NEK 606-2004,IEC 60092-350,IEC 60092-351,IEC 60092-352,IEC 60092-353,IEC 60092-354,IEC 60092-359,IEC 60092-375,IEC 60092-376,IEC 60228,IEC 60331-11/12/21/25/31,IEC 60332-1/3,IEC 60446,IEC 60754-1/2,IEC 60811,IEC 61034-1/2,Mud Résistant,Résistance à l’huile,Résistance Au Feu,Ignifugation,Hydrocarbures (HCF) résistant au feu,Émission de fumée,Contenu de l’halogène,Résistance conducteur,Notes de court-circuit,Réactance,Impédance,Identification de base

TRANSCRIPT

Page 1: Caledonian Câbles Offshore & Marine NORME NEK606

Caledonian Câbles Offshore & Marine

NORME NEK606

www.caledonian-cables.co.ukwww.caledonian-cables.fr

Caledonian

ROYAUME-UNI

Marchants Centre industriel,Mill Lane, Laughton, Lewes,East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]

HONG KONG

Unité B 22 / F CMA bâtiment,64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]

Copyright@ Caledonian Câbles Offshore & Marine

Page 2: Caledonian Câbles Offshore & Marine NORME NEK606

Caledonian, créé en 1978, offre l'une des gammes les plus complètes de solutions de fibres et de systèmes de câblage cuivre avec plus de centaines de produits différents systèmes de câblage. Nos produits de qualité supérieure fournissent pointe au sein de chaque série du câble et pour chaque application.

Parmi les normes nationales et internationales avec lesquelles nos câbles pourraient se conformer sont: BS - British Standard; LPCB incendie Performance Standard, la norme ISO etc. Câbles Caledonian propose un stock complet de câbles et de produits de câblage à travers son réseau national de revendeurs et de distributeurs. Câbles calédoniens a continuellement élargi sa présence internationale en Europe et en Asie.

Caledonian & Addison, produit une large gamme de câbles de communication, la puissance et l'électronique dans ses usines primaires au Royaume-Uni, Italie et Espagne. Pour rester à l'avant, nous gardons toujours l'expansion de nos capacités de fabrication dans plusieurs régions à faible coût tels que la Roumanie, Taiwan, la Malaisie, etc. Ce faible coût des installations de fabrication nous permettent de fournir un système global souple, évolutive qui offre une performance opérationnelle supérieure et des résultats optimaux pour nos clients.

Notre vaste réseau mondial d'installations de fabrication nous donne grande échelle et la flexibilité pour répondre à nos exigences du client. Cette présence mondiale fournit des solutions de conception et de conseil qui sont combinés avec la fabrication de câble de base, les services logistiques, et verticalement intégrés avec nos technologies de commerce électronique, afin d'optimiser les opérations des clients en réduisant les coûts et en réduisant les délais de commercialisation.

Caledonian & Addison a été respecté pour ses normes élevées de qualité, un excellent niveau de service, des prix compétitifs et un esprit unique et novateur. Avec nos dernières technologies, nous sommes à la fois inspirés et bien positionnés pour répondre aux besoins changeants de nos clients. Nous avons les ressources pour diversifier et de renforcer nos lignes de produits et services. Nous comprenons le besoin de changement et avec notre planification précise, nous sommes prêts pour l'avenir et la promesse de nouvelles possibilités de commercialisation. Notre tradition de la croissance grâce à l'excellence est assurée.

Nos centres de conception travaillent en étroite collaboration avec les clients afin d'améliorer constamment sa gamme standard de produits et de technologies et de développer sur mesure, des pays et des solutions spécifiques à l'industrie. Caledonian & Addison a établi un vaste réseau de conception, de fabrication, et de logistique dans les principaux marchés du monde pour répondre aux besoins d'externalisation croissants des clients multinationaux et régionaux.

Copyright@ Caledonian Câbles Offshore & Marine

Page 3: Caledonian Câbles Offshore & Marine NORME NEK606

1ADDISONwww.addison-cables.com

P1 ou P1/P8 RFOU/TFOU 0.6/1KV ......................................................................3P18 RU 0.6/1kV ....................................................................................................8P15 UX 0.6/1kV ..................................................................................................12

CONTENU

Moyenne Tension Câbles D’alimentation

Puissance De Feu Résistant Et Câbles De Commande

Résistant Au Feu Moyenne Tension Câbles

Câbles Instrumentation

P5 ou P5/P12 BFOU 0.6/1KV .............................................................................14P17 BU 0.6/1 kV .................................................................................................19P34 BFOU-HCF 0.6/1 kV ....................................................................................23

P2 ou P2/P9 RFOU/TFOU 3.6/6KV ...................................................................26P3 ou P3/P10 RFOU/TFOU 6/10KV ...................................................................29P4 ou P4/P11 RFOU/TFOU 8.7/15KV ................................................................32P19 ou P19/P21 RFOU 12/20KV ........................................................................35

P6 ou P6/P13 BFOU 3.6/6kV .............................................................................38P7 ou P7/P14 BFOU 6/10kV .............................................................................41P30 RFOU-HCF / TFOU-HCF 6/10(12) kV .........................................................44

S1 ou S1/S5 RFOU(i) 250V ................................................................................47S2 ou S2/S6 RFOU(c) 250V ...............................................................................53P16 IFLI 250 V ...................................................................................................59S11 RU(i) 250 V ..................................................................................................61S12 RU(c) 250 V .................................................................................................64

Résistant Au Feu Instrumentation Câbles

S3 ou S3/S7 BFOU(i) 250V ................................................................................67S4 ou S4/S8 BFOU(c) 250V ...............................................................................73S13 BU(i) 250 V .................................................................................................79

Pouvoir Et De Contrôle CâblesCopyright@

Caledonian Câbles Offshore & Marine

Page 4: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

2 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG6 Câble Coaxial Blindé ................................................................................105RG11 Câble Coaxial Blindé ..............................................................................107RG59 Câble Coaxial Blindé ..............................................................................109RG58 Câble Coaxial Blindé .............................................................................. 111RG213 Câble Coaxial Blindé ............................................................................ 113Câble Composite résistant à la boue ................................................................ 115

Câbles De Télécommunications

Câbles De Données

Câbles Coaxiaux

S9 IYXI(c) 60 V ...................................................................................................89S10 IYOI(c) 60 V .................................................................................................91

S14 BU(c) 250 V ................................................................................................82S15 BFOU-HCF(i) 250 V ...................................................................................85S16 BFOU-HCF(c) 250 V ..................................................................................87

F1 QFCI .............................................................................................................93F5 QFCB ............................................................................................................95F6 AICI ...............................................................................................................97

Cat5E UTP/FTP Blindé câble de données .........................................................99Cat6 UTP/FTP Blindé câble de données ..........................................................102

Cable Code Désignation ................................................................................... 117Normes et Tests .... ........................................................................................... 118Caractéristiques du câble ................................................................................ 119Des données électriques ..................................................................................121Identification de base .......................................................................................123

Informations Techniques

Câbles Fibre Optique

Copyright@ Caledonian Câbles Offshore & Marine

Page 5: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

3ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P1 ou P1/P8 RFOU/TFOU 0.6/1KV

Applications

Câbles marines sont ignifuge, sans fumée, halogène gratuits résistant à la boue, utilisé pour les systèmes d'éclairage de contrôle et de puissance.

Normes

IEC 60092-353 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs : Étamé recuite cuivre multibrins IEC 60228 classe 2. Isolation: Sans halogène EPR. XLPE peut être proposé en option (pour le câble

TFOU) Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Sans halogène composés thermodurcissables, SHF2 (de TYPE

P1). Halogène gratuit, résistant à la boue thermodurcissable composé, boue de la SHF (de TYPE P1/P8), de couleur noire.

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5 2.5 4 6 10 16 25 35 50 70Chef d’orchestre Diamètre nominal mm 1.6 2.1 2.6 3.2 4.0 5.1 6.5 7.4 8.7 10.3Resistant@20℃ DC maximale Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391 0.27

Fil De Cuivre Ètamé

Halogène Gratuit Isolation EPR/XLPE

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2/SHF Gaine De Boue

Copyright@ Caledonian Câbles Offshore & Marine

Page 6: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

4 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Courant Nominal Continu@45℃ 1 Core A 23 30 40 52 72 96 127 157 196 242

Courant Nominal Continu@45℃ 2 Core A 20 26 34 44 61 82 108 133 167 206

Courant Nominal Continu@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 137 169

1s courant de court circuit A 210 360 570 860 1430 2290 3580 5010 7150 10020Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Cross Section Nominale Zone mm² 95 120 150 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 12.2 13.8 15.1 17.0 19.6 21.9 24.6 27.6 32.5Resistant@20℃ DC maximale Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 293 339 389 444 522 601 690 780 890Courant Nominal Continu@45℃ 2 Core A 249 288 331 444 444 511 587 663 757Courant Nominal Continu@45℃ 3&4 Core A 205 237 272 311 365 421 483 546 623

1s courant de court circuit A 13590 17170 21460 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Remarque : Pour plus de 4 cœurs, les notations actuelles peuvent être calculées par la formule ,I1= L a note actuelle pendant 1-coeure, N = Nombre de conducteurs.

Facteurs de Correction de la température ambianteFacteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids Construction

de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×1.5 1.0 1.1 1.1 8.9 1351×2.5 1.0 1.1 1.1 9.3 1501×4 1.0 1.1 1.1 9.9 1801×6 1.0 1.1 1.1 10.4 2051×10 1.0 1.1 1.2 12.2 2951×16 1.0 1.1 1.2 13.5 385

Copyright@ Caledonian Câbles Offshore & Marine

Page 7: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

5ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×25 1.2 1.1 1.2 15.4 5251×35 1.2 1.1 1.3 16.9 6851×50 1.4 1.1 1.4 18.7 8701×70 1.4 1.1 1.4 20.4 11051×95 1.6 1.1 1.5 22.8 14351×120 1.6 1.2 1.6 24.9 17451×150 1.8 1.2 1.6 26.8 20551×185 2.0 1.2 1.7 29.3 25601×240 2.2 1.2 1.8 32.5 31901×300 2.4 1.2 1.9 35.2 39351×400 2.4 1.4 2.1 40.5 50601×500 2.4 1.4 2.2 44.0 61801×630 2.4 1.4 2.3 48.0 76202×1.5 1.0 1.1 1.2 13.6 2952×2.5 1.0 1.1 1.2 14.4 3352×4 1.0 1.1 1.3 16.1 4452×6 1.0 1.1 1.3 17.1 5202×10 1.0 1.1 1.4 19.3 6802×16 1.0 1.1 1.5 21.7 9552×25 1.2 1.2 1.6 25.9 13352×35 1.2 1.2 1.7 27.9 15952×50 1.4 1.2 1.9 31.9 22502×70 1.4 1.2 2.1 35.8 27952×95 1.6 1.2 2.3 41.2 37802×120 1.6 1.4 2.4 44.8 45602×150 1.8 1.4 2.6 49.2 55002×185 2.0 1.4 2.7 53.8 66752×240 2.2 1.6 3.0 61.0 86052×300 2.4 1.6 3.2 67.0 105103×1.5 1.0 1.1 1.2 14.2 3203×2.5 1.0 1.1 1.3 15.6 4153×4 1.0 1.1 1.3 16.8 5003×6 1.0 1.1 1.4 18.1 6053×10 1.0 1.1 1.4 20.3 7953×16 1.0 1.1 1.5 22.8 11253×25 1.2 1.2 1.6 27.5 16203×35 1.2 1.2 1.7 29.6 19553×50 1.4 1.2 1.9 33.9 27303×70 1.4 1.4 2.0 38.4 36553×95 1.6 1.4 2.2 43.8 4885

Copyright@ Caledonian Câbles Offshore & Marine

Page 8: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

6 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

3×120 1.6 1.4 2.3 47.6 60003×150 1.8 1.6 2.5 52.4 73003×185 2.0 1.6 2.7 58.6 89603×240 2.2 1.8 2.9 66.1 116103×300 2.2 1.8 3.4 71.9 134904×1.5 1.0 1.1 1.3 15.7 3504×2.5 1.0 1.1 1.3 16.6 4254×4 1.0 1.1 1.4 18.1 5904×6 1.0 1.1 1.4 19.5 7254×10 1.0 1.1 1.5 22.1 9554×16 1.0 1.2 1.6 25.2 13754×25 1.2 1.2 1.7 30.0 19654×35 1.2 1.2 1.8 32.4 24104×50 1.4 1.4 2.0 37.3 33654×70 1.4 1.4 2.2 42.1 45804×95 1.6 1.4 2.4 48.2 6020

4×120 1.6 1.6 2.5 52.7 74404×150 1.8 1.6 2.9 58.3 88004×185 2.0 1.6 3.1 64.0 107604×240 2.2 1.8 3.4 72.4 138904×300 2.4 1.8 3.7 79.8 174055×1.5 1.0 1.1 1.3 16.7 4206×1.5 1.0 1.1 1.3 17.8 4957×1.5 1.0 1.1 1.3 17.8 5408×1.5 1.0 1.1 1.5 20.3 6459×1.5 1.0 1.1 1.5 21.5 67510×1.5 1.0 1.1 1.5 21.8 70512×1.5 1.0 1.1 1.5 22.5 80514×1.5 1.0 1.1 1.6 23.6 86016×1.5 1.0 1.1 1.7 24.9 94019×1.5 1.0 1.1 1.7 26.0 110020×1.5 1.0 1.1 1.7 27.2 113023×1.5 1.0 1.1 1.8 29.3 128524×1.5 1.0 1.1 1.8 30.0 130527×1.5 1.0 1.1 1.9 30.8 146030×1.5 1.0 1.1 1.9 31.8 152033×1.5 1.0 1.2 2.0 33.5 167037×1.5 1.0 1.2 2.0 34.6 184044×1.5 1.0 1.2 2.2 39.2 22105×2.5 1.0 1.1 1.4 18.0 555

Copyright@ Caledonian Câbles Offshore & Marine

Page 9: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

7ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

6×2.5 1.0 1.1 1.4 19.2 5907×2.5 1.0 1.1 1.4 19.2 6558×2.5 1.0 1.1 1.5 21.8 7759×2.5 1.0 1.1 1.6 23.3 78510×2.5 1.0 1.1 1.6 23.6 86512×2.5 1.0 1.1 1.6 24.5 95514×2.5 1.0 1.1 1.7 25.5 107016×2.5 1.0 1.1 1.7 26.7 115519×2.5 1.0 1.1 1.8 28.2 136020×2.5 1.0 1.1 1.8 29.5 141023×2.5 1.0 1.1 1.9 31.8 161024×2.5 1.0 1.2 2.0 33.2 169027×2.5 1.0 1.2 2.0 33.9 181530×2.5 1.0 1.2 2.0 34.9 196033×2.5 1.0 1.2 2.1 36.7 219037×2.5 1.0 1.2 2.1 38.0 237044×2.5 1.0 1.2 2.3 42.6 2795

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 10: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

8 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P18 RU 0.6/1kV

Applications

Ces câbles sont ignifuge, sans fumée, halogène gratuits résistant à la boue, utilisé pour les systèmes d'éclairage de contrôle et de puissance.

Normes

IEC 60092-353 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Étamé recuite cuivre multibrins IEC 60228 classe 2. Isolation: Sans halogène EPR. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2, de couleur

noire.

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5 2.5 4 6 10 16 25 35Chef d’orchestre Diamètre nominal mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Resistant@20℃ DC maximale Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Courant Nominal Continu@45℃ 1 Core A 23 30 40 52 72 96 127 157Courant Nominal Continu@45℃ 2 Core A 20 26 34 44 61 82 108 133Courant Nominal Continu@45℃ 3&4 Core A 16 21 28 36 50 67 89 110

1s courant de court circuit A 210 360 570 860 1430 2290 3580 5010Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Isolation EPR Gratuit Halogène

Conducteur En Cuivre Multibrins

SHF2 Gaine

Copyright@ Caledonian Câbles Offshore & Marine

Page 11: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

9ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Cross Section Nominale Zone mm² 50 70 95 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Resistant@20℃ DC maximale Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Courant Nominal Continu@45℃ 1 Core A 196 242 293 339 389 444 522 601Courant Nominal Continu@45℃ 2 Core A 167 206 249 288 331 444 444 511Courant Nominal Continu@45℃ 3&4 Core A 137 169 205 237 272 311 365 4211s courant de court circuit A 7150 10020 13590 17170 21460 26470 34340 42930Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Remarque : Pour plus de 4 cœurs, les notations actuelles peuvent être calculées par la formule , I1= La note actuelle pendant 1-coeure, N = Nombre de conducteurs.

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1×1.5 1.0 1.0 6.0 601×2.5 1.0 1.0 6.5 801×4 1.0 1.0 7.1 1101×6 1.0 1.0 7.6 1301×10 1.0 1.1 8.5 1651×16 1.0 1.1 9.8 2351×25 1.2 1.2 11.7 3551×35 1.2 1.2 12.8 4551×50 1.4 1.3 14.4 5951×70 1.4 1.4 16.3 8051×95 1.6 1.5 18.7 10901×120 1.6 1.5 20.3 13451×150 1.8 1.6 22.4 16351×185 2.0 1.7 24.9 2075

Copyright@ Caledonian Câbles Offshore & Marine

Page 12: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

10 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1×240 2.2 1.8 28.1 26601×300 2.4 1.9 30.8 33402×1.5 1.0 1.1 9.7 1452×2.5 1.0 1.1 10.5 1752×4 1.0 1.2 11.6 2252×6 1.0 1.2 12.9 2952×10 1.0 1.3 14.8 4202×16 1.0 1.4 17.2 6052×25 1.2 1.5 21.3 9402×35 1.2 1.6 23.3 11852×50 1.4 1.8 26.9 15852×70 1.4 1.9 31.9 22802×95 1.6 2.1 36.9 30902×120 1.6 2.2 40.3 37802×150 1.8 2.4 44.7 46402×185 2.0 2.6 49.5 57502×240 2.2 2.8 56.1 74602×300 2.4 3.0 62.0 92653×1.5 1.0 1.1 10.3 1653×2.5 1.0 1.2 11.1 2053×4 1.0 1.2 12.5 2803×6 1.0 1.3 13.6 3603×10 1.0 1.3 16.0 5303×16 1.0 1.4 18.5 7703×25 1.2 1.6 22.9 12003×35 1.2 1.7 25.0 15253×50 1.4 1.8 28.7 20303×70 1.4 2.0 32.6 27653×95 1.6 2.2 37.6 37453×120 1.6 2.3 41.2 46403×150 1.8 2.5 45.7 56753×185 2.0 2.7 51.2 72003×240 2.2 3.0 57.5 93003×300 2.4 3.2 66.8 120804×1.5 1.0 1.2 11.2 2004×2.5 1.0 1.2 12.4 2554×4 1.0 1.3 13.7 3404×6 1.0 1.3 15.2 4554×10 1.0 1.4 17.5 6654×16 1.0 1.5 20.4 9704×25 1.2 1.7 25.5 15304×35 1.2 1.8 27.8 19554×50 1.4 2.0 31.9 2600

Copyright@ Caledonian Câbles Offshore & Marine

Page 13: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

11ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

4×70 1.4 2.1 36.3 35404×95 1.6 2.4 42.0 48154×120 1.6 2.5 46.0 59654×150 1.8 2.7 53.5 77204×185 2.0 2.9 59.2 95704×240 2.2 3.2 67.3 124804×300 2.4 3.5 74.6 158705×1.5 1.0 1.2 13.1 2456×1.5 1.0 1.3 14.4 2757×1.5 1.0 1.3 14.4 2858×1.5 1.0 1.4 16.9 3809×1.5 1.0 1.4 18.1 39510×1.5 1.0 1.4 18.4 43512×1.5 1.0 1.4 19.0 48514×1.5 1.0 1.5 20.2 56516×1.5 1.0 1.5 21.3 61519×1.5 1.0 1.6 22.6 71520×1.5 1.0 1.6 23.8 78023×1.5 1.0 1.7 25.9 90524×1.5 1.0 1.7 26.6 92027×1.5 1.0 1.7 27.2 98530×1.5 1.0 1.8 28.4 111033×1.5 1.0 1.8 29.5 119037×1.5 1.0 1.9 30.8 131544×1.5 1.0 2.0 34.8 15605×2.5 1.0 1.3 14.3 3056×2.5 1.0 1.3 15.6 3607×2.5 1.0 1.3 15.6 3908×2.5 1.0 1.4 18.4 4959×2.5 1.0 1.5 19.9 50510×2.5 1.0 1.5 20.2 57012×2.5 1.0 1.5 20.9 62514×2.5 1.0 1.5 21.9 73516×2.5 1.0 1.6 23.3 81019×2.5 1.0 1.6 24.6 93520×2.5 1.0 1.7 26.1 103523×2.5 1.0 1.8 28.4 120524×2.5 1.0 1.8 29.2 122027×2.5 1.0 1.8 29.9 129530×2.5 1.0 1.9 31.1 147533×2.5 1.0 1.9 32.3 158537×2.5 1.0 2.0 33.8 173044×2.5 1.0 2.2 38.4 2100

Copyright@ Caledonian Câbles Offshore & Marine

Page 14: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

12 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P15 UX 0.6/1kV

Applications

Ces câbles sont ignifuge, sans fumée et halogènes, utilisé pour la mise à la terre et les services de liaison.

Normes

IEC 60092-353 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Tresse cuivre multibrins recuit à la CEI 60228 classe 2 ou classe 5. Isolation: Composé de thermodurcissable, SHF2 sans halogène. Lorsqu’il est utilisé

comme fil conducteur de protection (PE), les câbles de couleur jaune/vert. Lorsqu’il est utilisé comme seul fil, les câbles de couleur blanc cassé, noir, rouge ou bleu.

Caractéristiques électriques

Cross Section Nominale Zone mm² 10 16 25 35 50 70Chef d’orchestre Diamètre nominal mm 4 5.1 6.5 7.4 8.7 10.3Resistant@20℃ DC maximale Ω/km 1.84 1.16 0.734 0.529 0.391 0.27Courant nominal continu@45℃ 1 Coeur A 72 96 127 157 196 2421s courant de court circuit A 1430 2290 3580 5010 7150 10020Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Cross Section Nominale Zone mm² 95 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 12.2 13.8 15.1 17.0 19.6 21.9

SHF2 Isolation

Conducteur En Cuivre Multibrins

Copyright@ Caledonian Câbles Offshore & Marine

Page 15: Caledonian Câbles Offshore & Marine NORME NEK606

Power and Control Cables

13ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Resistant@20℃ DC maximale Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607Courant nominal continu@45℃ 1 Coeur A 293 339 389 444 522 6011s courant de court circuit A 13590 17170 21460 26470 34340 42930Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×10 2.0 8.2 160

1×16 2.1 9.4 230

1×25 2.4 11.3 350

1×35 2.4 12.4 450

1×50 2.7 14.4 600

1×70 3.0 16.7 840

1×95 3.0 18.6 1110

1×120 3.1 20.3 1360

1×150 3.4 22.4 1660

1×185 3.7 24.9 2080

1×240 4.0 28.1 2690

1×300 4.3 31.0 3330

Copyright@ Caledonian Câbles Offshore & Marine

Page 16: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

14 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P5 ou P5/P12 BFOU 0.6/1KV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour les systèmes de contrôle, de puissance et d'éclairage.

Normes

IEC 60092-353 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Étamé recuit échoué cuivre compacté à la norme IEC 60228 classe 2.. Isolation: Ruban Mica + Halogène EPR libre/Ruban Mica + XLPE. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Sans halogène composés thermodurcissables, SHF2 (pour TYPE

P5). Halogène gratuit, résistant à la boue thermodurcissable composé, boue de la SHF (de TYPE P5/P12), de couleur noire.

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5 2.5 4 6 10 16 25 35 50Chef d’orchestre Diamètre nominal mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4 8.7Resistant@20℃ DC maximale Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391

Fil De Cuivre Ètamé

Bande De Mica + HFEPR/XLPE Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUE

Copyright@ Caledonian Câbles Offshore & Marine

Page 17: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

15ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Courant Nominal Continu@45℃ 1 Core A 23 30 40 52 72 96 127 157 196Courant Nominal Continu@45℃ 2 Core A 20 26 34 44 61 82 108 133 167Courant Nominal Continu@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 1371s courant de court circuit A 210 360 570 860 1430 2290 3580 5010 7150Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Cross Section Nominale Zone mm² 70 95 120 150 185 240 300 400 630

Chef d’orchestre Diamètre nominal mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9 24.6 32.5

Resistant@20℃ DC maximale Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0286

Courant Nominal Continu@45℃ 1 Core A 242 293 339 389 444 522 601 690 890Courant Nominal Continu@45℃ 2 Core A 206 249 288 331 444 444 511 587 757Courant Nominal Continu@45℃ 3&4 Core A 169 205 237 272 311 365 421 483 623

1s courant de court circuit A 10020 13590 17170 21460 26470 34340 42930 57230 90140Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Remarque : Pour plus de 4 cœurs, les notations actuelles peuvent être calculées par la formule , I1= La note actuelle pendant 1-coeure, N = Nombre de conducteurs.

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×1.5 1.0 1.1 1.1 9.3 1451×2.5 1.0 1.1 1.1 9.7 1601×4 1.0 1.1 1.1 10.4 2201×6 1.0 1.1 1.1 10.9 2501×10 1.0 1.1 1.2 12.7 310

Copyright@ Caledonian Câbles Offshore & Marine

Page 18: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

16 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×16 1.0 1.1 1.2 13.9 3901×25 1.2 1.1 1.3 16.3 5851×35 1.2 1.1 1.3 17.2 6901×50 1.4 1.1 1.4 19.0 8901×70 1.4 1.1 1.4 20.6 11101×95 1.6 1.1 1.5 23.1 14401×120 1.6 1.2 1.6 25.0 17351×150 1.8 1.2 1.7 27.0 20601×185 2.0 1.2 1.7 29.4 25451×240 2.2 1.2 1.8 32.6 31701×300 2.4 1.2 1.9 35.3 39101×400 2.4 1.4 2.1 41.0 51001×630 2.8 1.4 2.3 48.5 76602×1.5 1.0 1.1 1.2 14.2 3102×2.5 1.0 1.1 1.3 15.1 3602×4 1.0 1.1 1.3 16.6 4702×6 1.0 1.1 1.4 17.9 5552×10 1.0 1.1 1.4 19.9 7052×16 1.0 1.1 1.5 22.5 9852×25 1.2 1.2 1.6 26.4 13602×35 1.2 1.2 1.7 28.4 16202×50 1.4 1.2 1.9 32.4 22902×70 1.4 1.2 2.1 38.0 32602×95 1.6 1.2 2.3 41.6 39102×120 1.6 1.4 2.4 45.3 47102×150 1.8 1.4 2.6 49.7 56702×185 2.0 1.4 2.7 54.3 68402×240 2.2 1.6 3.0 61.5 87902×300 2.4 1.6 3.2 67.8 106303×1.5 1.0 1.1 1.3 14.8 3453×2.5 1.0 1.1 1.3 16.2 4453×4 1.0 1.1 1.3 17.4 5303×6 1.0 1.1 1.4 18.7 6353×10 1.0 1.1 1.5 21.1 8303×16 1.0 1.1 1.5 23.7 11603×25 1.2 1.2 1.7 28.1 16403×35 1.2 1.2 1.8 30.2 19803×50 1.4 1.2 2.0 34.3 27503×70 1.4 1.2 2.2 39.0 36753×95 1.6 1.4 2.4 44.7 4955

Copyright@ Caledonian Câbles Offshore & Marine

Page 19: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

17ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

3×120 1.6 1.4 2.5 48.3 60353×150 1.8 1.4 2.7 53.2 73553×185 2.0 1.6 2.9 59.5 90253×240 2.2 1.6 3.2 66.5 115903×300 2.4 1.8 3.4 72.6 137404×1.5 1.0 1.1 1.3 16.4 4004×2.5 1.0 1.1 1.3 17.3 5054×4 1.0 1.1 1.4 18.8 6204×6 1.0 1.1 1.4 20.1 7504×10 1.0 1.1 1.5 22.7 9854×16 1.0 1.2 1.6 25.9 14004×25 1.2 1.2 1.8 30.7 19954×35 1.2 1.2 1.9 33.1 24404×50 1.4 1.4 2.0 38.2 34304×70 1.4 1.4 2.2 42.7 46004×95 1.6 1.6 2.4 49.4 61354×120 1.6 1.6 2.5 53.6 75154×150 1.8 1.6 2.9 59.0 90104×185 2.0 1.6 3.1 64.7 110004×240 2.2 1.8 3.4 73.1 141604×300 2.4 1.8 3.7 80.7 175505×1.5 1.0 1.1 1.4 17.7 5106×1.5 1.0 1.1 1.4 19.0 5457×1.5 1.0 1.1 1.4 19.0 5908×1.5 1.0 1.1 1.5 21.8 7159×1.5 1.0 1.1 1.6 23.3 72010×1.5 1.0 1.1 1.6 23.6 79012×1.5 1.0 1.2 1.6 24.3 88014×1.5 1.0 1.2 1.7 25.5 96516×1.5 1.0 1.2 1.7 26.7 103519×1.5 1.0 1.2 1.7 27.4 118520×1.5 1.0 1.2 1.8 29.5 126023×1.5 1.0 1.2 1.9 31.8 143524×1.5 1.0 1.2 2.0 33.2 151027×1.5 1.0 1.2 2.0 33.9 161530×1.5 1.0 1.2 2.0 34.9 173532×1.5 1.0 1.4 2.0 35.5 180033×1.5 1.0 1.4 2.0 36.7 194037×1.5 1.0 1.4 2.0 38.0 209044×1.5 1.0 1.4 2.3 42.6 2460

Copyright@ Caledonian Câbles Offshore & Marine

Page 20: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

18 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

5×2.5 1.0 1.1 1.4 18.8 5956×2.5 1.0 1.1 1.4 20.4 6507×2.5 1.0 1.1 1.4 20.4 7008×2.5 1.0 1.1 1.5 23.5 7909×2.5 1.0 1.1 1.6 25.1 86010×2.5 1.0 1.1 1.6 25.4 95512×2.5 1.0 1.2 1.6 26.1 104514×2.5 1.0 1.2 1.7 27.3 116016×2.5 1.0 1.2 1.8 28.8 126519×2.5 1.0 1.2 1.8 29.6 144520×2.5 1.0 1.2 1.9 31.8 154523×2.5 1.0 1.4 2.0 34.7 180524×2.5 1.0 1.4 2.0 35.8 185027×2.5 1.0 1.4 2.0 35.4 197030×2.5 1.0 1.4 2.1 38.1 223533×2.5 1.0 1.4 2.2 39.6 239037×2.5 1.0 1.4 2.3 41.2 261044×2.5 1.0 1.4 2.4 46.2 3075

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 21: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

19ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P17 BU 0.6/1 kV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les systèmes de contrôle, de puissance et d'éclairage.

Normes

IEC 60092-353 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-2 NEK 606:2004

Construction

Conducteurs: Étamé recuite cuivre multibrins IEC 60228 classe 2. Isolation: Ruban Mica + Halogène EPR libre. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2, de couleur

noire.

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5 2.5 4 6 10 16 25 35Chef d’orchestre Diamètre nominal mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Resistant@20℃ DC maximale Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Courant Nominal Continu@45℃ 1 Core A 23 30 40 52 72 96 127 157Courant Nominal Continu@45℃ 2 Core A 20 26 34 44 61 82 108 133Courant Nominal Continu@45℃ 3&4 Core A 16 21 28 36 50 67 89 110

Ruban Mica + HFEPR Isolation

Conducteur En Cuivre Multibrins

SHF2 Gaine

Copyright@ Caledonian Câbles Offshore & Marine

Page 22: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

20 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

1s courant de court circuit A 210 360 570 860 1430 2290 3580 5010Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Cross Section Nominale Zone mm² 50 70 95 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Resistant@20℃ DC maximale Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Courant Nominal Continu@45℃ 1 Core A 196 242 293 339 389 444 522 601Courant Nominal Continu@45℃ 2 Core A 167 206 249 288 331 444 444 511Courant Nominal Continu@45℃ 3&4 Core A 137 169 205 237 272 311 365 4211s courant de court circuit A 7150 10020 13590 17170 21460 26470 34340 42930Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Remarque : Pour plus de 4 cœurs, les notations actuelles peuvent être calculées par la formule , I1= La note actuelle pendant 1-coeure, N = Nombre de conducteurs.

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1×1.5 1.0 1.0 6.4 651×2.5 1.0 1.0 6.8 751×4 1.0 1.0 7.4 951×6 1.0 1.0 7.9 1201×10 1.0 1.1 8.8 1701×16 1.0 1.1 10.2 2401×25 1.2 1.2 12.0 3601×35 1.2 1.2 13.1 4551×50 1.4 1.3 14.7 6001×70 1.4 1.4 16.6 8051×95 1.6 1.5 19.0 10951×120 1.6 1.5 20.6 1345

Copyright@ Caledonian Câbles Offshore & Marine

Page 23: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

21ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1×150 1.8 1.6 22.7 16351×185 2.0 1.7 25.2 20701×240 2.2 1.8 28.4 26551×300 2.4 1.9 31.1 33352×1.5 1.0 1.1 10.3 1552×2.5 1.0 1.2 11.0 1902×4 1.0 1.2 12.3 2502×6 1.0 1.3 13.4 3102×10 1.0 1.3 15.6 4452×16 1.0 1.4 18.2 6352×25 1.2 1.6 22.0 9702×35 1.2 1.7 24.0 12152×50 1.4 1.8 27.4 16152×70 1.4 1.9 32.6 23352×95 1.6 2.1 37.6 31552×120 1.6 2.3 41.2 38752×150 1.8 2.4 45.4 47252×185 2.0 2.6 50.2 58452×240 2.2 2.8 56.8 75702×300 2.4 3.1 63.0 93953×1.5 1.0 1.2 10.9 1803×2.5 1.0 1.2 11.9 2303×4 1.0 1.2 13.1 2953×6 1.0 1.3 14.2 3753×10 1.0 1.4 16.5 5503×16 1.0 1.5 19.3 7953×25 1.2 1.6 23.5 12203×35 1.2 1.7 25.6 15453×50 1.4 1.9 29.5 20753×70 1.4 2.0 33.2 27753×95 1.6 2.2 38.5 38003×120 1.6 2.4 42.0 46853×150 1.8 2.5 46.3 56853×185 2.0 2.7 51.8 72153×240 2.2 3.0 58.0 93203×300 2.4 3.2 67.6 122804×1.5 1.0 1.2 12.1 2254×2.5 1.0 1.2 13.0 2754×4 1.0 1.3 14.5 3654×6 1.0 1.4 15.8 4904×10 1.0 1.4 18.4 6954×16 1.0 1.5 21.5 10054×25 1.2 1.7 26.1 15504×35 1.2 1.8 28.5 1970

Copyright@ Caledonian Câbles Offshore & Marine

Page 24: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

22 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des carottes × coupe

transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

4×50 1.4 2.0 32.8 26454×70 1.4 2.2 36.9 35454×95 1.6 2.4 42.8 48504×120 1.6 2.6 46.5 59654×150 1.8 2.8 54.6 80204×185 2.0 3.0 60.3 99304×240 2.2 3.3 68.4 129204×300 2.4 3.5 75.5 159955×1.5 1.0 1.3 14.3 2656×1.5 1.0 1.3 15.6 3057×1.5 1.0 1.3 15.6 3208×1.5 1.0 1.4 18.4 4259×1.5 1.0 1.5 19.9 44010×1.5 1.0 1.5 20.2 49512×1.5 1.0 1.5 20.9 53014×1.5 1.0 1.6 21.9 63016×1.5 1.0 1.6 23.3 69019×1.5 1.0 1.6 24.6 79020×1.5 1.0 1.7 26.1 88023×1.5 1.0 1.8 28.4 103024×1.5 1.0 1.8 29.2 103527×1.5 1.0 1.8 29.9 108030×1.5 1.0 1.9 31.1 125033×1.5 1.0 1.9 32.3 133537×1.5 1.0 2.0 33.8 144544×1.5 1.0 2.2 38.4 17655×2.5 1.0 1.3 14.5 3406×2.5 1.0 1.4 17.0 3957×2.5 1.0 1.4 17.0 4208×2.5 1.0 1.5 20.0 5359×2.5 1.0 1.5 21.5 56010×2.5 1.0 1.5 21.8 62012×2.5 1.0 1.6 22.7 68014×2.5 1.0 1.6 23.9 81016×2.5 1.0 1.7 25.4 89519×2.5 1.0 1.7 26.8 100020×2.5 1.0 1.8 28.4 114023×2.5 1.0 1.9 30.9 132524×2.5 1.0 1.9 31.8 134027×2.5 1.0 1.9 32.5 139530×2.5 1.0 2.0 33.9 162033×2.5 1.0 2.0 35.2 173537×2.5 1.0 2.1 36.8 186544×2.5 1.0 2.3 41.8 2295

Copyright@ Caledonian Câbles Offshore & Marine

Page 25: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

23ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P34 BFOU-HCF 0.6/1 kV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les systèmes de contrôle d'urgence, alimentation et d'éclairage qui doivent être opérationnels pendant un feu d'hydrocarbures 1100 ℃.

Normes

IEC 60092-353 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Étamé recuit échoué cuivre compacté à la norme IEC 60228 classe 2.. Isolation: Ruban Mica + Halogène EPR libre/XLPE. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure1: Halogène composé thermodurcissable libre, SHF2. HC-Protection Contre L’incendie: Extruded thermoplastic fire protection compound. Enregistrement :Ruban de fibre de verre rodé. Gaine extérieure2: Ignifuge sans halogène thermoplastique composé, SHF1, couleur

noir. .

SHF2 Gaine

Ruban Mica + HFEPR/XLPE IsolationLiterie Sans Halogène

Conducteur En Cuivre Multibrins

SHF1 Gaine

HC-Protection Contre L'incendie+Ruban AdhésifFil De Cuivre Ètamé

Copyright@ Caledonian Câbles Offshore & Marine

Page 26: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

24 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5 2.5 4 6 16 35Chef d’orchestre Diamètre nominal mm 1.6 2.1 2.6 3.2 5.1 7.4Resistant@20℃ DC maximale Ω/km 12.2 7.56 4.7 3.11 1.16 0.529Courant Nominal Continu@45℃ 1 Core A 23 30 40 52 96 157Courant Nominal Continu@45℃ 2 Core A 20 26 34 44 82 133Courant Nominal Continu@45℃ 3&4 Core A 16 21 28 36 67 1101s courant de court circuit A 210 360 570 860 2290 5010Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Cross Section Nominale Zone mm² 50 70 95 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Resistant@20℃ DC maximale Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Courant Nominal Continu@45℃ 1 Core A 196 242 293 339 389 444 522 601Courant Nominal Continu@45℃ 2 Core A 167 206 249 288 331 444 444 511Courant Nominal Continu@45℃ 3&4 Core A 137 169 205 237 272 311 365 4211s courant de court circuit A 7150 10020 13590 17170 21460 26470 34340 42930Tension de fonctionnement KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Remarque : Pour plus de 4 cœurs, les notations actuelles peuvent être calculées par la formule , I1= La note actuelle pendant 1-coeure, N = Nombre de conducteurs.

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 12×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Copyright@ Caledonian Câbles Offshore & Marine

Page 27: Caledonian Câbles Offshore & Marine NORME NEK606

Puissance De Feu Résistant Et Câbles De Commande

25ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal cours Literie

mm

Diamètre nominal sur gaine1

mm

Diamètre nominal global mm

Poids nominalkg/km

1×50 1.4 15.0 18.5 45.5 29001×70 1.4 16.5 20.5 47.5 33001×95 1.6 18.5 23.0 50.5 38001×120 1.6 20.5 25.0 52.5 42601×150 1.8 23.0 27.0 54.5 47501×185 2.0 25.0 29.5 57.5 53801×240 2.2 28.0 32.5 66.0 70501×300 2.4 30.5 35.5 68.0 80002×1.5 1.0 10.0 13.0 40.5 18902×2.5 1.0 11.0 14.5 42.0 20803×1.5 1.0 10.5 14.0 42.0 21403×2.5 1.0 11.5 15.0 42.5 22003×4 1.0 13.0 16.5 43.0 24003×6 1.0 14.0 18.0 45.0 26003×16 1.0 18.5 23.0 50.0 35003×35 1.2 25.0 29.5 57.5 48403×70 1.4 33.0 39.0 72.0 81503×120 1.6 41.0 48.0 81.5 113003×150 1.8 46.0 54.5 88.5 133004×2.5 1.0 12.5 16.5 44.0 23004×6 1.0 15.5 19.5 47.5 28704×16 1.0 20.5 25.0 53.5 38307×1.5 1.0 14.0 17.5 44.5 255012×1.5 1.0 18.5 22.5 50.0 314027×1.5 1.0 26.5 31.0 64.5 50707×2.5 1.0 15.0 19.0 46.0 276012×2.5 1.0 20.5 24.5 52.0 3500

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 28: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

26 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P2 ou P2/P9 RFOU/TFOU 3.6/6KV

Applications

Ces câbles sont ignifuges, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Sans halogène EPR. XLPE peut être proposé en option (pour le câble

TFOU). Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P2), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P2/P9), de couleur rouge.

Caractéristiques électriques

Cross Section Nominale Zone mm² 16 25 35 50 70 95 120

Fil De Cuivre Ètamé

HFEPR/XLPE Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 29: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

27ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Chef d'orchestre Diamètre nominal mm 5.1 6.5 7.4 8.7 10.3 12.2 13.8Resistant@20℃ DC maximale Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Courant Nominal Continu@45℃ 1 Core A 96 127 157 196 242 293 339Courant Nominal Continu@45℃ 3 Core A 67 89 110 137 169 205 2371s courant de court circuit A 2290 3580 5010 7150 10020 13590 17170Tension de fonctionnement KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Cross Section Nominale Zone mm² 150 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 15.1 17.0 19.6 21.9 24.6 27.6 32.5Resistant@20℃ DC maximale Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 389 444 522 601 690 780 890Courant Nominal Continu@45℃ 3 Core A 272 311 365 421 483 546 6231s courant de court circuit A 21460 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante

35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×16 2.5 1.4 1.1 22.8 7801×25 2.5 1.5 1.1 24.0 10201×35 2.5 1.5 1.2 25.1 11551×50 2.5 1.6 1.2 26.3 13201×70 2.5 1.6 1.3 28.2 15951×95 2.5 1.7 1.3 30.0 1905

Copyright@ Caledonian Câbles Offshore & Marine

Page 30: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

28 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×120 2.5 1.8 1.4 31.8 22351×150 2.5 1.8 1.4 33.5 25501×185 2.5 1.9 1.5 35.4 30151×240 2.6 2.0 1.5 38.8 37251×300 2.8 2.1 1.6 42.3 46251×400 3.0 2.2 1.7 46.6 54201×500 3.2 2.4 1.8 50.8 66101×630 3.2 2.5 1.9 55.1 81703×16 2.5 2.2 1.6 44.9 29303×25 2.5 2.3 1.7 45.4 33903×35 2.5 2.4 1.8 47.6 38203×50 2.5 2.5 1.9 50.9 44953×70 2.5 2.7 2.0 54.8 55853×95 2.5 2.8 2.1 58.9 67653×120 2.5 3.0 2.2 63.5 81653×150 2.5 3.1 2.3 67.4 94953×185 2.5 3.3 2.4 75.8 106603×240 2.6 3.5 2.5 82.3 116603×300 2.8 3.8 2.7 89.3 12940

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 31: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

29ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P3 ou P3/P10 RFOU/TFOU 6/10KV

Applications

Ces câbles sont ignifuges, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Sans halogène EPR. XLPE peut être proposé en option (pour le câble

TFOU). Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P3), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P3/P10), de couleur rouge.

Caractéristiques électriques

Cross Section Nominale Zone mm² 16 25 35 50 70 95 120

Fil De Cuivre Ètamé

HFEPR/XLPE Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 32: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

30 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Chef d’orchestre Diamètre nominal mm 5.2 6.5 7.4 8.7 10.3 12.2 13.8Resistant@20℃ DC maximale Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Courant Nominal Continu@45℃ 1 Core A 96 127 157 196 242 293 339Courant Nominal Continu@45℃ 3 Core A 67 89 110 137 169 205 2371s courant de court circuit A 2290 3580 5010 7150 10020 13590 17170Tension de fonctionnement KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Cross Section Nominale Zone mm² 150 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Resistant@20℃ DC maximale Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 389 444 522 601 690 780 890Courant Nominal Continu@45℃ 3 Core A 272 311 365 421 483 546 6231s courant de court circuit A 21460 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Facteurs de Correction de la température ambianteFacteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×16 3.4 1.5 1.1 24.0 9001×25 3.4 1.5 1.2 26.0 11401×35 3.4 1.6 1.2 26.9 12651×50 3.4 1.6 1.2 28.3 14601×70 3.4 1.7 1.3 30.0 17101×95 3.4 1.8 1.3 32.0 20601×120 3.4 1.8 1.4 33.8 23801×150 3.4 1.9 1.4 35.3 27001×185 3.4 2.0 1.5 37.8 3225

Copyright@ Caledonian Câbles Offshore & Marine

Page 33: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

31ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×240 3.4 2.1 1.6 41.0 39901×300 3.4 2.2 1.6 43.7 47601×400 3.4 2.3 1.7 45.5 59001×500 3.4 2.4 1.8 49.5 73501×630 3.4 2.6 1.9 54.5 87503×16 3.4 2.3 1.7 46.0 33003×25 3.4 2.4 1.8 50.1 39053×35 3.4 2.5 1.8 52.2 43603×50 3.4 2.6 1.9 55.1 51853×70 3.4 2.7 2.0 58.9 61253×95 3.4 2.9 2.1 63.5 75003×120 3.4 3.0 2.2 67.6 87753×150 3.4 3.2 2.3 71.7 102353×185 3.4 3.4 2.4 74.0 113003×240 3.4 3.6 2.6 79.5 133003×300 3.4 3.8 2.7 85.0 16300

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 34: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

32 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P4 ou P4/P11 RFOU/TFOU 8.7/15KV

Applications

Ces câbles sont ignifuges, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Sans halogène EPR. XLPE peut être proposé en option (pour le câble

TFOU). Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P4), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P4/P11), de couleur rouge.

Caractéristiques électriques

Cross Section Nominale Zone mm² 25 35 50 70 95 120

Fil De Cuivre Ètamé

HFEPR/XLPE Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 35: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

33ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Chef d’orchestre Diamètre nominal mm 6.5 7.4 8.7 10.3 12.2 13.8Resistant@20℃ DC maximale Ω/km 0.734 0.529 0.391 0.27 0.195 0.154Courant Nominal Continu@45℃ 1 Core A 127 157 196 242 293 339Courant Nominal Continu@45℃ 3 Core A 89 110 137 169 205 2371s courant de court circuit A 3580 5010 7150 10020 13590 17170Tension de fonctionnement KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15

Cross Section Nominale Zone mm² 150 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Resistant@20℃ DC maximale Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 389 444 522 601 690 780 890Courant Nominal Continu@45℃ 3 Core A 272 311 365 421 483 546 6231s courant de court circuit A 21460 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur1×25 4.5 1.6 1.2 28.4 13051×35 4.5 1.6 1.3 29.3 14301×50 4.5 1.7 1.3 30.7 16201×70 4.5 1.8 1.3 32.4 19001×95 4.5 1.8 1.4 34.4 22501×120 4.5 1.9 1.5 36.6 26251×150 4.5 2.0 1.5 38.1 2940

Copyright@ Caledonian Câbles Offshore & Marine

Page 36: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

34 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur1×185 4.5 2.0 1.5 40.6 35451×240 4.5 2.1 1.6 43.4 42201×300 4.5 2.2 1.7 46.3 50701×400 4.5 2.4 1.8 50.2 57601×500 4.5 2.5 1.8 53.6 68801×630 4.5 2.6 1.9 57.9 84603×25 4.5 2.6 1.9 55.3 47253×35 4.5 2.7 2.0 57.5 52153×50 4.5 2.8 2.0 60.6 59603×70 4.5 2.9 2.1 64.4 70353×95 4.5 3.1 2.2 68.7 83703×120 4.5 3.2 2.3 72.7 97453×150 4.5 3.4 2.4 76.8 111403×185 4.5 3.6 2.6 84.2 134903×240 4.5 3.8 2.7 90.6 158603×300 4.5 4.0 2.9 96.6 18320

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 37: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

35ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P19 ou P19/P21 RFOU 12/20KV

Applications

Ces câbles sont ignifuges, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Sans halogène EPR. XLPE peut être proposé en option (pour le câble

TFOU). Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P19), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P19/P21), de couleur rouge.

Facultatif

P20 ou P20/P22 RFOU/TFOU 18/30(36) kV

Fil De Cuivre Ètamé

HFEPR/XLPE Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 38: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

36 ADDISON www.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 16 25 35 50 70 95Chef d’orchestre Diamètre nominal mm 5.2 6.5 7.4 8.7 10.3 12.2Resistant@20℃ DC maximale Ω/km 1.16 0.734 0.529 0.391 0.27 0.195Courant Nominal Continu@45℃ 1 Core A 96 127 157 196 242 293Courant Nominal Continu@45℃ 3 Core A 67 89 110 137 169 2051s courant de court circuit A 2290 3580 5010 7150 10020 13590Tension de fonctionnement KV 12/20 12/20 12/20 12/20 12/20 12/20

Cross Section Nominale Zone mm² 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 13.8 15.1 17.0 19.6 21.9Resistant@20℃ DC maximale Ω/km 0.154 0.126 0.1 0.0762 0.0607Courant Nominal Continu@45℃ 1 Core A 339 389 444 522 601Courant Nominal Continu@45℃ 3 Core A 237 272 311 365 4211s courant de court circuit A 17170 21460 26470 34340 42930Tension de fonctionnement KV 12/20 12/20 12/20 12/20 12/20

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur1×16 5.5 1.4 1.2 28 12001×25 5.5 1.5 1.2 31.6 15301×35 5.5 1.8 1.3 32.3 1595

Copyright@ Caledonian Câbles Offshore & Marine

Page 39: Caledonian Câbles Offshore & Marine NORME NEK606

Moyenne Tension Câbles D'alimentation

37ADDISONwww.addison-cables.com

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur1×50 5.5 1.8 1.4 33.8 17951×70 5.5 1.9 1.4 34.6 20701×95 5.5 2.0 1.5 37.0 24701×120 5.5 2.0 1.5 38.8 28101×150 5.5 2.1 1.6 40.7 32451×185 5.5 2.2 1.6 42.9 37651×240 5.5 2.3 1.7 45.8 45101×300 5.5 2.4 1.8 48.5 53153×16 5.5 1.8 2.0 55.5 49503×25 5.5 1.9 2.0 62.2 57053×35 5.5 2.9 2.1 62.6 59903×50 5.5 3.0 2.2 65.4 67403×70 5.5 3.1 2.3 69.1 77903×95 5.5 3.3 2.4 73.0 91503×120 5.5 3.4 2.5 77.4 105803×150 5.5 3.6 2.6 81.9 121453×185 5.5 3.8 2.7 89.5 122653×240 5.5 4.0 2.9 96.1 147253×300 5.5 4.2 3.0 101.9 17190

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 40: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

38 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P6 ou P6/P13 BFOU 3.6/6kV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Ruban Mica + Halogène EPR libre. Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P6), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P6/P13), de couleur rouge.

Fil De Cuivre Ètamé

Ruban Mica + HFEPR Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF MUD Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 41: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

39ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 25 35 50 70 95 120 150Chef d’orchestre Diamètre nominal mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Resistant@20℃ DC maximale Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Courant Nominal Continu@45℃ 1 Core A 127 157 196 242 293 339 389Courant Nominal Continu@45℃ 3 Core A 89 110 137 169 205 237 2721s courant de court circuit A 3580 5010 7150 10020 13590 17170 21460Tension de fonctionnement KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Cross Section Nominale Zone mm² 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 17.0 19.6 21.9 24.5 27.5 32.3Resistant@20℃ DC maximale Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 444 522 601 690 780 890Courant Nominal Continu@45℃ 3 Core A 311 365 421 483 546 6231s courant de court circuit A 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 3.6/6 3.6/6 3.6/6 8.7/15 8.7/15 8.7/15

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×16 2.5 1.5 1.2 24.8 9501×25 2.5 1.6 1.2 26.3 1110

Copyright@ Caledonian Câbles Offshore & Marine

Page 42: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

40 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×35 2.5 1.6 1.2 27.6 12601×50 2.5 1.7 1.3 29.1 14601×70 2.5 1.7 1.3 30.9 17401×95 2.5 1.8 1.4 33.2 21101×120 2.5 1.9 1.4 34.9 24301×150 2.5 1.9 1.4 36.9 28901×185 2.5 2.0 1.5 39.1 33701×240 2.6 2.1 1.6 42.2 41001×300 2.8 2.2 1.6 44.7 48101×400 3.0 2.3 1.7 48.1 58101×500 3.2 2.5 1.8 52.1 70301×630 3.2 2.6 1.9 56.5 86303×16 2.5 2.3 1.7 48.2 35503×25 2.5 2.5 1.8 51.5 41803×35 2.5 2.6 1.9 54.7 48203×50 2.5 2.7 1.9 57.4 54903×70 2.5 2.8 2.0 61.6 65903×95 2.5 3.0 2.1 66.2 79203×120 2.5 3.1 2.2 70.1 91503×150 2.5 3.3 2.3 74.0 104603×185 2.5 3.4 2.4 78.6 120103×240 2.6 3.7 2.6 86.3 146903×300 2.8 3.9 2.8 92.3 17130

Copyright@ Caledonian Câbles Offshore & Marine

Page 43: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

41ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P7 ou P7/P14 BFOU 6/10kV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour l'installation fixe pour moyenne tension.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Ruban Mica + Halogène EPR libre. Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

P7), ou un halogène boue sans composé thermodurcissable résistant, SHF MUD (pour le TYPE P7/P14), de couleur rouge.

Fil De Cuivre Ètamé

Ruban Mica + HFEPR Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF MUD Gaine De BOUEÉcran D’isolationÉcran Du Conducteur

Copyright@ Caledonian Câbles Offshore & Marine

Page 44: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

42 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 25 35 50 70 95 120 150Chef d’orchestre Diamètre nominal mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Resistant@20℃ DC maximale Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Courant Nominal Continu@45℃ 1 Core A 127 157 196 242 293 339 389Courant Nominal Continu@45℃ 3 Core A 89 110 137 169 205 237 2721s courant de court circuit A 3580 5010 7150 10020 13590 17170 21460Tension de fonctionnement KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Cross Section Nominale Zone mm² 185 240 300 400 500 630Chef d’orchestre Diamètre nominal mm 17.0 19.6 21.9 24.5 27.5 32.3Resistant@20℃ DC maximale Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Courant Nominal Continu@45℃ 1 Core A 444 522 601 690 780 890Courant Nominal Continu@45℃ 3 Core A 311 365 421 483 546 6231s courant de court circuit A 26470 34340 42930 57230 71540 90140Tension de fonctionnement KV 6/10 6/10 6/10 8.7/15 8.7/15 8.7/15

Facteurs de Correction de la température ambiante

Facteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD (lors de l’installation); 9×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×16 3.4 1.5 1.2 25.6 9901×25 3.4 1.6 1.2 27.1 1150

Copyright@ Caledonian Câbles Offshore & Marine

Page 45: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

43ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×35 3.4 1.7 1.2 28.5 13201×50 3.4 1.7 1.3 29.9 15001×70 3.4 1.8 1.3 31.9 18101×95 3.4 1.8 1.4 34.0 21601×120 3.4 1.9 1.4 36.1 26101×150 3.4 2.0 1.5 38.1 29901×185 3.4 2.0 1.5 39.9 34401×240 3.4 2.2 1.6 43.1 41801×300 3.4 2.3 1.7 45.9 49301×400 3.4 2.4 1.7 49.0 59001×500 3.4 2.5 1.8 52.5 70701×630 3.4 2.7 1.9 57.0 86903×16 3.4 2.4 1.8 50.2 37803×25 3.4 2.5 1.8 53.2 43803×35 3.4 2.6 1.9 56.4 50403×50 3.4 2.7 2.0 59.3 57403×70 3.4 2.9 2.1 63.7 69003×95 3.4 3.1 2.2 68.4 82703×120 3.4 3.2 2.3 72.1 94703×150 3.4 3.3 2.4 76.0 108003×185 3.4 3.5 2.5 80.8 123703×240 3.4 3.7 2.7 88.2 150403×300 3.4 3.9 2.9 94.0 17450

Copyright@ Caledonian Câbles Offshore & Marine

Page 46: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

44 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les systèmes de contrôle d'urgence, alimentation et d'éclairage qui doivent être opérationnels pendant un feu d'hydrocarbures 1100 ℃.

Normes

IEC 60092-354 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Circulaire cuivre recuit étamé brin CEI 60228 classe 2. Écran du conducteur: Semi en matériau conducteur. Isolation: Sans halogène EPR. XLPE peut être proposé en option. Écran d’isolation: Semi matériau conducteur et étamé tresse de fils de cuivre. Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure1: Halogène composé thermodurcissable libre, SHF2, de couleur

rouge. Protection contre l’incendie-HC :Protection contre l’incendie thermoplastique

composé des profilés extrudés.. Enregistrement :Ruban de fibre de verre rodé.

Fil De Cuivre Ètamé

HFEPR/XLPE Isolation

Literie Sans HalogèneConducteur En Cuivre Multibrins

SHF2 GaineÉcran D’isolationÉcran Du Conducteur

SHF1 Gaine

HC-Protection Contre L'incendie+Ruban Adhésif

Copyright@ Caledonian Câbles Offshore & Marine

Page 47: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

45ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Gaine extérieure2: Ignifuge sans halogène thermoplastique composé, SHF1, de couleur rouge..

Facultatif

P31 RFOU-HCF / TFOU-HCF 8.7/15kVP32 RFOU-HCF / TFOU-HCF 12/20(24) kVP33 RFOU-HCF / TFOU-HCF 18/30(36) kV

Caractéristiques électriques

Cross Section Nominale Zone mm² 70 95 120 150 185 240 300Chef d’orchestre Diamètre nominal mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9Resistant@20℃ DC maximale Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Courant Nominal Continu@45℃ 1 Core A 242 293 339 389 444 522 601Courant Nominal Continu@45℃ 3 Core A 169 205 237 272 311 365 4211s courant de court circuit A 10020 13590 17170 21460 26470 34340 42930Tension de fonctionnement KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Facteurs de Correction de la température ambianteFacteurs de Correction de la température ambiante 35 40 45 50 55 60 65 70 75 80

Facteur Note 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 12×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal cours Literie

mm

Diamètre nominal sur gaine1

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×70 3.4 23.5 30.0 62.0 52201×95 3.4 25.5 32.0 64.5 59001×120 3.4 27.5 34.0 66.5 63401×150 3.4 28.5 35.0 67.5 6670

Copyright@ Caledonian Câbles Offshore & Marine

Page 48: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Moyenne Tension Câbles

46 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des

carottes × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal cours Literie

mm

Diamètre nominal sur gaine1

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×185 3.4 30.5 36.5 69.0 73201×240 3.4 33.0 39.0 72.0 82501×300 3.4 35.0 41.5 74.5 92803×50 3.4 47.0 55.0 89.0 109703×95 3.4 54.0 62.5 97.0 14230

3×150 3.4 60.0 70.5 106.0 17400

Remarque : Pour un câble XLPE isolé, une mince épaisseur de l'isolation est appliquée.

Copyright@ Caledonian Câbles Offshore & Marine

Page 49: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

47ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S1 ou S1/S5 RFOU(i) 250V

Applications

Ces câbles sont ignifuge, sans fumée, halogènes libres et résistant à la boue, util isé pour l ' instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Blindage individuel : Chaque paires/triples sont examinées par ruban de polyester

soutenue en cuivre en contact avec un fil de drain en cuivre étamé toronné et enveloppé avec du ruban adhésif polyester. Couples/triples sont numérotés avec un ruban numéroté ou par numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

S1). Gratuit composé thermodurcissable résistant à la boue halogène, boue de la SHF (pour TYPE S1/S5), de couleur gris (bleu pour sécurité intrinsèque).

Fil De Cuivre Ètamé

HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUE

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 50: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

48 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×2×0.75 0.6 1.1 1.1 10.9 2102×2×0.75 0.6 1.1 1.3 13.2 3254×2×0.75 0.6 1.1 1.3 16.2 4807×2×0.75 0.6 1.1 1.4 19.0 6708×2×0.75 0.6 1.1 1.4 20.4 7559×2×0.75 0.6 1.1 1.5 22.6 83510×2×0.75 0.6 1.1 1.5 23.5 87512×2×0.75 0.6 1.1 1.5 24.1 101014×2×0.75 0.6 1.1 1.6 25.3 104015×2×0.75 0.6 1.1 1.6 26.9 112016×2×0.75 0.6 1.1 1.6 27.3 116518×2×0.75 0.6 1.1 1.7 28.7 127019×2×0.75 0.6 1.1 1.7 29.0 136020×2×0.75 0.6 1.1 1.7 30.1 142021×2×0.75 0.6 1.1 1.8 31.0 149023×2×0.75 0.6 1.1 1.8 31.5 159524×2×0.75 0.6 1.2 1.8 33.4 172027×2×0.75 0.6 1.2 1.9 34.0 177030×2×0.75 0.6 1.2 1.9 35.1 1910

Copyright@ Caledonian Câbles Offshore & Marine

Page 51: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

49ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

32×2×0.75 0.6 1.2 2.0 36.1 206033×2×0.75 0.6 1.2 2.0 36.9 216037×2×0.75 0.6 1.2 2.0 38.0 23301×3×0.75 0.6 1.1 1.2 11.3 2252×3×0.75 0.6 1.1 1.3 16.4 4903×3×0.75 0.6 1.1 1.4 17.2 5204×3×0.75 0.6 1.1 1.4 18.5 6105×3×0.75 0.6 1.1 1.5 19.8 7206×3×0.75 0.6 1.1 1.5 21.7 8357×3×0.75 0.6 1.1 1.5 21.7 8708×3×0.75 0.6 1.1 1.6 23.5 9509×3×0.75 0.6 1.1 1.6 24.6 106510×3×0.75 0.6 1.1 1.7 26.4 109512×3×0.75 0.6 1.1 1.7 27.3 127514×3×0.75 0.6 1.1 1.8 28.5 132015×3×0.75 0.6 1.1 1.8 29.3 139516×3×0.75 0.6 1.1 1.8 30.1 146518×3×0.75 0.6 1.1 1.9 31.6 160019×3×0.75 0.6 1.1 1.9 31.9 165520×3×0.75 0.6 1.2 2.0 33.2 182021×3×0.75 0.6 1.2 2.0 33.8 189023×3×0.75 0.6 1.2 2.0 35.1 205024×3×0.75 0.6 1.2 2.0 36.0 222027×3×0.75 0.6 1.2 2.1 37.9 233530×3×0.75 0.6 1.2 2.2 39.7 255532×3×0.75 0.6 1.2 2.2 40.7 2690

1×2×1.0 0.6 1.1 1.2 11.4 2302×2×1.0 0.6 1.1 1.3 14.5 3703×2×1.0 0.6 1.1 1.3 16.6 5154×2×1.0 0.6 1.1 1.4 17.4 5955×2×1.0 0.6 1.1 1.4 19.1 6856×2×1.0 0.6 1.1 1.5 20.7 7907×2×1.0 0.6 1.1 1.5 20.7 8208×2×1.0 0.6 1.1 1.6 21.6 8759×2×1.0 0.6 1.1 1.6 23.8 99510×2×1.0 0.6 1.1 1.6 24.8 101012×2×1.0 0.6 1.1 1.7 25.6 119514×2×1.0 0.6 1.1 1.7 26.7 121015×2×1.0 0.6 1.1 1.8 28.5 132016×2×1.0 0.6 1.1 1.8 29.0 137518×2×1.0 0.6 1.1 1.9 30.5 150019×2×1.0 0.6 1.1 1.9 30.8 1555

Copyright@ Caledonian Câbles Offshore & Marine

Page 52: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

50 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

20×2×1.0 0.6 1.1 1.9 31.9 168021×2×1.0 0.6 1.2 2.0 33.3 179023×2×1.0 0.6 1.2 2.0 33.7 192024×2×1.0 0.6 1.2 2.0 35.2 201527×2×1.0 0.6 1.2 2.1 36.5 218530×2×1.0 0.6 1.2 2.1 37.7 236533×2×1.0 0.6 1.2 2.2 39.2 257037×2×1.0 0.6 1.2 2.2 40.4 27751×3×1.0 0.6 1.1 1.2 11.8 2502×3×1.0 0.6 1.1 1.4 17.3 5553×3×1.0 0.6 1.1 1.4 17.9 5904×3×1.0 0.6 1.1 1.4 19.4 7005×3×1.0 0.6 1.1 1.5 20.7 8256×3×1.0 0.6 1.1 1.6 23.0 9757×3×1.0 0.6 1.1 1.6 23.0 9908×3×1.0 0.6 1.1 1.6 24.4 10959×3×1.0 0.6 1.1 1.7 26.4 124510×3×1.0 0.6 1.1 1.8 28.0 126512×3×1.0 0.6 1.1 1.8 28.9 150014×3×1.0 0.6 1.1 1.8 30.0 154515×3×1.0 0.6 1.1 1.9 31.1 165516×3×1.0 0.6 1.1 1.9 31.8 187018×3×1.0 0.6 1.2 2.0 33.9 193519×3×1.0 0.6 1.2 2.0 34.2 204020×3×1.0 0.6 1.2 2.0 35.1 215021×3×1.0 0.6 1.2 2.1 35.9 224523×3×1.0 0.6 1.2 2.1 37.6 252524×3×1.0 0.6 1.2 2.1 38.7 268527×3×1.0 0.6 1.2 2.2 40.3 278530×3×1.0 0.6 1.2 2.3 42.1 305032×3×1.0 0.6 1.2 2.3 43.2 32151×2×1.5 0.7 1.1 1.2 12.4 2702×2×1.5 0.7 1.1 1.4 15.8 4953×2×1.5 0.7 1.1 1.4 17.9 6404×2×1.5 0.7 1.1 1.5 19.5 7155×2×1.5 0.7 1.1 1.5 21.5 8506×2×1.5 0.7 1.1 1.6 23.3 9907×2×1.5 0.7 1.1 1.6 23.3 10308×2×1.5 0.7 1.1 1.7 24.8 11309×2×1.5 0.7 1.1 1.7 26.9 123010×2×1.5 0.7 1.1 1.8 28.2 127012×2×1.5 0.7 1.1 1.8 29.3 1375

Copyright@ Caledonian Câbles Offshore & Marine

Page 53: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

51ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

14×2×1.5 0.7 1.1 1.8 30.2 152015×2×1.5 0.7 1.2 1.9 32.7 168516×2×1.5 0.7 1.2 2.0 33.4 177518×2×1.5 0.7 1.2 2.0 35.0 192019×2×1.5 0.7 1.2 2.0 35.3 199020×2×1.5 0.7 1.2 2.1 37.2 225521×2×1.5 0.7 1.2 2.1 38.2 234523×2×1.5 0.7 1.2 2.2 39.0 254024×2×1.5 0.7 1.2 2.2 40.7 261027×2×1.5 0.7 1.2 2.3 41.7 277530×2×1.5 0.7 1.2 2.3 43.1 300533×2×1.5 0.7 1.4 2.4 45.1 348037×2×1.5 0.7 1.4 2.5 46.7 36001×3×1.5 0.7 1.1 1.2 13.0 3002×3×1.5 0.7 1.1 1.4 17.5 5103×3×1.5 0.7 1.1 1.5 20.1 7404×3×1.5 0.7 1.1 1.5 21.8 8705×3×1.5 0.7 1.1 1.6 23.3 10456×3×1.5 0.7 1.1 1.7 25.9 12307×3×1.5 0.7 1.1 1.7 26.0 12658×3×1.5 0.7 1.1 1.8 27.8 14059×3×1.5 0.7 1.1 1.8 29.5 158510×3×1.5 0.7 1.1 1.9 31.8 168012×3×1.5 0.7 1.2 2.0 33.1 195014×3×1.5 0.7 1.2 2.0 34.6 202015×3×1.5 0.7 1.2 2.0 35.6 214516×3×1.5 0.7 1.2 2.1 36.6 245018×3×1.5 0.7 1.2 2.2 39.2 258019×3×1.5 0.7 1.2 2.2 39.5 267520×3×1.5 0.7 1.2 2.2 40.5 287521×3×1.5 0.7 1.2 2.3 41.5 300023×3×1.5 0.7 1.2 2.3 43.0 326024×3×1.5 0.7 1.4 2.4 44.9 331027×3×1.5 0.7 1.4 2.4 46.4 363530×3×1.5 0.7 1.4 2.5 48.5 398032×3×1.5 0.7 1.4 2.6 50.0 42251×2×2.5 0.7 1.1 1.2 13.3 3202×2×2.5 0.7 1.1 1.4 17.5 5303×2×2.5 0.7 1.1 1.5 20.2 7804×2×2.5 0.7 1.1 1.5 21.5 9005×2×2.5 0.7 1.1 1.6 23.4 10606×2×2.5 0.7 1.1 1.7 25.4 1235

Copyright@ Caledonian Câbles Offshore & Marine

Page 54: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

52 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

7×2×2.5 0.7 1.1 1.7 25.4 12908×2×2.5 0.7 1.1 1.7 27.5 14009×2×2.5 0.7 1.1 1.8 29.4 149510×2×2.5 0.7 1.1 1.9 30.9 159512×2×2.5 0.7 1.1 1.9 31.6 175514×2×2.5 0.7 1.2 2.0 33.6 199015×2×2.5 0.7 1.2 2.1 36.0 216516×2×2.5 0.7 1.2 2.1 36.9 235018×2×2.5 0.7 1.2 2.2 38.9 256519×2×2.5 0.7 1.2 2.2 39.3 266520×2×2.5 0.7 1.2 2.2 40.8 288021×2×2.5 0.7 1.2 2.3 42.1 302023×2×2.5 0.7 1.2 2.3 42.7 325524×2×2.5 0.7 1.4 2.4 45.2 333027×2×2.5 0.7 1.4 2.4 46.1 361530×2×2.5 0.7 1.4 2.5 47.8 395033×2×2.5 0.7 1.4 2.6 49.7 430037×2×2.5 0.7 1.4 2.6 51.2 46701×3×2.5 0.7 1.1 1.3 13.9 3552×3×2.5 0.7 1.1 1.5 20.9 8403×3×2.5 0.7 1.1 1.5 21.6 9454×3×2.5 0.7 1.1 1.6 23.3 11155×3×2.5 0.7 1.1 1.7 25.4 13156×3×2.5 0.7 1.1 1.8 28.3 15557×3×2.5 0.7 1.1 1.8 28.3 16408×3×2.5 0.7 1.1 1.8 30.2 17809×3×2.5 0.7 1.2 1.9 32.6 205510×3×2.5 0.7 1.2 2.0 35.1 208012×3×2.5 0.7 1.2 2.1 36.8 243514×3×2.5 0.7 1.2 2.1 38.3 270015×3×2.5 0.7 1.2 2.2 39.7 289516×3×2.5 0.7 1.2 2.2 40.8 305018×3×2.5 0.7 1.2 2.3 42.9 333519×3×2.5 0.7 1.2 2.3 43.3 347020×3×2.5 0.7 1.4 2.4 44.9 378521×3×2.5 0.7 1.4 2.4 45.8 393523×3×2.5 0.7 1.4 2.5 47.7 415024×3×2.5 0.7 1.4 2.5 48.6 430027×3×2.5 0.7 1.4 2.6 51.1 476530×3×2.5 0.7 1.4 2.7 53.5 523532×3×2.5 0.7 1.6 2.8 55.5 5620

Copyright@ Caledonian Câbles Offshore & Marine

Page 55: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

53ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S2 ou S2/S6 RFOU(c) 250V

Applications

Ces câbles sont ignifuge, sans fumée, halogènes libres et résistant à la boue, util isé pour l ' instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Collectives Blindage: Paires / triples sont layed et collectivement projetés par le

cuivre soutenu polyester bande en contact avec un fil de continuité étamé en cuivre brin. Paires / triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Sans halogène composés thermodurcissables, SHF2 (de TYPE

S2). Gratuit composé thermodurcissable résistant à la boue halogène, boue de la SHF (de TYPE S2/S6), de couleur gris (bleu pour sécurité intrinsèque).

Fil De Cuivre Ètamé

HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUE

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 56: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

54 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 80 90 100 110Nominal Inductance@1KHz MH/km 0.682 0.645 0.632 0.593Maximum L/R@1KHz μH/Ω 20 25 35 50Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

1×2×0.75 0.6 1.1 1.1 11.1 2002×2×0.75 0.6 1.1 1.3 15.0 2953×2×0.75 0.6 1.1 1.3 15.6 3554×2×0.75 0.6 1.1 1.3 16.4 3905×2×0.75 0.6 1.1 1.4 17.8 5406×2×0.75 0.6 1.1 1.4 19.1 6107×2×0.75 0.6 1.1 1.4 19.1 6258×2×0.75 0.6 1.1 1.5 20.7 6809×2×0.75 0.6 1.1 1.5 21.8 74510×2×0.75 0.6 1.1 1.6 22.9 76012×2×0.75 0.6 1.1 1.6 23.4 81014×2×0.75 0.6 1.1 1.6 24.5 87515×2×0.75 0.6 1.1 1.7 26.1 96016×2×0.75 0.6 1.1 1.7 26.5 101018×2×0.75 0.6 1.1 1.8 27.9 108019×2×0.75 0.6 1.1 1.8 28.2 111520×2×0.75 0.6 1.1 1.8 29.2 121021×2×0.75 0.6 1.1 1.8 30.0 125523×2×0.75 0.6 1.1 1.9 30.6 135524×2×0.75 0.6 1.1 1.9 31.9 1370

Copyright@ Caledonian Câbles Offshore & Marine

Page 57: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

55ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

27×2×0.75 0.6 1.2 1.9 32.9 148030×2×0.75 0.6 1.2 2.0 34.1 160533×2×0.75 0.6 1.2 2.0 35.3 172537×2×0.75 0.6 1.2 2.1 36.9 19501×3×0.75 0.6 1.1 1.2 11.7 2302×3×0.75 0.6 1.1 1.3 14.5 3603×3×0.75 0.6 1.1 1.3 16.2 4154×3×0.75 0.6 1.1 1.4 17.6 5405×3×0.75 0.6 1.1 1.4 19.1 6456×3×0.75 0.6 1.1 1.5 21.1 7557×3×0.75 0.6 1.1 1.5 21.1 7808×3×0.75 0.6 1.1 1.6 22.6 8459×3×0.75 0.6 1.1 1.6 23.9 94510×3×0.75 0.6 1.1 1.7 25.7 96012×3×0.75 0.6 1.1 1.7 26.4 108014×3×0.75 0.6 1.1 1.7 27.5 115015×3×0.75 0.6 1.1 1.8 28.5 123016×3×0.75 0.6 1.1 1.8 29.2 131018×3×0.75 0.6 1.1 1.9 30.7 140519×3×0.75 0.6 1.1 1.9 31.0 147520×3×0.75 0.6 1.1 1.9 31.8 156021×3×0.75 0.6 1.2 1.9 32.7 164023×3×0.75 0.6 1.2 2.0 34.1 179524×3×0.75 0.6 1.2 2.0 34.6 183027×3×0.75 0.6 1.2 2.1 36.8 204030×3×0.75 0.6 1.2 2.1 38.3. 221032×3×0.75 0.6 1.2 2.2 39.5 2345

1×2×1.0 0.6 1.1 1.2 11.7 2252×2×1.0 0.6 1.1 1.3 13.4 3353×2×1.0 0.6 1.1 1.3 16.3 4704×2×1.0 0.6 1.1 1.4 17.4 5355×2×1.0 0.6 1.1 1.4 18.7 6106×2×1.0 0.6 1.1 1.5 20.2 7007×2×1.0 0.6 1.1 1.5 20.2 7208×2×1.0 0.6 1.1 1.5 21.8 7759×2×1.0 0.6 1.1 1.6 23.2 85010×2×1.0 0.6 1.1 1.6 24.1 88012×2×1.0 0.6 1.1 1.6 24.7 98014×2×1.0 0.6 1.1 1.7 26.0 103015×2×1.0 0.6 1.1 1.8 27.8 112516×2×1.0 0.6 1.1 1.8 28.2 117518×2×1.0 0.6 1.1 1.8 29.5 125519×2×1.0 0.6 1.1 1.8 29.8 1295

Copyright@ Caledonian Câbles Offshore & Marine

Page 58: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

56 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

20×2×1.0 0.6 1.1 1.9 31.1 142021×2×1.0 0.6 1.1 1.9 31.9 147523×2×1.0 0.6 1.2 1.9 32.7 161024×2×1.0 0.6 1.2 2.0 34.3 162027×2×1.0 0.6 1.2 2.0 35.0 174530×2×1.0 0.6 1.2 2.1 36.7 198033×2×1.0 0.6 1.2 2.1 38.0 213037×2×1.0 0.6 1.2 2.2 39.3 23051×3×1.0 0.6 1.1 1.2 12.0 2502×3×1.0 0.6 1.1 1.4 17.0 5203×3×1.0 0.6 1.1 1.4 17.4 5404×3×1.0 0.6 1.1 1.4 18.7 6255×3×1.0 0.6 1.1 1.5 20.2 7456×3×1.0 0.6 1.1 1.6 22.4 8757×3×1.0 0.6 1.1 1.6 22.4 9058×3×1.0 0.6 1.1 1.6 23.8 9809×3×1.0 0.6 1.1 1.7 25.4 108010×3×1.0 0.6 1.1 1.7 27.1 115012×3×1.0 0.6 1.1 1.8 28.1 126514×3×1.0 0.6 1.1 1.8 29.2 135515×3×1.0 0.6 1.1 1.8 30.1 144016×3×1.0 0.6 1.1 1.9 31.1 157018×3×1.0 0.6 1.2 1.9 32.8 167519×3×1.0 0.6 1.2 2.0 33.3 175020×3×1.0 0.6 1.2 2.0 34.1 188021×3×1.0 0.6 1.2 2.0 34.8 195023×3×1.0 0.6 1.2 2.1 36.6 221524×3×1.0 0.6 1.2 2.1 37.3 220027×3×1.0 0.6 1.2 2.2 39.2 242530×3×1.0 0.6 1.2 2.2 40.8 263032×3×1.0 0.6 1.2 2.3 42.1 27901×2×1.5 0.7 1.1 1.2 12.7 2602×2×1.5 0.7 1.1 1.4 15.4 4203×2×1.5 0.7 1.1 1.4 17.6 5854×2×1.5 0.7 1.1 1.4 18.8 6355×2×1.5 0.7 1.1 1.5 21.1 7706×2×1.5 0.7 1.1 1.6 22.8 8907×2×1.5 0.7 1.1 1.6 22.8 9258×2×1.5 0.7 1.1 1.6 23.7 9759×2×1.5 0.7 1.1 1.7 26.3 106010×2×1.5 0.7 1.1 1.7 27.4 113012×2×1.5 0.7 1.1 1.8 28.3 127014×2×1.5 0.7 1.1 1.8 29.5 1325

Copyright@ Caledonian Câbles Offshore & Marine

Page 59: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

57ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

15×2×1.5 0.7 1.1 1.9 31.6 144516×2×1.5 0.7 1.1 1.9 32.1 157518×2×1.5 0.7 1.2 2.0 34.2 167019×2×1.5 0.7 1.2 2.0 34.5 176520×2×1.5 0.7 1.2 2.1 36.0 189521×2×1.5 0.7 1.2 2.1 37.3 205023×2×1.5 0.7 1.2 2.1 37.9 218524×2×1.5 0.7 1.2 2.2 39.8 220027×2×1.5 0.7 1.2 2.2 40.6 239030×2×1.5 0.7 1.2 2.3 42.1 260033×2×1.5 0.7 1.2 2.3 43.6 280537×2×1.5 0.7 1.4 2.4 45.4 30801×3×1.5 0.7 1.1 1.2 13.2 2952×3×1.5 0.7 1.1 1.4 17.0 4903×3×1.5 0.7 1.1 1.5 19.5 6854×3×1.5 0.7 1.1 1.5 20.9 7855×3×1.5 0.7 1.1 1.6 21.0 8206×3×1.5 0.7 1.1 1.7 22.8 9607×3×1.5 0.7 1.1 1.7 25.1 11358×3×1.5 0.7 1.1 1.7 27.0 12709×3×1.5 0.7 1.1 1.8 28.9 144510×3×1.5 0.7 1.1 1.9 31.1 145012×3×1.5 0.7 1.1 1.9 31.5 171014×3×1.5 0.7 1.2 2.0 33.8 181515×3×1.5 0.7 1.2 2.0 34.8 193016×3×1.5 0.7 1.2 2.1 36.0 211018×3×1.5 0.7 1.2 2.1 38.1 230519×3×1.5 0.7 1.2 2.2 38.6 237520×3×1.5 0.7 1.2 2.2 39.6 258021×3×1.5 0.7 1.2 2.2 40.4 268023×3×1.5 0.7 1.2 2.3 42.0 292524×3×1.5 0.7 1.2 2.3 42.7 314027×3×1.5 0.7 1.4 2.4 45.3 325030×3×1.5 0.7 1.4 2.5 47.4 355532×3×1.5 0.7 1.4 2.5 48.6 37451×2×2.5 0.7 1.1 1.2 13.5 3002×2×2.5 0.7 1.1 1.4 18.9 6503×2×2.5 0.7 1.1 1.5 19.9 7204×2×2.5 0.7 1.1 1.5 21.1 8205×2×2.5 0.7 1.1 1.6 23.0 9656×2×2.5 0.7 1.1 1.6 24.8 11057×2×2.5 0.7 1.1 1.6 24.8 11508×2×2.5 0.7 1.1 1.7 27.0 1255

Copyright@ Caledonian Câbles Offshore & Marine

Page 60: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

58 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

9×2×2.5 0.7 1.1 1.8 28.8 138510×2×2.5 0.7 1.1 1.8 30.0 143012×2×2.5 0.7 1.3 1.9 31.0 154514×2×2.5 0.7 1.2 1.9 32.7 173015×2×2.5 0.7 1.2 2.0 35.0 188516×2×2.5 0.7 1.2 2.0 35.6 197018×2×2.5 0.7 1.2 2.1 37.9 223519×2×2.5 0.7 1.2 2.1 38.3 231520×2×2.5 0.7 1.2 2.2 39.9 253021×2×2.5 0.7 1.2 2.2 41.0 263023×2×2.5 0.7 1.2 2.3 41.8 275024×2×2.5 0.7 1.2 2.3 43.7 285027×2×2.5 0.7 1.4 2.4 45.1 315030×2×2.5 0.7 1.4 2.5 46.8 343533×2×2.5 0.7 1.4 2.5 48.5 371537×2×2.5 0.7 1.4 2.6 50.2 40401×3×2.5 0.7 1.1 1.3 14.3 3602×3×2.5 0.7 1.1 1.5 20.5 7853×3×2.5 0.7 1.1 1.5 21.2 8754×3×2.5 0.7 1.1 1.6 22.9 10355×3×2.5 0.7 1.1 1.6 24.8 12056×3×2.5 0.7 1.1 1.8 27.8 14307×3×2.5 0.7 1.1 1.8 27.8 15058×3×2.5 0.7 1.1 1.8 29.6 16259×3×2.5 0.7 1.1 1.9 31.7 185510×3×2.5 0.7 1.2 2.0 34.4 189012×3×2.5 0.7 1.2 2.0 35.5 211014×3×2.5 0.7 1.2 2.1 37.6 244515×3×2.5 0.7 1.2 2.2 38.9 262016×3×2.5 0.7 1.2 2.2 40.0 275518×3×2.5 0.7 1.2 2.3 42.0 301019×3×2.5 0.7 1.2 2.3 42.4 312520×3×2.5 0.7 1.2 2.3 43.5 336021×3×2.5 0.7 1.4 2.4 44.9 355523×3×2.5 0.7 1.4 2.5 46.7 388524×3×2.5 0.7 1.4 2.5 47.5 387027×3×2.5 0.7 1.4 2.6 50.0 428030×3×2.5 0.7 1.4 2.7 52.3 469532×3×2.5 0.7 1.4 2.7 53.8 4960

Copyright@ Caledonian Câbles Offshore & Marine

Page 61: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

59ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

P16 IFLI 250 V

Applications

Ces câbles sont retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les zones de vie, trimestre et de bureau.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil de cuivre brin circulaire CEI 60228 classe 2. Isolation: XLPE. Literie: Composé thermoplastique sans halogène. Écran métallique: Ruban aluminium longitudinal, une épaisseur de 0,2 mm en contact

avec un conducteur de terre en cuivre brin. Gaine extérieure: Gratuit composé thermoplastique d’halogène, SHF1, couleur gris.

Caractéristiques électriques

Cross Section Nominale Zone mm² 2.5Maximum résistant@20℃ Ω/km 7.41Courant Nominal Continu@45℃ 2 Core A 261s courant de court circuit A 360Tension de fonctionnement V 250

XLPE Isolation

Conducteur En Cuivre Multibrins

SHF1 Gaine

Halogène Gratuit Literie Thermoplastique

Ruban Aluminium + Conducteur De Terre

Copyright@ Caledonian Câbles Offshore & Marine

Page 62: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

60 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

Intérieure Extérieur

2×1×2.5 0.7 1.1 1.2 10.0 180

Copyright@ Caledonian Câbles Offshore & Marine

Page 63: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

61ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S11 RU(i) 250 V

Applications

Ces câbles non armés sont ignifuge, sans fumée et halogènes, utilisés pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Blindage individuel : Chaque paires/triples sont examinées par ruban de polyester

soutenue en cuivre en contact avec un fil de drain en cuivre étamé toronné et enveloppé avec du ruban adhésif polyester. Couples/triples sont numérotés avec un ruban numéroté ou par numéros imprimés directement sur les conducteurs isolés.

Gaine extérieure: Composés thermodurcissables libre d’halogène, SHF2, couleur gris (bleu pour sécurité intrinsèque).

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0

HFEPR Isolation

Conducteur En Cuivre Multibrins

SHF2 Gaine

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 64: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

62 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×2×0.75 0.6 1.0 7.6 952×2×0.75 0.6 1.1 9.7 1804×2×0.75 0.6 1.2 12.1 2557×2×0.75 0.6 1.3 14.4 3808×2×0.75 0.6 1.3 15.6 425

12×2×0.75 0.6 1.5 19.0 61016×2×0.75 0.6 1.5 21.0 78519×2×0.75 0.6 1.6 22.4 89524×2×0.75 0.6 1.7 25.6 113532×2×0.75 0.6 1.8 28.4 14401×3×0.75 0.6 1.0 8.0 1102×3×0.75 0.6 1.2 11.0 1803×3×0.75 0.6 1.2 12.7 2654×3×0.75 0.6 1.2 13.8 3257×3×0.75 0.6 1.4 16.7 5008×3×0.75 0.6 1.4 18.0 540

12×3×0.75 0.6 1.6 22.2 81516×3×0.75 0.6 1.6 24.7 104519×3×0.75 0.6 1.7 26.2 120524×3×0.75 0.6 1.9 30.5 1545

1×2×1.0 0.6 1.0 8.1 1102×2×1.0 0.6 1.1 10.4 2154×2×1.0 0.6 1.2 12.9 3107×2×1.0 0.6 1.4 15.5 4758×2×1.0 0.6 1.4 17.0 540

Copyright@ Caledonian Câbles Offshore & Marine

Page 65: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

63ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

12×2×1.0 0.6 1.5 20.5 76016×2×1.0 0.6 1.5 22.9 99519×2×1.0 0.6 1.7 24.1 113524×2×1.0 0.6 1.8 27.8 145032×2×1.0 0.6 1.9 30.8 18501×3×1.0 0.6 1.0 8.5 1253×3×1.0 0.6 1.3 13.4 3204×3×1.0 0.6 1.3 14.8 3957×3×1.0 0.6 1.5 17.9 61512×3×1.0 0.6 1.6 23.7 99016×3×1.0 0.6 1.7 26.5 129519×3×1.0 0.6 1.8 28.0 147524×3×1.0 0.6 2.0 32.6 19001×2×1.5 0.7 1.0 9.1 1402×2×1.5 0.7 1.2 11.7 2804×2×1.5 0.7 1.3 14.9 4107×2×1.5 0.7 1.5 18.0 6358×2×1.5 0.7 1.5 19.7 72012×2×1.5 0.7 1.6 23.8 101516×2×1.5 0.7 1.6 26.6 133019×2×1.5 0.7 1.9 28.3 152524×2×1.5 0.7 2.0 32.6 194532×2×1.5 0.7 2.2 36.1 24751×3×1.5 0.7 1.0 9.5 1602×3×1.5 0.7 1.3 14.0 2853×3×1.5 0.7 1.3 15.5 4254×3×1.5 0.7 1.3 17.0 5257×3×1.5 0.7 1.6 20.9 8308×3×1.5 0.7 1.6 22.5 90012×3×1.5 0.7 1.8 27.6 134016×3×1.5 0.7 1.9 31.1 177019×3×1.5 0.7 2.0 32.8 202024×3×1.5 0.7 2.2 38.4 26101×2×2.5 0.7 1.0 9.8 1751×3×2.5 0.7 1.2 10.4 205

Copyright@ Caledonian Câbles Offshore & Marine

Page 66: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

64 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S12 RU(c) 250 V

Applications

Ces câbles non armés sont ignifuge, sans fumée et halogènes, utilisés pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Collectives Blindage: Paires / triples sont layed et collectivement projetés par le

cuivre soutenu polyester bande en contact avec un fil de continuité étamé en cuivre brin. Paires / triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés.

Gaine extérieure: Composés thermodurcissables libre d’halogène, SHF2, couleur gris (bleu pour sécurité intrinsèque).

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6

HFEPR Isolation

Conducteur En Cuivre Multibrins

SHF2 Gaine

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 67: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

65ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Maximum résistant@20℃ Ω/km 26.3 19.3 12.9Capacité mutuelle nF/km 80 90 100Nominal Inductance@1KHz MH/km 0.682 0.645 0.632Maximum L/R@1KHz μH/Ω 20 25 35Tension de fonctionnement V 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

2×2×0.75 0.6 1.1 9.4 1604×2×0.75 0.6 1.1 11.5 2157×2×0.75 0.6 1.3 13.6 3008×2×0.75 0.6 1.3 14.7 34012×2×0.75 0.6 1.4 17.6 46516×2×0.75 0.6 1.5 19.7 59519×2×0.75 0.6 1.5 20.7 66524×2×0.75 0.6 1.7 24.1 85032×2×0.75 0.6 2.0 26.7 10652×3×0.75 0.6 1.1 11.0 1703×3×0.75 0.6 1.1 12.1 2354×3×0.75 0.6 1.2 13.1 2807×3×0.75 0.6 1.4 15.7 4108×3×0.75 0.6 1.4 17.5 49012×3×0.75 0.6 1.5 20.6 64516×3×0.75 0.6 1.6 23.1 83519×3×0.75 0.6 1.7 24.3 94024×3×0.75 0.6 1.8 28.2 1210

2×2×1.0 0.6 1.1 9.9 1904×2×1.0 0.6 1.1 12.3 2557×2×1.0 0.6 1.3 14.7 3708×2×1.0 0.6 1.3 15.7 41012×2×1.0 0.6 1.5 18.9 56516×2×1.0 0.6 1.6 21.1 73019×2×1.0 0.6 1.7 22.5 830

Copyright@ Caledonian Câbles Offshore & Marine

Page 68: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Instrumentation

66 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

24×2×1.0 0.6 1.8 25.9 105032×2×1.0 0.6 2.1 28.7 13153×3×1.0 0.6 1.1 12.9 2804×3×1.0 0.6 1.3 14.0 3357×3×1.0 0.6 1.5 16.9 50012×3×1.0 0.6 1.6 22.1 79516×3×1.0 0.6 1.6 24.8 102519×3×1.0 0.6 1.8 26.3 117524×3×1.0 0.6 2.0 30.4 14902×2×1.5 0.7 1.2 11.3 2504×2×1.5 0.7 1.2 14.1 3457×2×1.5 0.7 1.4 17.2 5158×2×1.5 0.7 1.4 18.4 57512×2×1.5 0.7 1.6 22.4 81016×2×1.5 0.7 1.7 25.0 104519×2×1.5 0.7 1.8 26.4 117524×2×1.5 0.7 1.9 30.7 150532×2×1.5 0.7 2.2 33.9 18902×3×1.5 0.7 1.2 13.5 2653×3×1.5 0.7 1.2 14.9 3804×3×1.5 0.7 1.3 16.3 4657×3×1.5 0.7 1.5 19.8 7058×3×1.5 0.7 1.5 21.5 82012×3×1.5 0.7 1.7 26.2 114016×3×1.5 0.7 1.8 29.4 147519×3×1.5 0.7 1.9 30.9 167524×3×1.5 0.7 2.1 36.2 2160

Copyright@ Caledonian Câbles Offshore & Marine

Page 69: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

67ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S3 ou S3/S7 BFOU(i) 250V

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Blindage individuel : Chaque paires/triples sont examinées par ruban de polyester

soutenue en cuivre en contact avec un fil de drain en cuivre étamé toronné et enveloppé avec du ruban adhésif polyester. Couples/triples sont numérotés avec un ruban numéroté ou par numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Halogène composé thermodurcissable libre, SHF2 (pour le TYPE

S3). Halogène MUD gratuitement composé thermodurcissable résistant, SHF MUD (pour le TYPE S3/S7), de couleur grise (de bleu pour sécurité intrinsèque).

Fil De Cuivre Ètamé

Ruban Mica + HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2 Gaine

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 70: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

68 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

1×2×0.75 0.6 1.1 1.2 12.1 2252×2×0.75 0.6 1.1 1.3 16.7 4053×2×0.75 0.6 1.1 1.4 17.5 5404×2×0.75 0.6 1.1 1.4 18.6 6105×2×0.75 0.6 1.1 1.5 20.2 7056×2×0.75 0.6 1.1 1.5 21.7 8057×2×0.75 0.6 1.1 1.5 21.7 8308×2×0.75 0.6 1.1 1.6 23.6 9059×2×0.75 0.6 1.1 1.7 25.1 100010×2×0.75 0.6 1.1 1.7 26.2 103012×2×0.75 0.6 1.1 1.7 26.8 114514×2×0.75 0.6 1.1 1.8 28.2 120515×2×0.75 0.6 1.1 1.8 30.0 130516×2×0.75 0.6 1.1 1.9 30.6 141518×2×0.75 0.6 1.1 1.9 32.1 147519×2×0.75 0.6 1.2 1.9 32.7 157520×2×0.75 0.6 1.2 2.0 34.1 1700

Copyright@ Caledonian Câbles Offshore & Marine

Page 71: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

69ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

21×2×0.75 0.6 1.2 2.0 35.0 176523×2×0.75 0.6 1.2 2.0 35.5 189524×2×0.75 0.6 1.2 2.1 37.7 198027×2×0.75 0.6 1.2 2.2 38.7 216530×2×0.75 0.6 1.2 2.2 39.9 233533×2×0.75 0.6 1.2 2.3 41.5 253537×2×0.75 0.6 1.2 2.3 42.7 27251×3×0.75 0.6 1.1 1.1 11.9 2452×3×0.75 0.6 1.1 1.4 15.5 4203×3×0.75 0.6 1.1 1.4 18.4 5804×3×0.75 0.6 1.1 1.4 19.7 6757×3×0.75 0.6 1.1 1.6 23.6 9608×3×0.75 0.6 1.1 1.7 25.0 980

12×3×0.75 0.6 1.3 1.8 29.6 143516×3×0.75 0.6 1.4 1.9 32.6 177019×3×0.75 0.6 1.4 2.1 34.4 198524×3×0.75 0.6 1.8 2.2 39.6 25801×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.6 4503×2×1.0 0.6 1.1 1.4 18.3 6004×2×1.0 0.6 1.1 1.4 19.3 6255×2×1.0 0.6 1.1 1.5 21.1 9206×2×1.0 0.6 1.1 1.6 22.8 9507×2×1.0 0.6 1.1 1.6 22.8 8608×2×1.0 0.6 1.1 1.6 24.7 9859×2×1.0 0.6 1.1 1.7 26.3 113510×2×1.0 0.6 1.1 1.7 27.4 117012×2×1.0 0.6 1.1 1.8 28.3 130014×2×1.0 0.6 1.1 1.8 29.5 138015×2×1.0 0.6 1.1 1.9 31.6 151016×2×1.0 0.6 1.1 1.9 32.1 162018×2×1.0 0.6 1.2 2.0 34.2 174519×2×1.0 0.6 1.2 2.0 34.5 183020×2×1.0 0.6 1.2 2.1 36.0 197521×2×1.0 0.6 1.2 2.1 37.3 213523×2×1.0 0.6 1.2 2.1 37.9 229524×2×1.0 0.6 1.2 2.2 39.8 233527×2×1.0 0.6 1.2 2.2 40.6 250030×2×1.0 0.6 1.2 2.3 42.1 272033×2×1.0 0.6 1.2 2.3 43.6 2940

Copyright@ Caledonian Câbles Offshore & Marine

Page 72: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

70 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

37×2×1.0 0.6 1.4 2.4 45.4 32301×3×1.0 0.6 1.1 1.2 12.6 2752×3×1.0 0.6 1.1 1.4 18.8 6403×3×1.0 0.6 1.1 1.5 19.3 6654×3×1.0 0.6 1.1 1.5 20.9 7755×3×1.0 0.6 1.1 1.6 22.8 9656×3×1.0 0.6 1.1 1.7 25.4 11357×3×1.0 0.6 1.1 1.7 25.4 11808×3×1.0 0.6 1.1 1.7 27.0 12709×3×1.0 0.6 1.1 1.8 28.9 1450

10×3×1.0 0.6 1.1 1.9 31.1 145512×3×1.0 0.6 1.1 1.9 32.0 168514×3×1.0 0.6 1.2 2.0 33.8 182015×3×1.0 0.6 1.2 2.0 34.8 193516×3×1.0 0.6 1.2 2.1 36.0 210518×3×1.0 0.6 1.2 2.1 38.1 231019×3×1.0 0.6 1.2 2.2 38.6 235520×3×1.0 0.6 1.2 2.2 39.6 259021×3×1.0 0.6 1.2 2.2 40.4 268523×3×1.0 0.6 1.2 2.3 42.0 293524×3×1.0 0.6 1.2 2.3 42.8 314527×3×1.0 0.6 1.4 2.4 45.3 325530×3×1.0 0.6 1.4 2.5 47.4 356532×3×1.0 0.6 1.4 2.5 48.6 37551×2×1.5 0.7 1.1 1.2 13.5 2952×2×1.5 0.7 1.1 1.4 19.2 5453×2×1.5 0.7 1.1 1.5 20.2 7254×2×1.5 0.7 1.1 1.5 21.5 7705×2×1.5 0.7 1.1 1.6 23.4 9756×2×1.5 0.7 1.1 1.7 25.4 11307×2×1.5 0.7 1.1 1.7 25.4 11708×2×1.5 0.7 1.1 1.7 27.5 12259×2×1.5 0.7 1.1 1.8 29.4 1405

10×2×1.5 0.7 1.1 1.9 30.9 144012×2×1.5 0.7 1.1 1.9 31.6 168014×2×1.5 0.7 1.2 2.0 33.6 175015×2×1.5 0.7 1.2 2.1 36.0 191016×2×1.5 0.7 1.2 2.1 36.9 205518×2×1.5 0.7 1.2 2.2 38.9 226019×2×1.5 0.7 1.2 2.2 39.3 2395

Copyright@ Caledonian Câbles Offshore & Marine

Page 73: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

71ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

20×2×1.5 0.7 1.2 2.2 40.8 254021×2×1.5 0.7 1.2 2.3 42.1 266023×2×1.5 0.7 1.2 2.3 42.7 286524×2×1.5 0.7 1.4 2.4 45.2 308027×2×1.5 0.7 1.4 2.4 46.1 315530×2×1.5 0.7 1.4 2.5 47.8 344032×2×1.5 0.7 1.4 2.6 49.0 368533×2×1.5 0.7 1.4 2.6 49.7 374037×2×1.5 0.7 1.4 2.6 51.2 40401×3×1.5 0.7 1.1 1.3 13.6 3252×3×1.5 0.7 1.1 1.5 18.5 5603×3×1.5 0.7 1.1 1.5 21.4 8004×3×1.5 0.7 1.1 1.6 23.7 9755×3×1.5 0.7 1.1 1.7 25.4 11956×3×1.5 0.7 1.1 1.8 28.3 14057×3×1.5 0.7 1.1 1.8 28.3 14708×3×1.5 0.7 1.1 1.8 30.2 15859×3×1.5 0.7 1.2 1.9 32.6 1835

10×3×1.5 0.7 1.2 2.0 35.1 193512×3×1.5 0.7 1.2 2.1 36.8 211514×3×1.5 0.7 1.2 2.1 38.3 236015×3×1.5 0.7 1.2 2.2 39.7 253016×3×1.5 0.7 1.2 2.2 40.8 277518×3×1.5 0.7 1.2 2.3 42.9 290519×3×1.5 0.7 1.2 2.3 43.3 320020×3×1.5 0.7 1.4 2.4 44.9 330521×3×1.5 0.7 1.4 2.4 45.8 343023×3×1.5 0.7 1.4 2.5 47.7 375524×3×1.5 0.7 1.4 2.5 48.6 392527×3×1.5 0.7 1.4 2.6 51.1 411530×3×1.5 0.7 1.4 2.7 53.5 451032×3×1.5 0.7 1.6 2.8 55.5 48501×2×2.5 0.7 1.1 1.3 14.0 3402×2×2.5 0.7 1.1 1.5 18.5 5603×2×2.5 0.7 1.1 1.5 21.6 8654×2×2.5 0.7 1.1 1.6 23.2 10105×2×2.5 0.7 1.1 1.7 25.3 11856×2×2.5 0.7 1.1 1.7 27.4 13707×2×2.5 0.7 1.1 1.7 27.4 14308×2×2.5 0.7 1.1 1.8 29.9 1560

Copyright@ Caledonian Câbles Offshore & Marine

Page 74: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

72 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

9×2×2.5 0.7 1.1 1.9 31.9 178010×2×2.5 0.7 1.2 2.0 33.8 177512×2×2.5 0.7 1.2 2.0 34.6 196514×2×2.5 0.7 1.2 2.1 36.9 227515×2×2.5 0.7 1.2 2.2 39.5 248016×2×2.5 0.7 1.2 2.2 40.1 259018×2×2.5 0.7 1.2 2.3 42.3 282519×2×2.5 0.7 1.2 2.3 42.7 293020×2×2.5 0.7 1.4 2.4 44.8 324021×2×2.5 0.7 1.4 2.4 46.1 337523×2×2.5 0.7 1.4 2.5 46.9 356024×2×2.5 0.7 1.4 2.5 49.1 366027×2×2.5 0.7 1.4 2.6 50.3 400030×2×2.5 0.7 1.4 2.7 52.2 437033×2×2.5 0.7 1.4 2.7 54.1 473537×2×2.5 0.7 1.6 2.8 56.4 52251×3×2.5 0.7 1.1 1.2 14.5 3802×3×2.5 0.7 1.1 1.6 22.5 9503×3×2.5 0.7 1.1 1.6 23.4 10554×3×2.5 0.7 1.1 1.7 25.3 12505×3×2.5 0.7 1.1 1.7 27.4 14606×3×2.5 0.7 1.1 1.9 30.7 17357×3×2.5 0.7 1.1 1.9 30.7 18308×3×2.5 0.7 1.2 2.0 33.3 20259×3×2.5 0.7 1.2 2.0 35.4 2290

10×3×2.5 0.7 1.2 2.2 38.8 240512×3×2.5 0.7 1.2 2.2 40.0 268514×3×2.5 0.7 1.2 2.3 41.9 300015×3×2.5 0.7 1.2 2.3 43.1 319016×3×2.5 0.7 1.4 2.4 44.9 342018×3×2.5 0.7 1.4 2.5 47.2 374019×3×2.5 0.7 1.4 2.5 47.6 388520×3×2.5 0.7 1.4 2.5 48.9 418521×3×2.5 0.7 1.4 2.6 50.0 437023×3×2.5 0.7 1.4 2.7 52.1 476024×3×2.5 0.7 1.4 2.7 53.0 478527×3×2.5 0.7 1.6 2.8 56.2 533530×3×2.5 0.7 1.6 2.9 58.8 585532×3×2.5 0.7 1.6 3.0 60.6 6215

Copyright@ Caledonian Câbles Offshore & Marine

Page 75: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

73ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S4 ou S4/S8 BFOU(c) 250V

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée, sans halogène et résistants boue, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Collectives Blindage: Paires / triples sont layed et collectivement projetés par le

cuivre soutenu polyester bande en contact avec un fil de continuité étamé en cuivre brin. Paires / triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Sans halogène composés thermodurcissables, SHF2 (pour TYPE

S4). Gratuit composé thermodurcissable résistant à la boue halogène, boue de la SHF (pour TYPE S4/S8), de couleur gris (bleu pour sécurité intrinsèque).

Fil De Cuivre Ètamé

Ruban Mica + HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF2/SHF Gaine De BOUE

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 76: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

74 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 75 80 85 95Nominal Inductance@1KHz MH/km 0.727 0.686 0.667 0.623Maximum L/R@1KHz μH/Ω 20 25 35 55Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément

× coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

1×2×0.75 0.6 1.1 1.2 12.1 2302×2×0.75 0.6 1.1 1.3 16.4 3403×2×0.75 0.6 1.1 1.4 17.2 4954×2×0.75 0.6 1.1 1.4 18.2 5555×2×0.75 0.6 1.1 1.5 19.8 6406×2×0.75 0.6 1.1 1.5 21.2 7257×2×0.75 0.6 1.1 1.5 21.2 7408×2×0.75 0.6 1.1 1.6 23.1 8059×2×0.75 0.6 1.1 1.6 24.3 880

10×2×0.75 0.6 1.1 1.7 25.6 90012×2×0.75 0.6 1.1 1.7 26.2 95014×2×0.75 0.6 1.1 1.7 27.3 103515×2×0.75 0.6 1.1 1.8 29.2 113016×2×0.75 0.6 1.1 1.8 29.7 117518×2×0.75 0.6 1.1 1.9 31.3 127519×2×0.75 0.6 1.1 1.9 31.6 131520×2×0.75 0.6 1.2 2.0 33.3 147521×2×0.75 0.6 1.2 2.0 34.1 153023×2×0.75 0.6 1.2 2.0 34.6 163524×2×0.75 0.6 1.2 2.1 36.8 173027×2×0.75 0.6 1.2 2.1 37.5 1850

Copyright@ Caledonian Câbles Offshore & Marine

Page 77: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

75ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément

× coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

30×2×0.75 0.6 1.2 2.2 38.9 196533×2×0.75 0.6 1.2 2.2 40.3 215537×2×0.75 0.6 1.2 2.3 41.7 23251×3×0.75 0.6 1.1 1.2 12.6 2552×3×0.75 0.6 1.1 1.4 17.7 5453×3×0.75 0.6 1.1 1.4 18.3 5854×3×0.75 0.6 1.1 1.5 19.7 6705×3×0.75 0.6 1.1 1.5 21.2 7706×3×0.75 0.6 1.1 1.6 23.5 9007×3×0.75 0.6 1.1 1.6 23.5 9358×3×0.75 0.6 1.1 1.7 25.2 10159×3×0.75 0.6 1.1 1.7 26.7 113510×3×0.75 0.6 1.1 1.8 28.7 114012×3×0.75 0.6 1.1 1.8 29.6 123014×3×0.75 0.6 1.1 1.9 31.0 137515×3×0.75 0.6 1.1 1.9 31.9 145516×3×0.75 0.6 1.2 2.0 33.3 154518×3×0.75 0.6 1.2 2.0 34.8 169019×3×0.75 0.6 1.2 2.0 35.1 175020×3×0.75 0.6 1.2 2.1 36.6 198521×3×0.75 0.6 1.2 2.1 37.3 205523×3×0.75 0.6 1.2 2.2 38.8 221524×3×0.75 0.6 1.2 2.2 39.5 224527×3×0.75 0.6 1.2 2.3 41.5 243530×3×0.75 0.6 1.2 2.3 43.3 264532×3×0.75 0.6 1.4 2.4 44.9 28401×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.2 3753×2×1.0 0.6 1.1 1.4 17.9 5504×2×1.0 0.6 1.1 1.4 19.0 6155×2×1.0 0.6 1.1 1.5 20.6 7106×2×1.0 0.6 1.1 1.6 22.4 8207×2×1.0 0.6 1.1 1.6 22.4 8458×2×1.0 0.6 1.1 1.6 24.1 9059×2×1.0 0.6 1.1 1.7 25.7 99510×2×1.0 0.6 1.1 1.7 26.8 103512×2×1.0 0.6 1.1 1.7 27.4 109514×2×1.0 0.6 1.1 1.8 28.9 119515×2×1.0 0.6 1.1 1.9 30.9 130516×2×1.0 0.6 1.1 1.9 31.4 135518×2×1.0 0.6 1.2 2.0 33.4 150019×2×1.0 0.6 1.2 2.0 33.7 1550

Copyright@ Caledonian Câbles Offshore & Marine

Page 78: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

76 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément

× coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

20×2×1.0 0.6 1.2 2.0 35.0 168521×2×1.0 0.6 1.2 2.1 36.5 185023×2×1.0 0.6 1.2 2.1 37.0 197524×2×1.0 0.6 1.2 2.2 38.9 199027×2×1.0 0.6 1.2 2.2 39.6 213530×2×1.0 0.6 1.2 2.2 40.9 230033×2×1.0 0.6 1.2 2.3 42.5 249537×2×1.0 0.6 1.4 2.4 44.3 27351×3×1.0 0.6 1.1 1.2 13.0 2802×3×1.0 0.6 1.1 1.4 18.0 5503×3×1.0 0.6 1.1 1.4 18.7 6004×3×1.0 0.6 1.1 1.5 20.0 6905×3×1.0 0.6 1.1 1.6 22.4 8806×3×1.0 0.6 1.1 1.6 24.6 10207×3×1.0 0.6 1.1 1.6 24.6 10608×3×1.0 0.6 1.1 1.7 26.4 11509×3×1.0 0.6 1.1 1.8 28.2 1305

10×3×1.0 0.6 1.1 1.8 30.2 129012×3×1.0 0.6 1.1 1.9 31.3 143514×3×1.0 0.6 1.2 1.9 32.9 160515×3×1.0 0.6 1.2 2.0 34.0 172016×3×1.0 0.6 1.2 2.0 35.0 176518×3×1.0 0.6 1.2 2.1 37.2 205019×3×1.0 0.6 1.2 2.1 37.5 212020×3×1.0 0.6 1.2 2.2 38.7 230021×3×1.0 0.6 1.2 2.2 39.4 238023×3×1.0 0.6 1.2 2.2 40.8 251524×3×1.0 0.6 1.2 2.3 41.7 257527×3×1.0 0.6 1.2 2.3 43.7 281530×3×1.0 0.6 1.4 2.4 46.1 312532×3×1.0 0.6 1.4 2.5 47.5 33101×2×1.5 0.7 1.1 1.3 14.3 3352×2×1.5 0.7 1.1 1.5 20.5 7403×2×1.5 0.7 1.1 1.5 21.2 8054×2×1.5 0.7 1.1 1.6 22.9 9455×2×1.5 0.7 1.1 1.6 24.8 10956×2×1.5 0.7 1.1 1.8 27.8 13007×2×1.5 0.7 1.1 1.8 27.8 13558×2×1.5 0.7 1.1 1.8 29.6 14559×2×1.5 0.7 1.1 1.9 31.7 1660

10×2×1.5 0.7 1.1 2.0 34.4 168012×2×1.5 0.7 1.1 2.0 35.5 1855

Copyright@ Caledonian Câbles Offshore & Marine

Page 79: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

77ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément

× coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

14×2×1.5 0.7 1.2 2.1 37.6 215015×2×1.5 0.7 1.2 2.2 38.9 230016×2×1.5 0.7 1.2 2.2 40.0 241518×2×1.5 0.7 1.2 2.3 42.0 263019×2×1.5 0.7 1.2 2.3 42.4 272520×2×1.5 0.7 1.2 2.3 43.5 294021×2×1.5 0.7 1.2 2.4 44.9 311023×2×1.5 0.7 1.2 2.5 46.7 340024×2×1.5 0.7 1.2 2.5 47.5 336027×2×1.5 0.7 1.4 2.6 50.0 371030×2×1.5 0.7 1.4 2.7 52.3 406032×2×1.5 0.7 1.4 2.7 53.8 428533×2×1.5 0.7 1.4 2.5 48.5 324537×2×1.5 0.7 1.4 2.6 50.2 35151×3×1.5 0.7 1.1 1.3 14.3 3352×3×1.5 0.7 1.1 1.5 20.5 7403×3×1.5 0.7 1.1 1.5 21.2 8054×3×1.5 0.7 1.1 1.6 22.9 9455×3×1.5 0.7 1.1 1.6 24.8 10956×3×1.5 0.7 1.1 1.8 27.8 13007×3×1.5 0.7 1.1 1.8 27.8 13558×3×1.5 0.7 1.1 1.8 29.6 14559×3×1.5 0.7 1.1 1.9 31.7 1660

10×3×1.5 0.7 1.2 2.0 34.4 168012×3×1.5 0.7 1.2 2.0 35.5 185514×3×1.5 0.7 1.2 2.1 37.6 215015×3×1.5 0.7 1.2 2.2 38.9 230016×3×1.5 0.7 1.2 2.2 40.0 240518×3×1.5 0.7 1.2 2.3 42.0 263019×3×1.5 0.7 1.2 2.3 42.4 271020×3×1.5 0.7 1.2 2.3 43.5 294021×3×1.5 0.7 1.4 2.4 44.9 311023×3×1.5 0.7 1.4 2.5 46.7 340024×3×1.5 0.7 1.4 2.5 47.5 343027×3×1.5 0.7 1.4 2.6 50.0 371030×3×1.5 0.7 1.4 2.7 52.3 406032×3×1.5 0.7 1.4 2.7 53.8 42851×2×2.5 0.7 1.1 1.3 14.5 3352×2×2.5 0.7 1.1 1.5 20.4 7403×2×2.5 0.7 1.1 1.5 21.3 8004×2×2.5 0.7 1.1 1.6 22.8 9305×2×2.5 0.7 1.1 1.6 24.7 1075

Copyright@ Caledonian Câbles Offshore & Marine

Page 80: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

78 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément

× coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

6×2×2.5 0.7 1.1 1.7 26.9 12457×2×2.5 0.7 1.1 1.7 26.9 12908×2×2.5 0.7 1.1 1.8 29.3 14059×2×2.5 0.7 1.1 1.9 31.3 1585

10×2×2.5 0.7 1.2 2.0 33.2 160512×2×2.5 0.7 1.2 2.0 34.0 174514×2×2.5 0.7 1.2 2.0 35.6 192015×2×2.5 0.7 1.2 2.2 38.8 220516×2×2.5 0.7 1.2 2.2 39.4 223018×2×2.5 0.7 1.2 2.3 41.5 250019×2×2.5 0.7 1.2 2.3 41.9 259020×2×2.5 0.7 1.2 2.3 43.5 281521×2×2.5 0.7 1.4 2.4 45.2 299023×2×2.5 0.7 1.4 2.4 45.8 321524×2×2.5 0.7 1.4 2.5 48.2 327027×2×2.5 0.7 1.4 2.6 49.4 351530×2×2.5 0.7 1.4 2.6 51.0 381033×2×2.5 0.7 1.4 2.7 53.1 414537×2×2.5 0.7 1.4 2.8 54.9 45001×3×2.5 0.7 1.1 1.3 15.1 3852×3×2.5 0.7 1.1 1.5 22.0 8803×3×2.5 0.7 1.1 1.6 23.0 9904×3×2.5 0.7 1.1 1.6 24.6 11505×3×2.5 0.7 1.1 1.7 26.9 13506×3×2.5 0.7 1.1 1.8 30.0 15957×3×2.5 0.7 1.1 1.8 30.0 16708×3×2.5 0.7 1.1 1.9 32.2 18209×3×2.5 0.7 1.2 2.0 34.8 2105

10×3×2.5 0.7 1.2 2.1 37.9 219012×3×2.5 0.7 1.2 2.2 39.2 245514×3×2.5 0.7 1.2 2.2 40.9 271515×3×2.5 0.7 1.2 2.3 42.3 290516×3×2.5 0.7 1.2 2.3 43.5 306018×3×2.5 0.7 1.4 2.4 46.1 338019×3×2.5 0.7 1.4 2.5 46.7 353020×3×2.5 0.7 1.4 2.5 47.9 380021×3×2.5 0.7 1.4 2.5 48.9 395023×3×2.5 0.7 1.4 2.6 50.9 429024×3×2.5 0.7 1.4 2.6 51.8 432527×3×2.5 0.7 1.4 2.7 54.5 474530×3×2.5 0.7 1.6 2.9 57.7 530032×3×2.5 0.7 1.6 2.9 59.3 5595

Copyright@ Caledonian Câbles Offshore & Marine

Page 81: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

79ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S13 BU(i) 250 V

Applications

Ces câbles sont résistants au feu, retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Blindage individuel : Chaque paires/triples sont examinées par ruban de polyester

soutenue en cuivre en contact avec un fil de drain en cuivre étamé toronné et enveloppé avec du ruban adhésif polyester. Couples/triples sont numérotés avec un ruban numéroté ou par numéros imprimés directement sur les conducteurs isolés.

Gaine extérieure: Composés thermodurcissables libre d’halogène, SHF2, couleur gris (bleu pour sécurité intrinsèque).

Ruban Mica + HFEPR Isolation

Conducteur En Cuivre Multibrins

SHF2 Gaine

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 82: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

80 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5 2.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6 2.0Maximum résistant@20℃ Ω/km 26.3 19.3 12.9 8.02Capacité mutuelle nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Tension de fonctionnement V 250 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×2×0.75 0.6 1.0 8.2 1052×2×0.75 0.6 1.2 10.5 2054×2×0.75 0.6 1.2 13.2 2907×2×0.75 0.6 1.4 16.0 4458×2×0.75 0.6 1.4 17.3 49512×2×0.75 0.6 1.6 21.1 70516×2×0.75 0.6 1.7 23.5 91519×2×0.75 0.6 1.8 24.8 103524×2×0.75 0.6 1.9 28.6 132032×2×0.75 0.6 2.0 31.7 16701×3×0.75 0.6 1.0 8.6 1202×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.8 3004×3×0.75 0.6 1.3 15.1 3657×3×0.75 0.6 1.5 18.3 5608×3×0.75 0.6 1.5 19.5 65012×3×0.75 0.6 1.7 24.4 91516×3×0.75 0.6 1.8 27.3 118519×3×0.75 0.6 1.9 29.0 136024×3×0.75 0.6 2.1 33.7 1750

Copyright@ Caledonian Câbles Offshore & Marine

Page 83: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

81ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×2×1.0 0.6 1.0 8.6 1252×2×1.0 0.6 1.2 11.1 2404×2×1.0 0.6 1.3 14.0 3457×2×1.0 0.6 1.5 16.9 5258×2×1.0 0.6 1.5 18.5 600

12×2×1.0 0.6 1.6 22.3 84016×2×1.0 0.6 1.6 24.9 109519×2×1.0 0.6 1.8 26.5 125524×2×1.0 0.6 1.9 30.5 160532×2×1.0 0.6 2.0 33.8 20301×3×1.0 0.6 1.0 9.1 1403×3×1.0 0.6 1.3 14.7 3604×3×1.0 0.6 1.3 16.1 4407×3×1.0 0.6 1.6 19.7 695

12×3×1.0 0.6 1.7 26.0 111516×3×1.0 0.6 1.8 29.2 145519×3×1.0 0.6 1.9 31.0 167524×3×1.0 0.6 2.1 36.1 21451×2×1.5 0.7 1.0 9.6 1552×2×1.5 0.7 1.3 12.6 3104×2×1.5 0.7 1.4 16.1 4507×2×1.5 0.7 1.6 19.4 6908×2×1.5 0.7 1.6 21.3 780

12×2×1.5 0.7 1.7 25.7 110016×2×1.5 0.7 1.9 28.9 145019×2×1.5 0.7 2.0 30.5 164524×2×1.5 0.7 2.2 35.3 211532×2×1.5 0.7 2.3 39.1 26801×3×1.5 0.7 1.1 10.1 1752×3×1.5 0.7 1.3 14.5 3203×3×1.5 0.7 1.3 16.8 4704×3×1.5 0.7 1.4 18.4 5807×3×1.5 0.7 1.7 22.6 9108×3×1.5 0.7 1.7 23.5 1030

12×3×1.5 0.7 1.9 30.0 147516×3×1.5 0.7 2.0 33.6 192519×3×1.5 0.7 2.1 35.7 221024×3×1.5 0.7 2.4 41.7 28551×2×2.5 0.7 1.1 10.5 1901×3×2.5 0.7 1.3 11.0 220

Copyright@ Caledonian Câbles Offshore & Marine

Page 84: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

82 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S14 BU(c) 250 V

Applications

Ces câbles non blindés sont résistants au feu, retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Collectives Blindage: Paires / triples sont layed et collectivement projetés par le

cuivre soutenu polyester bande en contact avec un fil de continuité étamé en cuivre brin. Paires / triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés.

Gaine extérieure: Composés thermodurcissables libre d’halogène, SHF2, couleur gris (bleu pour sécurité intrinsèque).

Ruban Mica + HFEPR Isolation

Conducteur En Cuivre Multibrins

SHF2 Gaine

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 85: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

83ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Cross Section Nominale Zone mm² 0.75 1.0 1.5Chef d’orchestre Diamètre nominal mm 1.1 1.3 1.6Maximum résistant@20℃ Ω/km 26.3 19.3 12.9Capacité mutuelle nF/km 75 80 85Nominal Inductance@1KHz MH/km 0.727 0.686 0.667Maximum L/R@1KHz μH/Ω 20 25 35Tension de fonctionnement V 250 250 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

2×2×0.75 0.6 1.1 10.2 1854×2×0.75 0.6 1.2 12.5 2407×2×0.75 0.6 1.4 15.0 3508×2×0.75 0.6 1.4 16.3 395

12×2×0.75 0.6 1.5 19.5 54016×2×0.75 0.6 1.6 21.8 69019×2×0.75 0.6 1.7 23.2 78024×2×0.75 0.6 1.8 26.7 98532×2×0.75 0.6 2.1 29.6 12252×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.1 2654×3×0.75 0.6 1.3 14.4 3207×3×0.75 0.6 1.3 17.4 4758×3×0.75 0.6 1.5 19.5 590

12×3×0.75 0.6 1.6 22.9 74516×3×0.75 0.6 1.7 25.6 96519×3×0.75 0.6 1.8 27.2 109524×3×0.75 0.6 2.0 31.6 14052×2×1.0 0.6 1.1 10.7 210

Copyright@ Caledonian Câbles Offshore & Marine

Page 86: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

84 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

4×2×1.0 0.6 1.1 13.3 2857×2×1.0 0.6 1.4 16.0 4158×2×1.0 0.6 1.4 17.3 465

12×2×1.0 0.6 1.6 20.8 64516×2×1.0 0.6 1.7 23.3 82519×2×1.0 0.6 1.8 24.7 94024×2×1.0 0.6 1.9 28.8 120032×2×1.0 0.6 2.3 31.8 14953×3×1.0 0.6 1.2 14.0 3104×3×1.0 0.6 1.4 15.3 3807×3×1.0 0.6 1.6 18.6 570

12×3×1.0 0.6 1.6 24.4 90016×3×1.0 0.6 1.7 27.3 116019×3×1.0 0.6 1.9 29.0 132524×3×1.0 0.6 2.1 33.7 17002×2×1.5 0.7 1.2 12.1 2754×2×1.5 0.7 1.3 15.2 3807×2×1.5 0.7 1.5 18.4 5658×2×1.5 0.7 1.5 20.0 640

12×2×1.5 0.7 1.7 24.3 89516×2×1.5 0.7 1.8 27.2 115019×2×1.5 0.7 1.9 28.6 129524×2×1.5 0.7 2.1 33.5 167032×2×1.5 0.7 2.3 37.0 20952×3×1.5 0.7 1.3 15.0 3103×3×1.5 0.7 1.3 16.0 4204×3×1.5 0.7 1.4 17.7 5157×3×1.5 0.7 1.6 21.5 7858×3×1.5 0.7 1.6 23.5 930

12×3×1.5 0.7 1.8 28.5 125516×3×1.5 0.7 1.9 31.9 163019×3×1.5 0.7 2.0 33.8 185524×3×1.5 0.7 2.2 39.3 2375

Copyright@ Caledonian Câbles Offshore & Marine

Page 87: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

85ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S15 BFOU-HCF(i) 250 V

Applications

Ces câbles sont résistantes au feu, retardateur de flamme, sans fumée et halogènes, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme d'urgence nécessitant d'être opérationnel durant une 1100 ℃ feu d'hydrocarbures.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil recuit circulaire conserves brin de cuivre CEI 60228 classe 2. Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Blindage individuel : Chaque paires/triples sont examinées par ruban de polyester

soutenue en cuivre en contact avec un fil de drain en cuivre étamé toronné et enveloppé avec du ruban adhésif polyester. Couples/triples sont numérotés avec un ruban numéroté ou par numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure1: Halogène composé thermodurcissable libre, SHF2. Protection contre l’incendie-HC :Protection contre l’incendie thermoplastique

SHF2 Gaine

Ruban Mica + HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF1 Gaine

HC-Protection Contre L'incendie+Ruban AdhésifFil De Cuivre Ètamé

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 88: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

86 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

composé des profilés extrudés.. Enregistrement :Ruban de fibre de verre rodé. Gaine extérieure2: Thermoplastique ignifuge sans halogène composé, tapez SHF1,

couleur gris (bleu pour sécurité intrinsèque).

Caractéristiques électriques

Cross Section Nominale Zone mm² 1.5Chef d’orchestre Diamètre nominal mm 1.6Maximum résistant@20℃ Ω/km 12.9Capacité mutuelle nF/km 100Nominal Inductance@1KHz MH/km 0.673Tension de fonctionnement V 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 12×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des

carottes en élément × coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal cours

Literiemm

Diamètre nominal sur gaine1

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×2×1.5 0.7 9.0 13.1 39.5 18802×2×1.5 0.7 13.0 16.8 44.5 24504×2×1.5 0.7 15.0 20.7 47.5 28308×2×1.5 0.7 21.0 26.4 54.0 3690

12×2×1.5 0.7 25.0 31.2 63.0 5200

Copyright@ Caledonian Câbles Offshore & Marine

Page 89: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

87ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S16 BFOU-HCF(c) 250 V

Applications

Ces câbles sont résistantes au feu, retardateur de flamme, sans fumée et halogènes, utilisé pour les systèmes d'instrumentation, de communication, de contrôle et d'alarme d'urgence nécessitant d'être opérationnel durant une 1100 ℃ feu d'hydrocarbures.

Normes

IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Fil de cuivre étamé brin circulaire IEC 60228 classe 2 Isolation: Ruban Mica + Halogène composé EPR libre. Jumelage : Code couleurs carottes torsadés ensemble. Collectives Blindage: Paires / triples sont layed et collectivement projetés par le

cuivre soutenu polyester bande en contact avec un fil de continuité étamé en cuivre brin. Paires / triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés.

Literie: Composé sans halogène. Armour: Fil de cuivre étamé tresse. Gaine extérieure1: Halogène composé thermodurcissable libre, SHF2. Protection contre l’incendie-HC :Protection contre l’incendie thermoplastique

SHF2 Gaine

Ruban Mica + HFEPR Isolation

Literie Sans Halogène

Conducteur En Cuivre Multibrins

SHF1 Gaine

HC-Protection Contre L'incendie+Ruban AdhésifFil De Cuivre Ètamé

Ruban De Cuivre/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 90: Caledonian Câbles Offshore & Marine NORME NEK606

Résistant Au Feu Câbles Instrumentation

88 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

composé des profilés extrudés.. Enregistrement :Ruban de fibre de verre rodé. Gaine extérieure2: Thermoplastique ignifuge sans halogène composé, tapez SHF1,

couleur gris (bleu pour sécurité intrinsèque).

Caractéristiques électriques Cross Section Nominale Zone mm² 1.5Chef d’orchestre Diamètre nominal mm 1.6Maximum résistant@20℃ Ω/km 12.9Capacité mutuelle nF/km 85Nominal Inductance@1KHz MH/km 0.667Tension de fonctionnement V 250

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 12×OD (fixes installés) Plage de température: -20℃ ~ +90℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

coupe transversale(mm²)

Épaisseur D'isolation Nominale

mm

Diamètre nominal cours

Literiemm

Diamètre nominal sur

gaine1mm

Diamètre nominal global

mm

Poids nominalkg/km

2×2×1.5 0.7 13.0 16.4 44.5 24004×2×1.5 0.7 15.0 19.9 46.5 26508×2×1.5 0.7 20.5 25.3 53.0 3570

12×2×1.5 0.7 23.5 29.6 57.0 4160

Copyright@ Caledonian Câbles Offshore & Marine

Page 91: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Télécommunications

89ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S9 IYXI(c) 60 V

Applications

Ces câbles sont retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les télécommunications à l'intérieur.

Normes

IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Solide cuivre étamé, 0.5mm. Isolation: PE composé thermoplastique sans halogène. Jumelage : Codés par couleur noyaux torsadés. Les couples sont croix-brin au câble

fini ou 10 unités de paire. Les unités sont bloqués à 20 ans - 30 - 50 câbles à paires. 2 paire est bloqué comme un quad étoiles.

Emballage:Ruban de polyester. Collectives Blindage: L’âme du câble est projeté par le cuivre soutenu ruban

polyester en contact avec un fil de 0,5 mm de vidange étamé solide. Gaine:Composé thermoplastique sans halogène, le type SHF1, de couleur grise.

Caractéristiques électriques

Chef d’orchestre Diamètre nominal mm 0.5Maximum résistant@20℃ Ω/km 95Nominal Inductance@1KHz MH/km 0.61Capacité mutuelle câble 1 paire nF/km 90

Ruban De Cuivre/Polyester+Fil De Drain

Isolation PE Gratuit Halogène

Ruban D'emballage

Conducteur De Cuivre Massif

SHF1 Gaine

Paire Torsadée

Copyright@ Caledonian Câbles Offshore & Marine

Page 92: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Télécommunications

90 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Capacité mutuelle câble 2 paires nF/km 80Capacité mutuelle 4 paires et au-dessus de câble nF/km 70

Tension de fonctionnement V 60

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -10℃ ~ +60℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

Diamètre du noyau(mm)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gaine

mm

Diamètre nominal globalmm

Poids nominalkg/km

1×2×0.5 0.2 1.2 5.0 302×2×0.5 0.2 1.2 5.5 354×2×0.5 0.2 1.2 7.0 55

10×2×0.5 0.2 1.5 8.5 9020×2×0.5 0.2 1.5 11.0 14830×2×0.5 0.2 1.5 13.5 21050×2×0.5 0.2 1.5 16.0 320

Copyright@ Caledonian Câbles Offshore & Marine

Page 93: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Télécommunications

91ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

S10 IYOI(c) 60 V

Applications

Ces câbles sont retardateur de flamme, faible dégagement de fumée et sans halogène, utilisé pour les télécommunications à l'intérieur.

Normes

IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: Solide cuivre étamé, 0.5mm. Isolation: PE composé thermoplastique sans halogène. Jumelage : Noyaux Couleur codés tordus ensemble.Les couples sont croix-brin au

câble fini ou 10 unités de paire.Les unités sont bloqués à 20 ans - 30 - 50 câbles à paires.2 paire est bloqué comme un quad étoiles.

Emballage:Ruban de polyester. Collectives Blindage: L’âme du câble est projeté par le cuivre soutenu ruban

polyester en contact avec un fil de 0,5 mm de vidange étamé solide. Literie: Composé thermoplastique sans halogène, le type SHF1, de couleur grise. Armour: Fil De Cuivre Ètamé Gaine extérieure: Composé thermoplastique sans halogène, le type SHF1, de couleur

grise.

Caractéristiques électriques

Chef d’orchestre Diamètre nominal mm 0.5Maximum résistant@20℃ Ω/km 95

Ruban De Cuivre/Polyester+Fil De Drain

Isolation PE Gratuit HalogèneRuban D'emballage

SHF1 Gaine

Conducteur De Cuivre Massif

SHF1 Gaine

Fil De Cuivre Ètamé

Copyright@ Caledonian Câbles Offshore & Marine

Page 94: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Télécommunications

92 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Nominal Inductance@1KHz MH/km 0.61Capacité mutuelle câble 1 paire nF/km 90Capacité mutuelle câble 2 paires nF/km 80Capacité mutuelle 4 paires et au-dessus de câble nF/km 70

Tension de fonctionnement V 60

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 6×OD (fixes installés) Plage de température: -10℃ ~ +60℃

Dimensions et poids

Construction de no des éléments × non. des carottes en élément ×

Diamètre du noyau(mm)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur1×2×0.5 0.2 1.2 1.2 8.0 952×2×0.5 0.2 1.2 1.2 9.0 1104×2×0.5 0.2 1.2 1.2 10.0 14510×2×0.5 0.2 1.5 1.5 12.0 20020×2×0.5 0.2 1.5 1.5 15.0 33030×2×0.5 0.2 1.5 1.5 17.0 43050×2×0.5 0.2 1.5 1.5 20.0 580

Copyright@ Caledonian Câbles Offshore & Marine

Page 95: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

93ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

F1 QFCI

Applications

Ces acier câbles à fibres optiques blindées sont ignifuge, sans fumée, halogènes libres et résistant au feu, utilisé pour la communication et des systèmes d'urgence qui doivent être opérationnelles au cours de l'incendie.

Normes

IEC 60794 IEC 60811-2-1 IEC 60331-25 IEC 60332-3-24 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Élément De Fibre: En vrac conception du cœur du tube. Élément central de la force : Fil d’acier ou de fibre renforcée plastique (FRP). Literie: Halogène composé thermoplastique ignifuge libre et des flammes. Armour: Tresse en acier galvanisé. Gaine extérieure: Sans halogène et retardateur de flamme, composé thermoplastique

stabilisé aux UV, SHF1.

Facultatif

F4 QFCI-HCF: Câbles QFCI-HCF sont composent de lâche élément de fibre de tube, fil d'acier ou de PRF élément de la force centrale, halogène retardateur literie thermoplastique sans flamme et, du fil galvanisé tresse armure d'acier, SHF1 gaine, la protection HC-le-feu, la bande résistant au feu et SHF1 gaine extérieure.

Tresse De Fil D'acier Galvanisé Á

Fil D'acier/ FRP Élément De Force

Literie Sans Halogène

Élément De Fibre

SHF1 Gaine

Copyright@ Caledonian Câbles Offshore & Marine

Page 96: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

94 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

Type de fibre 9/125 50/125 50/125 62.5/125Type de ITU-T G652.D G651 G651 -IEC11801 Classement OS1 & OS2 OM2 OM3 OM1Diamètre du noyau μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Diamètre de la gaine μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Diamètre de revêtement μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Atténuation maximale

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Bande passante minimum(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum de Dispersion chromatique1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zéro longueur d’onde de Dispersion nm 1300~1324 - - -

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 10×OD (fixes installés) Plage de température: -40℃ ~ +70℃

Dimensions et poids

No. de Fibres

Construction de no. des tubes×No. des fibres dans chaque

tube

Nombre de chargesNominale vrac Tube

Diamètremm

Diamètre nominal globalmm

Poids nominalkg/km

2 1×2 5 2.2 13.9 2444 1×4 5 2.2 13.9 2446 3×2 3 2.2 13.9 2448 2×4 4 2.2 13.9 24410 5×2 1 2.2 13.9 24412 3×4 3 2.2 13.9 24416 4×4 2 2.2 13.9 24420 5×4 1 2.2 13.9 24424 6×4 0 2.2 13.9 24432 4×8 2 2.2 13.9 24440 5×8 1 2.2 13.9 24448 6×8 0 2.2 13.9 244

Copyright@ Caledonian Câbles Offshore & Marine

Page 97: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

95ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

F5 QFCB

Applications

Ces acier câbles à fibres optiques blindées sont ignifuge, sans fumée, halogènes libres et résistant au feu, utilisé pour la communication et des systèmes d'urgence qui doivent être opérationnelles au cours de l'incendie.

Normes

IEC 60794 IEC 60811-2-1 IEC 60331-25 IEC 60332-3-24 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Élément De Fibre: En vrac conception du cœur du tube. Élément central de la force : Fil d’acier ou de fibre renforcée plastique (FRP). Literie: Halogène composé thermoplastique ignifuge libre et des flammes. Armour: Tresse en acier galvanisé. Gaine extérieure1: Sans halogène et retardateur de flamme, composé

thermoplastique stabilisé aux UV, SHF1. Gaine extérieure2: Résistant à la boue et halogène thermoplastique composé.

Caractéristiques électriques

Type de fibre 9/125 50/125 50/125 62.5/125Type de ITU-T G652.D G651 G651 -IEC11801 Classement OS1 & OS2 OM2 OM3 OM1

Diamètre du noyau μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0

Tresse De Fil D'acier Galvanisé Á

Fil D'acier/ FRP Élément De ForceLiterie Sans Halogène

Élément De Fibre

SHF1 Gaine

Mud Résistant & Halogène Gaine Gratuit

Copyright@ Caledonian Câbles Offshore & Marine

Page 98: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

96 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Diamètre de la gaine μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Diamètre de revêtement μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Atténuation maximale

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Bande passante minimum(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum de Dispersion chromatique1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zéro longueur d’onde de Dispersion nm 1300~1324 - - -

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 10×OD (fixes installés) Plage de température: -40℃ ~ +70℃

Dimensions et poids

No. de Fibres

Construction de no. des tubes×No. des fibres dans chaque

tube

Nombre de chargesNominale vrac Tube

Diamètremm

Diamètre nominal globalmm

Poids nominalkg/km

2 1×2 5 2.2 15.0 2904 1×4 5 2.2 15.0 2906 3×2 3 2.2 15.0 2908 2×4 4 2.2 15.0 29010 5×2 1 2.2 15.0 29012 3×4 3 2.2 15.0 29016 4×4 2 2.2 15.0 29020 5×4 1 2.2 15.0 29024 6×4 0 2.2 15.0 29032 4×8 2 2.2 15.0 29040 5×8 1 2.2 15.0 29048 6×8 0 2.2 15.0 290

Copyright@ Caledonian Câbles Offshore & Marine

Page 99: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

97ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

F6 AICI

Applications

Ces câbles à fibres optiques sont résistantes au feu, retardateur de flamme, sans fumée et halogènes, utilisés pour les systèmes d'instrumentation, de données et de communication.

Normes

IEC 60794 IEC 60811-2-1 IEC 60331-25 IEC 60332-3-24 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Élément de fibre : Tamponnée serré fibres. Élément de Force centrale: plastique renforcé de fibres (PRF) et / ou des fils

d’aramide. Literie: Halogène composé thermoplastique ignifuge libre et des flammes. Armour: Tresse en acier galvanisé. Gaine extérieure: Sans halogène et retardateur de flamme, composé thermoplastique

stabilisé aux UV, SHF1.

Caractéristiques électriques

Type de fibre 9/125 50/125 50/125 62.5/125Type de ITU-T G652.D G651 G651 -IEC11801 Classement OS1 & OS2 OM2 OM3 OM1

Diamètre du noyau μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0

Tresse De Fil D'acier Galvanisé Á

Aramide Fils

Literie Sans Halogène

Élément De Fibre

SHF1 Gaine

Copyright@ Caledonian Câbles Offshore & Marine

Page 100: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Fibre Optique

98 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Diamètre de la gaine μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Diamètre de revêtement μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Atténuation maximale

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Bande passante minimum(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum de Dispersion chromatique1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zéro longueur d’onde de Dispersion nm 1300~1324 - - -

Propriétés mécaniques et thermiques

Rayon de cintrage: 20×OD (lors de l’installation); 10×OD (fixes installés) Plage de température: -40℃ ~ +70℃

Dimensions et poids

No. de FibresRevêtement secondaire

mmDiamètre nominal global

mmPoids nominal

kg/km

2 0.9 7.8 1004 0.9 8.2 1108 0.9 9.4 125

12 0.9 10.3 14524 0.9 12.0 185

Copyright@ Caledonian Câbles Offshore & Marine

Page 101: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

99ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Cat5E UTP/FTP Blindé câble de données

Applications

Cat5E câble est un câble standard pour Gigabit Ethernet et d'autres protocoles de réseau, adapté aux voix et données de base des installations jusqu'à 100 MHz.En outre, ces câbles sont avec du fil de cuivre tresse boue ignifuge blindé et résistant à la flamme gaine extérieure, offrant une protection mécanique supplémentaire en conservant la flexibilité du câble.

Normes

IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 24AWG cuivre nu solide. Isolation: HDPE. Jumelage: Deux conducteurs isolés torsadés ensemble de couleurs pour former une

paire. Literie: Polyoléfine ignifuge, peu de fumée et sans halogène, couleur noir. Armour: 0.2/0.3mm fil de cuivre tresse. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Facultatif

Cat5E F/UTP: Ces câbles ont un blindage collectif de ruban aluminium/Polyester avec fil de drain.

Cat5E SF/UTP: Ces câbles ont blindages doubles collectives de ruban aluminium / polyester et fil de cuivre tresse avec fil de drain.

Fil De Cuivre Ètamé

HDPE Isolation

FRLSZH Literie Polyoléfine

Conducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Paire Torsadée

Copyright@ Caledonian Câbles Offshore & Marine

Page 102: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

100 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

AWG 24Chef d’orchestre Diamètre nominal mm 0.53Resistant@20℃ DC maximale Ω/100m 9.38DCR maximale Déséquilibre % 5Capacité maximale mutuelle pF/m 55.8Déséquilibre de capacité maximale pF/100m 330Impédance caractéristique@1-100MHz Ω 100+/-15Maximum Délai de propagation d’obliquité ns/100m 45

FREQMHz

Atténuation maximaledB/100m

Minimale NEXT

dB

Minimale PSNEXT

dB

Minimale ELFEXTdB/100m

Minimale PSELFEXTdB/100m

Minimale RLdB

0.772 1.8 67.0 64.0 66.0 63.0 —1 2.0 65.3 62.3 63.8 60.8 20.04 4.1 56.3 53.3 51.7 48.7 23.08 5.8 51.8 48.8 45.7 42.7 24.510 6.5 50.3 47.3 43.8 40.8 25.016 8.2 47.3 44.3 39.7 36.7 25.020 9.3 45.8 42.8 37.7 34.7 25.025 10.4 44.3 41.3 35.8 32.8 24.3

31.25 11.7 42.9 39.9 33.9 30.9 23.662.5 17.0 38.4 35.4 27.8 24.8 21.5100 22.0 35.3 32.3 23.8 20.8 20.1

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 4×OD (fixes installés) Plage de température: -30℃ ~ +75℃

Fil De Cuivre Ètamé

HDPE Isolation

FRLSZH Literie Polyoléfine

Conducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Ruban De AL/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 103: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

101ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Dimensions et poids

Travaux Nombre d' éléments×Nombre de noyaux dans l'élément×Diamètre du

conducteur(mm)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

4×2×0.53 0.2 0.8 1.14 10.1 179

Copyright@ Caledonian Câbles Offshore & Marine

Page 104: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

102 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Cat6 UTP/FTP Blindé câble de données

Applications

Câble CAT6 est un câble standard pour Gigabit Ethernet et l'autre protocole réseau utilisable pour 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet). En outre, ces câbles sont avec du fil de cuivre tresse blindée & ignifuge résistant à la boue gaine externe, fournissant supplémentaires mécaniquement protection en conservant la flexibilité du câble.

Normes

IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 23AWG nu en cuivre massif. Isolation: HDPE. Jumelage: Deux conducteurs isolés torsadés ensemble de couleurs pour former une

paire. Literie: Polyoléfine ignifuge, peu de fumée et sans halogène, couleur noir. Armour: 0.2/0.3mm de fil de cuivre tresse. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Facultatif

Cat6 F/UTP: Ces câbles ont un blindage collectif de ruban aluminium/Polyester avec fil de drain.

Cat6 SF/UTP: Ces câbles ont blindages doubles collectives de ruban aluminium / polyester et fil de cuivre tresse avec fil de drain.

Fil De Cuivre Ètamé

HDPE IsolationFRLSZH Literie Polyoléfine

Conducteur De Cuivre MassifLSZH Gaine Polyoléfine

Paire Torsadée

Copyright@ Caledonian Câbles Offshore & Marine

Page 105: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

103ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques électriques

AWG 23Chef d’orchestre Diamètre nominal mm 0.58Resistant@20℃ DC maximale Ω/100m 7.5DCR maximale Déséquilibre % 3Capacité maximale mutuelle pF/m 5.6Déséquilibre de capacité maximale pF/100m 330Impédance caractéristique@1-100MHz Ω 100+/-15Maximum Délai de propagation d’obliquité ns/100m 18

FREQMHz

Atténuation maximaledB/100m

Minimale NEXT

dB

Minimale PSNEXT

dB

Minimale ELFEXTdB/100m

Minimale PSELFEXTdB/100m

Minimale RLdB

0.772 1.8 76.0 74.0 70.0 67.0 —1 2.0 74.3 72.3 67.8 64.8 20.04 3.8 65.3 63.3 55.7 52.7 23.08 5.3 60.8 58.8 49.7 46.7 24.5

10 6.0 59.3 57.3 47.8 44.8 25.016 7.6 56.3 54.3 43.7 40.7 25.020 8.5 54.8 52.8 41.7 38.7 25.025 9.5 53.3 51.3 39.8 36.8 24.3

31.25 10.7 51.9 49.9 37.9 34.9 23.662.5 15.4 47.4 45.4 31.8 28.8 21.5100 19.8 44.3 42.3 27.8 24.8 20.1155 25.2 41.5 39.5 23.9 20.9 18.8200 29.0 39.8 37.8 21.7 18.7 18.0250 32.8 38.3 36.3 19.8 16.8 17.3

Fil De Cuivre Ètamé

HDPE Isolation

FRLSZH Literie Polyoléfine

Conducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Ruban De AL/Polyester+Fil De Drain

Copyright@ Caledonian Câbles Offshore & Marine

Page 106: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles De Données

104 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Propriétés mécaniques et thermiques

Rayon de cintrage: 8×OD (lors de l’installation); 4×OD (fixes installés) Plage de température: -30℃ ~ +75℃

Dimensions et poids

Travaux Nombre d' éléments×Nombre de noyaux dans l'élément×Diamètre du

conducteur(mm)

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal global

mm

Poids nominalkg/km

Intérieure Extérieur

4×2×0.58 0.23 0.8 1.14 11.6 214

Copyright@ Caledonian Câbles Offshore & Marine

Page 107: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

105ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG6 Câble Coaxial Blindé

Applications

Ces câbles coaxiaux 75Ω conviennent à l'installation à bord des navires et des autres milieux marins à l'intérieur.

Normes

IEC 60092-350 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 18AWG cuivre nu solide. Isolation: Mousse PE. Blindage1: Al/Polyester/Al bande. Blindage2: Tresse en cuivre étamé. Literie: Faible dégagement de fumée et de polyoléfine sans halogène, de couleur

noire. Armour: Fil De Cuivre Ètamé. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Caractéristiques électriques

AWG 18Chef d’orchestre Diamètre nominal mm 1.0Impédance Ω 75+/-5 Atténuation nominale@100MHz dB/100m 6.9Atténuation nominale@200MHz dB/100m 9.0Atténuation nominale@300MHz dB/100m 11.8Atténuation nominale@400MHz dB/100m 13.1

Fil De Cuivre ÉtaméMousse PE Isolation

Tresse En Cuivre ÉtaméConducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Al/Polyester/Al BandeLSZH Literie Polyoléfine

Copyright@ Caledonian Câbles Offshore & Marine

Page 108: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

106 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Atténuation nominale@500MHz dB/100m 15.4Atténuation nominale@900MHz dB/100m 21.5Atténuation nominale@1700MHz dB/100m 29.4Capacitance pF/m 53.5Vitesse de propagation % 83Chef d’orchestre DCR Ω/km 21.4Bouclier DCR Ω/km 7.5Inductance μH/m 0.32Temps de retard ns/m 4

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD Plage de température: -30℃ ~ +75℃

Dimensions et poids

Nominaux intérieure Diamètre du conducteur

mm

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1.0 1.8 1.2 11.2 208

Copyright@ Caledonian Câbles Offshore & Marine

Page 109: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

107ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG11 Câble Coaxial Blindé

Applications

Ces câbles coaxiaux 75Ω conviennent à l'installation à bord des navires et des autres milieux marins à l'intérieur.

Normes

IEC 60092-350 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 14AWG cuivre nu solide. Isolation: Mousse PE. Blindage1: Al/Polyester/Al bande. Blindage2: Tresse en cuivre étamé. Literie: Faible dégagement de fumée et de polyoléfine sans halogène, de couleur

noire. Armour: Fil De Cuivre Ètamé. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Caractéristiques électriques

AWG 14Chef d’orchestre Diamètre nominal mm 1.6Impédance Ω 75+/-5 Atténuation nominale@100MHz dB/100m 4.5Atténuation nominale@270MHz dB/100m 7.6Atténuation nominale@540MHz dB/100m 10.8Atténuation nominale@750MHz dB/100m 12.8

Fil De Cuivre ÉtaméMousse PE Isolation

Tresse En Cuivre ÉtaméConducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Al/Polyester/Al BandeLSZH Literie Polyoléfine

Copyright@ Caledonian Câbles Offshore & Marine

Page 110: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

108 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Atténuation nominale@1000MHz dB/100m 14.8Capacitance pF/m 53.5Vitesse de propagation % 83Chef d’orchestre DCR Ω/km 8.5Bouclier DCR Ω/km 12.1Inductance μH/m 0.32Temps de retard ns/m 4

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD Plage de température: -30℃ ~ +75℃

Dimensions et poids

Nominaux intérieure Diamètre du conducteur

mm

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

1.6 2.7 1.7 15.0 353

Copyright@ Caledonian Câbles Offshore & Marine

Page 111: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

109ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG59 Câble Coaxial Blindé

Applications

Ces câbles coaxiaux 75Ω conviennent à l'installation à bord des navires et des autres milieux marins à l'intérieur.

Normes

IEC 60092-350 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 20AWG cuivre nu solide. Isolation: Mousse PE. Blindage1: Al/Polyester/Al bande. Blindage2: Tresse en cuivre étamé. Literie: Faible dégagement de fumée et de polyoléfine sans halogène, de couleur

noire. Armour: Fil De Cuivre Ètamé. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Caractéristiques électriques

AWG 20Chef d’orchestre Diamètre nominal mm 0.8Impédance Ω 75+/-5 Atténuation nominale@100MHz dB/100m 7.6Atténuation nominale@270MHz dB/100m 12.5Atténuation nominale@540MHz dB/100m 17.9Atténuation nominale@720MHz dB/100m 20.9

Fil De Cuivre ÉtaméMousse PE Isolation

Tresse En Cuivre ÉtaméConducteur De Cuivre Massif

LSZH Gaine Polyoléfine

Al/Polyester/Al BandeLSZH Literie Polyoléfine

Copyright@ Caledonian Câbles Offshore & Marine

Page 112: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

110 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Atténuation nominale@750MHz dB/100m 21.3Atténuation nominale@1000MHz dB/100m 24.9Capacitance pF/m 53.5Vitesse de propagation % 83Chef d’orchestre DCR Ω/km 32.8Bouclier DCR Ω/km 12.5Inductance μH/m 0.318Temps de retard ns/m 4.0

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD Plage de température: -30℃ ~ +75℃

Dimensions et poids

Nominaux intérieure Diamètre du conducteur

mm

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

0.8 1.4 1.2 10.0 177

Copyright@ Caledonian Câbles Offshore & Marine

Page 113: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

111ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG58 Câble Coaxial Blindé

Applications

Ces câbles coaxiaux de 50Ω ne conviennent pas pour l'installation à bord des navires et autres environnements maritimes intérieurs.

Normes

IEC 60092-350 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 21AWG cuivre étamé. Isolation: PE. Blindage: Tresse en cuivre étamé. Literie: Faible dégagement de fumée et de polyoléfine sans halogène, de couleur

noire. Armour: Fil De Cuivre Ètamé. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Caractéristiques électriques

AWG 21Chef d’orchestre construction No/diamètre des fils -/mm 19/0.18Chef d’orchestre Diamètre nominal mm 0.89Impédance Ω 50+/-3 Atténuation nominale@100MHz dB/100m 15.7Atténuation nominale@200MHz dB/100m 22.3Atténuation nominale@400MHz dB/100m 32.8Atténuation nominale@700MHz dB/100m 46.6Atténuation nominale@900MHz dB/100m 54.1

Fil De Cuivre Étamé

PE Isolation

Tresse En Cuivre Étamé

Conducteur En Cuivre Multibrins

LSZH Gaine Polyoléfine

LSZH Literie Polyoléfine

Copyright@ Caledonian Câbles Offshore & Marine

Page 114: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

112 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Atténuation nominale@1000MHz dB/100m 56.1Capacitance pF/m 101Vitesse de propagation % 66Chef d’orchestre DCR Ω/km 35.4Inductance μH/m 0.246Temps de retard ns/m 5.0

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD Plage de température: -30℃ ~ +75℃

Dimensions et poids

Nominaux intérieure Diamètre du conducteur

mm

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

0.89 1.0 1.14 8.6 149

Copyright@ Caledonian Câbles Offshore & Marine

Page 115: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

113ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

RG213 Câble Coaxial Blindé

Applications

Ces câbles coaxiaux de 50Ω ne conviennent pas pour l'installation à bord des navires et autres environnements maritimes intérieurs.

Normes

IEC 60092-350 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

Conducteurs: 13AWG cuivre étamé. Isolation: PE. Blindage: Tresse en cuivre étamé. Literie: Faible dégagement de fumée et de polyoléfine sans halogène, de couleur

noire. Armour: Fil De Cuivre Ètamé. Gaine extérieure: Faible dégagement de fumée et de polyoléfine sans halogène.

Caractéristiques électriques

AWG 13Chef d’orchestre construction No/diamètre des fils -/mm 7/0.75Chef d’orchestre Diamètre nominal mm 2.24Impédance Ω 50+/-3 Atténuation nominale@100MHz dB/100m 7.5Atténuation nominale@200MHz dB/100m 10.5Atténuation nominale@400MHz dB/100m 15.1Atténuation nominale@1000MHz dB/100m 29.5Capacitance pF/m 101

Fil De Cuivre Étamé

PE Isolation

Tresse En Cuivre Étamé

Conducteur En Cuivre Multibrins

LSZH Gaine Polyoléfine

LSZH Literie Polyoléfine

Copyright@ Caledonian Câbles Offshore & Marine

Page 116: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

114 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Vitesse de propagation % 66Chef d’orchestre DCR Ω/km 5.7Bouclier DCR Ω/km 3.9Inductance μH/m 0.246Temps de retard ns/m 5.0

Propriétés mécaniques et thermiques

Rayon de cintrage: 15×OD Plage de température: -30℃ ~ +75℃

Dimensions et poids

Nominaux intérieure Diamètre du conducteur

mm

Épaisseur D'isolation Nominale

mm

Épaisseur nominale de gainemm

Diamètre nominal globalmm

Poids nominalkg/km

2.24 2.2 1.14 13.9 379

Copyright@ Caledonian Câbles Offshore & Marine

Page 117: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

115ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Câble Composite résistant à la boue

Applications

Ces câbles composites sont constitués de câble de données et cat6 câble de câble coaxial et alimentation, avec résistant à fil de cuivre tresse blindée et la flamme du pétrole et de boue retardateur gaine extérieure.

Normes

IEC 60092-359 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004

Construction

1) 4×2×0.57mm U/UTP Cat6 Câble de données: Conducteurs: Fil de cuivre nu solide. Isolation: PE. Jumelage: Deux couleurs fils isolés torsadés pour former une paire. Gaine: LSZH ignifuge, de couleur grise

2) RG59 Câble coaxial: Conducteurs: 0.58mm solide fil de cuivre nu. Isolation: PE. Blindage: Bare tresse de fils de cuivre. Gaine: LSZH ignifuge, de couleur grise

3) 3×1.0mm² Câble d'alimentation: Conducteurs: 7/0.44mm fil de cuivre nu brin. Isolation: XLPE. Coloré Bleu, Marron, vert / jaune. Gaine: LSZH ignifuge, de couleur grise

4) Assemblage de l'élément Remplisseur: PP, PVC, PE ou LSZH Matériel.

Fil De Cuivre Étamé

Polyester RubanÉlément Câble Coaxial

Câble D'alimentation Élément

Flame Retardant LSZH Gaine

Élément De Données Par Câble

Flame Retardant LSZH Literie

Copyright@ Caledonian Câbles Offshore & Marine

Page 118: Caledonian Câbles Offshore & Marine NORME NEK606

Câbles Coaxiaux

116 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Emballage:Ruban de polyester. Literie: Retardateur de flamme LSZH. Armour: Fil de cuivre étamé tresse. Gaine extérieure: Résistant aux huiles et la boue, LSZH ignifuge, de couleur grise

Dimensions

Construction du câbleDiamètre nominal de

câble de données mm

Diamètre nominal de câble coaxial

mm

Diamètre nominal de câble d'alimentation

mm

Diamètre nominal globalmm

4×2×0.57mm + RG59 + 3×1.0mm² 6.0 6.2 6.8 21.0

Remarque: Autres construction peut être offert demande de opon.

Copyright@ Caledonian Câbles Offshore & Marine

Page 119: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

117ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Cable Code DésignationUn code de câble de 2 lettres ( 1. et 4. ) ou 4 lettres est utilisé pour décrire la construction.Par exemple:

1ère lettre: Isolation :B: Bande résistant au feu + isolation (sans halogène)R: Caoutchouc d'éthylène-propylène - EPR T: Polyéthylène réticulé XLPE I: Composé thermoplastique (sans halogène) U: Composé thermodurcissable sans halogène EMA ou EVA A: Fibre, tampon serréeQ: Fibre dans tube en vrac

2ème lettre:Gaine interne:F: Literie/revêtement intérieur ou de l'enregistrement (sans halogène)Y: écran (évent. avec PE ou PP) I: Composé thermoplastique (sans halogène) SHF1

3ème lettre:Armour/écran :L: Aluminium (feuilleté à gaine extérieure)X: Aucune armour O: Fil de cuivre étamé (tinned ou nu ) A: Membre de la Force de fil C: Tresse en acier galvanisé

4ème lettre:Gaine extérieure:I: Composé thermoplastique (sans halogène) , SHF1 U: Composé thermodurcissable sans halogène, SHF2 U: La boue sans halogène composé thermodurcissable résistant, SHF Vase B*: La boue sans halogène composé thermoplastique résistant *QFCB uniquement des câbles

Abréviation supplémentaire pour les câbles d'instrumentation: (c): écran collective(i): paire individuelle ou triple écran

RFOU(i)

Copyright@ Caledonian Câbles Offshore & Marine

Page 120: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

118 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Normes et Tests

NEK 606-2004 Câbles pour les installations offshore sans halogène et / ou résistant à la boue

IEC 60092-350 Installations électriques à bord des navires Partie 350: basse tension des câbles d'alimentation de bord

. (Construction générale et les exigences d'essai)IEC 60092-351 Installations électriques à bord des navires Partie 351: Matériaux isolants pour câbles électriques à

bord des naviresIEC 60092-352 Installations électriques à bord des navires Partie 352: Choix et l'installation de câbles électriques pour

les systèmes d'énergie basse tensionIEC 60092-353 Installations électriques à bord des navires Partie 353: Câbles simples et multicœurs à isolement

massif extrudé pour tensions assignées 0,6 / 1 et 1,8 / 3 KVIEC 60092-354 Partie 354: Câbles d'alimentation simples et trois

conducteurs avec isolation solide extrudé pour tensions assignées de 6 KV à 30 KV.

IEC 60092-359 Partie 359: Matériaux de revêtement pour l'alimentation à bord et les câbles de télécommunication

IEC 60092-375 Partie 375: Câbles d'instrumentation générale, contrôle et communication

IEC 60092-376 Partie 376: 150/250 V câbles de contrôle et d'instrumentation Circuits

IEC 60228 Des câbles isolésIEC 60331-11/12/21/25/31 Résistant au feu caractéristiques des câbles électriquesIEC 60332-1/3 Essais des câbles électriques sous condition d'incendie. Partie 1: Essais sur un conducteur ou câble isolé vertical. Partie 3: Essai sur des fils ou câbles en nappes.IEC 60446 Principes fondamentaux et de sécurité pour l'interface

homme-machine, marquage et l'identification. Identification des conducteurs par des couleurs ou des

caractères alphanumériquesIEC 60754-1/2 Essai sur les gaz émis lors de la combustion des câbles

électriques IEC 60811 Méthodes d'essais communes pour les matériaux isolants

et de gainage des câbles électriquesIEC 61034-1/2 Mesure de la densité de la fumée des câbles électriques

brûlant dans des conditions définies. Partie 1: Appareillage d’essai. Partie 2: Méthode d’essai et exigences

Copyright@ Caledonian Câbles Offshore & Marine

Page 121: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

119ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caractéristiques Du Câble

Mud Résistant

Les qualités des matériaux de revêtement pour utilisation dans les zones où les câbles sont exposés aux fluides de forage sont fortement dépendante du type de fluide présent. chaque type de liquide contient des additifs qui peuvent avoir un effet délétère sur le matériau de revêtement.

Selon NEK 606, les câbles résistants de boue ont une gaine de boue SHF qui sont conformes aux exigences de la CEI 60092-359 pour SHF2 et ci-dessous indiquée. Les câbles résistants de boue doivent être conçus avec des composés de revêtement appropriés pour l'installation et le fonctionnement en contact avec de la boue, sauf indication contraire.

Les exigences de test de résistance à la MUD pour les composés de gainage SHF Mud sont les suivantes:

Fluide d'essai Température Durée

Résistance à la traction &

Allongement à la rupture Variation

variation du volume d'houle

Poids augmenter la variation

Mineral type d'huile - IRM 903

100℃ 7 d 30% 30% 30%

Bromure de calcium saumure

(à base d'eau)70℃ 56 d 25% 20% 15%

Carbo mer (à base d'huile)

70℃ 56 d 25% 20% 15%

Résistance à l’huileTous les câbles gainés thermodurcissables doivent être adaptés à une installation de

production de pétrole. Les propriétés de résistance à l'huile doit être démontrée par un test selon IEC 60092-359 SHF2.

IgnifugationLes câbles doivent résister à l’épreuve dans la CEI 60332-3-10 spécifiée, -22, -23, -24,

-25. Fils simples, de la terre et de liaison doivent pouvoir résister à l’essai spécifié dans la norme CEI 60332-1 ou à la CEI 60332-2.

Résistance Au FeuCâbles de résistance au feu doivent être testés selon la norme IEC 60331-11, -12, -21, -25

et -31.

Copyright@ Caledonian Câbles Offshore & Marine

Page 122: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

120 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Hydrocarbures (HCF) résistant au feu

L'acheteur doit spécifier laquelle des courbes ci-dessous dans la figure 1 ou 2 de se conformer à l'épreuve de la FHC.

Le test ne nécessite pas de ventilation pour les 30 ou 60 minutes lorsqu'il est connecté à la tension de fonctionnement. Temps à la dégradation à prendre en considération en accord avec l'autorité de la clientèle ou

Contenu de l’halogène

Tous les câbles doivent être sans halogène selon IEC 60754-1/2.

Émission de fumée

Au cours d’une émission de câble incendie de fumée doit être maintenu à une valeur minimale de 60% selon IEC 61034-1/2.

Fig.1 HC fire curve based on Exxon calcula�ons, which required func�onal security

for 15 minutes

Time in minutes exposed to fire

Fig.2 Interna�onal recognized HC fire curve.

Time in minutes exposed to fire

Tem

pera

ture

in d

eg.C

Tem

pera

ture

in d

eg.C

20

600

820

10001050 1083 1100 1100

20

743

880945

1033 1071 1098 1100

0 10 20 30 40 50 60

0 10 20 30 40 50 60

Copyright@ Caledonian Câbles Offshore & Marine

Page 123: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

121ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Des données électriques

Résistance conducteur

Formule résistance:

[Ω]

p = résistance spécifique, Ω.mm²/mA = zone de conducteur, mm²L = conducteur longueur, m

Résistance en fonction de la température:

R0= résistance à=20℃t = température du conducteur ℃α= 0.00393 pour le cuivre

Notes de court-circuit

Les courants de court-circuit suivantes sont pour les câbles fonctionnent normalement à une température maximale du conducteur de 90°C.

La température théorique qui se pose dans le conducteur lors d'un court-circuit, qui est utilisée comme base du calcul, est 250℃. EPR et XLPE sont capables de résister à des températures de courte durée jusqu'à 250°C.

Les courants de court-circuit pour conducteurs en cuivre indiqués dans le tableau sont des valeurs pour une seconde, pour d'autres durées du courant peut être calculée à partir de la formule suivante:

It=courant de court-ciricut pour t sec.(Amp)l=courant de court-circuit pour un sec.(Amp)t=courte durée de circuit(sec.)La durée du court-circuit sur la base de ces hypothèses doit être comprise entre 0,2 sec.

et 5 sec.

Copyright@ Caledonian Câbles Offshore & Marine

Page 124: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

122 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Zone de conducteur

mm²

Actuelles 1 seconde ampères

Zone de conducteur

mm²

Actuelles 1 seconde ampères

Zone de conducteur

mm²

Actuelles 1 seconde ampères

Zone de conducteur

mm²

Actuelles 1 seconde ampères

1.0 140 10 1400 70 9800 240 336001.5 210 16 2240 95 13300 300 420002.5 350 25 3500 120 16800 400 560004 560 35 4900 150 21000 500 700006 840 50 7000 185 25900 630 88200

Réactance

La réactance d'un câble dans un système d'exploitation alternatif dépend de nombreux facteurs, y compris, en particulier, l'espacement axial entre les conducteurs et la proximité et propriétés magnétiques de charpente métallique adjacente. Le premier est connu pour le câble multipaires, mais peut varier pour câbles unipolaires en fonction de la distance entre eux et leur disposition lors de l'installation.

Réactance de câbles à certaines dispositions de la charpente métallique est à distance calculable et est représenté. Les valeurs sont pour des câbles avec des conducteurs.

La valeur pour un conducteur en forme de secteur doit être pris comme 90% de la valeur calculée. Induction de 2-, 3- et 4- câbles conducteurs est donnée par la formule:

[H/m]a = L'espace axial entre les conducteurs en mm.d = Diamètre du conducteur en mm.Réactance de câbles 2-, 3- et 4-conducteurs est donnée par la formule:

[Ω]f = en fréquence HzL = en Induction H/m I = Longueur de câble en m

Impédance

Induction de 2-, 3- et 4- câbles conducteurs est donnée par la formule:

[Ω]R = Résistance au fonctionnement Temperature dans ΩX = Réactance en Ω

Copyright@ Caledonian Câbles Offshore & Marine

Page 125: Caledonian Câbles Offshore & Marine NORME NEK606

Informations Techniques

123ADDISONwww.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Identification de base L'identification des conducteurs isolés (noyaux) pour les câbles 250 V

Élément câble Couleur de noyauxPaire Noir Bleu clairTripler Noir Bleu clair Marron

Paires/triples sont numérotés avec du ruban numéroté ou par des numéros imprimés directement sur les conducteurs isolés

L'identification des conducteurs isolés (noyaux) pour les câbles de 0,6 / 1 kV selon la norme NEK

Nombre de conducteur Couleur de noyauxUnipolaire Off-blanc (gris)

Deux noyaux Off-blanc (gris) NoirTrois noyaux Off-blanc (gris) Noir RougeQuatre cœurs Off-blanc (gris) Noir Rouge Bleu

Dessus de 4 cœurs chiffres noirs sur base blancheconducteur de terre Jaune/vert

L'identification des conducteurs isolés (noyaux) pour les câbles de 0,6 / 1 kV selon la norme HD 308 S2

Câbles avec une âme vert / jauneNombre de conducteur Couleur de noyaux*

Trois noyaux Vert/jaune Bleu MarronQuatre cœurs** Vert/jaune - Marron Noir GrisQuatre cœurs Vert/jaune Bleu Marron NoirCinq noyaux Vert/jaune Bleu Marron Noir Gris

** Pour certaines applications seulement.* Dans ce tableau, un conducteur concentrique non isolée, comme une gaine métallique, armures ou écran fils, est pas considéré comme un noyau. Un conducteur concentrique est identifié par sa position et, par conséquent, ne doivent pas être identifiés par la couleur.

Câbles sans noyau vert / jauneNombre de conducteur Couleur de noyaux*

Deux noyaux Bleu MarronTrois noyaux** - Marron Noir GrisTrois noyaux Bleu Marron NoirQuatre cœurs Bleu Marron Noir GrisCinq noyaux Bleu Marron Noir Gris Noir

** Pour certaines applications seulement.* Dans ce tableau, un conducteur concentrique non isolée, comme une gaine métallique, armures ou écran fils, est pas considéré comme un noyau. Un conducteur concentrique est identifié par sa position et, par conséquent, ne doivent pas être identifiés par la couleur.

L'identification des conducteurs isolés (noyaux) pour le 3,6 / 6 kV, 6 / 10kV, 8,7 / 15 kV, 12 / 20kV et 18 câbles / de 30 kV

Nombre de conducteur Couleur de noyauxUnipolaire blanc cassé isolation + noir semi couches conductrices

Trois noyauxOff-blanc isolation + noir semi couches conductrices identifiées par des fils blanc-noir-rouge

sous et plus l'écran métallique sur chaque noyau individuel.conducteur de terre Jaune/vert

Copyright@ Caledonian Câbles Offshore & Marine

Page 126: Caledonian Câbles Offshore & Marine NORME NEK606

Pouvoir et de contrôle Câbles

124 ADDISON www.caledonian-cables.fr

NEK606 Caledonian Câbles Offshore & Marine

www.caledonian-cables.co.uk

Caledonian Câbles Offshore & Marine

NORME NEK606

www.caledonian-cables.co.ukwww.caledonian-cables.fr

Caledonian

ROYAUME-UNI

Marchants Centre industriel,Mill Lane, Laughton, Lewes,East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]

HONG KONG

Unité B 22 / F CMA bâtiment,64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]

Copyright@ Caledonian Câbles Offshore & Marine