BC162 RANGE Voltages 120V - 600V Outputs from 12.5 - 31.3 kVA FEATURES: Advanced automatic voltage regulator (AVR) control for trouble-free operation under the most demanding conditions 2/3 pitch winding as standard, to avoid excessive neutral currents Single or two bearing construction with dynamically balanced rotor and sealed-for-life bearings Easy access for installation and maintenance IP23 as standard product profile OPTIONS & ACCESSORIES: Anti Condensation Heaters Air Filters RFI Suppression to EC Standards SX465 AVRs for Parallel Operation Quadrature Droop kit for Parallel Operation SA465 AVR with 1% Regulation and 2 Phase Sensing SX421 AVR with improved Regulation 0.5% and 3 Phase Sensing (supplied loose) BC-162 9/30/03 11:57 AM Page 1

Upload: rahmat-nur-ilham

Post on 08-Apr-2016

5 views

Category:

Documents


0 download

DESCRIPTION

Generator Stamford BC-162

TRANSCRIPT

Page 1: bc-162

BC162 RANGEVoltages 120V - 600V

Outputs from 12.5 - 31.3 kVA

F E A T U R E S :

• Advanced automatic voltage regulator (AVR) control for trouble-free operation under the most demanding conditions

• 2/3 pitch winding as standard, to avoid excessive neutral currents

• Single or two bearing construction with dynamically balanced rotor and

sealed-for-life bearings

• Easy access for installation and maintenance

• IP23 as standard

product prof i le

O P T I O N S & A C C E S S O R I E S :• Anti Condensation Heaters

• Air Filters

• RFI Suppression to EC Standards

• SX465 AVRs for Parallel Operation

• Quadrature Droop kit for Parallel Operation

• SA465 AVR with 1% Regulation and 2 Phase Sensing

• SX421 AVR with improved Regulation 0.5% and 3 Phase Sensing (supplied loose)

BC-162 9/30/03 11:57 AM Page 1

Page 2: bc-162

BC162 RANGEproduct prof i le

T Y P I C A L A P P L I C AT I O N S :

Combined Heat & Power

Parallel Operation

Base Load Prime

Rental

Telecommunication

3 Phase Ratings for STAMFORD BC Generators

50Hz (3000 rpm) 60Hz (3600 rpm)

Rating/AmbientApplication/Temp Rise

VoltagePower Factor

BC 162D kVAkW

BC 162E kVAkW

BC 162F kVAkW

BC 162G kVAkW

Base 40ºCContinuous 125ºC

380 - 415V0.8

12.510.015.012.017.514.025.020.0

Base 40ºCContinuous 125ºC

416V0.8

14.711.817.814.220.816.629.623.7

440 - 480V0.8

15.612.518.815.021.917.531.325.0

1 Phase Ratings for STAMFORD BC Generators

50Hz (3000 rpm)

Winding 12 Wire Reconnectable60Hz (3600 rpm)

Rating/AmbientApplication/Temp Rise

Voltage

BC 162D kVAkW

BC 162E kVAkW

BC 162F kVAkW

BC 162G kVAkW

Base 40ºCContinuous 125ºC

220 - 240V

Base 40ºCContinuous 125ºC

240V

50Hz (3000 rpm)

4 Wire Dedicated60Hz (3600 rpm)

Base 40ºCContinuous 125ºC

220 - 240V

Base 40ºCContinuous 125ºC

240VPF 17.57.59.09.010.510.515.015.0

PF 0.87.56.09.07.2

10.58.4

15.012.0

PF 18.88.8

10.710.712.512.517.817.8

PF 0.88.87.0

10.78.6

12.510.017.814.2

PF 19.69.6

11.511.513.513.517.517.5

PF 0.88.46.7

10.08.0

11.89.4

16.813.4

PF 112.012.015.015.017.517.522.022.0

PF 0.810.08.0

12.49.9

14.411.520.616.5

NEWAGE International Limited PO Box 17 · Barnack Road · Stamford Lincolnshire · PE9 2NB · EnglandTel.: +44 (0) 17 80 48 40 00 · Fax: + 44 (0) 17 80 48 41 00 e-mail: [email protected] · internet: www.newage-avkseg.com

©Newage International 2002

Due t

o ou

r poli

cy o

f con

tinuo

us im

prov

emen

t, de

tails

in th

is lea

flet w

hich

were

corre

ct at

time

of p

rintin

gma

y no

w be

due

for a

mend

ment

. Inf

orma

tion

includ

ed m

ust t

here

fore

not

be r

egar

ded

as b

inding

PM_B

C162

PP

GB_1

1.02

_03_

GB

Standard Winding (311)

BC-162 9/30/03 11:57 AM Page 2