case history - wedge tower - cooling tower corrosion ...€¦ · case study wedge tower - 2016...

1
CASE STUDY WEDGE TOWER - 2016 Cooling Tower Protection Project Data • Long Term Protection • Easy & Fast Application • No Special Training Required • UV Resistance • Conforms to Irregular Shapes • Tape has an 85 year proven history of application Date Published: 09/28/2016 Benefits Recently Hines, a large real estate developer, acquired the rights to the Wedge Tower in downtown Houston, TX. After inspection it was concluded the cooling tower would have to be rebuilt and the piping replaced due to corrosion. Due to past successes they have experienced with Denso on numerous cooling towers over the years, the decision was made to again use the Denso Petrolatum Tape System to provide long term corrosion protection on all of the piping, valves, anges, etc. After a short on-site training session with a Denso representative, the contractor MFR Fluid & Air was able to install the Denso Petrolatum Tape system quickly and easily much to their satisfaction. The scope of work consisted of minimal surface preparation (SSPC SP-2/SSPC SP-3), followed by the application of a thin layer of Denso Paste S105, Densyl Tape with a 55% overlap, and a protective layer of HDPE Outerwrap with SmartBand Strapping. For irregular areas such as anges and valves, the Denso Proling Mastic was also applied to provide a smooth prole to tape over and then top coated with the Denso Weathershield 15 in place of the HDPE Outerwrap. Another successful application gave the developer and contractor condence the life of their cooling tower piping will be extended while preventing corrosion for many years to come. Project Details Location Houston, TX Completion September 2016 Project Type Cooling Tower Protection Products Used Denso Paste S105 / Densyl Tape / HDPE Outerwrap with Smartband Strapping / Proling Mastic / Denso Weathershield 15 Contractor or Applied By MFR Fluid & Air Weathershield 15 brushed applied onto Densyl Tape protecting a valve anged as a top coat. Overview of the complete Denso corrosion protection system for cooling towers for pipes, valves and ttings. Piping protected with an HDPE Outerwrap and Smartband Strapping system. Denso North America - USA 9710 Telge Road / Houston, TX 77095 Tel: 281-821-3355 Fax: 281-821-0304 [email protected] Denso North America - Canada (Ontario) 90 Ironside Crescent, Unit 12 / Toronto, M1X 1M3 Tel: 416-291-3435 Fax: 416-291-0898 [email protected] A Member of Winn & Coales International www.densona.com

Upload: others

Post on 22-Jun-2020

39 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Case History - Wedge Tower - Cooling Tower Corrosion ...€¦ · CASE STUDY WEDGE TOWER - 2016 Cooling Tower Protection Project Data • Long Term Protection ... the contractor MFR

CASE STUDYWEDGE TOWER - 2016 Cooling Tower Protection

Project Data

• Long Term Protection

• Easy & Fast Application

• No Special Training Required

• UV Resistance

• Conforms to Irregular Shapes

• Tape has an 85 year proven history of application

Date Published: 09/28/2016

Benefits

Recently Hines, a large real estate developer, acquired the rights to the Wedge Tower in downtown Houston, TX. After inspection it was concluded the cooling tower would have to be rebuilt and the piping replaced due to corrosion. Due to past successes they have experienced with Denso on numerous cooling towers over the years, the decision was made to again use the Denso Petrolatum Tape System to provide long term corrosion protection on all of the piping, valves, fl anges, etc. After a short on-site training session with a Denso representative, the contractor MFR Fluid & Air was able to install the Denso Petrolatum Tape system quickly and easily much to their satisfaction. The scope of work consisted of minimal surface preparation (SSPC SP-2/SSPC SP-3), followed by the application of a thin layer of Denso Paste S105, Densyl Tape with a 55% overlap, and a protective layer of HDPE Outerwrap with SmartBand Strapping. For irregular areas such as fl anges and valves, the Denso Profi ling Mastic was also applied to provide a smooth profi le to tape over and then top coated with the Denso Weathershield 15 in place of the HDPE Outerwrap. Another successful application gave the developer and contractor confi dence the life of their cooling tower piping will be extended while preventing corrosion for many years to come.

Project Details

Location Houston, TX

Completion September 2016

Project Type Cooling Tower Protection

Products Used Denso Paste S105 / Densyl Tape / HDPE Outerwrap with Smartband Strapping / Profi ling Mastic / Denso Weathershield 15

Contractor or Applied By MFR Fluid & Air

Weathershield 15 brushed applied onto Densyl Tape protecting a valve fl anged as a top coat.

Overview of the complete Denso corrosion protection system for cooling towers for pipes, valves and fi ttings.

Piping protected with an HDPE Outerwrap and Smartband Strapping system.

Denso North America - USA9710 Telge Road / Houston, TX 77095Tel: 281-821-3355 Fax: [email protected]

Denso North America - Canada (Ontario)90 Ironside Crescent, Unit 12 / Toronto, M1X 1M3Tel: 416-291-3435 Fax: [email protected] A Member of Winn & Coales International