automotive ethernet consortium - unh … · automotive. ethernet consortium . clause 96 ....

34
AUTOMOTIVE ETHERNET CONSORTIUM Clause 96 100BASE-T1 Physical Medium Attachment Test Suite Version 1.0 Technical Document Last Updated: March 9, 2016 Automotive Ethernet Consortium 21 Madbury Rd, Suite 100 Durham, NH 03824 University of New Hampshire Phone: (603) 862-0090 InterOperability Laboratory Fax: (603) 862-4181 http://www.iol.unh.edu/testing/ethernet/ae

Upload: vandien

Post on 29-May-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

AUTOMOTIVE ETHERNET CONSORTIUM

Clause 96

100BASE-T1 Physical Medium Attachment Test Suite Version 1.0

Technical Document

Last Updated: March 9, 2016

Automotive Ethernet Consortium 21 Madbury Rd, Suite 100 Durham, NH 03824 University of New Hampshire Phone: (603) 862-0090 InterOperability Laboratory Fax: (603) 862-4181 http://www.iol.unh.edu/testing/ethernet/ae

Page 2: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

TABLE OF CONTENTS MODIFICATION RECORD ................................................................................................................ 3

ACKNOWLEDGEMENTS................................................................................................................... 4

INTRODUCTION ................................................................................................................................. 5

DEVICE UNDER TEST (DUT) REQUIREMENTS............................................................................ 7

GROUP 1: Electrical Measurements .................................................................................................... 8

Test 96.1.1 – Maximum Transmitter Output Droop .............................................................................. 9

Test 96.1.2 – Transmitter Distortion................................................................................................... 11

Test 96.1.3 – Transmitter Timing Jitter .............................................................................................. 13

Test 96.1.4 – Transmitter Power Spectral Density .............................................................................. 15

Test 96.1.5 – Transmit Clock Frequency ............................................................................................ 16

Test 96.1.6 – MDI Return Loss .......................................................................................................... 17

Test 96.1.7 – MDI Mode Conversion Loss ......................................................................................... 18

GROUP 2: PMA Receive Tests ........................................................................................................... 19

Test 96.2.1 – Bit Error Rate Verification ............................................................................................ 20

Test 96.2.2 – Receiver Frequency Tolerance ...................................................................................... 21

Test 96.2.3 – Alien Crosstalk Noise Rejection ................................................................................... 22

TEST SUITE APPENDICES .............................................................................................................. 24

Appendix 96.A – 100BASE-T1 Transmitter Test Fixtures.................................................................. 25

Appendix 96.B – 100BASE-T1 Cabling for Receiver Testing ............................................................ 33

Automotive Ethernet Consortium 2 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 3: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

MODIFICATION RECORD

• March 9, 2016 (Version 1.0) Initial Release

Automotive Ethernet Consortium 3 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 4: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

ACKNOWLEDGEMENTS The University of New Hampshire would like to acknowledge the efforts of the following individuals in the development of this test suite. Curtis Donahue University of New Hampshire Stephen Johnson University of New Hampshire

Automotive Ethernet Consortium 4 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 5: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

INTRODUCTION The University of New Hampshire’s InterOperability Laboratory (IOL) is an institution designed to improve the interoperability of standards based products by providing an environment where a product can be tested against other implementations of a standard. This particular suite of tests has been developed to help implementers evaluate the functionality of the PMA sublayer of their 100BASE-T1 products.

These tests are designed to determine if a product conforms to specifications defined in the IEEE 802.3bw 100BASE-T1 Standard. Successful completion of all tests contained in this suite does not guarantee that the tested device will operate with other devices. However, combined with satisfactory operation in the IOL’s interoperability test bed, these tests provide a reasonable level of confidence that the Device Under Test (DUT) will function properly in many 100BASE-T1 automotive environments.

The tests contained in this document are organized in such a manner as to simplify the identification of information related to a test, and to facilitate in the actual testing process. Tests are organized into groups, primarily in order to reduce setup time in the lab environment, however the different groups typically also tend to focus on specific aspects of device functionality. A three-part numbering system is used to organize the tests, where the first number indicates the section of the IEEE 100BASE-T1 Standard on which the test suite is based. The second and third numbers indicate the test’s group number and test number within that group, respectively. This format allows for the addition of future tests to the appropriate groups without requiring the renumbering of the subsequent tests.

The test definitions themselves are intended to provide a high-level description of the motivation, resources, procedures, and methodologies pertinent to each test. Specifically, each test description consists of the following sections:

Purpose

The purpose is a brief statement outlining what the test attempts to achieve. The test is written at the functional level.

References

This section specifies source material external to the test suite, including specific subsections pertinent to the test definition, or any other references that might be helpful in understanding the test methodology and/or test results. External sources are always referenced by number when mentioned in the test description. Any other references not specified by number are stated with respect to the test suite document itself.

Resource Requirements

The requirements section specifies the test hardware and/or software needed to perform the test. This is generally expressed in terms of minimum requirements, however in some cases specific equipment manufacturer/model information may be provided.

Last Modification

This specifies the date of the last modification to this test.

Automotive Ethernet Consortium 5 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 6: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Discussion

The discussion covers the assumptions made in the design or implementation of the test, as well as known limitations. Other items specific to the test are covered here.

Test Setup

The setup section describes the initial configuration of the test environment. Small changes in the configuration should not be included here, and are generally covered in the test procedure section, below.

Test Procedure

The procedure section of the test description contains the systematic instructions for carrying out the test. It provides a cookbook approach to testing, and may be interspersed with observable results.

Observable Results

This section lists the specific observables that can be examined by the tester in order to verify that the DUT is operating properly. When multiple values for an observable are possible, this section provides a short discussion on how to interpret them. The determination of a pass or fail outcome for a particular test is generally based on the successful (or unsuccessful) detection of a specific observable.

Possible Problems

This section contains a description of known issues with the test procedure, which may affect test results in certain situations. It may also refer the reader to test suite appendices and/or whitepapers that may provide more detail regarding these issues.

Automotive Ethernet Consortium 6 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 7: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

DEVICE UNDER TEST (DUT) REQUIREMENTS For the purposes of this test suite, the DUT is one port of a 100BASE-T1 capable device that includes a 100BASE-T1 PHY mounted on a PCB with an MDI connector and any necessary circuitry such as a low pass filter or common mode choke. All tests will be performed at the MDI connector of the DUT.

Please see the additional requirements listed in the following table:

Test Number and Name Required Capabilities Group 1: Electrical Measurements Test 96.1.1 – Maximum Transmitter Output Droop Test Mode 1 Test 96.1.2 – Transmitter Distortion Test Mode 4 Test 96.1.3 – Transmitter Timing Jitter

Case 1: MASTER Test Mode 2 Case 2: SLAVE TX_TCLK access

Test 96.1.4 – Transmitter Power Spectral Density Test Mode 5 Test 96.1.5 – Transmit Clock Frequency Test Mode 2 Test 96.1.6 – MDI Return Loss Active Transmitter Test 96.1.7 – MDI Mode Conversion Loss Active Transmitter Group 2: PHY Control State Diagram Test 96.2.1 – Bit Error Rate Verification The ability to send and receive frames1 Test 96.2.2 – Receiver Frequency Tolerance The ability to send and receive frames1 Test 96.2.3 – Alien Crosstalk Noise Rejection The ability to send and receive frames1

1 This can be accomplished through a loopback, responding to ICMP requests, or by forwarding traffic through two ports

Automotive Ethernet Consortium 7 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 8: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

GROUP 1: Electrical Measurements Overview:

The tests defined in this section verify the electrical specifications of the 100BASE-T1 Physical Medium Attachment sublayer outlined in Clause 96 of the IEEE 802.3bw standard.

Automotive Ethernet Consortium 8 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 9: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.1 – Maximum Transmitter Output Droop Purpose: To verify that the transmitter output level does not droop more than the maximum specified amount. References:

[1] IEEE Std. 802.3bw, subclause 96.5.2 - Test modes [2] Ibid., subclause 96.5.3 - Test Fixtures [3] Ibid., subclause 96.5.4.1 - Transmitter Output Droop [4] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements:

• DSO • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω coaxial cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion:

Reference [1] states that a 100BASE-T1 device shall implement 5 test modes. These test modes are provided to measure electrical characteristics and verify compliance. Reference [2] defines the test fixture to be used to perform the test. Reference [1] defines the operation of a device while in test mode 1, and reference [3] provides a specification for the maximum allowable droop for the transmitter.

This test requires the DUT to operate in transmitter test mode 1. While in test mode 1, the DUT shall generate a sequence of at least 40 +1 symbols followed by at least 40 -1 symbols continually transmitted.

Droop is calculated after measuring the peak voltage (Vpk) and the voltage 500 ns after the peak (Vdelay). The difference Vd = Vpk - Vdelay. Droop = Vd/Vpk * 100%. This is performed on both the positive and negative peaks of the waveform transmitted by test mode 1. The magnitude of the droop should be less than 45.0%.

Test Setup: Refer to test suite appendix 96.A.3 Procedure:

1. Configure the DUT so that it is operating in transmitter test mode 1. 2. Connect BI_DA from the MDI to Test Fixture 1. 3. Find the rising-edge initial peak voltage (Vpk) in the waveform. 4. Measure the amplitude of the waveform at 500 ns after the initial peak (Vdelay) to find the droop

voltage (Vd). 5. Compute the droop between Vpk and Vd. 6. For enhanced accuracy, repeat steps 3-5 multiple times and average the results. 7. Repeat steps 1 through 6 using a falling edge reference.

Automotive Ethernet Consortium 9 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 10: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Observable Results:

a. The magnitude of the positive droop shall be less than 45.0%. b. The magnitude of the negative droop shall be less than 45.0%.

Possible Problems: None.

Automotive Ethernet Consortium 10 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 11: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.2 – Transmitter Distortion Purpose: To verify that the distortion of the transmitter is within the conformance limits. References:

[1] IEEE Std. 802.3bw, subclause 96.5.2 - Test modes [2] Ibid., subclause 96.5.3 - Test Fixtures [3] Ibid., subclause 96.5.4.2 - Transmitter Distortion [4] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements: • DSO • High Impedance Differential Probe • Short Automotive Cable • Transmitter Distortion Adapter

Last Modification: March 9, 2016 (version 1.0) Discussion:

Reference [1] states that a 100BASE-T1 device shall implement 5 test modes. These test modes are provided to measure electrical characteristics and verify compliance. Reference [2] defines the test fixture to be used to perform the test, as well as the disturbing signal characteristics (see [4] for more details). Reference [1] defines the operation of a device while in test mode 4, and reference [3] provides a specification for the maximum allowable distortion for the transmitter.

In this test, the peak distortion is measured by capturing the test mode 4 waveform and finding the least mean squared error. The peak error between the ideal reference and the observed symbols is the peak transmitter distortion. Reference [3] provides Matlab code for determining the peak distortion, note this code assumes the disturber signal and the data acquisition clock of the oscilloscope are frequency locked to the DUT TX_TCLK.

Test Setup: Refer to appendix 96.A.4 Procedure:

1. Configure the DUT so that it is sourcing the transmitter test mode 4 waveform. 2. Configure the disturber source as described in [2]. 3. Connect BI_DA from the MDI to Test Fixture 2. 4. Capture 2ms of consecutive symbols in the test mode 4 waveform. 5. Using the code provided in [3], process the 2ms capture in Matlab to calculate the peak distortion

at 10 uniformly spaced phase offsets over 1 UI. Observable Results:

a. The peak transmitter distortion should be less than 15mV for all of the sampled phase offsets over 1 UI.

Possible Problems: a. If the vertical resolution of the oscilloscope is less than 10 bits, then a low pass filter must be used

during post-processing. The Matlab code provided in [3] includes such a LPF.

Automotive Ethernet Consortium 11 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 12: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

b. If the TX_TCLK of the DUT is not accessible or the DUT does not have an external clock input, the test equipment will not be able to synchronize internal sampling clocks. Because of this, phase offsets will occur in test equipment and measured distortion values will not be as accurate than if the DUT’s TX_TCLK was available.

Automotive Ethernet Consortium 12 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 13: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.3 – Transmitter Timing Jitter Purpose: To verify that the transmitter timing jitter of the PMA is within the conformance limits. References:

[1] IEEE Std. 802.3bw, subclause 96.5.2 - Test modes [2] Ibid., subclause 96.5.3 - Test Fixtures [3] Ibid., subclause 96.5.4.3 - Transmit timing jitter [4] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements: • DSO • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω Coaxial Cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion:

Reference [1] states that a 100BASE-T1 device shall implement 5 test modes. These test modes are provided to measure electrical characteristics and verify compliance. Reference [2] defines the test fixture to be used to perform the test. Reference [3] provides a specification for the maximum allowable timing jitter for the transmitter.

Case 1 – MASTER transmitter timing jitter

When in test mode 2, the PHY transmits +1 symbols followed by -1 symbols continuously. In this mode, the transmitter output should be a 331

3 MHz signal and the RMS TIE jitter measured at the

PHY MDI output shall be less than 50 ps. The RMS period jitter is measured over an integration time interval of at least 1 ms.

Case 2 – SLAVE transmitter timing jitter (if applicable) SLAVE transmitter timing jitter can only be performed when the DUTs TX_TCLK is exposed and accessible. For normal operation as the SLAVE, the DUTs reference clock is recovered from a compliant LP PHY operating as MASTER. The RMS TIE jitter of the SLAVE TX_TCLK shall not exceed 0.01 UI (150 ps).

Test Setup: Refer to test suite appendix 96.A.3 Procedure: Case 1 – MASTER transmitter timing jitter

1. Configure the DUT so that it is operating in transmitter test mode 2. 2. Connect BI_DA from the MDI to Test Fixture 1. 3. Capture at least 1ms and process the capture to determine the RMS TIE jitter. 4. For enhanced accuracy, repeat step 3 multiple times.

Automotive Ethernet Consortium 13 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 14: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Case 2 – SLAVE transmitter timing jitter 1. Configure the DUT so that it is operating in normal mode, forced to SLAVE. 2. Configure the LP so that it is operating in normal mode, forced to MASTER. 3. Connect the DUT TX_TCLK to channel 2 of the DSO. 4. Capture at least 1ms and process the capture with a PC to determine the RMS TIE jitter. 5. For enhanced accuracy, repeat step 4 multiple times.

Observable Results: Case 1 – MASTER transmitter timing jitter

a. The RMS TIE jitter measured at the MDI output should not exceed 50 ps.

Case 2 – SLAVE transmitter timing jitter (if applicable) a. The RMS TIE jitter of the SLAVE TX_TCLK should not exceed 0.01 UI (150 ps).

Possible Problems: If the DUT does not provide access to the TX_TCLK, SLAVE jitter (case 2) testing cannot be performed.

Automotive Ethernet Consortium 14 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 15: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.4 – Transmitter Power Spectral Density Purpose: To verify the transmitter power spectral density are within the conformance limits. References:

[1] IEEE Std. 802.3bw, subclause 96.5.2 - Test modes [2] Ibid., subclause 96.5.3 - Test Fixtures [3] Ibid., section 96.5.4.4 - Transmitter Power Spectral Density (PSD) [4] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements:

• SA or DSO with spectral measurement capabilities • Balun • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω coaxial cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion: Reference [1] states that a 100BASE-T1 device shall implement 5 test modes. These test modes are provided to measure electrical characteristics and verify compliance. Reference [2] defines the test fixture to be used to perform the test. Reference [1] defines the operation of a device while in test mode 5, and reference [3] provides the transmitter PSD mask. Test Setup: Refer to test suite appendix 96.A.5 Procedure:

1. Configure the DUT so that it is operating in transmitter test mode 5. 2. Connect BI_DA from the MDI to Test Fixture 3. 3. Capture the spectrum of the transmitted test mode waveform using a SA (or DSO). 4. For enhanced accuracy, repeat step 3 multiple times and average the power measured at each

point. 5. Compute the transmitter PSD.

Observable Results:

a. The PSD of the transmitter output while operating in test mode 5 shall fit within the transmitter PSD mask defined in [3].

Possible Problems: None.

Automotive Ethernet Consortium 15 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 16: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.5 – Transmit Clock Frequency Purpose: To verify that the frequency of the Transmit Clock is within the conformance limits References:

[1] IEEE Std. 802.3bw, section 96.5.4.5 - Transmit Clock Frequency [2] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements:

• DSO • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω coaxial cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion:

Reference [1] states that all 100BASE-T1 devices must have a symbol transmission rate of 6623

MHz ± 100ppm while operating in MASTER timing mode. This corresponds to a transmit clock of 66.6603 MHz to 66.6736 MHz.

The reference clock used in this test is the one obtained in test 5.1.3, Transmitter Timing Jitter - Case 1. The frequency of this clock, extracted from the transmitted test mode 2 waveform, shall have a base frequency of 662

3 MHz ± 100ppm.

Test Setup: Refer to test suite appendix 96.A.3 Procedure:

1. Configure the DUT for test mode 2 operation. 2. Connect BI_DA from the MDI to Test Fixture 1. 3. Using a narrow-bandwidth PLL, extract the clock frequency from the transmitted symbols. 4. For enhanced accuracy, repeat step 2 multiple times. 5. Measure the frequency of the transmit clock.

Observable Results:

a. The transmit clock generated by the DUT shall have a frequency between 66.6603MHz and 66.6736MHz.

Possible Problems: None.

Automotive Ethernet Consortium 16 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 17: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.6 – MDI Return Loss Purpose: To measure the return loss at the MDI. References:

[1] IEEE Std. 802.3bw, subclause 96.8.2.1 – MDI Return Loss [2] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements:

• VNA or TDR with frequency domain capabilities • Balun • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω coaxial Cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion:

A compliant 100BASE-T1 device shall ideally have a differential characteristic impedance of 100Ω. This is necessary to match the characteristic impedance of the automotive cabling. Any difference between these impedances will result in a partial reflection of the transmitted signals. Return loss is a measure of the signal power that is reflected due to the impedance mismatch. Reference [1] specifies the conformance limits for the reflected power measured at the MDI. The specification states that the return loss must be maintained transmitting data or control symbols.

Test Setup: Refer to test suite appendix 96.A.6 Procedure:

1. Configure the DUT for test mode 5 operation. 2. Calibrate the VNA (or TDR) to remove the effects of the test jig and connecting cable. 3. Connect the BI_DA from the MDI to the reflection port of the network analyzer. 4. Measure the reflections at the MDI referenced to a 100Ω characteristic impedance.

Observable Results:

a. The return loss measured at the MDI shall be at least 20 dB from 1 to 30MHz, and at least 20-20*log10(f/30) dB from 30 to 66MHz when referenced to a characteristic impedance of 100Ω.

Possible Problems: None.

Automotive Ethernet Consortium 17 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 18: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.1.7 – MDI Mode Conversion Loss Purpose: To measure the mode converison loss at the MDI. References:

[1] IEEE Std. 802.3bw, subclause 96.8.2.2 – MDI Mode Conversion Loss [2] Test suite appendix 96.A – 100BASE-T1 Transmitter Test Fixtures

Resource Requirements:

• VNA or TDR with frequency domain capabilities • Balun • 2-pin to SMA Adapter • Short Automotive Cable • 50Ω coaxial Cables, matched length

Last Modification: March 9, 2016 (version 1.0) Discussion:

A compliant 100BASE-T1 device shall ideally have a differential characteristic impedance of 100Ω, however mismatches in the positive and negative polarities of the MDI output will introduce mode conversion. Reference [1] specifies the conformance limits for the mode conversion measured at the MDI. Test Setup: Refer to test suite appendix 96.A.6 Procedure:

1. Configure the DUT for test mode 5 operation. 2. Calibrate the VNA (or TDR) to remove the effects of the test jig and connecting cable. 3. Connect the BI_DA from the MDI to the reflection port of the network analyzer. 4. Measure the mode conversion loss at the MDI referenced to a 100Ω characteristic impedance.

Observable Results:

a. The mode conversion loss measured at the MDI shall be at least 50 dB from 1 to 33MHz, and at least 50-20*log10(f/33) dB from 33 to 200MHz when referenced to a characteristic impedance of 100Ω.

Possible Problems: None.

Automotive Ethernet Consortium 18 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 19: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

GROUP 2: PMA Receive Tests Overview:

This section verifies the integrity of the 100BASE-T1 PMA Receiver through frame reception tests.

Automotive Ethernet Consortium 19 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 20: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.2.1 – Bit Error Rate Verification Purpose: To verify that the DUT can maintain a BER of less than 10-10. References:

[1] IEEE Std. 802.3bw, subclause 96.5.5.1 - Receiver Differential Input Signals [2] Ibid., subclause 96.7 – Link Segment Characteristics [3] IOL TP-PMD Test Suite Appendix 25.D [4] Test suite appendix 96.B – 100BASE-T1 Cabling for Receiver Testing

Resource Requirements:

• Packet transmit/monitoring station • Automotive cables of varying lengths

Last Modification: March 9, 2016 (version 1.0) Discussion: Reference [1] states that a 100BASE-T1 capable PHY shall not exceed a BER of less than 10-10. The cables used for receiver BER testing are automotive cables, conformant to the characteristics described in [2] but representative of a worst case channel. Channel characteristics of the worst case channel are further discussed in [4]. Packet transmit and monitoring stations are used to verify the BER of the DUT.

Based on the analysis given in reference [3], if more than 7 errors are observed in 3x1010

bits

(about 2,470,000 1,518-byte packets), it can be concluded that the error rate is greater than 10-10

with less than a 5% chance of error. Note that if no errors are observed, it can be concluded that the BER is no

more than 10-10

with less than a 5% chance of error.

Test Setup: Refer to test suite appendix 96.A.7 Procedure:

1. Configure the DUT as MASTER. 2. Connect the packet monitoring station to the automotive cable. 3. Connect the DUT to the automotive cable. 4. Send 2,470,000 1,518-byte packets (for a 10-10 BER) and the monitor will count the number of

packet errors. 5. Repeat step 4 for the remaining automotive cables. 6. Repeat steps 4-5 with the DUT configured as SLAVE.

Observable Results:

a. The DUT shall maintain a BER of less than 10-10 for all automotive cable lengths. Possible Problems: None.

Automotive Ethernet Consortium 20 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 21: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.2.2 – Receiver Frequency Tolerance Purpose: To verify that the DUT can properly accept incoming data with the symbol rate of 66 2

3 MHz

+/- 100 ppm. References:

[1] IEEE Std. 802.3bw, subclause 96.5.5.2 - Receiver Frequency Tolerance [2] Ibid., subclause 96.7 – Link Segment Characteristics [3] Test suite appendix 96.B – 100BASE-T1 Cabling for Receiver Testing

Resource Requirements:

• Packet transmit/monitoring station capable of a configurable transmit clock • Automotive cable representative of worst case channel

Last Modification: March 9, 2016 (version 1.0) Discussion: Reference [1] states that a 100BASE-T1 capable PHY shall properly accept incoming data with the symbol rate of 66 2

3 MHz +/- 100 ppm. This corresponds to a transmit clock of 66.6603MHz to

66.6736 MHz. Please refer to Test 96.2.1 – Bit Error Rate Verification, of this document, for further details regarding the worst case channel and packet analysis. The cables used for receiver frequency tolerance testing are automotive cables, conformant to the characteristics described in [2] but representative of a worst case channel. Channel characteristics of the worst case channel are further described in [3]. Test Setup: Refer to test suite appendix 96.A.7 Procedure: Part A

1. Configure the DUT as SLAVE. 2. Connect the packet transmit/monitoring station to the automotive cable. 3. Connect the DUT to the automotive cable. 4. Configure the packet transmit/monitoring station to transmit data with a clock of 66.6603 MHz. 5. Send 2,470,000 1,518-byte packets (for a 10-10 BER) and monitor the number of packet errors. 6. Repeat step 3-5 using a transmit clock of 66.6736 MHz.

Observable Results:

a. The DUT shall maintain a BER of less than 10-10 when recovering a transmit clock of 66.6603 MHz or 66.6736 MHz for all automotive cable lengths.

Possible Problems: None.

Automotive Ethernet Consortium 21 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 22: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Test 96.2.3 – Alien Crosstalk Noise Rejection Purpose: To verify that the DUT can maintain a bit error rate of less than 10-10 in the presence of a noise

source. References:

[1] IEEE Std. 802.3bw, subclause 96.5.5.3 – Alien Crosstalk Noise Rejection [2] Ibid., subclause 96.7 – Link Segment Characteristics [3] Test suite appendix 96.B – 100BASE-T1 Cabling for Receiver Testing

Resource Requirements: • Packet transmit/monitoring station • Worst case automotive crosstalk noise injection cable • 100BASE-T1 100 Mbps idle symbol noise source • Gaussian signal generator

Last Modification: March 9, 2016 (version 1.0) Discussion: Reference [1] defines a test cable which uses a resistive network to inject crosstalk noise into the receive path of the DUT. Reference [1] goes on to state that a 100BASE-T1 capable PHY shall not exceed a BER of less than 10-10, even with alien crosstalk noise present. The cables used for receiver frequency tolerance testing are automotive cables, conformant to the characteristics described in [2] but representative of a worst case channel. Channel characteristics of the worst case channel are further discussed in [3]. Test Setup: Refer to test suite appendix 96.A.8 Procedure:

1. Configure the DUT as MASTER. 2. Connect the packet transmit/monitoring station to the worst case automotive crosstalk noise

injection cable. 3. Connect the DUT to the worst case automotive crosstalk noise injection cable. 4. Send 2,470,000 1,518-byte packets (for a 10-10 BER) and the monitor will count the number of

packet errors. 5. Repeat step 4 with the DUT configured as SLAVE. 6. Repeat steps 1 through 5 using a Gaussian signal generator as the noise source.

Observable Results:

a. The DUT shall maintain a BER of less than 10-10 when using the worst case automotive crosstalk noise injection cable with a compliant 100BASE-T1 transmitter as the noise source.

b. The DUT shall maintain a BER of less than 10-10 when using the worst case automotive crosstalk noise injection cable with a Gaussian signal generator as the noise source.

Possible Problems: None.

Automotive Ethernet Consortium 22 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 23: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Automotive Ethernet Consortium 23 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 24: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

TEST SUITE APPENDICES Overview:

The appendices contained in this section are intended to provide additional low-level technical details pertinent to specific tests defined in this test suite. Test suite appendices often cover topics that are beyond the scope of the standard, but are specific to the methodologies used for performing the measurements covered in this test suite. This may also include details regarding a specific interpretation of the standard (for the purposes of this test suite), in cases where a specification may appear unclear or otherwise open to multiple interpretations. Scope: Test suite appendices are considered informative, and pertain only to tests contained in this test suite.

Automotive Ethernet Consortium 24 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 25: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Appendix 96.A – 100BASE-T1 Transmitter Test Fixtures Purpose: To provide a reference implementation of Test Fixtures 1 through 3 as well as other transmit

and receive test setups. References:

[1] IEEE Std. 802.3bw, subclause 96.5.3 - Test fixtures [2] Ibid., subclause 96.7 – Link Segment characteristics [3] Ibid., subclause 96.8 – MDI specification [4] Ibid., subclause 96.5.5.3 – Alien Crosstalk Noise Rejection

[5] IOL TP-PMA Test Suite Appendix 40.B [6] Test suite appendix 96.B – 100BASE-T1 Cabling for Receiver Testing

Resource Requirements: • DSO: Capable of 1 GHz DSO bandwidth and a sampling rate of 2 GS/s or higher. • SA: Capable of operating up to 200 MHz with a dynamic range of 50 dBm or higher, or

equivalent Digital oscilloscope with spectral measurement capabilities. • VNA: Capable of measuring up to 100 MHz, or equivalent TDR with frequency domain

capabilities • Packet transmit/monitoring system • 2-pin to SMA Adapter • Transmitter distortion Adapter • High Impedance Differential Probe: Capable of operating up to 1 GHz or higher. • Balun: Capable of operating up to 200 MHz or higher. • Disturbing signal generator: Capable of producing a sinusoid with differential amplitude of

5.4 Vpp and a frequency of 11.111 MHz • Automotive cabling: Various lengths • 50Ω coaxial cables, matched length • Worst case automotive crosstalk noise injection cable • 100BASE-T1 Idle Symbol Noise Source • Gaussian signal generator

Last Modification: March 9, 2016 (version 1.0) Discussion: 96.A.1- Introduction Reference [1] defines three test fixtures to be used in the verification of 100BASE-T1 transmitter specifications. The purpose of this appendix is to present a reference implementation of these test fixtures. This appendix describes test setups that can be used as Test Fixtures 1 through 3, a setup for Return Loss, and Group 2: PMA Receive Test measurements. 96.A.2 – Cabling and Adapters

Reference [2] states that 1 is designed to operate over 100Ω one pair cable (automotive cable), and [3] defines the MDI connector can be any connector currently used in the automotive industry that does not degrade a signal worse than a 15 meter 100Ω one pair cable. Leaving the choice of cabling and

Automotive Ethernet Consortium 25 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 26: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

MDI connector up to the DUT manufacturer; because of this, flexibility is required in the development of the test setups. An SMA adapter board accompanied by a short automotive cable will be used to connect the DUT to test equipment. Figure A.1 illustrates the SMA adapter.

Figure A.1: 2-pin to SMA Adapter

Due to the wide variety of connectors that could be tested, a single cable cannot be used to

connect every DUT to the SMA adapter. A Short automotive cable with a connector that can mate with the DUT MDI on one end and can connect to the two pins on the SMA adapter, described above, on the other end will be used. By doing this a different cable can be used for each DUT and allow calibrating out the loss of the cable and adapter so that the test point will be at the devices MDI.

Figure A.2: Transmitter Distortion Adapter

A second adapter was developed for measuring transmitter distortion, illustrated in Figure A.2. To measure distortion an additional probing point is needed so that the disturbing sine wave can be delivered to the DUT, as well as measure the sum of the test mode 4 pattern and the disturbed voltage with a high impedance differential probe. This adapter is incorporated into the Test Fixture 3 test setup described in Figure A.5.

Top View

Side View

Angled View

Top View

Side View

Angled View

Automotive Ethernet Consortium 26 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 27: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

96.A.3 – Test Fixture 1 Test Fixture 1 described in [1] will be used for maximum transmitter output droop and transmitter timing jitter (when the DUT is in MASTER mode). Figure A.3 shows a diagram of the Test Fixture 1 setup.

Figure A.3: Droop, Jitter (Master) Test Setup (Test Fixture 1)

The DUT is connected to the short automotive cable and 2-pin to SMA adapter described in

96.A.2, then connected to the DSO using matched length SMA cables. The test mode waveforms are downloaded to a pc where Matlab scripts post-process the data.

When testing SLAVE jitter Test Fixture 1 must be modified to include the use of a 100BASE-T1

link partner. The DUT is forced to link in SLAVE mode and the MDI is connected to the MDI of the LP (which is forced to link in MASTER mode) using a short automotive cable. The TX_TCLK of the DUT is then connected to the DSO. See Figure A.4 for this setup. If the TX_TCLK of the DUT is not accessible SLAVE jitter cannot be performed.

Automotive Ethernet Consortium 27 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 28: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Figure A.4: Jitter (SLAVE) Test Setup

96.A.4 – Test Fixture 2 In Test Fixture 2, the DUT is directly connected to a 100Ω differential voltage generator. The voltage generator transmits a sine wave of specific frequency and amplitude; which is referred to as the disturbing signal, Vd. An oscilloscope monitors the output of the DUT through a high impedance differential probe. The disturbing sine wave characteristics are given in Table A-1.

Table A-1: Characteristics of disturber waveform Vd Amplitude Vd Frequency

5.4 V peak-to-peak 11.111 MHz

The purpose of Vd is to simulate the presence of a remote transmitter. If the DUT is not

sufficiently linear, the disturbing signal will cause significant distortion products to appear in the DUT output. Note that while the oscilloscope sees the sum of the Vd and the DUT output, only the DUT output is of interest. Therefore post-processing is required to remove the disturbing signal from the measurement.

Upon looking at the Test Fixture 3 definition shown in [1], it is important to note that Vd is

defined as the voltage before the 50Ω resistors. Thus, the amount of voltage seen at the transmitter under test is 50% of the original amplitude of Vd.

Automotive Ethernet Consortium 28 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 29: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Figure A.5: Distortion Test Setup (Test Fixture 2)

The IEEE802.3bw standard requires the test equipment used for transmit distortion measurements

be synchronized with the DUT’s TX_TCLK, this guarantees that the internal sampling clock of each piece of equipment shares a common clock source and is phase locked. How to generate a reference clock from the TX_TCLK is not defined but can be achieved in several ways. Using a frequency divider to generate a 10 MHz clock from the 662

3 MHz TX_CLK is one such technique. This is depicted in Figure

A.4 with a dashed line. However, depending on the DUT’s design and form factor the TX_TCLK may not be exposed or brought out to a probe-able pin. When the TX_TCLK is not accessible distortion testing will need to be tested without test equipment synchronization. Because of this phase offsets will occur between the clock sources of each test equipment, and measured distortion values will most likely be worse than if the DUT’s TX_TCLK was available.

A Matlab script is provided in the IEEE802.3bw standard to calculate transmitter distortion.

Embedded within the script are hardware requirements for the oscilloscope used to capture the test mode 4 pattern. The requirements include a sample rate of 2GS/s and an ADC vertical resolution of 8 bits or more. It also goes on to state that if the ADC resolution is less than 10 bits then the data is to be processed through an optional section of code that includes a 331

3 MHz low pass filter. However since the

oscilloscope sample rate and ADC resolution are not discussed outside the Matlab code it makes the implementation of the optional code subjective and left to the interpretation of the tester. Additionally, ADC vertical resolution settings available to the user will differ from equipment vendor to equipment vendor. There are DSOs in the market that offer >8 bit native ADC vertical resolution but most DSOs have a native ADC vertical resolution of 8 bits. Depending on the DSO the ADC resolution may be increased above the native settings, this is achieved by applying DSP techniques. The exact details of the DSP used to increase the ADC resolution is proprietary and is up to the equipment vendor to divulge.

Automotive Ethernet Consortium 29 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 30: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Since the DSP techniques used to increase the ADC resolution are not fully available to the user it is possible that the unspecified filtering can artificially lower distortion values. Measured distortion values will vary significantly based on the ADC settings, care should be taken when choosing ADC settings. For testing performed at the IOL, equipment will be chosen so that when testing transmitter distortion the sample rate will be exactly 2GS/s and the Matlab low pass filter will only be used if the native ADC resolution is less than 10 bits. 96.A.5 – Test Fixture 3 Test Fixture 3 described in [1] will be used for transmitter PSD measurements. The PSD profile is downloaded from the SA and post-processed in Matlab. Figure A.6 shows a diagram of the Test Fixture 3 setup. A balun is necessary to convert the differential transmission of the DUT to a single-ended input for the SA.

Figure A.6: PSD Test Setup (Test Fixture 3)

96.A.6 – MDI Return Loss and Mode Conversion Loss Setup The MDI return loss and mode conversion loss measurements are performed with a VNA. Depending on the design of the VNA there may only be a single input port, if this is the case a balun will need to be used to convert the differential transmission of the DUT to a single-ended input for the VNA. See figure A.7. However, if the VNA has two or more input ports a balun is not necessary, see Figure A.8.

Automotive Ethernet Consortium 30 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 31: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Figure A.7: Single Input VNA

Figure A.8: Two Input VNA

96.A.7 – PMA Receiver Testing Setup Figure A.9 describes the setup for Test 96.2.1 and 96.2.2, the only difference between the setups is the frequency of the link partner transmit clock (please see subclause 96.5.5.1 and 96.5.5.2 for each tests respective clock settings). A packet generation and monitoring station will be used to measure the amount of dropped packets. This test is performed over various automotive cable lengths, representative of the worst case channel defined in [2], to simulate real world environments. The channel characteristics regarding the worst case channel is discussed in [6].

Figure A.9: BER & Receiver Frequency Tolerance Test Setup

96.A.8 – Alien Crosstalk Noise Rejection Setup Figure A.10 describes the test cable used to introduce the crosstalk source defined in [4]. A small adapter populated with the necessary resistors is soldered to the end of an automotive cable, closest to the receiver under test. Since the MDI mechanical specification can vary between vendors an additional, very short, automotive cable is necessary to connect the DUT to the adapter. The insertion loss of the test cable, including the very short patch cable, is conformant to the worst case characteristics described in [2]. The channel characteristics regarding the worst case channel is discussed in [6].

Automotive Ethernet Consortium 31 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 32: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

*Link segments not drawn to scale

Figure A.10: Alien Crosstalk Noise Rejection Setup

Automotive Ethernet Consortium 32 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 33: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Appendix 96.B – 100BASE-T1 Cabling for Receiver Testing Purpose: To describe the characteristics of various automotive cables used to verify BER, Receiver

Frequency Tolerance, and Alien Crosstalk Noise Rejection. References:

[1] IEEE 802.3bw, subclause 96.7 – Link Segment characteristics Last Modification: March 10, 2016(version 1.0) Discussion: Reference [1] specifies the 100BASE-T1 cabling system by defining it as a differential 100Ω one pair cabling system up to 15 meters in length with inline connectors, and goes on to give specification limits for insertion loss, return loss, mode conversion loss, and alien crosstalk. While [1] does specify a maximum whole communication channel (WCC) segment length of 15 meters, component and cable quality used in the WCC will dictate the overall performance, meaning a WCC may be greater than 15 meters in length but still be conformant to the previously listed parameter limits. That being said, a “worst case” channel is ideally defined as a WCC with 4 inline connectors and channel characteristics that are as close to the parameter limit values as possible while still being in the conformant range. While a “worst case” WCC (WC-WCC) is ideally a channel that is close to violating the parameter limits but still conformant, it is nearly impossible to meet this criteria for all channel parameters. Instead, the WC-WCC is more specifically defined as a channel with 4 inline connectors that is tuned to nearly violate the insertion loss specifications while being conformant to the return loss limit. Figure B.1 shows the insertion loss limit defined in [1] in red, while all other curves represent channels that have losses equivalent to 10, 20, 30, 40, 50, 60, 70, 80, and 90 % of the WC-WCC.

Automotive Ethernet Consortium 33 Clause 96 – 100BASE-T1 PMA Test Suite v1.0

Page 34: AUTOMOTIVE ETHERNET CONSORTIUM - UNH … · AUTOMOTIVE. ETHERNET CONSORTIUM . Clause 96 . 100BASE-T1 Physical Medium Attachment Test Suite . Version 1.0 . Technical Document . Last

The University of New Hampshire InterOperability Laboratory

Figure B.1: Worst Case Whole Communication Channels

Testing over more than one WCC ensures that the DUT can not only communicate with a LP over channels with significant loss but also can communicate over shorter WCCs which are less lossy but usually have worse return loss characteristics.

Automotive Ethernet Consortium 34 Clause 96 – 100BASE-T1 PMA Test Suite v1.0