Page 1: Burner Management - Cimarron Energy MANAGEMENT FEATURES • The ARC controller is designed for use with flares, combustors, indirect heaters, treaters, reboilers, and other natural

Bur

ner M

anag

emen

t

Page 2: Burner Management - Cimarron Energy MANAGEMENT FEATURES • The ARC controller is designed for use with flares, combustors, indirect heaters, treaters, reboilers, and other natural

Product OverviewThe Cimarron ARC is a fully scalable BMS that allows

you to only pay for what you need. Need to light and operate

a flare or a combustor? Need full control of multiple line

heaters with temperature, pressure, and level monitoring? No

problem. Upgraded firmware and necessary instrumentation

are available. Whether you’re operating a line heater, treater,

reboiler, flare, combustor, or other natural gas-fired equipment,

the ARC is flexible and provides successful and safe operation

of your equipment.

The ARC provides fully automated direct spark ignition, control of

multiple burners, temperature and pressure monitoring, Modbus

RS-485 communication, and on-board data logging. Modbus

RS-485 and 4-20mA input are standard features at no additional

cost. The ARC is exceptional in its low power consumption,

an important feature that minimizes the cost if solar power

packages are required.

Installation is simple, and the exterior keypad on the NEMA 4X

enclosure allows user-friendly control of the menus and settings.

The display is a four-line organic light emitting diode (OLED),

providing information on status and menu options. A Quick

Response Code (QR) on the front of the enclosure allows you

to access and download documentation on your smart device

whenever you need help.

The ARC was designed by Cimarron Energy, a leading

manufacturer of upstream and midstream solutions for oil and

gas operators. We understand what is required in operating your

equipment. The product is also manufactured, assembled, and

tested by Cimarron Energy at its facilities in Colorado, providing

total quality control over every unit.

BURNER MANAGEMENT

FEATURES• The ARC controller is designed for use with flares, combustors,

indirect heaters, treaters, reboilers, and other natural gas fired equipment commonly used in the oil and gas production segment

• Fully automated direct spark ignition

• Control of both pilot and main burners

• Customer PLC compatibility with Modbus RTU over RS-485 communication protocol (standard)

• On-board data logging and time stamping with event logging of up to two years with 4 megabytes of internal storage

• 12 / 24 VDC compatible

• I/O for temperature, pressure and valve control

SPECIFICATIONS• Class 1, Division 2, Groups ABCD, Pending

• NEMA 4X Polycarbonate Enclosure

• -40°F to 140°F (-40°C to 60°C)

• RS-485 ports with Modbus RTU

• 4-20mA input (4-20mA output available)

• Large 4x20 OLED display

• Multi-function tactile keypad

• Dimensions: 10” x 12” x 6”

• 12 / 24 VDC compatible

• Outputs: (2) latch valves or up to (4) solenoid valve outputs; (1) general purpose digital output; (1) alarm output; (1) flexible auxiliary I/O

• Inputs: (3) thermocouple inputs, (4) general purpose digital inputs, and (1) pressure transducer input

Page 3: Burner Management - Cimarron Energy MANAGEMENT FEATURES • The ARC controller is designed for use with flares, combustors, indirect heaters, treaters, reboilers, and other natural

Cimarron provides other accessories that may be needed to operate fired equipment.

These can be ordered with the ARC or at your convenience.

PRODUCTCONFIGURATOR

N - Non-classified areaC - C1D2 Compliant

AREA CLASSIFICATIONAREA

APPLICATION1 - Enclosed Combustor2 - Single Production Unit3 - Dual Production Unit4 - Heater Treater5 - Dehy/Amine Reboiler6 - Line Heater

APPLICATION

VALVE 1 (Pilot ValVe)0 - Valve Not Required1 - 1/4″ 0.55W Valve2 - 3-Wire Latch Valve

VALVE 1

VALVE 2 (Main Burner)0 - Valve Not Required1 - 1/4″ 0.55W Valve2 - 3-Wire Latch Valve3 - 1″ 2W Valve

VALVE 2SYSTEM POWER0 - 12VDC Available On-Site1 - 24VDC Available On-Site2 - AC Power Available On-Site3 - Power Package Required

SYSTEM POWER

TEMPERATURE MONITOR 10 - Thermocouple Not Required1 - 6″ Type K Thermocouple w/ Thermowell2 - 12″ Type K Thermocouple w/ Thermowell

TEMPERATURE 1

TEMPERATURE MONITOR 20 - Thermocouple Not Required1 - 6″ Type K Thermocouple w/ Thermowell2 - 12″ Type K Thermocouple w/ Thermowell

TEMPERATURE 2

PRESSURE MONITORING0 - Transducer Not Required1 - 0-5 PSI Transducer2 - 0-30 PSI Transducer3 - 0-100 PSI Transducer4 - 0-500 PSI Transducer

PRESSURE MONITORING

1 2 3 4 5 6 7 8

ACCESSORIES

BURNER MANAGEMENT

• Cimarron inline pilot assembly and cabling

• Flameco pilot assembly and cabling

• Replacement parts kit

• Power package 1: 5W solar panel and battery backup

• Power package 2: 20W solar panel and battery backup

• Customized fuel train packages

• AC/DC power converters

• Additional I/O ca be added using DIN rail mounted expansion modules

• 4-20mA output module

• Supply gas scrubber, 10” x 19”

Page 4: Burner Management - Cimarron Energy MANAGEMENT FEATURES • The ARC controller is designed for use with flares, combustors, indirect heaters, treaters, reboilers, and other natural

Sales and ServiceDenver, COBerthold, NDWilliston, NDOklahoma City, OKHouston, TXMidland, TXPittsburgh, PAIndiana, PAVernal, UTCharleston, WVCasper, WY

ManufacturingGrafton, NDEvans, COEnglewood, CONorman, OKMarlow, OKKaty, TX

ContactSales 405-928-7373

[email protected]

CimarronEnergy.com