How to enter the IPs for ERICSSON link when it down management:

After log on the link, right click on the link name (as the link is down management, the name won’t appear, only the IP saved on it will appear):

Choose (Configure Basic NE) as follow:

The (Basic NE) page will appear as follow:

Click on (NE Name) to change the link name:For example: (TN-UP0428MN-MENYA3)

Click on (NE Location) to change the link region:For example: (MENYA)

Click on (NE Contact), and the NE Contact is ERICSSON:Always be: (ERICSSON)

Click on (NE IP Address) to enter the link IP address:For example: (10.208.34.201)

Click on (NE Subnet Mask) to change the subnet IP address:Always be: (255.255.255.248)

Click on (Default Gateway) to enter the gateway IP address:Always be: (0.0.0.0)

Click on (Continent) to change the link country:Always be: (Etc)

Click on (City) to change the region timing:Always be: (GMT +2)

Click on (NTP Server) to change the NTP Server IP address:Always be: (10.158.204.18)

Click on (Date and Time) to adjust the time and date of the link:Click on the mention sign, the time and date will be adjusted automatically:

Then press (Save) to save the changes:

A message will appear to sure that we need to save changes, and we will press (OK):

Another message will appear to inform us that the link will make warm restart, and we will press (OK):

During warm restart we will loose the connection to the link:

The connection will back again after warm restart (about 10 mins.) and then we will press (OK) to continue:

Right click on the link name and choose:Configure ------- DCN ------- OSPF Areas

A DCN-Configure OSPF Areas page will appear, and then we will press the mentioned sign to create new OSPF Area:

Click on (Net Address) to enter the link IP:We will enter the link IP but last number will be (0):For example: (10.208.34.0)

Click on (Subnet Mask) to enter the subnet IP:Always be: (255.255.254.0)

Click on (Area ID) to enter the link area IP:We will enter the link IP but last number will be (0):For example: (10.208.34.0)

Click on (Area Type):Always be: (Totally Stubby)

Then press (Save) to save the changes:

No we need to warm restart the link, Right click on the link name and choose:Tools ---------- Restart

Click on (Warm Restart) button, then press (OK) to begin the restart action:

The warm restart will begin and take about 10 mins:

During warm restart we will loose the connection to the link:

The connection will back again after warm restart (about 10 mins.) and then we will press (OK) to continue:

To make sure that the link is under supervision now we can use (Ping) command from DOS session as follow:Start Menu ----> All programs ----> Accessories ----> Command Prompt

A DOS session will be opened and we will write:>> ping 10.158.204.18

If the link ping normal as follow, so the site will be under supervision and the problem will be solved and then we can check with E// team: