm (2")
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING• MESH• SENERGY FINISH COAT
11/07
CBS-23 TYPICAL EPS SHAPE APPLICATION
FRAMING
ACCEPTABLE SHEATHING
SENERGY BASE COAT
EPS AESTHETIC BAND
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
CBS-24 TYPICAL CORNER DETAIL (PLAN VIEW)
FRAMING
2 LAYERS FLEXGUARD 4
ACCEPTABLE SHEATHING
SENERSHIELD,SENERSHIELD-R ORSECONDARY MOISTUREPROTECTION BARRIER
CEMENT BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
MIN. 6:12 SLOPE
CEMENT BOARD
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
11/07
Senergy® Cement-Board StuccoTM System
CBS-25 TYPICAL FASCIA / SOFFIT DETAIL
ACCEPTABLE SHEATHING
CEMENT-BOARD
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
CBS-26 TYPICAL KICK-OUT FLASHING DETAIL
NOTE:• KICK-OUT FLASHING MUST BE ANGLED100˚ MIN. TO ALLOW FOR PROPERDRAINAGE.
• KICK-OUT FLASHING SEAMS MUST BESOLDERED OR SEALED WITHAPPROPRIATE SEALANT.
• TERMINATE SENERGY CEMENT-BOARDSTUCCO 1000 SYSTEM 50 MM (2") MIN.ABOVE ROOF.
STEP FLASHING
BACKER ROD AND SEALANT
ROOF SHINGLES
BUILDING PAPER
DRIP EDGE
KICK-OUT FLASHING
MIN. 100 mm (4")
MIN. 50 mm (2")
ACCEPTABLE SHEATHING
CEMENT-BOARD STUCCO SYSTEM
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
SENERSHIELD, SENERSHIELD-ROR SECONDARY MOISTUREPROTECTION BARRIER
CEMENT BOARDCASING BEAD
DRAINAGE TRIM ACCESSORY
SENERGY LAMINA:• SENERGY BASE COAT• SENERGY REINFORCING MESH• SENERGY FINISH COAT
FRAMING, ACCEPTABLE SHEATHINGAND SEALANT BY OTHERS
NOTE:
General NotesBASF Wall Systems is an operating unit ofBASF Construction Chemicals, LLC. (hereinafter referred to as “BASF Wall Systems”Thesedetails are presented in good faith by BASFWall Systems and represent typical and/orgeneral conditions. They are offered as a guidefor consideration to assist the designer, specifier,installer and/or owner. The responsibility remainswith the user for the design of any system.For conditions not shown, consult BASFWallSystems for specific recommendations. Consultcurrent Senergy technical bulletins for suchinformation as acceptable sealants, insulationattachment methods, installation of air/weatherbarriers, residential policy, code and testreports, geo-climatic considerations, etc.Installation requirements for sealant (jointsize configuration, primers, bond breakers)shall be in accordance with sealantmanufacturer’s specifications and instructions.
Technical SupportConsult the BASF Wall Systems TechnicalServices Department for specific recommendationsconcerning all other applications. Consult theSenergy website, www.senergy.basf.com, foradditional information about products andsystems and for updated literature.
Residential PolicyOn one and two-family residential framedconstruction, BASF Wall Systems requiresthat the wall system selected be one thatincludes provisions for water drainage.The choices include Senturion® line ofwater drainage EIFS, commercial Senerflex®Channeled Adhesive or Channeled InsulationDesign, Senergy Stucco Wall System, andSenergy Cement-Board StuccoTM Systems.There are no exceptions to this policy. Underno circumstances will BASF Wall Systemswarrant the use of any other system onthis type of construction without expressedwritten authorization from BASF WallSystems [Residential construction usingEIFS on masonry (CMU) or poured concretedoes not require the additional water drainageprovisions described above. Senergy ExteriorSurfacing Systems for insulating concreteforms are also acceptable.] See the SenergyResidential Policy Bulletin for a more detaileddiscussion of this topic. Consult BASF WallSystems Technical Services Department forspecific recommendations concerning all otherapplications. Consult the Senergy website,www.senergy.basf.com for additional informationabout products and systems and for updatedliterature.
DisclaimerThis information and all further technicaladvice are based on BASF Wall Systems’present knowledge and experience. However,BASF assumes no liability for providing suchinformation and advice including the extentto which such information and advice mayrelate to existing third party intellectual propertyrights, especially patent rights. In particular,BASF Wall Systems disclaims any and allCONDITIONS AND WARRANTIES, WHETHEREXPRESS OR IMPLIED, INCLUDING THEIMPLIED WARRANTIES OF FITNESS FOR APARTICULAR PURPOSE OR MERCHANTABILITY.BASF WALL SYSTEMS SHALL NOT BERESPONSIBLE FOR CONSEQUENTIAL, INDIRECTOR INCIDENTAL DAMAGES (INCLUDING LOSSOF PROFITS) OF ANY KIND. BASF Wall Systemsreserves the right to make any changesaccording to technological progress or furtherdevelopments. It is the customer’s responsibilityand obligation to carefully inspect and test anyincoming goods. Performance of the product(s)described herein should be verified by testingand carried out only by qualified experts. It isthe sole responsibility of the customer to carryout and arrange for any such testing. Referenceto trade names used by other companies isneither a recommendation, nor an endorsementof any product and does not imply that similarproducts could not be used.
top related