water tank inspection standards & guidelinestank industry consultants awwa d101-53 (retired)...

Post on 29-Feb-2020

5 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Tank Industry Consultants

Water Tank Inspection Standards &

GuidelinesPenni Snodgrass

Sales and Marketing ManagerTank Industry Consultants

Tank Industry Consultants

AWWA D101-53 (retired) Inspecting and Repairing Steel Water Tanks,

Standpipes, Reservoirs, and Elevated Tanks, for Water Storage

First Edition – 1953 Reaffirmed without revision in 1986 Withdrawn – December, 1998 Currently undergoing complete revision

Tank Industry Consultants

AWWA D101Inspection of Water Tanks and

Related Facilities

Committee Chair – Chip Stein, TIC

How AWWA Standards are Developed

Tank Industry Consultants

Tank Industry Consultants

AWWA Standards are not…

Specifications Endorsement Recommendation

Tank Industry Consultants

Standards vs Specs

Standards - minimum technical requirements ( i.e. the “what”)

Specifications – the contractual relationships ( i.e. “when” and “by whom” and through standards and supplemental requirements –the “what”)

Tank Industry Consultants

AWWA Standards are…

Guidelines Solid Base Frequently cited in project specifications A reliable source of information

Tank Industry Consultants

Standards-Making Process

Standards Committee

Producer Group Consumer Group General Interest

Tank Industry Consultants

Standards-Making Process

Committee Consensus Sent to Standards Council, if approved Published for Review and Comment Sent to Executive Committee Published …start the process all over

Tank Industry Consultants

Standards Council

Publish

CommitteeConsensus

PublicReview and Comment

ExecutiveCommittee

Five-Year Review/Revision

Tank Industry Consultants

What’s Happening in the D101 Committee??

Tank Industry Consultants

Types of Structures

Clearwells Concrete Tanks Bolted Tanks Membrane Covered Reservoirs Stainless Steel Tanks (bolted and welded) Filter Beds Hydropneumatic Tanks (operating at less than 15

psi) Clarifiers Current Market Demand

Tank Industry Consultants

Proposed Foreword

Stated Purpose of Standard Asset Management Approach Goal of Sustainability References to C652, D100, D102, D103,

D107, D110

Tank Industry Consultants

Proposed Section AElements of Facilities

Nomenclatures Elements

Tank Industry Consultants

Proposed Section BInspection of New Construction

Soils/Geotech Documentation/Work-In-Process Evaluation

Reporting Inspections specific to type of construction

♦Welding♦Concrete Placement♦Coatings

Tank Industry Consultants

Proposed Section CInspection of Existing Structures

Frequency Coatings Structural Sanitary Safety Tank and Site Security Reporting Requirements

Tank Industry Consultants

Inspection Methods

Underwater Tank Evaluation In-Service Cleaning, as it relates to the inspection

of the structure Rafting Commentary Checklist - advantages and

disadvantages of Dive, ROV, and Drained Methods Commentary - Owner Specify Motivation for

having Tank Inspected

Tank Industry Consultants

Accessories

Cathodic Protection Mixing Systems

Tank Industry Consultants

Proposed Section DInspection of Existing Tank

Rehabilitation Submittal Review Appurtenance and Welding Repairs Repairs Surface Preparation Emission and Overspray Containment Air Monitoring – Environmental and Personnel Air Safety Coating Application Ventilation during Coating Application Documentation/Work-In-Process Evaluation

Reporting Punch Lists

Tank Industry Consultants

Proposed Section EFirst Anniversary Evaluation

Minimum requirements for how this evaluation should be conducted and reported Type – Drained, ROV, Dive Disinfection Reporting

Tank Industry Consultants

Proposed Section FQualifications

Engineering Firm♦Experience♦Insurance♦Licensed Engineer

Inspector♦Experience♦Climbing Ability♦Association Certifications (NACE, SSPC)

Tank Industry Consultants

Proposed Appendices

Bibliography Organizations Cold Weather Operation of Water Tanks Cellular Antennas Considerations Site Selection Tank Style Analysis Tank Sizing Considerations Sample Inspection Forms Inspection Certifications and Associations Commentary

Tank Industry Consultants

AWWA M42 –Steel Water-Storage Tanks

First Edition – 1988 Latest Revision – 2012 Frequency (3 to 5 years) Inspector Qualifications Inspection Scope AWWA D101 Referenced in Appendix C Revision Chair, Chip Stein, TIC

Tank Industry Consultants

Steel Water Storage Tanks

Published by McGraw Hill in conjunction with AWWA

Technical Editor – Steve Meier Chapter Author – Chip Stein Chapter Author – Jennifer Coon

Tank Industry Consultants

NFPA 25 (2017) – Standard for the Inspection, Testing, and Maintenance of

Water-Based Fire Protection Systems Frequency

♦ Daily – Heating System♦ Weekly – Water Temperature♦ Monthly – Water Level♦ Quarterly – Tank Exterior, Support Structure,

Catwalks/Balconies, Ladders, Site♦ Annually – Expansion Joints, Coatings♦ Interiors – 3 years vs 5 years

Tank Industry Consultants

NFPA and AWWA Differences

Frequency Site Evaluation (combustible storage, brush, fire

exposure hazard) NFPA addresses all types of tank construction NFPA requirements not found in AWWA

♦Holiday Detection♦Underbottom Ultrasonic Testing (or Coupon Removal)♦Vacuum-Box Testing of Floors (NFPA 22)