care essentials disposable respirators

6
Head office: 25 Slevin Street, North Geelong Victoria 3215, Australia Factory: 103 Mornington Street, North Geelong Victoria 3215, Australia Care Essentials Pty Ltd ABN: 89 148 060 486 Telephone: +61 3 52771455 Fax: +61 3 52771411 www.careessentials.com.au Specifications: Particulate Filtration Efficiency >95% P2 Respirator - certified as per AS/NZS 1716:2012 by Certmark. Certificate Number: CMI-TT10059 Made in Australia ARTG 340518 Available in 2 sizes: Regular and Small MSK-001 MSK-002 Care Essentials Disposable Respirators MSK-001S MSK-002S The Intended Use of the Respirators: Reduces wearer’s exposure to particles including small particle aerosols and large droplets (only non-oil aerosols). Respirator is non-powered air purifying particulate respirator Order Codes for Regular Size: MSK-001 Disposable Respirator with Earloops- Regular size MSK-002 Disposable Respirator with Headband- Regular Size Order Codes for Small Size : MSK-001S Disposable Respirator with Earloops – small size MSK-002S Disposable Respirator with Headbands – small size * All Respirator models have been performance tested to N95 NIOSH standard (42 CFR 82 subpart K) by Intertek USA, but not NIOSH registered NOTE: Above images only show the design and shape. Images do not show the actual markings and labellings. Actual product may have additional/different markings to comply with the relevant local regulatory requirements.

Upload: others

Post on 26-Jan-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Care Essentials Disposable Respirators

Head office: 25 Slevin Street, North Geelong

Victoria 3215, Australia

Factory: 103 Mornington Street, North Geelong

Victoria 3215, Australia

Care Essentials Pty Ltd ABN: 89 148 060 486

Telephone: +61 3 52771455 Fax: +61 3 52771411

www.careessentials.com.au

Specifications:

• Particulate Filtration Efficiency >95%

• P2 Respirator - certified as per AS/NZS1716:2012 by Certmark.

• Certificate Number: CMI-TT10059

• Made in Australia

• ARTG 340518

• Available in 2 sizes: Regular and Small

MSK-001

MSK-002

Care Essentials Disposable Respirators

MSK-001S

MSK-002S

The Intended Use of the Respirators:

Reduces wearer’s exposure to particles including small particle aerosols and large droplets (only non-oil aerosols). Respirator is non-powered air purifying particulate respirator

Order Codes for Regular Size:

MSK-001 Disposable Respirator with Earloops- Regular size

MSK-002 Disposable Respirator with Headband- Regular Size

Order Codes for Small Size :

MSK-001S Disposable Respirator with Earloops – small size

MSK-002S Disposable Respirator with Headbands – small size

* All Respirator models have been performance tested to N95 NIOSH standard (42 CFR 82 subpart K) by Intertek USA, but not NIOSH registered

NOTE:Above images only show the design and shape. Images do not show the actual markings and labellings. Actual product may have additional/different markings to comply with the relevant local regulatory requirements.

Page 2: Care Essentials Disposable Respirators

1. Wash your hands 2. Hold the mask by each ear loop 3. Place a loop around each ear 4. Press the nose clip 5. Check for a tight �t

N95

N95

Safe Mask Handling InstructionsRespirator Mask Fitting - Models MSK-001 and MSK-001S

Respirator Mask Removal- Models MSK-001 and MSK-001S

1. Wash your hands 2. Hold the mask by each ear loop 3. Place a loop around each ear 4. Press the nose clip 5. Check for a tight �t

N95

N95

1. Wash your hands 3. Pull forward to remove mask 2. Hold the mask by each ear loop 4. Press the nose clip 5. Check for a tight �t

N95

N95

1. Wash your hands 3. Pull forward to remove mask 2. Hold the mask by each ear loop 4. Press the nose clip 5. Check for a tight �t

N95

N95

1. Wash your hands 3. Pull forward to remove mask 2. Hold the mask by each ear loop 4. Press the nose clip 5. Check for a tight �t

N95

N95

1. Wash your hands 3. Pull forward to remove mask 2. Hold the mask by each ear loop 4. Press the nose clip 5. Check for a tight �t

N95

N95

4. Discard the used mask 5. Wash your hands

Page 3: Care Essentials Disposable Respirators

Safe Mask Handling InstructionsRespirator Mask Fitting - Models MSK-002 and MSK-002S

2. First flatten/straighten the nose wire on the mask as shown in the

image below. This will allow nose wire to be better formed to your nose

during fitting.

3. Next, position the mask asshown in the Figure 3 and wear the top head band as

shown in the Figure 4.

4. Now, place two fingers on the bottom twowelds as shown in the Figure 5 and 6. Next, pull the bottom head band over your head as shown in Figure 7 and finally resting thebottom head band over the neck as shown

in Figure 8.

5. If there are any folds around the mask,straighten them using your fingers. If there

is any hair stuck under the mask move them out of the mask as well.

6. Make sure to position the nose wire of the mask at the top part of your nose. Do not position the nose wire around the pointy part of your nose as this would lead to

potential failure of the fit. Use both hands and form the nose wire to fit it to your nose as shown in the image below. Press hard on the sides of your nose for the nose wire

to give a better fit. Take care not to create a pointy V shape in the middle of the mask as shown in the figure 11 above. Next, check for a tight fit.

Figure 1

1. Wash Hands.

Figure 2

Figure 4Figure 3

Figure 8Figure 7Figure 6Figure 5

Figure 9

Figure 10 Figure 11

Page 4: Care Essentials Disposable Respirators

Respirator Mask Removal:

Models MSK-002 and MSK-002S

Pull the head bands overyour head and to the front.

Remove the mask.

3

4

Discard the usedmask.

Wash your hands.

1

2

Wash your hands.

Page 5: Care Essentials Disposable Respirators

Respirators with Ear loops- MSK-001 and MSK-001S

Respirators with Headband- MSK-002 and MSK-002S

Guideline: How to prepare for the CareEssentials Respirator Fit Test

(To be performed on a quantitative fit testmachine)

2. Next, for Respirators with the headband (MSK-002 andMSK-002S), pull the bottom head band over your head. Then,position the bottom head band around your neck(the testingtube is connected to the mask that is hindering the normal

procedure done to wear the mask).For respirators with ear loops (MSK-001 and MSK-001S),

wear the ear loops over each ear as you would normally wearthe respirator mask.

3. Lastly, position the first head band over your head andplace around the crown.

For Respirators with ear loops (MSK-001 andMSK-001S), this step is not applicable.

1. First flatten/straighten the nose wire onthe mask as shown in the image. This willallow the nose wire to be better formed to

your nose during the fitting.

Please note: The wearer should be clean, shaven and have eyewear removed prior to this test.

Page 1 of 2

Page 6: Care Essentials Disposable Respirators

4. If there are any folds around the mask, straightenthem using your fingers. If there is any hair stuck under

the mask move them out of the mask as well.

This step is applicable to all Care Essentialsrespirator models.

6. Carry out a real time test (using aquantitative fit test machine) to find out if thereare any leaks around the nose wire area. If there are any leaks, reform the nose wireto your nose. It is better to straighten the nose wire again and form it to your noseusing both hands. If it’s hard to get a better fit, try a new mask on, following theabove guidelines. This is because the mask loses the ability to fit better if its nose

wire area is bent and relaxed too many times to get a better fit.

5. Make sure to position the nose wire of the mask at the top partof your nose (i.e. bridge of the nose). Do not position the nose

wire around the pointy part of your nose (i.e. do not place over thenostrils) as this would lead to potential failure of the test. Use

both hands and form the nose wire to fit it to your nose as shownin the image. Press hard on the sides of your nose for the nose

wire to give a better fit. Take care not to create a pointy V shapein the middle of the mask as shown in the second image.

This step is applicable to all Care Essentials respirator models.

Head office: 25 Slevin Street, North Geelong,Victoria 3215, Australia

Factory: 103 Mornington Street, NorthGeelong, Victoria 3215, Australia

Care Essentials Pty LtdABN: 89 148 060 486

Telephone: +61 3 52771455Fax: +61 3 52771411

Page 2 of 2