ariston clas he wall-hung high efficiency gas boilers ... · wall-hung high efficiency gas boilers...
TRANSCRIPT
Supplied By www.heating spares.co Tel. 0161 620 6677
Elegant, efficientand intelligent
CLAS HE
Pantone 187
CMYK 100m 79y 20k
Cool Grey 7
30% Black
Font family:
DIN
Adobe Garamond
I
WALL-HUNG HIGH EFFICIENCYGAS BOILERS
Heating Hot water Renewables
Supplied By www.heating spares.co Tel. 0161 620 667722
The high efficiency boilerthat saves onenergy and costs
With specified intelligence,CLAS HE adapts to the householder's requirements
The CLAS HE range of boilersincorporate Ariston’s innovative AUTOfunction, which enables the boiler tooperate more efficiently by intelligentlychoosing the correct temperature forthe central heating circuit.
CLAS HE also features an LCD displaywhich, as well as displaying informationon the boiler's operation, will alsodisplay an error code in the event of ashut-down to help easily determinethe cause.
Supplied By www.heating spares.co Tel. 0161 620 667733
Home comfortwith CLAS HE
n SEDBUK Band An NOx Class 5n High combi DHW flow rates
15.6 l/min ∆T = 35ºC (38kW model)n Compact dimensionsn 5 year guaranteen Self diagnostic displayn Multiple flue optionsn Extensive range of controls and
accessories availablen Stainless steel heat exchanger
Easy toinstall and service
The CLAS HE boiler has been designed with ease of installation in mind and the boiler features a simple connectionkit, which includes a filling loop. And to ensure a tidy finish to the installation, CLAS HE also has a clip-on connectionkit cover.
With the range of installation accessories available, it is possible to; pre-plumb and test the heating system beforefitting the boiler, run the pipe work behind the boiler (using the optional rear piping chassis) and, through the plumemanagement kit, offer more siting options.
Access to the boiler is straightforward and all components inside the boiler are easily reached.
Supplied By www.heating spares.co Tel. 0161 620 667744
The latest technologyMaximum comfort
Easy installation, hassle freeservicingThe CLAS HE range has been designed with the installer in mind.The dimensions between the pipe work connections and the flue has been reduced, allowing for a lower fixing height.The combi and system boiler versions feature a simple connection kit, which includes a filling loop as standard.All components are easily accessible and require a minimal amount of tools for servicing and maintenance.
Supplied By www.heating spares.co Tel. 0161 620 667755
Installer benefitsn SEDBUK Band An Filling loop (combi and system versions)n Mechanical time clock (combi versions)n Rear piping chassis available as an option (combi and system versions)n Reduced fixing height between pipe work and fluen Multiple flueing optionsn Easily accessible for servicing and maintenancen Wide range of control and installation accessories available
Simple controlsThere is an extensive selection of easy to use controls available for the CLASHE range. The controls are available as both wired and wireless (allowinginstallation without the need for a qualified electrician).
These, in conjunction with the AUTO function, will enable the boiler to work at its most efficient to achieve the desired room temperature.
Stylish design andLCD display
Supplied By www.heating spares.co Tel. 0161 620 667766
Weather Compensation -As Easy as Ariston Boiler &Controls
The advanced AUTO function ensures intelligent management of the roomtemperature whilst guaranteeing maximum energy efficiency and offeringenergy savings.By pressing the AUTO button on the CLAS HE control panel, the boiler willautomatically choose the ideal temperature for the central heating circuitby gradually increasing the temperature of the system water until the roomreaches the set temperature, whilst guaranteeing no excessive peaks in theflow temperature.When used in conjunction with the extensive range of controls, the AUTOfunction ensures greater levels of comfort and savings are achieved.With the AUTO function activated and by fitting an outdoor sensor, with themodulating room sensor, savings in excess of 10% can be achieved.
Customisedcomfort,unrivaledperformance
temperature
time
Supplied By www.heating spares.co Tel. 0161 620 66777
Advanced,intelligentfunctions
7
Outdoor SensorModulating Room Sensor Signal Receiver Room Thermostat
Ariston also offers an extensive range of temperature controls for use withthe CLAS HE range.
These are available either as hard wired or wireless, and include on-off roomthermostats, modulating room sensors, outdoor sensors and programmableroom thermostats.
The wireless controls can be fitted without the need for a qualified electrician.
Multi-functionalLCD interface
Remote control Clima Manager
1
7
32
134
65
14
121110
98
1 Information button2 Auto/manual button3 Multifunction button4 Operation mode button5 Hot water and heating
temperature set button 6 Heating mode button7 Special functions button
8 Auto function button9 Date/time set button10 Language selection button11 Comfort button12 Display-on button13 Reset button14 Menu/enter button
MULTI-ZONE SYSTEMSThe temperature can be controlled separatelyfor 2 different areas. For example, one areawith a floor installation (low temperature)controlled by the Clima Manager and anotherwith a traditional radiator-type installation (hightemperature) controlled by a room thermostat.
Programmable RoomThermostat
Supplied By www.heating spares.co Tel. 0161 620 667788
CLAS HE COMBI
WALL-HUNG HIGH EFFICIENCYGAS COMBINATION BOILERS
24 FF - 30 FF38 FF
n AUTO-DIAGNOSTIC SYSTEM
n SIMPLE MAINTENANCE WITH ACCESSFROM THE FRONT OF THE APPLIANCE
n ANTI-FROST AND ANTI-SCALE DEVICE
n BUILT-IN AUTOMATIC BY-PASS
n BUILT-IN MECHANICAL TIME CLOCK
n INCLUDES CONNECTION KIT ANDFILLING LOOP
n CLIP-ON CONNECTION KIT COVER ASSTANDARD
n SEDBUK BAND A
n AVAILABLE IN THREE OUTPUTS
n HIGH HOT WATER FLOW RATES
n COMPREHENSIVE RANGE OF WIREDAND WIRELESS CONTROLS
n UNIQUE 'AUTO' FUNCTION OPTIMISESEFFICIENCY OF BOILER AND SYSTEM
n COMFORT SWITCH (PRE-HEAT HOTWATER FUNCTION)
LEGENDA: Central heating flow 22mm compressionB: Domestic hot water outlet
15mm compressionC: Gas inlet 15mm compressionD: Domestic hot water inlet
15mm compressionE: Central heating return 22mm compressionF: Flue (Ø mm)
F1: 60/100 - 80/125F2: 80
band Acomfort functionenergy savingextra safe IPX5D
Coaxial exhaust
Twin pipe exhaust
QUIETOPERATION
COMPACTDIMENSIONS
ENERGYEFFICIENT
AUTO
Supplied By www.heating spares.co Tel. 0161 620 667799
flow rate l/h100 200 300 400 500 600 700 800 900 1000 1100 1200 13001400
100
200
300
400
500
600mbar
1
2
Graph of boiler residual head ∆T20oC1 High Speed2 Low Speed
NTC1
OT
NTC2
A B C D E
ROOM SEALED FAN FLUE
maximumflexibility
CLAS HE CLAS HE CLAS HE24 FF 30 FF 38 FF
EFFICIENCYSEDBUK Rating Band A A ASAP efficiency % 90.3 90.3 90.1
POWER & PERFORMANCEHeat input max. kW - Btu/h 27.8 - 94,500 33.3 - 113,600 42.2 - 144,000Heat input min. kW - Btu/h 6.1 - 20,800 7.2 - 24,500 8.3 - 28,300Heat output max. (C.H.) kW - Btu/h 21.0 - 71,600 27.0 - 92,100 30.0 - 102,300Heat output max. (D.H.W.) kW - Btu/h 25.0 - 85,300 30.0 - 102,300 38.9 - 132,700Heat output min. kW - Btu/h 5.0 - 17,000 6.0 - 22,000 7.1 - 24,200Central heating temp. max. (high temp.) °C 82 82 82Central heating temp. min. (high temp.) °C 35 35 35Central heating temp. max. (low temp.) °C 45 45 45Central heating temp. min. (low temp.) °C 20 20 20D.H.W. temperature maximum °C 60 60 60D.H.W. temperature minimum °C 36 36 36D.H.W. flow rate ∆T = 35°C l/min 10.3 12.9 15.6D.H.W. flow rate ∆T = 35°C gal/min 2.2 2.8 3.4
CHARACTERISTICSMinimum ambient temperature °C 5 5 5D.H.W. minimum flow rate l/min 2.0 2.0 2.0Domestic hot water pressure maximum bar 7 7 7Domestic hot water pressure minimum bar 0.3 0.3 0.3Built-in expansion vessel capacity l 8 8 8Built-in expansion vessel pre-charged pressure bar 0.7 0.7 0.7Maximum water content of system l 100 100 100Maximum heating pressure bar 3 3 3Servicing clearances - top/front/bottom mm 300/450/300 300/450/300 300/450/300Servicing clearances - left/right mm 5/5 5/5 5/5Zero compartment ventilation Yes Yes YesWeight kg 32 35 35
ELECTRICAL DATAElectrical supply V/Hz 230/50 230/50 230/50Power consumption W 114 115 150Protection grade of electrical system IP X5D X5D X5DInternal fuse rating 2A Fast Fuse 2A Fast Fuse 2A Fast Fuse
PRODUCT CODE 3665032 3665033 3665072
Technical Information
Code
WIRED CONTROLSDigital Time Clock (Integral) 3318463On/Off Room Thermostat 3318238On/Off Programmable Room Thermostat 3318239Modulating Room Sensor 3318447Outdoor Sensor 3318232Clima Manager 3318230
WIRELESS CONTROLSOn/Off Programmable Room Thermostat 3318241Receiver (On/Off Controls) 3318240
GENERAL ACCESSORIESRear Piping Chassis 3678411Metal Template 3318246Pre-Installation Kit (UK) 3678356Pre-Installation Kit (IE) 3678420Clip-in (2 Zone Control) 3318242System Cleaner 705998
Accessories
Supplied By www.heating spares.co Tel. 0161 620 667710
WALL-HUNG HIGH EFFICIENCYGAS SYSTEM BOILERS
10
CLAS HE SYSTEM
18 FF - 24 FF30 FF
n BUILT-IN AUTOMATIC BY-PASS
n INCLUDES CONNECTION KIT ANDFILLING LOOP
n CLIP-ON CONNECTION KIT COVER AS STANDARD
n SEDBUK BAND A
n AVAILABLE IN THREE OUTPUTS
n COMPREHENSIVE RANGE OF WIREDAND WIRELESS CONTROLS
n UNIQUE 'AUTO' FUNCTION OPTIMISESEFFICIENCY OF BOILER AND SYSTEM
n AUTO-DIAGNOSTIC SYSTEM
n SIMPLE MAINTENANCE WITH ACCESSFROM THE FRONT OF THE APPLIANCE
LEGENDA: Central heating flow 22mm compressionC: Gas inlet 15mm compressionE: Central heating return 22mm compressionF: Flue (Ø mm)
F1: 60/100 - 80/125F2: 80
band Aenergy savingextra safe IPX5D
QUIETOPERATION
COMPACTDIMENSIONS
SAVINGAUTO
Coaxial exhaust
Twin pipe exhaust
Supplied By www.heating spares.co Tel. 0161 620 66771111
flow rate l/h100 200 300 400 500 600 700 800 900 1000 1100 1200 13001400
100
200
300
400
500
600mbar
1
2
Graph of boiler residual head ∆T20oC1 High Speed2 Low Speed
highlyadaptable
Technical InformationCLAS HE SYSTEM CLAS HE SYSTEM CLAS HE SYSTEM
18 FF 24 FF 30 FF
EFFICIENCYSEDBUK Rating Band A A ASAP efficiency % 90.2 90.4 90.4
POWER & PERFORMANCEHeat input max. kW-Btu/h 20.0 - 68,200 27.7 - 94,500 33.3 - 113,600Heat input min. kW-Btu/h 5.0 - 17,000 6.1 - 20,800 7.2 - 24,500Heat output max. (C.H.) kW-Btu/h 17.6 - 60,000 21.0 - 71,600 27.0 - 92,100Heat output min. kW-Btu/h 4.2 - 14,300 5.0 - 17,000 6.0 22,000Central heating temp. max. (high temp.) °C 82 82 82Central heating temp. min. (high temp.) °C 35 35 35Central heating temp. max. (low temp.) °C 45 45 45Central heating temp. min. (low temp.) °C 20 20 20
CHARACTERISTICSMinimum ambient temperature °C 5 5 5Built-in expansion vessel capacity l 8 8 8Built-in expansion vessel pre-charged bar 0.7 0.7 0.7Maximum water content of system l 100 100 100Maximum heating pressure bar 3 3 3Servicing clearances - top/front/bottom mm 300/450/300 300/450/300 300/450/300Servicing clearances - left/right mm 5/5 5/5 5/5Zero compartment ventilation Yes Yes YesWeight kg 31 32 35
ELECTRICAL DATAElectrical supply V/Hz 230/50 230/50 230/50Power consumption W 105 114 115Protection grade of electrical system IP X5D X5D X5DInternal fuse rating 2A Fast Fuse 2A Fast Fuse 2A Fast Fuse
PRODUCT CODE 3665073 3665070 3665071
Code
WIRED CONTROLSOn/Off Room Thermostat 3318238On/Off Programmable Room Thermostat 3318239Modulating Room Sensor 3318447Outdoor Sensor 3318232Clima Manager 3318230
WIRELESS CONTROLSOn/Off Programmable Room Thermostat 3318241Receiver (On/Off Controls) 3318240
GENERAL ACCESSORIESRear Piping Chassis 3678411Metal Template 3318246Pre-Installation Kit (UK) 3678356Pre-Installation Kit (IE) 3678420Clip-in (2 Zone Control) 3318242System Cleaner 705998
Accessories
NTC1
OT
NTC2
A C E
ROOM SEALED FAN FLUE
Supplied By www.heating spares.co Tel. 0161 620 66771212
CLAS HE R
WALL-HUNG HIGH EFFICIENCYGAS REGULAR BOILERS
12 FF - 18 FF24 FF
n SIMPLE MAINTENANCE WITH ACCESSFROM THE FRONT OF THE APPLIANCE
n FOR USE ON OPEN VENTED ANDSEALED SYSTEMS
n ANTI-FROST PROTECTION
n SEALED SYSTEM KIT AVAILABLE AS ANOPTIONAL EXTRA
n 240V SWITCHING
n SEDBUK BAND A
n AVAILABLE IN THREE OUTPUTS
n UNIQUE 'AUTO' FUNCTION OPTIMISESEFFICIENCY OF BOILER AND SYSTEM
n TWO ZONE TEMPERATUREMANAGEMENT ALLOWS OPTIMISATIONAND EASY UPGRADE OF STANDARDSYSTEMS
n COMPATIBLE WITH OUTDOOR SENSOR
n AUTO-DIAGNOSTIC SYSTEM
LEGENDA: Central heating flow 22mm compressionC: Gas inlet 15mm compressionE: Central heating return 22mm compressionF: Flue (Ø mm)
F1: 60/100 - 80/125F2: 80
band Aenergy savingextra safe IPX5D
QUIETOPERATION
COMPACTDIMENSIONS
SAVINGAUTO
Coaxial exhaust
Twin pipe exhaust
Supplied By www.heating spares.co Tel. 0161 620 66771313
totallyversatile
Technical InformationCLAS HE R CLAS HE R CLAS HE R
12 FF 18 FF 24 FF
EFFICIENCYSEDBUK Rating Band A A ASAP efficiency % 90.2 90.4 90.4
POWER & PERFORMANCEHeat input max. kW-Btu/h 12.0 - 40,900 20.0 - 68,200 22.0 - 75,000Heat input min. kW-Btu/h 3.0 - 10,200 5.0 - 17,000 5.5 - 18,800Heat output max. (C.H.) kW-Btu/h 11.7 - 40,000 17.6 - 60,000 21.6 - 73,700Heat output min. kW-Btu/h 2.8 - 9,500 4.2 - 14,300 5.2 - 17,700Central heating temp. max. (high temp.) °C 82 82 82Central heating temp. min. (high temp.) °C 35 35 35Central heating temp. max. (low temp.) °C 45 45 45Central heating temp. min. (low temp.) °C 20 20 20
CHARACTERISTICSMinimum ambient temperature °C 5 5 5Servicing clearances - top/front/bottom mm 250/450/300 250/450/300 250/450/300Servicing clearances - left/right mm 5/5 5/5 5/5Zero compartment ventilation Yes Yes YesWeight kg 23 23 23
ELECTRICAL DATAElectrical supply V/Hz 230/50 230/50 230/50Power consumption W 87 105 114Protection grade of electrical system IP X5D X5D X5DInternal fuse rating 2A Fast Fuse 2A Fast Fuse 2A Fast Fuse
PRODUCT CODE 3665086 3665087 3665088
Code
HYDRAULIC ACCESSORIESSealed System Kit 3678458
WIRED CONTROLSOn/Off Room Thermostat 3318238Outdoor Sensor 3318232Twin Channel Digital Programmer 3318412
WIRELESS CONTROLSTwin Channel Digital Programmer 3318413
Accessories
NTC1OT
NTC2
ROOM SEALED FAN FLUE
Supplied By www.heating spares.co Tel. 0161 620 66771414
Flue pipe accessories-Easy installation with unrivaled flexibility
Ariston boilers are designed to be completely adaptable to every possibleflue situation that may be encountered during installation. The need foralteration to flue components is almost completely eliminated, makinginstallation of the boiler quick and easy. It is possible to site flue terminalsin a variety of positions in accordance with BS5440-1:2000.
TERMINAL POSITION mm
A Directly above/below an opening, air brick, opening windows, etc 300B Horizontally to an opening, air brick, opening windows, etc 300C Below gutters, soil pipes or drain pipes 75D Below eaves 200E From vertical drain or soil pipe 75F From an internal or external corner 300G Above ground roof or balcony level 2100H From a surface facing the terminal 2500I From a terminal facing the terminal 2500J Vertically from a terminal on the same wall 1500K Horizontally from a terminal in the same wall 300L Fixed by use of terminal and matched flashing plate -
NOTE
- Do not install in a place likely to causea nuisance/damage/discolouration
- Carport installations not acceptablewith HE appliances
- Products should not cross propertyboundaries (2.5 metres)
Installationconditions
Supplied By www.heating spares.co Tel. 0161 620 66771515
Flue Accessories
Description Code
COAXIAL SYSTEMS 60/100Horizontal Coaxial Kit - 1000mm 3318073Horizontal Coaxial Kit + Vertical Starter 331807490º Coaxial Elbow 331807545º Coaxial Elbow (Pack of 2) 3318076Coaxial Extension - 2000mm 3318465Coaxial Extension - 1000mm 3318077Coaxial Extension - 500mm 3318078Vertical Starter 3318079Vertical Flue with Black Terminal 3318080Vertical Flue with Red Terminal 3318081Plume Kit (inc. 1000mm Horizontal Terminal) 3318329Plume Extension (∅60mm) - 1000mm 3318105Plume 45º MF Elbow (∅60mm) (Pack of 2) 3318106
COAXIAL SYSTEMS 80/125Horizontal Coaxial Kit + Adaptor (∅80/125) 331809090º Coaxial Elbow (∅80/125) 331809145º Coaxial Elbow (∅80/125) 3318092Coaxial Extension - 2000mm (∅80/125) 3318466Coaxial Extension - 1000mm (∅80/125) 3318093Coaxial Extension - 500mm (∅80/125) 3318094Adaptor/Vertical Starter (∅60/100 - ∅80/125) 3318095Vertical Flue with Black Terminal 3318080Vertical Flue with Red Terminal 3318081Adaptor (∅80/125 - ∅60/100) 3318200
TWIN PIPE SYSTEMS ∅80/80Adaptor (∅60/80) for Twin Pipe Systems 3318369Horizontal Twin Pipe (∅80) Flue Kit 331837090º MF Elbow (∅80) 331808445º MF Elbow (∅80) (Pack of 2) 3318085Extension - 1000mm (∅80) 3318086Extension - 500mm (∅80) 3318087Adaptor ∅80/125 - ∅80 for Vertical Termination 3318088Adaptor ∅80/125 - ∅80 for Vertical Termination 3318089Vertical Flue with Black Terminal 3318080Vertical Flue with Red Terminal 3318081Stainless Steel Exhaust Cap Adaptor (∅80) 3318027Intake Vent Cap (∅80) 3318028
SUNDRY ITEMSBlack Lead Flashing Base Cap (12-40º) 3318009Red Lead Flashing Base Cap (12-40º) 3318010Black Vent Cap Base for Flat Roof 3318011Red Vent Cap Base for Flat Roof 3318012Wall Bracket Kit (∅80-∅125) (Pack of 3) 3318015Cover Plate (∅100) 3318016Plume Deflector (45º) 3829009
MODEL 12 FF 18 FF 24 FF 30 FF 38 FF
MAX FLUE LENGTHS
Horizontal Coaxial 60/100 (m) 16 14 12 10 6
Horizontal Coaxial 80/125 (m) 48 42 36 30 18
Vertical Coaxial 60/100 (m) 16 14 12 10 8
Vertical Coaxial 80/125 (m) 56 49 42 35 21
Twin Pipe (equal lengths*) 48 + 48 42 + 42 36 + 36 30 + 30 18 + 18
* Other Twin Flue configurations are available, please refer to product manual for exact details.
Supplied By www.heating spares.co Tel. 0161 620 6677
Inth
ein
tere
sts
ofou
rcu
stom
ers,
Aris
ton
Ther
mo
(UK)
Ltd
isco
ntin
ually
deve
lopi
ngth
ese
prod
ucts
toim
prov
ebo
thpe
rfor
man
cean
dde
sign
.We
ther
efor
ere
serv
eth
erig
htto
chan
gesp
ecifi
catio
nw
ithou
tprio
rno
tice.
This
broc
hure
isac
cura
teat
the
date
ofpr
intin
g.Co
nsum
erst
atut
ory
right
sar
eno
taffe
cted
.
0870 241 8180technical advice
0870 600 9888customer service
0870 241 8180technical advice
0870 600 9888customer service
0870 241 8180technical advice
0870 600 9888customer service
Oct
ober
2010
-on
-lin
eve
rsio
n
Technical Advice & Customer ServiceFax 01494 [email protected]@aristonthermo.com
www.ariston.co.uk
ARISTON THERMO GROUPAriston Thermo UK LtdAriston BuildingHughenden AvenueHigh WycombeBucks HP13 5FTTelephone 01494 755600Fax 01494 459775