black gold vegetable oil heater
DESCRIPTION
Black Gold Vegetable Oil HeaterTRANSCRIPT
A COMPLETE PACKAGEEach EnergyLogic Boiler includes:
• SteadyFlo Fuel Pump System ..........................�Standard • Integrated Air Compressor ................................�Standard• Barometric Damper ..............................................�Standard • Draft Gauge ............................................................�Standard• AccuTemp Pre-Heater ..........................................�Standard • Hour Meter ..............................................................�Standard
SMALL FOOTPRINT
ASME CERTIFIEDVESSEL CONSTRUCTION• Heavy carbon-steel construction.• Stronger & more efficient than cast-iron boilers.• More corrosion resistant.• 80% efficiency rating.
• Saves space.• Makes installation simple.
REMOVABLE REAR ACCESS PANELRear panel access for easy,straight-thru cleaning.
WET FLOOR BASEDHEAT EXCHANGER• Heat exchanger is totally
water cooled.• Prevents hot spots and
metal deterioration.
Provides hot water for rest rooms,showers, dishwashers, etc.
DOMESTICHOT WATER COIL
INTEGRATEDAIR COMPRESSOR
Makes the heater a truly self-contained unit, not relying upon your shop air.
At EnergyLogic, a pioneer in waste-oil technology since 1984, we’re committed to value
and making products that combine only the highest quality, best performance, least amount
of maintenance and lowest cost of ownership for our customers. With a patent on every major component and an innovation on every
industry standard, our heaters and boilers outperform and outlast the competition. When you choose EnergyLogic, you’ll not only get
a product that operates as reliably as conventional heaters, but a product that requires minimal routine maintenance and is built to last.
FLAME RETENTION HEAD
Ensures a controlled flame andbetter combustion.
P
P
— Indicates Patented DesignP
Waste-Oil Boilers
P
P
• No manual adjustments required, regardless of viscosity.
• Ensures accurate fuel volume delivery.
STEADYFLO FUEL PUMP SYSTEM P
ACCUTEMP PRE-HEATER• The patented pre-heater heats
the oil before it enters the nozzle block, preventing residue build-up.
• The solid state technology allows for a more precise heating control which results in more efficient combustion.
CALL YOUR LOCAL DEALER FOR A LIST OF REFERENCES
AND SATISFIED CLIENTS
EL-200 B
Used-Oil Boiler Model 200 Used-Oil Boiler Model 500
COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil
FUEL METERING PUMP Precision metering over a wide range of fuels
UL CERTIFICATION UL listed system
FUEL FLOW RATE 1.4 gallons / 5.3 liters per hour
BTU INPUT 200,000 BTU / 58.3 kW per hour
WATER OUTPUT TEMPERATURE (MAX.) 230°F / 110°C
DOMESTIC HOT 4.0 gallons / 15 liters per minuteWATER OUTPUT at 100°F / 37.8°C temp rise
HEAT EXCHANGER Wet floor based design
BOILER CAPACITY 30 gallons / 113.56 liters
SYSTEM DIMENSIONS 45”H x 32”W x 50”D / 114cm H x 82cm W x 127 cm D
HOUR METER Analog (Clocks only actual burn time)
EXHAUST FLUE DIAMETER 8” / 20.32 cm diameter
FUEL TANK (sold separately)– Standard Tank Single wall, 250 gallon /
946.35 liter workbench– Optional Tank Double wall workbench
available
ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit
SHIPPING WEIGHT– System with Standard Tank 1237 lbs / 561 kg– System without Tank 812 lbs / 369 kg
STANDARD FEATURES: Integrated Air Compressor, Barometric Damper, Draft Gauge
OPTIONAL FEATURES: Various Size Fuel Tanks
COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil
FUEL METERING PUMP Precision metering over a wide range of fuels
UL CERTIFICATION UL listed system
FUEL FLOW RATE 3.6 gallons / 13.6 liters per hour
BTU INPUT 499,000 BTU / 146 kW per hour
WATER OUTPUTTEMPERATURE (MAX.) 230°F / 110°C
DOMESTIC HOT 8.0 gallons / 30 liters per minute WATER OUTPUT at 100°F / 37.8°C temp rise
HEAT EXCHANGER Wet floor based design
BOILER CAPACITY 52 gallons / 196.84 liters
SYSTEM DIMENSIONS 45”H x 32”W x 68”D /114cm H x 82cm W x 173 cm D
HOUR METER Analog (Clocks only actual burn time)
EXHAUST FLUE DIAMETER 10” / 25.4 cm diameter
FUEL TANK (sold separately)– Standard Tank Single wall, 250 gallon /
946.35 liter workbench– Optional Tank Double wall workbench
available
ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit
SHIPPING WEIGHT– System with Standard Tank 1550 lbs / 703 kg– System without Tank 1125 lbs / 510 kg
STANDARD FEATURES: Integrated Air Compressor, Barometric Damper, Draft Gauge
OPTIONAL FEATURES: Various Size Fuel Tanks
STORAGE TANK (sold separately)
Optional UL-listed 250 gallon workbench storage tank.
Used-Oil Boiler Model 375
COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil
FUEL METERING PUMP Precision metering over a wide range of fuels
UL CERTIFICATION UL listed system
FUEL FLOW RATE 2.7 gallons/10.2 liters per hour
BTU INPUT 375,000 BTU / 109 kW per hour
WATER OUTPUTTEMPERATURE (MAX.) 230°F / 110°C
DOMESTIC HOT 6.0 gallons / 22 liters per minute WATER OUTPUT at 100°F / 37.8°C temp rise
HEAT EXCHANGER Wet floor based design
BOILER CAPACITY 43 gallons/162.75 liters
SYSTEM DIMENSIONS 50”H x 28”W x 54.25”D / 127 cm H x 71 cm W x 138 cm D
HOUR METER Analog (Clocks only actual burn time)
EXHAUST FLUE DIAMETER 8” / 20.32 cm diameter
FUEL TANK (sold separately)– Standard Tank Single wall, 250 gallon /
946.35 liter workbench– Optional Tank Double wall workbench
available
ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit
SHIPPING WEIGHT– System with Standard Tank 1450 lbs / 656 kg– System without Tank 1025 lbs / 464 kg
STANDARD FEATURES: Integrated Air Compressor, Barometric Damper, Draft Gauge
OPTIONAL FEATURES: Various Size Fuel Tanks
ASME Certified, meets NFPA standards
BOILER APPLICATIONS• In-Floor Radiant Heating • Car and Truck Washes • Paint Booths • Ice Prevention• Heating • Make-Up Air • Evaporation • Hot Water • Potable Hot Water • Dishwashers • Truckstops • Supplement to HVAC Systems
Parts Heat Exchanger
energylogic 3 years 10 years*Industry Average 1 year 10 years**
THE INDUSTRY’S MOST COMPREHENSIVE WARRANTY*
EL-500 B
For more informat ion about EnergyLog ic products p lease v is i t www.energylog ic .com or cal l 1-800-311-8828.
EL-375 B
* North American Warranty
BoilerSpecSheet 11/29/06 1:08 PM Page 2
Advantages of the Black Gold Boiler
Proven burner performance; generally all that is required is supply of burnable fuel, occasional
fuel filter change, ash cleanout every 500 hours & an annual preventative maintenance.
Serviceability, Simple to maintain Swing-away burner door assem ly for easy access to chamber and boiler tubes b Straight through ash clean out, 10 minutes instead of half a day
Compact boiler size per BTU output - Convenient to locate in separate boiler/furnace room
32" width 50" length 40" height or attached /detached shelter. Flexible hydronic heat, routing throughout various rooms & adjacent buildings. Quiet, versatile heat.
A competitive price with more features
Steel boiler to eliminate rusting and better heat conductivity than cast iron
Burner has own integral air compressor. No need to use shop air when unattended.
Fuel Metering Pump that automatically handles different viscosity's of fuel, no regulators to
adjust or clean. This means less ash build up and improved efficiency.
Boiler has additional domestic hot water coil as optional equipment. Versatile, on-demand hot water available. - Supplying fresh potable hot water for washeterias, laundries, showers, equipment washing, etc.
UL listed so there is never a problem with your insurance.
Best Warranty in the Industry:
Three year on parts Ten year limited warranty on heat exchanger
Black Gold Boiler utilized by the Port of Kodiak for 9 years, since July 1997. Supplying heat and hot water to their Harbor rest & wash room facilities. (Port of Kodiak contact: Lonnie White, Deputy Harbormaster, 486-8080)
M4
Clean ash from the heat exchangerand flue about every 500 hours ofoperation as indicated by the hourmeter.
Tools Needed: 1/2” Socket, 5/16Socket, 3/4 Open End Wrench,Chimney Brush, Small Pipe Brush,Work Gloves, Dust Mask or Respirator,Large Trash Bag, Box
Warning: Turn off power at the circuitbreaker before beginning this service.Wear protective clothing, includinggloves and a dust mask or respirator.
Allow heater to cool.
Disconnect 3/8 copper fuel line where itconnects to the burner preheaterassembly.
Unplug the burner.
Remove the 2 nuts from the hingedaccess door and swing the door open.
Use a small wire brush to clean all themetal surfaces of the heat exchanger.Lightly brush the ash off of the hingeddoor and the burner air tube, takingcare not to damage the insulation. Youmay use a shop vacuum to remove theash also.
Remove back access panel by theremoving the nuts. The panel will behave ash buildup on it. Position a boxunderneath it to catch the ash.
Lightly tap the flue and allow the ash tofall into the box. Run a chimney brushinto the flue to remove ash buildup.
Reattach the back access panel.
Swing the hinged door closed.Reinstall the nuts and connect the fuelline.
Plug the burner in. Allow 15 minutes for
Unplug the burner
Clean the boile r tubes
Clean the combustionchamber
Remove the flueaccess panel toclean flue.
Copperfuel line
BLACKG OLD
Rev A 02.06.03
Hot WaterSupply 1.5" NPT
Temperatureand Pressure Gauge
Return1.5" NPT
30 psi ASMERelief Valve
Burner
Low WaterCutoff
Heat ExchangerAccess Door
8" Flue
DomesticCoil
Black Gold Model 200 Boiler Installation Cut Sheet - Page 1
3/4" NPT
1.5" NPT
Right Side
FrontBurner Side
Left Side
BreachClean out
CabinetWiring Box
3/4" NPT
50“
21“ 28“
Manual ResetHigh LimitAquastat
12“
Aquastat
39.5“
BackFlue Side
DomesticCoil
Aquastat
Boiler Description: Horizontal fire tube boiler constructed of welded, hydrostatically tested,1/4 inch ASME quality steel boiler plate. Horizontal tubes are 2 inch OD by 0.093 wall ASMEquality steel tubing.
Heating process: The combustion chamber is surrounded by water on all sides but thethe burner side. The combustion gas turn back on itself in the cylindrical combustion chamberand enters the 25 horizontal tubes which are surrounded by water. The water absorbs heatfrom the flue gas. Flue gas then exits the boiler vessel and is exhausted out the flue assembly.
Boiler vessell has room at the top for one domestic copper coil heat exchanger for heating ofpotable process water.
Height Including Relief Valve and High Limit Aquastat mounting tee 45”Width Including Controls 32”Depth Including Burner 50”Additional Spacing for Installation:
6” Top and Piping24” Burner Side (Front)6” Sides18” Back Side and Flue Connections
Flue size: 8 inch diameter, 8 x 8 x 7 inch flue tee with 7" barometric damper includedBoiler Water Capacity: 30 GallonsLow Water Cutoff: ITT McDonnell & Miller 750P-MT-120 Manual reset per UL and ASME CodesTriple Aquastat Relay: Honeywell L8124A or CHoneywell Manual Reset High Limit per UL and ASME Codes OperatingWater Pressure: 30 psi Max.Operating Temperature: 230° F Max.Domestic Hot Water Coil Rating: 8.0 GPMDomestic coil connections: 3/4" NPTComplete System UL Tested and ListedBoiler A.S.M.E. CertifiedShipping Weight With Burner: 662 lbs.Wet Weight: 1000 lbs.
COMBUSTION SPECIFICATIONSAtomizing Air Presssure: 9-11 psiFuel Flow Rate: 1.40 gph max.Input btuh: 199,000 max. Heating Capacity 5,000 Sq. Ft. with 16 ft. ceilingsInput Voltage: 120 VAC 60 HzControl Voltage: 24 VACOperating Current: 8.1 AmpsUL Approved Fuels: Used Crankcase Oil, Used ATF, #2 Fuel Oil
BOILER PIPING CONNECTIONS:1.5” NPT Supply port at the back of boiler top.1.5” NPT Return port at center of boiler backAquastat port: 1/2" NPTLow Water Cutoff port: 3/4" NPTTemperature and Pressure Relief Valve port: 3/4" NPTHigh Limit Control port: 1/2“ NPT
Black Gold Model 200 Boiler Installation Cut Sheet - Page 2
NUERA CORPORATION E-mail: [email protected] Box 5357, Kent WA 98064-5357 1-800-347-9575 AK: 907.345.6411
Pricing: Energy Logic/
Black Gold Equipment & Accessories* FOB Seattle (Effective 5-1-08)
EL140H - MODEL 140 FURNACE (140,000 BTU, 350#) $5,598 hEL200H - MODEL 200 FURNACE (200,000 BTU, 380#) $5,998 EL340H - MODEL 340 FURNACE (340,000 BTU, 530#) $7,998 Furnace included accessories: Three Year Parts Warranty, Integral Air Compressor, High Temp Stainless Steel Chamber/Heat Exchanger, Fuel Metering Pump, Squirrel Cage Ductible Blower, Filtration w/ Spin-on Filter & Vacuum Gauge, Thermostat, Barometric Damper, Draft Gauge, Hour Meter, Pre-wired Electrical Harnesses, & Misc. EL200B - BOILER 200 (200,000 BTU, 810#) $8,680 Add for domestic hot water coil (4 gpm) @ $375 EL375B - BOILER 375 (375,000 BTU, 1030#) $11,980 Add for domestic hot water coil (6 gpm) @ $415 EL500B - BOILER 500 (500,000 BTU, 1175#) $15,980 Add for domestic hot water coil (8 gpm) @ $475 OPTIONS: h250 Gallon workbench tank (410#) $1,298 hPlumbing & hrdw. pkg., tank gauge, furnace stand $194 _Spare parts pkg; nozzle, gasket set, 2 ea. spin-on filters $ 89 _Oil drain pan to tank, 16”x18” w/ screen $ 139 _Low fuel level cut off float switch $ 179 _Furnace ash cleanout kit (hvy. duty F/G rod, scraper, chimney brush) $ 89 _Flue materials (standard through ceiling chimney package $ 595 with 6" Metalbestos) (8" Metalbestos pkg @ $695) _Complete turn-key INSTALLATION package: materials and labor $1,000 (variable with travel requirements and building parameters). Customer supplies 120 volt, 20 amp circuit to eq. & permitting if req. hEL200H-CS - Model 200 COMPLETE SYSTEM Furnace Package (Includes Workbench Tank, $7,490 Stand & Gauge, Plumbing & Hrdw. Pkg.) Customer installed hEL340H-CS - Model 340 COMPLETE FURNACE SYSTEM (with options h above) $9,490 TERMS: Initial 50% deposit; balance upon delivery/installation Lease/Purchase programs available, seasonal offers @ 0% interest, OAC *Prices subject to change without notice. Satisfaction Guaranteed.
COMPETITIVE PRICING GUARANTEED
We guarantee the best price for your Black Gold System. Contact Steve for details. by
Adding Profit to Your Business