cc-m1.comcc-m1.com/usersfiles/leesport pa.pdf · to roof cap ventless fryer hood system 1 12x8...
TRANSCRIPT
T
EF 01
EF 02
EXHAUST DUCT, UP THRU ROOF
6"Ø
TO ROOF CAP
VENTLESS FRYERHOOD SYSTEM
1
12x8
S-2 600
S-2 600
S-1 50
S-2 550
S-2 400
24x14
24x14
6"Ø
24x14
S-2 400
S-2 300
S-2 200
S-2 500
24x14
RR-1 1820
RR-1 1820
S-2 500
24x14
3
5DUCT SMOKEDETECTOR (TYP.)
VENTLESS DISHMACHINEHOOD SYSTEM
6
2
8
7
RTU 01
RTU 02
5
44
M1.0SCHEDULE
1
DESCRIPTION
CEILING DIFFUSER/SUPPLY REGISTER
EXHAUST AIR DUCT (RISE/DROP)
RETURN AIR DUCT (RISE/DROP)
SINGLE LINE DUCT BRANCH TAKE-OFF
DOOR UNDERCUT (3/4" MINIMUM)
FLEXIBLE DUCT (5'-0 MAXIMUM)
DUCT TRANSITION (RECTANGULAR TO ROUND)
DUCT LINING (1" THICK UNLESS OTHERWISE NOTED)
RECTANGULAR DUCT ELBOW WITH TURNING VANES
(ARROWHEAD REPRESENTS NUMBER OF THROW)
FURNISHED AND INSTALLED BY MECHANICAL
INSTALLED BY ELECTRICAL CONTRACTOR.FURNISHED BY MECHANICAL CONTRACTOR AND
FURNISHED AND INSTALLED BY ELECTRICAL
RR/RG RETURN REGISTER/GRILLE
CONTRACTOR.
DIAMETER
CONTRACTOR.
DOOR LOUVER
CONDENSATE DRAIN
DIA.
UC
DL
T-STAT
D
FLEX
EXHAUST REGISTER/GRILLE
FIRE DAMPER
MANUAL VOLUME DAMPER
FLEXIBLE CONNECTION
MVD
(L)
FD
FC
ER/EG
SUPPLY AIR (RISE/DROP)
CD/SR
RA/RET
EA/EXH
SA/SUP
SYMBOL & ABBREV.
T-STAT
PROGRAMMABLE THERMOSTAT
AFUE
TOTAL NET
STA
RTE
R
BY E.C.115/1Ø
ELECT.
MATERIAL
ALU
M.
PLA
STI
C
PRESSUREEASAOA RAITEM
875
--
-875---- --EF-1
ERTU-1
TOTAL
MANUFACT. MODEL NO. REMARKS
DUTY
SU
RFA
CE
SU
PP
LY
RE
TUR
N
EXH
AU
ST
CFM RANGE
LAY-
IN
MOUNTINGTYPED
IFFU
SE
R
RE
GIS
TER
GR
ILLE
ORNECKSIZE
CEILING GRID
DIFFUSER FACE
SIZE (INCHES)
(NO.) & AIRPATTERN
QU
AN
TITY
MARK
REMARKSAND
MODEL NO.D-D
R
ACCESSORIES
BIR
DS
CR
EE
N
X
V-B
ELT
AVTEC #180VX13D
BD
D
DIS
C
X
HPRPM
1/21325
SPCFM
1.25"875EF-1
MARK
MANUFACTURER
LBS
REMARKS
OP
ER
. WT.
MO
CP
MC
A
PH
AS
E
VOLT
S
FAN
HPCAPACITY
HEATING
MBH
OUTPUT
COMPRESSOR SECTION
MBHCAPACITYCOOLING
MIN
. EE
R
DRIVECFM ESPANDMANUFACTURER
MODEL NO.MARK
RTU-1
INPUT
1
STAGES
(WATTS)
FOR COMPLETE INFORMATION AND PRICING ON THE TRANE HVACPACKAGE CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNTEXECUTIVE AT TRANE NATIONAL ACCOUNTS.TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986-4822FAX: (502) 499-7870EMAIL: [email protected]
SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL INFORMAITON.
THERMOSTAT SENSOR (REMOTE)
XX-XXX
XX-XXXXX-XXX
AIR BALANCE SCHEDULE CFM 6
AIR DEVICE SCHEDULE 5
MECHANICAL SYMBOLS 9
SUPPLY AND EXHAUST FAN SCHEDULE 2
EXISTING HVAC UNIT SCHEDULE 4
T
TS
M
E
ME
DL
UC
Ø
D
BTU
H/W
ATT
S
230 1150 + 230
875950 4400 + 75
GENERAL NOTES:1. THE PIZZA OVEN HOOD IS ACTIVATED USING A TEMPERATURE RELAY, SET TO 90 DEGREES.2. PROVIDE OUTSIDE AIR THROUGH RTU IS SET AT 21%, UNLESS NOTED OTHERWISE.3. RESTROOM FAN IS ACTIVATED WITH LIGHT SWITCH IN RESTROOM, IS INTERMITTENT, ANDWILL HAVE NO EFFECT TO BUILDING RELATIVE PRESSURE.
LEVEL SUPPORT BY THE G.C. FABRICATED PLATFORM ON THE CONCRETE SLAB.CONDENSING UNITS TO COOLER/FREEZER MOUNTED ON FEILD
WATER HEATER DETAIL 8/P3.0.ROOF AND TERMINATE PER MANUFACTURER'S INSTRUCTION. REFER TOROUTE 3"PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE UP THRU
INSULATION FROM HOOD TO DUCT PENETRATION THRU ROOF. EF-1. INSULATE DUCT WITH 1" MINERAL WOOL EXTERNAL WRAP12"x12" WELDED EXHAUST DUCT FROM OVEN HOOD UP THRU ROOF TO
DO NOT ROUTE DUCTWORK OR PIPING OVER ELECTRICAL PANELS.6'-0" x 8'-0" OVEN HOOD. SEE M2.0.
YUM! APPROVED EMAX MODEL 50 THERMOSTAT MOUNTED ON WALL AT 48" A.F.F. NEAR MANAGER'S DESK. COORDINATE LOCATION WITH HEAT
1
2
3
4
5
7
8
6
MECHANICAL PLAN 1/4"=1'-0" 1
KEY NOTES 3
GASKET
TRANSITION TO ROUNDSEE PLANS FOR SIZE
BUTTERFLY DAMPER WITHARM & LOCKING QUADRANT(TYPICAL)
SHORT RADIUS RIGIDMETAL ELBOW WHERE1.5D FLEX ELBOWCANT BE MAINTAINED
1 1/2" DUCT WRAPINSULATION
FLEX DUCT SEESPECIFICATIONS FORMAX. ALLOWABLELENGTH (TYPICAL)
STRAP HANGER
LOW VELOCITYDUCT
NYLON STRAPFASTENER (TYP)
45° ENTRYCLINCHED COLLAR
1.5DMIN
SUPPLY
MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT RUNOUTS TOSUPPLY DIFFUSERS = 5'-0". FLEX DUCT IS NOT ALLOWEDON EXHAUST, RETURN, AND EXPOSED DUCTWORK.
DIFFUSER INSTALLATION DETAIL N.T.S. 7
GENERAL NOTES 8
SPECIFICATIONS.SHUTDOWN FOR RTU-1. REFER TO ELECTRICAL DRAWINGS ANDINSTALL SMOKE DUCT DETECTOR IN SUPPLY DUCTWORK AND UNIT
THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND SUPPORT OFROOFTOP EQUIPMENT WITH BUILDING STRUCTURE AND CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ROOFTOP UNITS TO ALLOW DUCT CONNECTION AND ROUTING AS SHOWN PER PLANS.
ANY FRESH AIR INTAKE SHALL BE SEPARATED FROM BUILDING EXHAUST, FLUES, OR PLUMBING VENTS AS REQUIRED BY LOCAL CODES.INSTALLATION OF APPROVED ROOFTOP UNITS OTHER THAN TRANE MAY REQUIRE MODIFICATIONS TO DUCTWORK LAYOUT. VERIFY ALL REQUIRED CLEARANCES FOR OTHER MANUFACTURERS.
THE CONTRACTOR SHALL VERIFY ALL STRUCTURAL CONDITIONS FORCEILING SPACE AND EXACT DUCT ROUTE PRIOR TO FABRICATION. VERIFY IN FIELD EXACT ROUTING OF DUCTWORK TO ALLOW PROPER LOCATION OF LIGHTS AS SHOWN.
1.
2.
3.
5.
4.
6.
THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS SHEETS FOR FURTHER INFORMATION.
--
--
XEGER ADVANTAGE
SQ. TO RD. TRANS.XX& 5(4W) 300-500X12x12 24x24 PRODUCTS
PLASTIC DIFFUSERSS-2 (1)2W, (5) 3W,NA120V14000.25"70EF-2 ACCUSERV #05247-017(100w) X XX
---- --EF-2 - ----- --
X2R-1 18x18 24x24(2)4WC
2000X X X
EGERPRODUCTS
PRODUCING EQUIPMENT. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL LINE VOLTAGE WIRING AND CONDUIT.
9
EGER ADVANTAGESQ. TO RD. TRANS.
XX PRODUCTSPLASTIC DIFFUSERS(1)2WC
75X12x126x61S-1
REMOTE TEMPERATURE / HUMIDITY SENSOR, AS LOCATED ON PLANS.
--NRTU-1 720 3650 + 730--
DUCT SMOKE DETECTOR
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
203
0 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
30
339
678
/ 336-8503
T
ELE
PH
ON
E
678/ 3
36-8
508 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
1, 2TRANE
.80"2300 BELT 11.2 71.95 1 208 31YHC 072RTU-2
INSTALL NEW FLEXIBLE CONNECTION AT UNIT.JOISTS. TRANSITION IN ROOF CURB TO NEW ROOF TOP UNIT ANDROUTE NEW SUPPLY AIR DUCT AND RETURN AIR DUCT UP BETWEEN
1, 2120,00TRANE
.80"2300 BELT 11.2 71.95 96,000 1 208 3 36.5 50 93580%1YHC 072
120,00 96,000 80% 36.5 50 935
NOTES:
1. PROVIDE WITH ENTHALPY CONTROLLED ECONOMIZER WITH BAROMETRIC RELIEF.2. PROVIDE WITH UN-POWERED CONVENIENCE OUTLET AND DISCONNECT.3. PROVIDE WITH RETURN AIR DUCT MOUNTED DUCT SMOKE DETECTOR.
DUCT THIMBLE FABRICATION ANDINSTALLATION REQUIRED BYINSTALLING CONTRACTOR
DUCT THIMBLE
avtec
1N
1N
1N
1N
1N
1N1N
M2.0DRAWINGS
CHINOOK/TAKU-3 (15) BUSINESS DAY LEAD TIME
CHINOOK/TAKU-4 (18) BUSINESS DAY LEAD TIME
ECO ARCH-3 (15) BUSINESS DAY LEAD TIME
ECO ARCH-4 (18) BUSINESS DAY LEAD TIME
CONVEYOR-5 QUOTED LEAD TIME
UDS-5 QUOTED LEAD TIME
LEAD TIME FROM SIGNEDAPPROVED DRAWINGS
& VALIDATED PO
unified brands
randellavtecgroen
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
EL
OP
ME
NT
2030 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 2
04
AT
LA
NT
A, G
EO
RG
IA
30339
67
8/ 336
-850
3 T
ELE
PH
ON
E
678/ 336-8508 F
AC
SIM
IL
E
OS
WE
LL
+
N
IT
IS
HIN
P1.0
PLUMBINGSCHEDULE AND
NOTES
ABBREVIATIONS
PRESS-TEMPERATURE RELIEF VALVE
PREMIXED TEMPERATURE WATER
FLOOR CLEANOUT OR CLEANOUT TO GRADE
C.D.
F.C.O.
FW
W.C.O.
S.O.V.
H.B.
C.V.
S.O.C.
P.T.R.V.
B.V.
TWTW
FW
CD
CHECK VALVE
BALL VALVE
SHUT-OFF GATE VALVE
SHUT-OFF GAS COCK
FILTERED WATER
WALL CLEANOUT
CONDENSATE DRAIN
HOSE BIBB
ABBREV
S OR W
CW
H.W.R.
HW
S.D.
SYMBOLS
SD
V.
G G
DESCRIPTION
SOIL OR WASTE
COLD WATER
STORM DRAIN
SANITARY VENT
HOT WATER RETURN
HOT WATER
GAS
COLD WATER BELOW GRADE
FILTERED TEMPERED WATER
FLOOR DRAIN
FLOOR SINK
HUB DRAIN
F.S.
F.D.
H.D.
FTW FTW
C.W.
ABOVE FINISHED FLOOR
EXTERIOR CLEAN OUT
CAST IRON
OVERFLOW DRAIN
EXISTING
GAS LINE
NEW
YARD BOX
ROOF DRAIN
VENT THRU ROOF
ACCESS PANEL
VENT BELOW FLOOR
UP THRU ROOF
A.F.F.
E.C.O.
C.I.
G.L.
OFD
(E)
(N)
A.P.
V.B.F.
U.T.R.
V.T.R.
R.D.
Y.B.
S.O.V. SHUT-OFF IN DROP
YARD HYDRANTY.H.
B.F.P. BACKFLOW PREVENTER ASSEMBLY
GREASE WASTEGWGW
UNION
SS
CONDENSATE DRAIN WITH 120V HEAT TAPECD C.D.
TEMPERING MIXING VALVE
CW
HW
HWR
PLUMBING SCHEDULE A
PLUMBING LEGEND B
SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.
ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED INPLACE.
CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISETHE SEWER SYSTEM AS REQUIRED.
PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODE. PROVIDE DEEPSEAL TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.
ALL CLEANOUTS SHALL BE INSTALLED SO THAT THEY ARE READILY ACCESSIBLE. THE CONTRACTOR SHALLCOORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION.
ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS AND OTHER EQUIPMENT SHOWN IN WALLS ORABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACEAND 10 FEET FROM ANY OUTSIDE AIR INTAKE.
CONTRACTOR SHALL PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED.
PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OFEQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODEAND RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECEOF EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THEGAS METER.
ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.
REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORKTO BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TOKITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR.
REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS.
ALL GAS LINES SHALL BE SUPPORTED.
ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.
PROVIDE WATER HAMMER ARRESTORS FOR ALL WATER LINES.
PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THEDIAMETER OF THE INDIRECT DRAIN.
PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION ANDCONDITION OF ALL EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATEDWHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.
CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TOAVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.
CONTRACTOR SHALL FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIESHAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0"A.F.F.
CONTRACTOR SHALL PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TOUNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITHTHE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.
IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THESTART OF ANY WORK, AND NOTIFY THE OWNER IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICETHE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND & SHALL NOT REQUIRE TIGHTGRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BEMOUNTED NO MORE THAN 44" ABOVE THE FLOOR, THE FORCE REQUIRED TO ACTIVATE CONTROLSSHALL BE NO GREATER THAN 5 POUNDS.
A CLEAR FLOOR SPACE 30" WIDE BY 48" LONG SHALL BE PROVIDED IN FRONT OF THE LAVATORY TOALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE & TOE SPACE UNDERNEATH THE LAVATORY.
HOT WATER & DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACE UNDER LAVATORIES.
FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND & SHALLNOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TOACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS/FT LEVER PUSH-TYPE &ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN, SELFCLOSING VALVES ARE ALLOWED IF THE FAUCETS REMAIN OPEN FOR AT LEAST 10 SECONDS.
FLUSH HANDLES SHALL BE ON THE WIDE SIDE OF STALLS IN DISABLED ACCESSIBLE STALLS.
MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE NOT MORE THAN 40" FROM THE FLOOR.
LOCATE HAND DRYER OPERABLE PARTS NOT MORE THAN 40" FROM THE FLOOR.
LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12" OF THE FRONT EDGE OF THE TOILETSEAT.
ACCESSIBILITY NOTES D
GENERAL NOTES C
FS 1 FLOOR SINK 4" 2" -- -- -- 6 --PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP FLUSH WITH FLOOR TILE.
JOSAM / MODEL: JPFS4-PVC
JONESPEC / MODEL: FD-2370-PV4-DS-F
FD 1 FLOOR DRAIN(3")
3" 2" -- -- -- 2 --PVC FLOOR DRAIN, 5" DIA.IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USEDFOR THE FIRST 10'-0" FROM THE DRAIN
ZURN / MODEL: FD-2210
JOSAM / MODEL: 30003-A
WADE / MODEL: 1103
ECO 1EXTERIORCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WC 1WATERCLOSET 4" 2" 1/2" -- -- 4 2 CRANE "ECONMISER" / MODEL: 3H839
SA 1SHOCKARRESTOR -- -- 1/2" -- -- -- --
STAINLESS STEEL CASING WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN.SIZED PER PDI-WH201
WADE / SHOKSTOP
JOSAM / MODEL: 75000
ZURN / SHOKTROL
MV 1MIXINGVALVE -- -- 1/2" 1/2" -- -- --
THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,CHECK VALVES SIZE PER PIPE CONNECTIONS.
HYDROTEK SERIES HBL
LAWLER SERIES 61
LEONARD SERIES 210
S 33-COMP.SINK INDIRECT -- 1/2" 1/2" -- -- 3
STAINLESS STEEL 3 COMPARTMENT SINK, FAUCET & DRAINFURNISHED BY OWNER, INSTALLED BY CONTRACTOR.
AERO # 3F3-DC-YUM-RH48
--
--
S 1 HAND SINK 1-1/2" 1-1/2" -- -- 1/2" 2 1.5STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS.FAUCET W/KNEE PEDAL VALVE. OWNER FURNISHED AND CONTRACTOR INSTALLED. CONTRACTOR TO PROVIDE STAINLESS STEEL SPLASH GUARDS, AS REQUIRED.
AERO # HSK
ALL STRONG, MODEL #HS-1516KSS
SANILAV, MODEL #CLS-505
HD 1 HUB DRAIN 3" 2" -- -- -- 2 --CAST IRON DEEP SEAL P-TRAP WITH FUNNEL, NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG.
JOSAM / MODEL: 88213
WADE / MODEL: 2453EF
ZURN / MODEL: Z-1019
WCO 1WALLCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS PLUG, WITH STAINLESS STEEL ACCESS COVER.
JOSAM / MODEL: 58510
WADE / MODEL: 8560E
ZURN / MODEL: Z-1446-BP
FCO 1FLOORCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WH 1WATERHEATER -- -- 3/4" 3/4" -- -- --
GAS FIRED WATER HEATER, 84% THERMAL EFF., 199,000 BTUH INPUT, INSTANTANEOUS TYPEHEATER, 9.8 GPM @ 35°F RISE, UBBINK CONCENTRIC FLUE/AIR INTAKE SYSTEM (WALL-TYPE),DIRECT ELECTRONIC IGNITION SYSTEM, REMOTE ELETRONIC CONTROLS AND INTEGRALDIAGNOSTICS. SEE NATIONAL PRICING CONTACT BELOW.
RINNAI / RC98HPi (KA3237FFUD)
--
--
VENTSOIL ORWASTE
FIXTUREITEM
WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,ELONGATED BOWL, ADA COMPLIANT, 1.6 GPF, WITH OPEN FRONT SEAT LESS COVER,OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLLUSHMATE OR EQUAL.PROVIDE TANK COVER LOCKS. FLUSH VALVES SHALL BE RIGHT HAND OR LEFT HAND ASREQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDEREQUIREMENTS
WATERFU
WASTEFU
TEMP'DWATER
HOTWATER
COLDWATER
DESCRIPTION MANUFACTURER / MODEL NUMBER
L 1 LAVATORY 1-1/2" 1-1/2" -- -- 1/2" 1 1.5WHITE VITREOUS CHINA, WALL HUNG, WITH WALL HANGAR SUPPORT, 4" CENTERS,WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHEDBY OWNER-INSTALLED BY G.C. SINGLE LEVER TYPE FAUCET, ADA COMPLIANT.CONTRACTOR TO PROVIDE PROPER WALL MOUNTING SUPPORT.
A.S. COMRADE/ MODEL: 0124.024
CRANE "HARWICH" / MODEL: 1412V
S 2 MOP SINK 3" 2" 1/2" 1/2" -- 3 2.25MOP SINK: 24"L X 24" W X 10" H. FIBERGLASS.OWNER FURNISHED AND CONTRACTOR INSTALLED.FAUCET: T & S #B-0674-BSTP, WITH VACUUM BREAKER, FURNISHED BY OWNER-INSTALLED BY G.C.
E. L. MUSTEE & SONS, MODEL # 63M
--
--
GI 1GREASEINTERCEPTOR 4" 3" -- -- -- -- --
GREASE INTERCEPTOR IS EXIISTING PROVIDED B LANDLORD 1,000 G.P.M. EXTERIOR CONCRETE UNIT TO MEET LOCAL REQUIREMENTS..
SCHIER / TRAPPER II #PATG-3050
--
--
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
WATER HEATER NATIOINAL ACCOUNT PROCESS:RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:
RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:
1) CNA contacts Rinnai Inside Sales at 1.866.383.0707.
2) Rinnai will provide CNA with distributor contact in the project market to facilitate ordering.
3) CNA, General Contractor or installer will contact distributor and purchase product.
1) CNA contacts Rinnai at 1.866.383.0707 and follows prompts to Service.
2) Rinnai will provide CNA with Authorized Service Providers (ASP) in the arae of the facility.
3) CNA will contact the ASP to maintain or service the product.
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
203
0 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
30
339
678/ 336-8503 T
ELE
PH
ON
E
678/ 33
6-85
08 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
T
MV 1
3/4" HW
1/2" HW
3/4" CW
1" CW
3/4" CW1" HW
WATER SERVICESUBMETER
EXISTING WATER SERVICE ABOVECEILING. VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS
NEW GAS SERVICE ON ROOF, FROMNEW GAS METER AND REGULATOR.VERIFY LOCATION AND CONNECTIONREQUIREMENTS, PROVIDE WITH ROOF
NEW GAS SERVICE ON ROOF,ROUTE DOWN TO CEILING SPACE.
PIPE SUPPORTS.
NEW GAS SERVICE ON ROOF,ROUTE TO ROOFTOP A/C UNITS
1/2" CW
T
FS 2S 2
WH 1 2
S 3
9 10 9
S 16
9
3
HD 1
1 7 12
GI 1
L 1
WC 1
FD 1 FD 1
11 9 9
9
8
EXISTING SANITARY WASTE SERVICE BELOWGRADE. VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS
5
5 54
P2.0
PLUMBINGPLANS
PLUMBING WASTE AND VENT PLAN 1/4"=1'-0" A
PLUMBING WATER AND GAS PLAN 1/4"=1'-0" C
ROUTE EVAPORATOR COIL CONDENSATE DRAIN WITH PROPER SLOPE TO HUB DRAIN1
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
203
0 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
30
339
678/ 336-8503 T
ELE
PH
ON
E
678/ 33
6-85
08 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
KEY NOTES B
KEY NOTES D
10
VERIFY METER LOCATION AND CAPACITY WITH LOCAL GAS
LEG, UNION, AND VALVE AT UNIT.
HEATER. PIPE RELIEF TO MOP SINK.
2" GAS DOWN TO OVENS, SEE OVEN GAS PIPING DETAIL 3/P3.0.
1" HOT AND COLD WATER, 1-1/4" GAS DOWN TO GAS WATER
GAS LINE UP THRU ROOF TO ROOFTOP UNIT. INSTALL DRIP
COMPANY. ROUTE NEW 2" LINE TO SPACE AS REQUIRED.
9
8
7
6
5
4
3
2
1
DO NOT ROUTE ANY PIPING OVER ELECTRICAL PANELS.
WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISH CEILING. UNDER
ALL DETAILS.
3/4" HOT AND COLD WATER DOWN IN WALL TO 3-COMPARTMENT SINK. INSTALL WATTS NO. 9N BACKFLOW PREVENTER FOR EACH WATER LINE CONNECTION TO FAUCET. INSTALL EXACTA SANITIZER DISPENSING
PROVIDE 3/4" HOT WATER TO DISHWASHER/BOOSTER HEATER.CONTRACTOR SHALL PROVIDE AND INSTALL WATER HAMMER ARRESTOR(PDI SIZE A, ASSE 1010) AND 25 PSI PRESSURE REGULATING VALVEWITH INTERNAL THERMAL EXPANSION BY-PASS ON SUPPLY LINE. CONTRACTOR SHALL INSTALL VACUUM BREAKER AND ALL ACCESSORIESPROVIDED WITH DISHWASHER PER MANUFACTURER'S REQUIREMENTS.
THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FORROUTING AND CONNECTION OF WATER AND GAS SERVICE.
CONNECT NEW 1" COLD WATER LINE TO EXISTING WATER SERVICELINE ABOVE CEILING. FIELD VERIFY EXACT LOCATION ANDCONNECTION REQUIREMENTS.
ROUTE HOT AND COLD WATER ABOVE CEILING, BELOW BUILDING INSULATION.
MACHINE OUTLET AND SHUT-OFF VALVE AT 12" A.F.F.PROVIDE T&S "SAFE-T-LINK" CW-4B-60, 3/8", 5 FT. COILED STAINLESSSTEEL BRAIDED HOSE WITH EXTRUDED COATING - T&S AW-5B-SS 3/8" STAINLESS STEEL QUICK DISCONNECT TO CONNECT TO HOT HOLDCABINET WATER CONNECTION PER MANUFACTURER'S INSTRUCTIONS.
12
KNEE PEDAL CONTROL. 1/2" COLD AND TEMPERED WATER DOWN IN WALL TO HAND SINK WITH
TEMPERING MIXING VALVE ABOVE CEILING. REFER TO DETAIL 9/P3.0.
11
SLAB DISTIBUTION ALLOWED AT CONTRACTOR OPTION. COORDINATE
VENDOR INSTALLS EXACTA SYSTEM AT MOP SINK, PR DETAIL 2/P3.0.13
SYSTEM PER DETAIL 10/P3.0.
14
15
THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR ROUTINGAND CONNECTION OF WASTE LINES. ALL FIXTURE DRAINS AND TRAPS TOBE VENTED AS PER LOCAL CODE.
WITH 1/2" FOAM RUBBER PER SPECIFICATIONS. SEE DETAIL 5/P3.0.ELECTRICAL HEAT TAPE ON DRAIN LINE IN FREEZER. INSULATE DRAIN LINESMINIMUM OF 74" A.F.F. TO AVOID CONFLICT WITH SHELVING. PROVIDECLOSE TO FREEZER/COOLER CEILING AS POSSIBLE. DRAIN LINE SHALL BE AAND PROVIDE PROPER AIR GAP. CONDENSATE DRAIN LINES SHALL BE ROUTED ASROUTE EVAPORATOR COIL CONDENSATE DRAIN WITH PROPER SLOPE TO HUB DRAIN
VERIFY EXACT LOCATION AND CONNECTION REQUIREMENTS.CONNECT NEW WASTE TO EXISTING WASTE BELOW FLOOR AS REQUIRED.
FLOOR DRAIN SHALL BE INSTALLED FLUSH WITH FINISHED FLOOR.DO NOT SLOPE FLOOR TO DRAIN.
DETAIL 6/P3.0.CONDENSATE DRAIN LINE UP TO ROOFTOP UNIT. REFER TO
PROVIDE INDIRECT WASTE CONNECTION FROM 3-COMPARTMENT SINK
1-1/4" CONDENSATE DRAIN DOWN IN WALL AND TERMINATE ABOVE MOPSINK WITH PROPER AIR GAP.
PROVIDE INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK WITH PROPERAIR GAP.
TO FLOOR SINK WITH PROPER AIR GAP.
PROVIDE FLOOR SINK IN LIEU OF HUB DRAIN WHERE REQUIRED BY LOCALCODES.
ROUTE DRAIN LINE FROM BOOSTER HEATER TO FLOOR SINK WITH PROPERAIR GAP.
13
12
11
8
7
10
6
5
4
3
2
1
SCHEDULE 40 PVC DWV OR AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.AND OUTLET OF INTERCETOR TO CONNECTION AT SANITARY MAIN SHALL BE ENTIRE RUN OF DRAIN LINES TO INLET OF GREASE INTERCEPTOR
PROVIDE TRAP PRIMER TO HUB/FLOOR DRAIN/SINK. REFER TODETAIL 1/P3.0.
9
PROVIDE 1/2" CW CONNECTION TO DISH MACHINE VENTLESS HOOD AS REQUIRED BY MANUFACTURER.
16
FOR PROPER DRAINAGE FROM HOOD PER MANUFACTURER'S REQUIREMENTS.VERIFY DRAIN CONNECTION FROM VENTLESS HOOD TO DISHMACHINE
1/2" COLD WATER LINE DOWN IN WALL, PROVIDE RECESSED WASHING
P3.0
PLUMBINGDETAILS &
GAS ISOMETRIC N.T.S. 11
TEMPERING VALVE DETAIL N.T.S. 9
3-COMP SINK EXACTA SYSTEM DETAIL N.T.S. 10
WASTE ISOMETRIC N.T.S. 12
COOLER/FREEZER PIPING N.T.S. 5 TRAP PRIMER DETAIL N.T.S. 1
RTU COND. DRAIN DETAIL N.T.S. 6 MOP SINK DETAIL N.T.S. 2
OVEN GAS PIPING DETAIL N.T.S. 3
NOT USED N.T.S. 4
WH 1
CLEANING SOLUTIONDISPENSER BAGS, (SANITIZER)PROVIDE BY ECOLAB.
WASH RINSE SANITIZE
PROVIDE ANTI-SIPHON DEVICE ORBACKFLOW PREVENTER AS REQUIREDBY ATHORITY HAVING JURISDICTION.
PROVIDE ANTI-SIPHONDEVICE OR BACKFLOWPREVENTER AS REQUIREDBY ATHORITY HAVINGJURISDICTION.
COLD WATER SUPPLY
GAS SUPPLY
Rinnai
Water Heater
HOT WATERTO OUTLETS
Rinnai
Water Heater
PRIMARY Sub
WATER HEATER DETAIL N.T.S. 7
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
20
30
P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
303
39
678/ 336-8503 T
ELE
PH
ON
E
67
8/ 336
-85
08 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
FS 2
S 2
FCO 1
HD 1 9
WC 1
FD 1
S 1
GI 1
FCO 1
FD 1
LAV 1
S 1
FD 1
FLOOR SINK AS
LOCATED ON PLANS.
GREASE INTERCEPTOR WITH
BUILT-IN FLOW CONTROL.
GREASE INTERCEPTOR IS RATED AND MANUFACTURED WITH AN
INTERNAL FLOW CONTROL SYSTEM ALREADY IN PLACE. THEY
DO NOT REQUIRE AN EXTERNAL FLOW CONTROL FITTING.
DISHWASHER
LOCATION
UNDER SLAB PIPING
FROM ADJACENT
DRAINS.
5.
4.
15.
14.
12.
13.
11.
10.
3.
2.
1.
7.
9.
6.
8.
16.
17.
18.
ELECTRICAL CONTRACTOR SHALL PROVIDE DUCT DETECTORS IN QUANTITYAS SHOWN ON THE PLANS FOR ALL AIR-MOVING SYSTEMS PRODUCING 2000CFM OR GREATER. DUCT DETECTOR SHALL BE INSTALLED IN THE SUPPLYDUCT OF THE INDICATED UNIT. DUCT DETECTOR SHALL BE "SIMPLEX TRUEALARM" #4098-9687 OR EQUAL WITH #4098-9842 CONTROL STATION PERDUCT DETECTOR SHOWN. THE DUCT DETECTOR AND THE CONTROL STATIONSHALL BE WIRED AS DESCRIBED IN THE MANUFACTURER'S LITERATURE.ALARM LIGHT AND PIEZO SHALL OPERATE IN ALARM CONDITION. THE'POWER' LIGHT SHALL OPERATE AT ALL TIMES AND EXTINGUISHING OFTHIS LIGHT SHALL INDICATE TROUBLE OR FAULT WITH THE SYSTEM. APLACARD SHALL BE INSTALLED ABOVE THE CONTROL STATION MODULE THATREADS "DUCT DETECTOR TROUBLE IF GREEN LIGHT IS NOT ON, CALL FORSERVICE". THIS SYSTEM SHALL BE INSTALLED TO COMPLY WITH NFPA 90A4-4 REQUIREMENTS. VERIFY NFPA 90A 4-4 CODE REQUIREMENTS PRIOR TOINSTALLATION.
19.
SMOKE MONITORING SYSTEM 7
ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONALELECTRIC CODE (NEC), THE AMERICANS WITH DISABILITIES ACT (ADA), AND ALL STATEAND LOCAL REQUIREMENTS AND CODES.
REFER TO RELATED ARCHITECTURAL, MECHANICAL, AND STRUCTURAL DRAWINGS FORRELATED INFORMATION.
THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THEEQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALLVERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILUREOF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITYFOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
SEPARATE GREEN GROUND CONDUCTOR SHALL BE ROUTED IN ALL CONDUITS WITH ALLPHASE CONDUCTORS.
ISOLATED GROUND FOR P.O.S. SYSTEM SHALL BE CONTINUOUS FROM LAST OUTLET TOPANEL. DEDICATED CIRCUIT WITH SEPARATE ISOLATED GROUND WITH LESS THAN 0.5OHM IMPEDANCE. TERMINATE AT NEUTRAL TO GROUND BUS BAR INSIDE THE MAINSOURCE PANEL.
ALL MECHANICAL EQUIPMENT SHALL BE COMPLETELY CONNECTED BY ELECTRICALCONTRACTOR INCLUDING BOTH POWER AND CONTROL WIRING. ELECTRICALCONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THEREQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING ANDCONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS.
BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS FOR CLARITY ONLY,ELECTRICAL CONTRACTOR MAY GROUP SINGLE POLE BRANCH CIRCUITS IN MULTIPLECIRCUIT HOME RUNS. (3 CIRCUITS MAX @ 120/208V 3Ø, 2 CIRCUITS MAX @ 120/240V. 3Ø &1Ø). A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER,RECEPTACLE, AND LIGHTING CONDUITS.
ALL EXTERIOR CONDUIT FOR ROOF MOUNTED EQUIPMENT AND WIRING SHALL BEMINIMIZED BY ROUTING IN CEILING SPACE. NO EXTERIOR CONDUIT WILL BE ACCEPTED.
ALL CONDUITS SHALL BE CONCEALED IN WALL SPACE, CEILING SPACE OR UNDER FLOOR,NO EXPOSED CONDUIT PERMITTED.
ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL CONDUIT FOR LOW VOLTAGEWIRING. LABEL CONDUIT TO IDENTIFY ITS INTENDED USE (I.E.: CONTROL, SECURITYSYSTEM, PHONE, DATA, ETC.).
WHEN ALUMINUM CONDUCTORS ARE PRESENT, E.C. SHALL VERIFY ALL CONNECTIONSAND REPLACE AS REQUIRED
COMPLETE SYSTEM SHALL BE GROUNDED PER N.E.C. ARTICLE 250..
FINAL CONNECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITHU.L. APPROVED LIQUID TIGHT CONDUIT. PROVIDE WITH GROUND WIRE SIZED PER N.E.C.ART. 250 (1999).
WIRE CONNECTION FROM JUNCTION BOX TO LAY-IN LIGHT FIXTURES MAY BE ENCASED INFLEXIBLE CONDUIT 6'-0" MAXIMUM
BUILDING SIGNAGE CONNECTIONS INDICATED ON LIGHTING PLAN.
ALL EXISTING ELECTRICAL FIXTURES, DEVICES AND CIRCUITING NOT RELOCATED ORREUSED SHALL BE REMOVED BACK TO POINT OF SUPPLY.
E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING TO COMPLY WITHN.F.P.A. 96.7-3.1.3 FOR POWER SHUTOFF ON ALL ELECTRICAL EQUIPMENT UNDER OVENHOOD. VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHINGSYSTEM SUPPLIER. PROVIDE ONLY IF REQUIREDBY LOCAL CODE.
WESTERN REGION STANDARD MAIN PANEL RATING IS 42KAIC. WHEN GE MAIN PANEL ISUSED IN WESTERN REGION - RATING SHALL BE 65KAIC.
EASTERN REGION MAIN PANEL SHALL BE 22KAIC.
SMOKE DETECTOR WIRING 6
ALARM CONTACTS
JUMPER
RTU TERMINAL STRIP(LTB1)
SMOKE DETECTORS LOCATEDIN SUPPLY AND RETURN AIRDUCTS. INCLUDE IN SUPPLYDUCTS ONLY WHEREREQUIRED BY LOCAL CODE.WIRE TO SHUTDOWN AC UNITUPON DETECTION OF SMOKE.
24 VAC
REMOVEJUMPER1
HOOD WIRING DIAGRAM 8
POWER OUTTOSTARTER/CONTACTOR,ECT.
LIGHTMASTER LS2 DARKSENSOR PHOTOCELL
A-14
A-28
A-18
EXTERIOR SIGNAGE
SPACE
SHOW WINDOW RECEPTS
SWITCH LOCATED ATFRONT OF HOUSE
LIGHTING CONTROL DIAGRAM 4
A-19
A-20
INTERIOR LIGHTS
COOLER/FREEZER LIGHTS
INTERIOR LIGHTS
HVAC THERMOSTATA-14
A-24
LIGHTING CONTROL SEQUENCE OF OPERATION:
PRIOR TO OPENING FOR BUSINESS , CONTROL SWITCH FRONT OF HOUSE ISACTIVATED, INITIATING THE "OCCUPIED" MODE , SINGLE POLE SWITCH SHALL ENERGIZEBOTH CONTACTORS 'C1' AND 'C2'.
CONTACTOR 'C2' IS TO PROVIDE 'ON-OFF' CONTROL TO THE KITCHEN LIGHTS, FRONTLIGHTS, COOLER/FREEZER LIGHTS AND HVAC THERMOSTAT.
CONTACTOR 'C1' SHALL BE ENERGIZED TO PROVIDE CONTROL TO THE EXTERIORSIGNAGE AND THE SHOW WINDOW RECEPTACLES. THIS CONTACTOR IS CONTROLLEDTHROUGH THE PHOTOCELL NOTED. THIS PHOTOCELL IS TO TURN ON THE LIGHTS ATDUSK, SWITCH IS TO BE USED TO TURN OFF THE LIGHTS AT CLOSING.
'C2''C1'
FRANCHISE SUPPLY OF ELECTRICAL SWITCHGEAREQUIPMENT IS FROM ACCUSERV.
THE ACCUSERV SWITCHGEAR IS TO BE PURCHASEDTHROUGH APPROVED YUM SYSTEM DISTRIBUTION.THE GENERAL CONTRACTOR IS RESPONSIBLE FORINSTALLATION OF THE SYSTEMS DESCRIBED IN THEPLANS. FRANCHISEES SHOULD CONTACT THEIRAPPROVED YUM SYSTEM DISTRIBUTOR FOR A PRICEQUOTE AND A BILL OF MATERIAL CONFIRMATION FORTHEIR SPECIFIC PROJECT. SEE THE SWITCHGEARSECTION IN THE SCOPE OF WORK FOR ADDITIONALINFORMATION.
PRIMARY CONTACT: BUDDY BOCKWEGPHONE: (877) 707-7378FAX: (502) 961-0357EMAIL: [email protected]
THE ACCUSERV SWITCHGEAR PACKAGE CONSISTS
OF SERVICE ENTRANCE, SWITCHGEAR, MAIN
PANELS, SUB PANELS, LIGHTING CONTACTORS AND
ALL ASSOCIATED PRODUCTS TO COMPLIMENT THE
SWITCHGEAR PACKAGE.
BE PREPARED AT TIME OF ORDER OR QUOTE REQUESTTO PROVIDE ALL PROJECT DETAILS REGARDINGSPECIFICATIONS AND QUANTITIES AS SITE SPECIFICDESIGN MAY NOT MATCH PROTOTYPICAL DESIGN.
CORPORATE NATIONAL ACCOUNT AGREEMENT IS WITHGEXPRO (formally GE Supply) FOR THE SUPPLY ANDDISTRIBUTION OF ELECTRICAL SWITCHGEAR EQUIPMENTFOR COMPANY DEVELOPMENT ONLY .
UNDER THIS AGREEMENT, THE CONTRACTOR ISRESPONSIBLE FOR PURCHASE AND INSTALLATION OFTHE SYSTEMS DESCRIBED IN THE PLANS. ALL COMPANYPROJECTS MUST CALL GEXPRO's NATIONAL ACCOUNTDEPARTMENT FOR A PRICE QUOTE AND A BILL OFMATERIAL CONFIRMATION FOR THEIR SPECIFIC PROJECT.SEE THE SWITCHGEAR SECTION IN THE SCOPE OF WORKFOR ADDITIONAL INFORMATION.
PRIMARY CONTACT: MIKE URKOSKIPHONE: (630) 718-6529FAX: (630) 718-6567EMAIL: [email protected]
THE GEXPRO SWITCHGEAR PACKAGE CONSISTS OF
SERVICE ENTRANCE, SWITCHGEAR, MAIN PANELS,
SUB PANELS, AND LIGHTING CONTACTORS. GEXPRO
IS ALSO ABLE TO SUPPLY A FULL LINE OF GEXPRO
AND NON-GEXPRO PRODUCTS TO COMPLIMENT THE
SWITCHGEAR PACKAGE.
BE PREPARED AT TIME OF ORDER OR QUOTE REQUESTTO PROVIDE ALL PROJECT DETAILS REGARDINGSPECIFICATIONS AND QUANTITIES AS SITE SPECIFICDESIGN MAY NOT MATCH PROTOTYPICAL DESIGN.
CORPORATE DEVELOPMENT
NATIONAL ACCOUNTS: SWITCHGEARINSTALL STANDARD PACKAGE. SUPPLY and INSTALL NON-STANDARD COMPONENTS.
FRANCHISE DEVELOPMENT
EXTERIOR WALL INTERIOR
4 #500 KCMIL IN 4" C.
4 #500 KCMIL & 1 #3 GRD. IN 4"C.
METER AND C.T. CABINETPER UTILITY COMPANYSTANDARDS.
400A., 3P., 240V., DISC. SW. FUSEDAT 400A. NEMA-3R, S.E. RATED.
1 #6 - 3/4" C. TO 3/4" DIA. X 10'-0"LONG COPPERCLAD GROUND ROD WITH"CADWELD" CONNECTION.
1 #1/0 - 3/4" C. TO WATER SERVICEWHERE SERVICE ENTERS BLDG. ANDOTHER GROUNDING ITEMS SPECIFIEDIN N.E.C. ARTICLE 250-50.
4 #500 KCMIL IN 4" C.(400A. SERVICE)
4 #500 KCMIL, 1 #3 GRD. & 1 #3 ISO. GRD. - 4"C.
PROVIDE PANEL 'A' WITH DOUBLE LUGS.
VERIFY EXISTING SERVICE ENTRANCECONDUCTORS FOR NEW LOAD. PROVIDEPIZZA HUT CONSTRUCTION PROJECTMANAGER WITH WRITTEN VERIFICATION.
GROUNDING NOTE: VERIFY EXISTING SYSTEM ISGROUNDED PER N.E.C. ART. 250. UPGRADE ASREQUIRED. CONNECT NEW SYSTEM TO EXISTINGGROUND.
ELECTRICAL DISTRIBUTION EQUIPMENT SHOWN IN LIGHT PEN IS EXISTING.
ELECTRICAL RISER DIAGRAM NOTES:
1.
NOTE: INFORMATION ON PLANS REGARDING ELECTRICAL DISTRIBUTION EQUIPMENT WAS
BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. E.C. SHALL VERIFY
EXISTING CONDITIONS. NOTIFY PIZZA HUT CONSTRUCTION PROJECT MANAGER IMMEDIATELY
OF ANY DISCREPANCY AFFECTING THE INTENT OF THE DESIGN CONVEYED HEREIN.
PROVIDE #1/0 CU. - 3/4" C. TOBOND GAS, WATER AND SPRINKLERPIPING PER N.E.C. ARTICLE 250-104
400A., 120/208V., 3Ø, 4W. ELECTRICAL SERVICE.2.
NEUTRAL BUS AND GROUND LUG IFREMOVE MAIN BONDING JUMPER BETWEEN
EXISTING SERVICE EQUIPMENT NEUTRALIS ALREADY BONDED PER N.E.C.
'B'
PANEL
'A'
PANEL GC SHALL VERIFY WITH LOCALAUTHORITY HAVING JURISDICTION IFELECTRICAL DISCONNECT IS REQUIRED.
FROM POLE MOUNTEDTRANSFORMER
NEW OVERHEAD SERVICE
(SEE SITE PLAN E5.0)
SPACE
E1.0
SCHEDULES, NOTES AND
ELECTRCALDELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
2030 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
3033
9
678/ 3
36-8
503 T
ELE
PH
ON
E
678
/ 336
-850
8 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
TT
B:9
18"
13
18"
B:15
A:17
A:7
A:25
WP/GFIA:23
A:11 A:3
18" 18"
A:37 A:31
18"
B:1
3 #6, #10 GRD., 1" C.
8
A:27
18"
A:5
18"
A:12
9
B:2
A:8
18"11
11
A:9
18"
12
CE
-1
5
CC-1
B-14/16/18
FC-1
4
FE-1
A-38/40/42 A-29
EF-1A-29
7
13A:25
A:27
B:8
10
A:15
17
166
18
A:15
RTU 01
RTU 02
EQ EQ
E2.0
ELECTRICALPOWER PLAN
1
2
3
ALL CONNECTIONS AND ELECTRICAL EQUIPMENT LISTED IN SCHEDULE SHALL BEPROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. FIELD VERIFYCONNECTION REQUIREMENTS AND EQUIPMENT PROVIDED BY OTHERS PRIOR TOROUGH-IN.
REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTSASSOCIATED WITH WIRING AND CONNECTIONS OF INTERLOCKING, THERMOSTATLOCATIONS, EXHAUST FAN CONTROL SWITCHES, AND OTHER CONTROLS OFMECHANICAL EQUIPMENT.
PROVIDE DUCT MOUNTED SMOKE DETECTORS IN THE SUPPLY DUCT. VERIFY THEREQUIRED QUANTITY OF DUCT SMOKE DETECTORS FOR EACH UNIT WITH DUCTWORKLAYOUT TO MEET NFPA REQUIREMENTS. REFER TO SMOKE MONITORING SYSTEMNOTES ON SHEET E1.0.
ELECTRICAL POWER PLAN 1/4"=1'-0" 1
KEYED NOTES 24MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES 5
15
14
13
12
11
10
9
8
7
6
1
2
3
4
5
3
A. HORIZONTAL DIMENSIONS TO J-BOXES ARE FROM FACE OF STUD CENTER OF BOX, U.O.N.VERTICAL DIMENSION OF 18" IS FROM FINISH FLOOR TO CENTER OF J-BOX, U.O.N.
B. PROVIDE BLACK OUTLETS, SWITCHES AND COVER PLATES IN F.O.H.
C. ALL OUTLETS AND J-BOXES BEHIND SIGNAGE SHALL BE RECESSED OR FLUSH WITH ADJACENT BUILDING SURFACES.
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
ELO
PM
EN
T
203
0 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 204
AT
LA
NT
A, G
EO
RG
IA
30
339
678
/ 336-8503
T
ELE
PH
ON
E
678/ 33
6-8
508 F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
16
17
18
19
20
21
22
23
24
25
PROVIDE 20A., 120V. A QUAD ISOLATED GROUND RECEPTACLE FOR DE-MARK TELEPHONE TERMINALBOARD AND TELEPHONE SYSTEM TERMINAL BOARD.
PROVIDE 120V CONNECTION FOR FREEZER DOOR HEATER, CONDENSATE HEAT-TRACE AND HEAT AIRRELIEF VENT IN FREEZER. PROVIDE CONNECTIONS PER MANUFACTURERS REQUIREMENTS AND N.E.C.ARTICLE 300-7 (2008).
PROVIDE CORD & PLUG FOR VENT-LESS HOOD AND CONNECT AS REQUIRED. VENT-LESS HOOD HASINTERLOCK FOR FRYER, WIRE FRYER INTO VENT-LESS HOOD SYSTEM.
CONTRACTOR TO PROVIDE SINGLE POINT CONNECTION TO FREEZER CONDENSING UNIT (FCU) ANDCIRCUIT AS INDICATED. E.C. TO CONNECT PROVIDED WIRING HARNESS THAT INTERCONNECTS FCUAND FREEZER EVAPORATOR AS REQUIRED BY MANUFACTURER. INSTALL PER NEC 430-102 AND 300-7(2008).
CONTRACTOR TO PROVIDE SINGLE POINT CONNECTION TO COOLER CONDENSING UNIT (CCU) ANDCIRCUIT AS INDICATED. E.C. TO CONNECT PROVIDED WIRING HARNESS THAT INTERCONNECTS CCUAND COOLER EVAPORATOR AS REQUIRED BY MANUFACTURER. INSTALL PER NEC 430-102 AND 300-7(2008).
OVENS - 2P30A., 240V., MANUAL MOTOR STARTING SWITCH WITHOUT OVERLOADS WITH STAINLESSSTEEL LOCKOUT AND TAG OUT COVER PLATE. E.C. TO MAKE FINAL CONNECTION TO EXHAUST FAN EF-1FROM SWITCH. E.C. TO PROVIDE RECEPTACLES TO MATCH OVEN PLUG CONFIGURATION IF OVENS AREPROVIDED WITH FACTORY INSTALLED CORD AND PLUG.
SEE DRAWING SHEET E1.0 F0R EXHAUST FAN INTERLOCK DETAILS.
DISHWASHER - 60A., 3P., 240V., MANUAL MOTOR STARTING SWITCH WITHOUT OVERLOADS WITHSTAINLESS STEEL LOCKOUT AND TAG OUT COVER PLATE.
PROVIDE QUAD OUTLET TO ACCOMMODATE CURRENT CSR STATION AND ALLOW FOR FUTURE CSRSTATION, TO BE ADDED AT A LATER TIME.
1P20A, 115V, 3 WIRE ISOLATED GROUND RECEPTACLE, NEMA 5-20P LOCATED WITHIN 11" OFCENTERLINE OF COUNTER.
1P20A., 115V., 3 WIRE RECEPTACLE, NEMA 5-20P.
1P30A., 120V., 2 WIRE NEMA L5-30P RECEPTACLE.
PROVIDE CONNECTION FROM DUCT SMOKE ANNUNCIATORS TO DUCT SMOKE DETECTORS.SEE SMOKE MONITORING SYSTEM NOTE SHEET E1.0.
FIRE SUPPRESSION SYSTEM IS INTEGRAL WITH VENT-LESS HOOD.
RECEPTACLE TO BE PROVIDED ONLY WHEN CCTV EQUIPMENT IS REQUIRED. MOUNTRECEPTACLE AT 90".
PROVIDE SINGLE POINT CONNECTION TO AIR HANDLER ABOVE CEILING AND CIRCUIT ASINDICATED.
PROVIDE 3P60A FUSIBLE DISCONNECT FOR CONDENSING UNIT IN NEMA-3R ENCLOSURE.CONTRACTOR TO MAKE FINAL CONNECTION TO CU FROM DISCONNECT.
PROVIDE WEATHERPROOF GFI SERVICE RECEPTACLE FOR CONDENSING UNITS.
BREAKERS FOR DEVICES UNDER HOOD ARE TO BE PROVIDED WITH SHUNT TRIP RELAY.
CONTRACTOR TO PROVIDE RECEPTACLE FOR FUTURE PROOFER.
CONTRACTOR TO PROVIDE RECEPTACLE RECESSED IN CEILING FOR FUTURE DISPATCH.
EDWARDS CAT. NO. 44 ROLLING BALL CONTACTOR MOUNTED IN DOOR FRAME FORACTIVATION OF DOOR CHIME. INSTALL PER MANUFACTURER'S INSTRUCTIONS. J-BOXMINIMUM 2 1/4" DEEP AND MOUNT ABOVE CEILING. INSTALL PER
EDWARDS CAT. NO. 338-G5 SINGLE-STROKE WALL MOUNTED CHIME. PROVIDE 4" OCTAGONOR SQUARE BOX (TYP. OF 2). INSTALL PER MANUFACTURER'S INSTRUCTIONS.
EDWARDS CAT. NO. 590 CLASS 2 SIGNALING TRANSFORMER AND EDWARDS 593TRANSFORMER MOUNTING PLATE FOR DOOR CHIME SYSTEM. PROVIDE TWO GANGMANUFACTURER'S INSTRUCTIONS.
PROVIDE 24 VOLT LOW VOLTAGE WIRING PER MANUFACTURES REQUIREMENTS. CONNECTAND INSTALL PER MANUFACTURER'S INSTRUCTIONS. PROVIDE CONDUIT FOR LOW VOLTAGEWIRING IF REQUIRED BY LOCAL CODE.
50 NEMA 3R
2020 1 FUSTAT
PANEL DEVICEPOLE
OP
LE
DEVICE AT UNIT
OTHER
SETS
REMARKS
NOTES BELOW
FEEDER DESCRIPTION
RTU ROOF TOP UNIT1 208/3 - - - B-2/4/6
EF EXHAUST FAN1 120/1 .75 13.8 1.656 A-292 120/1 .17 4.4 0.528 A-2034
UNIT
VOLTAGE
UNIT
DESIG.
LOAD
H.P. FLA KVACIRCUIT
NUMBEROR SEE PANEL SCHEDULES
20CCE COOLER CONDENSER & EVAPORATOR1 208/3 13.0 5.4 B:16/18/20
FCE FREEZER CONDENSER & EVAPORATOR1 208/3 3.8 5.4 A:38/40/42 20
50 NEMA 3R2 208/3 - - - B-8/10/12
T
A
A
3B
3B
L2
L
A:19
1
95
A:18
WP A:28J
5
4
A:24
A:14
A:38
145
A
A
A AA
A
A2 A2
1
A:209
T
S176"
S176"
70"
24"
60"
PATCH PANEL2 COMPUTER
78"
1
18"
S4
J116"
24"
3
3
2
S4
E3.0
ELEC LIGHTING
PLAN
TELEPHONE COMPANY DEMARK BOARD - PROVIDE (1) 2" CONDUIT WITH PULLSTRING FROM TELEPHONE TERMINAL BOARD TO TELEPHONE SERVICE ENTRANCE.PROVIDE SWEEPING 90° ELBOWS AT ALL TURNS. VERIFY SITE AND TELEPHONECOMPANY REQUIREMENTS PRIOR TO BIDDING. SEE ARCHITECTURAL ELEVATIONDETAIL FOR SIZE AND MOUNTING.
PROVIDE (1) 2" CONDUIT WITH PULL STRING STUBBED UP ABOVE TO ACCESSIBLECEILING FROM J-BOX AT COMPUTER WALL CABINET FOR DATA CABLES. PROVIDESWEEPING 90° ELBOWS AT TURNS.
PROVIDE (1) PULL STRING STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM EACHVOICE, VOICE/DATA AND DATA OUTLET.
TELEPHONE TERMINAL BOARD FOR PIZZA HUT TELEPHONE SYSTEM. SEEARCHITECTURAL ELEVATION DETAIL FOR SIZE AND MOUNTING.
REQUIREMENTS WITH SECURITY PROVIDER.
REQUIREMENTS WITH SECURITY PROVIDER.HOLD UP BUTTON BY MANAGER DESK. VERIFY EXACT LOCATION AND
NOT USED.
HOLD UP BUTTON LOCATION (MOUNT 2 1/2" BEHIND COUNTER EDGE). VERIFY
KEYED NOTES 2
LIGHTING PLAN 1/4"=1'-0" 1
OVERHEAD TELEPHONE BELL PROVIDED BY PHONE INSTALLER.
REQUIREMENTS WITH SECURITY PROVIDER.CONDUIT THROUGH WALL, STUB UP ABOVE CEILING. VERIFY EXACT LOCATION ANDHOLD UP BUTTON ABOVE COOLER/FREEZER DOORS. MOUNT AT TOP OF JAMB WITH
KEY NOTES B
1
2
3
4
5
S1
S2
S3
S4
K
A
NO. LOCATION MANUFACTURER / ITEM NUMBER FIXTURE TYPE / BALLAST
ACRYLIC LENS
SUPPLIED W/ FIXTURE
F32T8 LAY-IN GRID
MOUNTING VOLTAGE W REMARKS
KITCHEN 120 96
CEILING EXIT FIXTURE WITH EMERGENCY BATTERY. SEE FIXTURE SCHEDULE NOTE #2.3
LIGHTOLIER / XP2GVA232120SO
LITHONIA / L Q M S W 3 R ELN
2' X 4' TROFFER / ELECTRONIC
LED EXIT / -
3
- 120ENTRY
TYPE#LAMPS
A2 ACRYLIC LENS, 'PROVIDE WITH EMERGENCY BATTERY BACK-UPF32T8 LAY-IN GRIDKITCHEN 120 96THOMAS/ CM6/ FV26/ V65B/ BH3 2' X 4' TROFFER / ELECTRONIC 3
L F32T8 SIGN MOUNTED ABOVE ARCHITECTURAL CLOUD, VERIFY MOUNTING LOCATION64SIGN LIGHT 4' FLUORESCENT / ELECTRONIC 2 120ENTRY
F25T8 SIGN MOUNTED ABOVE ARCHITECTURAL CLOUD, VERIFY MOUNTING LOCATION6412023' FLUORESCENT / ELECTRONICSIGN LIGHTENTRYL2
1
LIGHTING NATIONAL ACCOUNT:ACCUSERV LIGHTING:
ACCUSERV HAS AGREED TO PROVIDE A PHOTOMETRICS STUDIES FOR ALL DELCOS. ONCE AN EQUIPMENT PLAN IS COMPLETE, EMAIL THE AS-BUILT AND BASE PLANS TOACCUSERV FOR PHOTOMETRIC. EACH SPACE WILL BE DESIGNED FOR A MIN. OF 50
PRIMARY CONTACT: BUDDY BOCKWEGPHONE: (877) 707-7378FAX: (502) 961-0357EMAIL: [email protected]
FOOT CANDLES THROUGH OUT THE SPACE. ACCUSERV HAS AGREED TO RETURN THE PHOTO METRIC WITH LIGHTING LAYOUT WITHIN 48 HOURS.
1
2
3
4
5
6
7
8
9
10
B 13W CFL RECESSED --26LYTECASTER / 1113CFL RECESSED DOWN LIGHTING 2 120FRONT COUNTER
DELCO LT
PLOT DATE:
PIZZA HUT
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
LIS PROJECT:
DELCO LT
09-11.01.09
307351
2010YB017
5479 POTTSVILLE PIKELEESPORT, PA 19533
arch
ite
ctu
re
AR
CH
IT
EC
TU
RE
EN
GIN
EE
RIN
G
LA
ND
D
EV
EL
OP
ME
NT
2030 P
OW
ER
S F
ER
RY
R
OA
D
SU
IT
E 2
04
AT
LA
NT
A, G
EO
RG
IA
30339
67
8/ 33
6-85
03 T
EL
EP
HO
NE
678/ 336-8508
F
AC
SIM
ILE
OS
WE
LL
+
N
IT
IS
HIN
SUPPLIED W/ FIXTURE TRACK --641203TRACK HEADSWAC LIGHTING/ LHT826BN/ WTENTRYL3
- - ---120-4' TRACKLIGHTOLIER/ 6004WHENTRYLB
PROVIDE TWO (2) 2-GANG JUNCTION BOXES FOR ALL LOW VOLTAGE CABLING.6
PROVIDE (2) PULL STRINGS STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM EACH OFTWO VOICE, VOICE/DATA AND DATA OUTLETS. BOTH OUTLETS TO BE MOUNTED AT 24" AFF.
7
PROVIDE (1) PULL STRING STUBBED UP ABOVE ACCESSIBLE CEILING FROM FUTURE VOICE AND DATA OUTLET. OUTLET TO BE MOUNTED IN CEILING FOR FUTURE DISPATCH USE.
8