bt-st-302dr - dmctools...contact dmc if a translation is needed. 2 specifications head type square...

29
BT-ST-302DR ELECTRONIC TORQUE-ANGLE WRENCH

Upload: others

Post on 24-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

BT-ST-302DR

ELECTRONIC

TORQUE-ANGLE

WRENCH

Page 2: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

1

IMPORTANT SAFETY INSTRUCTIONS

WARNING Risk of flying particles.

Over-torquing can cause breakage. Force against flex stops on flex head can cause head breakage. An out of calibration angle wrench can cause part or tool breakage. Broken hand tools, sockets or accessories can cause injury. Excess force can cause crowfoot or flare nut wrench slippage.

Read this manual completely before using ELECTRONIC WRENCH.

To ensure accuracy, work must not move in angle mode.

For personal safety and to avoid wrench damage, follow good professional tool and fastener installation practices.

Periodic recalibration is necessary to maintain accuracy.

Wear safety goggles, user and bystanders.

Be sure all components, including all adaptors, extensions, drivers and sockets are rated to match or exceed torque being applied.

Observe all equipment, system and manufacturer's warnings, cautions and procedures when using this wrench.

Use correct size socket for fastener.

Do not use sockets showing wear or cracks.

Replace fasteners with rounded corners.

To avoid damaging wrench: Never use wrench with power off. Always turn ON wrench so applied torque is being measured.

Do not press POWER while torque is applied or while wrench is in motion.

Never use this wrench to break fasteners loose.

Do not use extensions, such as a pipe, on handle of wrench.

Check that wrench capacity matches or exceeds each application before proceeding.

When using negative offsets, verify maximum targets are not exceeded (see tables on page 6).

Verify calibration if dropped.

Make sure ratchet direction lever is fully engaged in correct position.

Verify calibration of wrench if you know or suspect its capacity has been exceeded.

Do not force head of flex head drives against stops.

Always adjust your stance to prevent a possible fall should something give while using wrench.

Do not attempt to recharge lithium cells.

Store wrench in dry place.

Remove batteries when storing wrench used for periods longer than 3 months.

WARNING Electrical Shock Hazard. Electrical shock can cause injury. Metal handle is not isolated. Do not use on live electrical circuits.

SAVE THESE INSTRUCTIONS

Disclaimer Operation of BT-ST-302DR is not warranted in an EU member state if operating instructions are not in that State’s language. Contact DMC if a translation is needed.

Page 3: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

2

Specifications

Head Type

Square drive 72 teeth, sealed flex and fixed ratchet

Fixed 3/8" square drive

Reversed Head Design

Display

DISPLAY TYPE: Dot Matrix LCD (168 x 48 Resolution)

VIEWING ANGLE: 6:00

BACKLIGHT: WHITE (LED)

Sealed Button Pad

POWER - ON/OFF and torque and angle re-zero

ENTER - measurement mode select and menu entry

UP – increments torque and angle settings and menu navigation

DOWN - decrements torque and angle settings and menu navigation

UNITS - units select (ft-lbs, in-lbs, Nm, Kg-cm, dNm) and enter PSET (preset) menu

LCD BACKLIGHT – Illuminates all screens and last peak torque or angle recall

Functions

Set - torque or angle target

Track - real time display of torque or accumulated angular rotation with progress lights

Peak Hold – 5 sec. flashing of peak torque or alternating peak torque/angle on release oftorque

Peak Recall - display last peak torque or peak torque/angle on button press

Memory - display of last 1500 peak torque or peak torque/angle readings

Accuracy

Temperature: @ 22 C (72°F)

Angle: ±1% of reading ±1° @ angular velocity > 10°/sec < 180°/secCW CCW

Torque: ±2% ±3% of reading, 20% to 100% of full scale (unflexed) ±4% ±6% of reading, 5% to 19% of full scale

Operating Temperature: 0°F - 130°F (-18°C to 54°C)

Storage Temperature: 0°F to 130°F (-18°C to 54°C)

Measurement Drift: ANGLE: -0.12 Angular Degrees per Degree C

TORQUE: +0.01% of reading per Degree C

Humidity: Up to 90% non-condensing

Battery: Single "AA" Lithium Cell, up to 40 hours continuous operation

Default Auto Shut-off: After 2 minutes idle – (Adjustable, see Advanced Settings)

Page 4: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

3

User Instructions

Basic Functions (Quick Start)

Figure 1

Install fresh Lithium “AA” cell into handle of wrench.

Wrench Power On Sequence

Note: Do not turn on wrench while torque is applied, otherwise torque zero offset will be incorrect and wrench will indicate a torque reading when torque is released. If this occurs, re-zero wrench by momentarily pressing POWER button while wrench is on a stable surface with no torque applied.

1. Turn On Wrench.While holding wrench still, momentarily press POWER button. DMC logo will be displayedfollowed by torque and angle re-zeroing screens (if angle mode has been previously selected). If real-time-clock has not been set, date and time entry screens are displayed (see Advanced Configuration section for entering date and time). After entering date and time or if time has been previously set, target TORQUE or ANGLE screen will now be displayed depending on previous measurement mode selected.

2. Select Measurement Mode.Toggle between target TORQUE and ANGLE screens by repeatedly pressing ENTER button.

Note: When date and time is set for first time, In-Service date is also set and is used for calculating initial calibration interval (see "Setting Calibration Interval" in Advanced Configuration section).

MODE COUNT

AUDIBLE ALERT

PROGRESS LIGHTS Yellow - First light indicates 40% of target

torque or angle reached. Second indicates 60% of target reached. Third indicates 80% of target reached.

Green - Indicates target torque or angle reached.

Red - Indicates exceeded torque orangle target plus 4% or exceededmaximum Preset target.

Target Torque Screen

TORQUE ZEROING ANGLE ZEROING -- SET STILL

UP/DOWN buttons

SET DATE 2017/01/01

YR MON DAY

ENTER button

SET TIME 12 : 00 : 00 HR MIN SEC

UP/DOWN buttons

ENTER button

Target Angle Screen

00

250.0 IN-LB

00

180°

MODE SELECT AND MENU ENTRY BUTTON

INCREMENT BUTTON

ON/OFF AND RE-ZERO BUTTON

DECREMENT BUTTON

LCD BACKLIGHT AND

PEAK TORQUE/ANGLE RECALL BUTTON

UNITS AND PRESET ENTRY

BUTTON

TORQUE AND/OR ANGLE DISPLAY

BATTERY CONDITION

USB CONNECTOR

PROGRESS LIGHTS

PROGRESS LIGHTS

DATA STORAGE

ALERT

Page 5: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

4

Note: If wrench is powered up in torque only measurement mode, angle is not zeroed until mode is changed to angle measurement mode, at which time torque and angle zeroing begins automatically after 2 seconds. Wrench should be placed on a stable surface with no torque applied.

Note: Pressing ENTER button while angle is zeroing will abort zeroing function to allow user to select another measurement mode.

Torque Mode

1. Set Target.Use UP/DOWN buttons to change TORQUE target value.

2. Select Units of Measure.Repeatedly press UNITS button while on target TORQUE screen until desired units are displayed.

3. Apply TORQUE.Grasp center of handle and slowly apply torque to fastener until progress lights display green and a ½ second audible alert and handle vibration alerts you to stop.

4. Release TORQUE.Note peak TORQUE reading flashing on LCD display for 5 seconds. Pressing BACKLIGHT button while peak torque is flashing will continue to display value until button is released. Momentarily pressing UP/DOWN, ENTER or UNITS button will immediately return to target TORQUE screen. Reapplying TORQUE will immediately start another TORQUE measurement cycle.

5. Recall Peak TORQUE ReadingTo recall last peak TORQUE measurement, press and hold BACKLIGHT button for approximately 3 seconds. Peak TORQUE will flash for 5 seconds.

Angle Mode

Note: When angle measurement mode is selected for first time following a power on, "ANGLE ZERO REQUIRED" message is displayed. After two seconds angle zero process begins and wrench must be placed on a stable surface. If ENTER button is pressed before two seconds to change to torque only mode, angle zero process is skipped.

1. Set target.Use UP/DOWN buttons to change target ANGLE value.

2. Apply Torque and Rotate Wrench.Grasp center of handle and slowly apply torque to fastener and rotate wrench at a moderate consistent speed until progress lights display green and a ½ second audible alert and handle vibration alerts you to stop.

3. Release torque.Note alternating peak TORQUE and ANGLE readings flashing on LCD display for 5 seconds. Pressing BACKLIGHT button while peak values are flashing will continue to display values until button is released. Momentarily pressing UP/DOWN, ENTER or UNITS button will immediately return to target ANGLE screen. Reapplying torque (ratcheting) before target screen is displayed will continue ANGLE accumulation as wrench is rotated.

4. Recall Peak ANGLE ReadingTo recall last peak ANGLE measurement, press and hold BACKLIGHT button for approximately 3 seconds. Peak TORQUE and ANGLE will be displayed alternately for 5 seconds.

Mode Cycle Count

Mode cycle count feature is used to indicate number of times wrench has reached target torque in torque measurement mode or target angle in angle measurement mode.

01

M 180°

MEMORY ICON MODE CYCLE COUNT

Page 6: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

5

Torque and Angle Mode Cycle Counting

1. Numerical counter located in top right of target torque or target angle screen will increment aftereach torque or angle cycle if applied torque or angle has reached target value.

2. When toggling between torque mode or angle mode using ENTER button or if target is changed,numerical counter will reset back to 00. Counter WILL NOT reset when re-zeroing, on menuentry/exit or power down.

3. Memory icon will turn on indicating at least one torque or angle cycle data has been stored inmemory.

Data Download

Torque and Angle data in memory can be downloaded to a computer via USB port.

Note: When downloading data from a wrench that has previous downloaded data, rename previous file or move it to a different directory to prevent overwrite. However, Windows® will notify user of duplicate file names and allow user to skip download, overwrite existing file or save new file as a second copy.

1. Connect supplied USB cable from computer to wrench.

2. Computer will display "AutoPlay" window showing CTECH as a disk drive with option of usingWindows Explorer to view files:

3. Click "Open Folder" selection to display CTECH Character Separated Value (.csv) file.

Note: If "AutoPlay" does not start automatically, use Explorer to display CTECH drive contents.

4. Open file using Microsoft Excel by double clicking on file name (Example: "1213590002.CSV") or"drag and drop" file to computer.

5. Data on wrench can be cleared by deleting file on CTECH drive.

Main Menu

Main menu displays wrench operational information.

1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Use UP/DOWN buttons to highlight menu selection then press ENTER button.

Menu Selections:

EXIT - Exits Main menu and returns to target screen.

SET HEAD LENGTH - Displays wrench head length entry screen.

SHOW DATA - Displays stored torque and angle data.

Page 7: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

6

CLEAR DATA - Clears stored torque and angle data.

CYCLE COUNT - Displays torque/angle cycle count screen.

LANGUAGE - Displays language selection menu.

SETTINGS - Displays advanced settings menu (see Advanced Settings Section).

CONFIGURE - Displays advanced configuration menu (see Advanced Configuration Section).

Setting Head Length

Note: If wrench has an interchangeable head or an adapter or extension is added, length of head, adapter and/or extension being used can be entered to correct for a different length than head used to calibrate wrench, without requiring re-calibration.

1. To enter a head length, from target torque or angle screen, press and hold ENTER button for 3seconds.

2. With SET HEAD LENGTH menu selection highlighted, momentarily press ENTER button.

3. Set Head Length screen is displayed next. Default head length is length of head at calibration (zerofor fixed head wrench) and is displayed with most-significant digit highlighted. Use UP/DOWNbuttons to increment/decrement head length. Pressing and holding UP/DOWN buttons willprogressively increment/decrement value faster.

4. Press ENTER button to accept digit and highlight next-significant digit.

5. Default units of length is in inches. Press UNITS button to change to millimeters.

6. Pressing ENTER button after least-significant digit is set returns to main menu. If length is changedfrom default, the target torque is highlighted in black.

Note: If UP/DOWN buttons are pressed simultaneously while on Set Head Length screen, displayed head length resets to zero or calibration head length for interchangeable head wrenches.

Note: For a fixed length head, head length entered is offset length measured from center of drive to center of fastener.

𝑜𝑓𝑓𝑠𝑒𝑡

UP/DOWN/ENTER buttons

ENTER button (while least-significant digit highlighted)

00

100.0 IN-LB

ENTER button

held

ENTER button

UNITS button

Target Screen UP/DOWN/ENTER buttons

EXIT SET HEAD LENGTH SHOW DATA

SET HEAD LENGTH

3.000 IN

SET HEAD LENGTH

076.2 MM

00

100.0 IN-LB

Page 8: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

7

Use of Negative Offsets

Note: Enter a negative value for offset when used in reverse direction with flex head or when calculating sum of interchangeable head and offset lengths.

When length of an offset (or sum of head minus offset for interchangeable head) is negative, maximum fastener target is limited by following formulas:

240 in-lb wrench:

Maximum Target Torque = offset * 24 + 240

Offset Max Target -1" 216 in-lb

-2" 192 in-lb -3" 168 in-lb

-4" 144 in-lb

Note: When using a negative offset, entering a target torque greater than maximum values above may cause an overtorque error before reaching fastener target torque and possibly damage wrench.

Viewing Stored Torque and Angle Data

Torque data is stored in memory after each torque cycle if applied torque has reached target value. Torque and angle data is stored in memory after each angle cycle if applied angle has reached target value. Memory Indicator is displayed when data is stored in non-volatile memory.

1. To view stored torque and angle data, from target torque or angle screen, press and hold ENTERbutton for 3 seconds.

2. Highlight SHOW DATA menu selection by pressing UP/DOWN buttons then press ENTER button todisplay Show Data screen.

3. In Show Data screen, scroll through each stored data record by pressing UP/DOWN buttons.

Example: 0002 = Show Data List Counter: TQ = Peak torque value 0001 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value

4. Pressing ENTER button while on Show Data screen returns to main menu.

Note: A maximum of 1500 data records can be stored in memory. Memory full icon will be displayed when full and no more data is stored until memory is cleared.

𝑜𝑓𝑓𝑠𝑒𝑡

UP/DOWN buttons

ENTER button

held

Target Screen

ENTER button

UP/DOWN buttons

00

M 100.0 IN-LB

EXIT SET HEAD LENGTH SHOW DATA

EXIT SET HEAD LENGTH SHOW DATA

0002: 15:40:15 2017/01/26

TQ: 100.2 IN-LBS

0001: 15:35:05 2017/01/26

100.3 IN-LBS 84°

Page 9: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

8

Deleting Stored Torque and Angle Data 1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Highlight CLEAR DATA menu selection using UP/DOWN buttons then press ENTER button to displayCLEAR ALL DATA screen.

3. In CLEAR ALL DATA screen, highlight YES menu selection to delete all stored data, or NO menuselection to exit without deleting data.

4. Press ENTER button after making selection.

Note: If wrench is Locked (see Preset Lock in Advanced section), Clear Data function is disabled.

Viewing and Clearing Wrench Cycle Counter

Each time torque or angle target is reached, wrench cycle counter is incremented. Maximum cycle count is 999999.

1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Highlight CYCLE COUNT menu selection using UP/DOWN buttons.

3. Press ENTER button to display CYCLE COUNT screen.

4. To exit CYCLE COUNT screen without clearing count, press ENTER button while EXIT menu selectionis highlighted.

5. To reset wrench cycle count to 0, highlight CLEAR menu selection then press ENTER button.

6. EXIT menu selection is automatically highlighted after count is cleared. Press ENTER button toreturn to main menu.

Note: If wrench is Locked (see Preset Lock in Advanced section) Clear count function is disabled.

Language 1. To select language menu, press ENTER button while LANGUAGE is highlighted then highlight

desired language and press ENTER button.

2. Decimal Mark selection menu is displayed. Decimal separator can be a comma or decimal point.Use UP/DOWN buttons to select decimal separator then press the ENTER button.

Note: Decimal separator will affect formatting of downloaded data when opened by Excel depending on Windows® regional settings.

ENTER button

held

Target Screen UP/DOWN buttons

ENTER button

ENTER button

00

M 100.0 IN-LB

UP/DOWN buttons

EXIT SET HEAD LENGTH SHOW DATA

SET HEAD LENGTH SHOW DATA CLEAR DATA

CLEAR ALL DATA YES NO

CLEAR ALL DATA YES NO

SET HEAD LENGTH SHOW DATA CLEAR DATA

ENTER button

held

Target Screen UP/DOWN buttons

ENTER button

00

M 100.0 IN-LB

EXIT SET HEAD LENGTH SHOW DATA

UP/DOWN buttons

COUNT: 12 CLEAR EXIT

COUNT: 0 CLEAR EXIT

SHOW DATA CLEAR DATA CYCLE COUNT

ENTER button COUNT: 12

CLEAR EXIT

ENTER button SHOW DATA

CLEAR DATA CYCLE COUNT

ENTER button

Page 10: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

9

3. To exit Main menu and return to target torque or angle screen, press ENTER button while EXITmenu selection is highlighted.

Target Presets (PSET)

PSET function gives user ability to configure 50 preset target torque or target angle settings, each with a target, minimum, maximum (over range) and batch count value. PSETs are stored in non-volatile memory so that they are retained while power is off.

Note: After adding a Preset (see below), navigate between manual target torque, angle mode and PSET screen by repeatedly pressing ENTER button. While PSET screen is displayed, press UP/DOWN buttons to select additional configured PSETs.

Adding a Torque Preset

1. From manual target torque screen, select units of measure.

2. Press and hold UNITS button for 3 seconds.

3. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWNbuttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.

4. TARGET TORQUE screen is displayed. TARGET TORQUE is target value of fastener. Initial TARGETTORQUE value is value from target torque screen. TARGET TORQUE can be set to any value withinwrench torque range by pressing UP/DOWN buttons. Once desired target torque value has beenset, press ENTER button.

5. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress lights,audible alert and vibrator turn on. Initial MINIMUM TORQUE value is TARGET TORQUE value minusnegative torque tolerance (default 0%, see MODE SETUP in Advanced Configuration section).MINIMUM TORQUE can be set to any value from TARGET TORQUE to wrench minimum torque

ENTER button

Language Selection menu

ENTER button

Decimal Mark Selection menu

ENTER button

held

Target Screen

00

100.0 IN-LB

EXIT SET HEAD LENGTH SHOW DATA

UP/DOWN buttons

ENTER button ENGLISH

FRANCAIS ESPANOL

CLEAR DATA CYCLE COUNT LANGUAGE

ENTER button

DECIMAL MARK COMMA (1,23) POINT (1.23)

UP/DOWN buttons

DECIMAL MARK COMMA (1,23) POINT (1.23)

00

100,0 IN-LB

ENTER button

Preset 1 Torque Screen

Preset 2 Angle Screen

UP/Down buttons

Manual Target Angle Screen

Preset 3 Torque Screen

ENTER button

UP/Down buttons

ENTER button

ENTER button

UP/Down buttons

Manual Target Torque Screen

UP/Down buttons

00

100.0 IN-LB

00

90° PSET 01 03

100.0 IN-LB

PSET 02 04

90°

PSET 03 00

50.0 IN-LB

Page 11: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

10

range by pressing UP/DOWN buttons. Once desired minimum torque value has been set, press ENTER button.

6. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE value plus positive torque tolerance (default 4%, see MODE SETUP in Advanced Configuration section). Maximum torque value can be set greater than TARGET TORQUE value to 10% above wrench maximum range by pressing UP/DOWN buttons. Once desired maximum torque value has been set, press ENTER button.

7. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time target torque is reached if a batch count of zero is entered. Mode Count decrements if a non-zero batch count is entered and resets to batch count value when count reaches zero. Once desired batch count value has been set, press ENTER button.

8. PSET target screen is displayed labeled with next available PSET number from 01 to 50.

9. To enter additional torque presets, repeatedly press ENTER button until target torque screen is displayed and repeat steps above.

Adding an Angle Preset

1. From manual target angle screen, press and hold UNITS button for 3 seconds.

2. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN buttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.

3. TARGET ANGLE screen is displayed. TARGET ANGLE is fastener rotational angle target value. Initial TARGET ANGLE value is value from target angle screen. TARGET ANGLE can be set from 0 to 360° by pressing UP/DOWN buttons. Once desired target angle value has been set, press ENTER button.

4. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is value at which green progress lights, audible alert and vibrator turn on. Initial MINIMUM ANGLE value is TARGET ANGLE minus negative angle tolerance (default 0%, see MODE SETUP in Advanced Configuration section). MINIMUM ANGLE can be set from 0 to TARGET ANGLE by pressing UP/DOWN buttons. Once desired minimum angle value has been set, press ENTER button.

5. MAXMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red progress lights turn on. Initial MAXIMUM ANGLE value will be TARGET ANGLE plus positive angle tolerance (default 4%, see MODE SETUP in Advanced Configuration section). MAXIMUM ANGLE value can be set to any value greater than TARGET ANGLE by pressing UP/DOWN buttons. Once desired value has been set, press ENTER button.

6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time target angle is reached if a batch count of zero is entered. Mode Count decrements if a non-zero batch count is entered and resets to batch count value when count reaches zero. Once desired batch count value has been set, press ENTER button.

7. PSET target screen is displayed labeled with next available PSET number from 01 to 50.

ENTER button ENTER button

UP/DOWN buttons

ENTER button

UNIT button

held

Target Torque Screen UP/DOWN buttons UP/DOWN buttons

ENTER button

ENTER button

UP/DOWN buttons

ENTER button

UP/DOWN buttons Preset Torque Screen

00

100.0 IN-LB

ADD PRESET YES NO

ADD PRESET YES NO

TARGET TORQUE

100.0 IN-LB

MINIMUM TORQUE

100.0 IN-LB

MAXIMUM TORQUE

104.0 IN-LB

BATCH COUNT

3

PSET 01 03

100.0 IN-LB

Page 12: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

11

8. To enter additional angle presets, repeatedly press ENTER button until target angle screen isdisplayed and repeat steps above.

Editing a Preset

Edit PSET function gives user ability to edit stored PSETS on wrench.

1. From Preset screen to be edited, press and hold UNITS button for 3 seconds.

2. CHANGE PRESET screen is displayed.

3. Highlight EDIT selection using UP/DOWN buttons then press ENTER button.

4. TARGET TORQUE or TARGET ANGLE screen is displayed. Value can be changed by pressingUP/DOWN buttons. Once desired target torque or angle value has been set, press ENTER button.

5. MINIMUM TORQUE or MINIMUM ANGLE screen is displayed. Value can be changed by pressingUP/DOWN buttons. Once desired torque or angle value has been set, press ENTER button.

6. MAXMUM TORQUE or MAXMUM ANGLE screen is displayed next. Value can be changed bypressing UP/DOWN buttons. Once desired torque or angle value has been set, press ENTER button.

7. BATCH COUNT screen is displayed next. Value can be changed by pressing UP/DOWN buttons.Once desired batch count value has been set, press ENTER button.

8. PSET target screen is displayed labeled with same PSET number.

Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without editing PSET.

Deleting a Preset

Delete PSET function allows user to remove stored presets from wrench.

1. From Preset screen to be deleted, press and hold UNITS button for 3 seconds.

2. CHANGE PRESET screen is displayed.

3. Highlight DELETE menu selection using UP/DOWN buttons and press ENTER button.

4. Target screen is displayed and deleted PSET is no longer available for selection.

ENTER button ENTER button

UP/DOWN buttons

ENTER button

UNIT button

held

Target Angle Screen UP/DOWN buttons UP/DOWN buttons

ENTER button

ENTER button

UP/DOWN buttons

ENTER button

UP/DOWN buttons Preset Angle Screen

00

90°ADD PRESET

YES NO

ADD PRESET YES

NO

TARGET ANGLE

90°MINIMUM ANGLE

90°

MAXIMUM ANGLE

94°BATCH COUNT

4PSET 02 04

90°

ENTER button ENTER button

UP/DOWN buttons

ENTER button

UNIT button

held

Target Angle Screen UP/DOWN buttons UP/DOWN buttons

ENTER button

ENTER button

UP/DOWN buttons

ENTER button

UP/DOWN buttons Preset Angle Screen

00

90°DELETE

EDIT EXIT

DELETE EDIT EXIT

TARGET ANGLE

92°MINIMUM ANGLE

90°

MAXIMUM ANGLE

94°BATCH COUNT

0PSET 02 00

92°

Page 13: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

12

Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without deleting PSET.

Note: When a PSET is deleted, all other stored PSET’s will retain their original PSET numbers. When a

new PSET is entered, it will be assigned first available PSET number in sequence.

Advanced Settings

Accessing Advanced Settings

Advanced settings are accessed from SETTINGS menu selection on main menu.

1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Highlight SETTINGS menu selection using UP/DOWN buttons.

3. Press ENTER button to display Settings menu.

Menu Selections:

EXIT - Exits Settings menu and returns to target screen.

SHOW INFO - Displays wrench operational information.

SLEEP TIME - Displays power down interval setup screen.

LCD CONTRAST - Displays LCD contrast setup screen.

KEY BEEP - Displays button press beep enable/disable setup screen.

AUTO BACKLIGHT - Displays auto backlight enable/disable screen to turn on backlight during measurement.

TOGGLE BACKLGHT - Displays BACKLIGHT button toggle or timeout enable/disable screen.

VIBRATOR CONFIG - Displays vibrator ON/OFF configuration for when target reached.

BATTERY TYPE – Displays the battery type selection screen.

4. To exit Settings menu and return to target torque or angle screen, press ENTER button while EXIT menu selection is highlighted.

Note: All user configurable settings are stored in non-volatile memory and are retained while power is off.

Show Info

Show Info menu selection displays wrench operational information.

1. From Settings menu, press ENTER button while SHOW INFO selection is highlighted.

2. SHOW INFO screen is displayed.

ENTER button

UNIT button

held

Target Torque Screen

UP/DOWN buttons

ENTER button

Preset Angle Screen

PSET 02 00

92°

DELETE EDIT EXIT

DELETE EDIT EXIT

00

100.0 IN-LB

UP/DOWN buttons

ENTER button

held

Target Screen

ENTER button

00

100.0 IN-LB

EXIT SET HEAD LENGTH SHOW DATA

CYCLE COUNT LANGUAGE SETTINGS

EXIT SHOW INFO SLEEP TIME

Page 14: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

13

3. UP/DOWN buttons are used to scroll screen.

Operational Information:

SN: Serial number assigned to wrench.

CAL: Date of last wrench calibration.

ISD: In-Service Date.

TCF: Torque Calibration Factor.

ACF: Angle Calibration Factor.

VER: Software version.

OVR CNT: Overtorque Counter tracks how many times an over-torque event occurred onwrench (torque >125% of full scale).

TQZ: Torque Zero Offset.

AZZ: Angle Z-Axis Zero Offset.

AXZ: Angle X-axis Zero Offset.

Copyright

4. Pressing ENTER button exits Show Info screen and returns to Settings menu.

Setting Sleep Time

This function will allow user to set interval wrench enters power-down state following last applied torque or button press.

1. From Settings menu, use UP/DOWN buttons to highlight SLEEP TIME selection then press ENTERbutton.

2. SLEEP TIME screen is displayed.

3. Use UP/DOWN buttons to select sleep interval.

Selectable Intervals:

2 MIN (factory default)

5 MIN

10 MIN

30 MIN

1 HR

2 HR

8 HR

4. Press ENTER button to accept selection and exit to Settings menu.

EXIT SHOW INFO SLEEP TIME

SN: 0417500366 CAL: 2017/01/01 ISD: 2017/01/01

ENTER button

UP/DOWN buttons

AXZ: 157 CAL: 2017/01/01 © 2017 SNAP-ON ENTER

button

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

EXIT SHOW INFO SLEEP TIME

SLEEP TIME 2 MIN EXIT

SLEEP TIME 8 HR EXIT

Page 15: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

14

Setting LCD Contrast

This function will allow user to set LCD contrast for optimal viewing.

1. From Settings menu, use UP/DOWN buttons to highlight LCD CONTRAST selection then pressENTER button.

2. CONTRAST screen is displayed.

3. Use UP/DOWN buttons while viewing display to change contrast to desired level.

Selectable levels: 20 to 80 in increments of 5 (factory default = 40).

4. Press ENTER button to accept selection and exit to Settings menu.

Key Beep Setup

This function will allow user to enable or disable audio feedback when a button is pressed.

1. From Settings menu, use UP/DOWN buttons to highlight KEY BEEP selection then press ENTERbutton.

2. KEY BEEP screen is displayed.

3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection.

4. Press ENTER button to accept selection and exit to Settings menu.

Auto Backlight Setup

This function will allow user to enable or disable backlight from turning on during torque or angle measurement.

1. From Settings menu, use UP/DOWN buttons to highlight AUTO BACKLIGHT selection then pressENTER button.

2. AUTO BACKLIGHT screen is displayed.

3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection.

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

SHOW INFO SLEEP TIME LCD CONTRAST

CONTRAST: 20

CONTRAST: 80

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

SLEEP TIME LCD CONTRAST KEY BEEP

KEY BEEP ENABLE DISABLE

KEY BEEP ENABLE DISABLE

Page 16: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

15

4. Press ENTER button to accept selection and exit to Settings menu.

Toggle Backlight Setup

This function will allow user to enable or disable backlight toggle function. If toggle mode is disabled, BACKLIGHT button turns on backlight and it automatically turns off after five seconds following any last button press. If toggle mode is enabled, a BACKLIGHT button press will turn on backlight and it will remain on until next BACKLIGHT button press.

1. From Settings menu, use UP/DOWN buttons to highlight TOGGLE BACKLGHT selection then press ENTER button.

2. TOGGLE BACKLGHT screen is displayed.

3. Use UP/DOWN buttons to highlight ENABLE or DISABLE (factory default) selection.

4. Press ENTER button to accept selection and exit to Settings menu.

Note: Backlight will turn off when wrench powers down either by POWER button press or sleep time.

Note: If toggle backlight is enabled and backlight is on, backlight will remain on during and after applying torque.

Vibrator Configuration

This function will allow user to configure vibrator for On or Off when target is reached for preference and/or battery power savings.

1. From Settings menu, use UP /DOWN buttons to highlight VIBRATOR CONFIG selection then press ENTER button.

2. VIBRATOR CONFIG screen is displayed.

3. Use UP /DOWN buttons to toggle ON or OFF selection.

4. Press ENTER button to accept selection and exit to Settings menu.

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

LCD CONTRAST KEY BEEP AUTO BACKLIGHT

AUTO BACKLIGHT ENABLE DISABLE

AUTO BACKLIGHT ENABLE DISABLE

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

KEY BEEP AUTO BACKLIGHT TOGGLE BCKLGHT

TOGGLE BCKLGHT ENABLE DISABLE

TOGGLE BCKLGHT ENABLE DISABLE

Page 17: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

16

Battery Type Selection

This function will allow user to configure the battery discharge thresholds for the type of battery used.

1. From Settings menu, use UP /DOWN buttons to highlight BATTERY TYPE selection then press ENTER button.

2. BATTERY TYPE screen is displayed.

3. Use UP /DOWN buttons to select the type of battery being used.

4. Press ENTER button to accept selection and exit to Settings menu.

Note: Wrench is configured for Lithium battery shipped from factory. If Lithium battery is replaced with Alkaline or rechargeable Nickel-Metal Hydride (NIMH), battery type should be changed so battery level icon and LOW battery warnings function optimally. Battery life (REPLACE) will not be impacted, however 50% and Low will be optimized to show most accurate linear discharge time.

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

AUTO BACKLIGHT TOGGLE BCKLGHT VIBRATOR CONFIG

VIBRATOR CONFIG ENABLE DISABLE

VIBRATOR CONFIG ENABLE DISABLE

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

EXIT SHOW INFO SLEEP TIME

TOGGLE BCKLGHT VIBRATOR CONFIG BATTERY TYPE

LITHIUM ALKALINE NIMH

LITHIUM ALKALINE NIMH

Page 18: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

17

Advanced Configuration

Accessing Advanced Configuration

Advanced configuration is accessed from CONFIGURE menu selection on main menu.

Note: If wrench has been locked (see Preset Lock and Job Mode), a password entry is required to enter Configure menu.

1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Highlight CONFIGURE menu selection using UP/DOWN buttons.

3. Press ENTER button to display Configure menu.

Menu Selections:

EXIT - Exits Configure menu and returns to target torque or angle screen.

MODE SETUP - Displays wrench mode setup menu.

PRESET LOCK - Displays Preset lock menu.

DELETE PRESETS - Displays delete all presets menu.

JOB MODE - Displays Job mode menu.

CALIBRATION - Displays wrench calibration menu (password protected).

SET DATE/TIME - Displays clock date and time entry screens.

SET CAL INTRVAL - Displays calibration interval setup screen (requires clock date and time setup).

CHANGE PASSWD - Displays change password menu. 4. To exit Configure menu and return to target torque or angle screen, press ENTER button while EXIT

menu selection is highlighted.

Note: All user configurable settings are stored in non-volatile memory and are retained while power is off.

Mode Setup

Mode setup menu allows user configure target torque and angle minus and plus tolerances and enable/disable Torque THEN Angle mode and Torque AND angle mode.

1. From Configure menu, press ENTER button while MODE SETUP selection is highlighted.

2. Mode Setup menu is displayed.

Menu Selections:

EXIT - Exits Mode setup menu and returns to Configure menu screen.

TQ-% SETUP - Displays target torque minus tolerance entry screen.

TQ+% SETUP - Displays target torque plus tolerance entry screen.

ANG-% SETUP - Displays target torque minus tolerance entry screen.

ANG+% SETUP - Displays target torque plus tolerance entry screen.

THEN DISABLED - Displays THEN Mode enable/disable screen.

AND DISABLED - Displays AND Mode enable/disable screen.

3. Use UP/DOWN buttons to highlight menu selections.

4. Press ENTER button while EXIT menu selection is highlighted to return to Configure menu.

EXIT TQ-% SETUP TQ+% SETUP

EXIT MODE SETUPs PRESET LOCK

ENTER button

Configure menu Mode Setup menu

UP/DOWN buttons

ENTER button

held

Target Screen

ENTER button

00

100.0 IN-LB

EXIT SET HEAD LENGTH SHOW DATA

LANGUAGE SETTINGS CONFIGURE

EXIT MODE SETUP PRESET LOCK

Page 19: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

18

Setting Target Tolerances

This function will allow user to set plus and minus tolerances for torque and angle targets.

Note: These tolerances are used for manual modes only. Preset tolerances are defined by Minimum and Maximum values.

1. From Mode Setup menu, use UP/DOWN buttons to highlight tolerance selection to setup (TQ-%,TQ+%, ANG-% ANG+%) then press ENTER button.

2. Tolerance screen is displayed.

3. Use UP/DOWN buttons to change tolerance value. Range is 0 to 10% (factory default for minustolerance is 0% and 4% for plus tolerance).

4. Press ENTER button to accept selection and exit to Mode Setup menu.

Note: Green progress lights turn on at target minus -% TOL.

Note: Red progress lights turn on above target plus +% TOL.

Note: Plus tolerance is added to minimum Preset value to define initial maximum value when a Preset is first added.

Enable/Disable Torque THEN Angle Mode

This function will allow user to enable or disable Torque THEN Mode.

1. From Mode Setup menu, use UP/DOWN buttons to highlight THEN DISABLED (factory default)selection then press ENTER button.

2. TQ THEN ANGLE enable/disable screen is displayed.

3. Use UP/DOWN buttons to select ENABLE or DISABLE selection.

4. Press ENTER button to accept selection and exit to Mode Setup menu.

Note: Menu selection indicates current configuration (ENABLED or DISABLED).

Torque THEN Angle Mode

Torque THEN Angle mode is setup by first setting a target torque and units then a target angle before selecting Torque THEN Angle mode. In Torque THEN Angle mode, when applied torque reaches target torque, wrench automatically switches to angle mode for angle measurement. Progress lights indicate applied torque progress while torque is measured and angle when angle is measured. If torque is below target torque when angle reaches target angle, green progress lights will not turn on and if angle exceeds maximum angle, red progress lights turn on indicating a potential problem with fastener.

ENTER button

TORQUE -TOL%

0 ENTER button

UP/DOWN buttons

EXITTQ-% SETUP TQ+% SETUP

TQ+% SETUPANG-% SETUP ANG+% SETUP

ANGLE +TOL%

4

ENTER button

UP/DOWN buttons

ENTER button

ENTER button

UP/DOWN buttons

EXITTQ-% SETUP TQ+% SETUP

TQ-% SETUPTQ+% SETUP THEN DISABLED

TQ THEN ANGLE ENABLE DISABLE

TQ-% SETUPTQ+% SETUP THEN DISABLED

TQ THEN ANGLE ENABLE DISABLE

TQ-% SETUPTQ+% SETUP THEN ENABLED

Page 20: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

19

1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to selecttorque measurement units then press ENTER button.

2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTERbutton.

3. Torque THEN Angle mode screen is displayed.

4. Apply torque until target is reached then rotate wrench to target angle.

Note: UNITS button can be used to select torque units while on Torque THEN Angle screen.

Note: Torque cycle is not recorded in memory unless both torque and angle reach targets.

Note: Red progress lights turn on if torque exceeds 110% of wrench full scale or if angle exceeds target + plus tolerance while in manual mode.

Note: Torque THEN Angle Presets are entered by pressing and holding Units button while on Torque THEN Angle screen. MAXIMUM TORQUE defaults to full range plus 10%. Refer to "Adding a Torque Preset" and "Adding an Angle Preset" in Basic section for parameter entry.

Enable/Disable Torque AND Angle Mode

This function will allow user to enable or disable Torque AND Mode.

1. From Mode Setup menu, use UP/DOWN buttons to highlight AND DISABLED (factory default)selection then press ENTER button.

2. TQ AND ANGLE enable/disable screen is displayed.

3. Use UP/DOWN buttons to select ENABLE or DISABLE selection.

4. Press ENTER button to accept selection and exit to Mode Setup menu.

Note: Menu selection indicates current configuration (ENABLED or DISABLED).

00

100.0 IN-LB

ENTER button

ENTER button

UP/DOWN buttons

00

45° 00

TQ: 100.0 IN-LB THEN ANG: 45°

UP/DOWN buttons

UP/DOWN buttons

ENTER button

ENTER button

UP/DOWN buttons

EXITTQ-% SETUP TQ+% SETUP

TQ+% SETUPTHEN DISABLED AND DISABLED

TQ AND ANGLE ENABLE DISABLE

TQ+% SETUPTHEN DISABLED AND DISABLED

TQ AND ANGLE ENABLE DISABLE

TQ+% SETUPTHEN DISABLED AND ENABLED

Page 21: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

20

Torque AND Angle Mode

Torque AND Angle mode is setup by first setting a target torque and units then a target angle before selecting Torque AND Angle mode. In Torque AND Angle mode, torque and angle are measured simultaneously. Yellow progress lights track torque measurement. When both torque and angle reach their targets, green progress lights turn on and torque and angle data record is stored. If either of measurements exceed their upper tolerance, red progress lights turn on.

1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to selecttorque measurement units then press ENTER button.

2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTERbutton until Torque AND Angle mode screen is displayed.

3. Apply torque and rotate wrench until both targets are reached.

Note: UNITS button can be used to select torque units while on Torque AND Angle screen.

Note: Torque THEN Angle Presets are entered by pressing and holding Units button while on Torque THEN Angle screen. Refer to "Adding a Torque Preset" and "Adding an Angle Preset" in Basic section for parameter entry.

Note: Torque cycle is not recorded in memory unless both torque and angle reach targets.

Note: Red progress lights turn on if torque exceeds target + plus tolerance or if angle exceeds target + plus tolerance while in manual mode.

Note: Red progress lights turn on if torque exceeds maximum torque or if angle exceeds maximum angle in Preset mode.

Preset Lock

Preset Lock function allows user to lock wrench so that only configured presets are accessible. No other presets can be configured and manual target torque and angle modes are not accessible when locked.

Note: Password entry is required to enable Preset Lock. When locked, password entry is required to re-enter Configure menu (refer to ControlTech™ Micro Calibration manual for default password).

1. From Configure menu, use UP/DOWN buttons to highlight PRESET LOCK selection then pressENTER button.

2. Preset Lock enable/disable screen is displayed.

3. Use UP/DOWN buttons to select LOCK or UNLOCK selection.

4. Press ENTER button to accept selection and exit to Configure menu.

00

100.0 IN-LB

ENTER button

ENTER button

UP/DOWN buttons

00

45° 00

TQ: 100.0 IN-LB AND ANG: 45°

UP/DOWN buttons

ENTER button

EXIT MODE SETUP PRESET LOCK

EXIT MODE SETUP PRESET LOCK

UP/DOWN buttons

ENTER PASSWD

0 0 0 0 0

UP/DOWN buttons

Password screen

ENTER button PRESET LOCK

LOCK UNLOCK

UP/DOWN buttons

PRESET LOCK LOCK UNLOCK

ENTER button

EXIT MODE SETUP PRESET LOCK

Lock icon

PSET 01 03

100.0 IN-LB

EXIT MODE SETUP PRESET LOCK

UP/DOWN buttons

ENTER button

Page 22: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

21

Note: If LOCK is selected without a Preset configured, following screen is displayed:

Note: When Preset Lock is enabled, Clear Memory function is disabled and displays following Locked message if attempted:

Note: When Preset Lock is enabled, Clear Cycle count function is disabled and displays Locked message if attempted.

Preset Unlock

When Preset Lock is enabled, a password is required to access Configure menu. Refer to ControlTech™ Micro Calibration Manual for Configure password.

1. From target torque or angle screen, press and hold ENTER button for 3 seconds.

2. Highlight CONFIGURE menu selection using UP/DOWN buttons.

3. Press ENTER button to display Password screen.

4. Follow password entry procedure found in ControlTech™ Micro Calibration manual.

Delete Presets

Delete Presets function allows user to delete all presets at once.

1. From Configure menu, use UP/DOWN buttons to highlight DELETE PRESET selection then pressENTER button.

2. Delete Presets confirmation screen is displayed.

3. Use UP/DOWN buttons to select YES or NO selection.

4. Press ENTER button to accept selection and exit to Configure menu.

Note: If Delete Presets is selected without a Preset configured, following screen is displayed:

Job Mode

LOCKED PRESS TO CONT.

NO PRESETS

PRESS TOCONT.

NO PRESETS PRESS TO CONT.

UP/DOWN buttons

ENTER button

held

Preset Screen

ENTER button

EXIT SET HEAD LENGTH SHOW DATA

LANGUAGE SETTINGS CONFIGURE

ENTER PASSWD

0 0 0 0 0

PSET 01 03

100.0 IN-LB

UP/DOWN buttons

ENTER button

UP/DOWN buttons

Delete Presets menu

EXIT MODE SETUP PRESET LOCK

MODE SETUP PRESET LOCK DELETE PRESETS

DELETE PRESETS YES NO

Page 23: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

22

Job Mode function allows user to enable or disable wrench preset Job mode. When in Job mode, wrench executes presets in order configured and automatically switches to next preset when batch count reaches zero. Wrench is locked and Preset lock icon is displayed when Job mode is enabled.

Note: Password entry is required to enable Job Mode. When enabled, password entry is required to re-enter Configure menu (refer to ControlTech™ Micro Calibration manual for default password).

1. From Configure menu, use UP/DOWN buttons to highlight JOB MODE selection then press ENTERbutton.

2. Job Mode enable/disable screen is displayed.

3. Use UP/DOWN buttons to select ENABLE or DISABLE.

4. Press ENTER button to accept selection and exit to Configure menu.

Note: Text "JOB" is displayed between PSET number and batch count when enabled.

Calibration

Calibration menu is password protected. Refer to ControlTech™ Micro Calibration manual.

Setting Date and Time

Set Date/Time function allows user to set real-time-clock date and time for time stamping data records, recording last calibration date and notifying user of an expired calibration interval.

Note: When date and time is set for first time, In-Service date is also set and is used for calculating initial calibration interval (see "Setting Calibration Interval" in Advanced Configuration section).

1. From Configure menu, use UP/DOWN buttons to highlight SET DATE/TIME selection then pressENTER button.

2. SET DATE screen is displayed with year highlighted.

3. Use UP/DOWN buttons to set year then press ENTER button to highlight month.

4. Use UP/DOWN buttons to set month then press ENTER button to highlight day.

5. Use UP/DOWN buttons to set day then press ENTER button.

6. SET TIME screen is displayed with hour highlighted.

7. Use UP/DOWN buttons to set hour then press ENTER button to highlight minutes.

8. Use UP/DOWN buttons to set minutes then press ENTER button to highlight seconds.

9. Use UP/DOWN buttons to set seconds then press ENTER button.

10. Clock is set and Configure menu is displayed.

Note: Year selection will scroll up from 2014. Month selection will scroll from 1 to 12. Day selection willscroll from 1 to 31.

ENTER button

EXIT MODE SETUP PRESET LOCK

PRESET LOCK DELETE PRESETS JOB MODE

UP/DOWN buttons

ENTER PASSWD

0 0 0 0 0

UP/DOWN buttons

Password screen

ENTER button JOB MODE

LOCK UNLOCK

UP/DOWN buttons

PRESET LOCK LOCK UNLOCK

ENTER button

PRESET LOCK DELETE PRESETS JOB MODE

Lock icon

PSET 01 JOB 03

100.0 IN-LB

EXIT MODE SETUP PRESET LOCK

UP/DOWN buttons

ENTER button

DELETE PRESETS JOB MODE CALIBRATION

Page 24: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

23

Note: Hour selection will scroll through 0 to 23. Minute and Second selections will scroll through 0 to 59.

Note: If batteries are removed from wrench for longer than 20 minutes, clock will revert to default settings and must be re-entered at power on.

Setting Calibration Interval

This function will allow user to set calibration interval for when "CAL NEEDED" message will be displayed. 1. From Configure menu, use UP/DOWN buttons to highlight SET CAL INTRVAL selection then press

ENTER button.

2. CAL INTERVAL screen is displayed.

3. Use UP/DOWN buttons to change calibration interval.

Selectable Intervals:

12 MON (factory default)

6 MON

3 MON

DISABLED

4. Press ENTER button to accept selection and exit to Configure menu.

Note: Clock Date and Time must be set before calibration interval will function. If batteries are removed from wrench for longer than 20 minutes, clock will revert to default settings and must be re-entered at power on.

Note: Calibration interval is calculated from either IN-Service Date or last Calibration date (see SHOW INFO menu) depending on which is more recent date. When clock Date is greater than IN-Service or Last Calibration date, plus Cal Interval, "CAL NEEDED" message will be displayed on power up and after a re-zero. Pressing ENTER button will continue to target menu. Applying torque while "CAL NEEDED" message is displayed will immediately display torque or angle measurement and return to target menu when released.

Note: As an alternative to calibration interval, a Calibration Cycle Counter is provided in Calibration menu (Refer to ControlTech™ Micro Calibration manual regarding Calibration menu). Each time a measurement cycle reaches target torque, calibration cycle counter is incremented. When

UP/DOWN buttons

ENTER button

ENTER button

ENTER button

UP/DOWN buttons UP/DOWN buttons UP/DOWN buttons

ENTER button

ENTER button

ENTER button

UP/DOWN buttons

ENTER button

UP/DOWN buttons

JOB MODE CALIBRATION SET DATE/TIME

SET DATE 2017/01/01 YR MON DAY

SET DATE 2017/01/01 YR MON DAY

SET DATE 2017/01/01 YR MON DAY

SET TIME 12 : 30 : 00 HR MIN SEC

SET TIME 12 : 30 : 00 HR MIN SEC

SET TIME 12 : 30 : 00 HR MIN SEC

CALIBRATION SET DATE/TIME SET CAL INTRVAL

ENTER button

CAL INTRVAL 12 MON EXIT

UP/DOWN buttons

CAL INTRVAL DISABLED EXIT

ENTER button

Page 25: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

24

torque is recalibrated, calibration counter is automatically reset to zero. User can disable calibration interval check and use number of cycles since last calibration to decide when to recalibrate.

Note: If an invalid date is entered and Calibration interval is enabled, an unintended "CAL NEEDED" message may be displayed. Either disable calibration interval or enter a correct date.

Change Password

Change Password function allows user to change password to a new password. Default password is required to initially change password. Refer to ControlTech™ Micro Calibration Manual for default password.

1. From Configure menu, use UP/DOWN buttons to highlight CHANGE PASSWD selection then pressENTER button.

2. Initial password entry screen is displayed.

3. Enter default password if changing for first time, otherwise enter current user password usingUP/DOWN buttons to change each digit followed by ENTER button.

4. Change password entry screen is displayed.

5. Enter new password using UP/DOWN buttons to change each digit followed by ENTER button.

6. Confirm password entry screen is displayed.

7. Re-enter new password using UP/DOWN buttons to change each digit followed by ENTER button.

Note: Pressing POWER button at any time aborts password change sequence.

Note: If an invalid password is entered during confirmation step, Invalid Password Match screen is displayed and new password is not accepted.

INVALID PASSWD MATCH PRESS TO CONT.

SET DATE/TIME SET CAL INTRVAL CHANGE PASSWD

ENTER PASSWD 0 0 0 0 0

ENTER button

UP/DOWN buttons

ENTER button CHANGE PASSWD

0 0 0 0 0

UP/DOWN buttons

ENTER button

CONFIRM PASSWD 0 0 0 0 0

UP/DOWN buttons

Previous password entry screen New password entry screen Confirm password screen

Page 26: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

25

TroubleshootingNote: If any of following issues persist, return wrench to Daniels Manufacturing Corporation.

Issue Possible Cause Resolution

Wrench does not turn on when POWER button pressed.

Dead/No batteries Replace batteries

Software glitch Cycle power using end-cap

Torque reading out of spec. Calibration required Recalibrate

Incorrect head length entered

Enter correct offset head length

Wrench did not retain settings while batteries were removed.

Batteries removed before setting were saved in non-volatile memory.

Clear data, re-enter settings and press and hold POWER button to power down wrench before removing batteries.

Low battery Press ENTER button to continue using wrench and replace batteries soon.

Dead battery Press POWER button to turn off wrench and replace batteries.

Torque applied while zeroing Remove torque and re-zero

Wrench over torqued Recalibrate

Wrench improperly calibrated

Recalibrate

Torque sensor failure Return to Factory

Wrench moving during zeroing

Place wrench on stable surface

Gyro unstable Return to Factory

ENTER button pressed during angle zeroing (Aborted zeroing to access menus)

Press POWER button to re-zero

Over 125% of full scale torque applied

Cycle power using POWER button and recalibrate

Wrench rotated too fast during angle measurement

Press POWER button to re-zero

Calibration interval exceeded or invalid date entered with calibration interval enabled

Calibrate wrench or press ENTER to continue. Disable calibration interval if not required.

Memory error Clear data memory

Torque uncalibrated Calibrate torque

Angle uncalibrated Calibrate angle

Page 27: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

26

USE OF ADAPTORS, EXTENSIONS AND UNIVERSALSAnytime an adaptor, extension or universal is used with a torque wrench in such a way that fastener distance is different than torque wrench square drive distance at calibration, an adjustment to head length is required to get a proper fastener torque reading.

When using wobble extension or a universal, do not exceed more than 15 degrees of offset from perpendicular drive. Do not use a long extension with flex-drive at full flex.

CALIBRATIONContact your DMC sales representative for calibration services.

CERTIFICATIONThis torque wrench was calibrated at factory using torque measurement instruments that are traceable to National Institute of Standards and Technology (N.I.S.T.). Torque parameters comply with ISO 6789:2003 and ASME B107:300-2010 (B107.29). Note: no U.S. or International Standards exist for angle wrenches. Angle calibration was performed on an angle gage with ±1 degree accuracy at each 45 degree indexing point throughout 180 degrees of rotation.

MAINTENANCE / SERVICEClean wrench by wiping with a damp cloth. DO NOT use solvents, thinners or carburetor cleaners. DO NOT immerse in anything. Service and repairs are to be done by Daniels Manufacturing Corporation only. Contact yourDMC representative.

NOTES: - If display shows persistent "TORQUE ZERO ERROR" at power on, wrench is damaged and must be returned for repair

- If display shows “ANGLE ERROR” in angle mode, fastener rotation speed has exceededcapacity of wrench.

- Wrench must be held still during angle zeroing. Motion is indicated by alternating dashes “--” on display

- Remove battery when stored for extended periods (Note: clock will revert to defaultsettings).

IMPORTANT! Calibration events are recorded in wrench memory which provides evidence to void factory certification.

Page 28: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

27

Battery Replacement

Note: When replacing battery, real-time-clock will maintain date and time for 20 minutes.

Note: Turn End Cap counter-clockwise to unscrew.

Battery should be installed in carrier prior to carrier installation into wrench. Battery negative contact should be oriented towards carrier spring.

Note: When Replace Battery screen is displayed wrench will no longer operate until battery is replaced. Only POWER button functions which immediately turns off wrench.

Memory Indicators

DATA IN MEMORY

MEMORY FULL

MEMORY ERROR

Less than 1500 torque and angle records stored in memory.

1500 torque or angle records stored in memory. New records will not be recorded until memory is cleared.

Memory read or write error.

UNSCREW END CAP INSERT NEW CELL NEGATIVE (-) END INTO END CAP

LOW BATTERY

100% BATTERY LEVEL

50% BATTERY LEVEL

LOW BATTERY

REPLACE BATTERY REPLACE BATTERY

Page 29: BT-ST-302DR - DMCTools...Contact DMC if a translation is needed. 2 Specifications Head Type Square drive 72 teeth, sealed flex and fixed ratchet Fixed 3/8" square drive Reversed Head

Daniels Manufacturing Corporation526 Thorpe Road Orlando, FL 32824 U.S.A. Ph: 407-855-6161Fax: 407-855-6884Email: [email protected]

BT-ST-302DR-DSRevision A1.22.2020

28

DMC offers complete refurbishing and recalibration services.

DMC specially engineers and manufactures complete tool kits to satisfy individual customer requirements, such as total aircraft support general shop maintenance or production, on board ship and vehicle service, etc.

Limitation of Liability

DANIELS MANUFACTURING CORPORATION IS NOT LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE OR KIND RESULTING FROM THE USE, OR MISUSE, OF ANY OF ITS PRODUCTS. OWNERS AND USERS OF DMC PRODUCTS ASSUME FULL RESPONSIBILTY FOR INSTRUCTING THEIR EMPLOYEES IN THE PROPER AND SAFE USE OF SUCH PRODUCTS.

Limited Warranty

DMC (Daniels Manufacturing Corporation) warrants each new product sold by it to be free from defects in material and workmanship under normal use and service. DMC’s obligation under this warranty is limited to the free correction or, at DMC’s option, the refund of the purchase price of any such product which proves defective in normal service within ninety (90) days after delivery to the first user, provided that the product is returned to DMC with all transportation charges prepaid and which shall appear to DMC’s satisfaction, after DMC’s inspection, to have been defective in material and workmanship, it being understood that DMC products are not consumer products. This warranty shall not cover any damage to any product which, in the opinion of DMC, was caused by normal wear, misuse, improper operation, tampering, neglect or accident. This warranty is in lieu of all other warranties express or implied. No warranty, express or implied, is made or authorized to be made or assumed with respect to products of Daniels Manufacturing Corporation other than those herein set forth.