an experimental exercise on european sterility

25
An Experimental EXERCISE on European Sterility Luca Stanco – INFN Padova Beyond Three Neutrino Family Oscillations ehalf of a motivated group of Italian Staff Physici LNGS Workshop 3-4 May 2011 1

Upload: dora-doyle

Post on 03-Jan-2016

25 views

Category:

Documents


0 download

DESCRIPTION

Beyond Three Neutrino Family Oscillations. LNGS Workshop 3-4 May 2011. An Experimental EXERCISE on European Sterility. Luca Stanco – INFN Padova. on behalf of a motivated group of Italian Staff Physicists. Bertolin ( 5 ) , R. Brugnera (5,6), S. Dusini ( 5 ) , - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: An Experimental EXERCISE  on European Sterility

An Experimental EXERCISE on European Sterility

An Experimental EXERCISE on European Sterility

Luca Stanco – INFN Padova

Beyond Three Neutrino Family Oscillations

on behalf of a motivated group of Italian Staff Physicists

LNGS Workshop 3-4 May 2011

1

Page 2: An Experimental EXERCISE  on European Sterility

A.Bertolin (5), R. Brugnera (5,6), S. Dusini (5), R.A. Fini (1), A. Garfagnini (5,6), M. Laveder (5,6), A.Longhin (4), M. Mezzetto(5), M.T. Muciaccia (1), A. Paoloni (4), L. Patrizii (2), S. Simone (1), M. Sioli (2,3), G. Sirri (2), M. Spurio (2,3), L. Stanco* (5)

(1) Bari University and INFN(2) INFN Bologna(3) Bologna University(4) INFN-LNF(5) INFN Padova(6)Padova University

* contact

E313

2

Page 3: An Experimental EXERCISE  on European Sterility

SPECTROMETER(S) Prospects for a CERN-PS Experiment

E313

1. Physics

2. Place

3. Setup

1. Analysis

2. Achievements

3

Page 4: An Experimental EXERCISE  on European Sterility

4

What OscillationS between Which ?

E313 PHYSICS

E.G. take the 3+2 model by Kopp et al. (see also Schwetz-Mezzetto talks)

APPEARANCE DISAPPEARANCE DISAPPEARANCE

νμ ⇒ νe

νe ⇒ ν e

νμ ⇒ νμ

TO BE FOLDED with the νμ , νe , νμ , νe BEAM compositions/contaminations

and with ν and ν cross-sections !

Page 5: An Experimental EXERCISE  on European Sterility

3.75*1020 p.o.t = 3 years of anti-ν

E313 PHYSICS-I

5

FluxPS (ν μ ) × Cross − Section

Ratio :

Flux (ν μ ) × σ ν

Flux (ν μ ) × σ ν

3 !

ν μ

νμ

ν /ν

inte

nsi

ties

Pdisappearance (ν μ → ν μ )from previous model

2.5*1020 p.o.t = 2 years of ν

1 RUN = MANY DATA !

Page 6: An Experimental EXERCISE  on European Sterility

E313 PHYSICS-II

The large number of models (i.e. the lack of conclusive DATA)implies the ABSOLUTE need for a DOUBLE measure: FAR and NEAR

to establish what is oscillating and what is not

TWO SPECTROMETERS

FARNEAR

6

at PS site

Page 7: An Experimental EXERCISE  on European Sterility

E313 PHYSICS-III

Charge and momentum measurements in Neutrino Interactionsfor the Charge Current mode: important and challenging

Important because:

• increase the active target mass by measuring the muon momentum• increase the range of m2 (at higher values, especially in the eV2 range)• calibration of the beam with a clean muon measurement at high p• normalization point for the NC/CC rates

• clean separation of nu and anti-nu interactions• disentangle the nu and anti-nu reverse contaminations in the beams

Challenging because:

• find best compromise between passive and active materials

7

Page 8: An Experimental EXERCISE  on European Sterility

E313 PLACEFor semplicity take the T600 LAr proposal *(Memorandum to SPSC09/03/2011)

SpectrometerThe Target coveragemust be as large as possible

FAR site

* Liquid Argon is the best option as for - backgrounds - energy range - full measure of ν interaction

8

Page 9: An Experimental EXERCISE  on European Sterility

E313 PLACE-II NEAR site

Spectrometer

Same Spectrometer, only half shorterin the transverse coordinate

Same Proposal: Liquid Argon is the best optionas for - systematics control - backgrounds - full measure of ν interaction

(Scintillator back-up solution ??)

9

Page 10: An Experimental EXERCISE  on European Sterility

E313 SET-UP(which Spectrometers ?)

Neutrinos

MUONS from CCA.U

.

MUONS in LAr interactions (standard GENIE simulation)

10

Negative Focussing rather different !

Page 11: An Experimental EXERCISE  on European Sterility

E313 SETUP-II

MUONS coming out downstream of LAr

ANGULAR distribution

MOMENTUM distribution

1 rad

4 GeV

11

z-vertex

FAR site

Page 12: An Experimental EXERCISE  on European Sterility

E313 SETUP-III

In conclusion:

• “light” spectrometer, e.g. 2.5 cm iron slabs• several detection layers, e.g. 8 layers per arm• as wide as possible, e.g. 2*8 m (w) * 5 m (h)

Use RPC detectors ALAOP and Precision Trackers

8 m 8 m

5 m

2 m (2 arms)

FAR = 2 * NEAR

12

Dipole with B=1.5 Tesla

Page 13: An Experimental EXERCISE  on European Sterility

E313 Analysis

1

2

5

3

4 3+4+5 collected3+4 p from range4+5 p and q from bending

13

Several topologies to be taken into account (CC mode):

Parametrized simulation and reconstruction of LAr target.Full simulation of Spectrometers’ responses

Page 14: An Experimental EXERCISE  on European Sterility

E313 Analysis-II NEAR site

μ fully contained

Collected by Spectrometer

14

Page 15: An Experimental EXERCISE  on European Sterility

E313 Analysis-III FAR site

15

Collected by Spectrometer

μ fully contained

Page 16: An Experimental EXERCISE  on European Sterility

E313 Achievements-I

- The Charge Identification is better than 98.5% up to ~ 5 GeV momentum- p/p has to be optimized depending on B*dl, no. of planes of measurements and the Iron slab thickness- The containment is dominated by transverse dimensions (!)

16

E.G. Momentum Resolution of largest sample

(full crossing)

Page 17: An Experimental EXERCISE  on European Sterility

E313 Achievements-II

17

3.75x1020 pot

νμ-bar interactions

Reconstructed Neutrino Energy

NEAR site

Reconstructed in LAr

LAr + Spectrometer

νμ-bar LAr+Spect (Q)

νμ LAr+Spect (Q)

Page 18: An Experimental EXERCISE  on European Sterility

18

E313 Achievements-IIbisNEAR site

νμ-bar LAr+Spect (Q)

νμ LAr+Spect (Q)

Reconstructed Neutrino Energy

Page 19: An Experimental EXERCISE  on European Sterility

E313 Achievements-III

19

3.75x1020 pot

Reconstructed Neutrino Energy

FAR site

νμ-bar interactions

Reconstructed in LAr

LAr + Spectrometer

νμ-bar LAr+Spect (Q)

νμ LAr+Spect (Q)

Page 20: An Experimental EXERCISE  on European Sterility

20

E313 Achievements-IIIbis

Reconstructed Neutrino Energy

FAR site

νμ-bar LAr+Spect (Q)

νμ LAr+Spect (Q)

Page 21: An Experimental EXERCISE  on European Sterility

There is great INTEREST in the PHYSICS of the Sterile Neutrinos

(“There is a great confusion under the sky,Then the situation could indeed be excellent”)

E313

Well prompted PHYSICISTS made an Exercise

The PS-CERN option seems to match manyQUESTIONS on the subject of Sterile Neutrinos

The use of Spectrometers (FAR and NEAR)can be a very important handle (if not mandatory)

Conclusions

21

Page 22: An Experimental EXERCISE  on European Sterility

Backup Slides

E313

22

Page 23: An Experimental EXERCISE  on European Sterility

Neutrino energy reconstruction• Muon momentum reconstruction:

– If contained in LAr range– If not contained in LAr and not crossing the spectro

and distance(LAr)>2m MCS– If stop in Arm1 range– If stop in Arm2 range (and charge from bending in Arm1)– If cross Arm1 & Arm2 Bending (charge and momentum)

+ MCS in LAr

• Neutrino energy reconstruction:– If QE: two-body kinematics– If not-QE: gaussian smearing on the

hadronic component E/E = 0.3/sqrt(E)

23

E313

Page 24: An Experimental EXERCISE  on European Sterility

24

E313 Analysis-II NEAR site

μ fully contained

Collected by Spectrometer

Vertex Interaction in Fiducial Volume 100%

“ & μ-track in LAr > 20 cm 89%

“ & “ & escape from LAr 55% μ Partiall ycontained

“ & “ & Spectrometer(with distance in LAr < 2 m)

34%(17%)

collected by Spectr.

“ & “ & stop in arm1 9% stopping in 1rst arm

“ & “ & stop in arm2 7% stopping in 2nd arm

“ & “ & passing through 18% passing through

24

Page 25: An Experimental EXERCISE  on European Sterility

25

E313 Analysis-III FAR siteVertex Interaction in Fiducial Volume 100%

“ & μ-track in LAr > 20 cm 92%

“ & “ & escape from LAr 51% μ partially contained

“ & “ & Spectrometer(with distance in LAr < 2 m)

20%(9%)

collected by Spectr.

“ & “ & stop in arm1 4% stopping in 1rst arm

“ & “ & stop in arm2 5% stopping in 2nd arm

“ & “ & passing through 11% Passing through

25

Collected by Spectrometer

μ fully contained