calling system itcs · dimenzije itcs system is designed for using on board ships for calling from...
TRANSCRIPT
DIMENZIJE
ITCS system is designed for using on board ships for calling from hospital and refrigerating room.
System is realised using control units ITCS-1 (single) or ITCS-2 (double) and arbitrarily numbers or peripheral
units ITCS-C1, ITCS-C2 or ITCS-C3. Can be fully equipped with signalling unit type ITCS-S and repeater for call
acceptance type ITCS-R.
CALLING SYSTEM ITCS
designed for
CALL FROM HOSPITAL
CALL FROM REFRIGERATING ROOM
ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS
02 · NAVIGATION
4 cores
2 cores
3 cores
4 cores
4 cores
2 cores
3 cores
ITCS-1
ITCS-R
ITCS-S
ITCS-C3
ITCS-R
ITCS-S
ITCS-C1
ITCS-C2
ITCS-2
output
Power failure alarm
output
External alarm
Power supply
230V,AC or 24V,DC
output
Power failure alarm
output
External alarm
Power supply
230V,AC or 24V,DC
RE
FR
IG
ER
AT
IN
G R
OO
M
HO
SP
IT
AL
R
OO
M
can be
ITCS-1
Control unit for indication and acceptance
of call
Call is indicated by zummer and LE-diode
Flush mounting
Bulkhead mounting on request only
Power "ON" is indicated by green LE-diode
Acceptance of call is done by push button
"Accept"
Relays for external and power failure alarm
Power supply: 230V,AC or 24V,DC
Consumption: 3W
ITCS-2
Control unit for call from hospital
and refregerating room in one box,
electrically separated
All functions as in the ITCS-1,
but doubled
Flush mounting
Bulkhead mounting on request only
Power supply: 230V,AC or 24V,DC
Consumption: 6W
DIMENZIJE
72
14
4
13
8
68
CONSOLE
CUT-OUT
144
14
4
138
13
8
CONSOLE
CUT-OUT
Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
As additional unit for call acceptance used
with ITCS-1 or ITCS-2 only
Call is indicated by red LE-diode and zummer
Call acceptance is done by push button
"Accept"
Green LE-diode indicate "Power on"
Bulkhead mounting
Flush mounting on request only
Consumption: 1W
ITCS-R
Unit for calling with additional push
button on cable
Mostly used near the hospital's bed
Red LE-diode lights until the call is accepted
Bulkhead mounting
Flush mounting on request only
Consumption: 0,5W
ITCS-C1
General purpose unit for calling with
same functions as ITCS-C1, but without
push button on cable
Consumption: 0,5W
ITCS-C2
Water resistant illuminated push
button for calling
Bulkhead mounting
IP-56
Consumption: 2W
ITCS-C3
Signalling unit with zummer and
red LE-diode indication
Activated by 24V,DC
Bulkhead mounting
Flush mounting on request only
Consumption: 1W
ITCS-S
58
58
58
58
80
70 1275
Ø4.5 fixing
holes
5 5
15
68
15
28
38
PG13.5
80
48
Ø5 fixing
holes
12
5
11
3
PG13.5
80
48
Ø5 fixing
holes
12
5
11
3
PG13.5
80
48
Ø5 fixing
holes
12
5
11
3
PG13.5
80
48
Ø5 fixing
holes
12
5
11
3
PG13.5
NAVIGATION AND SIGNAL LIGHTS PANELS
Panels are used to control operation of navigation lights on board ships. Audible and visual alarm is
activated if there is a fault in circuit or lamps. New generation of microcontroller technology is used.
NLP 220, double panel is used for controling main and spares lanterns (2x12 lanterns can be controled).
The equipment is designed and produced in accordance with requirements of major classification societies.
Fault in lantern or lantern's circuit is followed by audio alarm and blinking of corresponding LED. Audio
alarm can be acknowledged, but blinking of LED will remain until the lantern circuit is repaired or switched-
off. Internal NiCd battery is used for power failure alarm activation. All panels are supplied with dimmer
and test facility. Bulit-in potential-free change-over contact can be used to activate external alarm signalling
device.
SLP 220
SIGNAL
LIGHTS
PANEL
NLP 24-7
NLP 220-7
NAVIGATION
LIGHTS PANEL
220V,AC*
o o
0 C/+55 C
up to 12
NLP 220
24V,DC
o o
0 C/+55 C
up to 12
NLP 24
220V,AC
o o
0 C/+55 C
up to 7
NLP 220-7
24V,DC
o o
0 C/+55 C
up to 7
NLP 24-7
220V,AC
o o
0 C/+55 C
up to 23
SLP 220
*110V,AC available upon request.
Number of lanterns
o
Ambient temperature min/max C
Power supply
TECHNICAL CHARACTERISTICS
NLP 220
double
220V,AC
o o
0 C/+55 C
2x12
ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS
NLP 24
NLP 220
NAVIGATION
LIGHTS PANEL
NLP 220,
double
NAVIGATION
LIGHTS PANEL
02 · NAVIGATION
FLUSH MOUNTING
BULKHEAD MOUNTING
A
B
C
D
DIMENSIONS (mm)
200
500
160
460
NLP 220 / NLP 24
300
500
260
460
SLP 220
A
B
C
D
E
F
Depth
DIMENSIONS (mm)
170
416
160
387
10
7
125
180
275
170
246
10,5
9
110
NLP 220 / NLP 24 NLP 220-7 / NLP 24-7
235
416
224
390
9
7
125
SLP 220
A
C 120
380 mm
for service
cable entry
fixing
holes
125
B
D
A
B
1
0
2
NAVIGATION LIGHTS PANEL
C
E E
FD
F
E E
M4 M4
M4M4
CUT-OUT
INELTEH
All dimensions are in mm.
NLP 220, double
Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
235
416
224
390
9
7
125
ITDAC-14DB WATCH MONITORING UNIT WITH ALARM TRANSFER
Comprise two parts: Watch monitoring unit without alarm transfer (described above) and alarms transfer
for the navigation equipment, specified by rules of classification societies. Alarm caused by any navigation
system component connected to unit, has to be acknowledged on the equipment which activated the alarm
within 30 seconds. If not, alarm will be transferred to officers accomodation and signalized on the signalling
unit(s) of type SU. Every time when alarm from navigation equipment connected to unit is acknowledged,
watch monitoring period is also reseted.
Watch monitoring unit
without alarm transfer
type ITDAC-14DB
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
SU - SIGNALING UNIT
RESET
RU - RESET UNIT
INELTEH
WATCH MONITORING SYSTEM
WITH OR WITHOUT ALARM TRANSFER
System, also called "Dead Man"
alarm for the bridge ensure the
continuous monitoring of the
bridge operator fitness as
required during "one man
bridge" operation.
Equipment meets requirements
of all major classification
societies and IMO regulations.
RECTIFIER
220V,AC / 24V,DC with automatic changeover
220V,AC 24V,DC
24V,DC
EXTERNAL RESET
UNITS
(flush mounting)
1. Back-up navigator
2. Back-up navigator
3. Back-up navigator
Officers' day room
Officers' mess
Officers' office
Captain's office
Captain's cabin
WATCH MONITORING AND ALARM TRANSFER SYSTEM BLOCK DIAGRAM
RESET
RU - RESET UNIT
INELTEH
RESET
RU - RESET UNIT
INELTEH
ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS
02 · NAVIGATION
INELTEH
Watch monitoring unit
with alarm transfer
type ITDAC-14DB
ITDAC-14DB WATCH MONITORING UNIT WITHOUT ALARM TRANSFER
Before using ON-OFF key switch, time selection should be done (6, 9 or 12 min). Time selection is possible
in OFF position of key-switch only. When the selected time expires, pre-warning alarm occurs (on the
bridge) and can be acknowledged within 30 seconds using RESET button on the equipment or external
reset units type RU. If not acknowledged, alarm will be activated in officers' quarters through signalling units
type SU. Power failure alarm, dimmer and external alarm signalization are provided.
RU (Reset Unit) DIMENSIONS
WATCH MONITORING UNIT WITH OR WITHOUT ALARM TRANSFER DIMENSIONS
SU (Signaling Unit) DIMENSIONS
All dimensions are in mm.
SU - SIGNALING UNIT
80
DEPTH IS 56mm
12
5
49
Fixing holes
4x5mm
Position of cable
glands in case of
two glands
PG13.5
11
4
15.515.5
5.5
20
5.5
20
920
98
13
6
Term
inal block
92
09
8
136
Terminal blocks
138
13
8
144
14
4
Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
46
7
2
7
2
50
4 x M4
RESET
RU - RESET UNIT
60
467
60
46
7
FIXING HOLES Ø4.5
CONSOLE
CUT-OUT
INELTEH
INELTEH
CONSOLE
CUT-OUT
DEPTH IS 70mm.