Floor covering
NASAHI AAC floor panel
Floor penetration
Blocking for panel support
Timber or steel joist @ 450 or 600mm centres maximum
Blocking forpanel support
Walsc AAC Flooring System Overview
SYSTEM FEATURES
Fast and cost effective construction;
High-performance lightweight flooring system;
NCC (BCA) complaint;
Premium solid, comfortable and quiet;
Great thermal performance.
Note: For wall system specification, please refer to “Walsc AAC Flooring System - Design and Installation Guide” which is available online www.walsc.com.au.
AAC Flooring System
for Low-rise Residential Buildings
1 2
3 4
5
6
Project Portfolio
1. VISUM Apartments, Auburn Builder: Loulach Developments Application: High-rise Facade and Internal Wall.2. Hope Gardens, Penrith Builder: Dynamic Projects Application: High-rise Facade and Internal Wall.3. ZEN Apartments, Wentworth Point Builder: Billbergia Application: High-rise Internal Wall.4. COMO Apartments, Homebush Builder: City Built Group Application: High-rise Facade Wall.5. The Jewel Apartments, Roselands Builder: ALAND Developments Application: High-rise Facade and Internal Wall.6. Belmore 510 Apartments, Belmore Builder: ESA Builders Application: High-rise Internal Wall.
Walsc Australia Pty LtdABN: 52 160 666 366 D3, 27 Fariola Street, Silverwater, NSW 2128Tel: 1300 957 566 Fax: 02 8246 3486
Technical Support: 1300 957 566 info@walsc.com.au
www.walsc.com.auThe latest version of this manual is available at walsc.com.au
WALSC®
AAC WALL SYSTEMS
Distribution Network available in NSW, SA, QLD, and other states in Australia.
Exclusively Distributed (NSW) by:
Hume Plasterboard Pty LtdABN: 70 101 562 27086 Ferndell Street, South Granville NSW 2142
For Sales and Service Contact13 4863info@humeplaster.com.au
Insulation
13mm plasterboard lining(min. density 8.4kg/m²)
Timber / Steel structural frame
Option 2:
Base Details*:Option 1:
continuous steel channel 76x28x0.75mm fixed with masonry anchors at 600mm max. ctrs
aluminium wall brackets.
*See Figure 11.2 (a) (b) and (c).
75mm NASAHI AAC Panel
13mm plasterboard lining (min. density 8.4kg/m²)
Aluminium wall brackets
Full Support & Services
We offer sales services, technical advice and supportto meet the clients’ satisfaction
Full Support
Environmentally Friendly
Eco-friendly
Less greenhouse gas emissionsthan the comparative products,concrete and brick
Lightweight & Durability
NASAHI AAC Panel weight 1/4 the weight of bricks 1/5 of standard concreteAmbient Density 600kg/m³
Light Weight
Termite & Pest Resistance
NASAHI AAC Panel will not be damaged by termites or other insects due to its unique structure and natural featuresTermite Resistance
Moisture Resistance
NASAHI AAC Panel effectively prevent water from penetrating through it
Moisture Resistance
Acoustic Insulation
NASAHI AAC Panel 75 mm panel only:Rw 35 dB AAC Wall Systems:RW + Ctr > 50 dB
Thermal Insulation
NASAHI AAC Panel (75 mm) R-Values 0.52 over 4×betterthan 110mm Brick (0.12)
Fire Resistance
75mm Panel only: FRL -/90/9075mm Panel (T&G, caged mesh): FRL -/120/120100mm Panel only: FRL -/240/240Fire Resistance
Note: For wall system specification, please refer to “Walsc High-rise Internal Wall Systems - Design and Installation Guide” which is available online www.walsc.com.au.
Walsc High-rise Facade Wall System Overview
Walsc Low-rise Inter-Tenancy Wall System Overview
Walsc External Wall Cladding System Overview
Roof framing
75mm NASAHI AAC Panel
Structural wall frame
Upper floor sheeting
Continuous horizontal steel batten
Horizontal control joint
Upper floor framing
Walsc approved coating system
Concrete slab
Flashing and damp-proof course
Building wrap/sarking as specified
Internal Cavity Wall System
for Apartment and Commercial Buildings
High-rise Facade Wall System
for Apartment and Commercial Buildings
Inter-Tenancy Wall System
for Multi-Residential Buildings
External Wall Cladding System
for Multi-Residential Buildings
SYSTEM FEATURES
Rw+Ctr > 50 for walls separating Sole Occupancy Units (SOUs);
Discontinuous construction therefore can separate wet areas, lift shaft, plant rooms, etc.;
Wall system achieve FRL -/120/120 with 13mm fire-rated plasterboard linings on both sides;
75mm Square Edge panel only achieve FRL -/90/90 mins;
100mm Square Edge panel only achieve FRL -/240/240 mins;
75mm Tongue and Groove caged reinforced panel achieve FRL -/120/120 mins.
Concrete soffit
15m
m m
ax
13 mm standard plasterboardlining minimum mass 8.5kg/m²
75 mm NASAHI AAC Panel
As specified
Concrete slab
Concrete soffit
Ceiling system
or 6mm FC in the wet area.
P50 shadow-linestopping angle
A Typical Walsc Internal Cavity Wall System Overview
SYSTEM FEATURES
Designed in accordance with AS5146-2016;
NCC (BCA) complaint;
Achieve FRL 90/90/90 mins;
Moisture resistance;
Energy efficiency;
Fast construction.
SYSTEM FEATURES
Meet the NCC (BCA) requirements;
Achieve FRL 90/90/90 mins;
Better acoustic performance;
Energy efficiency;
Fast and cost effective construction.
SYSTEM FEATURES
Green and premium wall cladding material
Stylish finishes with choices of coating system
Energy efficiency
Fast and cost effective construction
Waterproofing/Moisture resistance
Termite resistance
Walsc approvedcoating system
Horizontal control joint
75 mm NASAHI AAC Panel
Structural frame
Steel top hat/batten
Building wrap/sarking as specified
Steel shelf anglefixed to slab edge
Internal lining
Rebated slab edge
Sealing tape
Base flashing
Note: For wall system specification, please refer to “Walsc High-rise Facade Wall System - Design and Installation Guide” which is available online www.walsc.com.au.
Note: For wall system specification, please refer to “Walsc Low-rise Inter-Tenancy Wall System - Design and Installation Guide” which is available online www.walsc.com.au.
Note: For wall system specification, please refer to “Walsc Low-rise External Wall Cladding System - Design and Installation Guide” which is available online www.walsc.com.au.
Steel top hat/batten
Concrete slab
Damp proof course and thin bed mortar
The Walsc Inter-Tenancy Discontinuous Wall System consists of NASAHI AAC Panels installed vertically and fixed to the structural frame on each side using aluminium brackets as shown. Walsc AAC Panel Adhesive is applied to the vertical edges where there is an adjoining panel.
√ CodeMark accredited
√ In compliance with AS 5146
√ NCC/BCA compliant
√ Tested for Fire/Acoustic/Weatherproofing
√ Outstanding performance
√ Technical support
CodeMark Certification:
(CM40126)
√ CodeMark accredited
√ In compliance with AS 5146
√ NCC/BCA compliant
√ Tested for Fire/Acoustic/Weatherproofing
√ Outstanding performance
√ Technical support
CodeMark Certification:
(CM40126)
√ CodeMark accredited
√ In compliance with AS 5146
√ NCC/BCA compliant
√ Tested for Fire/Acoustic/Weatherproofing
√ Outstanding performance
√ Technical support
CodeMark Certification:
(CM40126)
√ CodeMark accredited
√ In compliance with AS 5146
√ NCC/BCA compliant
√ Tested for Fire/Acoustic/Weatherproofing
√ Outstanding performance
√ Technical support
CodeMark Certification:
(CM40126)
Project Portfolio
Product Benefits NASAHI AAC Panel is quick and easy to install, cost efficient objective can be achieved
Cost Savings
Cost SavingsShortened Construction Period
Time Saving
NASAHI AAC Panel enables labourers install fast and promotes the efficiency during the construction time of the project
Product Benefits
top related