case study for colegrave primary school, newham, london

2

Click here to load reader

Upload: airtherm-engineering

Post on 20-May-2015

34 views

Category:

Business


0 download

DESCRIPTION

Airtherm Engineering's track record of successful and efficient projects was demonstrated by the recent installation of our 'Canv-ient' Island kitchen canopy system at Colegrave Primary School in Newham, London. The project involved the successful liaising between Fowler Martin, AC Preou Limited and Newham Council (consultant, contractor and client, respectively). Airtherm Engineering Limited liaised with both the consultant and the contractor at all time, attending site meetings, providing comprehensive technical submission, including calculations and drawings for approval prior to manufacture of the equipment.  We supply a wide range of kitchen canopy systems to meet the demands of the most modern commercial kitchens and are used for the commercial, healthcare, educational and private sectors and are increasingly popular in restaurants, schools, hospitals and hotels. Our own Canvent canopy systems can be configured to suit virtually any application, with a range of advanced features such as heat recovery, uv filtration, fire suppression and gas safety detectors fitted as necessary. Our range includes condense, dishwash, wall mounted, extract and supply, peripheral extract and induction canopies. All canopies are manufactured from 304 (En 1.4301) or 316 (En 1.4401) where specified and are suitably braced to prevent product distortion. All joints are welded and polished. Systems are manufactured to the strict guidelines of DW/172, British Standards and conform to HSE for kitchen ventilation systems. Our control systems include gas detection and shut off, CO and CO2 sensors and fire suppression. Our canopy lighting products are sealed and meet all modern hygiene and safety standards.

TRANSCRIPT

Page 1: Case study for colegrave primary school, newham, london

Consultant

■ Fowler Martin

Client

■ AC Preou Ltd

Sector

■ Education

Products

■ Can-iVent System

Equipment

■ Cooking Equipment

Application

■ Input & Extract System

0844 809 2509 | airtherm.co.uk | [email protected]

Project Profile

Colegrave School – Newham, London

Completed Installation

Can-iVent Island Kitchen Canopy

Airtherm Engineering's track record of successful and efficient projects was demonstrated by the recent installation of our 'Canv-ient' Island kitchen canopy system at Colegrave Primary School in Newham, London. The project involved the successful liaising between Fowler Martin, AC Preou Limited and Newham Council (consultant, contractor and client, respectively). Airtherm Engineering Limited liaised with both the consultant and the contractor at all time, attending site meetings, providing comprehensive technical submission, including calculations and drawings for approval prior to manufacture of the equipment.

Ansul R-102

Working Progress

Page 2: Case study for colegrave primary school, newham, london

Product Range Our product range extends from simple condense canopies, extract only, island or wall mounted canopies, through to our air injection island systems allowing both input and extract. If required, the input air can be pre-heated for additional internal staff comfort during the cold winter months. All products can be configured to suit each individual application.

Manufacture All canopies are manufactured from 304 (En 1.4301) or 316 (En 1.4401) stainless steel where specified and are suitably braced to prevent product distortion. All joints are welded and polished.

Our Canopies are cut, punched and folded into sub sections and factory assembled by means of computer controlled seam welds, and non-visible mechanical fixings. Systems are manufactured to the strict guidelines of DW/172, British Standards and conform to HSE for commercial kitchen ventilation. Wall mounted or island canopies can be manufactured to meet almost any dimension but typically 1000mm to 8000mm long. The system ductwork is manufactured and installed to incorporate cleaning and maintenance access doors to fully comply with DW/144 & TR/19 standards.

Canopy Lighting The units are designed and manufactured to deal with a wide ranging and varied commercial application, and can deal with humidity, condense rich, as well as hot and greasy environments. These units are normally recessed into the canopy ceiling providing easy cleaning and maintenance of the unit exterior. This also helps to greatly reduce the build-up of grease and other contaminates usually associated with the commercial kitchen environment. Recessed Incandescent Units: • Approved for use in commercial kitchen applications • Meet with guidelines for DW172 & HSE Guidelines • Satin finished stainless steel matching faceplates for matching hood interiors • Tempered prismatic glass diffusers Fire Suppression System The island kitchen canopy was fitted with a R102 Ansal fire suppression system which conforms to NFPA standards 17, 17a and 96 and is UL300 listed by Underwriters Laboratories Inc . The system was supplied with nozzles, detectors, cartridges, liquid agent, fusible links, pulley tress and elbows as required for the specific commercial kitchen application at Colegrave Primary School., Newham, London

0844 809 2509 | airtherm.co.uk | [email protected]

Product Solution

Island Kitchen Canopy

External Supply Air Ductwork

Ansul R-102 Diagram

Contact Details:

Airtherm Engineering Ltd

Unit 8A,

Gainsborough Trading Est

Stourbridge

West Midlands

DY9 7ND

Tel: 0844 8092509

Fax: 01384 375218