chapter 2 ipm: pest detection and monitoring · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5...
TRANSCRIPT
![Page 1: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/1.jpg)
2019
![Page 2: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/2.jpg)
Air Liquid
Add 1.7 liters to the bottle:
25 strokes = 1.4 bar40 strokes = 2.4 bar
15 cm 1.7 liters
2 liters in the bottle make it heavy to carry and limits the pressure head-space
Head space
![Page 3: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/3.jpg)
Air Liquid
Add 3.5 quarts to the bottle:
25 strokes = 20 psi40 strokes = 35 psi
6 in.3.5 quarts
4 quarts in the bottle make it heavy to carry and limits the pressure head-space
Head space
![Page 4: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/4.jpg)
Pump tube
seal
Bottle
gasket
Opening for
siphon tube
Inside the
sprayer cap
Sprayer
cap
Check
valve
Hose
seal
24000001
![Page 5: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/5.jpg)
# 17017408
# 17017403
# 17017404
# 17017401
# 17017407
![Page 6: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/6.jpg)
Tips are not inter-changeable
5700-B and Injection tip
Adjustable and Foaming tip
![Page 7: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/7.jpg)
![Page 8: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/8.jpg)
F80-04 flow rate:
1.4 bar = 1 liter / min 1-second trigger = 18 ml (25 pump strokes = 1.4 bar)
2.0 bar = 1.3 liters / min1-second trigger = 24 ml(40 pump strokes = 2.0 bar)
![Page 9: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/9.jpg)
Add foaming agent to the liquid or use product with foaming agent included
Add minimum amount of foaming agent to bottle
![Page 10: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/10.jpg)
Open the nozzle about 1/8 turn until the cone spray matches diameter of the screen mesh then attach the foam tip
1/8th turn
Foam tip
Screen mesh
Clean screen regularly
![Page 11: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/11.jpg)
![Page 12: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/12.jpg)
1.4 liters in bottle:
1.4 bar = 0.6 liter / min(25 pump strokes)
2.0 bar = 0.8 liter / min (40 pump strokes)
![Page 13: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/13.jpg)
The standard 15 cm C+C straw
#22049200
![Page 14: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/14.jpg)
The 2 inch / 5 cm crack- crevice straw can also be used in the nozzle
15 cm C+C straw = 114 ml / min 5 cm C+C straw = 180 ml / min
#22071703
![Page 15: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/15.jpg)
Adjustable tip does not have an ‘off’ position… when tip is closed it will produce a cone spray open slightly to get a pin-stream
17017401
![Page 16: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/16.jpg)
1.4 bar = 300 ml / min / cone510 ml / min / pin
(25 pump strokes )
2.0 bar = 300 ml / min / cone720 ml / min / pin
(40 pump strokes)
17017401
![Page 17: Chapter 2 IPM: PEST DETECTION AND MONITORING · 25 strokes = 20 psi 40 strokes = 35 psi 6 in. 3.5 quarts 4 quarts in the bottle make it heavy to carry and limits the pressure head-space](https://reader033.vdocument.in/reader033/viewer/2022041818/5e5c9361dba2572436673378/html5/thumbnails/17.jpg)