av plan notes - maine

3
NOTE 1 - GENERAL A. MOUNT ALL DEVICES AS RECOMMENDED BY THE MANUFACTURER. B. PROVIDE ALL REQUIRED MOUNTING HARDWARE, AND SECURE TO BLOCKING BY OTHERS. PAINT HARDWARE TO MATCH WALL OR CEILING. C. FOR ALL DEVICES EXPOSED TO VIEW, PAINT OR PROVIDE FACTORY FINISHES AS DIRECTED. D. MOUNT ALL DEVICES AT HEIGHT AND LOCATION DIRECTED. COORDINATE WITH OTHER TRADES. E. FOR ALL DEVICES MOUNTED ABOVE CEILINGS, COORDINATE LOCATIONS TO AVOID CONFLICT WITH OTHER DEVICES AND SYSTEMS. F. COORDINATE THE SEQUENCE OF THE WORK WITH THE CONSTRUCTION MANAGER AND WITH OTHER TRADES AT THE JOBSITE. NOTE 2 - WALL MOUNTED DEVICES A. IF NOT PROVIDED WITH INTEGRAL POST - CONSTRUCTION WALL MOUNT ENCLOSURE, MOUNT WITHIN JUNCTION BOX OR PLASTER RING AS PROVIDED BY OTHERS. COORDINATE WITH OTHER TRADES. B. INSTALL AT HEIGHT AND LOCATION DIRECTED. COORDINATE WITH OTHER SERVICES WHICH MAY ALREADY BE IN PLACE. NOTE 3 - CONNECTION PANELS A. WHERE SHOWN AT WALL, MOUNT WITHIN JUNCTION BOX OR PLASTER RING AS PROVIDED BY OTHERS. COORDINATE WITH OTHER TRADES. NOTE 4 - FLOOR BOXES A. COORDINATE WITH FLOOR BOX SUPPLIER SO THAT BOX IS SUPPLIED WITH BLANK FACEPLAGE OF SUFFICIENT SIZE TO ACCEPT AUDIO - VISUAL CONNECTIONS AS SHOWN ON FUNCTIONAL DIAGRAMS. B. 120V POWER SERVICES BY OTHERS. VOICE AND DATA COMMUNICATIONS SERVICES BY OTHERS. C. DO NOT ALLOW ANY AUDIO - VISUAL CABLING TO SHARE WIRING COMPARTMENT IN USE BY OTHER SERVICES. COORDINATE WITH OTHER TRADES. NOTE 5 - EQUIPMENT RACKS A. FIELD VERIFY PROPER FIT INTO LOCATION SHOWN BEFORE ORDERING RACK. COORDINATE WITH OTHER TRADES. B. DO NOT ENERGIZE UNTIL PROPER VENTILATION IS CONFIRMED. NOTE 6 - PLAYBACK EQUIPMENT CABINETS OR INSTRUCTOR'S STATIONS A. LOCATE WITHIN CREDENZA OR BASE CABINET BY OTHERS. FIELD VERIFY PROPER FIT BEFORE ORDERING. COORDINATE WITH MILLWORKER OR FURNITURE SUPPLIER. B. DO NOT ENERGIZE UNTIL PROPER VENTILATION IS CONFIRMED. NOTE 7 - TABLE TOP SERVICES MODULES A. COORDINATE WITH FURNITURE SUPPLIER SO THAT TABLE TOP SERVICES MODULE IS SUPPLIED WITH BLANK FACEPLATE OF SUFFICIENT SIZE TO ACCEPT AUDIO - VISUAL CONNECTIONS AS SHOWN ON FUNCTIONAL DIAGRAMS. B. WHERE SPECIFIED AS FURNISHED BY AUDIO - VISUAL CONTRACTOR, DELIVER TO OTHER TRADES FOR INSTALLATION BY OTHERS. C. 120V POWER SERVICES BY OTHERS. VOICE AND DATA COMMUNICATIONS SERVICES BY OTHERS. D. MOUNT POWER SUPPLIES, INTERFACES, AND OTHER ACCESSORY ITEMS CONCEALED BENEATH TABLE TOP OR WITHIN TABLE BASE. PROVIDE WIRE MANAGEMENT AS REQUIRED, EMPLOYING SCREW - ATTACHED (NOT ADHESIVE - BACKED) FASTENERS. DRESS ALL CABLING SO THAT NO CABLING IS VISIBLE BENEATH TABLE TOP. NOTE 8 - DOCKING STATIONS FOR WIRELESS DEVICES A. LOCATE DOCKING STATION WHERE DIRECTED. COORDINATE WITH FURNITURE OR CASEWORK SUPPLIER TO ENSURE ACCESS TO NECESSARY 120V POWER AND/OR DATA COMMUNICATIONS SERVICES. NOTE 9 - CAMERAS A. MOUNT CAMERA TO WALL OR CEILING EMPLOYING SPECIFIED MOUNT. PAINT MOUNT AND ALL HARDWARE TO MATCH WALL OR AS DIRECTED. B. WHERE VIDEO CONFERENCE CAMERA IS LOCATED AT FLAT PANEL DISPLAY, INSTALL CAMERA ON SHELF ABOVE OR BELOW FLAT PANEL AS DIRECTED, WITH MINIMAL SEPARATION BETWEEN CAMERA AND FLAT PANEL. NOTE 10 - FIXED TABLE MICROPHONES A. MOUNT SECURELY ON TOP OF WORK SURFACE, AND RUN CABLE HORIZONTALLY BENEATH WORK SURFACE. PROVIDE ALL REQUIRED CABLE MANAGEMENT TO THE EXTENT NOT PROVIDED BY OTHERS. SECURE CABLES WITH SCREW ATTACHED (NOT ADHESIVE) FASTENERS. B. COORDINATE WITH FURNITURE SUPPLIER SO THAT REQUIRED TABLE CUTOUT IS PROVIDED BY FURNITURE SUPPLIER. C. EMPLOY RIGHT - ANGLE CONNECTORS ON ANY THROUGH - TABLE MICROPHONES, AND TAKE OTHER MEASURES TO MINIMIZE EXTENT TO WHICH CABLING AND HARDWARE WILL BE VISIBLE BENEATH THE TABLE. NOTE 11 - CEILING LOUDSPEAKERS A. INSTALL IN CEILING AS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLAN. COORDINATE WITH OTHER CEILING - MOUNTED ELEMENTS. B. WHERE SHOWN IN ACOUSTICAL CEILING TILE, INSTALL WITH TILE BRIDGE OR OTHER MEANS TO PREVENT CEILING SAG. PROVIDE ALL REQUIRED MOUNTING HARDWARE AND ACCESSORIES. C. WHERE LOUDSPEAKER ENCLOSURES ARE PROVIDED BY OTHERS, PROVIDE LOUDSPEAKER AND BAFFLE AS REQUIRED TO ACHIEVE COMPLETE ASSEMBLY. D. PAINT OR PROVIDE FACTORY FINISH AS SELECTED BY ARCHITECT. NOTE 12 - MONITORS AND TELEVISIONS A. MOUNT FLAT PANEL DISPLAYS TO WALL OR CEILING USING SPECIFIED MOUNTS. ALIGN TO BE PLUMB AND LEVEL, AND TIGHTEN ADJUSTING HARDWARE. COORDINATE LOCATION OF ELECTRICAL AND LOW VOLTAGE SERVICES WITH OTHER TRADES. CONCEAL ALL CABLES. B. PROVIDE SHIMS OR BLOCKING AS REQUIRED SO THAT FACE OF DISPLAY IS FLUSH WITH SURROUNDING FINISHED WALL. C. FIELD VERIFY ADEQUATE BLOCKING AND ADEQUATE VENTILATION BEFORE BEGINNING INSTALLATION. D. COORDINATE LOCATION OF ELECTRICAL AND LOW - VOLTAGE SERVICES WITH MONITOR MOUNTING HARDWARE. WHERE REQUIRED, PROVIDE 120V LINE CORDS WITH RIGHT ANGLE PLUGS. E. LOCATE DISPLAY DRIVERS AND ACCESSORY DEVICES CONCEALED BEHIND DISPLAY EMPLOYING LOW - PROFILE MOUNTING HARDWARE AND RIGHT - ANGLE CONNECTORS. WHERE RECESSED JUNCTION BOX IS EMPLOYED, LOCATE DISPLAY DRIVERS AND ACCESSORY DEVICES CONCEALED WITHIN JUNCTION BOX. AV PLAN NOTES NOTE 13 - PROJECTORS A. MOUNT PROJECTOR TO ABOVE - CEILING STRUCTURAL SUPPORT FRAMEWORK OR TO CEILING - MOUNTED EQUIPMENT ENCLOSURE, FRAMEWORK OR ENCLOSURE AS PROVIDED BY OTHERS. COORDINATE LOCATION OF STRUCTURAL SUPPORTS AS REQUIRED TO ACHIEVE SPECIFIED PROJECTION GEOMETRY. B. PROVIDE ALL MOUNTING BRACKETS AND OTHER REQUIRED HARDWARE. PAINT ALL VISIBLE HARDWARE WHITE OR AS DIRECTED. CONCEAL ALL CABLING. C. WHERE USED WITH PROJECTION SCREEN, POSITION PROJECTOR AS REQUIRED TO FILL HEIGHT AND WIDTH OF SCREEN, WITH BOTTOM OF IMAGE AT 42" ABOVE FLOOR OR AS DIRECTED. POSITION WITHIN CENTER 50% OF LENS RANGE. LOCATE FOR CORRECT IMAGE GEOMETRY UNDER ALL CONDITIONS, WITH PROPER ASPECT RATIO, FREE OF KEYSTONE AND OTHER GEOMETRY ERROR. DO NOT EMPLOY ELECTRONIC KEYSTONE CORRECTION. NOTE 14 - ELECTRIC PROJECTION SCREENS A. ELECTRIC PROJECTION SCREEN, LOW VOLTAGE MOTOR CONTROLLER, AND LOW VOLTAGE CONTROL SWITCH ALL BY OTHERS. FIELD VERIFY SCREEN SIZE AND DROP. PROVIDE LOW VOLTAGE CONTROL CONNECTION TO AUDIO - VISUAL CONTROL SYSTEM AS SHOWN ON DRAWINGS. B. ADJUST PROJECTION SCREEN LIMIT SWITCH AS NECESSARY TO ACHIEVE REQUIRED PROJECTION GEOMETRY. NOTE 15 - PROJECTOR ELEVATORS A. DELIVER ELEVATOR TO GENERAL CONTRACTOR FOR INSTALLATION BY OTHER TRADES. COORDINATE AS REQUIRED. NOTE 16 - OWNER'S CABLING STANDARDS A. EMPLOY PLENUM - RATED CABLE FOR ALL CABLE INSTALLED ABOVE THE CEILING, WHETHER PLENUM SPACES OR NOT. AV SYMBOL KEY CEILING - MOUNTED DEVICE WALL - MOUNTED DEVICE FLOOR - MOUNTED DEVICE LP1 LP1 LP1 EQUIPMENT RACK WITHIN CREDENZA RK AUDIOVISUAL DEVICE LEGEND DEVICE PURPOSE OR EQUIPMENT SERVED NOTES CA1 PAN/TILT/ZOOM CAMERA, CEILING MOUNTED CA2 FIXED VIEW CAMERA, WALL MOUNTED CM CEILING MICROPHONE OR MICROPHONE ARRAY E3 CONNECTION TO PLAYBACK EQUIPMENT FB1 FLOOR POKETHROUGH FC FIXED VIEW CAMERA, CEILING MOUNTED FP FLAT PANEL LARGE FS FLAT PANEL SMALL HTH PORTABLE TELE-HEALTH SYSTEM M1 WALL MOUNTED MICROPHONE S1 CEILING LOUDSPEAKER TP WALL TELEPHONE WITH AUDIO TAP TPM TOUCH SCREEN CONTROL PANEL AV SHEET LIST Sheet Number Sheet Name AV000 AUDIOVISUAL NOTES AND SCHEDULES AV400 AUDIOVISUAL PLANS - LEVEL FOUR AV401 AUDIOVISUAL SYSTEMS - ELEVATIONS AND SECTIONS Architect of Record Ellenzweig 230 Congress Street Boston MA 02110 T 617 491-5575 F 617 868-2318 MEP | FA | FP Allied Engineering 106 Veranda Street Portland, ME, 04103 T 207 221-2260 F 207 221-2266 Notes: Job Number Drawing By Checked By Date Revisions SD / 50% DD Scale: Keyplan 2019 Ellenzweig © Audio-Visual Cavanaugh Tocci 327 F Boston Post Road Sudbury, MA, 01776 T 978 443-7871 12" = 1' - 0" C:\REVIT LOCAL\19132 - USM Nursing Sim Lab\31905_USM_AV_R19_jmm.rvt 10/16/2019 3:27:41 PM UNIVERSITY OF SOUTHERN MAINE 96 Falmouth Street Portland, ME 04103 31905 JMM NB 10.18.2019 AUDIOVISUAL NOTES AND SCHEDULES AV000 HIGH FIDELITY NURSING SIMULATION LAB No. Date Description

Upload: others

Post on 01-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AV PLAN NOTES - Maine

NOTE 1 - GENERAL

A. MOUNT ALL DEVICES AS RECOMMENDED BY THE MANUFACTURER. B. PROVIDE ALL REQUIRED MOUNTING HARDWARE, AND SECURE TO

BLOCKING BY OTHERS. PAINT HARDWARE TO MATCH WALL OR CEILING.

C. FOR ALL DEVICES EXPOSED TO VIEW, PAINT OR PROVIDE FACTORY FINISHES AS DIRECTED.

D. MOUNT ALL DEVICES AT HEIGHT AND LOCATION DIRECTED. COORDINATE WITH OTHER TRADES.

E. FOR ALL DEVICES MOUNTED ABOVE CEILINGS, COORDINATE LOCATIONS TO AVOID CONFLICT WITH OTHER DEVICES AND SYSTEMS.

F. COORDINATE THE SEQUENCE OF THE WORK WITH THE CONSTRUCTION MANAGER AND WITH OTHER TRADES AT THE JOBSITE.

NOTE 2 - WALL MOUNTED DEVICES

A. IF NOT PROVIDED WITH INTEGRAL POST-CONSTRUCTION WALL MOUNT ENCLOSURE, MOUNT WITHIN JUNCTION BOX OR PLASTER RING AS PROVIDED BY OTHERS. COORDINATE WITH OTHER TRADES.

B. INSTALL AT HEIGHT AND LOCATION DIRECTED. COORDINATE WITH OTHER SERVICES WHICH MAY ALREADY BE IN PLACE.

NOTE 3 - CONNECTION PANELS

A. WHERE SHOWN AT WALL, MOUNT WITHIN JUNCTION BOX OR PLASTER RING AS PROVIDED BY OTHERS. COORDINATE WITH OTHER TRADES.

NOTE 4 - FLOOR BOXES A. COORDINATE WITH FLOOR BOX SUPPLIER SO THAT BOX IS SUPPLIED

WITH BLANK FACEPLAGE OF SUFFICIENT SIZE TO ACCEPT AUDIO-VISUAL CONNECTIONS AS SHOWN ON FUNCTIONAL DIAGRAMS.

B. 120V POWER SERVICES BY OTHERS. VOICE AND DATA COMMUNICATIONS SERVICES BY OTHERS.

C. DO NOT ALLOW ANY AUDIO-VISUAL CABLING TO SHARE WIRING COMPARTMENT IN USE BY OTHER SERVICES. COORDINATE WITH OTHER TRADES.

NOTE 5 - EQUIPMENT RACKS

A. FIELD VERIFY PROPER FIT INTO LOCATION SHOWN BEFORE ORDERING RACK. COORDINATE WITH OTHER TRADES.

B. DO NOT ENERGIZE UNTIL PROPER VENTILATION IS CONFIRMED. NOTE 6 - PLAYBACK EQUIPMENT CABINETS OR INSTRUCTOR'S STATIONS

A. LOCATE WITHIN CREDENZA OR BASE CABINET BY OTHERS. FIELD

VERIFY PROPER FIT BEFORE ORDERING. COORDINATE WITH MILLWORKER OR FURNITURE SUPPLIER.

B. DO NOT ENERGIZE UNTIL PROPER VENTILATION IS CONFIRMED.

NOTE 7 - TABLE TOP SERVICES MODULES

A. COORDINATE WITH FURNITURE SUPPLIER SO THAT TABLE TOP SERVICES MODULE IS SUPPLIED WITH BLANK FACEPLATE OF SUFFICIENT SIZE TO ACCEPT AUDIO-VISUAL CONNECTIONS AS SHOWN ON FUNCTIONAL DIAGRAMS.

B. WHERE SPECIFIED AS FURNISHED BY AUDIO-VISUAL CONTRACTOR, DELIVER TO OTHER TRADES FOR INSTALLATION BY OTHERS.

C. 120V POWER SERVICES BY OTHERS. VOICE AND DATA COMMUNICATIONS SERVICES BY OTHERS.

D. MOUNT POWER SUPPLIES, INTERFACES, AND OTHER ACCESSORY ITEMS CONCEALED BENEATH TABLE TOP OR WITHIN TABLE BASE. PROVIDE WIRE MANAGEMENT AS REQUIRED, EMPLOYING SCREW-ATTACHED (NOT ADHESIVE-BACKED) FASTENERS. DRESS ALL CABLING SO THAT NO CABLING IS VISIBLE BENEATH TABLE TOP.

NOTE 8 - DOCKING STATIONS FOR WIRELESS DEVICES

A. LOCATE DOCKING STATION WHERE DIRECTED. COORDINATE WITH

FURNITURE OR CASEWORK SUPPLIER TO ENSURE ACCESS TO NECESSARY 120V POWER AND/OR DATA COMMUNICATIONS SERVICES.

NOTE 9 - CAMERAS

A. MOUNT CAMERA TO WALL OR CEILING EMPLOYING SPECIFIED MOUNT.

PAINT MOUNT AND ALL HARDWARE TO MATCH WALL OR AS DIRECTED. B. WHERE VIDEO CONFERENCE CAMERA IS LOCATED AT FLAT PANEL

DISPLAY, INSTALL CAMERA ON SHELF ABOVE OR BELOW FLAT PANEL AS DIRECTED, WITH MINIMAL SEPARATION BETWEEN CAMERA AND FLAT PANEL.

NOTE 10 - FIXED TABLE MICROPHONES

A. MOUNT SECURELY ON TOP OF WORK SURFACE, AND RUN CABLE

HORIZONTALLY BENEATH WORK SURFACE. PROVIDE ALL REQUIRED CABLE MANAGEMENT TO THE EXTENT NOT PROVIDED BY OTHERS. SECURE CABLES WITH SCREW ATTACHED (NOT ADHESIVE) FASTENERS.

B. COORDINATE WITH FURNITURE SUPPLIER SO THAT REQUIRED TABLE CUTOUT IS PROVIDED BY FURNITURE SUPPLIER.

C. EMPLOY RIGHT-ANGLE CONNECTORS ON ANY THROUGH-TABLE MICROPHONES, AND TAKE OTHER MEASURES TO MINIMIZE EXTENT TO WHICH CABLING AND HARDWARE WILL BE VISIBLE BENEATH THE TABLE.

NOTE 11 - CEILING LOUDSPEAKERS

A. INSTALL IN CEILING AS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLAN. COORDINATE WITH OTHER CEILING-MOUNTED ELEMENTS.

B. WHERE SHOWN IN ACOUSTICAL CEILING TILE, INSTALL WITH TILE BRIDGE OR OTHER MEANS TO PREVENT CEILING SAG. PROVIDE ALL REQUIRED MOUNTING HARDWARE AND ACCESSORIES.

C. WHERE LOUDSPEAKER ENCLOSURES ARE PROVIDED BY OTHERS, PROVIDE LOUDSPEAKER AND BAFFLE AS REQUIRED TO ACHIEVE COMPLETE ASSEMBLY.

D. PAINT OR PROVIDE FACTORY FINISH AS SELECTED BY ARCHITECT.

NOTE 12 - MONITORS AND TELEVISIONS

A. MOUNT FLAT PANEL DISPLAYS TO WALL OR CEILING USING SPECIFIED MOUNTS. ALIGN TO BE PLUMB AND LEVEL, AND TIGHTEN ADJUSTING HARDWARE. COORDINATE LOCATION OF ELECTRICAL AND LOW VOLTAGE SERVICES WITH OTHER TRADES. CONCEAL ALL CABLES.

B. PROVIDE SHIMS OR BLOCKING AS REQUIRED SO THAT FACE OF

DISPLAY IS FLUSH WITH SURROUNDING FINISHED WALL. C. FIELD VERIFY ADEQUATE BLOCKING AND ADEQUATE VENTILATION

BEFORE BEGINNING INSTALLATION.D. COORDINATE LOCATION OF ELECTRICAL AND LOW-VOLTAGE

SERVICES WITH MONITOR MOUNTING HARDWARE. WHERE REQUIRED, PROVIDE 120V LINE CORDS WITH RIGHT ANGLE PLUGS.

E. LOCATE DISPLAY DRIVERS AND ACCESSORY DEVICES CONCEALED BEHIND DISPLAY EMPLOYING LOW-PROFILE MOUNTING HARDWARE AND RIGHT-ANGLE CONNECTORS. WHERE RECESSED JUNCTION BOX IS EMPLOYED, LOCATE DISPLAY DRIVERS AND ACCESSORY DEVICES CONCEALED WITHIN JUNCTION BOX.

AV PLAN NOTES

NOTE 13 - PROJECTORS

A. MOUNT PROJECTOR TO ABOVE-CEILING STRUCTURAL SUPPORT FRAMEWORK OR TO CEILING-MOUNTED EQUIPMENT ENCLOSURE, FRAMEWORK OR ENCLOSURE AS PROVIDED BY OTHERS. COORDINATE LOCATION OF STRUCTURAL SUPPORTS AS REQUIRED TO ACHIEVE SPECIFIED PROJECTION GEOMETRY.

B. PROVIDE ALL MOUNTING BRACKETS AND OTHER REQUIRED HARDWARE. PAINT ALL VISIBLE HARDWARE WHITE OR AS DIRECTED. CONCEAL ALL CABLING.

C. WHERE USED WITH PROJECTION SCREEN, POSITION PROJECTOR AS REQUIRED TO FILL HEIGHT AND WIDTH OF SCREEN, WITH BOTTOM OF IMAGE AT 42" ABOVE FLOOR OR AS DIRECTED. POSITION WITHIN CENTER 50% OF LENS RANGE. LOCATE FOR CORRECT IMAGE GEOMETRY UNDER ALL CONDITIONS, WITH PROPER ASPECT RATIO, FREE OF KEYSTONE AND OTHER GEOMETRY ERROR. DO NOT EMPLOY ELECTRONIC KEYSTONE CORRECTION.

NOTE 14 - ELECTRIC PROJECTION SCREENS

A. ELECTRIC PROJECTION SCREEN, LOW VOLTAGE MOTOR CONTROLLER, AND LOW VOLTAGE CONTROL SWITCH ALL BY OTHERS. FIELD VERIFY SCREEN SIZE AND DROP. PROVIDE LOW VOLTAGE CONTROL CONNECTION TO AUDIO-VISUAL CONTROL SYSTEM AS SHOWN ON DRAWINGS.

B. ADJUST PROJECTION SCREEN LIMIT SWITCH AS NECESSARY TO ACHIEVE REQUIRED PROJECTION GEOMETRY.

NOTE 15 - PROJECTOR ELEVATORS

A. DELIVER ELEVATOR TO GENERAL CONTRACTOR FOR INSTALLATION BY

OTHER TRADES. COORDINATE AS REQUIRED.

NOTE 16 - OWNER'S CABLING STANDARDS

A. EMPLOY PLENUM-RATED CABLE FOR ALL CABLE INSTALLED ABOVE THE CEILING, WHETHER PLENUM SPACES OR NOT.

AV SYMBOL KEY

CEILING-MOUNTED DEVICE

WALL-MOUNTED DEVICE

FLOOR-MOUNTED DEVICE

LP1

LP1

LP1

EQUIPMENT RACK WITHIN CREDENZARK

AUDIOVISUAL DEVICE LEGEND

DEVICE PURPOSE OR EQUIPMENT SERVED NOTES

CA1 PAN/TILT/ZOOM CAMERA, CEILING MOUNTED

CA2 FIXED VIEW CAMERA, WALL MOUNTED

CM CEILING MICROPHONE OR MICROPHONE ARRAY

E3 CONNECTION TO PLAYBACK EQUIPMENT

FB1 FLOOR POKETHROUGH

FC FIXED VIEW CAMERA, CEILING MOUNTED

FP FLAT PANEL LARGE

FS FLAT PANEL SMALL

HTH PORTABLE TELE-HEALTH SYSTEM

M1 WALL MOUNTED MICROPHONE

S1 CEILING LOUDSPEAKER

TP WALL TELEPHONE WITH AUDIO TAP

TPM TOUCH SCREEN CONTROL PANEL

AV SHEET LIST

Sheet Number Sheet Name

AV000 AUDIOVISUAL NOTES AND SCHEDULES

AV400 AUDIOVISUAL PLANS - LEVEL FOUR

AV401 AUDIOVISUAL SYSTEMS - ELEVATIONS AND SECTIONS

Architect of Record

Ellenzweig

230 Congress StreetBoston MA 02110

T 617 491-5575

F 617 868-2318

MEP | FA | FP

Allied Engineering

106 Veranda Street

Portland, ME, 04103

T 207 221-2260

F 207 221-2266

Notes:

Job Number

Drawing By

Checked By

Date

Revisions

SD / 50% DDScale:

Keyplan

2019 Ellenzweig ©

Audio-Visual

Cavanaugh Tocci

327 F Boston Post Road

Sudbury, MA, 01776

T 978 443-7871

12" = 1'-0"

C:\R

EV

IT L

OC

AL

\191

32

- U

SM

Nu

rsin

g S

im L

ab\3

19

05

_U

SM

_A

V_

R1

9_

jmm

.rvt

10

/16/2

01

9 3

:27

:41

PM

UNIVERSITY OFSOUTHERN MAINE96 Falmouth StreetPortland, ME 04103

31905

JMM

NB

10.18.2019

AUDIOVISUAL NOTES ANDSCHEDULES

AV000

HIGH FIDELITYNURSINGSIMULATION LAB

No. Date Description

Page 2: AV PLAN NOTES - Maine

G

F

E.9

13

3.6

3.644.1

SIM ROOM 1101

CONTROL ROOM102

SIM ROOM 2103

STORAGE104

OFFICE105

DE-BREIF 1106

AV4014

1

3

2

AV40112

9

11

10

AV4018

5

7

6

AV401

13

AV401

14

DE-BREIF 2115

DIGITAL SIGNAGE DISPLAY

VITALS MONITORS VITALS MONITORMANNEQUIN COMPUTERS

SIMULATION COMPUTER

A/V OPERATING CONTROLS

TP

TP

MULTI-VIEW MONITOR ANDA/V EQUIPMENT RACK BENEATH

M1

M1

M1

TPMTPM

CA2CA2

CA2CA2

FIXED CAMERA FOR RECORDING(TYP. EACH ROOM)

FIXED CAMERA FOR RECORDING(TYP. EACH ROOM)

AV OPERATING CONTROLS(TYP. EACH ROOM)

AV CONNECTIONFLUSH IN TABLE(TYP. EACH ROOM)

SIMULATION COMPUTERBENEATH TABLE(TYP. EACH ROOM)

FP- 75"FP- 75"

LCD MONITOR WITH VIDEO CONFERENCE SOUNDBAR BELOW (TYP. EACH ROOM)

AV

RACK

AV EQUIPMENT RACK WITHIN CREDENZA(TYP. EACH ROOM)

AV

RACK

AV401

15

HTH

HTH

FP- 40"

MICROPHONE FOR RECORDING AND VIDEOCONFERENCING (TYP. EACH ROOM)

FB1FB1

G

F

E.9

E

122.233.644.1

SIM ROOM 1101

CONTROL ROOM102

SIM ROOM 2103

STORAGE104

OFFICE105

DE-BREIF 1106 DE-BREIF 2

115

FC CM

CA1

CMFC CA1

S1

S1

CA1 S1

S1

CA1

S1

CM FC

S1

CA1

CA1

CA1

CM

MAIN CORRIDOR116

Architect of Record

Ellenzweig

230 Congress StreetBoston MA 02110

T 617 491-5575

F 617 868-2318

MEP | FA | FP

Allied Engineering

106 Veranda Street

Portland, ME, 04103

T 207 221-2260

F 207 221-2266

Notes:

Job Number

Drawing By

Checked By

Date

Revisions

SD / 50% DDScale:

Keyplan

2019 Ellenzweig ©

Audio-Visual

Cavanaugh Tocci

327 F Boston Post Road

Sudbury, MA, 01776

T 978 443-7871

As indicated

C:\U

sers

\nb\D

ocum

ents

\31905_U

SM

_A

V_R

19_nbro

wse@

cavto

cci.com

.rvt

11/4

/2019 5

:22:1

4 P

M

UNIVERSITY OFSOUTHERN MAINE96 Falmouth StreetPortland, ME 04103

31905

JMM

NB

10.18.2019

AUDIOVISUAL PLANS -LEVEL FOUR

AV400

HIGH FIDELITYNURSINGSIMULATION LAB

1/4" = 1'-0"1

AUDIOVISUAL PLAN - LEVEL 4

1/4" = 1'-0"3

AUDIOVISUAL REFLECTING CEILING PLAN - LEVEL 04

No. Date Description

Page 3: AV PLAN NOTES - Maine

VITALS MONITOR

VITALS MONITOR

CONNECTION TO PORTABLE TELE-HEALTH SYSTEM

WALL TELEPHONE WITH AUDIO TAP

VITALS MONITOR(TYPICAL)

WALL MOUNTED MICROPHONE(TYPICAL)

HEADPHONE CONNECTION BENEATH (EACH SIDE)

MANNEQUIN AND SIMULATIONCOMPUTERS(TYP. EACH SIDE)

HEADPHONE CONNECTION BELOW COUNTER (EACH SIDE)

MULTI-VIEW MONITOR(TYP. EACH SIDE)

EQUIPMENT RACK BENEATH(TYP. EACH SIDE)

HEADPHONE CONNECTION BELOW COUNTER(TYP. 3 EACH COUNTER)

MANNEQUIN COMPUTER

SIMULATION COMPUTER

MULTI-VIEW MONITOR ON THE COUNTER

EQUIPMENT RACK BENEATH

MANNEQUIN COMPUTERS

SIMULATION COMPUTER

A/V OPERATING CONTROLS

MULTI-VIEW MONITOR

HEADPHONE CONNECTION BELOW COUNTER(TYP. 3 EACH COUNTER)

EQUIPMENT RACKBENEATH

WALL TELEPHONE WITH AUDIO TAP

CONNECTION TO PORTABLE TELE-HEALTH SYSTEM

VITALS MONITOR

VITALS MONITOR

WALL MOUNTED MICROPHONE

42"

LCD MONITOR WITH VIDEO CONFERENCESOUNDBAR BELOW

FIXED CAMERA FOR RECORDING

A/V OPERATING CONTROLS

A/V EQUIPMENT RACK

42"

LCD MONITOR WITH VIDEO CONFERENCESOUNDBAR BELOW

FIXED CAMERA FOR RECORDING

A/V OPERATING CONTROLS

A/V EQUIPMENT RACK

DIGITAL SIGNAGE

5'-6

"

Architect of Record

Ellenzweig

230 Congress StreetBoston MA 02110

T 617 491-5575

F 617 868-2318

MEP | FA | FP

Allied Engineering

106 Veranda Street

Portland, ME, 04103

T 207 221-2260

F 207 221-2266

Notes:

Job Number

Drawing By

Checked By

Date

Revisions

SD / 50% DDScale:

Keyplan

2019 Ellenzweig ©

Audio-Visual

Cavanaugh Tocci

327 F Boston Post Road

Sudbury, MA, 01776

T 978 443-7871

1/4" = 1'-0"

C:\R

EV

IT L

OC

AL

\191

32

- U

SM

Nu

rsin

g S

im L

ab\3

19

05

_U

SM

_A

V_

R1

9_

jmm

.rvt

10

/16/2

01

9 3

:27

:57

PM

UNIVERSITY OFSOUTHERN MAINE96 Falmouth StreetPortland, ME 04103

31905

JMM

NB

10.18.2019

AUDIOVISUAL SYSTEMS -ELEVATIONS ANDSECTIONS

AV401

HIGH FIDELITYNURSINGSIMULATION LAB

1/4" = 1'-0"1

NORTH ELEVATION - SIM ROOM 1

1/4" = 1'-0"2

SOUTH ELEVATION - SIM ROOM 1

1/4" = 1'-0"3

EAST ELEVATION - SIM ROOM 1

1/4" = 1'-0"4

WEST ELEVATION - SIM ROOM 1

1/4" = 1'-0"9

NORTH ELEVATION - CONTROL ROOM

1/4" = 1'-0"10

SOUTH ELEVATION - CONTROL ROOM

1/4" = 1'-0"11

EAST ELEVATION - CONTROL ROOM

1/4" = 1'-0"12

WEST ELEVATION - CONTROL ROOM

1/4" = 1'-0"5

NORTH ELEVATION - SIM ROOM 2

1/4" = 1'-0"6

SOUTH ELEVATION - SIM ROOM 2

1/4" = 1'-0"7

EAST ELEVATION - SIM ROOM 2

1/4" = 1'-0"8

WEST ELEVATION - SIM ROOM 2

1/4" = 1'-0"13

SOUTH ELEVATION - DE-BRIEF ROOM 106

1/4" = 1'-0"14

SOUTH ELEVATION - DE-BRIEF ROOM 115

1/4" = 1'-0"15

SOUTH ELEVATION - DIGITAL SIGNAGE

No. Date Description