Page 1: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 2: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 3: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 4: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 5: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 6: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and
Page 7: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

T

EF 01

EF 02

EXHAUST DUCT, UP THRU ROOF

6"Ø

TO ROOF CAP

VENTLESS FRYERHOOD SYSTEM

1

12x8

S-2 600

S-2 600

S-1 50

S-2 550

S-2 400

24x14

24x14

6"Ø

24x14

S-2 400

S-2 300

S-2 200

S-2 500

24x14

RR-1 1820

RR-1 1820

S-2 500

24x14

3

5DUCT SMOKEDETECTOR (TYP.)

VENTLESS DISHMACHINEHOOD SYSTEM

6

2

8

7

RTU 01

RTU 02

5

44

M1.0SCHEDULE

1

DESCRIPTION

CEILING DIFFUSER/SUPPLY REGISTER

EXHAUST AIR DUCT (RISE/DROP)

RETURN AIR DUCT (RISE/DROP)

SINGLE LINE DUCT BRANCH TAKE-OFF

DOOR UNDERCUT (3/4" MINIMUM)

FLEXIBLE DUCT (5'-0 MAXIMUM)

DUCT TRANSITION (RECTANGULAR TO ROUND)

DUCT LINING (1" THICK UNLESS OTHERWISE NOTED)

RECTANGULAR DUCT ELBOW WITH TURNING VANES

(ARROWHEAD REPRESENTS NUMBER OF THROW)

FURNISHED AND INSTALLED BY MECHANICAL

INSTALLED BY ELECTRICAL CONTRACTOR.FURNISHED BY MECHANICAL CONTRACTOR AND

FURNISHED AND INSTALLED BY ELECTRICAL

RR/RG RETURN REGISTER/GRILLE

CONTRACTOR.

DIAMETER

CONTRACTOR.

DOOR LOUVER

CONDENSATE DRAIN

DIA.

UC

DL

T-STAT

D

FLEX

EXHAUST REGISTER/GRILLE

FIRE DAMPER

MANUAL VOLUME DAMPER

FLEXIBLE CONNECTION

MVD

(L)

FD

FC

ER/EG

SUPPLY AIR (RISE/DROP)

CD/SR

RA/RET

EA/EXH

SA/SUP

SYMBOL & ABBREV.

T-STAT

PROGRAMMABLE THERMOSTAT

AFUE

TOTAL NET

STA

RTE

R

BY E.C.115/1Ø

ELECT.

MATERIAL

ALU

M.

PLA

STI

C

PRESSUREEASAOA RAITEM

875

--

-875---- --EF-1

ERTU-1

TOTAL

MANUFACT. MODEL NO. REMARKS

DUTY

SU

RFA

CE

SU

PP

LY

RE

TUR

N

EXH

AU

ST

CFM RANGE

LAY-

IN

MOUNTINGTYPED

IFFU

SE

R

RE

GIS

TER

GR

ILLE

ORNECKSIZE

CEILING GRID

DIFFUSER FACE

SIZE (INCHES)

(NO.) & AIRPATTERN

QU

AN

TITY

MARK

REMARKSAND

MODEL NO.D-D

R

ACCESSORIES

BIR

DS

CR

EE

N

X

V-B

ELT

AVTEC #180VX13D

BD

D

DIS

C

X

HPRPM

1/21325

SPCFM

1.25"875EF-1

MARK

MANUFACTURER

LBS

REMARKS

OP

ER

. WT.

MO

CP

MC

A

PH

AS

E

VOLT

S

FAN

HPCAPACITY

HEATING

MBH

OUTPUT

COMPRESSOR SECTION

MBHCAPACITYCOOLING

MIN

. EE

R

DRIVECFM ESPANDMANUFACTURER

MODEL NO.MARK

RTU-1

INPUT

1

STAGES

(WATTS)

FOR COMPLETE INFORMATION AND PRICING ON THE TRANE HVACPACKAGE CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNTEXECUTIVE AT TRANE NATIONAL ACCOUNTS.TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986-4822FAX: (502) 499-7870EMAIL: [email protected]

SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL INFORMAITON.

THERMOSTAT SENSOR (REMOTE)

XX-XXX

XX-XXXXX-XXX

AIR BALANCE SCHEDULE CFM 6

AIR DEVICE SCHEDULE 5

MECHANICAL SYMBOLS 9

SUPPLY AND EXHAUST FAN SCHEDULE 2

EXISTING HVAC UNIT SCHEDULE 4

T

TS

M

E

ME

DL

UC

Ø

D

BTU

H/W

ATT

S

230 1150 + 230

875950 4400 + 75

GENERAL NOTES:1. THE PIZZA OVEN HOOD IS ACTIVATED USING A TEMPERATURE RELAY, SET TO 90 DEGREES.2. PROVIDE OUTSIDE AIR THROUGH RTU IS SET AT 21%, UNLESS NOTED OTHERWISE.3. RESTROOM FAN IS ACTIVATED WITH LIGHT SWITCH IN RESTROOM, IS INTERMITTENT, ANDWILL HAVE NO EFFECT TO BUILDING RELATIVE PRESSURE.

LEVEL SUPPORT BY THE G.C. FABRICATED PLATFORM ON THE CONCRETE SLAB.CONDENSING UNITS TO COOLER/FREEZER MOUNTED ON FEILD

WATER HEATER DETAIL 8/P3.0.ROOF AND TERMINATE PER MANUFACTURER'S INSTRUCTION. REFER TOROUTE 3"PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE UP THRU

INSULATION FROM HOOD TO DUCT PENETRATION THRU ROOF. EF-1. INSULATE DUCT WITH 1" MINERAL WOOL EXTERNAL WRAP12"x12" WELDED EXHAUST DUCT FROM OVEN HOOD UP THRU ROOF TO

DO NOT ROUTE DUCTWORK OR PIPING OVER ELECTRICAL PANELS.6'-0" x 8'-0" OVEN HOOD. SEE M2.0.

YUM! APPROVED EMAX MODEL 50 THERMOSTAT MOUNTED ON WALL AT 48" A.F.F. NEAR MANAGER'S DESK. COORDINATE LOCATION WITH HEAT

1

2

3

4

5

7

8

6

MECHANICAL PLAN 1/4"=1'-0" 1

KEY NOTES 3

GASKET

TRANSITION TO ROUNDSEE PLANS FOR SIZE

BUTTERFLY DAMPER WITHARM & LOCKING QUADRANT(TYPICAL)

SHORT RADIUS RIGIDMETAL ELBOW WHERE1.5D FLEX ELBOWCANT BE MAINTAINED

1 1/2" DUCT WRAPINSULATION

FLEX DUCT SEESPECIFICATIONS FORMAX. ALLOWABLELENGTH (TYPICAL)

STRAP HANGER

LOW VELOCITYDUCT

NYLON STRAPFASTENER (TYP)

45° ENTRYCLINCHED COLLAR

1.5DMIN

SUPPLY

MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT RUNOUTS TOSUPPLY DIFFUSERS = 5'-0". FLEX DUCT IS NOT ALLOWEDON EXHAUST, RETURN, AND EXPOSED DUCTWORK.

DIFFUSER INSTALLATION DETAIL N.T.S. 7

GENERAL NOTES 8

SPECIFICATIONS.SHUTDOWN FOR RTU-1. REFER TO ELECTRICAL DRAWINGS ANDINSTALL SMOKE DUCT DETECTOR IN SUPPLY DUCTWORK AND UNIT

THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND SUPPORT OFROOFTOP EQUIPMENT WITH BUILDING STRUCTURE AND CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ROOFTOP UNITS TO ALLOW DUCT CONNECTION AND ROUTING AS SHOWN PER PLANS.

ANY FRESH AIR INTAKE SHALL BE SEPARATED FROM BUILDING EXHAUST, FLUES, OR PLUMBING VENTS AS REQUIRED BY LOCAL CODES.INSTALLATION OF APPROVED ROOFTOP UNITS OTHER THAN TRANE MAY REQUIRE MODIFICATIONS TO DUCTWORK LAYOUT. VERIFY ALL REQUIRED CLEARANCES FOR OTHER MANUFACTURERS.

THE CONTRACTOR SHALL VERIFY ALL STRUCTURAL CONDITIONS FORCEILING SPACE AND EXACT DUCT ROUTE PRIOR TO FABRICATION. VERIFY IN FIELD EXACT ROUTING OF DUCTWORK TO ALLOW PROPER LOCATION OF LIGHTS AS SHOWN.

1.

2.

3.

5.

4.

6.

THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS SHEETS FOR FURTHER INFORMATION.

--

--

XEGER ADVANTAGE

SQ. TO RD. TRANS.XX& 5(4W) 300-500X12x12 24x24 PRODUCTS

PLASTIC DIFFUSERSS-2 (1)2W, (5) 3W,NA120V14000.25"70EF-2 ACCUSERV #05247-017(100w) X XX

---- --EF-2 - ----- --

X2R-1 18x18 24x24(2)4WC

2000X X X

EGERPRODUCTS

PRODUCING EQUIPMENT. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL LINE VOLTAGE WIRING AND CONDUIT.

9

EGER ADVANTAGESQ. TO RD. TRANS.

XX PRODUCTSPLASTIC DIFFUSERS(1)2WC

75X12x126x61S-1

REMOTE TEMPERATURE / HUMIDITY SENSOR, AS LOCATED ON PLANS.

--NRTU-1 720 3650 + 730--

DUCT SMOKE DETECTOR

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

203

0 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

30

339

678

/ 336-8503

T

ELE

PH

ON

E

678/ 3

36-8

508 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

1, 2TRANE

.80"2300 BELT 11.2 71.95 1 208 31YHC 072RTU-2

INSTALL NEW FLEXIBLE CONNECTION AT UNIT.JOISTS. TRANSITION IN ROOF CURB TO NEW ROOF TOP UNIT ANDROUTE NEW SUPPLY AIR DUCT AND RETURN AIR DUCT UP BETWEEN

1, 2120,00TRANE

.80"2300 BELT 11.2 71.95 96,000 1 208 3 36.5 50 93580%1YHC 072

120,00 96,000 80% 36.5 50 935

NOTES:

1. PROVIDE WITH ENTHALPY CONTROLLED ECONOMIZER WITH BAROMETRIC RELIEF.2. PROVIDE WITH UN-POWERED CONVENIENCE OUTLET AND DISCONNECT.3. PROVIDE WITH RETURN AIR DUCT MOUNTED DUCT SMOKE DETECTOR.

Page 8: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

DUCT THIMBLE FABRICATION ANDINSTALLATION REQUIRED BYINSTALLING CONTRACTOR

DUCT THIMBLE

avtec

1N

1N

1N

1N

1N

1N1N

M2.0DRAWINGS

CHINOOK/TAKU-3 (15) BUSINESS DAY LEAD TIME

CHINOOK/TAKU-4 (18) BUSINESS DAY LEAD TIME

ECO ARCH-3 (15) BUSINESS DAY LEAD TIME

ECO ARCH-4 (18) BUSINESS DAY LEAD TIME

CONVEYOR-5 QUOTED LEAD TIME

UDS-5 QUOTED LEAD TIME

LEAD TIME FROM SIGNEDAPPROVED DRAWINGS

& VALIDATED PO

unified brands

randellavtecgroen

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

EL

OP

ME

NT

2030 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 2

04

AT

LA

NT

A, G

EO

RG

IA

30339

67

8/ 336

-850

3 T

ELE

PH

ON

E

678/ 336-8508 F

AC

SIM

IL

E

OS

WE

LL

+

N

IT

IS

HIN

Page 9: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

P1.0

PLUMBINGSCHEDULE AND

NOTES

ABBREVIATIONS

PRESS-TEMPERATURE RELIEF VALVE

PREMIXED TEMPERATURE WATER

FLOOR CLEANOUT OR CLEANOUT TO GRADE

C.D.

F.C.O.

FW

W.C.O.

S.O.V.

H.B.

C.V.

S.O.C.

P.T.R.V.

B.V.

TWTW

FW

CD

CHECK VALVE

BALL VALVE

SHUT-OFF GATE VALVE

SHUT-OFF GAS COCK

FILTERED WATER

WALL CLEANOUT

CONDENSATE DRAIN

HOSE BIBB

ABBREV

S OR W

CW

H.W.R.

HW

S.D.

SYMBOLS

SD

V.

G G

DESCRIPTION

SOIL OR WASTE

COLD WATER

STORM DRAIN

SANITARY VENT

HOT WATER RETURN

HOT WATER

GAS

COLD WATER BELOW GRADE

FILTERED TEMPERED WATER

FLOOR DRAIN

FLOOR SINK

HUB DRAIN

F.S.

F.D.

H.D.

FTW FTW

C.W.

ABOVE FINISHED FLOOR

EXTERIOR CLEAN OUT

CAST IRON

OVERFLOW DRAIN

EXISTING

GAS LINE

NEW

YARD BOX

ROOF DRAIN

VENT THRU ROOF

ACCESS PANEL

VENT BELOW FLOOR

UP THRU ROOF

A.F.F.

E.C.O.

C.I.

G.L.

OFD

(E)

(N)

A.P.

V.B.F.

U.T.R.

V.T.R.

R.D.

Y.B.

S.O.V. SHUT-OFF IN DROP

YARD HYDRANTY.H.

B.F.P. BACKFLOW PREVENTER ASSEMBLY

GREASE WASTEGWGW

UNION

SS

CONDENSATE DRAIN WITH 120V HEAT TAPECD C.D.

TEMPERING MIXING VALVE

CW

HW

HWR

PLUMBING SCHEDULE A

PLUMBING LEGEND B

SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.

ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED INPLACE.

CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISETHE SEWER SYSTEM AS REQUIRED.

PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODE. PROVIDE DEEPSEAL TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.

ALL CLEANOUTS SHALL BE INSTALLED SO THAT THEY ARE READILY ACCESSIBLE. THE CONTRACTOR SHALLCOORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION.

ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS AND OTHER EQUIPMENT SHOWN IN WALLS ORABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.

ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACEAND 10 FEET FROM ANY OUTSIDE AIR INTAKE.

CONTRACTOR SHALL PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.

INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED.

PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OFEQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODEAND RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECEOF EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THEGAS METER.

ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.

REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORKTO BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TOKITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR.

REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS.

ALL GAS LINES SHALL BE SUPPORTED.

ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.

PROVIDE WATER HAMMER ARRESTORS FOR ALL WATER LINES.

PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THEDIAMETER OF THE INDIRECT DRAIN.

PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION ANDCONDITION OF ALL EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATEDWHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.

CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TOAVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.

CONTRACTOR SHALL FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIESHAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0"A.F.F.

CONTRACTOR SHALL PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TOUNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.

THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITHTHE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.

ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.

IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THESTART OF ANY WORK, AND NOTIFY THE OWNER IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICETHE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT.

1.

2.

3.

4.

5.

6.

7.

8.

TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND & SHALL NOT REQUIRE TIGHTGRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BEMOUNTED NO MORE THAN 44" ABOVE THE FLOOR, THE FORCE REQUIRED TO ACTIVATE CONTROLSSHALL BE NO GREATER THAN 5 POUNDS.

A CLEAR FLOOR SPACE 30" WIDE BY 48" LONG SHALL BE PROVIDED IN FRONT OF THE LAVATORY TOALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE & TOE SPACE UNDERNEATH THE LAVATORY.

HOT WATER & DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACE UNDER LAVATORIES.

FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND & SHALLNOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TOACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS/FT LEVER PUSH-TYPE &ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN, SELFCLOSING VALVES ARE ALLOWED IF THE FAUCETS REMAIN OPEN FOR AT LEAST 10 SECONDS.

FLUSH HANDLES SHALL BE ON THE WIDE SIDE OF STALLS IN DISABLED ACCESSIBLE STALLS.

MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE NOT MORE THAN 40" FROM THE FLOOR.

LOCATE HAND DRYER OPERABLE PARTS NOT MORE THAN 40" FROM THE FLOOR.

LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12" OF THE FRONT EDGE OF THE TOILETSEAT.

ACCESSIBILITY NOTES D

GENERAL NOTES C

FS 1 FLOOR SINK 4" 2" -- -- -- 6 --PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP FLUSH WITH FLOOR TILE.

JOSAM / MODEL: JPFS4-PVC

JONESPEC / MODEL: FD-2370-PV4-DS-F

FD 1 FLOOR DRAIN(3")

3" 2" -- -- -- 2 --PVC FLOOR DRAIN, 5" DIA.IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USEDFOR THE FIRST 10'-0" FROM THE DRAIN

ZURN / MODEL: FD-2210

JOSAM / MODEL: 30003-A

WADE / MODEL: 1103

ECO 1EXTERIORCLEANOUT -- -- -- -- -- -- --

CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.

JOSAM / MODEL: 56000

WADE / MODEL: 6000Z

ZURN / MODEL: Z-1400

WC 1WATERCLOSET 4" 2" 1/2" -- -- 4 2 CRANE "ECONMISER" / MODEL: 3H839

SA 1SHOCKARRESTOR -- -- 1/2" -- -- -- --

STAINLESS STEEL CASING WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN.SIZED PER PDI-WH201

WADE / SHOKSTOP

JOSAM / MODEL: 75000

ZURN / SHOKTROL

MV 1MIXINGVALVE -- -- 1/2" 1/2" -- -- --

THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,CHECK VALVES SIZE PER PIPE CONNECTIONS.

HYDROTEK SERIES HBL

LAWLER SERIES 61

LEONARD SERIES 210

S 33-COMP.SINK INDIRECT -- 1/2" 1/2" -- -- 3

STAINLESS STEEL 3 COMPARTMENT SINK, FAUCET & DRAINFURNISHED BY OWNER, INSTALLED BY CONTRACTOR.

AERO # 3F3-DC-YUM-RH48

--

--

S 1 HAND SINK 1-1/2" 1-1/2" -- -- 1/2" 2 1.5STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS.FAUCET W/KNEE PEDAL VALVE. OWNER FURNISHED AND CONTRACTOR INSTALLED. CONTRACTOR TO PROVIDE STAINLESS STEEL SPLASH GUARDS, AS REQUIRED.

AERO # HSK

ALL STRONG, MODEL #HS-1516KSS

SANILAV, MODEL #CLS-505

HD 1 HUB DRAIN 3" 2" -- -- -- 2 --CAST IRON DEEP SEAL P-TRAP WITH FUNNEL, NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG.

JOSAM / MODEL: 88213

WADE / MODEL: 2453EF

ZURN / MODEL: Z-1019

WCO 1WALLCLEANOUT -- -- -- -- -- -- --

CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS PLUG, WITH STAINLESS STEEL ACCESS COVER.

JOSAM / MODEL: 58510

WADE / MODEL: 8560E

ZURN / MODEL: Z-1446-BP

FCO 1FLOORCLEANOUT -- -- -- -- -- -- --

CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.

JOSAM / MODEL: 56000

WADE / MODEL: 6000Z

ZURN / MODEL: Z-1400

WH 1WATERHEATER -- -- 3/4" 3/4" -- -- --

GAS FIRED WATER HEATER, 84% THERMAL EFF., 199,000 BTUH INPUT, INSTANTANEOUS TYPEHEATER, 9.8 GPM @ 35°F RISE, UBBINK CONCENTRIC FLUE/AIR INTAKE SYSTEM (WALL-TYPE),DIRECT ELECTRONIC IGNITION SYSTEM, REMOTE ELETRONIC CONTROLS AND INTEGRALDIAGNOSTICS. SEE NATIONAL PRICING CONTACT BELOW.

RINNAI / RC98HPi (KA3237FFUD)

--

--

VENTSOIL ORWASTE

FIXTUREITEM

WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,ELONGATED BOWL, ADA COMPLIANT, 1.6 GPF, WITH OPEN FRONT SEAT LESS COVER,OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLLUSHMATE OR EQUAL.PROVIDE TANK COVER LOCKS. FLUSH VALVES SHALL BE RIGHT HAND OR LEFT HAND ASREQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDEREQUIREMENTS

WATERFU

WASTEFU

TEMP'DWATER

HOTWATER

COLDWATER

DESCRIPTION MANUFACTURER / MODEL NUMBER

L 1 LAVATORY 1-1/2" 1-1/2" -- -- 1/2" 1 1.5WHITE VITREOUS CHINA, WALL HUNG, WITH WALL HANGAR SUPPORT, 4" CENTERS,WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHEDBY OWNER-INSTALLED BY G.C. SINGLE LEVER TYPE FAUCET, ADA COMPLIANT.CONTRACTOR TO PROVIDE PROPER WALL MOUNTING SUPPORT.

A.S. COMRADE/ MODEL: 0124.024

CRANE "HARWICH" / MODEL: 1412V

S 2 MOP SINK 3" 2" 1/2" 1/2" -- 3 2.25MOP SINK: 24"L X 24" W X 10" H. FIBERGLASS.OWNER FURNISHED AND CONTRACTOR INSTALLED.FAUCET: T & S #B-0674-BSTP, WITH VACUUM BREAKER, FURNISHED BY OWNER-INSTALLED BY G.C.

E. L. MUSTEE & SONS, MODEL # 63M

--

--

GI 1GREASEINTERCEPTOR 4" 3" -- -- -- -- --

GREASE INTERCEPTOR IS EXIISTING PROVIDED B LANDLORD 1,000 G.P.M. EXTERIOR CONCRETE UNIT TO MEET LOCAL REQUIREMENTS..

SCHIER / TRAPPER II #PATG-3050

--

--

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

WATER HEATER NATIOINAL ACCOUNT PROCESS:RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:

RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:

1) CNA contacts Rinnai Inside Sales at 1.866.383.0707.

2) Rinnai will provide CNA with distributor contact in the project market to facilitate ordering.

3) CNA, General Contractor or installer will contact distributor and purchase product.

1) CNA contacts Rinnai at 1.866.383.0707 and follows prompts to Service.

2) Rinnai will provide CNA with Authorized Service Providers (ASP) in the arae of the facility.

3) CNA will contact the ASP to maintain or service the product.

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

203

0 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

30

339

678/ 336-8503 T

ELE

PH

ON

E

678/ 33

6-85

08 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

Page 10: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

T

MV 1

3/4" HW

1/2" HW

3/4" CW

1" CW

3/4" CW1" HW

WATER SERVICESUBMETER

EXISTING WATER SERVICE ABOVECEILING. VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS

NEW GAS SERVICE ON ROOF, FROMNEW GAS METER AND REGULATOR.VERIFY LOCATION AND CONNECTIONREQUIREMENTS, PROVIDE WITH ROOF

NEW GAS SERVICE ON ROOF,ROUTE DOWN TO CEILING SPACE.

PIPE SUPPORTS.

NEW GAS SERVICE ON ROOF,ROUTE TO ROOFTOP A/C UNITS

1/2" CW

T

FS 2S 2

WH 1 2

S 3

9 10 9

S 16

9

3

HD 1

1 7 12

GI 1

L 1

WC 1

FD 1 FD 1

11 9 9

9

8

EXISTING SANITARY WASTE SERVICE BELOWGRADE. VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS

5

5 54

P2.0

PLUMBINGPLANS

PLUMBING WASTE AND VENT PLAN 1/4"=1'-0" A

PLUMBING WATER AND GAS PLAN 1/4"=1'-0" C

ROUTE EVAPORATOR COIL CONDENSATE DRAIN WITH PROPER SLOPE TO HUB DRAIN1

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

203

0 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

30

339

678/ 336-8503 T

ELE

PH

ON

E

678/ 33

6-85

08 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

KEY NOTES B

KEY NOTES D

10

VERIFY METER LOCATION AND CAPACITY WITH LOCAL GAS

LEG, UNION, AND VALVE AT UNIT.

HEATER. PIPE RELIEF TO MOP SINK.

2" GAS DOWN TO OVENS, SEE OVEN GAS PIPING DETAIL 3/P3.0.

1" HOT AND COLD WATER, 1-1/4" GAS DOWN TO GAS WATER

GAS LINE UP THRU ROOF TO ROOFTOP UNIT. INSTALL DRIP

COMPANY. ROUTE NEW 2" LINE TO SPACE AS REQUIRED.

9

8

7

6

5

4

3

2

1

DO NOT ROUTE ANY PIPING OVER ELECTRICAL PANELS.

WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISH CEILING. UNDER

ALL DETAILS.

3/4" HOT AND COLD WATER DOWN IN WALL TO 3-COMPARTMENT SINK. INSTALL WATTS NO. 9N BACKFLOW PREVENTER FOR EACH WATER LINE CONNECTION TO FAUCET. INSTALL EXACTA SANITIZER DISPENSING

PROVIDE 3/4" HOT WATER TO DISHWASHER/BOOSTER HEATER.CONTRACTOR SHALL PROVIDE AND INSTALL WATER HAMMER ARRESTOR(PDI SIZE A, ASSE 1010) AND 25 PSI PRESSURE REGULATING VALVEWITH INTERNAL THERMAL EXPANSION BY-PASS ON SUPPLY LINE. CONTRACTOR SHALL INSTALL VACUUM BREAKER AND ALL ACCESSORIESPROVIDED WITH DISHWASHER PER MANUFACTURER'S REQUIREMENTS.

THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FORROUTING AND CONNECTION OF WATER AND GAS SERVICE.

CONNECT NEW 1" COLD WATER LINE TO EXISTING WATER SERVICELINE ABOVE CEILING. FIELD VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS.

ROUTE HOT AND COLD WATER ABOVE CEILING, BELOW BUILDING INSULATION.

MACHINE OUTLET AND SHUT-OFF VALVE AT 12" A.F.F.PROVIDE T&S "SAFE-T-LINK" CW-4B-60, 3/8", 5 FT. COILED STAINLESSSTEEL BRAIDED HOSE WITH EXTRUDED COATING - T&S AW-5B-SS 3/8" STAINLESS STEEL QUICK DISCONNECT TO CONNECT TO HOT HOLDCABINET WATER CONNECTION PER MANUFACTURER'S INSTRUCTIONS.

12

KNEE PEDAL CONTROL. 1/2" COLD AND TEMPERED WATER DOWN IN WALL TO HAND SINK WITH

TEMPERING MIXING VALVE ABOVE CEILING. REFER TO DETAIL 9/P3.0.

11

SLAB DISTIBUTION ALLOWED AT CONTRACTOR OPTION. COORDINATE

VENDOR INSTALLS EXACTA SYSTEM AT MOP SINK, PR DETAIL 2/P3.0.13

SYSTEM PER DETAIL 10/P3.0.

14

15

THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR ROUTINGAND CONNECTION OF WASTE LINES. ALL FIXTURE DRAINS AND TRAPS TOBE VENTED AS PER LOCAL CODE.

WITH 1/2" FOAM RUBBER PER SPECIFICATIONS. SEE DETAIL 5/P3.0.ELECTRICAL HEAT TAPE ON DRAIN LINE IN FREEZER. INSULATE DRAIN LINESMINIMUM OF 74" A.F.F. TO AVOID CONFLICT WITH SHELVING. PROVIDECLOSE TO FREEZER/COOLER CEILING AS POSSIBLE. DRAIN LINE SHALL BE AAND PROVIDE PROPER AIR GAP. CONDENSATE DRAIN LINES SHALL BE ROUTED ASROUTE EVAPORATOR COIL CONDENSATE DRAIN WITH PROPER SLOPE TO HUB DRAIN

VERIFY EXACT LOCATION AND CONNECTION REQUIREMENTS.CONNECT NEW WASTE TO EXISTING WASTE BELOW FLOOR AS REQUIRED.

FLOOR DRAIN SHALL BE INSTALLED FLUSH WITH FINISHED FLOOR.DO NOT SLOPE FLOOR TO DRAIN.

DETAIL 6/P3.0.CONDENSATE DRAIN LINE UP TO ROOFTOP UNIT. REFER TO

PROVIDE INDIRECT WASTE CONNECTION FROM 3-COMPARTMENT SINK

1-1/4" CONDENSATE DRAIN DOWN IN WALL AND TERMINATE ABOVE MOPSINK WITH PROPER AIR GAP.

PROVIDE INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK WITH PROPERAIR GAP.

TO FLOOR SINK WITH PROPER AIR GAP.

PROVIDE FLOOR SINK IN LIEU OF HUB DRAIN WHERE REQUIRED BY LOCALCODES.

ROUTE DRAIN LINE FROM BOOSTER HEATER TO FLOOR SINK WITH PROPERAIR GAP.

13

12

11

8

7

10

6

5

4

3

2

1

SCHEDULE 40 PVC DWV OR AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.AND OUTLET OF INTERCETOR TO CONNECTION AT SANITARY MAIN SHALL BE ENTIRE RUN OF DRAIN LINES TO INLET OF GREASE INTERCEPTOR

PROVIDE TRAP PRIMER TO HUB/FLOOR DRAIN/SINK. REFER TODETAIL 1/P3.0.

9

PROVIDE 1/2" CW CONNECTION TO DISH MACHINE VENTLESS HOOD AS REQUIRED BY MANUFACTURER.

16

FOR PROPER DRAINAGE FROM HOOD PER MANUFACTURER'S REQUIREMENTS.VERIFY DRAIN CONNECTION FROM VENTLESS HOOD TO DISHMACHINE

1/2" COLD WATER LINE DOWN IN WALL, PROVIDE RECESSED WASHING

Page 11: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

P3.0

PLUMBINGDETAILS &

GAS ISOMETRIC N.T.S. 11

TEMPERING VALVE DETAIL N.T.S. 9

3-COMP SINK EXACTA SYSTEM DETAIL N.T.S. 10

WASTE ISOMETRIC N.T.S. 12

COOLER/FREEZER PIPING N.T.S. 5 TRAP PRIMER DETAIL N.T.S. 1

RTU COND. DRAIN DETAIL N.T.S. 6 MOP SINK DETAIL N.T.S. 2

OVEN GAS PIPING DETAIL N.T.S. 3

NOT USED N.T.S. 4

WH 1

CLEANING SOLUTIONDISPENSER BAGS, (SANITIZER)PROVIDE BY ECOLAB.

WASH RINSE SANITIZE

PROVIDE ANTI-SIPHON DEVICE ORBACKFLOW PREVENTER AS REQUIREDBY ATHORITY HAVING JURISDICTION.

PROVIDE ANTI-SIPHONDEVICE OR BACKFLOWPREVENTER AS REQUIREDBY ATHORITY HAVINGJURISDICTION.

COLD WATER SUPPLY

GAS SUPPLY

Rinnai

Water Heater

HOT WATERTO OUTLETS

Rinnai

Water Heater

PRIMARY Sub

WATER HEATER DETAIL N.T.S. 7

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

20

30

P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

303

39

678/ 336-8503 T

ELE

PH

ON

E

67

8/ 336

-85

08 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

FS 2

S 2

FCO 1

HD 1 9

WC 1

FD 1

S 1

GI 1

FCO 1

FD 1

LAV 1

S 1

FD 1

FLOOR SINK AS

LOCATED ON PLANS.

GREASE INTERCEPTOR WITH

BUILT-IN FLOW CONTROL.

GREASE INTERCEPTOR IS RATED AND MANUFACTURED WITH AN

INTERNAL FLOW CONTROL SYSTEM ALREADY IN PLACE. THEY

DO NOT REQUIRE AN EXTERNAL FLOW CONTROL FITTING.

DISHWASHER

LOCATION

UNDER SLAB PIPING

FROM ADJACENT

DRAINS.

Page 12: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

5.

4.

15.

14.

12.

13.

11.

10.

3.

2.

1.

7.

9.

6.

8.

16.

17.

18.

ELECTRICAL CONTRACTOR SHALL PROVIDE DUCT DETECTORS IN QUANTITYAS SHOWN ON THE PLANS FOR ALL AIR-MOVING SYSTEMS PRODUCING 2000CFM OR GREATER. DUCT DETECTOR SHALL BE INSTALLED IN THE SUPPLYDUCT OF THE INDICATED UNIT. DUCT DETECTOR SHALL BE "SIMPLEX TRUEALARM" #4098-9687 OR EQUAL WITH #4098-9842 CONTROL STATION PERDUCT DETECTOR SHOWN. THE DUCT DETECTOR AND THE CONTROL STATIONSHALL BE WIRED AS DESCRIBED IN THE MANUFACTURER'S LITERATURE.ALARM LIGHT AND PIEZO SHALL OPERATE IN ALARM CONDITION. THE'POWER' LIGHT SHALL OPERATE AT ALL TIMES AND EXTINGUISHING OFTHIS LIGHT SHALL INDICATE TROUBLE OR FAULT WITH THE SYSTEM. APLACARD SHALL BE INSTALLED ABOVE THE CONTROL STATION MODULE THATREADS "DUCT DETECTOR TROUBLE IF GREEN LIGHT IS NOT ON, CALL FORSERVICE". THIS SYSTEM SHALL BE INSTALLED TO COMPLY WITH NFPA 90A4-4 REQUIREMENTS. VERIFY NFPA 90A 4-4 CODE REQUIREMENTS PRIOR TOINSTALLATION.

19.

SMOKE MONITORING SYSTEM 7

ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONALELECTRIC CODE (NEC), THE AMERICANS WITH DISABILITIES ACT (ADA), AND ALL STATEAND LOCAL REQUIREMENTS AND CODES.

REFER TO RELATED ARCHITECTURAL, MECHANICAL, AND STRUCTURAL DRAWINGS FORRELATED INFORMATION.

THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THEEQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALLVERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILUREOF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITYFOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.

SEPARATE GREEN GROUND CONDUCTOR SHALL BE ROUTED IN ALL CONDUITS WITH ALLPHASE CONDUCTORS.

ISOLATED GROUND FOR P.O.S. SYSTEM SHALL BE CONTINUOUS FROM LAST OUTLET TOPANEL. DEDICATED CIRCUIT WITH SEPARATE ISOLATED GROUND WITH LESS THAN 0.5OHM IMPEDANCE. TERMINATE AT NEUTRAL TO GROUND BUS BAR INSIDE THE MAINSOURCE PANEL.

ALL MECHANICAL EQUIPMENT SHALL BE COMPLETELY CONNECTED BY ELECTRICALCONTRACTOR INCLUDING BOTH POWER AND CONTROL WIRING. ELECTRICALCONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THEREQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING ANDCONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS.

BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS FOR CLARITY ONLY,ELECTRICAL CONTRACTOR MAY GROUP SINGLE POLE BRANCH CIRCUITS IN MULTIPLECIRCUIT HOME RUNS. (3 CIRCUITS MAX @ 120/208V 3Ø, 2 CIRCUITS MAX @ 120/240V. 3Ø &1Ø). A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER,RECEPTACLE, AND LIGHTING CONDUITS.

ALL EXTERIOR CONDUIT FOR ROOF MOUNTED EQUIPMENT AND WIRING SHALL BEMINIMIZED BY ROUTING IN CEILING SPACE. NO EXTERIOR CONDUIT WILL BE ACCEPTED.

ALL CONDUITS SHALL BE CONCEALED IN WALL SPACE, CEILING SPACE OR UNDER FLOOR,NO EXPOSED CONDUIT PERMITTED.

ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL CONDUIT FOR LOW VOLTAGEWIRING. LABEL CONDUIT TO IDENTIFY ITS INTENDED USE (I.E.: CONTROL, SECURITYSYSTEM, PHONE, DATA, ETC.).

WHEN ALUMINUM CONDUCTORS ARE PRESENT, E.C. SHALL VERIFY ALL CONNECTIONSAND REPLACE AS REQUIRED

COMPLETE SYSTEM SHALL BE GROUNDED PER N.E.C. ARTICLE 250..

FINAL CONNECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITHU.L. APPROVED LIQUID TIGHT CONDUIT. PROVIDE WITH GROUND WIRE SIZED PER N.E.C.ART. 250 (1999).

WIRE CONNECTION FROM JUNCTION BOX TO LAY-IN LIGHT FIXTURES MAY BE ENCASED INFLEXIBLE CONDUIT 6'-0" MAXIMUM

BUILDING SIGNAGE CONNECTIONS INDICATED ON LIGHTING PLAN.

ALL EXISTING ELECTRICAL FIXTURES, DEVICES AND CIRCUITING NOT RELOCATED ORREUSED SHALL BE REMOVED BACK TO POINT OF SUPPLY.

E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING TO COMPLY WITHN.F.P.A. 96.7-3.1.3 FOR POWER SHUTOFF ON ALL ELECTRICAL EQUIPMENT UNDER OVENHOOD. VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHINGSYSTEM SUPPLIER. PROVIDE ONLY IF REQUIREDBY LOCAL CODE.

WESTERN REGION STANDARD MAIN PANEL RATING IS 42KAIC. WHEN GE MAIN PANEL ISUSED IN WESTERN REGION - RATING SHALL BE 65KAIC.

EASTERN REGION MAIN PANEL SHALL BE 22KAIC.

SMOKE DETECTOR WIRING 6

ALARM CONTACTS

JUMPER

RTU TERMINAL STRIP(LTB1)

SMOKE DETECTORS LOCATEDIN SUPPLY AND RETURN AIRDUCTS. INCLUDE IN SUPPLYDUCTS ONLY WHEREREQUIRED BY LOCAL CODE.WIRE TO SHUTDOWN AC UNITUPON DETECTION OF SMOKE.

24 VAC

REMOVEJUMPER1

HOOD WIRING DIAGRAM 8

POWER OUTTOSTARTER/CONTACTOR,ECT.

LIGHTMASTER LS2 DARKSENSOR PHOTOCELL

A-14

A-28

A-18

EXTERIOR SIGNAGE

SPACE

SHOW WINDOW RECEPTS

SWITCH LOCATED ATFRONT OF HOUSE

LIGHTING CONTROL DIAGRAM 4

A-19

A-20

INTERIOR LIGHTS

COOLER/FREEZER LIGHTS

INTERIOR LIGHTS

HVAC THERMOSTATA-14

A-24

LIGHTING CONTROL SEQUENCE OF OPERATION:

PRIOR TO OPENING FOR BUSINESS , CONTROL SWITCH FRONT OF HOUSE ISACTIVATED, INITIATING THE "OCCUPIED" MODE , SINGLE POLE SWITCH SHALL ENERGIZEBOTH CONTACTORS 'C1' AND 'C2'.

CONTACTOR 'C2' IS TO PROVIDE 'ON-OFF' CONTROL TO THE KITCHEN LIGHTS, FRONTLIGHTS, COOLER/FREEZER LIGHTS AND HVAC THERMOSTAT.

CONTACTOR 'C1' SHALL BE ENERGIZED TO PROVIDE CONTROL TO THE EXTERIORSIGNAGE AND THE SHOW WINDOW RECEPTACLES. THIS CONTACTOR IS CONTROLLEDTHROUGH THE PHOTOCELL NOTED. THIS PHOTOCELL IS TO TURN ON THE LIGHTS ATDUSK, SWITCH IS TO BE USED TO TURN OFF THE LIGHTS AT CLOSING.

'C2''C1'

FRANCHISE SUPPLY OF ELECTRICAL SWITCHGEAREQUIPMENT IS FROM ACCUSERV.

THE ACCUSERV SWITCHGEAR IS TO BE PURCHASEDTHROUGH APPROVED YUM SYSTEM DISTRIBUTION.THE GENERAL CONTRACTOR IS RESPONSIBLE FORINSTALLATION OF THE SYSTEMS DESCRIBED IN THEPLANS. FRANCHISEES SHOULD CONTACT THEIRAPPROVED YUM SYSTEM DISTRIBUTOR FOR A PRICEQUOTE AND A BILL OF MATERIAL CONFIRMATION FORTHEIR SPECIFIC PROJECT. SEE THE SWITCHGEARSECTION IN THE SCOPE OF WORK FOR ADDITIONALINFORMATION.

PRIMARY CONTACT: BUDDY BOCKWEGPHONE: (877) 707-7378FAX: (502) 961-0357EMAIL: [email protected]

THE ACCUSERV SWITCHGEAR PACKAGE CONSISTS

OF SERVICE ENTRANCE, SWITCHGEAR, MAIN

PANELS, SUB PANELS, LIGHTING CONTACTORS AND

ALL ASSOCIATED PRODUCTS TO COMPLIMENT THE

SWITCHGEAR PACKAGE.

BE PREPARED AT TIME OF ORDER OR QUOTE REQUESTTO PROVIDE ALL PROJECT DETAILS REGARDINGSPECIFICATIONS AND QUANTITIES AS SITE SPECIFICDESIGN MAY NOT MATCH PROTOTYPICAL DESIGN.

CORPORATE NATIONAL ACCOUNT AGREEMENT IS WITHGEXPRO (formally GE Supply) FOR THE SUPPLY ANDDISTRIBUTION OF ELECTRICAL SWITCHGEAR EQUIPMENTFOR COMPANY DEVELOPMENT ONLY .

UNDER THIS AGREEMENT, THE CONTRACTOR ISRESPONSIBLE FOR PURCHASE AND INSTALLATION OFTHE SYSTEMS DESCRIBED IN THE PLANS. ALL COMPANYPROJECTS MUST CALL GEXPRO's NATIONAL ACCOUNTDEPARTMENT FOR A PRICE QUOTE AND A BILL OFMATERIAL CONFIRMATION FOR THEIR SPECIFIC PROJECT.SEE THE SWITCHGEAR SECTION IN THE SCOPE OF WORKFOR ADDITIONAL INFORMATION.

PRIMARY CONTACT: MIKE URKOSKIPHONE: (630) 718-6529FAX: (630) 718-6567EMAIL: [email protected]

THE GEXPRO SWITCHGEAR PACKAGE CONSISTS OF

SERVICE ENTRANCE, SWITCHGEAR, MAIN PANELS,

SUB PANELS, AND LIGHTING CONTACTORS. GEXPRO

IS ALSO ABLE TO SUPPLY A FULL LINE OF GEXPRO

AND NON-GEXPRO PRODUCTS TO COMPLIMENT THE

SWITCHGEAR PACKAGE.

BE PREPARED AT TIME OF ORDER OR QUOTE REQUESTTO PROVIDE ALL PROJECT DETAILS REGARDINGSPECIFICATIONS AND QUANTITIES AS SITE SPECIFICDESIGN MAY NOT MATCH PROTOTYPICAL DESIGN.

CORPORATE DEVELOPMENT

NATIONAL ACCOUNTS: SWITCHGEARINSTALL STANDARD PACKAGE. SUPPLY and INSTALL NON-STANDARD COMPONENTS.

FRANCHISE DEVELOPMENT

EXTERIOR WALL INTERIOR

4 #500 KCMIL IN 4" C.

4 #500 KCMIL & 1 #3 GRD. IN 4"C.

METER AND C.T. CABINETPER UTILITY COMPANYSTANDARDS.

400A., 3P., 240V., DISC. SW. FUSEDAT 400A. NEMA-3R, S.E. RATED.

1 #6 - 3/4" C. TO 3/4" DIA. X 10'-0"LONG COPPERCLAD GROUND ROD WITH"CADWELD" CONNECTION.

1 #1/0 - 3/4" C. TO WATER SERVICEWHERE SERVICE ENTERS BLDG. ANDOTHER GROUNDING ITEMS SPECIFIEDIN N.E.C. ARTICLE 250-50.

4 #500 KCMIL IN 4" C.(400A. SERVICE)

4 #500 KCMIL, 1 #3 GRD. & 1 #3 ISO. GRD. - 4"C.

PROVIDE PANEL 'A' WITH DOUBLE LUGS.

VERIFY EXISTING SERVICE ENTRANCECONDUCTORS FOR NEW LOAD. PROVIDEPIZZA HUT CONSTRUCTION PROJECTMANAGER WITH WRITTEN VERIFICATION.

GROUNDING NOTE: VERIFY EXISTING SYSTEM ISGROUNDED PER N.E.C. ART. 250. UPGRADE ASREQUIRED. CONNECT NEW SYSTEM TO EXISTINGGROUND.

ELECTRICAL DISTRIBUTION EQUIPMENT SHOWN IN LIGHT PEN IS EXISTING.

ELECTRICAL RISER DIAGRAM NOTES:

1.

NOTE: INFORMATION ON PLANS REGARDING ELECTRICAL DISTRIBUTION EQUIPMENT WAS

BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. E.C. SHALL VERIFY

EXISTING CONDITIONS. NOTIFY PIZZA HUT CONSTRUCTION PROJECT MANAGER IMMEDIATELY

OF ANY DISCREPANCY AFFECTING THE INTENT OF THE DESIGN CONVEYED HEREIN.

PROVIDE #1/0 CU. - 3/4" C. TOBOND GAS, WATER AND SPRINKLERPIPING PER N.E.C. ARTICLE 250-104

400A., 120/208V., 3Ø, 4W. ELECTRICAL SERVICE.2.

NEUTRAL BUS AND GROUND LUG IFREMOVE MAIN BONDING JUMPER BETWEEN

EXISTING SERVICE EQUIPMENT NEUTRALIS ALREADY BONDED PER N.E.C.

'B'

PANEL

'A'

PANEL GC SHALL VERIFY WITH LOCALAUTHORITY HAVING JURISDICTION IFELECTRICAL DISCONNECT IS REQUIRED.

FROM POLE MOUNTEDTRANSFORMER

NEW OVERHEAD SERVICE

(SEE SITE PLAN E5.0)

SPACE

E1.0

SCHEDULES, NOTES AND

ELECTRCALDELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

2030 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

3033

9

678/ 3

36-8

503 T

ELE

PH

ON

E

678

/ 336

-850

8 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

Page 13: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

TT

B:9

18"

13

18"

B:15

A:17

A:7

A:25

WP/GFIA:23

A:11 A:3

18" 18"

A:37 A:31

18"

B:1

3 #6, #10 GRD., 1" C.

8

A:27

18"

A:5

18"

A:12

9

B:2

A:8

18"11

11

A:9

18"

12

CE

-1

5

CC-1

B-14/16/18

FC-1

4

FE-1

A-38/40/42 A-29

EF-1A-29

7

13A:25

A:27

B:8

10

A:15

17

166

18

A:15

RTU 01

RTU 02

EQ EQ

E2.0

ELECTRICALPOWER PLAN

1

2

3

ALL CONNECTIONS AND ELECTRICAL EQUIPMENT LISTED IN SCHEDULE SHALL BEPROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. FIELD VERIFYCONNECTION REQUIREMENTS AND EQUIPMENT PROVIDED BY OTHERS PRIOR TOROUGH-IN.

REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTSASSOCIATED WITH WIRING AND CONNECTIONS OF INTERLOCKING, THERMOSTATLOCATIONS, EXHAUST FAN CONTROL SWITCHES, AND OTHER CONTROLS OFMECHANICAL EQUIPMENT.

PROVIDE DUCT MOUNTED SMOKE DETECTORS IN THE SUPPLY DUCT. VERIFY THEREQUIRED QUANTITY OF DUCT SMOKE DETECTORS FOR EACH UNIT WITH DUCTWORKLAYOUT TO MEET NFPA REQUIREMENTS. REFER TO SMOKE MONITORING SYSTEMNOTES ON SHEET E1.0.

ELECTRICAL POWER PLAN 1/4"=1'-0" 1

KEYED NOTES 24MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES 5

15

14

13

12

11

10

9

8

7

6

1

2

3

4

5

3

A. HORIZONTAL DIMENSIONS TO J-BOXES ARE FROM FACE OF STUD CENTER OF BOX, U.O.N.VERTICAL DIMENSION OF 18" IS FROM FINISH FLOOR TO CENTER OF J-BOX, U.O.N.

B. PROVIDE BLACK OUTLETS, SWITCHES AND COVER PLATES IN F.O.H.

C. ALL OUTLETS AND J-BOXES BEHIND SIGNAGE SHALL BE RECESSED OR FLUSH WITH ADJACENT BUILDING SURFACES.

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

ELO

PM

EN

T

203

0 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 204

AT

LA

NT

A, G

EO

RG

IA

30

339

678

/ 336-8503

T

ELE

PH

ON

E

678/ 33

6-8

508 F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

16

17

18

19

20

21

22

23

24

25

PROVIDE 20A., 120V. A QUAD ISOLATED GROUND RECEPTACLE FOR DE-MARK TELEPHONE TERMINALBOARD AND TELEPHONE SYSTEM TERMINAL BOARD.

PROVIDE 120V CONNECTION FOR FREEZER DOOR HEATER, CONDENSATE HEAT-TRACE AND HEAT AIRRELIEF VENT IN FREEZER. PROVIDE CONNECTIONS PER MANUFACTURERS REQUIREMENTS AND N.E.C.ARTICLE 300-7 (2008).

PROVIDE CORD & PLUG FOR VENT-LESS HOOD AND CONNECT AS REQUIRED. VENT-LESS HOOD HASINTERLOCK FOR FRYER, WIRE FRYER INTO VENT-LESS HOOD SYSTEM.

CONTRACTOR TO PROVIDE SINGLE POINT CONNECTION TO FREEZER CONDENSING UNIT (FCU) ANDCIRCUIT AS INDICATED. E.C. TO CONNECT PROVIDED WIRING HARNESS THAT INTERCONNECTS FCUAND FREEZER EVAPORATOR AS REQUIRED BY MANUFACTURER. INSTALL PER NEC 430-102 AND 300-7(2008).

CONTRACTOR TO PROVIDE SINGLE POINT CONNECTION TO COOLER CONDENSING UNIT (CCU) ANDCIRCUIT AS INDICATED. E.C. TO CONNECT PROVIDED WIRING HARNESS THAT INTERCONNECTS CCUAND COOLER EVAPORATOR AS REQUIRED BY MANUFACTURER. INSTALL PER NEC 430-102 AND 300-7(2008).

OVENS - 2P30A., 240V., MANUAL MOTOR STARTING SWITCH WITHOUT OVERLOADS WITH STAINLESSSTEEL LOCKOUT AND TAG OUT COVER PLATE. E.C. TO MAKE FINAL CONNECTION TO EXHAUST FAN EF-1FROM SWITCH. E.C. TO PROVIDE RECEPTACLES TO MATCH OVEN PLUG CONFIGURATION IF OVENS AREPROVIDED WITH FACTORY INSTALLED CORD AND PLUG.

SEE DRAWING SHEET E1.0 F0R EXHAUST FAN INTERLOCK DETAILS.

DISHWASHER - 60A., 3P., 240V., MANUAL MOTOR STARTING SWITCH WITHOUT OVERLOADS WITHSTAINLESS STEEL LOCKOUT AND TAG OUT COVER PLATE.

PROVIDE QUAD OUTLET TO ACCOMMODATE CURRENT CSR STATION AND ALLOW FOR FUTURE CSRSTATION, TO BE ADDED AT A LATER TIME.

1P20A, 115V, 3 WIRE ISOLATED GROUND RECEPTACLE, NEMA 5-20P LOCATED WITHIN 11" OFCENTERLINE OF COUNTER.

1P20A., 115V., 3 WIRE RECEPTACLE, NEMA 5-20P.

1P30A., 120V., 2 WIRE NEMA L5-30P RECEPTACLE.

PROVIDE CONNECTION FROM DUCT SMOKE ANNUNCIATORS TO DUCT SMOKE DETECTORS.SEE SMOKE MONITORING SYSTEM NOTE SHEET E1.0.

FIRE SUPPRESSION SYSTEM IS INTEGRAL WITH VENT-LESS HOOD.

RECEPTACLE TO BE PROVIDED ONLY WHEN CCTV EQUIPMENT IS REQUIRED. MOUNTRECEPTACLE AT 90".

PROVIDE SINGLE POINT CONNECTION TO AIR HANDLER ABOVE CEILING AND CIRCUIT ASINDICATED.

PROVIDE 3P60A FUSIBLE DISCONNECT FOR CONDENSING UNIT IN NEMA-3R ENCLOSURE.CONTRACTOR TO MAKE FINAL CONNECTION TO CU FROM DISCONNECT.

PROVIDE WEATHERPROOF GFI SERVICE RECEPTACLE FOR CONDENSING UNITS.

BREAKERS FOR DEVICES UNDER HOOD ARE TO BE PROVIDED WITH SHUNT TRIP RELAY.

CONTRACTOR TO PROVIDE RECEPTACLE FOR FUTURE PROOFER.

CONTRACTOR TO PROVIDE RECEPTACLE RECESSED IN CEILING FOR FUTURE DISPATCH.

EDWARDS CAT. NO. 44 ROLLING BALL CONTACTOR MOUNTED IN DOOR FRAME FORACTIVATION OF DOOR CHIME. INSTALL PER MANUFACTURER'S INSTRUCTIONS. J-BOXMINIMUM 2 1/4" DEEP AND MOUNT ABOVE CEILING. INSTALL PER

EDWARDS CAT. NO. 338-G5 SINGLE-STROKE WALL MOUNTED CHIME. PROVIDE 4" OCTAGONOR SQUARE BOX (TYP. OF 2). INSTALL PER MANUFACTURER'S INSTRUCTIONS.

EDWARDS CAT. NO. 590 CLASS 2 SIGNALING TRANSFORMER AND EDWARDS 593TRANSFORMER MOUNTING PLATE FOR DOOR CHIME SYSTEM. PROVIDE TWO GANGMANUFACTURER'S INSTRUCTIONS.

PROVIDE 24 VOLT LOW VOLTAGE WIRING PER MANUFACTURES REQUIREMENTS. CONNECTAND INSTALL PER MANUFACTURER'S INSTRUCTIONS. PROVIDE CONDUIT FOR LOW VOLTAGEWIRING IF REQUIRED BY LOCAL CODE.

50 NEMA 3R

2020 1 FUSTAT

PANEL DEVICEPOLE

OP

LE

DEVICE AT UNIT

OTHER

SETS

REMARKS

NOTES BELOW

FEEDER DESCRIPTION

RTU ROOF TOP UNIT1 208/3 - - - B-2/4/6

EF EXHAUST FAN1 120/1 .75 13.8 1.656 A-292 120/1 .17 4.4 0.528 A-2034

UNIT

VOLTAGE

UNIT

DESIG.

LOAD

H.P. FLA KVACIRCUIT

NUMBEROR SEE PANEL SCHEDULES

20CCE COOLER CONDENSER & EVAPORATOR1 208/3 13.0 5.4 B:16/18/20

FCE FREEZER CONDENSER & EVAPORATOR1 208/3 3.8 5.4 A:38/40/42 20

50 NEMA 3R2 208/3 - - - B-8/10/12

Page 14: cc-m1.comcc-m1.com/usersfiles/Leesport Pa.pdf · to roof cap ventless fryer hood system 1 12x8 s-2600 s-2600 ... door undercut (3/4" minimum) flexible duct ... is intermittent, and

T

A

A

3B

3B

L2

L

A:19

1

95

A:18

WP A:28J

5

4

A:24

A:14

A:38

145

A

A

A AA

A

A2 A2

1

A:209

T

S176"

S176"

70"

24"

60"

PATCH PANEL2 COMPUTER

78"

1

18"

S4

J116"

24"

3

3

2

S4

E3.0

ELEC LIGHTING

PLAN

TELEPHONE COMPANY DEMARK BOARD - PROVIDE (1) 2" CONDUIT WITH PULLSTRING FROM TELEPHONE TERMINAL BOARD TO TELEPHONE SERVICE ENTRANCE.PROVIDE SWEEPING 90° ELBOWS AT ALL TURNS. VERIFY SITE AND TELEPHONECOMPANY REQUIREMENTS PRIOR TO BIDDING. SEE ARCHITECTURAL ELEVATIONDETAIL FOR SIZE AND MOUNTING.

PROVIDE (1) 2" CONDUIT WITH PULL STRING STUBBED UP ABOVE TO ACCESSIBLECEILING FROM J-BOX AT COMPUTER WALL CABINET FOR DATA CABLES. PROVIDESWEEPING 90° ELBOWS AT TURNS.

PROVIDE (1) PULL STRING STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM EACHVOICE, VOICE/DATA AND DATA OUTLET.

TELEPHONE TERMINAL BOARD FOR PIZZA HUT TELEPHONE SYSTEM. SEEARCHITECTURAL ELEVATION DETAIL FOR SIZE AND MOUNTING.

REQUIREMENTS WITH SECURITY PROVIDER.

REQUIREMENTS WITH SECURITY PROVIDER.HOLD UP BUTTON BY MANAGER DESK. VERIFY EXACT LOCATION AND

NOT USED.

HOLD UP BUTTON LOCATION (MOUNT 2 1/2" BEHIND COUNTER EDGE). VERIFY

KEYED NOTES 2

LIGHTING PLAN 1/4"=1'-0" 1

OVERHEAD TELEPHONE BELL PROVIDED BY PHONE INSTALLER.

REQUIREMENTS WITH SECURITY PROVIDER.CONDUIT THROUGH WALL, STUB UP ABOVE CEILING. VERIFY EXACT LOCATION ANDHOLD UP BUTTON ABOVE COOLER/FREEZER DOORS. MOUNT AT TOP OF JAMB WITH

KEY NOTES B

1

2

3

4

5

S1

S2

S3

S4

K

A

NO. LOCATION MANUFACTURER / ITEM NUMBER FIXTURE TYPE / BALLAST

ACRYLIC LENS

SUPPLIED W/ FIXTURE

F32T8 LAY-IN GRID

MOUNTING VOLTAGE W REMARKS

KITCHEN 120 96

CEILING EXIT FIXTURE WITH EMERGENCY BATTERY. SEE FIXTURE SCHEDULE NOTE #2.3

LIGHTOLIER / XP2GVA232120SO

LITHONIA / L Q M S W 3 R ELN

2' X 4' TROFFER / ELECTRONIC

LED EXIT / -

3

- 120ENTRY

TYPE#LAMPS

A2 ACRYLIC LENS, 'PROVIDE WITH EMERGENCY BATTERY BACK-UPF32T8 LAY-IN GRIDKITCHEN 120 96THOMAS/ CM6/ FV26/ V65B/ BH3 2' X 4' TROFFER / ELECTRONIC 3

L F32T8 SIGN MOUNTED ABOVE ARCHITECTURAL CLOUD, VERIFY MOUNTING LOCATION64SIGN LIGHT 4' FLUORESCENT / ELECTRONIC 2 120ENTRY

F25T8 SIGN MOUNTED ABOVE ARCHITECTURAL CLOUD, VERIFY MOUNTING LOCATION6412023' FLUORESCENT / ELECTRONICSIGN LIGHTENTRYL2

1

LIGHTING NATIONAL ACCOUNT:ACCUSERV LIGHTING:

ACCUSERV HAS AGREED TO PROVIDE A PHOTOMETRICS STUDIES FOR ALL DELCOS. ONCE AN EQUIPMENT PLAN IS COMPLETE, EMAIL THE AS-BUILT AND BASE PLANS TOACCUSERV FOR PHOTOMETRIC. EACH SPACE WILL BE DESIGNED FOR A MIN. OF 50

PRIMARY CONTACT: BUDDY BOCKWEGPHONE: (877) 707-7378FAX: (502) 961-0357EMAIL: [email protected]

FOOT CANDLES THROUGH OUT THE SPACE. ACCUSERV HAS AGREED TO RETURN THE PHOTO METRIC WITH LIGHTING LAYOUT WITHIN 48 HOURS.

1

2

3

4

5

6

7

8

9

10

B 13W CFL RECESSED --26LYTECASTER / 1113CFL RECESSED DOWN LIGHTING 2 120FRONT COUNTER

DELCO LT

PLOT DATE:

PIZZA HUT

CONTRACT DATE:

BUILDING TYPE:

PLAN VERSION:

SITE NUMBER:

STORE NUMBER:

LIS PROJECT:

DELCO LT

09-11.01.09

307351

2010YB017

5479 POTTSVILLE PIKELEESPORT, PA 19533

arch

ite

ctu

re

AR

CH

IT

EC

TU

RE

EN

GIN

EE

RIN

G

LA

ND

D

EV

EL

OP

ME

NT

2030 P

OW

ER

S F

ER

RY

R

OA

D

SU

IT

E 2

04

AT

LA

NT

A, G

EO

RG

IA

30339

67

8/ 33

6-85

03 T

EL

EP

HO

NE

678/ 336-8508

F

AC

SIM

ILE

OS

WE

LL

+

N

IT

IS

HIN

SUPPLIED W/ FIXTURE TRACK --641203TRACK HEADSWAC LIGHTING/ LHT826BN/ WTENTRYL3

- - ---120-4' TRACKLIGHTOLIER/ 6004WHENTRYLB

PROVIDE TWO (2) 2-GANG JUNCTION BOXES FOR ALL LOW VOLTAGE CABLING.6

PROVIDE (2) PULL STRINGS STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM EACH OFTWO VOICE, VOICE/DATA AND DATA OUTLETS. BOTH OUTLETS TO BE MOUNTED AT 24" AFF.

7

PROVIDE (1) PULL STRING STUBBED UP ABOVE ACCESSIBLE CEILING FROM FUTURE VOICE AND DATA OUTLET. OUTLET TO BE MOUNTED IN CEILING FOR FUTURE DISPATCH USE.

8