Configuring SaNTa Fe Servers with SmartStart 6.x SaNTa Fe 2.000 Purpose This SOP is used to set up RAID arrays and perform initial server configuration for SaNTa Fe 2.000 servers using Compaq\HP hardware. This SOP is specific to servers that must use Smart Start 6.10 or later. Generally these are servers with the distinction of G2, G3 etc (For Example DL380G3.) SmartStart 6.10 or later will not work on server models older than a G2 model name (For Example DL380.) Procedure Step 1. Assemble the required materials and equipment. The target server (must be one of the Compaq models cited in Volume 10 - Release Notes of the SaNTa Fe Reference Guide 2.000. For a standard SaNTa Fe setup, the server must have at least two 18.2 GB hard drives (on the same controller). It may also have at least three other hard drives (which must be together, either on the same controller as the 18.2 GB drives or on another controller). HP SmartStart version 6.1 CD-ROM Completed Server Information Worksheet Step 2. If the machine has been previously configured with SmartStart, remove any existing system configuration or data. If the machine has not been previously configured, go to Step 3. a) If the server has an external drive cabinet, turn it on; then power up the server and insert the SmartStart CD into the server’s CD drive. The system boots and loads SmartStart; Input the SmartStart Language and Keyboard (English, English) Standard Operating Procedure Page 1 of 18 – Effective Date February 1 st 2003

Upload: yasin99999

Post on 02-Apr-2015

310 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Array Configuration

Configuring SaNTa Fe Servers with SmartStart 6.xSaNTa Fe 2.000

Purpose

This SOP is used to set up RAID arrays and perform initial server configuration for SaNTa Fe 2.000 servers using Compaq\HP hardware. This SOP is specific to servers that must use Smart Start 6.10 or later. Generally these are servers with the distinction of G2, G3 etc (For Example DL380G3.) SmartStart 6.10 or later will not work on server models older than a G2 model name (For Example DL380.)

Procedure

Step 1. Assemble the required materials and equipment.

The target server (must be one of the Compaq models cited in Volume 10 - Release Notes of the SaNTa Fe Reference Guide 2.000.

For a standard SaNTa Fe setup, the server must have at least two 18.2 GB hard drives (on the same controller). It may also have at least three other hard drives (which must be together, either on the same controller as the 18.2 GB drives or on another controller).

HP SmartStart version 6.1 CD-ROM

Completed Server Information Worksheet

Step 2. If the machine has been previously configured with SmartStart, remove any existing system configuration or data.

Note: If the machine has not been previously configured, go to Step 3.

a) If the server has an external drive cabinet, turn it on; then power up the server and insert the SmartStart CD into the server’s CD drive. The system boots and loads SmartStart; Input the SmartStart Language and Keyboard (English, English)

Standard Operating ProcedurePage 1 of 16 – Effective Date February 1st 2003

Page 2: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

b) The End User Agreement screen will appear. Click Agree to continue

c) The SmartStart Home page will appear. Select the Maintenance tab

d) Select Launch Array configuration Utility option

e) In the Configuration View panel the current configuration can be viewed

f) Under Select the method you would like to use to configure your controller: Select Standard Configuration

g) Highlight the controller in Configuration View. In the right panel under Select a task for: click on Clear Configuration

Standard Operating ProcedurePage 2 of 16 - Effective Date: February 1st 2003

Page 3: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

h) A pop-up window will appear reading “Clearing the configuration will delete all array and logical drives on this controller. Any data on these logical drives will be lost! Press OK to continue, or Cancel to return.” Click OK

i) Click Save under the Controller State panel

j) The following pop-up window will appear:

k) Click OK to continue.

l) Click Exit ACU in the upper right hand corner.

m) This will return you to the SmartStart Maintenance Utilities window – Click Exit in right hand corner.

n) A window will appear reading: “You have decided to exit SmartStart. Click “OK” to eject the SmartStart CD and reboot or “Cancel” to return to SmartStart” – Click OK

Rebooting the server is not always a requirement but there are occasions when clearing the configuration will not take affect until the server has been rebooted.

o) Re-insert SmartStart CD

Step 3. Create Operating System Disk Array

a) If the server has an external drive cabinet, turn it on; then power up the server and insert the SmartStart CD into the server’s CD drive. The system boots and displays a selection list of languages to be used during the SmartStart installation and a request on the keyboard Language.

b) Ensure the radio button labeled English is selected in the “Select the Language to use during the SmartStart process.”

c) In the lower panel labeled “Select the keyboard to be used with this system.” Ensure that English is selected and click Continue. I

d) The “End User Agreement” screen will appear. Click Agree to continue

e) The SmartStart Home page will appear. Select the Maintenance tab

f) Select Launch Array configuration Utility option

g) Under “Select the method you would like to use to configure your controller:” Select Standard Configuration

h) In the”Configuration View” window select the Controller to configure.

i) A new set of options will appear to the right. In the Select a task for: area select Create Array.

Standard Operating ProcedurePage 3 of 16 - Effective Date: February 1st 2003

Page 4: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

j) Select the Hard Drives that will make up the array. Select All can be used if all drives are needed. Once this is completed select OK

k) An array will appear in the “Configuration View” panel with the available disk space noted as Unused Space.

Standard Operating ProcedurePage 4 of 16 - Effective Date: February 1st 2003

Page 5: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

The definition of what RAID version has not occurred yet so expect to see the total disk capacity available at this point.

Step 4. On-line Spare

Note: If an online spare is not required then proceed to Step 5.

a) Ensure that the Array that will have the Online spare is highlighted.

b) In the “Select a task for:” panel select Spare Management

c) A spare management panel will appear with the available disks which can be used for an online spare.

d) Check the radio button for the desired disk and click OK

e) The “Configuration View” window will refresh with Array name with Array A with Spare

Step 5. Create Operating System Logical Drives

a) Ensure that the Array is highlighted in the Configuration View panel. Select Create Logical Drive from the Select a task for: panel.

Standard Operating ProcedurePage 5 of 16 - Effective Date: February 1st 2003

Page 6: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

b) “Create Logical Drive” panel will appear. Available options to modify are: Fault Tolerance, Stripe Size, Size, Max Boot and Array Accelerator.

c) Fault Tolerance should equal RAID 1+0

d) Stripe Size should be set at the default 128KB

e) Set Size at 8192, unless specified differently in the server build sheet

f) Max Boot should be Enabled for the boot partition only.

Maximum Boot Size determines number of sectors used for the logical drive.

When Max Boot is disabled, the logical driver is created with 32 sectors per track netting a 4GB boot partition limit.

When Max Boot is enabled, the logical driver is created with 63 sectors per track netting an 8GB boot partition limit.

g) Array Accelerator will be Disabled for integrated controllers and Enabled for 3200\4200\5300 series controller which contain write back cache.

Write Back Cache resides on the array controller or on an “Add On” module which can be purchased on some of the newer model servers, such as the DL380G3. Write Back Cache enables the controller to store instructions to ROM before it writes to disk thus speeding up disk write operations..

h) Click OK, The configuration view will update with the logical drive created in a highlighted state.

i) Repeat steps 5a through 5h again. When repeating these steps this will not be the boot partition so Max Boot should be Disabled and there is not a hardware limitation on the size of the partition outside of the OS constraints.

Standard Operating ProcedurePage 6 of 16 - Effective Date: February 1st 2003

Page 7: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

j) Once all the logical drives have been created. Click Save in the controller state panel.

k) The following pop-up window will appear:

l) Click OK to continue.

Step 6. Modifying the controller settings

a) In the middle panel the configuration of the controller is outlined. Confirm configuration meets the specification outlined in the build sheet.

Standard Operating ProcedurePage 7 of 16 - Effective Date: February 1st 2003

Page 8: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

b) Select Controller Settings in the Select a task from panel. In this panel you can modify the following: Expand Priority, Rebuild Priority, Cache Ratio, and Surface Scan Delay.

c) Confirm that the radio buttons are set to Low for Expand Priority & Rebuild Priority.

d) Cache ratio can be modified if the controller supports write back cache. The standard for this is 75% Read, 25% Write. If the controller does not support write back cache the only option is Read 100%, Write 0%. Click OK

e) If any changes were made, Click Save in the controller state panel.

f) Click Exit ACU in the upper right hand corner.

g) The SmartStart System Maintenance Utilies will reappear

Standard Operating ProcedurePage 8 of 16 - Effective Date: February 1st 2003

Page 9: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

Step 7. Create Data Volume System Disk Array

a) In the ”Configure” window highlight the Controller which contains the HDs for your data drive.

b) In the main configuration window select the controller that is connected to the external storage array. Select Standard Configuration.

c) A new set of options will appear to the right. In the Select a task for: area select Create Array.

Standard Operating ProcedurePage 9 of 16 - Effective Date: February 1st 2003

Page 10: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

d) Select the Hard Drives that will make up the array. Select All can be used if all drives are needed. Once this is completed select OK

Flashing drive tray LEDs (on the front of the server housing) help locate the drives. Any drive(s) selected in the “Show Physical View” dialog identify themselves by flashing their drive lights.

e) The “Configuration View” window will refresh with Array name Array A.

Step 8. Create Data Volume Logical Drive(s)

a) Ensure that the Array is highlighted in the Configuration View panel. Select Create Logical Drive from the Select a task for: panel.

Standard Operating ProcedurePage 10 of 16 - Effective Date: February 1st 2003

Page 11: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

b) “Create Logical Drive” panel will appear. Available options to modify are: Fault Tolerance, Stripe Size, Size, Max Boot and Array Accelerator. Modify the Fault Tolerance to meet the specification outlined in the build sheet.

c) Fault Tolerance should equal RAID 5

d) Stripe Size should be set at the default 16KB

e) Set Size to the amount specified differently in the server build sheet

f) Max Boot should be Disabled

g) Array Accelerator will be Enabled for 3200\4200\5300 series controller which contain write back cache. Disabled if the storage reside off the integrated controller.

h) Click OK, The configuration view will update with the logical drive created in a highlighted state.

i) Repeat steps 8a through 8h again if more data volumes are required.

j) Once all the logical drives have been created. Click Save in the controller state panel.

k) A pop-up window will appear indicating: “Continuing will commit any changes made to the controller. All Arrays which do not contain at least one logical drive will be deleted. All Spare drives assigned to arrays which contain only RAID 0 logical drives will be removed. Certain operating systems may require a reboot for changes to take effect. Click OK to continue or Cancel to return.

l) Click OK to continue.

Standard Operating ProcedurePage 11 of 16 - Effective Date: February 1st 2003

Page 12: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

Step 9. Modifying the controller settings

a) In the middle panel the configuration of the controller is outlined. Confirm configuration meets the specification outlined in the build sheet.

b) Select Controller Settings in the Select a task from panel. In this panel you can modify the following: Expand Priority, Rebuild Priority, Cache Ratio, and Surface Scan Delay.

c) Confirm that the radio buttons are set to Low for Expand Priority & Rebuild Priority.

d) Cache ratio can be modified if the controller supports write back cache. The standard for this is 75% Read, 25% Write. If the controller does not support write back cache the only option is Read 100%, Write 0%. Click OK

e) If any changes were made, Click Save in the controller state panel.

f) Click Exit ACU in the upper right hand corner.

g) The SmartStart System Maintenance Utilies will reappear

Step 10. ROM Update Utility

a) Select “Launch ROM update Utility” from the SmartStart System Maintenance Utilies” window.

b) The system will scan for the current level and outline any devices that require an update. If updates are identified and the update is needed select the Update Now radio button

Standard Operating ProcedurePage 12 of 16 - Effective Date: February 1st 2003

Page 13: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

c) The Supplemental Disk window is available if there is an update to a system that has been released since the distribution of the SmartStart CD being used. Download the update, place the diskette in the floppy drive and select Use Disk radio button.

d) The Results window outlines the results of the update.

e) Available Firmware outlines what models and devices are included in the SmartStart Release.

f) Once updates have been performed – Click Exit in the upper right corner of the screen.

Step 11. Operating System Selection

a) The SmartStart System Maintenance Utilies will reappear

b) Click the option “What if I don’t see the operating system I want to install?” in the right panel. Do not select the OS type in this step even if it is available.

c) A panel named Changing the selected Operating System will appear. Select Reboot to RBSU.

Standard Operating ProcedurePage 13 of 16 - Effective Date: February 1st 2003

Page 14: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

d) A popup window “You have decided to Reboot to RBSU. Click ‘OK’ to reboot to RBSU or ‘cancel’ to return to SmartStart.” Click OK

e) Server will reboot to RBSU.

f) Eject the Smart Start CD.

Step 12. Operating System Selection – RBSU

a) ROM Based Setup Utility will appear. Select System Options.

b) Select OS Selection

c) Select Operating system Microsoft Windows 2000/Windows .Net – Press Enter

d) Hit ESC to return to ROM Based Setup Utility

Standard Operating ProcedurePage 14 of 16 - Effective Date: February 1st 2003

Page 15: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

e) Select Date and Time and update the date and time to correct values Press Enter to save changes

f) Select Advanced Options, Post F1 Prompts change to Disabled – Press Enter to save changes.

g) In Advanced Options, select Processor Hyper-Threading – See table 11.g to determine is feature should be “Enabled” or “Disabled”.

Table 11.g

Operating System # Processors HyperThreading

Santa Fe 2.x 2 EnabledSanta Fe 2.x Advanced 2 EnabledSanta Fe 2.x 4 DisabledSanta Fe 2.x Advanced 4 Enabled

h) Press ESC to exit Advanced Options

i) Press ESC to exit ROM Based Setup Utility

j) Press F10 to confirm.

Standard Operating ProcedurePage 15 of 16 - Effective Date: February 1st 2003

Page 16: Array Configuration

Configuring SaNTa Fe Servers with SmartStart SaNTa Fe 2.000

Standard Operating ProcedurePage 16 of 16 - Effective Date: February 1st 2003