case study - health level seven international...hl7 aid wgm, sun oct 4, 2015, atlanta, ga, usa 3©...
TRANSCRIPT
1HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Case study:
“HL7 ORM v2.3 into FHIR REST-API”
Jörg-Uwe Meyer,
MT2IT GmbH & Co. KG, Germany
www.mt2it.com
2HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Company Info: MT2IT – your safe medical network®
OR
Hospital
Communication
Server
Interoperability
Gateway• MT2IT enterprise founded in Nov.
2011 by Dr. J.-Uwe Meyer
• MT2IT provides cloud-based
software services for HDOs and
medical device companies
• MT2IT interconnects medical devices
and medical information systems
• Work in progress: Smart app for
managing chronic wounds
• Work in progress: Smart app for
surgical documentation and machine
supported logging of procedures and
events in the OR
3HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Exchange of Patient-Specific Resources
Clinical IT-Network
Point-of-Care Network
w/ HL7 HCD/ IEEE 11073 medical devices
ITAS UKSH-IT
VM Windows Azure Web Server
(IIS8, ASP.NET, OWIN, Service
Bus)
VM Windows
Web Server
(IIS8, ASP.NET)
(Information Technology
Application Server)
SESAPMT2IT Interoperability
Gateway/Engine
Public Cloud
(Secure Service
Application Proxy )
VM Servers ITAS & SESAP
4HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
«ITAS (IT Application Server)»/ Mediation Server
HL7-FHIR Spark Engine Library
«SESAPAzure DSTU-2
Client»
HL7-FHIR Spark Mongo Library
Web-Application
FHIR-Controller
FHIR
MongoDB
Mediation
Server
Accomplished by Sept. 29, 2015: Spark Engine Library, Spark Mongo Library und Mongo DB Driver are installed
UKSH-ITAS http://193.175.223.99:1397/
5HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
http://193.175.223.99:1397/
Implementation of FHIR DSTU2 Server on ITAS
6HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Order-Query
Case Study:
Mapping HL7 ORM in FHIR Resources and Services
User Registration
UKSH-
Kommunikations-
server
OR
Safety
Manager
User Client
Clinical
Information System
IS
Application
Software
IT-App Server
«ITAS FHIR
Server»
«UKSHKomm.Server»
«SESAP App/Int.Engine»
«UKSHKIS»
7HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
AGFA ORBIS ORM User Template
7
8HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
HL7 General Order Message (ORM) v2.3
8
9HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
HL7 ORM into FHIR Services: Systems Deployment
9
10HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
HL7 v2.3 ORM-Message File (German)
MSH|^~\&|ORBIS-LSTM|LSTM|MEDNOVOL|Neurochirurgie|
20150713130815||ORM^O01|MSGLSTM15014375|P|2.3
PID|||1804260|7035875|Barez^HOLGER^^""|""|19501105|M|||Maria-
Goeppert-StraÃYe 7 71^^Lübeck^^23538^D ||||||||
PV1||I|LZ390SC^^^LNEUR^^^^^26528001||||WILL-
A^Gutow^Michel^^Dr.|||N|||||||||7035875
|||||||||||||||||||||||||20150216153700||||||LSTM-2015-036624
ORC|NW|1529430062|LSTM-2015-036624^^
1.2.40.0.13.0.11.9346.5.2015036624.181958.20150713130807||||||
20150713130816|WILL-A^Gutow^Michel^^Dr.||WILL-
A^Gutow^Michel^^Dr.||||||^OT||
OBR||1529430062|LSTM-2015-036624^^
1.2.40.0.13.0.11.9346.5.2015036624.181958.20150713130807
|LNCHIOP025^Exzision Hypophysentumor^Exzision
Hypophysentumor^L OP^OT|||||||||Fragestellung: Entfernung des
Tumors erbeten|||WILL-A^Gutow^Michel^^Dr.||||||20150713130816
||OT|S|||||||||||20150713133000||||||||
11HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Parsing HL7 ORM Message Attributes 1/2
In the following table provides a list of attributes in the ORM^O01 General Entry
Order message that have to be parsed from the segments MSH, EVN, PID, PV1,
ORC and OBR of the example file “Barez7035875.hl7”:
12HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Parsing HL7 ORM Message Attributes 2/2
In the following table provides a list of attributes in the ORM^O01 General Entry
Order message that have to be parsed from the segments MSH, EVN, PID, PV1,
ORC and OBR of the example file “Barez7035875.hl7”:
13HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Mapping HL7 ORM Segments into FHIR Resources/Objects
14HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Mapping HL7 ORM Segments into FHIR Resources/Data Type
15HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Mapping HL7 ORM Segments into FHIR Resources/Data Type
16HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Mapping HL7 ORM Segments into FHIR Resources/Data Type
17HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Mapping HL7 ORM Segments into FHIR Resources/Data Type
18HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Referencing the Identified HL7 ORM FHIR Resources …?
Order
Procedure Request
Message Header
Encounter
Patient(undergoing
surgery)
Location(OR)
Practitioner(Surgeon)
Organization
Organization
Application: Surgical Procedure Session
19HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Point-of-Care Network
Clinical IT Network
Open WebInterface(OWIN)
1
2
3
HL7-FHIR = Fast HealthcareInteroperability Resources:Standard for Mobile Communication in Healthcare
4
5
67
«FHIR Server»
Doctors,Nurses,…
Patient
«Interoperability Gateway»Service App Engine
View Engine
Sensors
20HL7 AID WGM, Sun Oct 4, 2015, Atlanta, GA, USA © Jörg-Uwe Meyer, Ph.D., MT2IT
– your safe medical network®
Thank you!
“HL7 ORM v2.3 into FHIR REST-API”
Jörg-Uwe Meyer,
MT2IT GmbH & Co. KG, Germany
www.mt2it.com