VESDAVESDAWhen Performance Counts

PA VISION SDN BHD Fire Safety

VESDAVESDA®®

• Very Early Smoke Detection Apparatus

• Market Leaders In Early Warning Smoke Detection

• Founders of Aspirating Technology as we know it today. Building Air Sampling Systems for 30 years

PA VISION SDN BHD Fire Safety2

today. Building Air Sampling Systems for 30 years

• Recognised worldwide as the global benchmark technology

• Focus on Customer Support & Loss Prevention Engineering

What is Aspiration Smoke Detection?

PA VISION SDN BHD Fire Safety3

A system which draws air from an area, via a

pipe network, to a central detector which

monitors for small amounts of smoke

What is Aspiration Smoke Detection?

PA VISION SDN BHD Fire Safety4

VESDA is early warning…..

PA VISION SDN BHD Fire Safety5

• Absolute smoke detection

– once only calibration

– alarm thresholds set to defined smoke

obscuration levels

Features of VESDA

PA VISION SDN BHD Fire Safety6

• The widest sensitivity range

– 0.005 to 20% Obs/m (0.0015 to 6% Obs/ft)

– alarm threshold setting to suit different

environments (inc AutoLearn)

• Dual stage filter technology

– 1st to remove dust from air sample

– 2nd to provide clean air barriers to protect optical

components inside the detector

Features of VESDA

PA VISION SDN BHD Fire Safety7

• Comprehensive Display (LCD & Bar graph)

• High efficiency aspirator

• Intelligent communications (VESDAnet)

VESDAnet

PA VISION SDN BHD Fire Safety8

• Earliest detection - avoid down time

• Avoid unnecessary suppression release

• Extra time is required for safe evacuation

• Smoke is difficult to detect

Why use aspiration smoke detection

PA VISION SDN BHD Fire Safety9

• Smoke is difficult to detect

• Environmentally challenging areas

• Concealed detection is important

• Maintenance access is limited

Critical processes cannot incur disruption orCritical processes cannot incur disruption or

down timedown time

TelecommunicationsTelecommunications

Computer roomsComputer rooms

Earliest detection avoid down time

PA VISION SDN BHD Fire Safety10

Computer roomsComputer rooms

Banking operationsBanking operations

Production facilitiesProduction facilities

Early warning gives time to investigate and

avoid unnecessary suppression release

Telecommunication

Data Centres

Avoid unnecessary suppression release

PA VISION SDN BHD Fire Safety11

Data Centres

Equipment rooms

Electrical sub-stations

Environments where rapid exit is impeded

Underground Stations

Theatres

Public buildings

Extra time required for evacuation

PA VISION SDN BHD Fire Safety12

Public buildings

Churches

Environments with high ceilings, high air

flows or vast open areas provide unique

characteristics

Clean rooms

Smoke is difficult to detect

PA VISION SDN BHD Fire Safety13

Clean rooms

Warehouses

Aircraft hangers

Computer rooms

Atria

Aggressive environments with high levels of

pollution or extreme temperature conditions

Cold Stores

Production areas

Environmentally challenging areas

PA VISION SDN BHD Fire Safety14

Production areas

Paper mills

Underground tunnels

Mines

Industrial Plants

Interiors can not be spoilt by unsightly

conventional detectors

Casinos

Cathedrals

Concealed detection is important

PA VISION SDN BHD Fire Safety15

Cathedrals

Stately Homes

Museums

Art Galleries

Modern Office Buildings

Where access to the detection area is difficultWhere access to the detection area is difficult

WarehousesWarehouses

Ceiling voidsCeiling voids

Production machineryProduction machinery

Maintenance access is limited

PA VISION SDN BHD Fire Safety16

Production machineryProduction machinery

EMC Controlled areasEMC Controlled areas

Reference Sites

Telecommunication

Automotive

Wafer Fab

Power Generation

Oil & Gas

PA VISION SDN BHD Fire Safety17

Oil & Gas

Banking

Museum

Library

Hospital

Entertainment

Reference Sites Telecommunication Industry

Telstra Australia

British Telecom

AT&T Worldwide

Bell Corporation

MCI Corporation

Cable and Wireless

New Zealand Telecom

PA VISION SDN BHD Fire Safety18

New Zealand Telecom

Nippon Telecom

Telekom Malaysia

Singapore Telecom

China Telecom

China Mobile

China Unicom

General Motors Corp Various sites

General Motors Holden Adelaide

Toyota Melbourne

Ford Melbourne

Mitsubishi Adelaide

Chrysler Illinois

AC Delco Various sites

Reference Sites Automotive Industry

PA VISION SDN BHD Fire Safety19

AC Delco Various sites

Honda Various sites

Saab Sweden

Daihatsu Various sites

Volvo Sweden

Peugeot France

MAN Trucks Germany

Singapore SSMC, Charter FAB 3, Charter FAB 7, ST Micro, UMC

Malaysia 1st Silicon, Silterra

Philippines Seagate, Intel, Maxtor and others

UK Hyundai, Intel, Motorola, Phillips, ShinEtsu, NEC

US Wafer Fab RFMD

Taiwan PSMC, TECO, TSMC, UMC, USC, Windbond,

Reference Sites Wafer Fab Industry

PA VISION SDN BHD Fire Safety20

Taiwan PSMC, TECO, TSMC, UMC, USC, Windbond,

WSMC, Phoenixtec Eng, E-Tron

Reference Sites Power Generation

UK Berkeley Nuclear Power Station

Europe CERN Atomic Particle Accelerator

UK Sellafield Nuclear Power Station

Australia Loy Yang “A” Power Station Coal Fired

Australia Tumut Hydro Power Station

Australia Murray Hydro Power Station

PA VISION SDN BHD Fire Safety21

Australia Murray Hydro Power Station

Australia Jeeralang Power Station Gas Fired

Australia Newport Power Station Gas Fired

Reference Sites Oil & Gas Industry

Petronas

British Gas-Transco

Zeneca

ICI Headquarters

British Petroleum HQ

Shell Petroleum (worldwide)

PA VISION SDN BHD Fire Safety22

Shell Petroleum (worldwide)

ExxonMobil (worldwide)

BHP

Reference Sites Banking Industry

Hong Kong Shanghai Banking Corporation

Australia and New Zealand Bank (ANZ)

National Australia Bank

Standard Chartered Bank

Treasury Finance Department

Saudi Cairo Bank

Saudi Holland Bank

PA VISION SDN BHD Fire Safety23

Saudi Holland Bank

London Stock Exchange

Commonwealth Bank

Reserve Bank Australia

US Treasury Dept

Reference Sites Library

UK Bristol Library

Spain Colegio Notaris Library Barcelona

Australia Victorian State Library Melbourne

Australia National Library Canberra

Australia Parliament House (old) Archive Library

USA Wilson Library Minnesota

USA Secure Data Services (SDS)Media Lib.

PA VISION SDN BHD Fire Safety24

USA Secure Data Services (SDS)Media Lib.

Reference Sites Museums

Shelburne Museum

S.S. Ticonderoga, a National Registered Historic Site

The Isabella Stewart Gardner Museum

The National Gallery Victoria Australia

The National War Museum Canberra Australia

American Museum Planetarium

Aylsebury Museum

PA VISION SDN BHD Fire Safety25

Aylsebury Museum

Bonneville City Museum

Museum of Scotland

Reference Sites Hospitals & Pharmaceutical

Royal Darwin Hospital

Queen Elizabeth Hospital Adelaide

Royal Melbourne Hospital

All MRI Facilities in Australia

ABC Hospital - Computer Room - Mexico

Beaumon Hospital - Computer Room - MI - USA

PA VISION SDN BHD Fire Safety26

Burnside War Memorial Hospital - Australia

Commonwealth Serum Laboratories (CSL) Australia

University Medical Center AZ Tucson USA

Westmead Hospital Australia

Royal Childrens Hospital MRI Australia

Eventide Nursing Home Ward protection Australia

Albury Diagnostic Centre MRI NSW Australia

Reference Sites Entertainment

Adelaide Entertainment Centre Australia

ADS Channel 10, South Australia

Crown Center & Development, Kansas City Kansas USA

Joint European Torus (JET) UK

Jupiters Casino Gold Coast, Queensland Australia

PA VISION SDN BHD Fire Safety27

VESDA LaserFOCUS (VLF-250 & 500)

Single sampling pipe

Pipe length 25m

250m2 area coverage

LED display

Bar graph display

PA VISION SDN BHD Fire Safety28

Single sampling pipe

Pipe length 50 m

500m2 area coverage

LED display

Bar graph display

VESDA LaserCOMPACT

Single sampling pipe

Pipe length 50m

500m2 area coverage

LED display

VESDAnet option

PA VISION SDN BHD Fire Safety29

VESDA LaserPLUS

4 sampling pipes

Pipe length 200m

2000m2 area cov.

Bar graph display

LED display

Programmer option

PA VISION SDN BHD Fire Safety30

Programmer option

VESDAnet

VESDA LaserSCANNER

4 sampling pipes

Pipe length 200m

Scanning option

Zone identification

2000m2 area cov.

Bar graph display

PA VISION SDN BHD Fire Safety31

Bar graph display

LED display

Programmer option

VESDAnet

Pipe fittings and accessories

PA VISION SDN BHD Fire Safety32

Pipe fittings and accessories

PA VISION SDN BHD Fire Safety33

Mounting clip options

Saddle Clip Pipe Clip Offset Clip

PA VISION SDN BHD Fire Safety34

Sampling point location

PA VISION SDN BHD Fire Safety35

Country Agency Standard Status

Australia SSL AS 1603.8 -1998 Passed

USA UL UL 268 : 1996 Passed

Approvals

PA VISION SDN BHD Fire Safety36

USA UL UL 268 : 1996 Passed

USA FM FM 3830 : 1997 Passed

Canada ULC UL 268 : 1996 Passed

UK LPCB TE 89423 Passed

Germany VdS CEA GEI 1-048 Passed

France AFNOR NFS 61-950 Passed

China NTC GB-4717-93 Passed

All components of the VESDA system have been designed

to meet or exceed the following EMC standards

Country EMC standard Type

Australia AS/NZS 3548 Emissions

EMC Compliances

PA VISION SDN BHD Fire Safety37

SMA tick AS 2362.7 Immunity

USA & Canada FCC Class B Emissions

(CISPR 22-B)

UK & Europe EN 50081-1 Emissions

EN 50130-4 Immunity

CE Mark EN 54-7 Immunity

Siemens VESDA

PA VISION SDN BHD Fire Safety38

Authorised distributor

Why choose Siemens…..

Since October 2004 Vision System has appointed Siemens

(Building Technologies) as the global distributor for VESDA.

Siemens will provide marketing and technical support to

customers which includes engineering, design, installation,

PA VISION SDN BHD Fire Safety39

commissioning and after sales service.

Application examples (cabinet protection)

PA VISION SDN BHD Fire Safety40

Application examples (cabinet protection)

PA VISION SDN BHD Fire Safety41

Application examples (refrigeration)

PA VISION SDN BHD Fire Safety42

Application examples (in-rack sampling)

PA VISION SDN BHD Fire Safety43