Page 1: Aritech Master Fire Product Catalogue (06.12.05)

GESecurity

Aritech Fire Systems Products Catalogue

g

Page 2: Aritech Master Fire Product Catalogue (06.12.05)
Page 3: Aritech Master Fire Product Catalogue (06.12.05)

In this catalogue you will find a wide range of

Fire Protection equipment from GE Security.

GE Security is a global technology leader dedicated

to supporting the needs of the rapidly growing

electronic security industry and to expanding

current technologies, products and services that

create revenue growth opportunities for its

customers. As part of the GE family, GE Security

shares the spirit of innovation that has

distinguished GE for well over 100 years. GE

Security's commitment to the ongoing success of

its partners and affiliates means that we maintain

a sharp focus on product and service innovation,

world-class manufacturing practices and

operational excellence.

GE Security is a worldwide organisation with sales

and technical support operations in 27 countries,

and manufacturing and logistics operations in

Europe, the U.S. and China.

GE Security has expertise in all areas of electronic

security, including:

Intrusion and Fire Protection

Electronic Access and Facility Management

Key Management and Remote Access Systems

and Services

Fibre Optic Transmission and Reception

Equipment

CCTV, Digital Video and Surveillance Equipment

Video Multiplexing and Digital Storage

When you're looking for the finest in Fire

Protection products with leading-edge

technology and the backing of a world leader, you

need look no further than this catalogue.

GE Security,unrivalled expertise in Fire Protection

Page 4: Aritech Master Fire Product Catalogue (06.12.05)
Page 5: Aritech Master Fire Product Catalogue (06.12.05)

Perimeter detection

Page : 3

DI322IIonisation detector, conventional

The 300 Series conventional fire detectors are the ideal solution for anyconventional installation. They are built specifically for use with theAritech FP400, FP500, FP600 and FP700 series conventional fire panels,but can also be connected to most 3rd party industry standardconventional control panels.

Specifications

Operating voltage 18 to 28 VDC

Current consumption

Quiescent at 24 VDC 30 A

Alarm at 24 VDC < 100 mA

Radio-active source Americium 241

Average activity 0.33 +/-0.04 Ci (12.1 +/- 1.5 kBq)

Remote alarm output < 100 mA

Heat specification

Operating temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Humidity (non-condensing) 0 - 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Ionisation detector, conventionalDI322I Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L

Full line consisting of Optical, Ionisation and Heatdetectors

E

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approved *E

Innovative base compensates for uneven surfacesE

Page 6: Aritech Master Fire Product Catalogue (06.12.05)

Page : 4

DP331IOptical detector, conventional, with field exchangeable optical block

The 300 Series conventional fire detectors are the ideal solution for anyconventional installation. They are built specifically for use with theAritech FP400, FP500, FP600 and FP700 series conventional fire panels,but can also be connected to most 3rd party industry standardconventional control panels.

Specifications

Operating voltage 9 to 28 VDC

Current consumption

Quiescent at 24 VDC 85 A

Alarm at 24 VDC < 100 mA

Radio-active source

Average activity

Remote alarm output < 100 mA

Heat specification

Operating temperature -10 °C to +70 °C

Storage temperature -10 °C to +70 °C

Humidity (non-condensing) 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Optical detector, conventional, with field exchangeable optical blockDP331I Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705DConventional 12 VDC fire detector base with relayKZ705R Low current remote LED indicatorPA25/3L

Full line consisting of Optical, Ionisation and Heatdetectors

E

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approved *E

Innovative base compensates for uneven surfacesE

Page 7: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 5

DT313ITemperature detector (fixed and rate-of-rise), conventional

The 300 Series conventional fire detectors are the ideal solution for anyconventional installation. They are built specifically for use with theAritech FP400, FP500, FP600 and FP700 series conventional fire panels,but can also be connected to most 3rd party industry standardconventional control panels.

Specifications

Operating voltage 18 to 28 VDC

Current consumption

Quiescent at 24 VDC 70 A

Alarm at 24 VDC < 100 mA

Radio-active source

Average activity

Remote alarm output < 100 mA

Heat specification Max. & ROR to EN54p5

Operating temperature -10 °C to +70 °C

Storage temperature -10 °C to +80 °C

Humidity (non-condensing) 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Temperature detector (fixed and rate-of-rise), conventionalDT313I Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L

Full line consisting of Optical, Ionisation and Heatdetectors

E

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approved *E

Innovative base compensates for uneven surfacesE

Page 8: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 6

KCT731Calibration Tool for KL731/DP331I Fire Detectors

The KCT731 is a calibration tool to recalibrate the conventionaldetectors after replacement of the field exchangeable optical block.

Specifications

Supply 2 x 9 V batteries

Dimensions (w x h x d) 104 x 195 x 63 mm

Ordering Information

Calibration Tool for KL731/DP331I Fire DetectorsKCT731

Easy to useE

Simple "go/no-go" functionE

Battery operatedE

Page 9: Aritech Master Fire Product Catalogue (06.12.05)

Detector Bases & Accessories

Page : 7

KZ700Universal fire detector base

The KZ700 is a 4 contact universal detector base. It has the ability tocompensate for uneven mounting surfaces. It is also available in blackfor special applications in false ceilings.

Specifications

Dimensions

Diameter 104 mm

Height 24 mm

Ordering Information

Universal fire detector base KZ700Universal fire detector base (for KL700/A and Dx300/1500) - BlackKZ700B

Polarity sensitiveE

Universal base fits conventional and analoguedetectors

E

Compensates for uneven surfacesE

Remote indicator contact availableE

EN54 approvedE

Variant in black also availableE

Page 10: Aritech Master Fire Product Catalogue (06.12.05)

Detector Bases & Accessories

Page : 8

KZ705Universal fire detector base with earth connection

The KZ705 is a 5 contact universal detector base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.In addition to the normal base and remote indication connectors, theKZ705 also has an additional earth terminal connector to allow foreasy terminations of a possible cable screen.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage -

Current Consumption -

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 to 70 °C

Storage Temperature -10 to 70 °C

Relative Humidity (max) 95 % (non-cond.)

Ordering Information

Universal fire detector base with earth connectionKZ705

Polarity sensitiveE

Universal base fits conventional and analoguedetectors

E

Additional earth terminal availableE

Remote indicator contact availableE

Page 11: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 9

KZ705DConventional fire detector base with diode

The KZ705D is a 5 contact universal detector base for use with theKL700/Dx300 series detectors from GE-Interlogix. In addition to thenormal base and remote indication connectors, the KZ705D also hasan additional earth terminal connector to allow for easy terminationsof a possible cable screen. The built in diode is specifically targeted atsystems using active end-of-line devices.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage -

Current Consumption -

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 to 70 °C

Storage Temperature -10 to 70 °C

Relative Humidity (max) 95 % (non-cond.)

Ordering Information

Conventional fire detector base with diodeKZ705D

Polarity sensitiveE

Universal base for conventional detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in diode for active end-of-line systemsE

EOL-ACTActive end-of-line device for use with FP400/KL700 fire panels

The EOL-ACT is designed for use with the NK700/FP400 fire panels fromGE-Interlogix. It is an active end-of-line device to allow the monitoringof a conventional zone through a diode base (such as the KZ705D).

Ordering Information

Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACT

SmallE

Easy to installE

Page 12: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 10

KZ705RConventional 12 VDC fire detector base with relay

The KZ705R is a 5 contact detector base for use with the KL731/DP331Idetectors from GE-Interlogix. In addition to the normal base andremote indication connectors, the KZ705R also has an additional earthterminal connector to allow for easy terminations of a possible cablescreen. A built in 12 V relay makes it ideal for use on low voltageintrusion systems.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage 12 V ± 10%

Current Consumption 12 A

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humdity 95 % (non cond.)

Ordering Information

Conventional 12 VDC fire detector base with relayKZ705R

Polarity sensitiveE

12 V relay for 4 wire systemsE

Additional earth terminal availableE

Remote indicator contact availableE

Page 13: Aritech Master Fire Product Catalogue (06.12.05)

Detector Bases & Accessories

Page : 11

S700Surface mount accessory for KZ700 and KZ705 series bases

The S700 is a base accessory designed for use with the KZ700 seriesdetector bases. It allows for a surface mount conduit and cable toenter the base from the side. The KZ700 series base fits on top of thisaccessory.

Specifications

Dimensions

Diameter 95 mm

Height 30 mm

Ordering Information

Surface mount accessory for KZ700 and KZ705 series basesS700

Surface mount accessory for KZ700 series basesE

Page 14: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 12

DP721IPhotoelectric smoke detector with remote alarm LED output

700 seriesThe smoke detector continually monitors its own sensitivity andoperational status. Once a day, it performs a full diagnostic test whichincludes dynamically testing the sensing chamber and internalelectronics.

Specifications

Operating voltage 8.5 - 33 V dc

Current consumption

Quiescent at 24 V dc 100 A; Max. 70 A average

In alarm at 24 V dc 60 mA

Alarm indication White LED (red alarm)

Fault indication Yellow LED

Remote alarm output 30 mA

RY contact rating

Relay models 2 A @ 30 V dc;1 A @ 120 V ac

Humidity 0 - 95%; Non-condensing

IP rating IP 43

Operating temperature -10°C - 60°C

Sensitivity 10%/m (+1.6%, -3.3%)

Reset voltage 2,5 V max

Reset time 1 sec

Dimensions 10 cm Ø, H = 5 cm

Ordering Information

Photoelectric smoke detector with remote alarm LED outputDP721IPhotoelectric smoke detector with C/O relay outputDP721R10 cm diameter base - 6 terminalsDB702

Automatic Self Diagnostics : Dynamic full detector test,Sensitivity test

E

Manual Self Diagnostic routine with visual sensitivityindication

E

Field sensitivity testing without external metersE

Field exchangeable and disposable optical chamberE

High false alarm immunityE

Floating background with drift compensationE

Separate fire and trouble LEDE

12 - 24 V dc operationE

Polarity insensitiveE

Full range : optical, heat and optical/heat multi criteriasensor

E

EN 54 approvedE

Page 15: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 13

DP721TPhotoelectric smoke and heat detector head with remote alarm LED

700 seriesFitted with a field-exchangeable optical block. The smoke detectorcontinually monitors its own sensitivity and operational status. Once aday, it performs a full diagnostic test which includes dynamicallytesting the sensing chamber and internal electronics.

Specifications

Operating voltage 8.5 - 33 V dc FWR

Current consumption

Quiescent at 24 V dc 100 A; Max. 70 A average

In alarm at 24 V dc 60 mA

Alarm indication White LED (red alarm)

Fault indication Yellow LED

Remote alarm output 30 mA

RY contact rating 2 A @ 30 V dc;1 A @ 120 V ac

Humidity 0 - 95%; Non-condensing

IP rating IP 43

Sensitivity 10%/m (+1.6%, -3.3%)

Reset voltage 2,5 V max

Reset time 1 sec

Dimensions 10 cm Ø, H = 5 cm

Ordering Information

Photoelectric smoke and heat detector head with remote alarm LEDDP721TPhotoelectric smoke and heat detector with relay outputDP721RTPhotoelectric smoke and heat detector with relay output, autoresetDP721RTA10 cm diameter base - 6 terminalsDB702

Automatic Self Diagnostics : Dynamic full detector test,Sensitivity test

E

Manual Self Diagnostic routine with visual sensitivityindication

E

Field sensitivity testing without external metersE

Field exchangeable and disposable optical chamberE

High false alarm immunityE

Floating background with drift compensationE

Separate fire and trouble LEDE

12 - 24 V dc operationE

Polarity insensitiveE

Full range : optical, heat and optical/heat multi criteriasensor

E

EN 54 approvedE

Page 16: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 14

DT713-557º C fixed and rate-of-rise heat detector

700 seriesThe smoke detector continually monitors its own sensitivity andoperational status. Once a day, it performs a full diagnostic test whichincludes dynamically testing the sensing chamber and internalelectronics.

Specifications

Operating voltage 8.5 - 33 V dc FWR

Current consumption

Quiescent at 24 V dc 100 A; Max. 70 A average

In alarm at 24 V dc 60 mA

Alarm indication Red LED

Fault indication Yellow LED

Remote alarm output 30 mA

RY contact rating 2 A @ 30 V dc;1 A @ 120 V ac

Humidity 0 - 95%; Non-condensing

IP rating IP 43

Heat specification

Max. 57º C ± 1.5º C

R.O.R. 8º C/min and > 40° C

Sensitivity

Reset voltage 2,5 V max

Reset time 1 sec

Dimensions 10 cm Ø, H = 5 cm

Ordering Information

57º C fixed and rate-of-rise heat detectorDT713-557º C and R.O.R. heat detector, with relay outputDT713-5R10 cm diameter base - 6 terminalsDB702

Automatic Self Diagnostics : Dynamic full detector test,Sensitivity test

E

Manual Self Diagnostic routine with visual sensitivityindication

E

Field sensitivity testing without external metersE

Field exchangeable and disposable optical chamberE

High false alarm immunityE

Floating background with drift compensationE

Separate fire and trouble LEDE

12 - 24 V dc operationE

Polarity insensitiveE

Full range : optical, heat and optical/heat multi criteriasensor

E

EN 54 approvedE

Page 17: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 15

DT713-770º C fixed and R.O.R. heat detector

700 seriesThe smoke detector continually monitors its own sensitivity andoperational status. Once a day, it performs a full diagnostic test whichincludes dynamically testing the sensing chamber and internalelectronics.

Specifications

Operating voltage 8.5 - 33 V dc FWR

Current consumption

Quiescent at 24 V dc 100 A; Max. 70 A average

In alarm at 24 V dc 60 mA

Alarm indication Red LED

Fault indication Yellow LED

Remote alarm output 30 mA

RY contact rating 2 A @ 30 V dc;1 A @ 120 V ac

Humidity 0 - 95%; Non-condensing

IP rating IP 43

Heat specification

Max. 70º C ± 1.5º C

R.O.R. 8º C/min and > 40° C

Reset voltage 2,5 V max

Reset time 1 sec

Dimensions 10 cm Ø, H = 5 cm

Ordering Information

70º C fixed and R.O.R. heat detectorDT713-710 cm diameter base - 6 terminalsDB702

Automatic Self Diagnostics : Dynamic full detector test,Sensitivity test

E

Manual Self Diagnostic routine with visual sensitivityindication

E

Field sensitivity testing without external metersE

Field exchangeable and disposable optical chamberE

High false alarm immunityE

Floating background with drift compensationE

Separate fire and trouble LEDE

12 - 24 V dc operationE

Polarity insensitiveE

Full range : optical, heat and optical/heat multi criteriasensor

E

EN 54 approvedE

Page 18: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 16

DB70210 cm diameter base - 6 terminals

700 seriesDetector base for 700 series detectors

Ordering Information

10 cm diameter base - 6 terminalsDB70215 cm diameter base - 6 terminalsDB702U

Automatic Self Diagnostics : Dynamic full detector test,Sensitivity test

E

Manual Self Diagnostic routine with visual sensitivityindication

E

Field sensitivity testing without external metersE

Field exchangeable and disposable optical chamberE

High false alarm immunityE

Floating background with drift compensationE

Separate fire and trouble LEDE

12 - 24 V dc operationE

Polarity insensitiveE

Full range : optical, heat and optical/heat multi criteriasensor

E

EN 54 approvedE

Page 19: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 17

DI650Ionisation smoke detector

650 seriesThis elegant slim-line ionisation detector offers high performance andwide operating voltage

Specifications

Size of detector (mm)

Height 42

Diameter 100

Size of detector + base (mm)

Height 50

Diameter 100

Supply voltage 9 - 33 V dc

Quiescent Current at 24 V(typical)

28 A

Alarm indication LED

Normal operating temp. range(no icing)

-20 to + 60°C

Humidity (no condensation) 0-95% RH

Max. wind 10m/s

Remote alarm output current 17 mA

IP Rating 43

Ordering Information

Ionisation smoke detectorDI650Integrating ionisation smoke dectectorDI651Standard BaseDB860

Wide operating voltageE

Advanced electronic technologyE

Flashing LED optionE

Polarity insensitiveE

Common baseE

Elegant slim-line designE

EN54 approvedE

Magnetic test switch optionE

Proven detection performanceE

Page 20: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 18

DP652Optical smoke detector

650 seriesThis elegant slim-line optical sensor provides high performance andwide operating range.

Specifications

Size of detector (mm)

Height 42

Diameter 100

Size of detector + base (mm)

Height 50

Diameter 100

Supply voltage 9 - 33 V dc

Quiescent Current at 24 V(typical)

40 A

Alarm indication LED

Normal operating temp. range(no icing)

-20 to + 60°C

Humidity (no condensation) 0-95% RH

Max. wind Not affected

Remote alarm output current 17 mA

IP Rating 43

Ordering Information

Optical smoke detectorDP652Standard BaseDB860

Polarity insensitiveE

Common baseE

Elegant slim-line designE

EN 54 approvedE

Wide operating voltageE

Page 21: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 19

DT654Heat detector, R.O.R., 57º C A1R

650 seriesThis elegant slim-line heat sensor has a wide operating temperatureand is available in four ranges

Specifications

Size of detector (mm)

Height 42

Diameter 100

Size of detector + base (mm)

Height 50

Diameter 100

Supply voltage 9 - 33 V dc

Quiescent Current at 24 V(typical)

45 A

Alarm indication LED

Normal operating temp. range(no icing)

-20 to + 60°C

Humidity (no condensation) 0-95% RH

Max. wind Not affected

Remote alarm output current 17 mA

IP Rating 54

Ordering Information

Heat detector, R.O.R., 57º C A1RDT654Heat detector, 75º C BRDT655Heat detector, 95º C CRDT656Heat detector, 90º C CSDT657Standard BaseDB860

Wide operating voltageE

Advanced electronic technologyE

Flashing LED optionE

Polarity insensitiveE

Common baseE

Elegant slim-line designE

EN54 approvedE

Magnetic test switch optionE

Proven detection performanceE

Page 22: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 20

DB860Standard Base

650 seriesThe base has been designed to enable detectors to be plugged inwithout any need for force - particularly useful when fitting tosuspended ceilings.

Ordering Information

Standard BaseDB860Standard base 15 cm diameterDB860U

860 series Conventional fire detectorsE

Polarity insensitiveE

Common baseE

Elegant slim-line designE

EN 54 approvedE

DB861Backplate for Ingress Protection 860-950

Ordering Information

Backplate for Ingress Protection 860-950DB861

Can prevent most ingress into the base and detectorE

Page 23: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 21

DB806Conduit box for 860 / 950 series bases

An inexpensive and versatile accessory for surface mounting 860 and950 series bases

Ordering Information

Conduit box for 860 / 950 series basesDB806

DB650650 series relay base

650 seriesThe relay base provides a volt-free contact for use in 4 wire controlsystems, and other applications

Ordering Information

650 series relay baseDB650

DB650E

For use with 4 wire control systemsE

Automatic door closersE

Volt-free relay contactsE

Page 24: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 22

DI1552Ionisation Sensor

The 1500 Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the system, without compromisingdetection speed. All sensors are compatible with a standard base thatmakes them easily interchangeable and support the connection of aremote indicator.

Specifications

Operating voltage 22 to 38 VDC

Current consumption

Quiescent @ 38 VDC 200 A

In Alarm < 11 mA

Alarm indication (Dual LED) White OFF - Red ON

Remote Alarm Output Available

Environment

Storage Temperature -10 to +70 °C

Operating Temperature -10 to +60 °C

Humidity (non-condensing) 0-95%

IP rating IP42

Radioactive Source 0.33 ± 0.04 Ci Am 241

Dimensions (h x Ø) 45 x 99 mm

Ordering Information

Ionisation SensorDI1552 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolatorKZ705IAnalogue fire detector base with isolator and sounderKZ705IAS Low current remote LED indicatorPA25/3L

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Dualsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 25: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 23

DP1561Optical sensor with field exchangeable optical block

The 1500 series detectors use a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the system, without compromisingdetection speed.

All sensors are compatible with a standard base that makes themeasily interchangeable and support the connection of the PA25/3Lremote indicator.

Specifications

Operating voltage 22 to 38 VDC

Current consumption

Quiescent @ 38 VDC 350 A

In Alarm < 11 mA

Alarm indication (Dual LED) Red

Remote Alarm Output Available

Environment

Storage Temperature -10 to +70 °C

Operating Temperature -10 to +60 °C

Humidity (non-condensing) 0-95%

IP rating IP42

Radioactive Source NA

Dimensions (h x Ø) 45 x 99 mm

Ordering Information

Optical sensor with field exchangeable optical blockDP1561 Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolatorKZ705IAnalogue fire detector base with isolator and sounderKZ705IAS Low current remote LED indicatorPA25/3L

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Dualsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 26: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 24

DP1551TDual Sensor (Optical/Heat)

The 1500 Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the system, without compromisingdetection speed. All sensors are compatible with a standard base thatmakes them easily interchangeable and support the connection ofaremote indicator.

Specifications

Operating voltage 22 to 38 VDC

Current consumption

Quiescent @ 38 VDC 350 A

In Alarm < 5 mA

Alarm indication (Dual LED) Red

Remote Alarm Output Available

Environment

Storage Temperature -10 to +70 °C

Operating Temperature -10 to +70 °C

Humidity (non-condensing) 0-95%

IP rating IP42

Radioactive Source NA

Dimensions (h x Ø) 51 x 99 mm

Ordering Information

Dual Sensor (Optical/Heat)DP1551T Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolatorKZ705IAnalogue fire detector base with isolator and sounderKZ705IAS Low current remote LED indicatorPA25/3L

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Dualsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 27: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 25

DT1553Heat Sensor

The 1500 Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the system, without compromisingdetection speed. All sensors are compatible with a standard base thatmakes them easily interchangeable and support the connection ofaremote indicator.

Specifications

Operating voltage 22 to 38 VDC

Current consumption

Quiescent @ 38 VDC 250 A

In Alarm < 11 mA

Alarm indication (Dual LED) White OFF - Red ON

Remote Alarm Output Available

Environment

Storage Temperature -10 to +80 °C

Operating Temperature -10 to +70 °C

Humidity (non-condensing) 0-95%

IP rating IP42

Radioactive Source NA

Dimensions (h x Ø) 45 x 99 mm

Ordering Information

Heat SensorDT1553 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolatorKZ705IAnalogue fire detector base with isolator and sounderKZ705IAS Low current remote LED indicatorPA25/3L

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Dualsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 28: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 26

PG700Fire sensor programmer

The PG700 is a handheld device programmer and tester for theKL700A/Dx1500 series detectors. It is battery operated and allows theinstaller to perform installation tasks (such as device addressing) andmaintenance tasks (such as device calibration) in the field withoutexternal assistance.

Specifications

Supply 2 x 9 V batteries

Dimensions (w x h x d) 104 x 195 x 63 mm

Ordering Information

Fire sensor programmerPG700

Easy to useE

Battery operatedE

4 User selectable programs-Device analogue value-Change Device Address-Sequential device addressing-KL731A Calibration

E

Page 29: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 27

KZ705IAnalogue fire detector base with isolator

The KZ705I is a detector base with built in isolator for use with theKL700A/Dx1500 series detectors from GE-Interlogix. The isolatorprotects the loop from short circuit conditions. A LED on the side of thebase indicates the status of the isolator.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage 17 - 34 V

Current Consumption 50 A

Isolation Current 6 mA

Isolation Resistance 140 Mohm

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

Ordering Information

Analogue fire detector base with isolatorKZ705I

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in isolatorE

Page 30: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 28

KZ705ASAnalogue fire detector base with sounder

The KZ705AS is a detector base with built in analogue addressablesounder for use with the KL700A/Dx1500 series detectors fromGE-Interlogix. The sounder has its own address on the fire panel loopand works independent of the detector. It is fully controlled from thefire panel.

Specifications

Dimensions (Ø x h) 120 x 58 mm

Operating Voltage 22 - 38 V

Current Consumption 300 A Quiescent

Isolation Current -

Isolation Resistance -

Sounder Frequency 1 kHz (Continuous)

Sound Output

@ 3 mA 85 dBA

@ 5 mA 90 dBA

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

IP Rating IP21c

Ordering Information

Analogue fire detector base with sounderKZ705AS

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in sounderE

Up to 90 dBA sound outputE

Low current consumptionE

Page 31: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 29

KZ705IASAnalogue fire detector base with isolator and sounder

The KZ705IAS is a detector base with built in analogue addressablesounder and isolator for use with the KL700A/Dx1500 series detectorsfrom GE-Interlogix. The sounder has its own address on the fire panelloop and works independent of the detector. It is fully controlled fromthe fire panel. The isolator protects the loop from short circuitconditions.

Specifications

Dimensions (Ø x h) 120 x 58 mm

Operating Voltage 22 - 38 V

Current Consumption 350 A Quiescent

Isolation Current 6 mA

Isolation Resistance 140 Mohm

Sounder Frequency 1 kHz (Continuous)

Sound Output

@ 3 mA 85 dBA

@ 5 mA 90 dBA

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

IP Rating IP21c

Ordering Information

Analogue fire detector base with isolator and sounderKZ705IAS

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in sounderE

Up to 90 dBA sound outputE

Low current consumptionE

Built in isolatorE

Page 32: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 30

KAL410Conventional Zone Monitor Unit - 1 Zone

Allows the connection of one conventional zone to the analogue firesystem loop. This zone is constantly monitored. Up to 20 conventionaldevices may be connected to this zone.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 90 A

Quiescent @ 35 V 105 A

Alarm < 3 mA

Aux. supply (24 VDC)quiescent

200 A + equip

Aux. supply (24 VDC) alarm < 85 mA

End-of-line resistor 4.7 kohm

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Conventional Zone Monitor Unit - 1 ZoneKAL410

Easy numeric addressingE

Continuous supervision of the conventional zonesE

Surface mountE

Local alarm indicationE

Externally or loop poweredE

Aesthetically pleasingE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 33: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 31

KAL414CConventional Zone Monitor Unit - 4 Zones

Allows the connection of four conventional zones to the analogue firesystem loop. These zones are constantly monitored. Up to 20conventional devices may be connected to any zone.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 5 mA

Aux. Supply (24V DC)Quiescent

200 A + equip

Aux. Supply (24V DC) Alarm < 360 mA

End-of-line resistor 4.7 kOhm

Relay contact rating NA

Environmental

Storage temperature -10 to +50°C

Operating temperature -10 to +70°C

Relative humidity(non-condensing)

0-95 %

Dimensions (l x w x h) 163 x 107 x 36 mm

Ordering Information

Conventional Zone Monitor Unit - 4 ZonesKAL414C

Easy numeric addressingE

Continuous supervision of the conventional zonesE

Surface mountE

Local alarm indicationE

Externally poweredE

Aesthetically pleasingE

Part of a family of I/O modules consisting of:E

- Conventional Zone MonitorsE

- Digital Input ModulesE

- Extinguishing Control ModulesE

- Isolator ModulesE

- Manual Call PointsE

- Output UnitsE

- Retention UnitsE

- Supervised Output Units for sounder controlE

Page 34: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 32

KAL426CExtinguishing Control Module

The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL426 allows for the connection andcontrol of one extinguishing area to the addressable fire panel loop.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 210 A

Alarm < 10 mA

Aux. supply (24 VDC)quiescent

120 mA

Aux. supply (24 VDC) alarm < 1 A

End-of-line resistor 4.7 kOhm

Relay contact rating 2½ A

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 163 x 107 x 36 mm

Ordering Information

Extinguishing Control ModuleKAL426C

Aesthetically pleasingE

Easy numeric addressingE

Externally poweredE

Supervised I/OE

Surface mountE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 35: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 33

KAL430Relay Module - 1 Relay

Provides for one potential free relay output for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The output may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 70 A

Quiescent @ 35 V 100 A

Alarm < 3.5 mA

Aux. 24 VDC quiescent 22 mA

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating 2½A @ 250 VAC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Relay Module - 1 RelayKAL430

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 36: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 34

KAL434CAddressable Relay Module - 4 Relays

Provides for four potential free relay outputs for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The outputs may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. 24VDC Quiescent 100 A

Aux. 24VDC Alarm 10 mA

End-of-line resistor NA

Relay contact rating 2½A @ 250 VAC

Environmental

Storage temperature -10 to +50°C

Operating temperature -10 to +70°C

Relative humidity (non-cond.) 0-95 %

Dimensions (l x w x h) 163 x 107 x 36 mm

Ordering Information

Addressable Relay Module - 4 RelaysKAL434C

Easy numeric addressingE

Externally poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of a family of I/O modules consiting of:E

- Conventional Zone MonitorsE

- Digital Input ModulesE

- Extinguishing Control ModulesE

- Isolator ModulesE

- Manual Call PointsE

- Output UnitsE

- Retention UnitsE

- Supervised Output Units for sounder controlE

Page 37: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 35

KAL440Supervised Relay Module

Allows for the supervision of a single, 24 Volt powered output contacton the fire system loop. This unit may be used to control for e.g.sounders in case of fire conditions, but may also be used to switch anyoutput considered crucial enough to have the cable integrity betweenthe unit and the switch point monitored.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 3.6 mA

Aux. 24 VDC quiescent 23 mA

Aux. 24 VDC alarm 23 mA + equip

End-of-line resistor 4.7 kohm

Relay contact rating 1¼ A @ 250 VAC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Supervised Relay ModuleKAL440

Easy numeric addressingE

Externally poweredE

Supervised 24 VDC Output E

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 38: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 36

KAL450Addressable Manual Call Point

The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL450 is an addressable manual callpoint for manual fire activation.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 90 A

Quiescent @ 35 V 120 A

Alarm < 3.5 mA

Aux. supply (24 VDC)quiescent

NA

Aux. supply (24 VDC) alarm NA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +70°C

Operating temperature -10 °C to +50°C

Relative humidity 95 % (non condensing)

Ingress Protection IP20

Dimensions (L x W x H) 87 x 87 x 20 mm

Weight 98 g

Ordering Information

Addressable Manual Call PointKAL450EN54 universal glass for manual call pointDM715Terminal tray for MCPDM780GS cardDM781Hinged transparent MCP protection coverDM782BZB black bezelDM783Test keyDM784Spacer box, redDM785Surface mounting box with connectors, redDM787Surface mount box without connectors, redDM788Flush mount cradle with connectorsDM790Flush mount cradle, connectors & forkgripsDM795Breakable seal for MCPDM798Terminal tray ETT/3 with bezel 3DM799Resettable element for MCP DM700/KAL450DM800

Easy numeric addressingE

Loop poweredE

Local test facilityE

Surface or flush mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Wide range of accessoriesE

Page 39: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 37

KAL460Digital Input Module

Provides a remote input to the fire system loop. The input is constantlymonitored and its status communicated to the fire control panel. Theinput may be activated by closing or opening a potential free contact,depending on the module configuration.

This module may be used to monitor any contact by showing its statusthrough the fire control panel e.g. the monitoring of pressureequipment and closure fire break doors.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 10 mA

Aux. 24 VDC quiescent 200 A

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Digital Input ModuleKAL460

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 40: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 38

KAL470Isolator Module

The 400 series modules consist of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL470 is an isolator module in thisseries that isolates the faulty zone on a fire panel loop during shortcircuit conditions. The KAL470 does not use an address on the loop.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. supply (24 VDC)quiescent

NA

Aux. supply (24 VDC) alarm NA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +50°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 75 x 45 x 28 mm

Ordering Information

Isolator ModuleKAL470

Requires no device addressE

Automatic resetE

Local status indicationE

Surface mountE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 41: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 39

KAL490Retention Module - 1 Input / 1 Output

Provides a remote input and a potential free voltage relay output tothe fire system loop. The input signal is constantly monitored and itsstatus displayed on the control panel, whilst the output is fail-to-safe.Auxiliary supply monitoring is also included.

The module is used to for e.g. control and monitor doors such as firebreak doors. The relay provides the door activation and the inputmonitors the door status.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. 24 VDC quiescent 200 A

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating 1A @ 30 VAC/VDC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Retention Module - 1 Input / 1 OutputKAL490

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 42: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 40

DP2051Optical Sensor

2000 SeriesEquipped with a field-exchangeable optical block and has fullcertification, this optical sensor provides good looks as well as topfeatures

Specifications

Operating voltage 17 - 28 V dc

Current consumption at 24 V dc

Quiescent < 150 A

Alarm LED: 2 mA - 7-segment: 2 mA

Alarm indication White LED (red alarm)

Remote alarm output

DP2051 / DT2053 -

DP2061 / DT2063 4 mA

DP2071 / DT2073 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10°C - 70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

Optical SensorDP20512000 series base, 2 terminalsDB2001Isolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 43: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 41

DP2061Optical Sensor with remote LED output

The DP2061 is equipped with a field-exchangeable optical block andhas full certification. This optical sensor combines good looks withalarm and fault LEDs as well as a remote output.

Specifications

Operating voltage 17 - 28 VDC

Current consumption @ 24 VDC

Quiescent < 150 A

Alarm 2 mA

Alarm indication White LED (Red alarm)

Remote alarm output 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10 to +70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

Optical Sensor with remote LED outputDP2061 2000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002UIsolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range of detectors availableE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 44: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 42

DP2061TOptical and heat multi-sensor with remote LED output

The DP2061T multi-sensor combines the smoke sensitivity of an opticalsmoke detector with the enhancement of heat sensing. Being able tooperate in five modes, the DP2061T multi sensor can operate as anoptical smoke sensor enhanced by heat detection (with two differentsmoke sensitivities), as a dual smoke and heat detector, each sensoroperating independently, an optical sensor only, or a heat detectoronly.

Specifications

Operating voltage 17 to 28 VDC

Current consumption @ 24 VDC

Quiescent < 150 uA

Alarm 2 mA

Alarm indication White LED (Red alarm)

Remote alarm output 4mA

Humidity 0 - 95% non condensing

Operating temperature -10°C to 70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

Optical and heat multi-sensor with remote LED outputDP2061T 2000 series base, 2 terminalsDB20012000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002U2000 series deep base, 4 terminalsDB2004Isolating baseDB2016 Optical Remote IndicatorAI672Optical and Accustical Remote IndicatorAI673

Optical smoke and heat detectionE

Five modes of operation: multisensor (2 sensitivities) ,dual sensor, or independant smoke and heat

E

Independant control of detector modesE

Optical sensor with field exchangeable optical chamberE

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Remote test capabilitiesE

Remote signalling capabilitiesE

Polarity insensitiveE

Full range of sensors: optical and heatE

Full range of I/0 units, MCPs and accessoriesE

Isolator base optionE

Page 45: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 43

DP2071Optical Sensor with 7-segment display

2000 SeriesEquipped with a field-exchangeable optical block and with fullcertification, this optical sensor provides good looks as well as topfeatures. Fitted with an exclusive 7-segment display, the sensorprovides comprehensive information. In addition to alarm signalling,information such as Fault, Pre-alarm, Maintenance Alarm (Clean me),Disabled Sensor, Sensor in Test, Error (double address, wrong sensortype) and Sensor Polled is provided.

Specifications

Operating voltage 17 - 28 V dc

Current consumption at 24 V dc

Quiescent < 150 A

Alarm LED: 2 mA - 7-segment: 2 mA

Alarm indication White LED (red alarm)

Remote alarm output 4 mA

DP2051 / DT2053 -

DP2061 / DT2063 4 mA

DP2071 / DT2073 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10°C - 70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

Optical Sensor with 7-segment displayDP20712000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002UIsolating baseDB2016

7-segment displayE

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Page 46: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 44

DT20532000 Series heat sensor

2000 seriesFully certified, this heat sensor provides good looks as well as topfeatures.

Specifications

Operating voltage 17 - 28 V dc

Current consumption at 24 V dc

Quiescent < 150 A

Alarm LED: 2 mA - 7-segment: 2 mA

Alarm indication Red LED

Remote alarm output

DP2051 / DT2053 -

DP2061 / DT2063 4 mA

DP2071 / DT2073 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10°C - 70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

2000 Series heat sensorDT20532000 series base, 2 terminalsDB2001Isolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 47: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 45

DT20632000 series heat sensor with remote LED output

2000 SeriesFully certified, this heat sensor provides good looks as well as topfeatures. Dual LED's indicate both alarm and fault. A remote output isalso provided.

Specifications

Operating voltage 17 - 28 VDC

Current consumption @ 24 VDC

Quiescent < 150 A

Alarm LED: 2 mA - 7-segment: 2 mA

Alarm indication Red LED

Remote alarm output 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10 to +70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

2000 series heat sensor with remote LED outputDT2063 2000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002UIsolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 48: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 46

DT2073Heat Sensor with 7-segment Display and Remote LED Output

2000 SeriesFitted with an exclusive 7-segment display, this detector providescomprehensive, on the spot information. In addition to alarm signalling,information such as Fault, Pre-alarm, Maintenance Alarm (Clean me),Disabled Sensor, Sensor in Test, Error (double address, wrong sensortype) and Sensor Polled is provided.

Specifications

Operating voltage 17 - 28 V dc

Current consumption at 24 V dc

Quiescent < 150 A

Alarm LED: 2 mA - 7-segment: 2 mA

Alarm indication Red LED

Remote alarm output

DP2051 / DT2053 -

DP2061 / DT2063 4 mA

DP2071 / DT2073 4 mA

Humidity 0 - 95% non condensing

Operating temperature -10°C - 70°C

IP rating IP43

Dimensions

Height 5 cm

Diameter 10 cm

Ordering Information

Heat Sensor with 7-segment Display and Remote LED OutputDT20732000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002UIsolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 49: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 47

DB20012000 series base, 2 terminals

2000 series2 terminal base for DP2051 and DT2053

Ordering Information

2000 series base, 2 terminalsDB2001

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 50: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 48

DB20022000 series base, 4 terminals

2000 seriesA four terminal base for all 2000 series detectors

Ordering Information

2000 series base, 4 terminalsDB2002Standard Base 15 cm, 4 TerminalsDB2002U

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 51: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 49

DB2016Isolating base

The DB2016 isolator base senses and isolates short circuit faults. Ayellow LED indicates a short circuit condition. The detector in the basewill still receive power in the event of a single short circuit. If everydetector is fitted with an isolator base then no device will be lost in theevent of a single short circuit.

Ordering Information

Isolating baseDB2016

Remote test capabilitiesE

Remote signalling capabilitiesE

Optical sensor with field exchangeable optical chamberE

Available in one LED, two LED and seven segmentdisplay

E

Easy numeric addressing (1-128)E

Enhanced communication protocolE

Full diagnostic self testingE

Polarity insensitiveE

Full range: optical and heatE

Full range of I/0 units and accessoriesE

Isolator baseE

EN54 approvedE

VdS approvedE

Page 52: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 50

IU2016Loop Isolator

2000 seriesThe Aritech Loop Isolator is designed to prevent an entirecommunication loop from being disabled in the event of a short circuit.The IU 2016 isolates that part of the loop containing the short from theremainder of the circuit.

Specifications

Operating voltage 17 - 28 V, comm. loop terminals

Total standby current < 250 A

Isolated current

Average < 1.6 mA

Transition pulse < 36 mA (5 ms duration)

Operating temperature -10º C to 70º C

Operating humidity range 0 - 95%; Non-condensing

Line resistance

Normal 0.55 Ohms

Isolated > 33K Ohms

Switching voltage

Normal to isolated 13.8 V dc

Isolated to normal 2.5 V dc

Switching time

Normal to isolated < 5 ms

Isolated to normal < 0.5 ms (after fault correction)

Ordering Information

Loop IsolatorIU2016Base for the IU2016 isolatorDB2003

Complete isolation of loop short circuitE

Automatic restore when fault is correctedE

Module LED indicates location of faultE

Page 53: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 51

DB2003Base for the IU2016 isolator

Ordering Information

Base for the IU2016 isolatorDB2003

Page 54: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 52

DM2000Manual call point, flying leads

2000 seriesThe DM 2000 is a break glass design call point with a high strengthplastic housing. The LED indicator provides visual confirmation of alarminitiation. The test key (included with each unit) facilitates functionaltesting of the call point.

Specifications

Operating voltage 17 - 28 V, @ comm.loop terminals

Voltage modulation 4 - 9 V dc

Standby current < 250 A

LED indicator current 2.5 mA maximum

Operating temperature -10º C to 70º C

Operating humidity 0 - 95%; Non-condensing

Dimensions (L x W x H)

Flush mount 87 x 87 x 24 mm

Surface mount 87 x 87 x 56 mm

Ordering Information

Manual call point, flying leadsDM2000Manual call point flying leads - YellowDM2000YManual call point flying leads - BlueDM2000BBreak glass, EN54, Aritech logoDM711EN54 universal glass for manual call pointDM715

Analogue addressable manual call pointE

LED alarm indicatorE

Tamper resistant break glass designE

Easy to test with self resetE

Fast responseE

IP67 waterproof model availableE

Page 55: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 53

DM2000EManual call point - Red IP67 waterproof, including backbox

2000 seriesThe DM 2000E is a break glass design call point with a high strengthplastic housing and IP67 waterproof. The LED indicator provides visualconfirmation of alarm initiation. The test key (included with each unit)facilitates functional testing of the call point.

Specifications

Operating voltage 17 - 28 V, @ comm.loop terminals

Voltage modulation 4 - 9 V dc

Standby current < 250 A

LED indicator current 2.5 mA maximum

Operating temperature -10º C to 70º C

Operating humidity 0 - 95%; Non-condensing

Dimensions (L x W x H)

Flush mount 87 x 87 x 24 mm

Surface mount 87 x 87 x 56 mm

Ordering Information

Manual call point - Red IP67 waterproof, including backboxDM2000EBreak glass, EN54, Aritech logoDM711EN54 universal glass for manual call pointDM715 Analogue addressable manual call pointE

LED alarm indicatorE

Tamper resistant break glass designE

Easy to test with self resetE

Fast responseE

IP67 waterproof model availableE

Page 56: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 54

IO2014Input Output unit - 4 inputs

The 2000 Series loop powered Input/Output modules are designed toprovide unlimited applications to input monitoring and outputswitching. These modules, combined with the powerful features of the2000/1200 Series fire panels gives the user total versatility.

The IO2014 is a unit that provides 4 inputs with selectable linesupervision.

Specifications

Operating voltage 17 - 39 VDC

Total standby current < 420 A

Typical standby current < 350 A

Operating temperature -10°C to +70°C

Operating humidity range 0 - 95%, Non-condensing

Outputs NA

Inputs 4 Supervision Selectable

33 k resistor in series withswitch

Normal, Active, Open, Short

No resistor in series withswitch

Open, Short

EOL resistor 150 k , ¼ W, 5%

Ordering Information

Input Output unit - 4 inputsIO2014

Wide range of I/O Modules : 2 input-1 output / 2 input-2output / 4 input / 4 input - 4 output

E

Versatile input structureE

Supervised inputsE

Normally Open/Normally Closed operationE

Magnetic latched output relaysE

Loop poweredE

No external power requiredE

Easy numeric addressingE

Page 57: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 55

IU2050Single Input Module

2000 seriesThe Aritech Analogue Addressable Single Input Module is designed foruse with the FP 2000 Fire Panel to monitor normally open or normallyclosedcontacts. It can typically be connected to conventional Manual CallPoints, Pull Stations or Door Monitors and will report actuation within 1seconddepending on the programming of the fire panel.

Specifications

Operating voltage 17 - 28 V, @ comm. loop terminals

Voltage modulation 4-9 V dc

Standby current < 250 A

Operating temperature -20° C to 70° C

Operating humidity 0 - 95%; Non-condensing

EOL resistor 150 K, 1/4 W, 5%

Ordering Information

Single Input ModuleIU2050

Analogue Addressable Single Input ModuleE

Loop PoweredE

Supervised InputE

Page 58: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 56

IU2055Conventional Zone Monitor

The IU2055 two-wire zone monitor is designed to provide an interfacebetween conventional smoke detectors and the addressable series2000/1200 fire panels. The IU2055 enables the adressable panel tomonitor the presence and operation of up to 30 conventional detectorsin standard operation mode, or up to 20 intrinsically safe series 870conventional detectors in intrinscally safe configurations.

Specifications

Operating voltage

At loop terminals 18 - 39 VDC

At zone output terminals 14 - 18.5 VDC

Operating current

Standby < 15 mA

Alarm < 35 mA

Remote LED 4.5 mA

Maximum zone load current 3.5 mA

Maximum zone capacitance < 1 F

Maximum zone resistance < 30 Ohm

Operating temperature -10° C to +70° C

Operating humidity range 0 - 95%; Non-condensing

End of line resistance 4.3 k Ohm, ¼ W, 5 %

Zone impedances @ 24 V

Short circuit < 30 Ohms

Fire 180 - 300 Ohms

Quiescent 2.7 - 4.3 K Ohms

Open > 15 K Ohms

Ordering Information

Conventional Zone MonitorIU2055

Monitors up to 30 conventional smoke detectorsE

Zone supervised for open and short circuitsE

Supports alarm verification and reset functionsE

Loop poweredE

Easy numeric addressingE

Supports intrinsically safe applications for up to 20series 870 detectors

E

Page 59: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 57

GBX2000Galvanic barrier

2000 seriesA Galvanic barrier used with IU2055 zone monitor unit in intrinsic safeapplications

Ordering Information

Galvanic barrierGBX2000

Approved with the IU2055 zone monitor unitE

Intrinsic safe operation when correctly installedE

IU2080Indicating Circuit Controller

2000 seriesThe Aritech Indicating Circuit Controller is designed for efficient,addressable control of sounders, bells and strobes in a fire detectionsystem. The 3 A of output power available from the IU 2080 assuresmeeting all requirements for signaling devices on a fire alarm system.

Specifications

Operating voltage 17-28 V, at comm. loop terminals

Total standby current <350 A, <200 A typical

Maximum alarm current <3.5 mA at comm. loop

Operating temperature -10º C to 70º C

Operating humidity range 0 - 95%; Non-condensing

Circuit impedance at 24 V

Short circuit <3.3 K

Quiescent 3.3 K - 13 K

Open circuit <13 K

Power supply low voltagedetection

24 V; <20.4 V

Standby current <11 mA @ 24 V dc

Alarm current <72 mA @ 24 V dc (plus output circuit loadcurrent from ext. power supply)

Supervisory voltage 2.2 V dc, inverted

Circuit voltage in alarm 24 V dc

Alarm current (fuse rating) 3 A

End of line resistor value 10 K, 1/4W, 5%

Ordering Information

Indicating Circuit ControllerIU2080

Versatile, addressable control for sounders, bells andstrobes

E

Supervised output circuitE

Programmable outputE

24 V external power supplyE

Page 60: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 58

FD2705R2000 series addressable reflective beam detector 5 - 50m

2000 seriesThe FD 2705R and FD 2710R provides an integral, loop poweredanalogue addressable reflective beam detector up to 100m distance. It operates with 2000 series protocol with the FP1200 / 2000 Firepanels

Specifications

Supply voltage 17 - 30 V dc

Range

FD 2705R 5 - 50 m

FD 2710R 50 - 100 m

Lateral detection 7.5 m

Current consumption

Quiescent 5 mA

Alarm 9 mA

Fault 5 mA

Optical wave length 880 nm

Operating temperature -30°C to 55°C

Size 210 x 130 x 120 mm

IP rating IP50

Construction Flame retardent ABS

Colour Gray-black

Ordering Information

2000 series addressable reflective beam detector 5 - 50mFD2705R2000 series addressable reflective beam detector 50 - 100mFD2710R

Loop PoweredE

2000 series protocolE

Area coverage up to 600 m 2 per unitE

Range from 5 - 50 m and 50 - 100 mE

Up to ceiling heights of 25 mE

Low current consumptionE

3 selectable alarm thresholdsE

Self check and automatic contamination compensationE

Automatic discrimination between fire and faultE

Retro operation through prismE

Vertical or horizontal mountE

Easy wiring and unique alignmentE

Microprocessor controlledE

Conforms to BS 5839 part 5 and EN54E

Page 61: Aritech Master Fire Product Catalogue (06.12.05)

Warning Device

Page : 59

AS20152000 series loop powered sounder

2000 seriesThe AS2015 is a 2000 series addressable loop powered sounder for theFP1200 and FP2000 range of fire panels. The unit has a built in isolatorand can be synchronized.

Specifications

Operating voltage 17-39 VDC

Supply current

not activated 240 A

activated 3mA

Sound output @ 1 meter 100 dB(A)

Continuous tone 990 Hz

Intermittent tone 990 Hz, On Off @ 1 Hz

Two tone 990 Hz / 650 Hz @ 1 Hz

Ordering Information

2000 series loop powered sounderAS20152000 series loop powered sounder - whiteAS2015W

Loop poweredE

Low currentE

High outputE

Built in isolatorsE

3 tonesE

FP1200 / 2000 fire panel operationE

Page 62: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 60

DI950Analogue addressable ionisation sensor

950 seriesThis elegant slim-line ionisation sensor provides high-performancesmoke detection

Specifications

Supply voltage (V dc) 17-28

Quiescent current 280 A

Alarm indication Red LED

Alarm LED current 2 mA

Normal operating temperature(no icing)

-20º to +60º C

Rel. humidity (no condensation) 0-95 %

Max. wind (continuous) 10 m/s

Size of device in base (H x Ø mm) 50 x 100

Ordering Information

Analogue addressable ionisation sensorDI950

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DP951Optical sensor

950 seriesThis elegant slim-line optical sensor provides high performanceanalogue addressable features

Specifications

Supply voltage (V dc) 17-28

Quiescent current 340 A

Alarm indication Clear LED (red in alarm)

Alarm LED current 4 mA

Normal operating temperature(no icing)

-20º to +60º C

Rel. humidity (no condensation) 0-95 %

Max. wind (continuous) Not affected

Size of device in base (H x Ø mm) 50 x 100

Ordering Information

Optical sensorDP951950 series standard baseDB950

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

Page 63: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 61

DT952Analogue addressable temperature sensor

950 seriesThis elegant slim-line analogue addressable heat sensor providesexact temperature information to the fire panel.

Specifications

Supply voltage (V dc) 17-28

Quiescent current 250 A

Alarm indication Red LED

Alarm LED current 2 mA

Normal operating temperature(no icing)

-20º to +60º C

Rel. humidity (no condensation) 0-95 %

Max. wind (continuous) Not affected in fixed temp. use

Size of device in base (H x Ø mm) 50 x 100

Ordering Information

Analogue addressable temperature sensorDT952950 series standard baseDB950

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DM960950 series analogue addressable manual callpoint

950 seriesA manual call point operating with 950 series protocol.

Ordering Information

950 series analogue addressable manual callpointDM960

Page 64: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 62

DI970Intrinsic safe analogue addressable ionisation detector

970 seriesAn intrinsic safe ionisation detector, when used with the PT971/2protocol simulator and GBX70 barrier

Ordering Information

Intrinsic safe analogue addressable ionisation detectorDI970Intrinsic safe protocol translatorPT971Dual channel IS protocol translatorPT972Galvanic barrier (single channel)GBX70Detector base for 970 series intrinsic safe sensorsDB970

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DP971Intrinsic safe optical detector

970 seriesAn intrinsic safe optical detector, when used with the PT971/2 protocoltranslator and GBX70 barrier

Ordering Information

Intrisic safe optical detectorDP971Intrinsic safe protocol translatorPT971Dual channel IS protocol translatorPT972Galvanic barrier (single channel)GBX70Detector base for 970 series intrinsic safe sensorsDB970

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

Page 65: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 63

DT972Intrinsic safe heat detector

970 seriesAn intrinsic safe heat detector, when used with the PT971/2 protocoltranslator and GBX70 barrier

Ordering Information

Intrinsic safe heat detectorDT972Intrinsic safe protocol translatorPT971Dual channel IS protocol translatorPT972Galvanic barrier (single channel)GBX70Detector base for 970 series intrinsic safe sensorsDB970

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DM970Intrinsic safe manual call point

970 seriesAn intrinsic safe manual call point, when used with the PT971/2protocol translator and GBX70 barrier.

Ordering Information

Intrinsic safe manual call pointDM970

Page 66: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 64

PT971Intrinsic safe protocol translator

970 seriesA protocol translator for the 970 series analogue addressable intrinsicsafe sensors. This must be used with the GBX70 barrier

Ordering Information

Intrinsic safe protocol translatorPT971Dual channel IS protocol translatorPT972

GBX70Galvanic barrier (single channel)

970 serisA galvanic barrier used in 970 series intrinsic safe applications. TheGBX70 is used in conjuntion with the PT971 and PT972 protocoltranslators.

Ordering Information

Galvanic barrier (single channel)GBX70

Page 67: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 65

II950950 series mini switch monitor unit

950 seriesThis unit is designed to monitor the state of one or more single poleswitches connected on a single pair of cables.

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 1 mA

Alarm -

Led /relay on 3.5 mA

Switch on surge 3 mA

Switch monitoring 9-11 Vdc

Relay contact rating -

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series mini switch monitor unitII950II950I

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

II952950 series switch monitor unit - surface mount

950 seriesThis unit is designed to monitor the state of one or more single poleswitches connected on a single pair of cables. The circuit will reportopen and short-circuit faults.

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 730 A

Alarm

Led /relay on 5.6 mA

Switch on surge 2.5 mA

Switch monitoring 9-11 Vdc

Relay contact rating -

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series switch monitor unit - surface mountII952Switch monitor unit plus - surface mountII953

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

Page 68: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 66

II955950 series zone monitor unit - surface mount

950 seriesThe zone monitor powers and controls the operation of a zone ofconventional detectors.

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 4 mA

Alarm 11-19 mA

Led /relay on -

Switch on surge 2.8 mA

Switch monitoring -

Relay contact rating -

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series zone monitor unit - surface mountII955

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

IO950950 series single channel IO - surface mount

950 seriesThis unit provides a loop-powered relay output, a monitored input andan un-monitored opto-coupled input. It can report fault, switch openand switch closed condition. It uses the standard housing.

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 1.2 mA

Alarm -

Led /relay on 6 mA

Switch on surge 3.5 mA

Switch monitoring 9-11 Vdc

Relay contact rating 1A@30 Vac/dc

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series single channel IO - surface mountIO950

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

Page 69: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 67

IO955950 series output unit - surface mount

950 seriesThis unit provides a loop-powered relay output

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 720 A

Alarm -

Led /relay on 3.3 mA

Switch on surge 3 mA

Switch monitoring -

Relay contact rating 1A@30 Vac/dc

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series output unit - surface mountIO955

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

IO956950 series sounder circuit controller - surface mount

950 seriesThis unit is designed to control a zone of sounders powered by anexternal DC supply.

Specifications

Supply voltage 14-28 Vdc

Current consumption

Quiescent (20kOhm) 1.9 mA

Alarm -

Led /relay on 1.7 mA

Switch on surge 2.6 mA

Switch monitoring 9-11 Vdc

Relay contact rating -

Operating temperature -20/+70°C

Relative humidity 0-95%

Ingress protection IP54

Ordering Information

950 series sounder circuit controller - surface mountIO956

Loop poweredE

Full line: Switch monitors, Zone monitors, Input/outputunit, Output unit, Sounder circuit controller

E

LEDs for signalling of I/O and fault conditionE

Aesthetically pleasingE

Page 70: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 68

IU950950 series loop isolator

Ordering Information

950 series loop isolatorIU950

Page 71: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 69

AS950950 series loop powered sounder

950 SeriesDesigned to operate with the 950 series analogue sensors andmonitors, the AS950 loop sounders are addressed and utilise the sameprotocol using a very low current.

Specifications

Supply voltage 14 - 28 V dc

Current consumption

Quiescent 140 A at 24 V dc

Switch on surge 1.24 mA for 3 sec.

Operated at 85 dBA 3 mA +/- 0.25 mA

Operated at 92 dBA 8 mA +/- 0.25 mA

Drive frequency 500 - 550 Hz (continuous mode)

Ingress protection IP43

Operating temperature -20 to 60 °C

Dimension (dia. x depth) 115 x 25 mm (sounder only)

115 x 33 mm (sounder with cap)Weight 140 g (sounder only)

145 g (sounder with cap)

Ordering Information

950 series loop powered sounderAS950Loop powered sounder, for use with isolator baseAS950ILoop powered sounder, white capAS950W

Loop poweredE

Low current consumptionE

Aritech 950 and Apollo protocol compatibleE

Continuous or pulsed toneE

Sound output 85 - 92 dBA at 1 metreE

Reduces wiring and installation costE

Page 72: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 70

AS955950 series high output loop powered sounder

950 SeriesDesigned to operate with the 950 series analogue sensors andmonitors, the AS955 high output loop sounders are addressed andutilise the same protocol using a very low current.

Specifications

Supply voltage 14 - 28 V dc

Current consumption

Quiescent 140 A at 24 V dc

Switch on surge 1.24 mA for 3 sec.

Operated 4.5 mA +/- 0.25 mA

Drive frequency 500 - 550 Hz (continuous mode)

Ingress protection IP43

Operating temperature -20 to 60 °C

Sound output 100 dB(A)

Ordering Information

950 series high output loop powered sounderAS955

Loop poweredE

Low current consumptionE

950 series protocolE

Continuous or pulsed toneE

Sound output 100 dB(A) at 1 metreE

Reduces wiring and installation costE

Page 73: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 71

FD950950 series loop-powered beam detector

950 SeriesA 950 series loop-powered beam detector with a range of up to 100mlong and 15m wide.

Ordering Information

950 series loop-powered beam detectorFD950

Loop-poweredE

950 series compatible with FP1200 and FP2000E

Four selectable alarm levelsE

Drift compensationE

Remote interfaceE

Simple wiringE

Simple alignmentE

Page 74: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 72

DB950950 series standard base

950 seriesA unique, patented addressing method provides simple, user-friendlyand accurate identification of monitor location whereby a coded card,inserted in the base, is read by any monitor as it is plugged in.

Ordering Information

950 series standard baseDB950

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DB951Base for IU 950

950 seriesThis base is required for the IU950 isolator

Ordering Information

Base for IU 950DB951

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

Page 75: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 73

DB961Isolating base (20 devices)

The isolating base senses and isolates short circuit faults on 950 seriesloops and spurs. Up to 20 devices may be placed between any twoisolator bases.

Ordering Information

Isolating base (20 devices)DB961

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

DB970Detector base for 970 series intrinsic safe sensors

Ordering Information

Detector base for 970 series intrinsic safe sensorsDB970

Passive base addressE

Programmable slide-in address cardE

Aesthetic designE

EN 54,BOSEC,VdS,CNBOP approvedE

Page 76: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 74

IU980Coded cards, addresses 1 - 18

950 seriesPrecoded Xpert address cards for use in DB9xx bases

Ordering Information

Coded cards, addresses 1 - 18IU980Coded cards, addresses 19 - 36IU981Coded cards addresses 37 - 54IU982Coded cards, addresses 55 - 72IU983Coded cards, addresses 73 - 90IU984Coded cards, addresses 91- 108IU985Coded cards, addresses 109 - 126IU986

Page 77: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 75

FP202Conventional fire alarm panel with 2 zones

The FP200 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Aritech Series 300, Series 650 andSeries 700 devices. The FP202 has 2 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 2 zonesFP202

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of ARITECH conventionaldetectors

E

Page 78: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 76

FP204Conventional fire alarm panel with 4 zones

The FP200 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Aritech Series 300, Series 650 andSeries 700 devices. The FP204 has 4 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 4 zonesFP204

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of ARITECH conventionaldetectors

E

Page 79: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 77

FP206Conventional fire alarm panel with 6 zones

The FP200 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Aritech Series 300, Series 650 andSeries 700 devices. The FP206 has 6 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 6 zonesFP206

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of ARITECH conventionaldetectors

E

Page 80: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 78

FP402Conventional fire alarm panel with 2 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Current Consumption (panel only)

Quiescent 75 mA

Alarm 162 mA

Batteries

Capacity 2 x 2.3 Ah

Fuse rating 2 A

Zone

Nominal Voltage 24 VDC

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 297 (w) x 307 (h) x 105 (d)

Weight (without batteries) 3.6 kg

Expansion Module Slots 1

Ordering Information

Conventional fire alarm panel with 2 zonesFP402 Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404Relay module, 4 supervised relays for NK700/Fx400 fire panelsSB404 Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACTSealed Lead-Acid Battery - 12V 2.2AhBS122N

Modern, attractive designE

Microprocessor controlledE

From 2 up to 16 zonesE

EN54 compliant with approvals pendingE

2 Access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 81: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 79

FP408Conventional fire alarm panel with 8 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Current Consumption (panel only)

Quiescent 137 mA

Alarm 247 mA

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Nominal Voltage 24 VDC

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Expansion Module Slots 4

Ordering Information

Conventional fire alarm panel with 8 zonesFP408 Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404Relay module, 4 supervised relays for NK700/Fx400 fire panelsSB404 Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACTSealed Lead-Acid Battery - 12V 7.2AhBS127N

Modern, attractive designE

Microprocessor controlledE

From 2 up to 16 zonesE

EN54 compliant with approvals pendingE

2 Access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 82: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 80

FP412Conventional fire alarm panel with 12 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Current Consumption (panel only)

Quiescent 137 mA

Alarm 247 mA

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Nominal Voltage 24 VDC

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Expansion Module Slots 4

Ordering Information

Conventional fire alarm panel with 12 zonesFP412

Modern, attractive designE

Microprocessor controlledE

From 2 up to 16 zonesE

EN54 compliant with approvals pendingE

2 Access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 83: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 81

FP416Conventional fire alarm panel with 16 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Current Consumption (panel only)

Quiescent 137 mA

Alarm 247 mA

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Nominal Voltage 24 VDC

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Expansion Module Slots 4

Ordering Information

Conventional fire alarm panel with 16 zonesFP416

Modern, attractive designE

Microprocessor controlledE

From 2 up to 16 zonesE

EN54 compliant with approvals pendingE

2 Access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 84: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 82

RB404Relay module, 4 potential free relays for NK700/Fx400 fire panels

The RB404 relay expander module provides 4 additional voltage freerelays on the GE Security NK700/FP400/FEC400 conventional firepanels ranges. It allows for these relays to be allocated to individualdetection zones, or for programming the activation of different relaysdepending on the status of one or more zones. Up to 4 of thesemodules may be used on every fire panel.

Specifications

Relay rating

Voltage 250 VAC / 30 VDC

Current 10 A

Delay setting 0 to 9 minutes

Ordering Information

Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404

4 Potential free relaysE

Up to 4 modules may be housed inside the fire panelcabinet

E

Programmable with basic boolen functionsE

Power supplied from fire panel busE

Output delay setting per relayE

Page 85: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 83

SB404Relay module, 4 supervised relays for NK700/Fx400 fire panels

The SB404 expander module provides 4 additional supervised relaysthat provide 24 VDC outputs on the GE Security NK700/FP400/FEC400conventional fire panels ranges. These relays may be configured topower sounders or as standard 24 VDC supervised outputs for otherdevices. Relays may be allocated to individual detection zones, or forprogramming the activation of different relays depending on the statusof one or more zones. Up to 4 of these modulesmay be used on every fire panel.

Specifications

Auxiliary supply 24 VDC

Relay Rating

Voltage 250 VAC / 30 VDC

Current 5 A

Delay setting 0 to 9 minutes

Ordering Information

Relay module, 4 supervised relays for NK700/Fx400 fire panelsSB404

4 Supervised relaysE

Up to 4 modules may be housed inside the fire panelcabinet

E

Programmable with basic boolen functionsE

Output delay setting per relayE

Configurable for sounder control or as supervisedoutputs

E

Page 86: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 84

FEC403Conventional extinguishing control panel with 3 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Batteries

Capacity 2 x 7 Ah

Fuse rating 2 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing Relay Outputs

Maximum load 350 mA

Fuse rating 1 A

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum Load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional extinguishing control panel with 3 zonesFEC403

Modern, attractive designE

Microprocessor controlledE

3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE

Automatic extinguishing agent release controlE

2 Access levelsE

Supervised general sounder outputE

Supervised extinguishing inputs and outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 87: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 85

FEC406Conventional extinguishing control panel with 6 zones

The FP400 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The panels come inelegant, high-quality, conveniently sized, heavy-duty metal enclosureswith space for batteries and finished in high-gloss paint. All panelshave a high-quality keyboard with audible metallic click and goodtravel

Specifications

Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Batteries

Capacity 2 x 7 Ah

Fuse rating 2 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay Outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing Relay Outputs

Maximum load 350 mA

Fuse rating 1 A

Auxilliary Output 250 mA

24 VDC Resetable Output

Maximum Load 100 mA

Reset time 3 s

Environment

Working temperature -5°C to +40°C

Relative humidity (noncondencing)

95 %

IP rating IP30

Physical Characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional extinguishing control panel with 6 zonesFEC406

Modern, attractive designE

Microprocessor controlledE

3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE

Automatic extinguishing agent release controlE

2 Access levelsE

Supervised general sounder outputE

Supervised extinguishing inputs and outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 88: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 86

FP6044-zone Conventional Fire Panel

The FP 604 fire panel is designed using the latest technologies and iscompatible with most brands of conventional fire detectors. The FP 604is a 4-zone panel which is extendable up to 6 zones.

Specifications

Supply voltage 230 V (± 10% - 50 Hz ± 5%)

Total current 12 V dc (no charge),quiescent

80 mA

Total current 24 V dc (no charge),quiescent

90 mA

Auxiliary output 100 mA - 12 V dc

Battery back-up for 72 hrs 1 x 12 V - 7.2 Ah battery

Battery charger fuse 2 A

Battery charger voltage 13.8 V

Bells - Fire Brigade fuse 315 mA

Dimensions 390 x 315 x 85 mm

Ordering Information

4-zone Conventional Fire PanelFP604Two zone extension board, including 6 outputsZI602Set of 6 bi-stable magnetic latch relaysRC606 One man maintenanceE

Alarm verificationE

Individual zone alarm outputsE

One 12 V back-up batteryE

12 V dc auxiliary outputE

4 - 6 zonesE

Mixed zone capabilityE

Head removal optionE

Sirens output 12 or 24 V dcE

Microprocessor basedE

EN 54 p2/4 approvedE

LPCB certifiedE

Optional third sourceE

Optional digital diallerE

Page 89: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 87

ZI602Two zone extension board, including 6 outputs

This board extends the FP604 from 4 zones to 6 zones. It also provides6 outputs for the 6 zones.

Ordering Information

Two zone extension board, including 6 outputsZI602

RC606Set of 6 bi-stable magnetic latch relays

A set of 6 relays for the ZI602 zone extension board

Ordering Information

Set of 6 bi-stable magnetic latch relaysRC606

Page 90: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 88

FP708Fire panel equipped with 8 zones

FP700 seriesA set of four conventional fire panels. The FP708 and FP708C are 8zone non-expandable fire panels. The FP740 and FP740C are 8 zoneexpandable to 40 zones. The FP708C and FP740C have an alarmcounter. All panels can use the full range of LON700 output boards.

Specifications

Dimensions (W x H x D) 444 x 340 x110 mm

Weight (no batteries) 5.5 kg

Supply voltage (see engineeringguide)

230 V ac; 1,5 A; 50 Hz

Quiescent current @20devices/zone

210 mA (8 zones)

Batteries for 24 hrs (in housing) 7.2 Ah

Batteries for 72 hrs 17 Ah

Battery charger rating 1.4 A max

Nominal battery charger voltage@ 25°C

27,6 V

Auxiliary output 1 21 - 29,4 V dc; 1.2 A max.

Auxiliary output 2 11.5 - 12.5 V dc; 0.4 A max.

Total 24 V output (no charging) 3,5 A max

Sounder/warning 0,5 A, 19-31 V dc, polarity reversal

Evacuation/Fire brigade 0,5 A, 19-31 V dc, polarity reversal

Fault and Fire protection relayrating

2 A, @ 42 V

RS 232 port 19200 baud, DB9, 1 start, 8 data, 1 stop, no parity

Ordering Information

Fire panel equipped with 8 zonesFP708Fire panel equipped with 8 zones including alarm counterFP708CFire panel equipped with 8 zones expandable up to 40 zonesFP740Fire panel equipped with 8 zones exp. to 40 including alarm counterFP740C

Fully modularE

LON based networkE

One-man maintenanceE

Alarm verificationE

700 series detectors Clean Me® detectionE

Various output boardsE

EN54 approved and BOSEC certifiedE

Modular up to 40 zonesE

Full line of repeatersE

Microprocessor basedE

Local and remote controlE

Page 91: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 89

FR708Repeater 8 zones, 24 VDC input

FR700 seriesThe repeaters provide different solutions - 24 volt input and 230 voltinput using the PS700 power supply. The FR708 is 8 zones nonexpandable and the FR740 is 8 zones expandable to 40 zones. TheFR700 repeaters connect to the FP700 fire panel with the LON 700 bus. The FR708V230 and FR740V230 include a card cage for LON boardexpansion and have a PS700 power supply.

Ordering Information

Repeater 8 zones, 24 VDC inputFR708Repeater 8 zones with card cage and PS700 PSU (230V input)FR708V230Repeater 8 zones, expandable up to 40 zones, 24 VDC inputFR740Repeater 8 zones, exp to 40 zones with card cage and PS700 PSU (230V)FR740V230

Fully modularE

Echelon based networkE

Various output boardsE

Modular up to 40 zonesE

Full line of repeatersE

Microprocessor basedE

Local and remote controlE

Page 92: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 90

ZE7088 zone indicator LED extension board fire/fault

FP700 seriesThis zone indicator extension board is used to expand the FP740 andFR740 front panel indications.

Ordering Information

8 zone indicator LED extension board fire/faultZE708

Page 93: Aritech Master Fire Product Catalogue (06.12.05)

LON700 Devices

Page : 91

ZI7088 zone input extension board

The ZI708 is an eight zone input expansion board for LON700compatible systems. It allows for the connection of up to 8conventional fire detector zones and is compatible with most industrystandard conventional detectors.

Ordering Information

8 zone input extension boardZI708

Page 94: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 92

FM740Synoptic driver for 80 LEDs and common signals

LON 700 seriesA LON700 output board to display LED's. It can be self-standing as wellas plugging into a card cage.

Specifications

Dimensions mm (L x W x D) 150x30x60

Weight 200 g

Operating temp °C -5°C - +40

Operating voltage Vdc 19 - 30

Current consumption

max quiesent mA 30

power consumption per LED(mW)

40

Bus Connection

FP1200/FP2000 (withLON2000)

***

FP700 (direct connection) ***

Bus Cable Cat 5

Total number of repeaters

FP1200/FP2000 15

FP700 8

Ordering Information

Synoptic driver for 80 LEDs and common signalsFM740

Page 95: Aritech Master Fire Product Catalogue (06.12.05)

LON700 Devices

Page : 93

OCB724LON700 output board with 24 open collector outputs

The OCB724 is a 24 way open collector board used in a LON700system.

Ordering Information

LON700 output board with 24 open collector outputsOCB724

RB708LON700 output board with 8 relays

The RB708 is an eight way relay board used in LON700 systems.

Specifications

Number of outputs 8

Relay contact rating

Switching current 2A

Switching volage 42V ac/dc

Switching power 60W

Ordering Information

LON700 output board with 8 relaysRB708

Page 96: Aritech Master Fire Product Catalogue (06.12.05)

LON700 Devices

Page : 94

SOB708LON700 output board with 8 supervised outputs

The SOB708 provides eight supervised outputs that can be used inLON700 systems.

Specifications

Number of outputs 8

Output type polarity reversal

End of line resistor 5.6 Kohm

Output current per output 500mA

Total current for all outputs 2A

Open circuit >27 Kohm

Normal 1.2 - 18 Kohm

Short circuit < 470 ohm

Ordering Information

LON700 output board with 8 supervised outputsSOB708

Page 97: Aritech Master Fire Product Catalogue (06.12.05)

Conventional Fire Systems

Page : 95

FB708FP700 black box with 7 slot card cage

LON700 seriesThe FB708 and FB740 'black boxes' allow for the distribution of LON700input / output units. When used with the NC700 or FM740, the FB7xx isconnected to the FP700 / FP2000 firepanels with the LON700 bus.

Ordering Information

FP700 black box with 7 slot card cageFB708FP700 black box with 11 slot card cage and PS700FB740LON700 interface boardNC700

Fully modularE

Echelon based networkE

Various output boardsE

Microprocessor basedE

Local and remote controlE

For fire panel distributed systemsE

7 slot card cage or 11 slot card cage with power supplyE

Page 98: Aritech Master Fire Product Catalogue (06.12.05)

LON700 Devices

Page : 96

NC700LON700 interface board

The NC700 is an interface board to connect a LON700 bus from a firepanel to a FB7xx 'black box'.

Ordering Information

LON700 interface boardNC700

PS700Plug-in power supply 3.5 A

The PS700 power supply can be used to extend the power output inLON700 systems.

Ordering Information

Plug-in power supply 3.5 APS700

Page 99: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 97

FP1501Analogue addressable fire detection panel - 1 loop

The FP1501 1 loop analogue addressable fire alarm control panel is theideal solution for small to medium-sized installations. Very powerfuland cost-effective, it is extremely simple to install and use due to isergonomic, advanced design. The panel is supplied in an elegant,high-quality, conveniently sized, heavy-duty enclosure. It has ahigh-quality keyboard with audible metallic click and good travel.

Specifications

Supply Voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

Current Consumption 175 mA Quiescent / 241 mA in alarm with no devicesconnected

Batteries

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse Rating 3 A

Charger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)

Loop characteristics per loop

Capacity 250 addresses per loop

Maximum Load 400 mA / 26 VDC to 32 VDC

Maximum ElectricalCharacteristics

44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable

Sounders (reverse polaritysupervision)

Maximum Load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC

Delays 10 seconds to 600 seconds, software adjustable in 10second intervals

Relay Outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary Output

Maximum Load 250 mA @ 18 VDC to 28 VDC

Environment

Working Temperature -5°C to +40 °C

Relative Humidity 0-95% non-condensing

IP Rating IP30

Physical Characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Ordering Information

Analogue addressable fire detection panel - 1 loopFP1501

One and two loop control panelsE

4 x 40 characters LCD displayE

20 Display zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

2 Programmable voltage free relaysE

24 Volt auxiliary outputE

I/O programming capabilities with Boolean functionsE

Day/night sensitivity settingsE

Coincidence within zonesE

Installation test capabilityE

Full networking capabilities up to 10 nodesE

2-wire RS485 communications networkE

Industry standard RS232 communications portE

Easy up/download programming from a standard PCE

Graphic PC softwareE

Page 100: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 98

FP1502Analogue addressable fire detection panel - 2 loops

The FP1500 series analogue addressable fire alarm control panels isthe ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due totheir ergonomic, advanced design.

The panels are supplied in an elegant, high-quality, conveniently sized,heavy-duty metal enclosure and are finished in a high-gloss paint. Allpanels have a high-quality keyboard with audible metallic click andgood travel.

The batteries for the system may be housed inside the cabinet.

Specifications

Supply Voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

Current Consumption 175 mA Quiescent / 241 mA in alarm with no devicesconnected

Batteries

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse Rating 3 A

Charger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)

Loop characteristics per loop

Capacity 250 addresses per loop

Maximum Load 400 mA / 26 VDC to 32 VDC

Maximum ElectricalCharacteristics

44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable

Sounders (reverse polaritysupervision)

Maximum Load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC

Delays 10 seconds to 600 seconds, software adjustable in 10second intervals

Relay Outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary Output

Maximum Load 250 mA @ 18 VDC to 28 VDC

Environment

Working Temperature -5°C to +40 °C

Relative Humidity 0-95% non-condensing

IP Rating IP30

Physical Characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Ordering Information

Analogue addressable fire detection panel - 2 loopsFP1502

One and two loop control panelsE

4 x 40 characters LCD displayE

20 Display zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

2 Programmable voltage free relaysE

24 Volt auxiliary outputE

I/O programming capabilities with Boolean functionsE

Day/night sensitivity settingsE

Coincidence within zonesE

Installation test capabilityE

Full networking capabilities up to 10 nodesE

2-wire RS485 communications networkE

Industry standard RS232 communications portE

Easy up/download programming from a standard PCE

Graphic PC softwareE

Page 101: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 99

NC785RS485 expansion kit for KSA701/FP1500 fire panels

The NC785 RS485 expander allows for an easy upgrade to theKSA701/FP1500 series addressable fire panels. Each module adds anadditional industry standard RS485 communication port to the panel.This port could be used for communications with other network nodesin the fire panel network.

Specifications

Number of ports 1

Communications medium RS485

Technical specifications

Maximum cable length 1200 m

Communication speed 9600 baud

Cable CAT5 - twisted with screen

Termination resistance 150 Ohm

Ordering Information

RS485 expansion kit for KSA701/FP1500 fire panelsNC785

Industry standard RS485 communicationsE

No hardware configuration requiredE

Page 102: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 100

FR1500Analogue addressable LCD Repeater/Emulator (AC Powered)

The FP1500 Series analogue addressable fire alarm panels are theideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are easy to install and use due to theirergonomic, advanced design. The FR1500 LCD repeater is supplied inthe same enclosure as the FP1500.

Specifications

Supply Voltage

AC Version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

DC Version 24 VDC

Current Consumption 175 mA Quiescent / 200 mA in alarm

Battery Charger (AC Version only)

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse Rating 3 A

Charger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)

Environment

Working Temperature -5°C to +40 °C

Relative Humidity 0-95% non-condensing

IP Rating IP30

Physical Characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Communication Ports RS232 and RS485 standard

Ordering Information

Analogue addressable LCD Repeater/Emulator (AC Powered)FR1500

Modern, attractive designE

4 x 40 characters LCD displayE

20 Display zonesE

EN54 compliant with approvals pendingE

3 User access levelsE

24 VDC or 230 VAC models availableE

Panel networkingE

Full system controlE

Page 103: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 101

MODGSMGSM Modem for KSA700/FP1500 Series Fire Panels

The MODGSM modem may be used in KSA701/FP1500, KSA702 andKSA705 fire panel from GE-Interlogix. It is ideal for use as a standardmodem for making and receiving calls from and to the fire panel, butmay also be used for GSM messaging.

Specifications

GSM Band 900/1800 MHz

Services Data, SMS, Voice and Fax

AT Commands GSM 07.07 and 07.05

Output Power (max)

GSM900 2 W

GSM1800 1 W

Input Voltage 5 to 32 V

Current @ 5V

Avarage 330 mA

Peak 1.8 A

SIM Interface 3V / 5V

Dimensions (h x w x d) 98 x 54 x 25 mm

Weight 130 g

Environmental Temperature

Storage - 25 °C to + 70 °C

Operating - 20 °C to + 55 °C

Ordering Information

GSM Modem for KSA700/FP1500 Series Fire PanelsMODGSM

Dual-Band 900/1800 MHzE

Data and SMS servicesE

Remote control by AT commandsE

Wide input voltage rangeE

Page 104: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 102

PCG-Graphic102Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)

The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-Config102 operates with a single panel and allowsfor the configuration of all devices up to a maximum of two loops.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display SVGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 1 GHz or higher Pentium III-compatible CPU

RAM 256 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Windows '98 or Windows 2000

Ordering Information

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)PCG-Graphic102

Bi-directional communication with single panels andnetworked fire systems

E

Local or remote connection via modem or TCP/IPE

Large selection of user configurable iconsE

Visualises device alarms and status of in- and outputsE

Event texts retrieval from the panelE

Configurator and operator contol levelsE

Navigation buttons allowedE

Event logs with reporting facilitiesE

Basic drawing package includedE

Imports bmp & drw format graphicsE

Page 105: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 103

PCG-GraphicNWGraphic Software for KSA700/FP1500 Fire Systems (multi-panel)

The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-ConfigNW allows for monitoring on networkedsystems with multiple panels.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display SVGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 1 GHz or higher Pentium III-compatible CPU

RAM 256 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Windows '98 or Windows 2000

Ordering Information

Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)PCG-GraphicNW

Bi-directional communication with single panels andnetworked fire systems

E

Local or remote connection via modem or TCP/IPE

Large selection of user configurable iconsE

Visualises device alarms and status of in- and outputsE

Event texts retrieval from the panelE

Configurator and operator contol levelsE

Navigation buttons allowedE

Event logs with reporting facilitiesE

Basic drawing package includedE

Imports bmp & drw format graphicsE

Page 106: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 104

FP1216ENAnalogue addressable fire panel 2 - 4 loops, 16 zones

The FP1216EN is a versatile, cost effective analogue addressable firepanel with 2 to 4 loops and powerfull I/O features. It supports all theLON700 devices and repeaters, and can be optionally upgraded toprovide full networking. The FP1216EN is truly user friendly andprovides a generous 8 x 40 graphic, backlit display. I/O control is donevia the powerful FP2000/FP1200 series boolean I/O programingmodule. Extensive maintenance features are provided standard. TheFP1216EN supports both 2000 and 900 series sensors and I/O units.

Specifications

Supply voltage 230 V ac (+10/-15%)

50 Hz220 VA

Min. supply current @ 24 VDC 0.2 A

Battery charger rating @ 27.6VDC

1.6 A

Total supply rating @ 27.6 VDC 4 A

Relay rating @ 24 VDC 2 A

Weight (no batteries) 7.5 kg

Dimensions (h x w x d) 440 x 444 x 125 mm

Ordering Information

Analogue addressable fire panel 2 - 4 loops, 16 zonesFP1216EN LCD repeater with emulator functionsFR2000 Rim surround for the 780 and 1200N series fire panel boxesFP-RIM12702-loop extension board for FP1200 / FP2000 fire panelsLC2002LON700 driver for FP1200 / FP2000LON2000Modem kitMOD2000ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051RS485 network extension boardNE2011Fibre optic network extension boardNE2051 Graphics package network application with copy protection keyPCG-NGraphics package with copy protection keyPCG-SProgramming and configuration softwarePCC2000Maintenance and support software with copy protection keyPCM2000

One man maintenanceE

Soak testE

On-line diagnostics and statisticsE

Power supply for 72 hour autonomyE

Floating background for 2000 series sensorsE

Coincidence within and in between zonesE

Start-up default modeE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

EN 54 p2 & 4 approvedE

Bosec certifiedE

2 or 4 class A loopsE

Full range of LON700 devicesE

Page 107: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 105

FP2416Analogue addressable fire panel 2 - 4 loops, 16 zones

FP2000 SeriesA versatile, powerful analogue addressable fire panel, 2 to 4 loops, 16displayed zones with extensive I/O features. The fire panel can operatewithin a 31 panel network and can communicate with global repeatersand PC grahics. It also supports all the LON700 devices and repeatersusing a seperate two wire bus. The FP2000 series is truly user-friendly,and provides a generous 8 x 40 backlit graphic display. I/O control isdone via the powerful FP2000/FP1200 series boolean I/O programingmodule. Extensive maintenance features are provided standard. TheFP2000 series supports both 2000 and 900 series sensors and I/O units.

Specifications

Supply voltage 1 190 - 270 V ac

40- 60 Hz160 VA max.

Supply voltage 2 21 - 27 V dc

Current consumption

Quiescent @ 24 V dc (equippedloop)

500 mA

Alarm current @ 24 V dc 600 mA

Available auxiliary current inalarm

3.4 A

Battery charger rating @ 27.5 Vdc

3 A

Total supply rating @ 27.5 V dc 4 A

Relay rating @ 24 V dc 2 A

Weight (no batteries) 11 kg

Dimensions (mm) (H x W x D) 609 x 441 x 109

Ordering Information

Analogue addressable fire panel 2 - 4 loops, 16 zonesFP2416LCD repeater with emulator functionsFR20002-loop extension board for FP1200 / FP2000 fire panelsLC2002ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051RS485 network extension boardNE2011Fibre optic network extension boardNE2051LON700 driver for FP1200 / FP2000LON20002 wire repeatersLON700LCD repeaterFRL700Modem kitMOD2000Maintenance and support software with copy protection keyPCM2000Programming and configuration softwarePCC2000PC Graphic Software Packages for Aritech Fire SytemsPCG SeriesInternal printerPR2000

One man maintenanceE

Graphic maintenanceE

Maintenance warningE

Service reminder signalE

Soak testE

On-line diagnostics and statisticsE

Floating backgroundE

Day/night sensitivity settingE

Coincidence within and in between zonesE

Automatic timed and manual on/off zonesE

Start-up default modeE

Service switchE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

EN54 approved, certified Bosec, VdS, NFA2PE

Networkable "black box" and "global zone" systemE

Full range of repeater panelsE

Full range of LON700 devicesE

Page 108: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 106

FP2432Analogue addressable fire panel 2 - 4 loops, 16 - 32 zones

FP2000 SeriesA versatile, powerful analogue addressable fire panel, 2 to 4 loops, 16to 32 displayed zones with extensive I/O features. The fire panel canoperate within a 31 panel network and can communicate with globalrepeaters and PC grahics. It also supports all the LON700 devices andrepeaters using a seperate two wire bus. The FP2000 series is trulyuser-friendly, and provides a generous 8 x 40 backlit graphic display. I/O control is done via the powerful FP2000/FP1200 series boolean I/Oprograming module. Extensive maintenance features are providedstandard. The FP2000 series supports both 2000 and 900 seriessensors and I/O units.

Specifications

Supply voltage 1 190 - 270 V ac

40- 60 Hz160 VA max.

Supply voltage 2 21 - 27 V dc

Current consumption

Quiescent @ 24 V dc (equippedloop)

500 mA

Alarm current @ 24 V dc 600 mA

Available auxiliary current inalarm

3.4 A

Battery charger rating @ 27.5 Vdc

3 A

Total supply rating @ 27.5 V dc 4 A

Relay rating @ 24 V dc 2 A

Weight (no batteries) 11 kg

Dimensions (mm H x W x D) 609 x 441 x 109

Ordering Information

Analogue addressable fire panel 2 - 4 loops, 16 - 32 zonesFP2432LCD repeater with emulator functionsFR20002-loop extension board for FP1200 / FP2000 fire panelsLC200216-zone LED extension fire and fault LEDZE2016ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051RS485 network extension boardNE2011Fibre optic network extension boardNE2051LON700 driver for FP1200 / FP2000LON20002 wire repeatersLON700LCD repeaterFRL700Modem kitMOD2000Maintenance and support software with copy protection keyPCM2000Programming and configuration softwarePCC2000PC Graphic Software Packages for Aritech Fire SytemsPCG Series

One man maintenanceE

Graphic maintenanceE

Maintenance warningE

Service reminder signalE

Soak testE

On-line diagnostics and statisticsE

Floating backgroundE

Day/night sensitivity settingE

Coincidence within and in between zonesE

Automatic timed and manual on/off zonesE

Start-up default modeE

Service switchE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

EN54 approved, certified Bosec, VdS, NFA2PE

Networkable "black box" and "global zone" systemE

Full range of repeater panelsE

Full range of LON700 devicesE

Page 109: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 107

FP2864Analogue addressable fire panel, 2 - 8 loops, 16 - 64 zones

The FP2864 is a versatile, powerful analogue addressable fire panel, 2to 8 loops, 16 to 64 displayed zones with extensive I/O features. It canoperate within a 31 panel network and can communicate with globalrepeaters and PC grahics. It also supports all the LON700 devices andrepeaters using a seperate two wire bus.The panel is trulyuser-friendly, and provides a generous 8 x 40 backlit graphic display.I/O control is done via the powerful 2000/1200 series boolean I/Oprograming module. Extensive maintenance features are providedstandard. The FP2864 supports 2000, 1500 and 900 series sensors andI/O units.

Specifications

Supply voltage 1 190 - 270 VAC

40 - 60 Hz160 VA max.

Supply voltage 2 21 - 27 VDC

Current consumption

Quiescent @ 24 VDC(equipped loop)

800 mA

Alarm current @ 24 VDC 1 A

Available auxiliary current inalarm

3 A

Battery charger rating @ 27.5VDC

3 A

Total supply rating @ 27.5 VDC 4 A

Relay rating @ 24 VDC 2 A

Weight (no batteries) 15 kg

Dimensions (H x W x D) 804 x 441 x 109 mm

Ordering Information

Analogue addressable fire panel, 2 - 8 loops, 16 - 64 zonesFP2864 2000 Series bus termination boardBUS2000ESPA protocol hardware keyESPA20002-loop extension board for 1200/2000 series fire panelsLC1502LON700 driver for FP1200 / FP2000LON2000LON driver for FP1200/2000 - closed loop systemsLON2000RModem kitMOD2000ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051RS485 network extension boardNE2011Fibre optic network extension boardNE2051Internal printerPR2000Relay extension board for 1200/2000 series fire panelsRB20162000 Series Memory Expansion KitRE200416-zone LED extension fire and fault LEDZE2016 Maintenance and support software with copy protection keyPCM2000Programming and configuration softwarePCC2000 Graphics package network application with copy protection keyPCG-NGraphics package with copy protection keyPCG-S

One man maintenanceE

Graphic maintenanceE

Maintenance warningE

Service reminder signalE

Soak testE

On-line diagnostics and statisticsE

Floating backgroundE

Day/night sensitivity settingE

Coincidence within and in between zonesE

Automatic timed and manual on/off zonesE

Start-up default modeE

Service switchE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

EN54 approved, certified Bosec, VdS, NFA2PE

Networkable "black box" and "global zone" systemE

Full range of repeater panelsE

Full range of LON700 devicesE

Page 110: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 108

FB2400Analogue addressable fire panel 2 - 4 loops, 'black box'

FP2000 seriesThe FB2400 / FB2800 'black box' system allows a cost-effectivenetwork of fire panels to be interconnected to a global repeater usingthe FP2000 series arcnet network. The FB black boxes have all thefeatures of the FP2000 series of fire panels, but have no display /keyboard. All controls and display is done via the global repeater.

Specifications

Supply voltage 1 190 - 270 V ac

40- 60 Hz160 VA max.

Supply voltage 2 21 - 27 V dc

Current consumption

Quiescent @ 24 V dc (equippedloop)

500 mA

Alarm current @ 24 V dc 600 mA

Available auxiliary current inalarm

3.4 A

Battery charger rating @ 27.5 Vdc

3 A

Total supply rating @ 27.5 V dc 4 A

Relay rating @ 24 V dc 2 A

Weight (no batteries) 11 kg

Dimensions (mm) (H x W x D) 609 x 441 x 109

Ordering Information

Analogue addressable fire panel 2 - 4 loops, 'black box'FB2400Analogue addressable fire panel 2 - 8 loops, 'black box'FB2800

One man maintenanceE

Graphic maintenanceE

Maintenance warningE

Service reminder signalE

Soak testE

On-line diagnostics and statisticsE

Floating backgroundE

Day/night sensitivity settingE

Coincidence within and in between zonesE

Automatic timed and manual on/off zonesE

Start-up default modeE

Service switchE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

Networkable "black box" and "global zone" systemE

Full range of repeater panelsE

Page 111: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 109

LC20022-loop extension board for FP1200 / FP2000 fire panels

FP1200 / FP2000 series

Specifications

Current consumption

Quiescent @ 24 V dc (Fullyequipped loop)

+ 150 mA (252 detectors)

Ordering Information

2-loop extension board for FP1200 / FP2000 fire panelsLC2002

ZE201616-zone LED extension fire and fault LED

The ZE2016 allows the extension of the zones of the Fx2x32 andFx2x64 fire panels and repeaters by 16 additional zones.

Ordering Information

16-zone LED extension fire and fault LEDZE2016

Page 112: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 110

LON2000LON700 driver for FP1200 / FP2000

FP1200 / FP2000 seriesA LON700 driver that connects FP1200 / FP2000 fire panels to LON700devices

Ordering Information

LON700 driver for FP1200 / FP2000LON2000

NC2011ARCNET RS485 network card with single RS485 interface

The NC2011 is an interface board to connect an RS485 copper networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2011 pre installed.

Ordering Information

ARCNET RS485 network card with single RS485 interfaceNC2011RS485 network extension boardNE2011

Page 113: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 111

NC2051ARCNET network card with single optical interface board

The NC2051 is an interface board to connect a fiber optic networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2051 pre installed.

Ordering Information

ARCNET network card with single optical interface boardNC2051Fibre optic network extension boardNE2051

NE2011RS485 network extension board

The NE2011 is a RS485 network extension board for the NC2011 toallow dual bus and closed ring networks.

Ordering Information

RS485 network extension boardNE2011

Page 114: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 112

NE2051Fibre optic network extension board

FP1200 / FP2000 seriesAn extension board for the NC2051 to allow a fibre optic ring bus

Ordering Information

Fibre optic network extension boardNE2051

Page 115: Aritech Master Fire Product Catalogue (06.12.05)

LON700 Devices

Page : 113

FRL700LCD repeater

The LON700 LCD repeater is a smart and compact, cost-effectivesolution for fire panel repeaters. It is also available as an FBP700 firebrigade panel for Dutch and Scandinavian norms.

Specifications

Dimensions (l x w x d) 240 x 320 x 60 mm

Weight 1.5 kg

Operating temp °C -5°C to +40°C

Operating voltage 15 - 30 VDC

Current consumption

Max. quiesent 100 mA

Bus Connection two wire LON700

Bus Cable CAT 5

Total number of repeaters

700/1200/2000 Series 15

Ordering Information

LCD repeaterFRL700

2 wire connection between fire panel and repeatersE

Up to 1500 metre bus lengthE

24 Volt power supplyE

Cost effective repeater solutionsE

Easily installed, simple operationE

4 x 20 charater LCD display, common LED's, pushbutton control

E

LON700 moduleE

Page 116: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 114

FR2000LCD repeater with emulator functions

FP1200 / FP2000 seriesA powerful LCD repeater that can be used as a local or global repeateron a FP1200 / FP2000 fire panel network. Fire panels can be emulatedfrom the FR2000. An 80 x 40 backlit graphic display and full indicationand control keyboard is provided standard.

Specifications

Supply voltage 230 V ac (+10/-15%)

50 Hz50 VA

Min. supply current @ 24 V dc 0.15 A

Battery charger rating @ 27.6 Vdc

0.3 A

Total supply rating @ 27.6 V dc 1 A

Relay rating @ 24 V dc 2 A

Weight (no batteries) 7.5 kg

Dimensions (mm H x W x D) 365 x 444 x 111

Ordering Information

LCD repeater with emulator functionsFR2000RS485 network extension boardNE2011Fibre optic network extension boardNE2051Rim surround for the 780 and 1200N series fire panel boxesFP-RIM1270

8 x 40 character graphic displayE

Arcnet network connection to FP1200/FP2000 seriesfirepanels

E

Global repeater functionE

Comprehensive control and display functionsE

Fire panel emulation functionE

Dual RS232 portsE

Page 117: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 115

FR2032Repeater / emulator 16 - 32 zones or panels

FP1200 / FP2000 seriesA repeater / emulator with 16, expandable to 32, displayed fire andfault zones, used in FP1200 / FP2000 networked systems. The repeateris connected on the arcnet network and can operate in a local orglobal repeater mode. An 80 x 40 backlit graphic display and fullindication and control keyboard is provided standard.

Specifications

Supply voltage 21 - 28 V dc

Current consumption 300 mA max

Weight 11 kg

Dimensions (mm H x W x D) 609 x 441 x 109

Ordering Information

Repeater / emulator 16 - 32 zones or panelsFR2032RS485 network extension boardNE2011Fibre optic network extension boardNE205116-zone LED extension fire and fault LEDZE2016

8 x 40 character graphic displayE

Arcnet network connection to FP1200 / FP2000 seriesfirepanels

E

Global repeater functionE

Comprehensive control and display functionsE

16 zones fire and fault expandable to 32 zonesE

24 Volt operationE

Emulation functionsE

Page 118: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 116

FR2064Repeater/emulator 16 - 64 zones or panels

A repeater/emulator with 16 fire and fault zones, expandable to 64,used in 1200/2000 series networked systems. The repeater isconnected on the arcnet network and can operate in a local or globalrepeater mode. An 80 x 40 character, backlit graphic display and fullindication and control keyboard is provided standard.

Specifications

Supply voltage 1

160 VA max.Supply voltage 2 21 - 27 VDC

Current consumption

Quiescent @ 24 VDC(equipped loop)

300 mA

Alarm current @ 24 VDC

Available auxiliary current inalarm

Battery charger rating @ 27.5VDC

Total supply rating @ 27.5 VDC

Relay rating @ 24 VDC

Weight (no batteries) 15 kg

Dimensions (H x W x D) 804 x 441 x 109 mm

Ordering Information

Repeater/emulator 16 - 64 zones or panelsFR2064 2000 Series bus termination boardBUS2000ESPA protocol hardware keyESPA2000LON700 driver for FP1200 / FP2000LON2000LON driver for FP1200/2000 - closed loop systemsLON2000RModem kitMOD2000RS485 network extension boardNE2011Fibre optic network extension boardNE2051Internal printerPR200016-zone LED extension fire and fault LEDZE2016

8 x 40 character graphic displayE

Arcnet network connection to FP1200 / FP2000 seriesfirepanels

E

Global repeater functionE

Comprehensive control and display functionsE

Emulation functionE

16 to 64 zones fire and fault displayedE

24 volt operationE

Page 119: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 117

UN2011FP1200 / FP2000 arcnet to RS232 converter

FP1200 / FP2000 seriesThe unversal node allows the fire panel arcnet network to be extendedto computer software applications either locally with the RS232interface, or remotely using the MOD2000. It has a 230 volt powersupply and battery charger self contained in the unit.

Specifications

Input voltage 230 V ac, 50 Hz, 10 VA

Battery type 12 V 1,2 Ah

Fault relay 2 A @ 24 V dc, 50 W dc

Weight 5 kg

Dimensions mm (H x W x D) 400 x 300 x 65

Operating remperature 0 - 40 °C

Ordering Information

FP1200 / FP2000 arcnet to RS232 converterUN2011Modem kitMOD2000

FP1200 / FP2000 arcnet to RS232 interfaceE

Allows computer applications to operate on the firepanel network

E

230V operation and battery chargerE

Can be extended with MOD2000 for remote operationE

'Black box' operationE

Page 120: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 118

MOD2000Modem kit

FP1200 / FP2000 seriesAn internal modem for the FP1200 / FP2000 fire panels or a UN2011universal node. The modem has the autonomy of the fire panel powersupply, and has extended telephone line protectection. The MOD2000can also be used with a computer.

Ordering Information

Modem kitMOD2000

MOD2000E

For fire panel and universal node operationE

Internal installationE

Autonomous power supplyE

Page 121: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 119

PCC2000Programming and configuration software

PCC2000 allows easy, menu driven, programming of all the panel'sfeatures and settings. Common texts can be easily copied whilesensors, zones and areas increment or follow automatically. Booleanlogic programming becomes simple as inputs and outputs arecontinuously displayed for the programmer's convenience.

Specifications

Processor 486 66 MHz

RAM 12 Mb

Display adapter VGA

Hard disk space 20 MB

Pointing device MS Mouse

Graphical environment Windows 98, 2000, XP

Communications ports 1 x RS232

1 x Parallel

Ordering Information

Programming and configuration softwarePCC2000

Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem

E

Windows 98, 2000 and XP compatibleE

For use with 2000/1200 series panelsE

Menu drivenE

Full or partial up- and downloadE

Page 122: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 120

PCM2000Maintenance and support software with copy protection key

PCM2000 allows local and remote maintenance facilities for 1200/2000series fire panels. Amongst others, it allows for full panel emulation,data retrieval and central alarm monitoring.

Specifications

Processor Pentium 133Mhz (or better)

RAM 32 Mb (or more)

Display Adapter VGA

Hard Disk Space 20 MB

Pointing Device Bus or P/S2 Mouse

Graphical Environment Windows 98, NT or 2000

Communications ports Depending on Drivers Printer port (for key)

1 Parallel

Ordering Information

Maintenance and support software with copy protection keyPCM2000

Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem

E

Windows 95, 98 and NT compatibleE

For use with FP2000, FP1200E

Full panel emulationE

Data retrievalE

Central stationE

History logE

Address bookE

Dynamic Link Library (DLL) for third party integrationE

Page 123: Aritech Master Fire Product Catalogue (06.12.05)

Addressable Fire Systems

Page : 121

PCG-SGraphics package with copy protection key

2 Packages allow the graphic package to grow with the installation.The basic version PCG-S operates with a single panel, while the PCG-Nsupports a network. Upgrades do not require rework on the existingdatabase, drawings, etc.

Specifications

Item Recommended

Processor Pentium II 266 MHz (or better)

RAM 64 Mb (or more)

Display adapter SVGA or better

Hard disk space 200 MB

Pointing device MS Mouse, Bus or P/S2

Graphical environment Windows NT

Communication ports 1 x RS-232 - Depending on drivers

1 x Parallel - Printer port (for key)

Ordering Information

Graphics package with copy protection keyPCG-S

Provide bi-directional communication with single firepanels and networked fire systems, both locally andremote via modem

E

Windows 2000 and NT compatibleE

For use with FP2000, FP1200, FP1100 and FP700E

Constructed around Sybase SQL AnywhereE

Large selection of iconsE

Visualises inputs & outputsE

Information page per pointE

Get texts from panelE

Several operator levels and passwordsE

Operator configurableE

Multiple navigation buttonsE

Event logsE

Basic drawing package includedE

Imports .bmp & .wmf drawings from virtually anypackage

E

Hardware key protectedE

Page 124: Aritech Master Fire Product Catalogue (06.12.05)

Content

DI322I Ionisation detector, conventional Page : 3

DP331I Optical detector, conventional, with field exchangeable optical block Page : 4

DT313I Temperature detector (fixed and rate-of-rise), conventional Page : 5

KCT731 Calibration Tool for KL731/DP331I Fire Detectors Page : 6

KZ700 Universal fire detector base Page : 7

KZ705 Universal fire detector base with earth connection Page : 8

KZ705D Conventional fire detector base with diode Page : 9

EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels Page : 9

KZ705R Conventional 12 VDC fire detector base with relay Page : 10

S700 Surface mount accessory for KZ700 and KZ705 series bases Page : 11

DP721I Photoelectric smoke detector with remote alarm LED output Page : 12

DP721T Photoelectric smoke and heat detector head with remote alarm LED Page : 13

DT713-5 57º C fixed and rate-of-rise heat detector Page : 14

DT713-7 70º C fixed and R.O.R. heat detector Page : 15

DB702 10 cm diameter base - 6 terminals Page : 16

DI650 Ionisation smoke detector Page : 17

DP652 Optical smoke detector Page : 18

DT654 Heat detector, R.O.R., 57º C A1R Page : 19

DB860 Standard Base Page : 20

DB861 Backplate for Ingress Protection 860-950 Page : 20

DB806 Conduit box for 860 / 950 series bases Page : 21

DB650 650 series relay base Page : 21

DI1552 Ionisation Sensor Page : 22

DP1561 Optical sensor with field exchangeable optical block Page : 23

DP1551T Dual Sensor (Optical/Heat) Page : 24

DT1553 Heat Sensor Page : 25

PG700 Fire sensor programmer Page : 26

KZ705I Analogue fire detector base with isolator Page : 27

KZ705AS Analogue fire detector base with sounder Page : 28

KZ705IAS Analogue fire detector base with isolator and sounder Page : 29

KAL410 Conventional Zone Monitor Unit - 1 Zone Page : 30

KAL414C Conventional Zone Monitor Unit - 4 Zones Page : 31

KAL426C Extinguishing Control Module Page : 32

KAL430 Relay Module - 1 Relay Page : 33

KAL434C Addressable Relay Module - 4 Relays Page : 34

KAL440 Supervised Relay Module Page : 35

KAL450 Addressable Manual Call Point Page : 36

KAL460 Digital Input Module Page : 37

KAL470 Isolator Module Page : 38

KAL490 Retention Module - 1 Input / 1 Output Page : 39

DP2051 Optical Sensor Page : 40

DP2061 Optical Sensor with remote LED output Page : 41

DP2061T Optical and heat multi-sensor with remote LED output Page : 42

DP2071 Optical Sensor with 7-segment display Page : 43

Page 125: Aritech Master Fire Product Catalogue (06.12.05)

DT2053 2000 Series heat sensor Page : 44

DT2063 2000 series heat sensor with remote LED output Page : 45

DT2073 Heat Sensor with 7-segment Display and Remote LED Output Page : 46

DB2001 2000 series base, 2 terminals Page : 47

DB2002 2000 series base, 4 terminals Page : 48

DB2016 Isolating base Page : 49

IU2016 Loop Isolator Page : 50

DB2003 Base for the IU2016 isolator Page : 51

DM2000 Manual call point, flying leads Page : 52

DM2000E Manual call point - Red IP67 waterproof, including backbox Page : 53

IO2014 Input Output unit - 4 inputs Page : 54

IU2050 Single Input Module Page : 55

IU2055 Conventional Zone Monitor Page : 56

GBX2000 Galvanic barrier Page : 57

IU2080 Indicating Circuit Controller Page : 57

FD2705R 2000 series addressable reflective beam detector 5 - 50m Page : 58

AS2015 2000 series loop powered sounder Page : 59

DI950 Analogue addressable ionisation sensor Page : 60

DP951 Optical sensor Page : 60

DT952 Analogue addressable temperature sensor Page : 61

DM960 950 series analogue addressable manual callpoint Page : 61

DI970 Intrinsic safe analogue addressable ionisation detector Page : 62

DP971 Intrisic safe optical detector Page : 62

DT972 Intrinsic safe heat detector Page : 63

DM970 Intrinsic safe manual call point Page : 63

PT971 Intrinsic safe protocol translator Page : 64

GBX70 Galvanic barrier (single channel) Page : 64

II950 950 series mini switch monitor unit Page : 65

II952 950 series switch monitor unit - surface mount Page : 65

II955 950 series zone monitor unit - surface mount Page : 66

IO950 950 series single channel IO - surface mount Page : 66

IO955 950 series output unit - surface mount Page : 67

IO956 950 series sounder circuit controller - surface mount Page : 67

IU950 950 series loop isolator Page : 68

AS950 950 series loop powered sounder Page : 69

AS955 950 series high output loop powered sounder Page : 70

FD950 950 series loop-powered beam detector Page : 71

DB950 950 series standard base Page : 72

DB951 Base for IU 950 Page : 72

DB961 Isolating base (20 devices) Page : 73

DB970 Detector base for 970 series intrinsic safe sensors Page : 73

IU980 Coded cards, addresses 1 - 18 Page : 74

FP202 Conventional fire alarm panel with 2 zones Page : 75

FP204 Conventional fire alarm panel with 4 zones Page : 76

Page 126: Aritech Master Fire Product Catalogue (06.12.05)

FP206 Conventional fire alarm panel with 6 zones Page : 77

FP402 Conventional fire alarm panel with 2 zones Page : 78

FP408 Conventional fire alarm panel with 8 zones Page : 79

FP412 Conventional fire alarm panel with 12 zones Page : 80

FP416 Conventional fire alarm panel with 16 zones Page : 81

RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels Page : 82

SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels Page : 83

FEC403 Conventional extinguishing control panel with 3 zones Page : 84

FEC406 Conventional extinguishing control panel with 6 zones Page : 85

FP604 4-zone Conventional Fire Panel Page : 86

ZI602 Two zone extension board, including 6 outputs Page : 87

RC606 Set of 6 bi-stable magnetic latch relays Page : 87

FP708 Fire panel equipped with 8 zones Page : 88

FR708 Repeater 8 zones, 24 VDC input Page : 89

ZE708 8 zone indicator LED extension board fire/fault Page : 90

ZI708 8 zone input extension board Page : 91

FM740 Synoptic driver for 80 LEDs and common signals Page : 92

OCB724 LON700 output board with 24 open collector outputs Page : 93

RB708 LON700 output board with 8 relays Page : 93

SOB708 LON700 output board with 8 supervised outputs Page : 94

FB708 FP700 black box with 7 slot card cage Page : 95

NC700 LON700 interface board Page : 96

PS700 Plug-in power supply 3.5 A Page : 96

FP1501 Analogue addressable fire detection panel - 1 loop Page : 97

FP1502 Analogue addressable fire detection panel - 2 loops Page : 98

NC785 RS485 expansion kit for KSA701/FP1500 fire panels Page : 99

FR1500 Analogue addressable LCD Repeater/Emulator (AC Powered) Page : 100

MODGSM GSM Modem for KSA700/FP1500 Series Fire Panels Page : 101

PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) Page : 102

PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) Page : 103

FP1216EN Analogue addressable fire panel 2 - 4 loops, 16 zones Page : 104

FP2416 Analogue addressable fire panel 2 - 4 loops, 16 zones Page : 105

FP2432 Analogue addressable fire panel 2 - 4 loops, 16 - 32 zones Page : 106

FP2864 Analogue addressable fire panel, 2 - 8 loops, 16 - 64 zones Page : 107

FB2400 Analogue addressable fire panel 2 - 4 loops, 'black box' Page : 108

LC2002 2-loop extension board for FP1200 / FP2000 fire panels Page : 109

ZE2016 16-zone LED extension fire and fault LED Page : 109

LON2000 LON700 driver for FP1200 / FP2000 Page : 110

NC2011 ARCNET RS485 network card with single RS485 interface Page : 110

NC2051 ARCNET network card with single optical interface board Page : 111

NE2011 RS485 network extension board Page : 111

NE2051 Fibre optic network extension board Page : 112

FRL700 LCD repeater Page : 113

FR2000 LCD repeater with emulator functions Page : 114

Page 127: Aritech Master Fire Product Catalogue (06.12.05)

FR2032 Repeater / emulator 16 - 32 zones or panels Page : 115

FR2064 Repeater/emulator 16 - 64 zones or panels Page : 116

UN2011 FP1200 / FP2000 arcnet to RS232 converter Page : 117

MOD2000 Modem kit Page : 118

PCC2000 Programming and configuration software Page : 119

PCM2000 Maintenance and support software with copy protection key Page : 120

PCG-S Graphics package with copy protection key Page : 121

Page 128: Aritech Master Fire Product Catalogue (06.12.05)
Page 129: Aritech Master Fire Product Catalogue (06.12.05)

www.gesecurity.netAs a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest productspecifications, visit GE Security online or contact your GE Security sales representative.

IPSCAT-2005-12-6 15:44:32