an pe. intellectual property which belongs to allen … · # 13259 1 story single family residence...

1
Xantrex XW Power Distribution Panel Listing: UL 1741 Xantrex XW Hybrid Inverter/Charger Listing: UL 1741 Xantrex XW Conduit Box Xantrex Solar Charger Controller XW-MPPT60-150 Listing: UL 1741 #1 #2 Xantrex Solar Charger Controller XW-MPPT60-150 Listing: UL 1741 60 IN 60 OUT 6V 48V - + 6V 6V - + 6V 6V - + 6V 6V - + 6V - + - + - + - + - + 100 Amp 120/240 v 12 1P MLO Existing House Panel Renewable Energy N N GND 5. 6. 7. project represented in this document shall comply with the manufacturer's recomendations/specifications and all codes, The electrical contractor shall seal all penetrations resulting from the electrical scope of work. 3. 4. 2. All signage shall be provided as required by the NEC 2008 ed. statutes, and standards adopted by the State and Local Authority Having Jurisdiction. Electrical Notes: shall be installed in the panel location farthest from the panel main lugs. All aspects of the electrical work required to complete the 1. The 2 pole breaker, proposed in the existing house panel, exempted from requirement by law, for Tier 1 Renewable Energy Systems, per Florida Administration Code 25- 6.065(6)(a). Auxilliary disconnects are a utility Co. option. If required by the utility Co., the utility Co., An AC disconnect, at the electrical service entrance, is All raceways, cables, and J-Boxes shall be located under the proposed PV panels/rack. The raceways, from the combiner, shall exit through shall bear the additional expense incurred, as stipulated by the Florida Administration Code. the bottom of the combiner, penetrate the roof and be routed within the building to the XW system. Type 4 mc cable w/#10 USE-2, (typ) 4/0 battery cables, manufacturer provided (typ of 2) Panel N GND + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - Combiner Existing Feed 150 Amp MCB New Double Barreled Lugs feeders and Xantrex conductors are to be connected as shown. 8. Existing main lugs, in 150 Amp MCB House Panel, are to be replaced with double barreled lugs. Existing 3 #6 THWN-2 & #8 eg in 3/4" Emt 2 #4 THWN-2 & #8 eg in 3/4" Emt 3 #8 THWN-2 in 1/2" EMT to be routed through attic space. AUTRY 5KW EXISTING ROOF TRUSS, TOP CHORD OEM HOLD DOWN: 3/8" LAG BOLT OR J- BOLT (HOOKS TRUSS) APPROVED RACKING EXIST. FLAT OR BARREL TILE APPROVED RACKING 1" DIA. SPACER W/ WATERPROOF SEALANT 1" DIA. SPACER, LENGTH ADJUST FLUSH W/ TOP OF TILE WHERE APPLICABLE FILL CAVITY UNDER TILE W/ EXPANSION CONST. FOAM EXISTING MEMBRANE FPL METER GARAGE LAUNDRY EXIST. GENERATOR IN GARAGE EXIST. HOUSE PANEL # 13259 1 STORY SINGLE FAMILY RESIDENCE PROPERTY LINE SHEET NO: PUBLISHED: SHEET NAME: DRAWN: CHECKED: SB AG COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE THIS PLAN AND ITS USE ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENTS COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT). EJCDC C-700 MAY BE REVIEWED AT THE FOLLOWING HYPERLINK: HTTP://WWW.DOUGLASAZ.GOV/PUBLICWORKS/DOCUMENTS/RFP/SEWER_REHAB_PHASE_I/00700%20-%20EJCDC.PDF REVISIONS: THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL. THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS. EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN. ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE AND NATIONAL ELECTRICAL CODE. INSTALLATION OF A SOLAR ELECTRIC SYSTEM 13259 SW 43 ST DAVIE FL 33330 ROOF MOUNT DESIGNED PER: ASCE 7-05, NEC 2008 APPLICABLE CODE: FLORIDA BUILDING CODE 2007 W/09 SUPP. FLORIDA ELEC. CODE 2007 W/09 SUPP. EXPOSURE: WIND LOAD: BLDG. IP. CATEGORY: 140 MPH B II CONTRACTOR: LIC# CVC05664 LIC# CWC043077 2431 CRYSTAL DRIVE FT. MYERS, FL 33907 PH. 239.939.7446 FAX: 239.939.2946 05 SCALE: N.T.S. PV WIRING / SCHEMATIC THIS PLAN IS ONLINE FOR REVIEW @: ELECTRICAL ENGINEERING CONSULTANT: BRUCE A. TOZIER, P.E. LIC # 67336 TOZIER ENGINEERING, INC. 209 S. GLEN ARVEN AVE. TEMPLE TERRACE, FL 33617 OFF. (813) 988-3578 CELL (813) 951-4727 FAX (813) 988-3578 07 SCALE: 1" = 40' ELECTRICAL SYSTEM CALCULATIONS 10 FOR TILE ROOF ATTACHMENT SAMPLE ROOF TILE INSTALLLATION 08 SCALE: NTS SCHEMATIC ROOF LAYOUT 09 SCALE: N.T.S. REQ. SAFETY SIGNAGE I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE THE FIG. 05 ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL. 02 SCALE: N.T.S. ROOF INSTALLATION LOCATION 03 SCALE: N.T.S. PARCEL - SATELLITE PHOTO 01 SCALE: N.T.S. INSTALLATION NOTES PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES: THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN @ WWW.GEZELMANPE.COM/PV/0046_AUTRY_DAVIE_FL.PDF . ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED IN FIGURE 05. THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 3/8TH INCH DIAMETER CORROSION RESISTANT STEEL. THESE HOLD-DOWNS MAY BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOP CORD OF TRUSSES OR BLOCKING OR APPROVED ALTERNATE ANCHOR. APPROVED ANCHORS INCLUDE: LAGS INTO TOP CORD OF TRUSSES OR BLOCKING (MIN 4”X4”X9”) J-BOLTS HOOKING TRUSSES OR BLOCKING ALL THREAD ROD THRU BLOCKING CENTER-TO CENTER ANCHOR SPACING ON EACH LENGTH SPECIFIED MOUNTING RACK SHALL BE 24-INCHES IN PZ-3 (ASCE7 DEFINED -PRESSURE ZONE), 48-INCHES IN PZ2 AND 72-INCHES IN PZ1. THERE SHALL BE TWO PIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. WIND CALCULATIONS MAY BE VIEWED BY OPENING THE FOLLOWING LINK: HTTP://WWW.GEZELMANPE.COM/REFERENCE/AG/WINDUPLIFTCALCS.PDF THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED IN FIGURE 05. THE PV MODULES MAY BE ORIENTED HORIZONTALLY OR VERTICALLY AT THE CONTRACTOR'S OPTION. WIRING SHALL BE AS SHOWN IN FIGURE 05. ALL CONTRACTOR AC & DC WIRING SHALL USE MINIMUM 10 AWG COPPER OEM WIRING AND HARNESSES, REGARDLESS OF WIRE SIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS. THIS PV SYSTEM CONTAINS BATTERIES. OWNER & CONTRACTOR ARE CAUTIONED TO ENSURE THAT BATTERY AND INVERTER/CHARGE CONTROLLER INSTALLATION, MAINTENANCE, AND OPERATING INSTRUCTIONS ARE FOLLOWED. THESE MAY BE VIEW AT: CONCORDE BATTERY@ HTTP://WWW.SUNXTENDER.COM/XTENDER_MAIN.PHP ; XANTREX INVERTER/CHARGE CONTROLLER @ HTTP://WWW.XANTREX.COM/WEB/ID/246/P/DOCS/PT/25/PRODUCT.ASP PV-MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO SUNLIGHT. USE CAUTION & GOOD SENSE TWISTED (WIRE NUT) CONNECTIONS ARE NOT PERMITTED FOR DC WIRING. USE OEM PLUG CONNECTOR HARNESS BETWEEN PV MODULES. MAKE SOLID MECHANICAL CONNECTIONS TO ENSURE ELECTRICAL CONDUCTIVITY BETWEEN ALL PV MODULE ENCLOSURES AND FRAMING MEMBERS WITH NO ELECTRICALLY ISOLATED COMPONENTS, USE #10 AWG BARE COPPER WITH SCREWED CONNECTIONS FOR BONDING JUMPERS AS NEEDED. OEM APPROVED BONDING/GROUNDING DEVICES ARE AN ACCEPTABLE SUBSTITUTE WHEN INSTALLED PER OEM INSTRUCTIONS. DO NOT LEAVE LOOSE, UNSECURED WIRES/HARNESS BETWEEN PV-MODULES, TIE TO THE MOUNTING RAILS WITH UV RESISTANT ZIP TIES, APPROVED WIRE CLIPS OR WIRING TROUGH IN NEAT, PROFESSIONAL MANNER. USE APPROVED MEANS AND METHODS PER NEC CURRENT IN THE JURISDICTION (AND ANY APPLICABLE STATE/LOCAL AHJ AMENDMENTS THERETO). ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS. ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND AS THE SYSTEM “AGES”. INSTALLATION LOCATION INSTALLATION LOCATION 06 SCALE: NTS, SEE COMPLETE OEM AT: http://us.sanyo.com/Solar/Downloads NAME PV- MODULES - 200 W FSEC CERTIFICATION#: PV MODULE: http://www.fsec.ucf.edu/en/industry/testing/PVmodules/certified_modules/detail_sanyo.htm SANYO- HIP-210NKHA SY09-NT90-0232 [email protected] [email protected] [email protected] GEZELMANPE.COM STRUCTURAL : GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN _ PSF WIND FORCES: ASCE 7 PRESSURE ZONE DIAGRAM (PAGE 5 AT 1ST LINK) MAY BE VIEWED AT THE FOLLOWING LINKS: http://www.unirac.com/pdf/ii227.pdf http://www.unirac.com/pdf/ii206.pdf 3 PZ1 -28.9; PZ2 - 41.8; PZ3 - 62.9 OWNER: 13259 SW 43 ST DAVIE FL 33330 AUTRY,THOMAS & LORI AHJ: LEGAL DESCRIPTION: PARCEL ID: 5040 26 07 0310 IMAGINATION FARMS EAST 164-23 B POR PAR A DESC AS COMM SE COR OF SAID PLAT,NW 564.85,W 1687.76 TO POB;SWLY 66.59 TO P/R/C/,SWLY 39.94,SW 54.37,N 292.05,E 136.25 S 244.19 TO POB AKA: LOT 31 PASADENA ESTATES AT IMAGINATION FARMS MINIMUM AC & DC WIRING SIZE #10 AWG COPPER (OEM WIRING & HARNESS EXCLUDED) 04 SCALE: NTS, WWW.UNIRAC.COM/TECHNICAL-SUPPORT/SOLARMOUNT/INSTALL.PHP MOUNTING SYSTEM- UNIRAC.COM SERRATED L ROOF MOUNT UNIRAC SOLAR MOUNT RACK SOLAR MOUNT RAIL BOOTM MOUNT DIAGRAM TOP MOUNT DIAGRAM http://www.unirac.com/pdf/cc-sm-florida.pdf WWW.UNIRAC.COM/TECHNICAL-SUPPORT/SOLARMOUNT/INSTALL.PHP UNIRAC CODE COMPLIANT LETTER - FLORIDA: ”ALTERNATE: CONTRACTOR MAY USE UNIRAC TILE HOOKS. USE TILE HOOK SPACING CHART PAGE 4, OF TILE ROOF HOOK INSTALLATION MANUAL @: HTTP://WWW.UNIRAC.COM/PDF/TH-INSTALL.PDF INTERPOLATION IS AUTHORIZED BETWEEN WIND SPEEDS. USE ZERO SNOW LOAD COLUMN” SCALE: 1-1/2" = 1'-0" TILE MOUNTING DETAIL

Upload: others

Post on 11-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AN PE. INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN … · # 13259 1 story single family residence property line sheet no: published: sheet name: drawn: sb agchecked: copy right &

XantrexXW Power Distribution PanelListing: UL 1741

Xantrex XW HybridInverter/ChargerListing: UL 1741

XantrexXW Conduit Box

Xa

ntr

ex

So

lar

Ch

arg

er

Co

ntr

olle

rX

W-M

PP

T6

0-1

50

List

ing

: U

L 1

74

1

#1

#2

Xa

ntr

ex

So

lar

Ch

arg

er

Co

ntr

olle

rX

W-M

PP

T6

0-1

50

List

ing

: U

L 1

74

1

60IN

60OUT

6V

48V

-+

6V

6V

-+

6V

6V

-+

6V

6V

-+

6V

-+

-+

-+

-+

- +

100 Amp120/240 v

12 1PMLO

Existing

House Panel

RenewableEnergy

N

N

GND

5.

6.

7.

project represented in this document shall comply with the

manufacturer's recomendations/specifications and all codes,

The electrical contractor shall seal all penetrations resulting

from the electrical scope of work.

3.

4.

2.

All signage shall be provided as required by the NEC 2008 ed.

statutes, and standards adopted by the State and Local

Authority Having Jurisdiction.

Electrical Notes:

shall be installed in the panel location farthest from the

panel main lugs.

All aspects of the electrical work required to complete the 1.

The 2 pole breaker, proposed in the existing house panel,

exempted from requirement by law, for Tier 1 Renewable

Energy Systems, per Florida Administration Code 25-

6.065(6)(a). Auxilliary disconnects are a utility Co.

option. If required by the utility Co., the utility Co.,

An AC disconnect, at the electrical service entrance, is

All raceways, cables, and J-Boxes shall be located

under the proposed PV panels/rack.

The raceways, from the combiner, shall exit through

shall bear the additional expense incurred, as

stipulated by the Florida Administration Code.

the bottom of the combiner, penetrate the roof and

be routed within the building to the XW system.

Type 4 mc cable w/#10 USE-2, (typ)

4/0 battery cables, manufacturer provided

(typ of 2)

Panel

N

GND

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

+ -

Combiner

Existing Feed

150 AmpMCB

New DoubleBarreled Lugs

feeders and Xantrex conductors are to be connected

as shown.

8. Existing main lugs, in 150 Amp MCB House Panel,

are to be replaced with double barreled lugs. Existing

3 #6 THWN-2 & #8 eg in 3/4" Emt

2 #4 THWN-2 & #8 eg in 3/4" Emt

3 #8 THWN-2 in 1/2" EMT to be routed through attic space.

AUTRY 5KW

EXISTING ROOF TRUSS,TOP CHORD

OEM HOLD DOWN:

3/8" LAG BOLT OR J- BOLT (HOOKS TRUSS)

APPROVED RACKING

EXIST. FLAT OR BARREL TILE

APPROVED RACKING

1" DIA. SPACER

W/ WATERPROOF SEALANT

1" DIA. SPACER, LENGTH

ADJUST FLUSH W/ TOP OF TILE

WHERE APPLICABLEFILL CAVITY UNDER TILE

W/ EXPANSION CONST. FOAM EXISTING MEMBRANE

FPL METER

GARAGE

LAUNDRY

EXIST. GENERATORIN GARAGE

EXIST. HOUSE PANEL

# 13259 1 STORYSINGLE FAMILY RESIDENCE

PR

OP

ER

TY

LIN

E

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

THIS PLAN AND ITS USE ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINTCONSTRUCTION DOCUMENTS COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTIONCONTRACT). EJCDC C-700 MAY BE REVIEWED AT THE FOLLOWING HYPERLINK:

HTTP://WWW.DOUGLASAZ.GOV/PUBLICWORKS/DOCUMENTS/RFP/SEWER_REHAB_PHASE_I/00700%20-%20EJCDC.PDF

REVISIONS:

THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL.THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS.EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN.

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEREQUIREMENTS OF THE CURRENTFLORIDA BUILDING CODE ANDNATIONAL ELECTRICAL CODE.

INS

TA

LLA

TIO

N O

F A

SO

LAR

ELE

CT

RIC

SY

ST

EM

13

25

9 S

W 4

3 S

T D

AV

IE F

L 3

33

30

RO

OF

MO

UN

T

DESIGNED PER: ASCE 7-05, NEC 2008

APPLICABLE CODE:

FLORIDA BUILDING CODE 2007 W/09 SUPP.

FLORIDA ELEC. CODE 2007 W/09 SUPP.

EXPOSURE:

WIND LOAD:

BLDG. IP. CATEGORY:

140 MPHB

II

CONTRACTOR:

LIC# CVC05664 LIC#CWC043077

2431 CRYSTAL DRIVEFT. MYERS, FL 33907

PH. 239.939.7446FAX: 239.939.2946

05SCALE: N.T.S.

PV WIRING / SCHEMATIC

THIS PLAN IS ONLINE FOR REVIEW @:

ELECTRICAL ENGINEERING

CONSULTANT:

BRUCE A. TOZIER, P.E.

LIC # 67336

TOZIER ENGINEERING, INC.

209 S. GLEN ARVEN AVE.

TEMPLE TERRACE, FL 33617

OFF. (813) 988-3578

CELL (813) 951-4727

FAX (813) 988-3578

07SCALE: 1" = 40'

ELECTRICAL SYSTEM CALCULATIONS

10FOR TILE ROOF ATTACHMENT

SAMPLE ROOF TILE INSTALLLATION

08SCALE: NTS

SCHEMATIC ROOF LAYOUT

09SCALE: N.T.S.

REQ. SAFETY SIGNAGE

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.

ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODETHE FIG. 05 ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER,

REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

02SCALE: N.T.S.

ROOF INSTALLATION LOCATION03

SCALE: N.T.S.

PARCEL - SATELLITE PHOTO01

SCALE: N.T.S.

INSTALLATION NOTES

PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES:

THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE

ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN @ WWW.GEZELMANPE.COM/PV/0046_AUTRY_DAVIE_FL.PDF . ACTIVE HYPERLINKS ON EV PROVIDE EASYACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A

CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL.

THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR MODULES

SHALL BE THE NUMBER, MAKE AND MODEL LISTED IN FIGURE 05. THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 3/8TH INCH DIAMETER CORROSION RESISTANT STEEL.THESE HOLD-DOWNS MAY BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOP CORD OF TRUSSES OR BLOCKING OR APPROVED ALTERNATE ANCHOR. APPROVEDANCHORS INCLUDE:

• LAGS INTO TOP CORD OF TRUSSES OR BLOCKING (MIN 4”X4”X9”)• J-BOLTS HOOKING TRUSSES OR BLOCKING• ALL THREAD ROD THRU BLOCKING

CENTER-TO CENTER ANCHOR SPACING ON EACH LENGTH SPECIFIED MOUNTING RACK SHALL BE 24-INCHES IN PZ-3 (ASCE7 DEFINED -PRESSURE ZONE), 48-INCHES IN PZ2 AND72-INCHES IN PZ1. THERE SHALL BE TWO PIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. WIND CALCULATIONS MAY BE VIEWED BY OPENING THE FOLLOWING LINK:

HTTP://WWW.GEZELMANPE.COM/REFERENCE/AG/WINDUPLIFTCALCS.PDF

THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED IN FIGURE 05. THE PVMODULES MAY BE ORIENTED HORIZONTALLY OR VERTICALLY AT THE CONTRACTOR'S OPTION.

WIRING SHALL BE AS SHOWN IN FIGURE 05. ALL CONTRACTOR AC & DC WIRING SHALL USE MINIMUM 10 AWG COPPER OEM WIRING AND HARNESSES, REGARDLESS OF WIRESIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS.

THIS PV SYSTEM CONTAINS BATTERIES. OWNER & CONTRACTOR ARE CAUTIONED TO ENSURE THAT BATTERY AND INVERTER/CHARGE CONTROLLER INSTALLATION,

MAINTENANCE, AND OPERATING INSTRUCTIONS ARE FOLLOWED. THESE MAY BE VIEW AT: CONCORDE BATTERY@ HTTP://WWW.SUNXTENDER.COM/XTENDER_MAIN.PHP ;

XANTREX INVERTER/CHARGE CONTROLLER @ HTTP://WWW.XANTREX.COM/WEB/ID/246/P/DOCS/PT/25/PRODUCT.ASP

• PV-MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO SUNLIGHT. USE CAUTION & GOOD SENSE

• TWISTED (WIRE NUT) CONNECTIONS ARE NOT PERMITTED FOR DC WIRING. USE OEM PLUG CONNECTOR HARNESS BETWEEN PV MODULES.• MAKE SOLID MECHANICAL CONNECTIONS TO ENSURE ELECTRICAL CONDUCTIVITY BETWEEN ALL PV MODULE ENCLOSURES AND FRAMING MEMBERS WITH NO

ELECTRICALLY ISOLATED COMPONENTS, USE #10 AWG BARE COPPER WITH SCREWED CONNECTIONS FOR BONDING JUMPERS AS NEEDED. OEM APPROVED

BONDING/GROUNDING DEVICES ARE AN ACCEPTABLE SUBSTITUTE WHEN INSTALLED PER OEM INSTRUCTIONS.

• DO NOT LEAVE LOOSE, UNSECURED WIRES/HARNESS BETWEEN PV-MODULES, TIE TO THE MOUNTING RAILS WITH UV RESISTANT ZIP TIES, APPROVED WIRE CLIPS ORWIRING TROUGH IN NEAT, PROFESSIONAL MANNER.

• USE APPROVED MEANS AND METHODS PER NEC CURRENT IN THE JURISDICTION (AND ANY APPLICABLE STATE/LOCAL AHJ AMENDMENTS THERETO).• ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS.

• ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND AS THE SYSTEM “AGES”.

INSTALLATION LOCATIONINSTALLATION LOCATION

06SCALE: NTS, SEE COMPLETE OEM AT: http://us.sanyo.com/Solar/Downloads

NAME PV- MODULES - 200 W

FSEC CERTIFICATION#:PV MODULE:http://www.fsec.ucf.edu/en/industry/testing/PVmodules/certified_modules/detail_sanyo.htm

SANYO- HIP-210NKHA

SY09-NT90-0232

BT

OIZ

ER

@E

AR

TH

LIN

K.N

ET

ALL

EN

@G

EZ

ELM

AN

PE

.CO

MS

IGG

I@C

AD

VIC

E.U

S

GE

ZE

LMA

NP

E.C

OM

STRUCTURAL: GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN _ PSFWIND FORCES:

ASCE 7 PRESSURE ZONE DIAGRAM (PAGE 5 AT 1ST LINK) MAY BE VIEWED AT THE FOLLOWING LINKS:

http://www.unirac.com/pdf/ii227.pdf http://www.unirac.com/pdf/ii206.pdf

3PZ1 -28.9; PZ2 - 41.8; PZ3 - 62.9

OWNER:

13259 SW 43 ST DAVIE FL 33330

AUTRY,THOMAS & LORI

AHJ:LEGAL DESCRIPTION:PARCEL ID: 5040 26 07 0310

IMAGINATION FARMS EAST 164-23 B POR PAR A DESC AS COMM SE COR OF SAID

PLAT,NW 564.85,W 1687.76 TO POB;SWLY 66.59 TO P/R/C/,SWLY 39.94,SW 54.37,N 292.05,E 136.25 S 244.19 TO POB AKA:LOT 31 PASADENA ESTATES AT IMAGINATION FARMS

MINIMUM AC & DC WIRING SIZE #10 AWG

COPPER

(OEM WIRING & HARNESS EXCLUDED)04SCALE: NTS, WWW.UNIRAC.COM/TECHNICAL-SUPPORT/SOLARMOUNT/INSTALL.PHP

MOUNTING SYSTEM- UNIRAC.COM

SERRATED L ROOF MOUNT UNIRAC SOLAR MOUNT RACKSOLAR MOUNT RAIL

BOOTM MOUNT DIAGRAM TOP MOUNT DIAGRAM

http://www.unirac.com/pdf/cc-sm-florida.pdf

WWW.UNIRAC.COM/TECHNICAL-SUPPORT/SOLARMOUNT/INSTALL.PHP

UNIRAC CODE COMPLIANT LETTER - FLORIDA:

”ALTERNATE:CONTRACTOR MAY USE UNIRAC TILE HOOKS.USE TILE HOOK SPACING CHART PAGE 4, OF TILE ROOF HOOKINSTALLATION MANUAL @:

HTTP://WWW.UNIRAC.COM/PDF/TH-INSTALL.PDF

INTERPOLATION IS AUTHORIZED BETWEEN WIND SPEEDS.USE ZERO SNOW LOAD COLUMN”

SCALE: 1-1/2" = 1'-0"

TILE MOUNTING DETAIL

dv8230us
Released