block a front elevation - the website shop · coloured front panel 7. window - opening section 8....

1
49500 34000 02 - A - GROUND FLOOR 37000 03 - A - FIRST FLOOR 40000 04 - A - SECOND FLOOR 43000 05 - A - THIRD FLOOR 46000 06 - A - PENTHOUSE 49000 07 - A - ROOF LEVEL 3000 3000 3000 3000 3000 15000 2. 2. 2. 3. 3. 4. 3. 3. 1. 2. 1. 2. 2. 2. 9. 9. 50152 METAL OUTSHOT PARAPET 48660 Level 40 9. 9. 9. 9. 9747 12365 16065 57465 34000 34000 7. 2. 1. 1. 9. 9. 9. 9. 9. 1. MATERIAL LEGEND 1. SELECTED ENGINEERED BRICK 2. CURTAIN WALLING SYSTEM - SILVER GREY PPC FRAMEWORK / SILVER GREY PPC SPANDRELS AND CLEAR GLAZING 3. CURTAIN WALLING SYSTEM - SILVER GREY PPC FRAMEWORK / SILVER GREY PPC SPANDRELS AND OPAQUE GLAZING 4. GLAZED GUARDING 5. BALCONY DOOR 6. COLOURED FRONT PANEL 7. WINDOW - OPENING SECTION 8. RECESSED ENTRANCE 9. FEATURE ALUMINIUM PANELTO SELECT COLOUR 10. ZINC STANDING SEAM 15000 3000 3000 3000 3000 3000 47100 34000 02 - A - GROUND FLOOR 37000 03 - A - FIRST FLOOR 40000 04 - A - SECOND FLOOR 43000 05 - A - THIRD FLOOR 46000 06 - A - PENTHOUSE 49000 07 - A - ROOF LEVEL 6. 6. 4. 5. 1. 7. 2. 2. 3. 2. 2. 2. 9. 9. 9. 5. 5. 4. 4. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 9. 2. 1. 1. 1. 9. 9. 9. 9. 9. 9. 9. 9. 50152 METAL OUTSHOT PARAPET 48660 Level 40 57465 15534 12680 8541 13532 34000 10. 10. 10. Cathedral Court New Street Dublin 8 Ireland D08 YY51 T: +353-1 491 1700 [email protected] www.dmod.ie Client: Project: Drawing Title: Job Number: Drawing Number: Drawing Reference: Scale: Date Created: Revision: Author: . . .Rev. Do not scale. Use figured dimensions only. All dimensions to be checked on site. Any discrepancies between site and figured dimensions to be brought immediately to the architect's attention. Digital copies cannot be guaranteed. Only information in hard copy can be relied upon for conformity and accuracy. c This drawing is copyright. OS maps are produced under Ordnance Survey Ireland Licence No. AR 0031117. c Ordnance Survey Ireland and Government of Ireland. GENERAL NOTE Any deviation from the proposed specifications to be brought immediately to the architect's attention. All product substitutions to meet the project performance requirements and the minimum requirements of the Building Regulations. All products to be installed in strict accordance with the manufacturer's specification. Any discrepancies between site and figured dimensions to be brought immediately to the architect's attention. Subcontractors to confirm site dimensions with the main contractor prior to manufacture. Subcontractors to supply fabrication drawings to the architect for approval or comment prior to manufacture. All sub-structure, structural steelwork and reinforced concrete to structural engineer's design, detail and specification. Structural precast concrete elements by specialist subcontractor. Any inconsistencies between structural and architectural drawings to be brought immediately to the architect's attention. Stage: ISSUED FOR PLANNING B 10/01/18 B 1 : 100 B DH MD 0151 DH BLOCK A - ELEVATIONS Fassaugh Ave 16047 15/08/17 Labinies Ltd. 16047 PLANNING AP 0151 AP 1 : 100 BLOCK A REAR ELEVATION 2 1 : 100 BLOCK A FRONT ELEVATION 1

Upload: others

Post on 20-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BLOCK A FRONT ELEVATION - The Website Shop · coloured front panel 7. window - opening section 8. recessed entrance 9. feature aluminium panelto select colour 10. zinc standing seam

49500

34000

02 - A - GROUND FLOOR

37000

03 - A - FIRST FLOOR

40000

04 - A - SECOND FLOOR

43000

05 - A - THIRD FLOOR

46000

06 - A - PENTHOUSE

49000

07 - A - ROOF LEVEL

3000

3000

3000

3000

3000

15000

2.2. 2. 3.3. 4.

3.3.

1.2.

1. 2.2.2.

9.

9.

50152

METAL OUTSHOT PARAPET

48660

Level 40

9.

9.

9.9.

9747

12365

16065

57465

34000 34000

7. 2.1.1.9.9.9.9.9. 1.

MATERIAL LEGEND

1. SELECTED ENGINEERED BRICK2. CURTAIN WALLING SYSTEM - SILVER GREY PPC FRAMEWORK / SILVER GREY PPC SPANDRELS AND CLEAR GLAZING3. CURTAIN WALLING SYSTEM - SILVER GREY PPC FRAMEWORK / SILVER GREY PPC SPANDRELS AND OPAQUE GLAZING4. GLAZED GUARDING5. BALCONY DOOR6. COLOURED FRONT PANEL7. WINDOW - OPENING SECTION8. RECESSED ENTRANCE9. FEATURE ALUMINIUM PANELTO SELECT COLOUR10. ZINC STANDING SEAM

15000

3000

3000

3000

3000

3000

47100

34000

02 - A - GROUND FLOOR

37000

03 - A - FIRST FLOOR

40000

04 - A - SECOND FLOOR

43000

05 - A - THIRD FLOOR

46000

06 - A - PENTHOUSE

49000

07 - A - ROOF LEVEL

6.6.

4.5.

1.

7.

2.2.

3.

2. 2.

2. 9.

9. 9.

5. 5. 4.4.

9.

9. 9. 9. 9. 9. 9. 9. 9. 9.

9. 9. 9. 9. 9. 9. 9. 9.

2.1. 1. 1.

9. 9. 9. 9. 9. 9. 9. 9.

50152

METAL OUTSHOT PARAPET

48660

Level 40

57465

15534

12680

8541

13532

34000

10. 10. 10.

Cathedral CourtNew StreetDublin 8IrelandD08 YY51

T: +353-1 491 [email protected]

Client:

Project:

Drawing Title:

Job Number:

Drawing Number:

Drawing Reference:

Scale:

Date Created:

Revision:

Author:

. . .Rev.

Do not scale. Use figured dimensions only. All dimensions to be checked on site.Any discrepancies between site and figured dimensions to be broughtimmediately to the architect's attention. Digital copies cannot be guaranteed.Only information in hard copy can be relied upon for conformity and accuracy.c This drawing is copyright.

OS maps are produced under Ordnance Survey Ireland Licence No.AR 0031117. c Ordnance Survey Ireland and Government of Ireland.

GENERAL NOTEAny deviation from the proposed specifications to be brought immediately to thearchitect's attention. All product substitutions to meet the project performancerequirements and the minimum requirements of the Building Regulations. Allproducts to be installed in strict accordance with the manufacturer's specification.Any discrepancies between site and figured dimensions to be broughtimmediately to the architect's attention. Subcontractors to confirm sitedimensions with the main contractor prior to manufacture. Subcontractors tosupply fabrication drawings to the architect for approval or comment prior tomanufacture.All sub-structure, structural steelwork and reinforced concrete to structuralengineer's design, detail and specification. Structural precast concrete elementsby specialist subcontractor. Any inconsistencies between structural andarchitectural drawings to be brought immediately to the architect's attention.

Stage:

ISSUED FOR PLANNINGB 10/01/18

B 1 : 100

B

DH MD

0151

DH

BLOCK A - ELEVATIONS

Fassaugh Ave

16047

15/08/17

Labinies Ltd.

16047

PLANNING

AP 0151

AP

1 : 100

BLOCK A REAR ELEVATION2

1 : 100

BLOCK A FRONT ELEVATION1