ankle brachial index why it is essential to measure both arms · 2020-03-04 · product brochure...

9
Ankle Brachial Index Why it is essential to measure both arms Example a) One Arm Example b) Both Arms Right Arm Pressure 110 Right Ankle Pressure 105 Left Ankle Pressure 105 Right Arm Pressure 110 Left Arm Pressure 140 Right Ankle Pressure 105 Left Ankle Pressure 105 105 110 = 0.96 Ankle Brachial Pressure: 105 140 = 0.75 Ankle Brachial Pressure: You would INCORRECTLY compress Otherwise: • You could misdiagnose PAD (Vowden & Vowden; 2018)** • You could apply compression to a patient with PAD which could lead to an adverse incident (Vowden & Vowden; 2018)** • You should always follow evidence based practice • Automatic systems which measure the pressure in only one arm contradict the guidelines and may miss or incorrectly classify cases of PAD. Join the conversation @huntleighdiag #correctABI #2arms For more information contact 029 2048 5885 or visit www.huntleigh-diagnostics.com Huntleigh Healthcare Ltd. 35 Portmanmoor Rd. Cardiff. CF24 5HN * NICE, CG147 (Peripheral arterial disease: diagnosis and management 2018); ESC - European Society of Cardiology (Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery, European Heart Journal, 2017); ACC/AHA - American College of Cardiology/American Heart Association (Guideline on the management of Patients with Lower Extremity Peripheral Artery Disease, Circulation, 2017); Measurement and Interpretation of the Ankle-Brachial Index (Aboyans et al, Circulation, 2012); TASC2 - Inter-Society Consensus for the Management of Peripheral Arterial Disease (Journal Of Vascular Surgery, 2007) ** Vowden P & Vowden K (The importance of accurate methodology in ABPI calculation when assessing lower limb wounds, BJCN, 2018) You would NOT compress soap123 Current guidelines specify you should measure both arm pressures and take the highest. (NICE, ESC, ACC/AHA, TASC2 and Aboyans et al*) Dopplex Ability is an automatic ABI system that correctly measures systolic pressures in all four limbs.

Upload: others

Post on 12-Mar-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

Ankle Brachial IndexWhy it is essential to measure both arms

Example a)One Arm

Example b)Both Arms

Right ArmPressure110

Right AnklePressure105

Left AnklePressure

105

Right ArmPressure110

Left ArmPressure

140

Right AnklePressure105

Left AnklePressure

105

105110

= 0.96Ankle Brachial Pressure: 105140

= 0.75Ankle Brachial Pressure:

You would INCORRECTLY compress

Otherwise:

• You could misdiagnose PAD (Vowden & Vowden; 2018)**

• You could apply compression to a patient with PAD which could lead to an adverse incident (Vowden & Vowden; 2018)**

• You should always follow evidence based practice

• Automatic systems which measure the pressure in only one arm contradict the guidelines and may miss or incorrectly classify cases of PAD.

Join the conversation @huntleighdiag #correctABI #2arms

For more information contact 029 2048 5885 or visit www.huntleigh-diagnostics.com Huntleigh Healthcare Ltd. 35 Portmanmoor Rd. Cardiff. CF24 5HN

* NICE, CG147 (Peripheral arterial disease: diagnosis and management 2018); ESC - European Society of Cardiology (Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery, European Heart Journal, 2017); ACC/AHA - American College of Cardiology/American Heart Association (Guideline on the management of Patients with Lower Extremity Peripheral Artery Disease, Circulation, 2017); Measurement and Interpretation of the Ankle-Brachial Index (Aboyans et al, Circulation, 2012); TASC2 - Inter-Society Consensus for the Management of Peripheral Arterial Disease (Journal Of Vascular Surgery, 2007)** Vowden P & Vowden K (The importance of accurate methodology in ABPI calculation when assessing lower limb wounds, BJCN, 2018)

You would NOT compress

@soap1231

Current guidelines specify you should measure both arm pressures and take the highest. (NICE, ESC, ACC/AHA, TASC2 and Aboyans et al*)

Dopplex Ability is an automatic ABI system that correctly measures systolic pressures in all four limbs.

Page 2: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected] [ 77 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

HUNTLEIGH ABI / 77

FULLY COMPLIANT WITH MBS ITEM 116101

Fee: $63.75 Benefit: 75% = $47.85 85% = $54.20

1 All Medicare Benefits Schedule (MBS) item rebates are subject to compliance with the MBS information. It is the responsibility of the user to ensure full compliance with the MBS. Visit http://www.mbsonline.gov.au for full up to date MBS information.

10 reasons why you should have the

1. Extremely easy to use and fully automatic Minimal training required

2. No need to rest patient for 15 mins Reduces total test time

3. Rapid bi-lateral ABI measurement in 3 mins Doppler based ABI typically takes 30 mins Simultaneous measurements reduces time

4. ABI can now be undertaken by healthcare support staff More cost effective measurement

5. No need to remove patient's socks or tights Maintains patient comfort and dignity

6. Easy to apply 4 cuff system Improves patient experience

7. Portable and powered by mains or rechargeable battery For home or clinical environments

8. Integral printer for documentation of results and waveforms Instant hard copy for patient notes and reimbursement

9. Automatic interpretation of ABI Reduces operator error

10. Accurate reproducible results Clinically proven by recent studies

ASK ABOUT OUR 4 WEEK TRIAL FOR YOUR PRACTICE

Page 3: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected][ 78 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

78 / HUNTLEIGH ABI

Automatic Ankle Brachial Index System

HUNDA100PB$4995 HUNDA100

$4295

Supplied with one set of standard cuffs, two rolls of paper, pack of sleeves, mains cable and instructions for use

warranty:2 years on unit

1 year on cuffs, battery &

accessories

The Dopplex eABI is supplied with one set of standard cuffs, DR4 Software (5 licenses for Free), pack of sleeves, 2 metre mini-USB to standard USB cable, mains power cable and training pack.

Printer Battery Power A/C PowerDR4

SoftwarePC Connection

Required4 Cuffs

No rest for patient

Based on volume Plethysmography

Dopplex Ability ✔ ✔ ✔ ✔ ✔ ✔

Dopplex eABI ✔ ✔ ✔ ✔ ✔ ✔

Dopplex Ability - Stand Alone UnitThe Dopplex Ability provides an immediate printout of results from the integral printer. Its portability enables measurements to be made anywhere in your primary care clinic.

Ask about our 4 week obligation free trial

Dopplex Ability eABI - PC Based UnitA USB connects the eABI device to your PC. The DR4 software provided with the unit records the results and creates a PDF for importation into your Medical software. It’s a more economical option having a lower buy price and no ongoing cost for printing paper.

Automatic Ankle Brachial Index (ABI) SystemThe Dopplex Ability has revolutionised the ABI process and provides fully automatic, easy, fast and accurate measurements. It requires minimal training and provides rapid bilateral ABI measurements in just 3 minutes.Unique patented two chamber cuff design measures systolic pressures using duo sense™ pneumatic technology based on Volume Plethysmography.

• Fully automatic, easy, fast and accurate measurements

• Minimal training required

• Patients do not need to be rested for 15 minutes

• Easy to apply 4 cuff system, can be applied over patients socks or tights

• Automatic calculation of results

• Records the highest ankle pressure in all 3 arteries

• PVR Waveforms (Pulse Volume Recordings) are also generated for accurate diagnostics

• Superior to other automatic systems especially in detecting low ankle pressures and ABIs, can detect an ABI from 0.29 - 1.57

Visit our website to watch the product video

2YRwarranty

PREMIUM PRODUCT

Supplied with FREE DR4 software. (5 licenses per unit)

Complies with International Guidelines

Page 4: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected] [ 79 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

HUNTLEIGH ABI / 79

Pictorial EvidenceInternational Guidelines (ESC, 2011) state that ABI should be undertaken on patients with suspected PAD as first line test and PVR waveforms as second line test.

The Dopplex Ability printout provides both of these requirements on one unique printout to aid the clinician in their diagnosis.

Documentation/ReportingDopplex Reporter 4 Package enables automated ABI’s to be undertaken and saved in a patient database. It also provides full page documentation hard-copy printouts and PDF file capability for interfacing to Electronic Patient Record Systems.

Fixing plate Allows easy fixing of the unit to trolley, wall mount and couch bracket HUNVAS012 $56.00Trolley 5 castor adjustable height trolley with tube management and integral basket for storage (requires fixing plate) HUNVAS013 $695.00Carry Bag Lightweight, durable case holds main unit, power cable, cuffs and tubing HUNVAS015 $135.00Sleeves Disposable sleeves to aid as infection control barrier between cuff and patient limbs Box/100 HUNACCVAS016 $56.75Paper Standard Thermal Paper Roll HUNACCVAS017 $15.90Paper Self Adhesive Thermal Label Paper Roll HUNACCVAS019 $22.50

HUNDR4 $995

The Ability Doppler uses true volume Plethysmographic technology The Ability Doppler can be used to attract the Medicare Rebate for Ankle Brachial Index Assessment; item no 11610. In purchasing a Huntleigh Ability, you can have peace of mind that your unit meets all the requirements to perform a successful ABI reading and qualify for all parts of the rebate description. The Dopplex Ability test takes less than 5 minutes per patient. The Dopplex Ability is therefore not only a great clinical addition but also a commercial value-add.

MEDICARE REBATE #11610MEASUREMENT OF ANKLE: BRACHIAL INDICES AND ARTERIAL WAVEFORM ANALYSIS, measurement of posterior tibial and dorsalis pedis (or toe) and brachial arterial pressures bilaterally using Doppler or plethysmographic techniques, the calculation of ankle (or toe) brachial systolic pressure indices and assessment of arterial waveforms for the evaluation of lower extremity arterial disease, examination, hard copy trace and report.

DR4 software is supplied free of charge with e-Ability. (5 licenses per unit)

Accessories

For more accessories visit our website www.teammed.com.auSearch for “Ability” and see the full range of spares

DOPPLERABI

PLETHYSMOGRAPHICABI (Dopplex Ability)

OSCILLOMETRICABI

> 1.3 ✔ ✔

1.0 - 1.3 ✔ ✔

0.8 - 0.99 ✔ ✔

0.5 - 0.79 ✔ ✘

< 0.5 ✔ ✘

# All Medicare Benefits Schedule (MBS) item rebates are subject to compliance with the MBS information. It is the responsibility of the user to ensure full compliance with the MBS. Visit http://www.mbsonline.gov.au for full up to date MBS information.

Page 5: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected][ 80 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

80 / HUNTLEIGH VASCULAR DOPPLERS

Dopplex® ABIAnkle Brachial Index KitThe Ankle Brachial Index (ABI) kit combines a DMX Doppler, Doppler probes and cuffs to provide the wound care or vascular specialist with a system to help in the assessment of arterial disease prior to bandaging. Doppler waveforms can be stored on the internal memory and reviewed at any time. Alternatively the waveforms can be transferred to the DR5 software package for archiving, reviewing and printing of reports.

HUNABIKIT $1695

HUNDMX $835

(base unit only; probes not included)

HUNEZ8XS

$465

The ABI kit includes:• DMX digital Doppler• Medical grade recharging kit• EZ8XS widebeam 8MHz Doppler probe• VP5XS Doppler probe• Trigger operated sphyg• Arm/Ankle cuffs (standard and large: latex free)• Educational CD• Large carry bag

See page 78 for the Automatic ABI system - dopplex Ability

ABI pressures confirmed with waveforms

warranty:3 years on unit

1 year on probes & accessories

Vascular Assessment Range

Dopplex DMX Digital Doppler with Waveform

The Bi-Directional waveform is uniquely generated from the digital Doppler spectrum. It gives the clinician objective evidence to assist in the diagnosis of vascular disease that other Dopplers may find difficult or impossible to achieve. The algorithms optimise the presentation of waveforms and enhance the quality of sound using the unique Dynamic Digital Noise Reduction (DDNR) system and gel filter. Doppler sound recording and playback is just one of the many new features in this state-of-the-art digital Doppler unit.

The key features of the DMX are:• High Resolution Colour Display• Bi-directional Waveform generated from the Digital Doppler Spectrum with Audio Scaling features• Data Storage on Micro SD Card Store waveforms and sounds for review or transfer to optional DR5 software package for printing reports and archiving.

• Integrated Charging & Connectivity• High Sensitivity Interchangeable Probes• Dynamic Digital Noise Reduction

Choose from the handy ABI or ATP kit Alternatively the DMX doppler and probes can be purchased separately.

3YRwarranty

EZ8 XS High Sensitivity 8MHz Widebeam ProbeWide beam 8MHz probe allows for easy location of vessels. Easier to maintain vessel contact during inflation and deflation.

For more information download the product brochure from our website

The DMX Vascular doppler connects to multiple High Sensitivity Probes. See the accessories brochure on our website

Page 6: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected] [ 81 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

HUNTLEIGH VASCULAR DOPPLERS / 81

Dopplex® ATPAnkle & Toe Pressure KitThe Ankle and Toe Pressure (ATP) kit is a unique combination of the DMX Doppler, probes and accessories providing the Vascular, Diabetic or Lymphatic specialist with a system to aid the assessment of arterial disease and neuropathy. The Arterial Plethysmography (APPG) probe easily attaches to the DMX Doppler unit by simply swapping your Doppler probe with its adaptor.

Arterial systolic pressure can be rapidly measured in patients with incompressible ankle arteries and can be repeated on the arms to determine the TBI. The internal pressure sensor in the adaptor provides a direct pressure reading on the Doppler display. PPG waveforms and pressures can be stored on the internal memory and reviewed at any time. Additionally the waveforms and pressures can be transferred to the DR5 software package.

ATP Kit includes:• DMX digital Doppler• Medical grade recharging kit• EZ8XS widebeam 8MHz Doppler probe• APPG probe and adaptor• Toe cuffs & inflator• Arm/Ankle cuffs (standard and large: latex free)• Trigger operated sphyg• Neuropen & box of tips (includes 10g monofilament)• Educational CD• Large carry bag

HUNDR5 $850 www.huntleigh-diagnostics.com

Toe Pressures and TBI made easy

Dopplex DR5 Reporting SoftwareDopplex DR5 is a unique vascular reporting software package for use in conjunction with the Dopplex DMX. It allows real time visualisation of waveforms on a PC. An unlimited number of traces can be transferred and stored for reviewing, archiving and printing.

• Displays Doppler colour spectral waveforms in real time• Replay of Doppler waveforms and flow separated sounds• An integral database for patient data storage and Doppler sound files• The facility to package tests together and email them for review• Storing an unlimited number and length of traces per session• A PDF generator enables the final reports to be saved and transferred to an external EPR system• Calculate Doppler indices and flow rate

warranty:3 years on unit

1 year on probes & accessories

EZ8XS Widebeam 8MHz Probe

Incorporates wide beam technology. Easier location of vessels. Easier to maintain contact during inflation and deflation.

APPG Probe

Arterial Plethysmography (APPG) probe easily attaches to the DMX Doppler unit by simply swapping your Doppler probe with it's adaptor.

3YRwarranty

HUNATPKIT $2495

Need more information? Visit our website or call our team. We are here to look after your team.

Note: Dopplex DR4 is also available for display of waveforms and data from the MD200 and Dopplex Ability - see page 79

Page 7: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected][ 82 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

82 / FOETAL DOPPLERS

...a new dimension in sound and vision

Also available

SR3 3MHz Foetal DopplerThe 3MHz probe is the probe of choice for many clinicians for use in early gestation (6-8 weeks).

3YRwarranty

HUNSR3 $995

Watch the video explaining Intelligent Intermittent

Auscultation. Visit our website

NOW YOU GET TO SEE WHAT YOU ARE HEARING

SR2 2MHz Foetal DopplerRate and Trace Display Doppler with fixed 2MHz waterproof probe

Now you can see the benefit of visual presentation of fetal heart rate in both numeric and trace views, providing you with added clinical reassurance.

• Big Numbers and Trace View Modes Viewed clearly even in bright conditions on a high definition colour display

• Improved Performance Specially designed high performance probes are optimised to perform in early gestation

• Improved Audio Reduced background and probe placement noise assists in quicker location of the foetal heart

• Enables Documentation of Intermittent Auscultation Communicates with viewing & archiving software

• Record and Playback FHR Data with Audio Using internal data storage, an added aid for training (Requires an SD card, optional extra)

This high sensitivity handheld Digital Doppler is intended for general purpose screening of the foetal heart at all stages of pregnancy from as early as 8-10 weeks, right through to labour. The attached probes are waterproof (IPX7) for high sensitivity FHR detection in both normal use and in water birth monitoring.

HUNSR2 $995 Supplied complete with: gel, soft carry bag, user manual, uses 2 x AA batteries (included)

PREMIUM PRODUCT

Page 8: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected] [ 83 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

FOETAL DOPPLERS / 83

ES-100VII foetal dopplerThe Hadeco ES-100VII is a hand held foetal Doppler featuring advanced waveform LCD and speaker

• Displays real-time foetal heart rate • Freeze key freezes heart rate for notation• LCD flashes to alert if heart is not stable • Indicates if battery is running low• Low intensity beam • Automatic shut-off• Advanced LCD and speaker• Waterproof probe• Includes carry case, battery, conducting gel and headphones• 1 year warranty

Echo Sounder ES-101EXOne-piece construction foetal doppler

• One-handed operation• 2MHz probe• Clear sound with built-in speaker• Freeze key freezes heart rate for notation• Large LCD for foetal heart rate• Automatic shut-off• Includes carry case, battery, conducting gel and headphones• 1 year warranty

$795 CRISM100VII

Hi Bebe DopplerPocket sized foetal doppler

• Colour screen - new• Compact, light and easy to use• 2MHz waterproof probe• Large display and clean sound• High sensitivity doppler probe• 10-12 week sensitivity• Continuous use for up to 6 hours• 12 months warranty

$395BIOBT200WP

$595 CRISMAP101EX

Bi-directional Doppler ES-100V3With USB interface and Software

• Bi-directional Doppler with backlit waveform LCD• Comes with 8MHz probe• Quality sound and speaker• 30 waveform memory and USB interface• Easy key to freeze waveform• Vascular Link Software Smart-V-Link for Windows with FFT analysis• Multi-probe option of 2, 4, 5, 8 & 10MHz and PPG Probe• Includes carry case, battery, conducting gel and headphones• Automatic Power Off• 12 months warranty• Also available without software

Ideal for the paperless practice.

Easy PDF report

$2090CRISM100V3 + CRIDLINK

ES-100V3 without software CRISM100V3 $1495.00

2MHz Foetal Probe CRISMAP100VX2 $695.00

Smart-V-Link Software for Windows CRIDLINK $595.00

Sonicaid FDI Doppler with foetal heart rate display

The FD1 combines high sensitivity with excellent audio quality. It is easy to use and provides optimum foetal heart detection from 8-10 weeks gestation.

The FD1’s active noise reduction technology ensures crystal clear audio and the high sensitivity 2MHz probe is waterproof.

• Advanced real time auto-correlation foetal heart rate processing • Active noise reduction for crystal clear foetal heart sounds • Waterproof probe suitable for use in a water birthing environment • Advanced power management with auto switch-off to conserve battery life • Long robust coiled cable enables optimum probe position in all circumstances • Large carry bag • 5 year warranty

5YRwarranty$895 HUNFD01

Page 9: Ankle Brachial Index Why it is essential to measure both arms · 2020-03-04 · product brochure from our website The DMX Vascular doppler connects to multiple High Sensitivity Probes

All prices are subject to 10% GST unless marked with * (GST Free)BP Medical (WA) | www.bpmedical.com.auPHONE 1300 33 55 60 | [email protected][ 84 ]

Team Medical | www.teammed.com.au PHONE 1300 22 44 50 | [email protected]

supplies

84 / HADECO VASCULAR DOPPLERS

Smartdop™ 45 with 8MHz probeBi-directional Doppler with waveform LCD & fast printer and 2 probe ports

All you need in a hand-held vascular doppler with printer. Prints high resolution waveforms in real-time as well as numerical data.

• Now comes standard with 2 probe ports• Fast printer for immediate data output• Comes with 8MHz probe• Stores up to 30 patient waveforms• Various mode settings are available for optimal measurement• Multi-probe option of 2, 4, 5, 8 & 10MHz and PPG Probe• Automatic power “Off” • Optional connection to Smart-V-Link Software for data download• Built in rechargeable battery• Includes carry case, battery, conducting gel and headphones• 12 month warranty• Made in Japan

2Mhz Foetal Probe CRISMAP100VX2 $695.00

PPG/PV Probe CRISMAPPG21 $795.00

Paper for Smartdop 45 DOPPAP900 $13.90

Smart-V-Link Software for Windows CRIDLINK $595.00

CRISMADOP45W $2395

$3295CRISMADOP30EX

Includes 2mhz foetal probe

Smartdop™ 30EXBi-directional Doppler for ABI/TBI studies with built-in cuff inflator(ABI= Ankle brachial index ) (TBI = Toe brachial index)

• Doppler blood pressure recorder• Full auto system with built-in cuff inflator• Stores up to 30 patient waveforms• Calculates and prints ABI/TBI and pressure documentation• Comes with 8MHz probe• Two probe combination of 2, 4, 5, 8 & 10MHz, PPG and PV Probe• Automatic power “Off” • Optional connection to Smart-V-Link Software for data download• Built in rechargeable battery• Additional cuffs and toe cuffs available• 12 month warranty• Made in Japan

Clinical Applications:– Ankle Brachial Index (ABI) – Toe Brachial Index (TBI)– Bi-directional lower extremity studies– Blood pressure segmental studies– Peripheral vascular procedures– Penile & digit systolic pressures– Toe pressures & venous reflux studies (PPG)

Paper for Smartdop 30EX DOPPAP900 $13.90

Smart-V-Link Software for Windows CRIDLINK $595.00