senergy platinum ci stucco plus...typical details for a premium impact resistant cement plaster...

36
Senergy Platinum CI Stucco Plus Typical details for a premium impact resistant cement plaster stucco system featuring Neopor ® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Upload: others

Post on 12-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco PlusTypical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Page 2: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

(THIS PAGE INTENTIONALLY LEFT BLANK)

Page 3: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Typical details for a premium impact resistant cement plaster stucco system featuring

Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

Notes: • Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• The details within represent BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. They are presented in good faith by BASF Wall Systems. The details are subject to change without notice. BASF Wall Systems accepts no liability for the end use of the details. For conditions not shown, consult BASF Wall Systems for review of specific detail.

1. Typical Fastening Pattern

2. Typical Framed / Sheathed Construction

3. Typical Masonry / Concrete Construction

4. Typical Termination at Foundation - Flush with Casing / Stop Bead

5. Typical Termination at Foundation with Casing / Stop Bead

6. Typical Termination at Foundation with Amico C-I Weep Trac

7. Typical Change in Substrate

8. Typical Trim Junction

9. Typical Surface Control Joint

10. Typical Inside Corner Control Joint - Framed / Sheathed Construction

11. Typical EPS Shape Application

12. Typical Corner Bead

13. Typical Decorative Shape

14. Typical Window Head (Flush) 15. Typical Window Head (Recessed)

16. Typical Flanged Window Head 17. Typical Window Jamb (Flush) 18. Typical Window Jamb (Recessed)

19. Typical Flanged Window Jamb 20. Typical Window Sill (Flush) 21. Typical Window Sill (Recessed)

22. Typical Flanged Window Sill

23. Typical Pipe Penetration

24. Typical Dryer Vent

25. Typical Downspout

26. Typical Light Fixture

27. Typical Termination at Metal Coping / Roof Edge Flashing - Option 01

28. Typical Termination at Metal Coping / Roof Edge Flashing - Option 02

29. Typical Flashing / Termination at Roof

30. Typical Kick-Out Flashing

TABLE OF CONTENTS

Page 4: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

(THIS PAGE INTENTIONALLY LEFT BLANK)

Page 5: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

TYPICAL FASTENING PATTERN

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-01

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Sheathing: Fasten per sheathing manufacturer’s recommendations or project design requirements.

• Neopor GPS Plus Rigid Insulation Board: Secure with 2 to 3 fasteners per board to hold in place until lath is installed.

• Lath – PERMALATH 1000: use appropriate fasteners spaced not more than 152 mm (6”) o.c. vertically, 406 mm (16”) o.c. horizontally; metal or wire lath: use appropriate fasteners spaced not more than 178 mm (7”) o.c. vertically, 406 mm (16”) or 610 mm (24”) o.c. horizontally, per requirements of ASTM C1063. Refer to SENERGY PLATINUM CI STUCCO PLUS specifications.

Page 6: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-02

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB is dry prior to Neopor GPS Plus Rigid Insulation Board installation.

• Basic requirements for Plaster Base:

- BASF STUCCOBASE 3/8” to ½” thickness: Min. 1” 20 ga. wire, min. 2.5 lb/sq.yd. metal lath or acceptable alternative.

- BASF STUCCOBASE equal to or greater than ½” thickness: PERMALATH 1000 or min. 1½” 17 ga. wire, min. 2.5 lb/sq.yd. metal lath or acceptable alternative.

TYPICAL FRAMED/SHEATHED CONSTRUCTION

FRAMING*

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

Page 7: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-03

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Multiple coats of SENERSHIELD-R/-RS/-VB may be required to achieve a pin-hole free application.

• Ensure SENERSHIELD-R/-RS/-VB is dry prior to Neopor GPS Plus Rigid Insulation Board installation.

• Basic requirements for Plaster Base:

- BASF STUCCOBASE 3/8” to 1/2” thickness: Min. 1” 20 ga. wire, min. 2.5 lb/sq.yd. metal lath or acceptable alternative.

- BASF STUCCOBASE equal to or greater than 1/2” thickness: PERMALATH 1000 or min. 1½ ” 17 ga. wire, min. 2.5 lb/sq.yd. metal lath or acceptable alternative.

TYPICAL MASONRY/CONCRETE CONSTRUCTION

MASONRY/CONCRETE*

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

Page 8: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-04

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Terminate the PLATINUM CI STUCCO PLUS system a minimum of 152 mm (6”) above raw earth and 50 mm (2”) above paved surface.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the casing/stop bead flange.

• Ensure casing/stop bead includes weep holes to facilitate drainage.

TYPICAL TERMINATION AT FOUNDATION -FLUSH WITH CASING / STOP BEAD

FRAMING*

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

FLASHING

CASING / STOP BEAD WITH WEEP HOLES

SEALANT*

FOUNDATION*

Page 9: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-05

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Terminate the PLATINUM CI STUCCO PLUS system a minimum of 152 mm (6”) above raw earth and 50 mm (2”) above paved surface.

• Provide minimum 25 mm (1”) overlap at framing/foundation transition.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the casing/stop bead flange.

• Ensure casing/stop bead includes weep holes to facilitate drainage.

TYPICAL TERMINATION AT FOUNDATION WITH CASING / STOP BEAD

FRAMING*

ACCEPTABLE SHEATHING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERGY FINISH

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

SENERSHIELD-R/-RS/-VB

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

SEALANT*

CASING / STOP BEAD W/ WEEP HOLES

FOUNDATION*

Page 10: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-06

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Terminate the PLATINUM CI STUCCO PLUS system a minimum of 152 mm (6”) above raw earth and 50 mm (2”) above paved surface.

• Provide minimum 25 mm (1”) overlap at framing/foundation transition.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

TYPICAL TERMINATION AT FOUNDATION WITH AMICO C-I WEEP TRACTM

FRAMING*

ACCEPTABLE SHEATHING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

CORNER BEAD

AMICO C-I WEEP TRACTM

FOUNDATION*

Page 11: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-07

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB application is continuous behind the PLATINUM CI STUCCO PLUS system at change in substrate – apply BASF WS FLASH with FLASHING PRIMER at change in substrate followed by fully coating WS FLASH with SENERSHIELD-R/-RS/-VB.

• Do not apply finish into joint to receive sealant.

TYPICAL CHANGE IN SUBSTRATE

CONCRETE/MASONRY*

FRAMING*

BACKER ROD AND SEALANT*

CASING / STOP BEAD

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

Page 12: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-08

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• At trim intersection it is recommended that the vertical trim be continuous.

TYPICAL TRIM JUNCTION

3 MM (1/8”) GAP OR AS RECOMMENDED BY TRIM MANUFACTURER

ACCEPTABLE SEALANT

NYLON ANCHOR OR WIRE TIE TO PERMALATH 1000 OR METAL PLASTER BASE

MITER TRIM AS SHOWN

VERTICAL TRIM TO BE CONTINUOUS

ACCEPTABLE SEALANT

NYLON ANCHOR OR WIRE TIE TO PERMALATH 1000 OR METAL PLASTER BASE

3 MM (1/8”) GAP OR AS RECOMMENDED BY TRIM MANUFACTURER

Page 13: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-09

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Provide control joints every 13m2 (144 ft2) and placement as determined by the Design Professional. Maximum recommended uncontrolled length or width is 5.5 m (18 ft) and a maximum uncontrolled length to width ratio of 2-1/2 to 1.

• Lath must be broken at the control joint accessory.

TYPICAL SURFACE CONTROL JOINT

FRAMING*

ACCEPTABLE SHEATHING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

NYLON ANCHOR OR WIRE TIE

SURFACE CONTROL JOINT

Page 14: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-10

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB application is continuous behind the PLATINUM CI STUCCO PLUS system – embed BASF MAXFLASH Liquid Flashing Membrane or BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB at inside corner.

TYPICAL INSIDE CORNER CONTROL JOINT-FRAMED / SHEATHED CONSTRUCTION

FRAMING*

CORNER CONTROL JOINT

ACCEPTABLE SHEATHING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

Page 15: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-11

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Extend BASF DIAMONDSHIELD or Senergy Reinforcing Mesh and Base Coat from band or shape onto BASF STUCCOBASE a minimum of 76 mm (3”).

• Provide a 6:12 slope on horizontal applications greater than 1”.

• Adhere EPS or NEOPOR GPS PLUS Rigid Insulation band/shape with Senergy Base Coat to BASF STUCCOBASE surface.

TYPICAL EPS OR NEOPOR GPS PLUS SHAPE APPLICATION

FRAMING*

ACCEPTABLE SHEATHING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERSHIELD-R/-RS/-VB

EPS OR NEOPOR GPS PLUS RIGID INSULATION BOARD

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

SENERGY BASE COAT

Page 16: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-12

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Attach corner bead with wire ties, anchors or fasteners to resist movement during application of BASF STUCCOBASE.

• Fill corner bead solid with BASF STUCCOBASE.

TYPICAL CORNER BEAD

FRAMING*

ACCEPTABLE SHEATHING*

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD PERMALATH 1000 OR METAL PLASTER BASE

NYLON ANCHOR OR WIRE TIE

CORNER BEAD

BASF STUCCOBASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SENERGY FINISH

Page 17: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-13

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Extend BASF DIAMONDSHIELD or Senergy Reinforcing Mesh and Base Coat from band or shape onto BASF STUCCOBASE a minimum of 76 mm (3”).

• Adhere EPS or NEOPOR GPS PLUS Rigid Insulation band/shape with Senergy Base Coat to BASF STUCCOBASE surface.

TYPICAL DECORATIVE SHAPE

FRAMING*

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

SENERGY ADHESIVE / BASE COAT FOR DECORATIVE SHAPE

BASF STUCCOBASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

EPS OR NEOPOR GPS PLUS RIGID INSULATION BOARD DECORATIVE SHAPE

SENERGY FINISH

Page 18: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-14

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

• Provide end-dams at flashing terminations.

• Seal flashing drip edge to window frame.

TYPICAL WINDOW HEAD (FLUSH)

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

CORNER BEAD

WINDOW HEAD FLASHING*

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

BACKER ROD AND SEALANT*

AMICO C-I WEEP TRACTM

WINDOW*

Page 19: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

TYPICAL WINDOW HEAD (RECESSED)

170315-15

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY FINISH

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

CORNER BEAD

AMICO C-I WEEP TRACTM

BACKER ROD AND SEALANT*

WINDOW*

Page 20: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-16

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• As recommended by window manufacturer, apply sealant to back of window flange at head prior to installation of window.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

• Provide end-dams at flashing terminations.

• Seal flashing drip edge to window frame.

TYPICAL FLANGED WINDOW HEAD

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

SENERGY FINISH

FRAMING*

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

CORNER BEAD

WINDOW HEAD FLASHING*

BACKER ROD AND SEALANT*

AMICO C-I WEEP TRACTM

WINDOW*

Page 21: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-17

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB and BASF MAXFLASH Liquid Flashing Membrane and BASF SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• Do not apply finish into joint to receive sealant.

• Use non-hole punched version of Amico C-I Weep Trac on jambs.

TYPICAL WINDOW JAMB (FLUSH)

FRAMING*

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

AMICO C-I WEEP TRACT

BASF STUCCOBASE

CORNER BEAD

PERMALATH 1000 OR METAL PLASTER BASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

BACKER ROD AND SEALANT*

SENERGY FINISH

WINDOW*

Page 22: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB and BASF MAXFLASH Liquid Flashing Membrane and BASF SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• Use non-hole punched version of Amico C-I Weep Trac on jambs.

TYPICAL WINDOW JAMB (RECESSED)

170315-18

FRAMING*

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

BACKER ROD AND SEALANT*

AMICO C-I WEEP TRACTM

CORNER BEAD

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SENERGY FINISH

WINDOW*

Page 23: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

TYPICAL FLANGED WINDOW JAMB

170315-19

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB and BASF MAXFLASH Liquid Flashing Membrane and BASF SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• As recommended by window manufacturer, apply sealant to back of window flange at jamb prior to installation of window.

• Use non-hole punched version of Amico C-I Weep Trac on jambs.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over Amico C-I Weep Trac.

FRAMING*

ACCEPTABLE SHEATHING*

BASF MAXFLASH OR BASF SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R/-RS/-VB

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

AMICO C-I WEEP TRACTM

BASF STUCCOBASE

CORNER BEAD

PERMALATH 1000 OR METAL PLASTER BASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

BACKER ROD AND SEALANT*

SENERGY FINISH

WINDOW*

Page 24: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB, BASF MAXFLASH Liquid Flashing Membrane and BASF SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• Do not apply finish into joint to receive sealant.

• Use non-hole punched version of Amico C-I Weep Trac on sill.

170315-20

TYPICAL WINDOW SILL (FLUSH)

FRAMING*

WINDOW*

AMICO C-I WEEP TRACTM

BACKER ROD AND SEALANT*

CORNER BEAD

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SENERGY FINISH

Page 25: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-21

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB and BASF MAXFLASH Liquid Flashing Membrane or SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• Use non-hole punched version of Amico C-I Weep Trac on sill.

TYPICAL WINDOW SILL (RECESSED)

FRAMING*

WINDOW*

WINDOW SILL FLASHING*

AMICO C-I WEEP TRACTM

CORNER BEAD

SEALANT*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SENERGY FINISH

Page 26: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-22

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure SENERSHIELD-R/-RS/-VB and BASF MAXFLASH Liquid Flashing Membrane or SHEATHING FABRIC are properly applied into rough opening in accordance with application guidelines. Reference Air/Water-Resistive/Vapor Barrier Application Guidelines technical bulletin.

• Do not seal window sill flange unless recommended by window manufacturer.

• Use non-hole punched version of Amico C-I Weep Trac on sill.

TYPICAL FLANGED WINDOW SILL

WINDOW*

BASF STUCCOBASE

CORNER BEAD

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

PERMALATH 1000 OR METAL PLASTER BASE

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

ACCEPTABLE SHEATHING*

Page 27: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-23

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• SENERSHIELD-R/-RS/-VB with BASF MAXFLASH Liquid Flashing Membrane or SHEATHING FABRIC or WS FLASH with FLASHING PRIMER can be applied from sheathing onto pipe in lieu of the secondary seal.

• Ensure all penetrations through the PLATINUM CI STUCCO PLUS system are properly sealed.

TYPICAL PIPE PENETRATION

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SECONDARY SEAL*

SEALANT*

PIPE*

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

SENERGY FINISH

Page 28: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

TYPICAL DRYER VENT• Install BASF materials in accordance

with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• SENERSHIELD-R/-RS/-VB with BASF MAXFLASH Liquid Flashing Membrane or SHEATHING FABRIC or WS FLASH with FLASHING PRIMER can be applied from sheathing onto pipe in lieu of the secondary seal.

• Ensure all fastener penetrations through the PLATINUM CI STUCCO PLUS system are properly sealed.

170315-24

ACCEPTABLE SHEATHING*

SENERSHIELD-R/-RS/-VB

NEOPOR GPS PLUS RIGID INSULATION BOARD

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

VENT SLEEVE*

DRYER VENT FLANGE SET IN SEALANT*

SEALANT AT PERIMETER OF SHEATHING PENETRATION*

DRYER VENT*

FASTENERS THROUGH SLEEVE*

FASTENERS SET IN SEALANT*

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

Page 29: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure all fastener penetrations through the PLATINUM CI STUCCO PLUS system are properly sealed.

TYPICAL DOWNSPOUT

170315-25

DOWNSPOUT*

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

SENERGY FINISH

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

NEOPOR GPS PLUS RIGID INSULATION BOARD

FASTENER W/ SLEEVE SET IN SEALANT*

DOWNSPOUT STRAP SET IN SEALANT*

ACCEPTABLE SHEATHING*

Page 30: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Ensure all penetrations through the PLATINUM CI STUCCO PLUS system are properly sealed.

TYPICAL LIGHT FIXTURE

170315-26

SENERSHIELD-R/-RS/-VB

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

SENERGY BASE COAT

PERMALATH 1000 OR METAL PLASTER BASE

BASF STUCCOBASE

LIGHT FIXTURE FLANGE SET IN SEALANT*

SENERGY FINISH

MOUNTING BOX WITH BLOCKING, AS NEEDED*

LIGHT FIXTURE*

NEOPOR GPS PLUS RIGID INSULATION BOARD

ACCEPTABLE SHEATHING*

Page 31: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-27

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• It is recommended to lap coping or roof edge flashing over the PLATINUM CI STUCCO PLUS system a minimum of 50 mm (2”) with drip edge sealed.

TYPICAL TERMINATION AT METAL COPING / ROOF EDGE FLASHING - OPTION 01

METAL COPING / ROOF EDGE FLASHING*

ROOFING MEMBRANE*

BLOCKING*

CLEAT*

FRAMING*

CASING / STOP BEAD*

SEALANT*

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

ACCEPTABLE SHEATHING*

Page 32: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

TYPICAL TERMINATION AT METAL COPING / ROOF EDGE FLASHING - OPTION 02

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• It is recommended to lap coping or roof edge flashing over the PLATINUM CI STUCCO PLUS system a minimum of 50 mm (2”) with drip edge sealed.

170315-28

METAL COPING / ROOF EDGE FLASHING*

ROOFING MEMBRANE*

BLOCKING*

CLEAT*

FRAMING*

CORNER BEAD*

SEALANT*

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

NEOPOR GPS PLUS RIGID INSULATION BOARD

SENERSHIELD-R/-RS/-VB

ACCEPTABLE SHEATHING*

Page 33: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed BASF SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

• Terminate PLATINUM CI STUCCO PLUS system a minimum of 50 mm (2”) above sloped roof.

TYPICAL FASTENING / TERMINATION AT ROOF

170315-29

SENERSHIELD-R/-RS/-VB

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

NEOPOR GPS PLUS RIGID INSULATION BOARD

PERMALATH 1000 OR METAL PLASTER BASE

SENERGY FINISH

BASF STUCCOBASE

AMICO C-I WEEP TRACTM AND CORNER BEAD OR CASING / STOP BEAD WITH WEEP HOLES

FLASHING*

ROOF SYSTEM*

Page 34: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

Senergy Platinum CI Stucco Plus

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com

(* NOTE: BY OTHERS)

This detail represents BASF Corporation - Wall Systems (hereinafter BASF Wall Systems) latest recommendations. It is presented in good faith by BASF Wall Systems. The detail is subject to change without notice. BASF Wall Systems accepts no liability for the end use of the detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. For the most current version of this literature, please visit our website at www.senergy.basf.com.

170315-30

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of BASF products.

• Use BASF MAXFLASH Liquid Flashing Membrane or embed SHEATHING FABRIC in SENERSHIELD-R/-RS/-VB where it laps over the Amico C-I Weep Trac flange.

• Terminate PLATINUM CI STUCCO PLUS system a minimum of 50 mm (2”) above sloped roof.

• Extend step flashing 50 mm (2”) behind PLATINUM CI STUCCO PLUS system.

• Kickout flashing: sealed or soldered seams, recommended minimum 100 mm (4”) in height, extend 50 mm (2”) from wall and angled to direct water into gutter/away from wall surface.

TYPICAL KICK-OUT FLASHING

SENERGY FINISH

SENERGY BASE COAT

BASF DIAMONDSHIELD OR SENERGY REINFORCING MESH (OPTIONAL)

BASF STUCCOBASE

PERMALATH 1000 OR METAL PLASTER BASE

NEOPOR GPS PLUS RIGID INSULATION BOARD

AMICO C-I WEEP TRACTM AND CORNER BEAD OR CASING / STOP BEAD WITH WEEP HOLES

STEP FLASHING*

SENERSHIELD-R/-RS/-VB

ACCEPTABLE SHEATHING*

SHINGLES*

SEALANT*

KICK-OUT FLASHING*

GUTTER*

Page 35: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

NOTES

Page 36: Senergy Platinum CI Stucco Plus...Typical details for a premium impact resistant cement plaster stucco system featuring Neopor® GPS Plus Rigid Insulation Board and SENERSHIELD-R/-RS/-VB

WarrantyBASF warrants this product to be free from manufacturing defects and to meet the technical properties on the current Product Bulletin, if used as directed within shelf life. Satisfactory results depend not only on quality products but also upon many factors beyond our control. BASF MAKES NO OTHER WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS PRODUCTS. The sole and exclusive remedy of Purchaser for any claim concerning this product, including but not limited to, claims alleging breach of warranty, negligence, strict liability or otherwise, is shipment to purchaser of product equal to the amount of product that fails to meet this warranty or refund of the original purchase price of product that fails to meet this warranty, at the sole option of BASF. In the absence of an extended warranty issued by BASF, any claims concerning this product must be received in writing within one (1) year from the date of shipment and any claims not presented within that period are waived by Purchaser. BASF WILL NOT BE RESPONSIBLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL (INCLUDING LOST PROFITS) OR PUNITIVE DAMAGES OF ANY KIND. Purchaser must determine the suitability of the products for the intended use and assumes all risks and liabilities in connection therewith. This information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights, nor shall any legal relationship be created by or arise from the provision of such information and advice. BASF reserves the right to make any changes according to technological progress or further developments. The Purchaser of the Product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with a full application of the product(s). Performance of the product described herein should be verified by testing and carried out by qualified experts.

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.senergy.basf.com© 2017 BASF Corporation rev 170315

For the most current version of this literature, please visit our website at www.senergy.basf.com.