tagore theater case study

Post on 14-Apr-2017

660 Views

Category:

Design

4 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Location

Location

Location

Location

V2 RoadV3 RoadApproach

To Sector 17

Sun path

South West

Winter Wind Direction

North East

Summer Wind Direction

Amenities(School)Commercial

Main SiteResidential

Open Spaces

Main EntranceService Entrance

Parking Area

Entrance for performers

Entrance forspectators

Backstage

Underground Rehearsal Hall

Typical Model

WoodGlass

ConcreteBlack Marble

Bricks

Exterior Materials

Concrete Tiles

MAIN ENTRANCEMAIN ENTRANCE IS A GLASS CHAMBER SUPPORTED WITH STEEL BEAMS COVEREDWITH WOODEN PLATES AND COLUMNS, IT HAS TWO MAIN ENTRANCES WITH 7’10” HEIGHT AND 6’2” WIDE THE AREA OF THE GLASS CHAMBER IS 900 SQ FT. APPROX, THE CHMABER IS ON BOTH SIDES OF THE AUDITORIUM BUT THE CHMABER TOWARDS THE MAIN ENTRANCE IS FUNCTIONAL.

INTERIORS

THE STRUCTURE OF THE CHAMBER IS FABRICATION.THE STRUCTURE ALLOWS THE NATURAL LIGHTNING

AND GIVES NATURALNESS AND PRESENTSCORBUSIER’S PHILOSPHY OF MATERIAL EXPOSURE.

TYPICAL PLAN

interiors

Spectator’s area Total seating area

801. No. of public

entrances 6. Private entrances

2.

Chair

Backstage

13’

Stage Entrance

Stage• Stage has an

area of 12mx15m.• The height of

the stage is 2’.• The angle of

view from center of stage is 90 degrees.• Wooden flooring

is used.• Distance

between stage and front row is 3’.

ceilingThe ceiling used for reducing reverberation time, it provides important performance attributes such as light reflectants, fire resistance and easy accessibility to building systems.

ceiling

SERVICESCHILLERA chiller is a machine that removes heat from a liquid via a vapor compression or absorption refrigeration cycle. This liquid can then be circulated through a heat exchanger to cool air or equipment as required.

AC PLANT

FIRE PUMP HOUSEFire pump is a part of a fire system which stores water in case of emergency and pumps it through fire fighting units.

AC DUCT CENTRAL HEATING SYSTEMA central heating system provides warmth to the whole interior of a building (or portion of a building) from one point to multiple rooms. When combined with other systems in order to control the building climate, the whole system may be an HVAC

SUBSTATION

GENERATORElectric generator, a device that converts mechanical energy to electrical energy

FIRE EXTINGUISHERA fire extinguisher, or extinguisher, is an active fire protection device used to extinguish or control small fires

FIRE HOSE CABINATSA fire hose is a high-pressure hose that carries water or other fire retardant (such as foam) to a fire to extinguish it. Outdoors, it attaches either to a fire engine or a fire hydrant. Indoors, it can permanently attach to a building's standpipe or plumbing system.

FIRE SPRINKLERA fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded.

SMOKE DETECTORA smoke detector is a device that senses smoke, typically as an indicator of fire.

VENTILATORS