bl1

2
Signal Fitness-For-Service Report Input Data Assessment Information: Assessment Type: Laminations Design Code: ASME Section VIII Div 1 FFS Code: June 2007 API 579-1/ASME FFS-1 Units: lbs - in - psi Analysis By: SASSI Ali Project Information: Equipment Inputs: Equipment: Pressure Vessel Nominal Thickness: 0,551 in Inside Radius: 20,7675 in Length: 0 in Circumferential Weld Joint Factor: 0,85 Longitudinal Weld Joint Factor: 0,85 Material Properties: Material : ASME Section VIII Div 1 Design Temperature: 539,6 °F Operating Condition Inputs: Internal Uniform Metal Loss: 0 in External Uniform Metal Loss: 0 in Internal Future Corrosion Allowance: 0 in External Future Corrosion Allowance: 0 in Results Summary Section 13 Level 1 Satisfies June 2007 API 579-1/ASME FFS-1 Level 1 assessment. (Refer To: June 2007 API 579-1/ASME FFS-1 ) Section 13 Level 2 Satisfies June 2007 API 579-1/ASME FFS-1 Level 2 Assessment. (Refer To: June 2007 API 579-1/ASME FFS-1 ) Step By Step Results Section 13 Level 1 Satisfies June 2007 API 579-1/ASME FFS-1 Level 1 assessment. (Refer To: June 2007 API 579-1/ASME FFS-1 ) Analysis done according to June 2007 API 579-1/ASME FFS-1 Step 1: Determine if there is any bulging. Is Bulging = False Step 2: Determine the following parameters. s = 3,543 in c = 4,33 in L_h = 0,157 in L_s = 5,9 in t_mm = 0,268 in L_w = 50 in L_msd = 50 in Is Cracking = False Step 3: Check lamination spacing. L_s_critical = 1,102 in L_s >= L_s_critical ? Yes: 5,900 >= 1,102 Step 4: Check lamination height. L_h_critical = 0,390 in L_h <= L_h_critical ? Yes: 0,157 <= 0,390 Step 5: Determine the wall thickness to be used. Date: 09/06/2014 Generated By: Signal™ FitnessForService Professional Edition, Version 4.0.4283.23109 Signal FFS is written and maintained by Quest Integrity Group, a Team Industrial Services company Page 1 of 2

Upload: ali-sassi

Post on 18-Aug-2015

212 views

Category:

Documents


0 download

DESCRIPTION

BL1

TRANSCRIPT

Signal Fitness-For-Service ReportInput DataAssessment Information:Assessment Type: LaminationsDesign Code: ASME Section VIII Div 1FFS Code: June 2007 API 579-1/ASME FFS-1Units: lbs - in - psiAnalysis By: SASSI AliProject Information:Equipment Inputs:Equipment: Pressure VesselNominal Thickness: 0,551 inInside Radius: 20,7675 inLength: 0 inCircumferential Weld Joint Factor: 0,85Longitudinal Weld Joint Factor: 0,85Material Properties:Material : ASME Section VIII Div 1Design Temperature: 539,6FOperating Condition Inputs:Internal Uniform Metal Loss: 0 inExternal Uniform Metal Loss: 0 inInternal Future Corrosion Allowance: 0 inExternal Future Corrosion Allowance: 0 inResults SummarySection 13 Level 1Satisfies June 2007 API 579-1/ASME FFS-1 Level 1 assessment.(Refer To: June 2007 API 579-1/ASME FFS-1 )Section 13 Level 2Satisfies June 2007 API 579-1/ASME FFS-1 Level 2 Assessment.(Refer To: June 2007 API 579-1/ASME FFS-1 )Step By Step ResultsSection 13 Level 1Satisfies June 2007 API 579-1/ASME FFS-1 Level 1 assessment.(Refer To: June 2007 API 579-1/ASME FFS-1 )Analysis done according to June 2007 API 579-1/ASME FFS-1Step 1: Determine if there is any bulging.Is Bulging = FalseStep 2: Determine the following parameters.s = 3,543 inc = 4,33 inL_h = 0,157 inL_s = 5,9 int_mm = 0,268 inL_w = 50 inL_msd = 50 inIs Cracking = FalseStep 3: Check lamination spacing.L_s_critical = 1,102 inL_s >= L_s_critical ? Yes: 5,900 >= 1,102Step 4: Check lamination height.L_h_critical = 0,390 inL_h = 239,300The calculated MAWP is sufficient.Step 8: Return to service.The Level 1 assessment is complete and the component may be returned to service.Section 13 Level 2Satisfies June 2007 API 579-1/ASME FFS-1 Level 2 Assessment.(Refer To: June 2007 API 579-1/ASME FFS-1 )Analysis done according to June 2007 API 579-1/ASME FFS-1Step 1: Determine if there is any bulging.Is Bulging = FalseStep 2: Determine the following parameters.s = 3,543 inc = 4,33 inL_h = 0,157 inL_s = 5,9 int_mm = 0,268 inL_w = 50 inL_msd = 50 inIs Cracking = FalseStep 3: Check lamination spacing.L_s_critical = 1,102 inL_s >= L_s_critical ? Yes: 5,900 >= 1,102Step 4: Check lamination height.L_h_critical = 0,390 inL_h = 1,102L_msd >= allowable ? Yes: 50,000 >= 8,611Is Hydrogen Service = FalseStep 7: Check MAWP.MAWP_calculated = 332,980 psiMAWP_calc >= MAWP_design ? Yes: 332,980 >= 239,300The calculated MAWP is sufficient.FiguresDate: 09/06/2014Generated By:SignalFitnessForServiceProfessionalEdition,Version4.0.4283.23109Signal FFS is written and maintained by Quest Integrity Group, a Team Industrial Services companyPage 2 of 2