CONTINUOUS BEAD OF FIRESTONE

METAL COUNTERFLASHING BY OTHERS

ULTRAPLY TPO MEMBRANE

ULTRAPLY TPO BONDING ADHESIVE

NOTES:1.

REGULAR MAINTENANCE OF COUNTERFLASHING2.AND SEALANTS REQUIRED. NOT INCLUDED ASPART OF THE FIRESTONE WARRANTY.

CONTINUOUS BEAD OF AP SEALANT

CONTINUOUS BEAD OF FIRESTONE WATERBLOCK

WATERBLOCK

APPROPRIATE FIRESTONE FASTENER

FIRESTONE TERMINATION BAR

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.

12" (304.8 mm) O.C. MAX.

USE APPROPRIATE BASE TIE-IN

3" (76.2 mm) MIN. FACE (SEE NOTES)

METAL COUNTERFLASHING SHALL BE 24 GAUGE3.PRE-FINISHED STEEL OR .032" MIN. ALUMINUMFORMED WITH HEMMED LOWER EDGE.

12" (304.8 mm) O.C. MAX.

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPO

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

TM

MAXIMUM WARRANTY:

TERMINATION WITH SURFACE MOUNTEDCOUNTERFLASHING AND TERMINATION BAR

ALL

1/1/2006UT-T-6

20 YEARS

CONTINUOUS BEAD OF AP SEALANTOR HIGH GRADE SEALANT

WALL / CURB(MASONRY /CONCRETESUBSTRATE

ONLY)

MASONRY AND CONCRETEWALLS / CURBS MUST BE

WATERPROOFED ANDMAINTAINED IN ORDER

FOR ANY SURFACEMOUNTED TERMINATION

TO BE EFFECTIVE.

OR ULTRAPLY TPO GP SEALANT

APPROPRIATE FASTENER

4. INSTALL FIRESTONE TERMINATION BARWITH 1/4" (6.4 mm) GAP BETWEEN ADJOININGSECTIONS.

5. TERMINATION BAR MUST BE CUT AT INSIDE AND OUTSIDE CORNERS. DO NOT BEND

AROUND CORNERS.

6.

7. INSTALL METAL WORK IN ACCORDANCE WITHCURRENT SMACNA RECOMMENDATIONS.

TERMINATION BAR MUST BE FASTENED WITHIN1" (25.4 mm) MAX. OF ALL SECTION ENDS.

FIRESTONE INSULATION

SUBSTRATE

NOTES:1.

INSTALL METAL WORK TO MANUFACTURER'SREQUIREMENTS OR SMACNA RECOMMENDATIONS.

GP SEALANT IS REQUIRED ALONG ENTIRE UPSLOPE3.EDGE OF QUICKSEAM FLASHING WHEN ROOFSLOPE IS 1" (25.4 mm) PER FOOT OR GREATER.

ULTRAPLY TPO

ULTRAPLY TPO QUICKPRIME

DRIP/GRAVEL STOP EDGEMETAL (SEE NOTES)

CONTINUOUS CLEAT

4.

WALL

5.5" TPO QUICKSEAM FLASHING IF SHOP FABRICATED METAL EDGE IS USED ITMUST MEET ANSI/SPRI ES-1 OR AN FM STANDARD.

MEMBRANE

FLANGE OF METAL MUST BE FULLY SUPPORTED5.BY WOOD AND TERMINATED AT LEAST 1/2"(12.7 mm) FROM EDGE OF WOOD.

WOOD NAILER MUST BE INSTALLED TO MEETAPPLICABLE BUILDING CODES OR 200 LBS PERLINEAR FOOT MINIMUM IN ANY GIVEN DIRECTION.

ON BALLASTED ROOFS, GRAVEL STOP HEIGHT6.MUST MEET OR EXCEED BALLAST OR PAVERHEIGHT (2" (50.8 mm) MIN. ABOVE ROOF SURFACE).

1/2" (12.7mm) MIN.

1/2" (12.7mm) MIN.

1/4" (6.35 mm) TO1/2" (12.7 mm)

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.

2.1-1/4" HOT DIPPED GALVANIZED ROOFNAILS AT 4" (101.6 mm) O.C. MAX.

WOOD NAILER (SEE NOTES)

1-1/4" HOT DIPPEDGALVANIZED ROOF NAILSAT 6" (152.4 mm) O.C. MAX.

ISSUE / REVISIONDATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

Ul t r aPl y TPOTM

BUI LDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.comTM

MAXIMUM WARRANTY:

ROOF EDGE WITH FASCIA METAL BY OTHERS

ALL5/1/2010 UT-RE-20

20 YEARS

CONTINUOUS BEAD OFULTRAPLY TPO GPSEALANT (SEE NOTES)

CONTINUOUS BEAD OFULTRAPLY TPO GP

SEALANT (REQUIRED)

ULTRAPLY TPO BONDINGADHESIVE (ADHEREDSYSTEM ONLY)STOP (SEE NOTES)

OPTIONAL GRAVEL

IF THE FLANGE OF THE METAL EDGE IS NOT7.COMPLETELY COVERED WITH QUICKSEAMFLASHING, THEN AN ADDITIONAL PIECE OFQUICKSEAM FLASHING SHALL BE INSTALLEDAT ALL METAL SPLICES. REFER TO UT-RE-27.

THIS DETAIL IS APPROVED FOR A MAXIMUMOF 20 YEARS. REFER TO DETAIL UT-RE-21

FOR 25 YEAR REQUIREMENTS.

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

MAXIMUM WARRANTY:

PENETRATION WITH TPO PENETRATION POCKET KIT

ALL

1/1/2006UT-P-8

20 YEARS

FIRESTONE INSULATION

SUBSTRATE

FIRESTONE INSULATION

NOTES:1.

DO NOT USE OVER EXISTING PENETRATION POCKETS.4.

IF FIELD MEMBRANE IS CUT FOR INSTALLATION, THEMEMBRANE MUST BE REPAIRED WITH TPO MEMBRANEPRIOR TO INSTALLATION OF THE PENETRATION POCKET.MEMBRANE MUST BE INSTALLED WITHIN 1/2" (12.7 mm)

6.

OF PENETRATION.

PENE

TRAT

ION

PENE

TRAT

ION

7.

FIRESTONE POURABLE SEALER MOUNDED TO SHEDWATER (MINIMUM DEPTH OF 2" (50.8 mm), REMAINDER OFPOCKET MAY BE FILLED WITH A NON - SHRINKING GROUT.

3.

ULTRAPLY TPO QUICKPRIME REQUIRED ON PENETRATIONSAND MEMBRANE INSIDE OF PENETRATION POCKET.

PRE-MOLDED ULTRAPLY TPO PENETRATION POCKET

8.

6" (152.4mm)

REFER TO FIRESTONE WEBSITE FOR MOST CURRENTINFORMATION.

1" (25.4 mm) MIN.

NON-

SHRI

NKIN

G GR

OUT

ULTRAPLY TPO BONDING ADHESIVE

REMOVE ALL EXISTING FLASHINGS, LEADS, ETC. PIPE2.SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC.

DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS 180°F.5.REFER TO UT-P-6 & 7.

(ADHERED SYSTEM ONLY)

WELDED SPLICE 2" (50.8 mm) MIN.

SUBSTRATE

PRECUT PVC PIPE

FIRESTONE POURABLE SEALER

ULTRAPLY TPO QUICKPRIME (SEE NOTES)

ULTRAPLY TPO MEMBRANE

9. REFER TO UT-P-15 OR 16 FOR MAS.

SUBSTRATE

FIRESTONE INSULATION

SUBSTRATE

PENE

TRAT

ION

(HOT

STA

CK)

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPO

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

TM

MAXIMUM WARRANTY:

PENETRATION (HOT STACK) WITH ULTRAPLY TPOFLASHING (UNSUPPORTED)

ALL

1/1/2006UT-P-6

20 YEARS

1/2" -

1" (1

2.7 m

m - 2

5.4 m

m)

WELDED SPLICE2" (50.8 mm) MIN.

8" (2

03.2

mm) M

IN.

ULTRAPLY TPO FLASHING(UNSUPPORTED)

ULTRAPLY TPO BONDING ADHESIVE

STAINLESS STEELCLAMPING RING

CONTINUOUS BEADOF ULTRAPLY TPOGP SEALANT

INSULATED METALSLEEVE BY OTHERS

ULTRAPLY TPO BONDING ADHESIVE(SEE NOTES)

ULTRAPLY TPO MEMBRANE

NOTES:1.

REMOVE ALL EXISTING FLASHINGS, LEADS,2.ETC. PIPE SURFACE MUST BE FREE OF ALLRUST, GREASE, INSULATION, ETC.PIPE MUST BE ANCHORED TO ENSURE3.

NO WRINKLES OR FOLDS UNDER CLAMPING4.

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.

STABILITY.

RING.

FIELD FABRICATED METALHOOD BY OTHERS (REQUIRED)

FIRESTONE INSULATION

MEMBRANE AND INSULATION FOR FULLYADHERED SYSTEMS.

BONDING ADHESIVE REQUIRED BETWEEN5.

FIRESTONE FASTENER AND HD ORHD PLUS SEAM PLATE AT 12"

6.

(304.8 mm) O.C. MAX. (SEE NOTES)

FIRESTONE FASTENER AND HD SEAM PLATEREQUIRED FOR MAS ONLY. IF FASTENERCANNOT BE INSTALLED AS ILLUSTRATED,REFER TO DETAILS UT-P-15 & 16.

CONTINUOUS BEAD OFAP SEALANT OR HIGH

GRADE SEALANT

7.

(UNSUPPORTED) OR ULTRAPLYTPO MEMBRANE AS FLASHING

ULTRAPLY TPO FLASHING

WHEN REINFORCEMENT OF TPO MEMBRANEIS EXPOSED, REFER TO UT-LS-14 FOR CUTEDGE SEALANT APPLICATION.

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

MAXIMUM WARRANTY:

LAP SPLICE WITH 2" HAND WELD

ALL

1/1/2006UT-LS-2

20 YEARS

SLOPE

2" (50.8mm) MIN.

NOTES:1. REFER TO FIRESTONE WEB SITE FOR MOST

CURRENT INFORMATION.

WHEN POLYESTER REINFORCEMENT OF TPOIS EXPOSED, APPLY CUT EDGE TREATMENT TOENTIRE EXPOSED EDGE. REFER TO UT-LS-14.

2" (50.8mm) MIN.

6" (152.4 mm)

FIRESTONE FASTENER ANDHD OR HD PLUS SEAM PLATE

SLOPE 2" (50.8mm) MIN.

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

MAXIMUM WARRANTY:

LAP SPLICE WITH 1-1/2" AUTOMATIC WELDER

ALL

1/1/2006UT-LS-1

20 YEARS

SLOPE

1-1/2" (38.1mm) MIN.

NOTES:1. REFER TO FIRESTONE WEB SITE FOR MOST

CURRENT INFORMATION.

WHEN POLYESTER REINFORCEMENT OF TPOIS EXPOSED, APPLY CUT EDGE TREATMENT TOENTIRE EXPOSED EDGE. REFER TO UT-LS-14.

2" (50.8mm) MIN.

6" (152.4 mm)

FIRESTONE FASTENER ANDHD OR HD PLUS SEAM PLATE

SLOPE 1-1/2" (38.1mm) MIN.

NOTES:1.

2.

USE APPROPRIATE

BASE TIE-IN DETAIL

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.WELDED SPLICE (SEE NOTES)

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTS

NOBODY COVERS YOU BETTER.www.firestonebpco.com

TM

MAXIMUM WARRANTY:

INSIDE CORNER

ALL

1/1/2006UT-C-5

20 YEARS

REFER TO DETAIL UT-LS-1 OR 2 FOR WELDWIDTH.

USE APPROPRIATE TERMINATION DETAIL

ULTRAPLY TPO MEMBRANE

PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)

3. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A MAXIMUM WARRANTY OF 15 YEARS .

4. WHEN REINFORCEMENT OF TPO MEMBRANEIS EXPOSED, REFER TO UT-LS-14 FOR CUTEDGE SEALANT APPLICATION.

USE APPROP.BASE TIE-IN

NOTES:1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION.

REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.

ULTRAPLY TPO 18" CURBFLASHING OR MEMBRANE HEAT

WELDED TO ULTRAPLY TPO

ULTRAPLY TPO MEMBRANE

ULTRAPLY TPO T-JOINT COVERWELDED IN PLACE (SEE NOTES)

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

MAXIMUM WARRANTY:

INSIDE CORNER WITH CONTINUOUS WALL FLASHING

ALL

1/1/2006UT-C-4

20 YEARS

PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)

3. T-JOINT COVER REQUIRED FOR .060 GAUGE MEMBRANE ONLY.4. ULTRAPLY TPO FLASHING (UNSUPPORTED) (4"x4" MIN. WITH

ROUNDED CORNERS) MAY BE USED IN LIEU OF T-JOINT COVER.

DETAIL

(FIELD SHEET)

USE APPROPRIATE TERMINATION DETAIL

5. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A

MAXIMUM WARRANTY OF 15 YEARS .6. WHEN REINFORCEMENT OF TPO MEMBRANE IS EXPOSED, REFER

TO UT-LS-14 FOR CUT EDGE SEALANT APPLICATION.FIELD SHEET (SEE NOTES)

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTS

NOBODY COVERS YOU BETTER.www.firestonebpco.com

TM

MAXIMUM WARRANTY:

OUTSIDE CORNER

ALL

1/1/2006UT-C-1

20 YEARS

USE APPROPRIATE

TERMINATION DETAIL

USE APPROPRIATE

BASE TIE-IN DETAIL

PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)

NOTES:1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT

INFORMATION.REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.

ULTRAPLY TPO 18" CURB FLASHINGOR MEMBRANE HEAT WELDED TOULTRAPLY TPO FIELD SHEET (SEE NOTES)

ULTRAPLY TPO MEMBRANE (FIELD SHEET)

3. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A MAXIMUM WARRANTY OF 15 YEARS .

4. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.

FIRESTONE INSULATION

SUBSTRATE

WALL / CURB

NOTES:1.

3.

WELDED SPLICE (SEE NOTES)

ULTRAPLY TPO MEMBRANE

ULTRAPLY TPO BONDING ADHESIVE (SEE NOTES)

USE APPROPRIATETERMINATION

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.

POSI

TION

PLA

TE 1/

2" (1

2.7 m

m)

MIN.

ABO

VE F

INIS

HED

ROOF

ULTRAPLY TPO MEMBRANE MUST EXTEND1/2" (12.7 mm) BEYOND HD OR HD PLUS SEAM PLATE (SEE NOTES)

ULTRAPLY TPO BONDING ADHESIVE

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPO

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

TM

MAXIMUM WARRANTY:

BASE TIE-IN WITH HD SEAM PLATES FASTENEDTO WALL / CURB

ALL

1/1/2006UT-BT-2

20 YEARS

4.

REFER TO UT-BT-16 & 17 FOR MEMBRANESECUREMENT AT CORNERS.

FIRESTONE FASTENER AND HD OR HD PLUS SEAMPLATE AT 12" (304.8 mm) O.C. MAX. (SEE NOTES)

ULTRAPLY TPO 18" CURB FLASHING OR MEMBRANE

BONDING ADHESIVE REQUIRED BETWEEN MEMBRANEAND INSULATION FOR FULLY ADHERED SYSTEMS.

5. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.

FIRESTONE INSULATION

SUBSTRATE

WALL / CURB

NOTES:1.

MAXIMUM 6" (152.4 mm) LONG FASTENERS.3.(NOTE: WOOD BLOCKING MAY BE SUBSTITUTEDFOR INSULATION TO REDUCE FASTENER LENGTH REQUIREMENT).

4.

6.

WELDED SPLICE (SEE NOTES)

ULTRAPLY TPO MEMBRANE

ULTRAPLY TPO BONDING ADHESIVE (SEE NOTES)

USE APPROPRIATETERMINATION

BONDING ADHESIVE REQUIRED BETWEEN MEMBRANEAND INSULATION FOR FULLY ADHERED SYSTEMS.

REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.

ULTRAPLY TPO BONDING ADHESIVE

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTSNOBODY COVERS YOU BETTER.

www.firestonebpco.com

TM

MAXIMUM WARRANTY:

BASE TIE-IN WITH HD SEAM PLATES FASTENED TO DECK

ALL

1/1/2006UT-BT-1

20 YEARS

REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.

FIRESTONE FASTENER AND HD OR HD PLUS SEAMPLATE AT 12" (304.8 mm) O.C. MAX. (SEE NOTES)

ULTRAPLY TPO 18" CURB FLASHING OR MEMBRANEIN CASE OF OBSTRUCTION REFER TO DETAIL UT-BT-5.

5. REFER TO UT-BT-16 & 17 FOR MEMBRANESECUREMENT AT CORNERS.HD OR HD PLUS SEAM PLATE POSITIONED

1/2" (12.7 mm) BEYOND WALL/CURB

7. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.

NOTES:1.

HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF 1/2"2.

INSULATION ADJACENT TO DRAIN TO BE APPROPRIATE3.FIRESTONE INSULATION WITH APPROPRIATE BONDING

FIRESTONE WATERBLOCK MIN. OF 1/2 OF 10 OZ (295 ml)4.

IN REROOF APPLICATIONS:5.- REMOVE EXISTING FLASHINGS DOWN TO METAL BOWL- REPAIR OR REPLACE BROKEN DRAIN COMPONENTS- DRILL AND TAP BROKEN DRAIN BOLTS AND REPLACE

(12.7 mm) BEYOND CLAMPING RING AND SHOULD NOT BE

IF NECESSARY.

SUBSTRATE

FIRESTONE INSULATION

ULTRAPLY TPO BONDING

ULTRAPLY TPO

CONTINUOUS BEAD OFFIRESTONE WATERBLOCK

COMPRESSION RINGSTRAINER BASKET

FIRESTONE INSULATION

SUBSTRATE

SURFACE.

TUBE PER 4" DRAIN. USE ADDITIONAL WATERBLOCK

SMALLER THAN THE DIAMETER OF THE LEADER PIPE.

FOR LARGER DRAINS.

1/2" (12.7mm) MIN.SEE NOTES

REFER TO FIRESTONE WEB SITE FOR MOST CURRENTINFORMATION.

(SEE NOTES)

MEMBRANE

12" (304.8 mm)

ADHESIVE (ADHERED

ISSUE / REVISION

DATE:

NOT TO SCALEACCEPTABLE SYSTEMS:

DETAIL NO.

UltraPly TPOTM

BUILDING PRODUCTS

NOBODY COVERS YOU BETTER.www.firestonebpco.com

TM

MAXIMUM WARRANTY:

ROOF DRAIN

ALL

1/1/2006UT-D-1

20 YEARS

SYSTEMS ONLY)

IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) OF DRAIN COMPRESSION RING, TPOTARGET PATCH REQUIRED.IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) TO 18" (457.2 mm) OF DRAIN COMPRESSIONRING, HEAT WELD A LAYER OF ULTRAPLY TPO FLASHING (UNSUPPORTED) OR ULTRAPLY

SUMP AREA FIELD SEAM REQUIREMENTS:

A.

B.

TPO MEMBRANE CENTERED OVER SEAM EDGE. FLASHING MUST EXTEND 3" (76.2 mm) MIN.BEYOND EDGE OF SUMP.

1" MAX.(25.4 mm)

A3.1

TPO Roof Details