bre global classification report
TRANSCRIPT
BRE Global Classification Report
Kooltherm K15 Zero ODP Phenolic Insulated Rainscreen system. Classification of fire performance in accordance with BR 135: 2013 Annex A
Prepared for:
Date:
Report Number:
BRE Global Ltd Watford, Herts WD25 9XX
Kingspan Insulation Ltd
14 September 2015
P101812-1000 Issue 1
Customer Services 0333 321 8811
From outside the UK: T F E [email protected] www.bre.co.uk
Prepared for: Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA
BRE00005091_0001 BRE00005091/1
Classification of fire performance in accordance with BR 135: 2013 Annex A.
Prepared by
Name Vida Gaubsaite
Position Certification Scheme Manager
Date 14 September 2015
Signature
Authorised by
Name Stephen Howard
Position Principal Consultant
Date 14 September 2015
Signature
Report Number:P101812-1000 Issue:
11
This report is made on behalf of BRE Global and may only be distributed in its entirety, without amendment, and with attribution to BRE Global Ltd to the extent permitted by the terms and conditions of the contract. Test results relate only to the specimens tested. BRE Global has no responsibility for the design, materials, workmanship or performance of the product or specimens tested. This report does not constitute an approval, certification or endorsement of the product tested and no such claims should be made on websites, marketing materials, etc. Any reference to the results contained in this report should be accompanied by a copy of the full report, or a link to a copy of the full report.
BRE Global's liability in respect of this report and reliance thereupon shall be as per the terms and conditions of contract with the client and BRE Global shall have no liability to third parties to the extent permitted in law.
Opinions and interpretations expressed herein are outside the scope of UKAS Accreditation
Commercial in Confidence © BRE Global Ltd 2015 Page 1 of 11
BRE00005091_0002 BRE00005091/2
Classification of fire performance in accordance with BR 135: 2013 Annex A.
Table of Contents
1 Introduction
2 Details of the Classified Product
2.1 Description of substrate
2.2 Description of product
2.3 Installation of cladding System.
2.3.1 Fixing details
2.4 Installation of Specimen
3 Product Specification
4 Supporting Evidence
4.1 Test reports
4.2 Test results
4.3 Mechanical Performance
5 Classification and field of application
5.1 Reference of classification
5.2 Classification
5.3 Field of application
6 Limitations
Commercial in Confidence © BRE Global Ltd 2015
Report Number:P101812-1000 Issue:
11
4
5
5
5
5
5
5
6
8
8
8
9
10
10
10
10
11
Page 2 of 11
BRE00005091_0003 BRE00005091/3
Classification of fire performance in accordance with BR 135: 2013 Annex A. Report Number:P101812-1000 Issue:
11
CLASSIFICATION OF FIRE PERFORMANCE IN ACCORDANCE WITH BR 135:2013 Annex A
Sponsor: Kingspan Insulation Ltd, Pembridge, Leominster, Herefordshire HR6 9LA
Prepared by: BRE Global Ltd, BRE, Bucknalls Lane, Garston, Watford, WD25 9XX, England
Product name: Kooltherm K15 Zero ODP Phenolic Insulated Rainscreen System
Classification report No.: P1 01812-1000
Issue number:
Date of issue: 14 September 2015
This classification report consists of 15 pages and may only be used or reproduced in its entirety.
Commercial in Confidence © BRE Global Ltd 2015 Page 3 of 11
BRE00005091_0004 BRE00005091/4
Classification of fire performance in accordance with BR 135: 2013 Annex A.
1 Introduction
Report Number:P101812-1000 Issue:
11
This report presents the classification of the system detailed in section 2. The classification is carried out in accordance with the procedures given in BR 135 - 'Fire performance of external thermal insulation for walls of multi-storey buildings', Third edition, Annex A 2013. This classification should be read in conjunction with this document and the associated test reports referenced in section 4.
Commercial in Confidence © BRE Global Ltd 2015 Page 4 of 11
BRE00005091_0005 BRE00005091/5
Classification of fire performance in accordance with BR 135: 2013 Annex A.
2 Details of the Classified Product
2.1 Description of substrate
Report Number:P101812-1000 Issue:
11
The specimen was installed on to the right hand face of the BRE Global External Cladding Test Facility. This is a multi-faced test facility constructed from low-density concrete blocks on to which the test specimen was installed.
2.2 Description of product
Trade name and specimen identification code or number: Koltherm K15 Zero ODP Phenolic Rainscreen Insulation Board. Colour: Grey/Cream or Red Kooltherm K15 Zero ODP Phenolic Rainscreen Insulation Board with foil finish top and bottom.
2.3 Installation of cladding System
2.3.1 Fixing Details
60mm thick Kooltherm K15 Zero ODP Phenolic Rainscreeen Insulation Board wich were 1200x900 mm was mechanically fixed to the block work substrate. 1200mmx900mmx6mm thick cement particle boards, manufactured by UAC, were mechanically fixed at 600 mm centres to an aluminium railing system which was also mechanically fixed to the block work substrate. The cement boards provided the overcladding for the rainscreen system. A40 mm deep ventilated cavity was provided between the Kooltherm K15 Zero ODP Phenolic Rainscreen Insulation Board and the cement particle board. Fire stopping was provided by a ventilated rainscreen barrier system, comprising of nominal 2.5 mm thick graphite based intumescent strip bonded to nominal 0.6 mm thick galvanised steel sheet, and positioned 0.5 m and 4 m above the fire chamber on both the main face and the wing face (Full manufactures details are held on file).
No other material details were supplied.
The specimen area was 8.4 mx 2.70 m on the main face and 8.4 m x1.8 m on the wing face. The panel layout is given in Figure 1.
All test materials were supplied by the sponsor. BRE were not involved in the sample selection process and therefore cannot comment upon the relationship between samples supplied for test and the product supplied to market.
2.4 Installation of Specimen
The test sponsor undertook the supply and installation of the test specimen. BRE staff undertook no supervision of this process.
Commercial in Confidence © BRE Global Ltd 2015 Page 5 of 11
BRE00005091_0006 BRE00005091/6
Classification of fire performance in accordance with BR 135: 2013 Annex A.
3 Product Specification
Page deliberately left blank
Commercial in Confidence © BRE Global Ltd 2015
Report Number:P101812-1000 Issue:
11
Page 6 of 11
BRE00005091_0007 BRE00005091/7
OJ ::0 m 0 0 0 0 01 0 (0 ...... 10 0 0 (X)
0 0 3 3 CD Cl ~ :;· 0 0 :::l
"" Q.
CD :::l
" CD
@ Ill ::0 m G) 0 C" ~
!:: Q.
"' 0
~
"U
"' cc CD ..... a
, IS' c .., CD ..... "'tt .., 0 a. c n -a. CD -e!. iii
40 X 40 X 2 Alv VINIUM ANGLE FULL LENGTH r
IJITL'Nl ..!JD<T
I ~ ' 0 0 ..,. a)
CO!iPtt R tUt~oJt. QU DUI..1
~ 9001 350 900 900 ,5SO
H :') 0
. I : N -
0 0 N - . I
)(
0
. f.· I 0
:::' D 11
' 0 1 0 N -
0 0 :::'
w t I _
I / \ .
' '
I ~ /< , . Bo
0 .
j / J ' tr-- ~-----:
r-' ~ X o c 0 ' 8
11 c 0 N
- ~ \. __ !._~
>•N(l. lllCl
0 0 a . N -
' 1
w t J ! 1.
250 11 2000 1 1
270() , .. · ··· - 1
CO:>S1'RUCTIO~ DATE I TITLE
>6/ 05/05 BS84H : PART 1 KINGSPAN KOOLTIIERM K15 RA I :VSCREE~ TEST
PROJECT Nu:IWER
03167
rrtila!ed lvity
ier 2
r>tilated avity Qt'T\er 1
LEf£J<j.
X ""' n~ ~ ()U'xlk;: tmllT> ~ err :t(OIJI~~
a "'"" rox 9(1'! <r...~:o ~Nn ~· CFF' OARtll
L4'Pt:f'(t1: Vf)l' ':!Al Ill 301» l£'<,THS
t~X:[J'tL( V0:¥:.c..r.L U J1. XCt lDoGtJ.CS.
8 N
0
·~ gl
q,lA.. •·•O~Er Lo\Yil.lf
SCALE
1:50
DRAWING .'lUMBER
002
0 ;;; "' "' ::;; r;· a a· :::l
a ... ~·
"0
"' 3-3 ., :::l ()
"' :;· ., () ()
0 a. ., :::l
" "' =: ;:;: :::r tu ;u ~
"' ~ "' ~ "' )> :::l :::l
"' >< ;>
...... ;c CD
"0 0 ::t. z " 3 C"
~ ~ 0
~
~ 0 0 0
"iii "' " (!)
BR
E00005091/8
Classification of fire performance in accordance with BR 135: 2013 Annex A.
4 Supporting Evidence
4.1 Test reports
Name of Name of sponsor
Test reports/extended Laboratory application report Nos.
BRE Global, Kingspan Test report 220876
BRE Insulation Limited
4.2 Test results
Test method & Parameter No. Fire spread test number tests test result
time, ts (min)
External fire spread >15 minutes
Cavity behind >15 minutes
rainscreen (cavity 1)
Internal fire spread 1 >15 minutes BS 8414-1: 2002 Insulation layer
Cavity formed by >15 minutes
Steel frame (cavity 2)
Internal fire spread >15 minutes Burn through
Commercial in Confidence © BRE Global Ltd 2015
Report Number:P101812-1000 Issue:
11
Test method I extended application rules & date
BS 8414-1: 2002
Results
Compliance with parameters in Annex B
BR135:2013
Compliant
Compliant
Compliant
Compliant
Compliant
Page 8 of 11
BRE00005091_0009 BRE00005091/9
Classification of fire performance in accordance with BR 135: 2013 Annex A. Report Number:P101812-1000 Issue:
11
4.3 Mechanical Performance
The test was terminated on the 49 minutes.
On the main face, the cement board overcladding was detached up to height of 4.00 m and to a width of 2.15 m at its widest point above the head of the fire chamber. The cement particle board was discoloured to the full height of the test sample and to a width of 2.15 m, from the internal corner, 0.5 m above the head of the fire chamber, and a width of 0.5 m, 6.4 m above the head of the fired chamber. The aluminium railing system was burnt away to a height of approximately 3.0 m above the centre line of the fire chamber an to 0.9 m to the left of the centre line.
On the wing face, the cement particle board had detached from 2.00 m (floor level) to 3.00 m above the head of the fire chamber. The panels were detached to 0.90 m from the internal corner.
On the main face, the Kooltherm K15 Zero ODP Phenolic Rainscreen Insulation board (foil faces and insulation material) had been consumed to a height of 3.60 m above the head of the fire chamber and a width a maximum width of 1.70 m, exposing the block work substrate to the rear. The phenolic material was discoloured to full height on the centre line and around the area of the upper fire break.
On the wing face, the foil face of the Kooltherm K15 Zero ODP Phenolic Rainscreen Insulation Board was detached and the phenolic boards partially consumed to 3.00 m above the head of the fire chamber. On no part of the wing face had the Kooltherm K15 Zero ODP Phenolic Rainscreen Insulation Board been full consumed to expose the block work substrate.
Details of this are given in the table below.
Time
10:39
17:01
20:51
21:59
28:06
29:43
30:00
49:00
Commercial in Confidence
Location of panel
Cement board falls away from main face, insulation core exposed.
Half of the cement board 2.4 m and 3.6 m of main face on left of centre line falls off.
Panel between 1.2 m and 3.6 m on right of main face falls. Causes damage to wing face between 0 m and- 0.9 m.
Flames on wing from behind 0 m and -2.0 m. Area where falling cement boards caused damage.
Flaming on wing between 0 and 2.4 m.
Flaming on main face at 4.8 m.
Crib Extinguished. Intermittent flaming continues on wing face.
All flaming out.
© BRE Global Ltd 2015 Page 9 of 11
BRE00005091_001 0 BRE00005091/10
Classification of fire performance in accordance with BR 135: 2013 Annex A.
5 Classification and field of application
5.1 Reference of classification
Report Number:P101812-1000 Issue:
11
This classification has been carried out in accordance with Annex B of BR 135 - 'Fire performance of external thermal insulation for walls of multi-storey buildings.' Third Edition 2013.
5.2 Classification
The system described in this classification report has been tested and met the performance criteria set in Annex A of BR 135:2013.
5.3 Field of application
This classification is valid only for the system as installed and detailed in Section 2 of this classification report and the associated details found in the related test reports, referenced in Section 4.
Commercial in Confidence © BRE Global Ltd 2015 Page 10 of 11
BRE00005091_0011 BRE00005091/11
Classification of fire performance in accordance with BR 135: 2013 Annex A.
6 Limitations
Report Number:P101812-1000 Issue:
11
This classification document does not represent type approval or certification of the product.
The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons, it is recommended that the relevance of test and classification reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test or classification to ensure that they are consistent with current practices, and if required may endorse the report.
This classification report is issue 1 of report P1 01812-1000. This report contains up issued drawings included at the client's request.
Commercial in Confidence © BRE Global Ltd 2015 Page 11 of 11
Report Ends