asbestos survey - lakewood...prepared for report of asbestos survey of curtis block and marlowe...

86
Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue Lakewood, Ohio 44107 Prepared for City of Lakewood 12650 Detroit Avenue Lakewood, Ohio 44107 Prepared by Professional Service Industries, Inc. 5555 Canal Road Cleveland, Ohio 44125 216-447-1335 March 30, 2016 PSI Project Number: 01371612

Upload: others

Post on 07-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Report of

Asbestos Survey

of

Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit

Avenue and 1412 Marlowe Avenue Lakewood, Ohio 44107

Prepared for

City of Lakewood

12650 Detroit Avenue

Lakewood, Ohio 44107

Prepared by

Professional Service Industries, Inc.

5555 Canal Road

Cleveland, Ohio 44125

216-447-1335

March 30, 2016

PSI Project Number: 01371612

Page 2: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. • 5555 Canal Road • Cleveland, Ohio 44125 • Phone 216-445-1335 • Fax 216-642-7008

March 30, 2016 City of Lakewood Department of Planning and Development Lakewood, OH 44107 Attention: Michelle Nochta City Planner Subject: Asbestos Survey Report

Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Ave. and1412 Marlowe Ave. Lakewood, Ohio 44107

PSI Project Number 013711612 Dear Ms. Nochta, Professional Service Industries, Inc. (PSI) performed the Survey of the above-referenced property that you requested. PSI provided its services in general accordance with our agreement dated February 2, 2016. PSI thanks you for choosing us as your consultant for this project. Please contact us at 216-447-1335 if you have any questions or we may be of further service. Respectfully Submitted, PROFESSIONAL SERVICE INDUSTRIES, INC.

Eric Oldroyd James A. Inman Sr. Environmental Technician Department Manager

Page 3: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

TABLE OF CONTENTS

1 EXECUTIVE SUMMARY ..................................................................................................... 1

2 INTRODUCTION ................................................................................................................. 3

2.1 SCOPE OF SERVICES .......................................................................................... 3

2.2 PURPOSE ............................................................................................................. 3

2.3 AUTHORIZATION .................................................................................................. 3

2.4 LIMITATIONS......................................................................................................... 3

2.5 WARRANTY .......................................................................................................... 4 3 GENERAL BUILDING AND SURVEY INFORMATION ....................................................... 5

3.1 BUILDING INFORMATION .................................................................................... 5

3.2 INSPECTION INFORMATION ............................................................................... 6 4 ACM METHODOLOGY ....................................................................................................... 7

4.1 RECORD DOCUMENT REVIEW ........................................................................... 7

4.2 VISUAL INSPECTION PROCEDURES .................................................................. 7

4.3 ASBESTOS SAMPLING PROCEDURES ............................................................... 8

4.4 ASBESTOS ANALYSIS PROCEDURES ................................................................ 8 5 FINDINGS .......................................................................................................................... 10

5.1 RESULTS ............................................................................................................ 10

5.2 INACCESSIBLE AREAS ...................................................................................... 11

5.3 NON-SUSPECT MATERIALS .............................................................................. 11

5.4 QUANTIFICATION ............................................................................................... 11 6 REGULATORY GUIDELINES ........................................................................................... 12

6.1 DEFINITIONS ...................................................................................................... 12

6.2 US-EPA ................................................................................................................ 12

6.3 OSHA ................................................................................................................... 12

6.4 OHIO EPA (OEPA)............................................................................................... 13

6.5 OHIO DEPARTMENT OF HEALTH (ODH) .......................................................... 13

7 CONCLUSIONS & RECOMMENDATIONS ....................................................................... 14

7.1 CONCLUSIONS ................................................................................................... 14

7.2 RECOMMENDATIONS ........................................................................................ 14

TABLES

TABLE 1 – SUSPECT ACM, MARLOWE BUILDING TABLE 2 – SUSPECT ACM, CURTIS BLOCK BUILDING LIST OF APPENDICES

APPENDIX A – LABORATORY ANALYSIS REPORT APPENDIX B – CHAIN OF CUSTODY APPENDIX C – SAMPLE LOCATION DRAWING APPENDIX D – PHOTOGRAPHS APPENDIX E – INSPECTOR & LABORATORY CERTIFICATIONS

Page 4: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

1

1 EXECUTIVE SUMMARY

Professional Service Industries, Inc. (PSI) was retained by the City of Lakewood to conduct a demolition survey for asbestos-containing materials (ACM) at the Marlowe building and a renovation survey for ACM at the Curtis Block building. The project consists of an approximately 18,480 square foot (SF), two-story with basement, retail/apartment building (Curtis Block) and an approximately 2,688 SF, single-story on crawl space, retail/office building (Marlowe). The buildings were not occupied at the time of the survey. The purpose of the investigation and sampling was to provide general information regarding the presence, condition, and estimated quantity of accessible ACM located at the facility. The asbestos inspection and sampling was conducted on February, 23, 24 and March 20, 2016. A total of one hundred thirty-five (135) samples were collected from fifty-seven (57) homogenous areas (HA) of suspect building materials during the survey. The following samples from the survey identified eighteen (18) asbestos containing materials (>1% asbestos) during this investigation: Marlowe Building

03 – 9”x9” black floor tile

04 – 9”x9” red floor tile & associated black mastic

11 – Black mastic associated with 12”x12” floor tile, brown stone pattern

13R – Roofing materials

14 – Exterior window glazing

Curtis Block Building – East side units

16 – Ceiling plaster

17 – Wall plaster

19 – Adhesive, black; on tin roof between upper units

20 – Adhesive, black; on fabric sealant for tin siding between upper units

35 – Green floor tile, unit 14501

36 – Tan floor tile, unit 14501

40 – Red floor tile, unit 14501 basement

41 – TSI pipe insulation, in wall cavities

56 – Roof flashing Curtis Block Building – West side units

31 – Adhesive, black; associated with asphalt sheeting on porch

41 – TSI pipe insulation, in wall cavities

Page 5: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

2

46 – TSI pipe insulation, unit 14509 basement

52 – Brown floor tile, unit 14511 basement

54 – Vapor barrier, under wood floor in units 14511 & 14515

56 – Roof flashing The following materials were not sampled and are assumed to contain asbestos:

Fire doors at 14515 Detroit Ave

This summary does not contain all the information presented in the full report. The report should be read in its entirety to obtain a more complete understanding of the information provided and to aid in any decisions made or actions taken based on this information.

Page 6: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

3

2 INTRODUCTION

2.1 SCOPE OF SERVICES

The scope of services for this project consisted of conducting an asbestos survey including inspection, sampling and analysis of accessible and exposed interior building and roofing materials at the subject facilities. The subject areas of the facilities for this investigation included the entire buildings, interior and exterior. The investigation included a visual inspection of the subject areas, sample collection, PLM sample analysis, quantification of ACM, report preparation and report review.

2.2 PURPOSE

The purpose of this survey was to provide general information for the subject buildings regarding the presence, condition, and quantity of accessible and exposed building materials that may contain asbestos. This asbestos survey was intended to meet the requirements of the US Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAP). The survey included a thorough inspection of all accessible areas.

2.3 AUTHORIZATION

Authorization to perform this work was given on February 2, 2016 by Michelle Nochta, City Planner for Lakewood, Ohio. The project was conducted in accordance with the scope, terms and conditions of PSI proposal number 0137-150707S.

2.4 LIMITATIONS

Due to the continued use of the Curtis Block building, PSI was generally not able to conduct ‘destructive’ sampling such as inside wall cavities or above plaster ceilings: therefore, the inspection was limited to areas that were accessible and exposed. Although PSI made an attempt to identify all areas of ACM, there may exist conditions which were unable to be identified within the scope of this survey. Destructive sampling was generally conducted at the Marlowe building to try to assess inaccessible or concealed materials. The inspector selected representative areas to perform an intrusive evaluation of void spaces within the building or structure. Such inspections were made by creating an opening of sufficient size to determine the presence, condition and quantity of suspect ACM within. Void spaces which were evaluated included locations of suspected pipe or HVAC chases, wall cavities where fireproofing or other ACM was suspected, above finished ceiling systems where ACM was likely to exist, within pipe trenches or within concealed locations.

Page 7: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

4

Although PSI made an attempt to identify all areas of ACM, an exhaustive investigation of void spaces was not included in the scope of services for this project. Conditions may exist that were unknown or unable to be identified within the scope of this survey. Inaccessible is defined as areas of the building that were locked or where admittance was not permitted. It also includes areas/materials that could not be tested (sampled) without destruction of the structure or a portion of the structure, and areas/materials that could not be safely reached by the inspector or inspection team. In the event that access to a portion of the building was not obtained (which otherwise would have been tested), such limitations specifically are identified in the Findings Section of this report. PSI did not sample any system which presented a hazard to the inspection team such as energized electrical systems or within confined spaces. PSI did not collect samples from building elements where the intended use would be compromised by testing.

2.5 WARRANTY

The field and laboratory results reported herein are considered sufficient in detail and scope to determine the presence of accessible and/or exposed suspect ACM for the building structure. PSI warrants that the findings contained herein have been prepared in general accordance with accepted professional practices at the time of its preparation as applied by professionals in the community. Changes in the state of the art or in pertinent regulations cannot be anticipated and have not been addressed in this report. The survey and analytical methods have been used to provide the client with information regarding the presence of accessible and/or exposed suspect ACM existing at the time of the inspection. Test results are valid only for the materials tested. There is a distinct possibility that conditions may exist which could not be identified within the scope of the study or which were not apparent during the site visit. This inspection covered only those areas that were exposed and/or physically accessible to the Inspector. The study is also limited to the information available from the client at the time it was conducted. As directed by the client, PSI did not provide any service to investigate or detect the presence of moisture, mold or other biological contaminants in or around any structure, or any service that was designed or intended to prevent or lower the risk of the occurrence of the amplification of the same. Client acknowledges that mold is ubiquitous to the environment with mold amplification occurring when building materials are impacted by moisture. Client further acknowledges that site conditions are outside of PSI’s control, and that mold amplification will likely occur, or continue to occur, in the presence of moisture. As such, PSI cannot and shall not be held responsible for the occurrence or recurrence of mold amplification. No other warrantees are implied or expressed.

Page 8: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

5

3 GENERAL BUILDING AND SURVEY INFORMATION

3.1 BUILDING INFORMATION

Site Address: Curtis Block – East Side Units 14501, 14505, 14509 Detroit Avenue and second level residential units 1 - 3 Lakewood, Ohio 44107

Facility Construction Date: 1925

Previous Renovation Dates: Unknown

Number of Floors: Two (2) with full basement

Estimated Square Footage: 7,500 sq/ft

Construction Type: Wood Frame and Brick Exterior

Building Use: Three commercial units and three residential units on second floor

Site Address: Curtis Block – West Side Units

14511 & 14515 Detroit Avenue and second level residential units 4 & 5 Lakewood, Ohio 44107

Facility Construction Date: 1925

Previous Renovation Dates: Unknown

Number of Floors: Two (2) with full basement

Estimated Square Footage: 4,900 sq/ft

Construction Type: Wood Frame and Brick Exterior

Building Use: Two commercial units and two residential units on second floor

Site Address: Marlowe Building

1412 Marlowe Avenue Lakewood, Ohio 44107

Facility Construction Date: 1922

Previous Renovation Dates: 1989

Number of Floors: One (1) with crawl space

Estimated Square Footage: 2,688 sq/ft

Construction Type: Wood Frame and Brick Exterior

Building Use: Commercial

Page 9: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

6

3.2 INSPECTION INFORMATION

Asbestos Inspector:

Eric Oldroyd State License # ES34798

James Inman State License # ES33832

Inspection Dates: 2-23-16 2-24-16 3-20-16

Page 10: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

7

4 ACM SURVEY METHODOLOGY

Inspection and sampling procedures were performed in general accordance with the guidelines published by the United States Environmental Protection Agency (US-EPA). The inspection and survey described below was performed by a US-EPA accredited inspectors and Ohio Department of Health (ODH) licensed Asbestos Hazard Evaluation Specialists.

4.1 RECORD DOCUMENT REVIEW

Prior to conducting the visual inspection, PSI reviewed documents provided by the client for information regarding construction history and building materials. The following documents were reviewed as a part of this Asbestos Survey:

No documents were provided.

4.2 VISUAL INSPECTION PROCEDURES

An initial building walkthrough was conducted to determine the presence of suspect ACM that were accessible and/ exposed. The inspection and sampling was limited to those areas and materials that were accessible and did not involve destruction of walls, other building elements, physical barriers, or the structural integrity of the item being tested. Although PSI made an attempt to identify all areas of ACM, there may exist conditions which were unable to be identified within the scope of this survey. Materials which were similar in color, texture, general appearance and which appear to have been installed at the same time were grouped in homogeneous sampling areas. Such materials are termed "homogeneous materials" by the US-EPA. During this walkthrough, the approximate locations of these homogeneous materials were noted. The inspector evaluated each suspect ACM to determine whether the material was friable or non-friable by touching the material, where practical. A friable material is defined as any material able to be crushed, crumbled, pulverized or reduced to a powder by hand pressure when dry. Each material was further assessed for overall condition. Conditions were rated as good, damaged or significantly damaged. PSI’s inspector also identified the US-EPA National Emission Standards for Hazardous Air Pollutants (NESHAP) classification of the material: Regulated asbestos containing material (RACM), Category I non-friable ACM, or Category II non-friable ACM based on the materials current condition. PSI’s inspector provided estimated quantities of the materials positively identified as ACM based on materials that were accessible and exposed.

Page 11: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

8

4.3 ASBESTOS SAMPLING PROCEDURES

Following the walkthrough, the inspectors collected samples of suspect materials. US-EPA guidelines were used to determine the sampling protocol. Sample locations were chosen to be representative of the homogeneous sampling area. While an effort was made to collect samples randomly, samples were taken preferentially from areas which were the least visible to minimize disturbance of the material. Each sample location was sprayed with amended water and was kept wet during the entire sampling process. Samples were collected by coring through the material from the surface down to the base substrate. All layers of the material were extracted and placed into a sample container for transport to the laboratory. Sample containers were sealed and labeled with a unique sample identification number. Where appropriate, sampled materials were sealed with an encapsulant or covered with tape after sampling. PSI is not responsible for restoring the sampled areas to their pre-sampled condition.

4.4 ASBESTOS ANALYSIS PROCEDURES

All samples were analyzed by PSI located at 850 Poplar Street in Pittsburgh, Pennsylvania. The PSI Pittsburgh Asbestos Laboratory is a National Voluntary Laboratory Accreditation Program (NVLAP) Accredited (#101350-0) and an American Industrial Hygiene Association (AIHA) Accredited (#8222) Laboratory. A copy of the Laboratory’s Accreditation Certificate is included in the Appendix. The samples were analyzed for asbestos on a “positive-stop” basis by PLM in accordance with the “EPA Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116 July 1993). Analysis was performed by using bulk samples for visual observation and slide preparation(s) for microscopic examination and identification. The samples were mounted on slides and then analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite, actinolite/tremolite), and fibrous non-asbestos constituents (mineral wool, fiberglass, cellulose, etc.). Asbestos was identified by refractive indices, morphology, color, pleochroism, birefringence, extinction characteristics, and signs of elongation. The same characteristics were used to identify the non-asbestos constituents. The microscopist visually estimated relative amounts of each constituent by determining the volume of each constituent in proportion to the total volume of the sample, using a stereoscope.

Page 12: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

9

The US-EPA method allows samples which are visually determined to have 10% or less asbestos to be quantified using a Point Count procedure. An ocular reticule (cross hair or point array) is used to visually superimpose a point or points on the microscope field of view. A total of 400 points superimposed on either asbestos fibers or non-asbestos matrix material must be counted over at least eight different preparations of representative subsamples. If an asbestos fiber and matrix particle overlap so that a point is superimposed on their visual intersection, a point is scored for both categories. Point counting provides a quantification of the area percent asbestos. Point counted results supersede the results of the visual estimation. It should be noted that some ACM might not be accurately identified or quantified by PLM. As an example, the original fabrication of vinyl floor tiles routinely involved milling of asbestos fibers to extremely small sizes. As a result, these fibers may go undetected under the standard PLM method. Transmission Electron Microscopy (TEM) is recommended for a more definitive analysis of these materials. Laboratory Quality Control Program The PSI Laboratory in Pittsburgh, Pennsylvania, maintains an in-house quality control program. This program involves blind reanalysis of ten percent of all samples, precision and accuracy controls, and use of standard bulk reference materials. In addition, the PSI Laboratory is accredited by NVLAP, which also has quality control procedures inherent in its program.

Page 13: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

10

5 FINDINGS

5.1 RESULTS

A total of one hundred thirty-five (135) samples were collected from fifty-seven (57) homogenous areas (HA) of suspect building materials during the survey. The following samples from the survey identified eighteen (18) asbestos containing materials (>1% asbestos) during this investigation:

Marlowe Building

03 – 9”x9” black floor tile

04 – 9”x9” red floor tile & associated black mastic

11 – Black mastic associated with 12”x12” floor tile, brown stone pattern

13R – Roofing materials

14 – Exterior window glazing

Curtis Block Building – East side units

16 – Ceiling plaster

17 – Wall plaster

19 – Adhesive, black; on tin the roof between the upper units

20 – Adhesive, black; on fabric sealant for tin siding between the upper units

35 – Green floor tile, unit 14501

36 – Tan floor tile, unit 14501

40 – Red floor tile, unit 14501 basement

41 – TSI pipe insulation, in wall cavities

56 – Roof flashing Curtis Block Building – West side units

31 – Adhesive, black; associated with asphalt sheeting on porch

41 – TSI pipe insulation, in wall cavities

46 – TSI pipe insulation, unit 14509 basement

52 – Brown floor tile, unit 14511 basement

54 – Vapor barrier, under wood floor in units 14511 & 14515

56 – Roof flashing The following materials were not sampled due to inaccessibility, safety concerns, or in order to avoid compromising their integrity, and are assumed to be ACM:

Fire doors in 14515 Detroit Ave.

Page 14: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

11

The laboratory analysis report, chain of custody, sample location drawing, material location drawing, photographs and certifications are included in the Appendices. Table 1 attached to this report lists the suspect ACM observed throughout the Marlowe building and Table 2 lists the suspect ACM observed throughout the Curtis block building. The tables list the suspect material sample ID#, general location, laboratory results, condition, friability, NESHAP category, and estimated quantity of ACM materials.

5.2 INACCESSIBLE AREAS

These areas will require an asbestos inspection prior to any demolition or renovation activities within the areas.

Curtis Block Building, Interior wall cavities

Curtis Block East Side Building, materials under wood flooring

5.3 NON-SUSPECT MATERIALS

The following materials were observed but are considered ‘non-suspect’ ACM due to their composition and were not sampled.

Wood, stone or metal components

Concrete and masonry components

Fiberglass pipe insulation

5.4 QUANTIFICATION

Quantification of suspect ACM was conducted using visual estimation by a licensed asbestos inspector. This visual estimation was performed in accordance with generally accepted practices in the asbestos industry based on materials that were accessible and exposed. These values are sufficiently accurate for the purpose of documenting the presence of asbestos within its space for the purpose of identifying abatement control conditions or for general policy considerations. Actual quantities may differ between visually estimated values and physical measurements. If a licensed asbestos abatement contractor is engaged to remove asbestos containing materials, the abatement contractor is responsible for verifying reported quantities of ACM.

Page 15: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

12

6 REGULATORY GUIDELINES

6.1 DEFINITIONS

ACM - The US-EPA and Occupational Safety and Health Administration (OSHA) consider a material to be asbestos-containing if at least one sample from the homogeneous area shows asbestos in an amount greater than 1%. Friable ACM - The US-EPA defines friable ACM as any ACM that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. Point Count - If a material is found to contain 10% or less asbestos via visual estimation, it can be treated as non-asbestos-containing per US-EPA Regulations only if verified to contain 1% or less asbestos by the Point Count Quantification Procedure. If not point counted, a sample in which asbestos was visually detected and estimated (including trace to ≤1%) must be assumed to be greater than 1% and treated as ACM. Please refer to the laboratory analyses for a more detailed description of the microscopic analysis of individual samples.

6.2 US-EPA

US-EPA classifies ACM into three categories:

Category I Nonfriable (Cat I NF) includes asbestos-containing packings, gaskets, resilient floor covering and asphalt roofing products

Category II Nonfriable (Cat II NF) includes any ACM, excluding Category I NF, which cannot be crumbled, pulverized or reduced to powder by hand pressure when dry

Regulated ACM (RACM) – means any friable ACM, including:

Cat I NF ACM that has become friable

Cat I NF ACM that will be or has been subjected to sanding, grinding, cutting or abrading

Cat II NF ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation activities.

6.3 OSHA

OSHA requires all suspect materials to be analyzed by layer, even materials such as drywall/joint compound, which may sometimes be composited per the US-EPA. If any layer contains asbestos in a concentration >1%, the material is considered an ACM.

Page 16: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

13

OSHA has a classification system (I thru IV) for ACM depending on the type of material and the disturbance. Briefly, ‘Class I’ work is defined as activities involving the removal of ACM or presumed ACM (PACM) that is thermal system insulation (TSI) and surfacing materials. ‘Class II’ activities involve removal of ACM/PACM other than TSI or surfacing material. ‘Class III’ work includes repair and maintenance operations which are likely to disturb ACM/PACM, and ‘Class IV’ work includes maintenance and custodial activities during which employees contact but do not disturb ACM/PACM. Materials where asbestos is detected, but where point counting is conducted and determined that the concentration is ≤1% asbestos, are not considered to be ACM by OSHA. However, these materials are considered unclassified asbestos work per OSHA. Some OSHA work control practices and prohibitions will still apply, with the extent depending on whether the worker’s exposure to airborne asbestos exceeds the OSHA PEL. Additional details of the OSHA asbestos regulations related to the construction industry can be found in 29 CFR part 1926.1101.

6.4 OHIO EPA (OEPA)

The OEPA regulations are consistent with the US-EPA’s NESHAP standards with the exception of the following rule changes:

Friable ACM: Any Cat I or Cat II ACM that becomes damaged from either deterioration or attempts at removal or abatement resulting in small fragments the size of four square inches or less shall be considered friable or RACM.

Disposal: OEPA requires that in addition to RACM, all Cat II materials to be disposed of at a regulated asbestos landfill.

6.5 OHIO DEPARTMENT OF HEALTH (ODH)

ODH governs asbestos certification and licensure in Ohio under Chapter 3710 of the Ohio Revised Code and Chapter 3701-34 of the Ohio Administrative Code. An Asbestos Hazard Abatement Activity is defined by ODH as any activity involving the removal, renovation, enclosure, repair or encapsulation of reasonably related friable ACM in an amount greater than fifty linear feet or fifty square feet. Asbestos Hazard Abatement Activities require:

Abatement activities be conducted by a licensed Asbestos Hazard Abatement Contractor using licensed Asbestos Hazard Abatement Workers

A written Asbestos Hazard Abatement Project Agreement

A written Prior Notification of Asbestos Hazard Abatement form be submitted to ODH 10 business days prior to the start of any asbestos hazard abatement project

Page 17: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Curtis Block & Marlowe Buildings Survey Report March 30, 2016 PSI Project Number: 01371612

14

7 CONCLUSIONS & RECOMMENDATIONS

7.1 CONCLUSIONS

Regulated Asbestos Containing Materials (RACM) were identified at the subject site. Category I Asbestos Containing Materials (ACM) were identified at the subject site. Assumed Asbestos Containing Materials (ACM) were identified at the subject site.

7.2 RECOMMENDATIONS

ACM should be maintained in a good, non-damaged condition and periodically inspected through use of an O&M program. Damaged or significantly damaged ACM should be repaired, encapsulated, enclosed or removed. RACM must be properly removed by a licensed asbestos abatement contractor prior to renovations or demolition that would disturb the material. Federal, State and Local regulations and guidelines should be strictly adhered to when removing the ACM. In addition, prior to any future maintenance, renovation or demolition activities, any areas that were noted as being inaccessible during this project, or any concealed areas, such as wall cavities and ceiling plenums, where suspect ACM are discovered, will require testing or can be treated as assumed ACM unless tested and found to be non-ACM survey for ACM. The Ohio EPA regulations allows Category I non-friable and some Category II non-friable ACM to remain in place during demolition, unless that material becomes damaged from either deterioration or attempts at removal or abatement resulting in small fragments the size of four square inches or less, which is considered RACM. RACM must be properly removed prior to demolition. If Category I non-friable ACM is not removed prior to demolition the generated debris cannot be recycled or used as clean-fill but may be disposed of at a construction and demolition landfill. If Category II non-friable ACM is not removed prior to demolition, the generate debris must be disposed of at an EPA approved asbestos waste disposal site. Materials verified to contain low concentrations of asbestos (trace to 1%) by the point count method are not considered ACM, and are not regulated by the US EPA; however, some OSHA regulations will still apply based on the employee’s airborne exposure.

Page 18: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

TABLES

Page 19: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

TABLE 1 – MARLOWE BUILDING SUSPECT ACM

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

01 (A-B)

2’x4’ Suspended ceiling tile, pinhole & random fissures South side section - - NAD - -

02 (A-C)

2’x4’ Suspended ceiling tile, round & oblong holes North and center units - - NAD - -

03 (A-B)

9”x9” Floor tile, black w/tan

South side section NF Good

5% CH

CAT I 600 sf Mastic, black NAD

04 (A-B)

9”x9” Floor tile, red

South side front entrance NF Good

7% CH

CAT I 50 sf Mastic, black 5% CH

05 (A-B)

Vapor barrier, black South and center section - - NAD - -

06 (A-B)

Carpet mastic, yellow North sections - - NAD - - -

07 (A)

Plaster, white

Walls, throughout - -

NAD

- - Texture, grey NAD

08 (A-B)

Plaster, white

Ceiling, throughout

- - NAD -

- Plaster, grey - - <1% CH, PT -

09 (A-B)

Drywall

South sections - - NAD - - Joint compound

10 (A-B)

Drywall North sections - - NAD - -

Joint compound

Page 20: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

11 (A-E)

12”x12” Floor tile, brown stone pattern

South-center section

NF good NAD CAT I 600 sf

Mastic, black NF good 5% CH CAT I 600 sf

12 (A&B)

Cove base, brown North sections - - NAD - -

Adhesive, brown

13R (A-B) Roofing Roof NF Good 3% CH CAT I 2,400 sf

13F (A-B)

Roof flashing Roof - - NAD - -

14 (A-B)

Window glazing Exterior rear windows F Poor 2% CH RACM 4 ea.

Notes: 1 F = Friable

NF = Non-friable 2 Cond. = Condition of Materials 3 NAD = No Asbestos Detected CH = Chrysotile PT = Point Count 4 NESHAP Category

RACM = Regulated ACM Cat I = Category I Non-Friable ACM Cat II = Category II Non-Friable ACM

Page 21: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

TABLE 2 – CURTIS BLOCK BUILDING SUSPECT ACM

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

15 (A&B)

12”x12” Floor tile, off-white w/grey blotch pattern Kitchen, Units #1, 2 & 5 - - NAD - -

Mastic, yellow

16 (A-E)

Plaster, grey East side units 2nd floor, ceiling

NF Good 3% CH

RACM 3,750 sf Plaster, white NAD

17 Plaster, grey East side units, walls NF Good

3% CH RACM 13,044 sf

Plaster, white NAD

18 (A&B)

Mortar Behind fire place inserts Units #1,2 & 3

- - - - -

19 (A&B)

Adhesive, black Exterior on tin siding between units 1&2 and 2&3

F poor 5% CH RACM 420 sf

20 (A&B)

Asphaltic coating, black On tin roofing between units 1&2 and 2&3

F Poor 5% CH RACM 210 sf

21 (A&B)

Ceiling tile, 1’x1’, white & textured finish

2nd floor stairwells - - NAD - -

22 A

Cable housing, exterior On porch between 1st & 2nd floor - - NAD - -

23 (A&B)

12”x12” Floor tile, Lt. brown w/pattern

Kitchen, unit #3 - - NAD

- -

Mastic, yellow NAD

24 (A-E)

Plaster, grey West side units 2nd floor, ceiling - -

NAD - -

Plaster, white NAD

Page 22: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

25 (A&B)

Plaster, grey West side units, walls -

<1% CH PT - -

Plaster, white NAD

26 (A&B)

2’x4’ Suspended ceiling tile, white

Living room, unit #4 - - NAD - -

27 (A&B)

12”x12” Floor tile. Yellow w/pattern Kitchen, unit #4 - - NAD - -

Mastic, yellow

28 (A&B)

Ceiling tile, 1’x1’, white & smooth finish

Kitchen, 2nd level - - NAD - -

29 (A&B)

Window glazing West side units - - NAD - -

30 (A&B)

2’x4’ Suspended ceiling tile, white, pin & random holes

Living room, unit #4 - - NAD - -

31 (A&B)

Rolled asphalt sheeting West side porch NF Good

NAD CAT I 450 sf

Adhesive, black 5% CH

32 (A&B)

Window glazing East side units - - NAD - -

33 (A&B)

Ceiling tile, 1’x1’, white & pinhole

#14501 entrance - - NAD - -

34 (A&B)

12’x12’ Floor tile, brown wood pattern

#14501 front sales area - - NAD - -

Mastic, yellow

35 (A&B)

12’x12’ Floor tile, green

#14501 front sales area NF Good

7% CH

CAT I 1,010 sf Mastic, black NAD

Page 23: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

36 (A&B)

12’x12’ Floor tile, tan w/brown & white #14501 front sales area NF Good

5% CH CAT I 1,010 sf

Mastic, black NAD

37 (A&B)

Vapor barrier, black #14501 front sales area - - NAD - -

38 (A&B)

Cove base, brown #14501 front sales area - -

NAD - -

Mastic, yellow NAD

39 (A&B)

Drywall #14501 basement - -

NAD - -

Joint compound NAD

40 (A&B)

12”x12” Floor tile, red #14501 basement, under carpet

NF Good 3% CH

CAT I 400 sf Mastic, yellow NAD

41 (A&B)

Thermal system pipe wrap

#14501 basement F Poor 50% CH RACM 5 lf (observed)

42 (A&B)

12”x12” Floor tile, maroon #14505 - -

NAD - -

Mastic, yellow NAD

43 (A&B)

2’x4’ Suspended ceiling tile, white, pin & random fissures

#14505 - - NAD - -

44 (A&B)

Floor overlay, brown #14509 - - NAD - -

45 (A&B)

Drywall #14505 basement - -

NAD - -

Joint compound NAD

46 (A)

Thermal system insulation, MAG

#14509 basement F Poor NAD RACM 1 lf (observed)

47 (A&B)

12”x12” Floor tile, off-white w/tan pattern #14515 - -

NAD - -

Mastic, yellow NAD

Page 24: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Suspect ACM Tables March 30, 2016 Curtis Block & Marlowe Buildings Survey Report PSI Project Number 01371612

HA & (Sample #)*

Material Description General Material Location F / NF 1

Cond.2

Asbestos Content3

EPA NESHAP

Cat 4

Estimated Quantity

48 (A&B)

12”x12” Floor tile, off-white w/grey pattern #14511, first floor - -

NAD - -

Mastic, yellow NAD

49 (A&B)

Carpet mastic, yellow #14511, first floor - - NAD - -

50 (A&B)

Cove base, black #14511, first floor - - NAD - -

Mastic, yellow

51 (A&B)

Drywall #14511, first floor - -

NAD - -

Joint compound

52 (A&B)

12”x12” Floor tile, brown #14511, basement entrance NF Good

3% CH CAT I 35 sf

Mastic, yellow NAD

53 (A&B)

Drywall, no joint compound #14515 basement - - NAD - -

54 (A&B)

Vapor barrier, white #14515 & #14511 Under wood flooring

F Good 50% CH RACM 2,500 sf

55 (A&B)

Asphaltic roof materials Roofing - - NAD - -

56 (A&B)

Asphaltic roof flashing Roof flashing NF Good 4% CH CAT I 2,000 sf

57 (A&B)

Window Caulking Front Windows - - NAD - -

Notes: 1 F = Friable

NF = Non-friable 2 Cond. = Condition of Materials 3 NAD = No Asbestos Detected CH = Chrysotile PT = Point Count

4 NESHAP Category RACM = Regulated ACM Cat I = Category I Non-Friable ACM Cat II = Category II Non-Friable ACM

Page 25: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDICES

Page 26: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDIX A – LABORATORY ANALYSIS REPORT

Page 27: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncMarlowe Building

Date Received: 2/29/2016 Date Completed: 3/7/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

1412 Marlowe, Lakewood

Date Reported: 3/7/2016

Page: 1 of 4Analyst: Preston Hunt Work Order: 1602703

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A01A (1) White, Ceiling Tile, Homogeneous 10% Fibrous Glass

60% Cellulose FiberNO ASBESTOS DETECTED

002A01B (1) White, Ceiling Tile, Homogeneous 10% Fibrous Glass

60% Cellulose FiberNO ASBESTOS DETECTED

003A02A (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

004A02B (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

005A03A (1) Black, Floor Tile, Homogeneous Chrysotile5% None Reported

(2) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

006A03B (1) Black, Floor Tile, Homogeneous Chrysotile5% None Reported

(2) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

007A04A (1) Red, Floor Tile, Homogeneous Chrysotile7% None Reported

(2) Black, Mastic, Homogeneous Chrysotile5% None Reported

008A04B Sample Not Tested

009A05A (1) Black, Vapor Barrier, Homogeneous 70% Cellulose FiberNO ASBESTOS DETECTED

010A05B (1) Black, Vapor Barrier, Homogeneous 70% Cellulose FiberNO ASBESTOS DETECTED

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 28: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 2 of 4Analyst: PH Work Order: 1602703

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

011A06A (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

012A06B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

013A07A (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

No Texture

014A07B (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(3) White, Texture, Homogeneous NO ASBESTOS DETECTED None Reported

015A07C (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

016A07D (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

No Texture

017A07E (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

018A08A (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

No Texture

019A08B (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 3% Hair

Chrysotile< 1%

No Texture

020A08C (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 3% Hair

Chrysotile< 1%

No Texture

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 29: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 3 of 4Analyst: PH Work Order: 1602703

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

021A08D (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 3% Hair

Chrysotile< 1%

No Texture

022A08E (1) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Gray, Plaster, Homogeneous 3% Hair

Chrysotile< 1%

No Texture

023A09A (1) White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

024A09B (1) White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

025A10A (1) Off-White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

026A10B (1) Off-White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

027A11A (1) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Black, Mastic, Homogeneous Chrysotile5% None Reported

028A11B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(3) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

029A12A (1) Brown, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Brown, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

030A12B (1) Brown, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Brown, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 30: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 4 of 4Analyst: PH Work Order: 1602703

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

031A13RA (1) Black, Roofing, Homogeneous 10% Cellulose Fiber

10% Fibrous Glass

Chrysotile3%

032A13RB Sample Not Tested

033A13FA (1) Black, Flashing, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

10% Fibrous Glass

034A13FB (1) Black, Flashing, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

10% Fibrous Glass

035A14A (1) Gray, Caulking, Homogeneous Chrysotile2% None Reported

036A14B Sample Not Tested

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 31: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncMarlowe Building

Date Received: 3/24/2016 Date Completed: 3/25/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

1412 Marlowe, Lakewood

Date Reported: 3/25/2016

Original WO# 1602703

Page: 1 of 1Analyst: Daniel Anderson Work Order: 1603627

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A8B (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

002A8C (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

003A8D (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

004A8E (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 32: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncCurtis Block

Date Received: 2/29/2016 Date Completed: 3/4/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

1412 Marlowe, Lakewood

Date Reported: 3/4/2016

Page: 1 of 8Analyst: Preston Hunt Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A15-A (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

002A15-B (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

003A16-A (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(3) White, Texture, Homogeneous NO ASBESTOS DETECTED None Reported

004A16-B (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(3) White, Texture, Homogeneous NO ASBESTOS DETECTED None Reported

005A16-C (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

(3) White, Texture, Homogeneous NO ASBESTOS DETECTED None Reported

006A16-D (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

007A16-E (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 33: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 2 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

008A17-A (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

009A17-B (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

010A17-C (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

011A17-D (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

012A17-E (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

013A17-F (1) Gray, Plaster, Homogeneous Chrysotile3% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

014A17-G (1) Gray, Plaster, Homogeneous 2% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

015A18-A (1) Gray, Mortar, Homogeneous NO ASBESTOS DETECTED None Reported

016A18-B (1) Gray, Mortar, Homogeneous NO ASBESTOS DETECTED None Reported

017A19-A (1) Black, Adhesive, Homogeneous Chrysotile5% None Reported

018A19-B (1) Black, Adhesive, Homogeneous Chrysotile5% None Reported

019A20-A (1) Black, Coating, Homogeneous 3% Cellulose FiberNO ASBESTOS DETECTED

020A20-B (1) Black, Coating, Homogeneous Chrysotile5% None Reported

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 34: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 3 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

021A21-A (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

022A21-B (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

023A22-A (1) Gray, Other, Homogeneous 30% CottonNO ASBESTOS DETECTED

Cable Housing

024A23-A (1) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

025A23-B (1) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

026A24-A (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

027A24-B (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

028A24-C (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

029A24-D (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

030A24-E (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

031A25-A (1) Gray, Plaster, Homogeneous Chrysotile< 1% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 35: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 4 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

032A25-B (1) Gray, Plaster, Homogeneous Chrysotile2% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

033A25-C (1) Gray, Plaster, Homogeneous Chrysotile< 1% None Reported

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

034A25-D (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

035A25-E (1) Gray, Plaster, Homogeneous 2% HairNO ASBESTOS DETECTED

(2) White, Plaster, Homogeneous NO ASBESTOS DETECTED None Reported

No Texture

036A26-A (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

037A26-B (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

038A27-A (1) White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

039A27-B (1) White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

040A28-A (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

041A28-B (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

042A29-A (1) Gray, Glazing, Homogeneous NO ASBESTOS DETECTED None Reported

043A29-B (1) Beige, Glazing, Homogeneous NO ASBESTOS DETECTED None Reported

044A30-A (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 36: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 5 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

045A30-B (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

046A31-A (1) Black, Roofing, Homogeneous 10% Synthetic FiberNO ASBESTOS DETECTED

(2) Black, Adhesive, Homogeneous Chrysotile5% None Reported

047A31-B (1) Black, Roofing, Homogeneous 10% Synthetic FiberNO ASBESTOS DETECTED

(2) Black, Adhesive, Homogeneous Chrysotile5% None Reported

048A32-A (1) Gray, Glazing, Homogeneous NO ASBESTOS DETECTED None Reported

049A32-B (1) White, Glazing, Homogeneous NO ASBESTOS DETECTED None Reported

050A33-A (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

051A33-B (1) White, Ceiling Tile, Homogeneous 100% Cellulose FiberNO ASBESTOS DETECTED

052A34-A (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(3) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

053A34-B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Brown, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(3) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

054A35-A (1) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Green, Floor Tile, Homogeneous Chrysotile7% None Reported

(3) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

055A35-B (1) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Green, Floor Tile, Homogeneous Chrysotile7% None Reported

(3) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

056A36-A (1) Tan, Floor Tile, Homogeneous Chrysotile2% None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

No Carpet Mastic or Black Mastic

057A36-B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Tan, Floor Tile, Homogeneous Chrysotile5% None Reported

(3) Black, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

058A37-A (1) Black, Vapor Barrier, Homogeneous 70% Cellulose FiberNO ASBESTOS DETECTED

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 37: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 6 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

059A37-B (1) Black, Vapor Barrier, Homogeneous 70% Cellulose FiberNO ASBESTOS DETECTED

060A38-A (1) Brown, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

061A38-B (1) Brown, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

062A39-A (1) White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

063A39-B (1) White, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

064A40-A (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Red, Floor Tile, Homogeneous Chrysotile3% None Reported

(3) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

065A40-B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Red, Floor Tile, Homogeneous Chrysotile3% None Reported

(3) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

066A41-A (1) Gray, Insulation, Homogeneous 20% Cellulose Fiber

Chrysotile50%

067A41-B Sample Not Tested

068A42-A (1) Purple, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

069A42-B (1) Purple, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

070A43-A (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

071A43-B (1) White, Ceiling Tile, Homogeneous 30% Fibrous Glass

40% Cellulose FiberNO ASBESTOS DETECTED

072A44-A (1) Brown, Flooring, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 38: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 7 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

073A44-B (1) Brown, Flooring, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

074A45-A (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

075A45-B (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

076A46-A (1) Gray, Insulation, Homogeneous 10% Cotton

Chrysotile70%

077A47-A (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

078A47-B (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

079A48-A (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

080A48-B (1) Off-White, Floor Tile, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

081A49-A (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

082A49-B (1) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

083A50-A (1) Black, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

084A50-B (1) Black, Covebase, Homogeneous NO ASBESTOS DETECTED None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

085A51-A (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

086A51-B (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

(2) White, Joint Compound, Homogeneous

NO ASBESTOS DETECTED None Reported

087A52-A (1) Brown, Floor Tile, Homogeneous Chrysotile3% None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 39: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Page: 8 of 8Analyst: PH Work Order: 1602688

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

088A52-B (1) Brown, Floor Tile, Homogeneous Chrysotile3% None Reported

(2) Yellow, Mastic, Homogeneous NO ASBESTOS DETECTED None Reported

089A53-A (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

090A53-B (1) Gray, Drywall, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

091A54-A (1) White, Vapor Barrier, Homogeneous 20% Cellulose Fiber

Chrysotile50%

092A54-B Sample Not Tested

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 40: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncCurtis Block

Date Received: 3/17/2016 Date Completed: 3/21/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

1412 Marlowe, Lakewood

Date Reported: 3/21/2016

Original WO# 1602688

Page: 1 of 1Analyst: Daniel Anderson Work Order: 1603427

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A25-B (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 41: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncCurtis Marlowe

Date Received: 3/21/2016 Date Completed: 3/23/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

Date Reported: 3/23/2016

Page: 1 of 1Analyst: DA Work Order: 1603499

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A55A (1) Black, Roofing, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

10% Fibrous Glass

002A55B (1) Black, Roofing, Homogeneous 10% Cellulose FiberNO ASBESTOS DETECTED

10% Fibrous Glass

003A56A (1) Black, Flashing, Homogeneous Chrysotile4% None Reported

004A56B Sample Not Tested

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 42: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncCurtis Block

Date Received: 3/23/2016 Date Completed: 3/24/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

1412 Marlowe, Lakewood

Date Reported: 3/24/2016

Original WO# 1602688

Page: 1 of 1Analyst: Daniel Anderson Work Order: 1603611

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A25-A (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

002A25-C (1) Gray, Plaster, Homogeneous < 1% CHRYSOTILE (PT) None Reported

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Mary Cantley

Page 43: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS

TESTED FOR: PSI, IncMarlowe Building

Date Received: 3/30/2016 Date Completed: 3/30/2016

5555 Canal Road Cleveland, OH 44125Attn: Eric Oldroyd

Project ID: 01371612

Date Reported: 3/30/2016

Page: 1 of 1Analyst:Dan Anderson Work Order: 1603769

Lab ID (Layer)

AsbestosContent

(Percent and Type)

Non-asbestosFibers

(Percent and Type)

Client ID Sample Description(Color, Texture, Etc.)

Analyst's Comment

001A57A (1) Gray, Caulking, Homogeneous NO ASBESTOS DETECTED None Reported

002A57B (1) Gray, Caulking, Homogeneous NO ASBESTOS DETECTED None Reported

Report Notes: (PT) Point Count Results

Quantitation is based on a visual estimation of the relative area of bulk sample components, unless otherwise noted in the "Comments" section of this report. The results are valid only for the item tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Method used: E.P.A. Method for the Determination of Asbestos in Bulk Building Materials (EPA / 600/R-93/116 July 1993). Polarized Light Microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos containing. Samples will be disposed of within 30 days unless notified in writing by the client. No part of this report may reproduced, except in full, without written permission of the laboratory. The reporting limit is 1% by weight. NVLAP Lab Code 101350-0.

Respectfully submitted,

Approved Signatory

PSI, Inc.

Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220 Phone 412/922-4010 Fax 412/922-4014

Melanie Smith

Page 44: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDIX B – CHAIN OF CUSTODY

Page 45: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 46: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 47: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 48: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 49: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 50: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 51: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 52: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 53: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 54: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDIX C – SAMPLE LOCATION DRAWING

Page 55: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

18a

X

Stairwell 16b Bedroom

X

X

17a

Bathroom

16a

X

Kitchen Bedroom

X

15a

X 32a

PROJECT MGR

J. Inman DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS & MARLOWE DATE:

2-23-16 PROJECT NO.:

01371612 DRAWING NO.

ONE

LEGEND: Not to Scale

X = Sample location

Unit #1

Page 56: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

18b

X

Shared

Stairwell

Bedroom

16d

X

X

Bathroom 32b

15b

Kitchen X

Bedroom

PROJECT MGR

J. Inman DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS & MARLOWE DATE:

2-23-16 PROJECT NO.:

01371612 DRAWING NO.

TWO

LEGEND: Not to Scale

X = Sample location

Unit #2

Page 57: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Closet

Shared

17c Stairwell

X

Bedroom

X

16e

21a

Bathroom

X

20b

X

17b

23a

Bedroom Kitchen

22a X

PROJECT MGR

J. Inman DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS & MARLOWE DATE:

2-23-16 PROJECT NO.:

01371612 DRAWING NO.

THREE

LEGEND: Not to Scale

X = Sample location

Unit #3

Page 58: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Shared

Stairwell

Bedroom

24b

X

25a

X

Bathroom

X

24a

26a

X

26b

X

24d

Kitchen

X

X 21b

28a

X Bedroom

27a

PROJECT MGR

J. Inman DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS & MARLOWE DATE:

2-23-16 PROJECT NO.:

01371612 DRAWING NO.

FOUR

LEGEND: Not to Scale

X = Sample location

Unit #4

Page 59: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Closet

Shared

Stairwell

Bedroom X

24c

Bathroom X

25b

30b

X 30a

X

X

24e

Bedroom Kitchen

X

29a

PROJECT MGR

J. Inman DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS & MARLOWE DATE:

2-23-16 PROJECT NO.:

01371612 DRAWING NO.

FIVE

LEGEND: Not to Scale

X = Sample location

Unit #5

Page 60: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Basement Level First Floor

33a

X

X

17e X

40b

Stairwell X

X 34a

Stairwell 41a

X

34b

35a

36a

37a

X

39a

X

36b

X 38a

40a X

39b

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

SIX

LEGEND: Not to Scale X = Sample ID & Location

14501 Detroit Ave.

First floor and basement levels

Notes:

N

Page 61: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

14509 14505

X

17f

Stairwell

44b X

X 42a

36b

X

44a X

42b

X

17g

N

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

SEVEN

LEGEND: Not to Scale X = Sample ID & location

14505 & 14509 Detroit Ave

First Floor Levels

Notes:

Page 62: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

14509 14505

X

46a Stairwell

X 45b

X

45a

Furnace

X 41b

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

EIGHT

LEGEND: Not to Scale X = Sample ID & location

14505 & 14509 Detroit Ave

Basement Levels

Notes:

Page 63: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

14515 14511

X

47b

50a

X

X

48a

X

48a

X

47a X

X 50b

51a 49b

X X

X 48b

51b

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

NINE

LEGEND: Not to Scale X = Sample ID & location

14511 & 14515 Detroit Ave

First Floor Levels

Notes:

Page 64: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

14515 14511

25c

X 25c X

54c X X 54a

X 25b 25d X

53b 53a

X X

52b

X

X 52a

X 29b

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

TEN

LEGEND: Not to Scale X = Sample ID & location

14511 & 14515 Detroit Ave

Basement Levels

Notes:

Page 65: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

N

7a

X 1a X X

X 11b X 3a

12b 5b 8a 4 a&b

X

X

X 2a 6b

12a X

X

X 6a

8d 9b X X

X X 8b 9a

8e X

10b 7c

X X

X 1b

7e

X

2b 8c

X

X

10a 7d 7b

X X

X X

14b 14a

PROJECT MGR

J. Inman

DRAWN BY

E. Oldroyd

PROJECT NAME:

CURTIS AND MARLOWE DATE: 2-23-16

PROJECT NO.:

01371612 DRAWING NO.

ELEVEN

LEGEND: Not to Scale X = Sample ID & location

1412 Marlowe Ave

Notes:

Page 66: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDIX D – PHOTOGRAPHS

Page 67: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Marlowe Building

Remarks: Sample ID# 03

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Marlowe Building

Remarks: Sample ID# 04

Page 68: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Marlowe Building

Remarks: Sample ID# 11

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Marlowe Building

Remarks: Sample ID# 13R

Page 69: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Marlowe Building

Remarks: Sample ID# 14

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 16

Page 70: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 17

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 19

Page 71: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 20

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 31

Page 72: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 41

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 54

Page 73: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 52

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 36

Page 74: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 35

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Assumed asbestos containing fire door

Page 75: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Professional Service Industries, Inc. 5555 Canal Road, Cleveland, Ohio 44125 Phone (216) 447-1335 Fax (216) 642-7008

Date of Photo: 2-23-16 PSI Project No.: 01371612

Client: City of Lakewood Project Name: Curtis-Marlowe Buildings

Address: Curtis Block Building

Remarks: Sample ID# 56

Page 76: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

APPENDIX E – INSPECTOR & LABORATORY CERTIFICATIONS

Page 77: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 78: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 79: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 80: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 81: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 82: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue
Page 83: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

AIHA Laboratory Accreditation Programs, LLC

acknowledges that

PSI - Professional Service Industries, Inc. 850 Poplar Street, Pittsburgh, PA 15220

Laboratory ID: 100373 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:

LABORATORY ACCREDITATION PROGRAMS

INDUSTRIAL HYGIENE Accreditation Expires: 04/01/2016 ENVIRONMENTAL LEAD Accreditation Expires: 04/01/2016 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: 04/01/2016 FOOD Accreditation Expires: UNIQUE SCOPES Accreditation Expires: Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.

Gerald Schultz, CIH Chairperson, Analytical Accreditation Board

Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC

Revision 14: 03/26/2014 Date Issued: 03/31/2014

Page 84: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue

Effective: 03/12/2013 100373_Scope_IHLAP_2014_03_31 Page 1 of 1

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION PSI - Professional Service Industries, Inc. Laboratory ID: 100373 850 Poplar Street, Pittsburgh, PA 15220 Issue Date: 03/31/2014 The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

Industrial Hygiene Laboratory Accreditation Program (IHLAP)

Initial Accreditation Date: 03/01/1987

A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org

IHLAP Scope Category

Field of Testing (FoT)

Technology sub-type/ Detector

Published Reference Method/Title of In-house

Method

Method Description or Analyte

(for internal methods only)

Asbestos/Fiber Microscopy Core

Phase Contrast Microscopy (PCM) NIOSH 7400

Page 85: Asbestos Survey - Lakewood...Prepared for Report of Asbestos Survey of Curtis Block and Marlowe Buildings 14501, 14505, 14509, 14511 & 14515 Detroit Avenue and 1412 Marlowe Avenue