All aspects of the electrical work required to complete the
project represented in this document shall comply with the
manufacturer's recomendations/specifications and all codes,
The electrical contractor shall seal all penetrations resulting
from the electrical scope of work.
3.
4.
2.
Electrical Notes:
All signage shall be provided as required by the NEC 2008 ed.
5.
1.
statutes, and standards adopted by the State and Local
Authority Having Jurisdiction.
An AC disconnect, at the electrical service entrance, is exempted
from requirement by law, for Tier 1 renewable Energy Systems,
per Florida Administration Code 25-6.065(6)(a). Auxilliary
disconnects are a utility Co. option. If required by the utility Co.,
the utility Co. shall bear the additional expense incurred, as
stipulated by the Florida Administration Code.
A8B7
+ - + - + - + - + -+ -
+ - + -
+ - + -
w/#10 USE-2 (typ)
+ - + -+ - + -+ -
+ -+ - + - + - + -
+ - + - + - + -+ - + -
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
Kyocera 210 W
+ -
L1 L2 N GND
SMA SB5000US
A1 A2 A3 A4 A5 A6 A7
B1B2B3B4B5B6
B8
A9A10A11A12A13
B9 B10 B11 B12 B13
Existing 100 Amp120/240 v
25
N
GND
Type 4 MC cable
4 #10 THWN-2 &
#10 eg in 1/2 Emt
Roof mounted J-Box
w/#10 USE-2 (typ)
Type 4 MC cable
15 Amp Fuses
All raceways, conductors and J-Boxes shall be located under the
proposed PV panels/rack.`
Raceway from roof mounted J-Box shall exit through the bottom
of the J-Box, penetrate the roof and be routed, within the
building, to the proposed inverter.
6.
The proposed 2 pole backfeed circuit breaker shall be located
as required by NEC 690.64.(B)(7).
7.
Busby 5KW
PROPERTY LINE
1 STORY MET HANGAR
PZ1 - INSTALLATION AREA
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN:
THIS IS A SINGLE SHEET PLAN
CHECKED:SB AG
0041_Busby_PortStLucie_FL.dwg
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S I
NT
ELL
EC
TU
AL
PR
OP
ER
TY
WH
ICH
BE
LON
GS
TO
ALL
EN
GE
ZE
LMA
N P
E.
•A
CC
ES
S I
S G
IVE
N T
O T
HE
IN
FO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H I
T I
S I
NT
EN
DE
D.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ES
S,
WR
ITT
EN,
PE
RM
ISS
ION
OF
ALL
EN
GE
ZE
LMA
N P
E
11/5/2009 8:51:58 PM
08SCALE: 1" = 40'
ELECTRICAL SYSTEM NOTES05
SCALE: N.T.S.
PV WIRING / SCHEMATIC
02SCALE: N.T.S.
AERIAL PHOTOGRAPH- SITE PLAN03
SCALE: N.T.S.
PHOTO FROM WEST SIDE01
SCALE: N.T.S.
INSTALLATION NOTES
04SCALE: 1/8" = 1'-0"
MOUNTING SYSTEM- HDG UNISTRUT
07SCALE: NTS
SAMPLE INSTALLATION PHOTO
06http://www.kyocerasolar.com/pdf/specsheets/KYOCERA-KD210GX-LPU.pdf
KYOCERA PV- MODULES - 210 W
09SCALE: 1/16" = 1'-0"
EQUIPMENT LAYOUT
EN
LAR
GE
D V
IEW
ING
& H
YP
ER
LIN
KS
:P
RIN
T V
ER
SIO
N O
F T
HIS
PLA
N P
RO
VID
ES
MIN
IMU
M I
NF
OR
MA
TIO
N N
EE
DE
D B
Y U
SE
RS
.
ELE
CT
RO
NIC
VE
RS
ION
(E
V)
PR
OV
IDE
S M
AG
NIF
IED
VIE
WIN
G U
P T
O 6
40
0%
. E
V A
LSO
PR
OV
IDE
S H
YP
ER
LIN
K A
CC
ES
S T
O O
EM
MA
NU
ALS
AN
D A
BU
ND
AN
T O
TH
ER
SU
PP
LEM
EN
TA
RY
IN
FO
RM
AT
ION
.EV
MA
Y B
E A
CC
ES
SE
D A
T:
WW
W.G
EZ
ELM
AN
PE
.CO
M/P
V/0
04
1_
Bu
sby_
Po
rtS
tLuci
e_F
L.d
wg
ENLARGED VIEWING & HYPERLINKS:PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS.
ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS ANDABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT:
WWW.GEZELMANPE.COM/PV/0041_Busby_PortStLucie_FL.dwg
BUSBY PV INSTALLATION NOTES:
THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS.
USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN WWW.GEZELMANPE.COM/PV/0041_BUSBY_PORTSTLUCIE_FL.PDF . ACTIVEHYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT
MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEMDETAIL, OEM SHALL PREVAIL.
THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTO VOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE
SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED IN FIGURE 05. THE HOLD DOWN ANCHORS SHALL BE 1/2- INCH DIAMETER, CORROSIONRESISTANT STEEL BOLTS THRU PURLINS INTO CORROSION RESISTANT UNISTRUT P5500T RACK AS SHOWN IN ACCOMPANYING DRAWINGS.
THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED IN FIGURE05. THE PV MODULES SHALL VERTICAL - “PORTRAIT” ORIENTATION.
WIRING SHALL BE AS SHOWN IN FIGURE 05. ALL CONTRACTOR AC & DC WIRING SHALL USE MINIMUM 10 AWG COPPER OEM WIRING AND HARNESSES,REGARDLESS OF WIRE SIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS.
• PV-MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO SUNLIGHT. KEEP COVERED WITH OPAQUE MATERIAL UNTIL ALL WIRING IS COMPLETED.
• TWISTED (WIRE NUT) CONNECTIONS ARE NOT PERMITTED FOR DC WIRING. USE OEM PLUG CONNECTOR HARNESS BETWEEN PV MODULES.• MAKE SOLID MECHANICAL CONNECTIONS TO ENSURE ELECTRICAL CONDUCTIVITY BETWEEN ALL PV MODULE ENCLOSURES AND FRAMING MEMBERS WITH
NO ELECTRICALLY ISOLATED COMPONENTS, USE #10 AWG BARE COPPER WITH SCREWED CONNECTIONS FOR BONDING JUMPERS AS NEEDED. OEM
APPROVED BONDING/GROUNDING DEVICES ARE AN ACCEPTABLE SUBSTITUTE WHEN INSTALLED PER OEM INSTRUCTIONS.
• DO NOT LEAVE LOOSE, UNSECURED WIRES/HARNESS BETWEEN PV-MODULES, TIE TO THE MOUNTING RAILS WITH UV RESISTANT ZIP TIES, APPROVEDWIRE CLIPS OR WIRING TROUGH IN NEAT, PROFESSIONAL MANNER.
• USE APPROVED MEANS AND METHODS PER NEC CURRENT IN THE JURISDICTION (AND ANY APPLICABLE STATE/LOCAL AHJ AMENDMENTS THERETO).• ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS.• ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND AS THE
SYSTEM “AGES”.
THIS PLAN AND ITS USE ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTIONDOCUMENTS COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) . EJCDC C-700 MAY BE REVIEWED AT THE FOLLOWING HYPERLINK:
HTTP://WWW.DOUGLASAZ.GOV/PUBLICWORKS/DOCUMENTS/RFP/SEWER_REHAB_PHASE_I/00700%20-%20EJCDC.PDF
10SCALE: N.T.S.
REQ. SAFETY SIGNAGE
REFER TO 2007 FLORIDAELECTRICAL CODE FORREQUIRED SIGNAGE OFWHICH THESE AREEXAMPLES
BUZBY 5.0 KW PV SYSTEM NOTES & CALCULATIONS
MODULES: KYOCERA KD210GX-LPU , 210 WATTS X 26 MODULES
MODULE PERFORMANCE CHARACTERISTICS (STC):
MAX. POWER WP = 210 WMAX. POWER VOLTAGEVMPP = 26.6 VMAX. POWER CURRENT IMPP = 7.90 AMPSOPEN CIRCUIT VOLTAGE VOC = 32.2 VSHORT CIRCUIT CURRENT ISC = 8.58 AMPSMAX. SYSTEM VOLTAGE = 600 VSERIES FUSE = 15 AMPSVOC TC = -.12 V/C°ISC TC = 5.15 X 10¯ ³AMPS/C°MAX. FUSE = 15 AMPS
** ALL MEASUREMENTS ARE AT STANDARD TEST CONDITIONS OF1000 WATTS/M2 IRRADIANCE AT 25 DEGREES C **
INVERTERS: SB5000US
MAX INPUT VOLTAGE = 600 VDCOPERATING RANGE = 250 - 600 VDCPV START VOLTAGE = 300 VDC
STRING INFORMATION
STRINGS TOTAL; 2 STRINGS, EACH WITH 13 MODULES CONNECTEDIN SERIES.VOC= 13 MODULES IN SERIES AT 32.2 VOC = 13 X 32.2V = 418.6VDCVMP= 13 MODULES IN SERIES AT 26.6 VMP = 13X 26.6= 345.8 VDCISC= 8.58 AMPS X 2 SOURCE CIRCUITS (A & B) = 17.16 AMPSIMP= 7.90 AMPS X 2 SOURCE CIRCUITS = 15.8 AMPSPOWER = 26 MODULES AT 210 WATTS = 5460 WATTS
MAXIMUM VOLTAGE:
TEMPERATURE CORRECTION FOR CRYSTALLINE MODULESLOWEST RECORDED TEMPERATURE FOR PORT ST LUCIE PERWEATHER.COM 30 DEGREES F.PER NEC 2008-T690.7 MAX SYSTEM VOLTAGE CORRECTIONFACTOR OF 1.1213 PANELS IN SERIES VOC = 418.6 VDC1.12 X 418.6 = 468.83 VDC 468.83 VDC < 600 VDC MAX ALLOWED, PASSED.
MAXIMUM CURRENT:
OVER IRRADIATION:EACH STRING HAS AN ISC OF 8.58 AMPS125% CORRECTION PER NEC 690.8(A)(1)= 8.58 X 1.25=10.725 AMPS
AMPACITY/CONTINUOUS CURRENT:NEC 690.8(B)(1) 10.725 X 1.25 = 13.41 AMPS
NEC TABLE 310.15(B)(2)(A), 4 WIRES CURRENT CARRYING WIRES INCONDUIT DE-RATING TO 80%
VOLTAGE DROP FOR FARTHEST 11 MODULE STRING TO INVERTER:
% VD = 2 (70FT) 1.29OHMS (13.41 AMPS) 100% / ((1000FT) 345.8VDC)
%VD = .7 %
CONDUCTOR AMPACITY #10 THWN-2:
NEC TABLE 310.16 W/CORRECTION FACTOR @ 41 - 45 DEG. C ANDTABLE 310.15(B) (2) (A) 20 W/4 COND.
40 AMPS X .87 X .8 = 27.84 AMPS
REVISIONS:
FSEC CERTIFICATION#: KC09-NT90-0240
PV MODULE KD210GX-LPU
HTTP://WWW.FSEC.UCF.EDU/EN/INDUSTRY/TESTING/PVMODULES/CERTIFIED_MODULES/DETAIL_KYOCERA.HTM
INSTALLATION LOCATION SOUTH ROOFINSTALLATION LOCATION
STRUCTURAL:• GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN 5_PSF• WIND ENGINEERING: 130-MPH WIND ZONE, EXPOSURE CATEGORY C, BUILDING IMPORTANCE CATEGORY II
WIND FORCES: +/- pz1_24.9, pz2_39.9, pz3_57.3
• ASCE 7 PRESSURE ZONE DIAGRAM (PAGE 5 AT 1ST LINK) AND UNIRAC DETAILS MAY BE VIEWED AT THE FOLLOWING HYPERLINKS:
• http://www.unirac.com/pdf/ii227.pdf http://www.unirac.com/pdf/ii206.pdf
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODETHE BELOW ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER,REFER TO OEM LITERATURE WHICH SHALL PREVAIL:
APPLICABLE CODE:FLORIDA BUILDING CODE 2007 W/09 SUPP
FLORIDA ELEC. 2007 CODE W/09 SUPP
DESIGNED PER:ASCE 7-05
NEC 2008
THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL.THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS.EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN.
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM
www.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEREQUIREMENTS OF THE CURRENTFLORIDA BUILDING CODE ANDNATIONAL ELECTRICAL CODE.
ELECTRICAL ENGINEERINGCONSULTANT:
BRUCE A. TOZIER, P.E.LIC # 67336TOZIER ENGINEERING, INC.209 S. GLEN ARVEN AVE.TEMPLE TERRACE, FL 33617OFF. (813) 988-3578CELL (813) 951-4727FAX (813) 988-3578
SCALE: 1-1/2" = 1'-0"
HOLD DOWN DETAIL
OWNER:
JAMES D BUSBY II KRISTINA A BUSBY
18701 KITTY HAWK CT, PORT ST LUCIE FL 34987
LEGAL DESCRIPTION:
PARCEL ID:3215-801-0045-000-5
AERO ACRES BLK 2 LOT 16
(1.223 AC) (OR 1376-2722: 1617-2904)
WIND LOAD:DESIGNED FOR ____ MPH 130
WIND EXPOSURE:CATEGORY _ C
COMPLIANCE: IEEE-929, IEE-1547, UL 1741, UL 1998
MINIMUM AC & DC WIRING SIZE #10 AWG COPPER
(OEM WIRING & HARNESS EXCLUDED)
SMA AMERICA, SB5000US (240V), 5000 WATT GRID
TIED PV INVERTER
SPECIFICATIONS:WWW.SOLARELECTRICSUPPLY.COM/PDF/SUNNY%20BOY/SB5000US-7000US.PDF
SCALE: NTS
EXISTING ROOF/RAMING
OWNER/CONTRACTOR
JAMES D BUSBY
18701 KITTY HAWK CT
PORT ST LUCIE FL 34987
NOTE:INVERTER TO BE LOCATED ADJACENT TO 100 AMP PANEL INSIDE HANGAR.PENETRATE THE ROOF AT THE J-BOX AS SHOWN IN THE PHOTOAND RUN CONDUIT ON THE UNDERSIDE OF THE ROOF
SCALE: NTS
UNISTRUT P5500 T
SCALE: 3/4" = 1'-0"
UNISTRUT LAYOUT DETAIL
SEE DETAIL
SCALE: 6" = 1'-0"
HOLD DOWN DETAIL
2.001.50
1.00
0.75
1.25
Ø0.50
Ø0.25
1
8" THK FLAT STEEL
HOLES FOR PIVOT BOLT-
USED WHEN ANCHORING
ONLY ONE SOLAR PANEL
SOLAR PANEL EACH SIDE
1
8" THK FLAT STEEL
1
8" THK FLAT STEEL
1
4" INDENTURES FOR PIVOT BOLT-
USED WHEN ANCHORING
ONLY ONE SOLAR PANEL
0.75
1.25
Ø0.50
Ø0.25
1
8" THK FLAT STEEL
3.00
INDENTURES FOR PIVOT BOLT-
USED WHEN ANCHORING
ONLY ONE SOLAR PANEL
3.00
S5CLAMP-SUBSTITUE.DWG
11/4/2009 8:14 PM
02SCALE: 1" = 1"
UPPER PLATE ISOMETRIC01
SCALE: 1" = 1"
UPPER PLATE - TOP
04SCALE: 1" = 1"
LOWER PLATE ISOMETRIC03
SCALE: 1" = 1"
LOWER PLATE - TOP
HOLD DOWN BOLT HERE