astasthpd series 2 & 3 contact row signal · pdf file2 & 3 contact row signal...
TRANSCRIPT
![Page 1: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/1.jpg)
ASTASTHPD Series
2 & 3 Contact Row Signal Connectors
Product descriptionStandard-density signal PCB connector (2,54 mm x 2,54 mm pitch)
ApprovalsBS 9525 N0001, Mil-C-55302 & ESA SCC 3401
Features • Large number of pin count options• Large number of termination options• Large number of guide options• High reliability contacts
Advantages Versatile range covering Cardfile, Stacking andFlying-lead applications
Markets Mil/Aero Space, Marine, Rail & Industrial
37APRIL 2005
The following unshrouded sizes are qualified to:MIL-C-55302/159 and 162 17, 29, 41, 53 and 65 position
MIL-C-55302/160 and 163 72, 84, 96 and 120 position
MIL-C-55302/161 and 164 160 position
BS 9525 N0001/1982 17, 29, 33, 41, 53, 65, 72, 84, 96 and 120 position
BS 9525 F0041/1989 17, 29, 33, 41, 53, 65, 72, 84, and 96 position
Incorporates BS 9525 N0001 testing but includes Gunfire vibration test.
BS 9525 F0053/1995 Additional specification to BS 9525 N0001 with extra terminations.
BS 9525-F-0016/1995 48, 62, 80, 98, 119, 149 and 160 (Solid insulator) position
The following shrouded sizes are qualified to:BS 9525-F-0016/1995 48, 98, 119 and 160 position
Space qualification: ESA/SCC 5401/016/017
Contact Number
Contact Diameter
Current Rating
Contact Resistance
Contact mating force
Contact Life Cycle
Breakdown Voltage Between Contacts
Dielectric Withstanding Voltage
Temperature Rating
Insulation Resistance
Insulator Material
Contact- Material- Plating (Mating surfaces)
Guide Hardware- Material- Plating
Plating Reference
17, 29, 33, 41, 48, 53, 62, 65, 72, 80, 84, 96, 98, 119, 120, 149 & 160
0,60 mm
4 A
7 Milli-Ohm (max)
0,28 N (average)
> 2000
1920 V AC (min) [sea level]
1400 V AC (min) [sea level]
-55 to +125 Degree C
5 Gigo-Ohm @ 500 V DC (min)
DAP
Copper alloy1,27 micro-metres Gold Plate (min)
Stainless steel BS 303Passivated
N/A
Technical Characteristics
![Page 2: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/2.jpg)
HPD Series
HPD connectors summary
38 APRIL 2005
![Page 3: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/3.jpg)
HPD Series
s
dedicated chapters
HPD connectors summary
39APRIL 2005
![Page 4: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/4.jpg)
HPD Series
SOLID INSULATOR
PREFIX
No. of CAVITIESD - 017*, 029*, 033*, 041*, 053*, 072π,
084*, 096*, 120π
P - 033*, 041*, 053*, 065*, 096*, 120π,
F - 048*, 062*, 080*, 098*, 119*, 149*, 160*, 320π
M - 048*, 098π, 119π, 160*
CONTACT PLATINGU=
Gold Plate / Space Qualified Product (ASTM-B-488) S=Gold Plate (ASTM-B-488)
CONTACT GENDERM = MaleF = FemaleO = Contacts not suppliedC* = Pin Carrier - HPD & HPF only
CONTACT TERMINATIONStyles: A, B*, C*, D, F, G, L*, M, P*, Q, R, S, T, W, X*, Y, Z,
1, 2, 3, 4, 5, and 9 (See ʻHPD contact termination and codesʼ for details)
or 0* - Contacts not supplied
GUIDES STYLES(See ʻHPD guide style indexʼ and ʻ HPD guide stylesʼ for details) or 00=Guides not supplied
PRINTING0 = Reverse2 = Standard
5 = Reverse7 = Standard
8 = Reverse9 = Standard(See ʻHPD insulatorsʼ for details)
0 = No variations3 = Centre guide polarisedD = Outer 2 of 3 rows loadedQ = Centre row of 3 rows loaded
BS SpecStandard
MIL SpecStandard
(80 position cutfrom 160 position)
}}}
0 = No variationsB = 900 termination tinned and pottedC = 900 termination pottedX = Termination tinned2 = Strengthened insulator 84 and 96
position vertical mounting only
H D 0 4 1 U M B K 0 0 2 0P
* πOff the shelf Made to order
VARIATION CODES
Ordering Information
40 APRIL 2005
![Page 5: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/5.jpg)
HPD Series
EXAMPLE GUIDE STYLES KS (MALE POLARISED) IS REQUIRED
HPD06500KS00H = TWO (HPD KS) GUIDESor
HPD072000KS00H = TWO (HPD KS) GUIDES + ONE (HPD AS) UNPOLARISED GUIDE.or
HPF149000KS00H = TWO (HPF KS) GUIDESor
HPF160000KS00H = TWO (HPF KS) GUIDES + ONE (HPF AS) UNPOLARISED GUIDE
Two part insulator
PREFIX
No. of CAVITIES098, 160
CONTACT PLATINGA= Gold PlateU= Gold Plate (ASTM-B-488)
CONTACT GENDERF = Female
CONTACT TERMINATION6, 7, 8 (See ‘HPD contact termination and codes’ for details)
PRINTING0 = Reverse2 = Standard
5 = Reverse7 = Standard
(See ‘HPD insulators’ for details)
0 = No variations3 = Centre guide polarisedD = Outer 2 of 3 rows loadedQ = Centre row of 3 rows loaded
BS SpecStandard
MIL SpecStandard
}}
2 = Two part insulator
P
GUIDE STYLESL1, L2, L5, 5G, 5L, 5M, 5N(See ‘HPD guide style index’ and ‘HPD guide styles’ for details)
VARIATION CODES
If additional guides are required
PREFIX
D = HPD StyleF = HPF Style065 = Set of two HPD Guides072 = Set of three HPD Guides149 = Set of two HPF Guides160 = Set of three HPF Guides
GUIDE STYLES(See ‘HPD guide style index’ and ‘HPD guide styles’ for details)
P
Ordering Information
41APRIL 2005
![Page 6: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/6.jpg)
HPD Series
HPD insulators
42 APRIL 2005
Dimensions are in mm
![Page 7: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/7.jpg)
HPD insulators
HPD Series
43APRIL 2005
Dimensions are in mm
![Page 8: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/8.jpg)
HPD Series
44 APRIL 2005
Dimensions are in mm
HPD insulators
![Page 9: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/9.jpg)
HPD insulators
HPD Series
45APRIL 2005
Dimensions are in mm
![Page 10: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/10.jpg)
HPD Series
46 APRIL 2005
Dimensions are in mm
HPD insulators
![Page 11: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/11.jpg)
HPD insulators
HPD Series
47APRIL 2005
Dimensions are in mm
![Page 12: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/12.jpg)
HPD Series
48 APRIL 2005
Dimensions are in mm
HPD insulators
![Page 13: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/13.jpg)
HPD insulators
HPD Series
49APRIL 2005
Dimensions are in mm
![Page 14: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/14.jpg)
HPD Series
50 APRIL 2005
HPD insulators polarising data
![Page 15: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/15.jpg)
HPD insulators
Panel preparation details
HPD Series
51APRIL 2005
Dimensions are in mm
Board preparation details
![Page 16: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/16.jpg)
HPD Series
52 APRIL 2005
Dimensions are in mm
HPD insulators board preparation details
![Page 17: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/17.jpg)
HPD insulators board preparation details
HPD Series
53APRIL 2005
Dimensions are in mm
![Page 18: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/18.jpg)
HPD Series
54 APRIL 2005
Dimensions are in mm
HPD contact termination and codes
![Page 19: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/19.jpg)
HPD / HPF Guide torque information
HPD/HPF torque valuesStainless Steel Guide
HPD Series
55APRIL 2005
![Page 20: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/20.jpg)
HPD Series
56 APRIL 2005
HPD intermatability charts
Jack guide - Polarised and unpolarised
![Page 21: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/21.jpg)
HPD intermatability charts
Polarised guides intermatability chart
HPD Series
57APRIL 2005
![Page 22: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/22.jpg)
HPD Series
58 APRIL 2005
HPD intermatability charts
Unpolarised guides intermatability chart
Quarter turn lockpolarised guides intermatability chart
![Page 23: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/23.jpg)
Hypertac s
HPD guide style
HPD Series
59APRIL 2005
Dimensions are in mm
![Page 24: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/24.jpg)
HPD Series
60 APRIL 2005
Dimensions are in mm
HPD guide style
Jack guides (male) - Unpolarised
![Page 25: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/25.jpg)
HPD guide style
Guides (male) - Polarised
HPD Series
61APRIL 2005
Dimensions are in mm
![Page 26: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/26.jpg)
HPD Series
62 APRIL 2005
Dimensions are in mm
HPD guide style
Guides (male) - Unpolarised
![Page 27: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/27.jpg)
HPD guide style
Jack guides (female) - Unpolarised
HPD Series
63APRIL 2005
Dimensions are in mm
![Page 28: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/28.jpg)
HPD guide style
Guides (female) - Unpolarised
Guides (female) quarter turn lock-polarised
HPD Series
64 APRIL 2005
Dimensions are in mm
![Page 29: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/29.jpg)
HPD Series
65APRIL 2005
Dimensions are in mm
HPD accessories
![Page 30: ASTASTHPD Series 2 & 3 Contact Row Signal · PDF file2 & 3 Contact Row Signal Connectors ... • Large number of termination options ... The following shrouded sizes are qualified](https://reader034.vdocument.in/reader034/viewer/2022051600/5aa5cf837f8b9a7c1a8de84f/html5/thumbnails/30.jpg)
HPD Series
HPD accessories
66 APRIL 2005
Dimensions are in mm