analyzer-204-o.pdf
TRANSCRIPT
-
The ability to analytically quantify highly reactive volatile organic compounds Oil/VOCs in water is greatly enhancedwith the Sample Transfer StripperTM (Patented Membrane Technology) and the solid state sensor offered by AnalyticalSystems International Keco (ASI KECO). The analyzer system utilizes many patented and exclusive features onlyavailable from ASI KECO.
The principle of operation requires a consistent free flowing liquid sample into a Sample Transfer StripperTM unit thatseparates the VOCs from the oil in the waer. A hydrocarbon free consistently flowing air carrier then sweeps the oil/VOCs in a gaseous form to the solid state sensor for quantitative analysis in ppb w, ppm w, or up to saturation levels.An optional patented liquid validation/calibration by PermTubeTM is available. This unattended on-line analysis iseconomically superior to inaccurate laboratory analyzers where unstable grab samples result in VOCs deteriorationthat produce analytical errors. Downtime is reduced to less than 10% of the El Paso, TOC or Sparger methodsand the economic pay out is increased because of reduced product loss. In one case, 12,000 pounds of productloss per day was quickly identified by this proven and accurate on-line analytical method.
TCEQ letters has designated the Model 204 as Best Available Control Technology and Equivalency forcontinuous monitoring of cooling tower applications.
Applications include analysis of Oil/VOCs in water for cooling towers, heat exchangers, holding ponds, run off water,and waste water and more.
Continuous On-Line Analysis 20+ Years Experience Wide ranges: 1 ppb w, ppm w and
saturation Liquid Validation by PermTube 4-20mA & RS-232/485 No Normal Calibrations Required Proven On-Line Reliability TCEQ Best Available Control Technology Preferred vendor by Shell & Saudi Aramco
Model 204-O
OIL IN WATER ANALYZERCONTINUOUS ON-LINE PROCESS
Features - Patented & Exclusive
Description & Principle of Operation
(281) 516-3950 FAX (281) 351-8925 www.asikeco.com [email protected]
Wastewater Heat Exchanger Cooling Water Holding Ponds Runoff Water Produced WaterShip Bilge Water Dam Sumps Phenol in Water Storm Water
Awarded Shell Global & Saudi AramcoPreferred Vendor
TCEQ Best Available Control Technology
-
MODEL 204 SPECIFICATIONS
Analytical Systems Intl reserves the right to make revisions and or changes without notice. Analytical Systems Intl shall not be liable for any errorsor omissions made or any damages resulting from the use of the analyzer, information, or the manual. 03095 1995 Printed in the United States ofAmerica.
Analyzer Quote Request Form:Analytical Systems International provides design and application engineering assistance for the Users analyzerrequirements. For a quotation, please complete the ASI Analyzer Quote Request Form at www.ASIKECO.com.For a quote request from, see main web page top right orange button.
POWER INPUT110 VAC 50/60 Hz @ 6 Amps.220 VAC 50/60Hz (optional)
TEMPERATUREOven Setting with Automatic ControlOperating: 5C to 50CStorage: 0C to 70CPPB W Range Requires Temp. Control Building
PERFORMANCERange: Customer Specified PPB W thru PPM W to SaturationPrimary Chemical Component Customer SpecifiedResolution: + 1% of Calibrated RangeRepeatability: + 2% of Full Scale
ACCESSORY OPTIONSPrimary Filter, One Liter/min. SweepCabinet Heater & ThermostatSpecial Sampling SystemsPatented Liquid Validation System by Perm TubeTMAir Purifier For Hydrocarbon Free Carrier
MEMORY / COMPUTER INTERFACERS-232/485 Serial Port Communication
DISPLAYAlpha Numeric Large LCD
ANALOG OUTPUT SIGNAL4-20ma Isolated (optional)4-20ma Linearized (standard)
SAMPLE INPUTPressure Regulator & Gauge Provided10 PSIG Minimum @ 20 ml/min. Sample FlowTemperature Control Automatic
UTILITY SUPPLYCarrier: Zero Air or Breathing Quality (Hydrocarbon Free) @ 200 ml/min.Calibration Supply Chemical
ALARM CONTACTS (optional)High and Low Concentration RelayDiagnostic Alarms for Loss of Sample Flow, Air Flow, Purge Flow & Power Loss
AREA CLASSIFICATIONSGeneral Purpose (standard)Type Z Purge Class I Div. II, Gr. B,C,D (optional)Type X Purge Class I Div. I, GR. B,C,D (optional)
CABINET DIMENSIONS & WEIGHTStainless Steel NEMA 4X 36" Hx24" Wx10" D(90cm Hx60cm Wx26cm D) 200 lbs. (91 kgs)
DIGITALDISPLAY
4-20 MAOUTPUT
& ALARMS
FLOWDIAGRAM
PRINTER
CARRIER AIRFLOW CONTROLLER
SAMPLEINPUT
SECONDARYFILTER
SAMPLE SWEEP
INTERFACERS-232/485
3 4
1 2
SAMPLETRANSFERSTRIPPER
(STS)
PRE-HEATEXCHANGER
WASTE SAMPLE20 PSIG MAXIMUM BACKPRESSURE
AIR INPUT HYDRO-CARBON
FREE & BREATHINGQUALITY
FLOW METER
THERMOSTATEDOVEN
REGULATOR& GAUGE
SOLIDSTATE
SENSOR
VENTNO BACKPRESSURE
NEEDLEVALVE
OPTIONAL LIQUID VALIDATIONSYSTEM NOT SHOWN
ELECTRONICMODULE