CITY OF TUCKER
ACKNOWLEDGE RECEIPT OF ADDENDUM #1 FORM
ITB #2020-005 Renovation of Leased Space
Upon receipt, please print and add to your proposal I hereby acknowledge receipt of the supplement pertaining to the above referenced bid. COMPANY NAME:
CONTACT PERSON:
ADDRESS:
CITY: STATE: ZIP:
PHONE: FAX:
EMAIL ADDRESS:
SIGNATURE DATE
ADDENDUM #1
ITB #2020-005
Renovation of Leased Space Questions Received:
1. Can the City please post the pricing sheet? a. Yes, the pricing sheet is now posted with the answers.
2. Will the bid include appliances? a. No, those will be done separately.
3. The plans indicate that there will be a wheelchair lift. Is that the case and if so, where. Is the lift located.
a. No wheelchair lifts. 4. Are there any pictures of the existing interior space?
a. No 5. Will there be a schedule time to visit the site?
a. A time has not been scheduled for the site visit. 6. The ITB lists that the work will include work to the fire sprinkler system. Is there
an approved vendor that must be used? a. The preferred sprinkler company Fire Sprinkler System - Century Fire
Protection, Ben Colbert, Office – 770-506-2388; Cell# 770-876-3040 7. Is low voltage cabling to be included or is that being handled separately, and if so
by whom? a. The low voltage cabling will be handled by the City of Tucker.
8. The ITB indicates matching the existing doors. What are the type of doors and veneer?
a. Not known at this time. 9. What is the existing key system? Will it be included or handled separately?
a. This will be handled separately by the City of Tucker. 10. Are there specific subcontractors that have to be used?
a. The following subcontractors are approved to work in the building. Contractors will state the subcontractor being used in their proposal. The building property manager or tenant project manager will have to approve use of non-approved subcontractors. The only subcontractor that must be used is Mitec for fire alarm.
i. Electrical Contractor - Allison Smith, Craig Vandiver, Office – 404-351-6430 cell# 404-456-9281
ii. Fire Alarm Systems – Mitec, Matt Ording, Office – 770-813-5959 Cell# 404-472-7600
iii. Fire Sprinkler System - Century Fire Protection, Ben Colbert, Office – 770-506-2388, Cell# 770-876-3040
iv. Plumbing Contractor - Art Plumbing, Marty Carrol, Office – 770-3232 Cell # 404-316-5214
v. HVAC Contractor - McKenney’s, Tracy Venters, Office- 404-624-8600 Cell# 404-557-6400
11. The document indicates use of roller shades. Where are those located and what is the scope of the shades for inclusion?
a. No roller shades in the project. 12. It looks like the last sheet might be missing as there are references to roller shades
and other items not included? a. No roller shades in the project.
13. The included schedule includes only 2 months. This is a short amount of time for award and buildout considering long lead times on some items. Will the City consider lengthening the project timeline?
a. No 14. It appears that the sheets in the general notes indicates fire alarm demo with the
approved subcontractor. Who is the subcontractor? Done separately or with this bid?
a. Mitec must be used for the fire alarm. 15. What is the reference to Mitec on page 3?
a. This if the company that must be utilized for the fire alarm. 16. Will the City cover the permit fees?
a. Yes 17. Are the Inspections all performed by the City?
a. No some are City, and some are County. 18. When the City moves to the new space, will it be fully occupied.
a. Yes, the space is full except for a few growth offices. 19. Will the City be starting operations immediately?
a. Yes, the startup will be end of June. 20. Is there a budget set?
a. No, it has not specifically set. 21. Can the bid submission be electronic?
a. Yes 22. Has the project been funded by the City?
a. Yes 23. How can the drawings be obtained?
a. Email [email protected]. 24. Will the Q&A post the list the attendees?
a. Yes, to the best of my ability I will include what I heard on the phone. The attendees could please email for better listing.
25. Are the hours to work restricted? a. No
26. Are there any noise restrictions? a. No
27. Is there any indication of the facility being shut down and if so, how will the City address the issue?
a. Currently, there is no indication of a shutdown. However, if the City/State/Federal government shut down this type of work the City would have to address the timeline accordingly.
28. There are some items that have long lead times. Would the City pay for storage on these items.
a. No, the City would not pay for storage. However, that can be included in the bid.
29. Are the bathrooms operational? a. Yes
30. Is there an area that can be used in parking lot for lay down/storage containers on site?
a. Yes, but this would need to be coordinated with the Tenant Project Manager.
31. Is there ample parking for the contractors? a. Yes
32. Who attended the pre-bid conference: Todd Salmon, Green Heart Enterprises Richard Murrah, Diversified Construction Marc Johnson, Multiplex Jan Phillips, Striker contracting Bryan Haynes, BMK Construction Robb Dean, McCallan Group Maish Paryani, Paryani Construction Avinash Karnati, Stryker Contracting Kevin Door, Green Heart Enterprises Wesley, Lovern Construction Jeremiah Johnson, Merit Construction Serkan Saglam, Buildline Construction Robert Morrison, BE Guthrie Construction Gary Frantz, Prime Contractors Inc. Uriah Bullard, Cloud Construction Terrell Lews, FS360 Rob Wasserman, Macallan Works
33. Have the drawings already been permitted and approved? a. The plans have been submitted for permit and pending review and
approval. 34. Is there ample parking in the existing parking lot for workers and a dumpster
location: a. Yes
35. Will the project schedule be adjusted for any delays caused by any mandated City or Government shutdowns?
a. Currently, there is no indication of a shutdown. However, if the City/State/Federal government shut down this type of work the City would have to address the timeline accordingly.
36. Can the City pay for stored materials to help expedite delivery of any long lead time items?
a. No, the City would not pay for storage. However, that can be included in the bid.
37. Is the existing building space already sprinkled? a. Yes
38. Is there anyway to take pictures of the existing electrical panel box, space conditions, and/or flooring?
a. The City does not currently have plans to include these items. 39. Do the drawings show the existing deck height?
a. No 40. Is the FFE package part of our price proposal?
a. No 41. Who is handling the A/V Cabling?
a. City of Tucker 42. What appliances are we pricing?
a. Listed in appliance schedule on sheet A2.08. Reference elevations for counts.
43. Are there existing window treatments? a. Yes
44. What is the existing wood door finish to be matched? a. All existing doors will be painted.
45. What is the City of Tucker door core standard? a. Door core will be building standard.
46. Who will inspect the building prior to occupation? a. The inspections will be conducted by both the City of Tucker and Dekalb
County. 47. Can you confirm cashier stations 212 and 213 are in our scope? Plans show it both
ways. a. Yes, see sheets issued with answers.
48. The chambers desk is shown in the elevations but there is no additional information or cross sections. Can we get more information on this?
a. See sheets issued with answers. 49. More information is needed on the feature wall.
a. The feature wall has standard lumber trim pieces to be painted.
DRAWING ABBREVIATIONS SHEET NUMBERING BUILDING SUMMARY
LEGEND
AAC AIR CONDITIONINGACT ACOUSTICAL CEILING TILEADD ADDENDUMADD'L ADDITIONALADJ ADJACENTAFF ABOVE FINISHED FLOORALT ALTERNATEANOD ANODIZEDAPPROX APPROXIMATEARCH ARCHITECTURAL
BBETW BETWEENBF BACKFACEBLKG BLOCKINGBOT BOTTOMBW BEARING WALL
CC COMPACT PARKING SPACECC CUBICK CURTAINCDR CARD READERCL CENTER LINECLG CEILINGCLR CLEARCOL COLUMNCONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUOUSCOORD COORDINATECOOR CORRIDORCT CERAMIC TILECTD CENTEREDCTR CENTERCW CURTAIN WALL
DD DEPTHDET DETAILDF DECORATIVE FILMDIA DIAMETERDIM DIMENSIONDN DOWNDRG DRAWINGDWGS DRAWINGS
EEA EACHEF EACH FACEEL ELEVATIONELEC ELECTRICEQ EQUALEQUIP EQUIPMENTEW EACH WAYEWC ELECTRIC WATER COOLEREXIST EXISTINGEXT EXTERIOR
FFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF FINISH FLOORFHC FIRE HOSE CABINETFIN FINISHFLR FLOORFS FAR SIDEFT FOOTFT FLOOR TRANSITIONFV FIELD VERIFY
GGA GAUGEGALV GALVANIZEDGEN GENERALGI GALVANIZED IRONGL GLASSGND GROUNDGR GRADEGRG GLASS-REINFORCED GYPSUMGYP BD GYPSUM BOARD
HHDW HARDWAREHDWD HARDWOODHK HOOKHM HOLLOW METALHOR HORIZONTALHP HIGH POINTHR HOURHS HEADED STUDHT HEIGHTHW HAND WASHHW HEAD OF WALL
IIBC INTERNATIONAL BUILDING
CODEID INSIDE DIAMETERINSUL INSULATIONINT INTERIOR
KKP KICKPLATEKPD KEYPAD
LL ANGLELAV LAVATORYLG LONGLKB LOCKABLELLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLOC LOCATIONLP LOW POINTLT LIGHT
MMAT'L MATERIALMAX MAXIMUMMECH MECHANICALMEMB MEMBRANEMEP MECHANICAL, ELECTRICAL
AND PLUMBINGMFG MANUFACTURERMIN MINIMUMMISC MISCELLANEOUSMOD MODIFIEDMTL METAL
NNA NOT AVAILABLENIS NOT IN SCOPENOM NOMINALNS NEAR SIDENTS NOT TO SCALE
OOA OVER ALLOC ON CENTEROD OUTSIDE DIAMETEROD OVERFLOW DRAINOFCI OWNER FURNISHED,
CONTRACTOR INSTALLEDOFOI OWNER FURNISHED, OWNER
INSTALLEDOH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEOSF OUTSIDE FACE
PP LAM PLASTIC LAMINATEPCF POUNDS PER CUBIC FOOTPL PLATEPLUMB PLUMBINGPLYWD PLYWOODPP PUSH PLATEPOL POLISHEDPR PAIRPREFAB PREFABRICATEDPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT POINTPTD PAINTED
RR RISERRAD RADIUSRCP REFLECTED CEILING PLANREBAR REINFORCING BARRECP RECEPTACLEREF REFER OR REFERENCEREINF REINFORCINGRELOC RELOCATE/RELOCATEDREQ'D REQUIREDRM ROOMRO ROUGH OPENING
SAB SOUND ATTENUATION BLANKET
SBC STANDARD BUILDING CODESCHED SCHEDULES/H SINGLE HUNGSHWR SHOWERSIM SIMILARSO STRUCTURAL OPENINGSOG SLAB ON GRADESPA SPACE, SPACINGSPEC SPECIFICATIONSQ SQUARESS STAINLESS STEELSSF SOLID SURFACESTA STATIONSTC SOUND TRANSMISSION
CLASSSTD STANDARDSTIFF STIFFENERSTL STEELSTRUC STRUCTURALSYM SYMMETRICALSYS SYSTEM
S
TT TREAD T&B TOP AND BOTTOMTC TOP OF CURBTEL TELEPHONETEMP TEMPERATURETHK THICKTLT TOILETTO TOP OFTOB TOP OF BEAMTOF TOP OF FOOTINGTOS TOP OF SLABTOSTL TOP OF STEELTW TOP OF WALLTYP TYPICAL
UU/C UNDER COUNTER U/G UNDERGROUNDUNO UNLESS NOTED OTHERWISE
VAR VARIES VCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVWC VINYL WALL COVERING
V
W/ WITHW/C WHEEL CHAIRW/O WITHOUTW WIDTHWP WATERPROOF(ING)WD WOODWF WIDE FLANGEWL WIND LOADWP WORK POINTWPO WORK POINT - POINT OF
ORIGINWP1 WORK POINT - NUMBERED
W
NUMBERING SYSTEM:
A2.10/01
DISCIPLINE:C - CIVILL - LANDSCAPEA - ARCHITECTUREM - MECHANICALE - ELECTRICALP - PLUMBINGS - STRUCTURALK - FOOD SERVICE
SERIES NUMBER
SHEET NUMBER WITHIN SERIES
NUMBER OF PLAN, DETAIL, ETC. ON SHEET
CONCRETE/ PRECAST CONCRETE
SAND, EIFS FINISH COAT, OR CEMENT PLASTER
GLASS MINERAL FIBER BATT INSULATION
GYPSUM BOARD
COATED GLASS MAT WATER RESISTANT GYP BD
PLYWOOD
MATERIALS
FIRE RESISTANTCONSTRUCTION/FIREPROOFING SCHEDULE
INDEX OF DRAWINGS
GENERAL NOTES
ROOM NAME ABBREVIATIONS
AADMIN ADMINISTRATION
CCOMM COMMUNITYCONF CONFERENCE
MMED MEDIUM
RM ROOM
R
WWK RM WORKROOM
SSTOR STORAGE
DDEV DEVELOPMENT
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES HAVING JURISTICTION.
2. ALL WORK SHALL BE PREFORMED IN ACCORDANCE WITH PROCEDURES SET FORTH BY THE PROPERTY MANAGMENT. SEE BUILDING'D CONTRACTOR REGULATIONS.
3. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS.
4. CONTRACTOR IS RESPONSIBLE FOR EXAMINGING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS BUILDABLE AS HOWN BEFORE SUBMITTING PRICING AND PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ITEMS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT AND/OR CONSTRUCTION MANAGER BEFORE PROCEEDING WITH PRICING, WORK IN QUESTION OR RELATED WORK.
5. CONTRACTOR FOR THE PROJECT SALL BE RESPONSIBLE FOR OBTAING ALL REQUIRED BUILDING PERMITS.
6. CONTRACTOR SHALL SUBMIT CONFIRMATIONS WITH DELIVERY DATED FOR ORDERS OF LONG LEAD ITEMS.
7. CONTRACTOR SHALL SUBMIT ELECTRONIC SETS OF SHOP DRAWINS AS REQUIRED BY THE PROJECT SEPCIFICATIONS. SHOP DRAWINGS SHOULD INCLUDE DETAILS FABRICATION AND REECTION DRAWINGS, SETTING DRAWINGS, DIAGRAMATIC DRAWINGS AND MATERIAL SCHEDULES. LOCATION AND ORIENTATION OF ALL ITEMS SHALL BE CLEARLY INDICATED. BEGIN FABRICATION ONLY AFTER RECIEVING ARCHITECT'S OR CONSTRUCTION MANAGER'S FINAL REVIEW OF SHOP DRAWINGS.
8. SUBSTITUTION REQUESTS WILL BE CONSIDERED DURING THE PRICING PERIOD AND THEREAFTER ONLY WHEN A PRODUCT BECOMES UNAVAILABLE. ALL REQUESTS FOR SUBSTITUTIONS OF ITEMS SPECIFIED SHALL BE SUBMITTED IN WRITING WITH THOROUGH PRODUCT AND ENGINEERING DATA FOR ARCHITECT'S REVIEW. WILL
BE CONSIDERED ONLY IF BETTER SERVICE FACILITIES, A MORE ADVANTAGEOUS DELIVERY DATE, OR A LOWER PRICE WITH CREDIT TO THE OWNER WILL BE PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCE WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED.
9. ALL WORK INDICATED ON DRAWINGS AND SPECS SHALL BE INCLUDED BY CONTRACTOR UNLESS SPECIFICALLY EXCLUDED OR NOTED N.I.C. PRICING SHALL INCLUDE ALL WORK REQUIRED FOR COMPLETE, THOROUGH AND PROFESSIONAL INSTALLATION.
10. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE FINISHES IN THE SAME PLANE.
11. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS THROUGHOUT, UNO.
12. ALL VERTICAL DIMENSIONS SHOWN TO FLOOR ARE TO FINISH FLOOR, UNO
13. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS.
14. ALL PARTITION LOCATIONS, DIMENSIONS AND TYPES AND ALL DOOR AND WINDOW LOCATIONS SHALL BE SHOWN ON FLOOR PLANS. IN CASE OF CONFLICT, NOTIFY ARCHITECT.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL CLEANING OF A JOB AFTER IT'S COMPLETION. CLEANING SHALL INCLUDE INTERIOR OF THE BUILDING AND PATH OF TRAVEL TO THE JOB SITE AND SHALL INCLUDE THE PARKING LOT, ELEVATORS, LOBBIES AND CORRIDOR CARPET.
16. CONTRACTOR SHALL PROVIDE RECORD DOCUMENTS AND SHALL PROVIDE SAID DOCUMENTATION TO THE ARCHITECT FOR TRANSMISSION TO THE OWNER UPON COMPLETION OF CONSTRUCTION.
17. CONTRACTOR SHALL PROTECT AREA OF WORK, PUBLIC AREA IN PATH TO WORK AND ADJACENT AREAS FROM DAMAGE.
18. CONTRACTOR SHALL MAINTAIN A SECURE AND LOCKABLE WORK ARE DURING CONSTRUCTION. COORDINATE WITH AFFECTED TENANTS AND LANDLORD TO ENSURE SECURITY.
19. REQUIED EXIT WAYS, INCLUDING STAIRS, LANDINGS, RAMPS, AND SIDEWALKS SHALL BE CLEAR OF ALL OBSTRUCTIONS.
20. FOR METAL FABRICATIONS, CONTRACTOR SHALL VERIFY SCREW ANCHOR ATTACHMENTS TO EXISTING SLAB OR COLUMNS DOES NOT CUT OR DAMAGE EXISTING REINFORCEMENT OR POST TENSTIONED STRANDS.
LOCATION PLAN
PROJECT INFORMATIONPROJECT NAME: TUCKER CITY HALLADDRESS: 1975 LAKESIDE PARKWAY, TUCKER, GA 30084SUMMARY: NEW INTERIOR OFFICE BUILD-OUT WITHIN EXISTING COMMERCIAL OFFICE BUILDING.
APPLICABLE CODES
BUILDING PLANNINGOCCUPANCY: BUSINESS / ASSEMBLY A-3MIXED OCCUPANCY: YES REQUIRED FIRE SEPARATION: B / A-3 1 HR
TYPE OF CONSTRUCTIONCONSTRUCTION TYPE: I-A
GENERAL BUILDING LIMITATIONS
ESSENTIAL FACILITY (CHAPTER 16, IBC)ESSENTIAL FACILITY: NO (IBC CHPTR. 16)
ITEM ALLOWED / REQUIRED ACTUAL / PROVIDED
HEIGHT OF BUILDING
NUMBER OF STORIES
MAX SINGLE FLOOR AREA
TOTAL AREA OF BUILDING
UNLIMITED 100' - 4'
UNLIMITED 6
UNLIMITED 15,840 SF GROSS
UNLIMITED 187,220 SF GROSS
HIGH RISE: NO
MANDATORY CODES: INTERNATIONAL BUILDING CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014) (2015) (2017) (2018)INTERNATIONAL FIRE CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014)INTERNATIONAL PLUMBING CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014) (2015)INTERNATIONAL MECHANICAL CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014) (2015)INTERNATIONAL FUEL GAS CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014) (2015)NATIONAL ELECTRICAL CODE, 2017 EDITION (NO GEORGIA AMENDMENTS)INTERNATIONAL ENERGY CONSERVATION CODE, 2009 EDITION, WITH GEORGIA SUPPLEMENTS AND AMENDMENTS (2011) (2012)
PERMISSIVE CODES: INTERNATIONAL PROPERTY MAINTENANCE CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2015)INTERNATIONAL EXISTING BUILDING CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2015)NATIONAL GREEN BUILDING STANDARD, 2008 EDITION, WITH GEORGIA AMENDMENTS (2011)
ACCESSIBILITY:GEORGIA ACCESSIBILITY CODE 120-3-20 (“GAC”)AMERICANS WITH DISABILITIES ACT, ACCESSIBILITY GUIDELINES - STANDARDS FOR ACCESSIBLE DESIGN 2010 EDITION
LIFE SAFETYLIFE SAFETY CODE (NFPA 101), 2012 EDITION WITH GEORGIA AMENDMENTSINTERNATIONAL FIRE CODE, 2012 EDITION, WITH GEORGIA AMENDMENTS (2014)NFPA 13, 2013 EDITION
FIRE PROTECTION SYSTEMS- FIRE EXTINGUISHING SYSTEM: YES
- STANDPIPE SYSTEM: YES
- SMOKE CONTROL: NO
TYPE: 13
FIRE RESISTANT CONSTRUCTION/FIREPROOFING SCHEDULEITEM REQ'D RATING / HR UL/FM # WHERE APPLICABLE
- EXTERIOR WALLS: LOAD BEARING
- EXTERIOR WALLS: NON-LOAD BEARING
- FIRE/PARTY WALLS
- SHAFTS
- TENANT SEPARATION
- INTERIOR WALL: LOAD BEARING
- INTERIOR WALL: NON-LOAD BEARING
- COLUMNS
- BEAMS
- FLOOR/CEILING
- ROOF/CEILING
3 HRS
1 HR
1 HR
1 HR
1 HR
3 HRS
0 SEE PARTITION TYPE SHEETS
3 HRS
3 HRS
2 HRS
1.5 HRS
FIRE PROOFING NOTES1. ALL FIRE RESISTIVE RATINGS ARE ASSUMED TO BE THERMALLY RESTRAINED.
2. ALL BEAMS AND COLUMNS SHALL BE ADJUSTED USING W/D OR A/P RATIOS TO DETERMINE THE CORRECT FIREPROOFING THICKNESS.
LOCATION MAP1975 LAKESIDE PARKWAYTUCKER, GA 30084
1975 LAKESIDE PARKWAY
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
35 P
M
A0.01
PROJECTINFORMATION
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
INDEX OF DRAWINGS
SHEET NAME SHEET ISSUE DATE
GENERALCOVER 03/12/2020LIFE SAFETY PLAN 03/12/2020PROJECT INFORMATION 03/12/2020SPECIFICATIONS 03/12/2020SPECIFICATIONS 03/12/2020SPECIFICATIONS 03/12/2020ARCHITECTUREDEMOLITION PLAN 03/12/2020FLOOR PLAN 03/12/2020ENLARGED TOILET PLANS AND ACCESSORIES 03/12/2020REFLECTED CEILING PLAN 03/12/2020ENLARGED CEILING PLANS AND DETAILS 03/12/2020POWER & COMMUNICATION PLAN 03/12/2020FINISH PLAN 03/12/2020FINISH SCHEDULE & TRANSITION DETAILS 03/12/2020PARTITION TYPE & FRAMING 03/12/2020CABINET DETAILS 03/12/2020DOOR, SAFETY GLAZING AND SCHEDULE INFORMATION 03/12/2020INTERIOR ELEVATIONS 03/12/2020INTERIOR ELEVATIONS 03/12/2020INTERIOR ELEVATIONS 03/12/2020MILLWORK SECTIONS & DETAILS 03/12/2020SPECIALTY MILLWORK DETAILS 03/26/2020FURNITURE PLAN - FOR REFERENCE ONLY 03/12/2020MECHANICALABBREVIATIONS, LEGEND, & SCHEDULES - MECHANICAL 03/12/2020DETAILS - MECHANICAL 03/12/2020SPECS - MECHANICAL 03/12/2020SEPECS - MECHANICAL 03/12/2020SPECS - MECHANICAL 03/12/2020LEVEL 01 - DEMO PLAN - MECHANICAL 03/12/2020LEVEL 01 FLOOR PLAN - MECHANICAL 03/12/2020ELECTRICALLEGENDS & NOTES - ELECTRICAL 03/12/2020FIRE STOPPING DETAILS 03/12/2020ELECTRICAL SPECIFICATIONS 03/12/2020ELECTRICAL SPECIFICATIONS 03/12/2020LIGHT FIXTURE SCHEDULE & COM CHECK REPORT 03/12/2020LEVEL 01 FLOOR PLAN - ELECTRICAL 03/12/2020LEVEL - MECHANICAL CONNECTIONS 03/12/2020PLUMBINGABBREVIATIONS, LEGEND, SCHEDULES & DETAILS - PLUMBING 03/12/2020SPECS - PLUMBING 03/12/2020SPECS - PLUMBING 03/12/2020LEVEL 01 FLOOR PLAN - PLUMBING 03/12/2020
1
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
J
DOCK+2'-0"
RAMP
0'-0"
PROBATION209
OFFICE121
HUDDLE205
HUDDLE206
GCIC STOR.207
CASHIER212
CASHIER213
UNISEX TOILET215
UNISEX TOILET216
STORAGE214
LOBBY201
COURTCHAMBERS
163
WAITING AREA202
HUDDLE208
A5.01
08
A5.01
04
A5.01
09
A5.01 05
A5.02
02
A5.02 01
A5.02
A5.0209
A5.02
11
A5.02 1312
01
02
A5.02
07
05
03 A5.0204
A5.0208
OFFICE124
OFFICE125
OFFICE126
OFFICE127
OFFICE152
OFFICE151
OFFICE150
OFFICE129
OFFICE130
OFFICE131
OFFICE132
OFFICE154
OFFICE159
OFFICE160
HUDDLE161
OFFICE149
OFFICE148
OFFICE147
ELECTRICAL157
SERVER RM123
MED CONF125
OFFICE120
COM ADMIN133
LARGECONFERENCE
135
MED CONF134
PERMITINTAKE
104
HUDDLE137
OFFICE138
OFFICE139
OFFICE140
OFFICE141
OFFICE142
OFFICE143
OFFICE144
OFFICE107
MED CONF108
OFFICE109
OFFICE110
OFFICE111
OFFICE112
OFFICE113
OFFICE115
OFFICE116
OFFICE114
PRINT/COPY117
BREAK ROOM118
OFFICE119
AV204
OPEN OFFICE158
CORRIDOR153
STOR146
STOR145
CORRIDOR136
CORRIDOR122
COM DEVINTAKE
102
OFFICE106OFFICE
105
HUDDLE155
IDF156
CORRIDOR203
EXECUTIVECONF
128
A5.01 10
11
A5.0107
10
06
A5.03
02
A5.03
01
A5.03 03
A5.03
05
A5.03
04
1' - 0"
1' - 0"
2' - 6"
3' - 0"
3' - 0"
4' - 11 1/2"12' - 0"
1' -
0"
1' - 0"
1' -
0"
1' - 0"1' - 0"
1' -
6"
14' -
10
1/4"
12' - 4 1/4"
A5.01
03
LOBBY101
ALIG
N
12' - 4 7/8" 5' - 4 7/8" 12' - 4 7/8" 5' - 10 7/8" 12' - 4 7/8" 47' - 2 3/8"
2' -
11 1
/8"
5' -
7 7/
8"10
' - 6
5/8
"58
' - 3
3/4
"12
' - 4
3/8
"
8' - 4 7/8" 8' - 4 7/8" 14' - 2 1/2" 8' - 0"2' - 9 1/4"
5' - 4 7/8"
8' -
2 1/
8" 2' -
6 5/
8"
8' -
4 7/
8"7'
- 10
1/2
"8'
- 4
7/8"
8' -
4 7/
8"16
' - 9
3/4
"8'
- 4
7/8"
10' - 6 1/4" 10' - 6 1/4" 10' - 8 3/4"8' - 5 1/2" 8' - 5 1/2" 8' - 5 1/2" 8' - 5 1/2"
ALIG
N
12' -
1 1
/2"
8' -
10 1
/2"
7' -
5 1/
4"12
' - 4
7/8
"5'
- 4
7/8"
12' -
4 7
/8"
8' - 5 3/4" 8' - 5 3/4" 8' - 5 3/4" 8' - 5 3/4" 8' - 5 3/4" 8' - 5 3/4" 8' - 5 3/4"
7' -
0 1/
8"
8' -
4 7/
8"8'
- 4
7/8"
8' -
4 7/
8"12
' - 5
5/8
"
10' -
4 7
/8"
8' -
7 3/
4"10
' - 4
7/8
"7'
- 10
1/2
"8'
- 8
1/8"
8' -
5 3/
4"8'
- 8
1/8"
7' - 11 3/4" 6' - 5 1/2"
4' -
11 7
/8"
133°
7' -
4 1/
8"
96°
18' - 4 7/8" 21' - 7 1/8" 7' - 7 1/4" 12' - 4 7/8"
15' - 8"
6' - 4 7/8"
4' - 8 1/8"
2' - 8"
10' - 4 7/8"
11' -
8 1
/4"
ALIGN
124°
146°
12' - 9 1/8" 5' - 0 3/8"
ALIGN
/A2.03 05
COM DEV WKRM103
SECURITYVESTIBULE
200
WAITING AREA210
PROBATION211
ALIGN
8' -
0"
ALIGN
8' -
5 7/
8"
ALIGN
ALIG
N
7' - 2 3/4"
ALIG
N
ALIG
N
ALIG
N2'
- 11
1/8
"
ALIG
N
ALIG
N
1' - 0"
ALIG
N
90°
90°
87°
90°
13' -
0"
8' - 4 7/8"
15' - 4 7/8" 90°
ALIGN
12' -
2 5/8"
1' - 7"
90°
9' - 2
3/8"
1' - 3 3/4"
ALIGN
1' - 0"
1' - 0"
6"
R 11
1' - 4
1/4
"11
3/8
"
8 7/8"
5' - 7 3/8"
7' -
8"
7"
ALIG
N
84°
R 1
05' -
0 5
/8"
6' - 8 1/2"
130° 2' - 6 1/2"
9' - 6
3/8"
8' - 5 1/2"1' - 0 1/8"
15' - 8 5/8"
137
2' -
10 1
/2"
ALIGN
16' - 2 1/2"
138
139
140
141
143
144
116
115
114
113
112
111
110
109
108
107
105
106
104A
136104B
135A
134A
155
161
103
158
142
156
157
13316
015
9
154
131
130
129
132
152
127
126
151
125
150 124
149
148
147
146 145
121A
123
203
216
215
214A
213
128A
125
204
205
206
207
208
201
211A
209A
128B
101
135B
134B
209B
211B
121B
119B
153
8"
6' -
0"6'
- 0"
8"
120B
/A5.05 01
ALIGN
ALIGN8"
8"
214B
A3
A3
A3A3A3
A3
A3
A3
A3
A3
A3
A3
A3
H3
A3A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
H3
A3
A3 A3
A3
A3
A3 A3
A3A3
A3
06
140°
14' - 11 1/4"6' - 11 1/4"
2' - 7 1/8"
7' - 0"
2' - 7 1/8"
3' - 11"
H3
H3
H3
H3
15' -
2"
2' - 9 1/8"
H3
H3
H3
H3
H3
H3H
3
H3
H3
H3
H3H3
H3
H3H3
H3
8' - 6"
3' -
7 3/
4"
H3
H3
H3
H3
ALIGNALIGN
H3H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3H3 H
3
H3
H3 H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3
H3 H3
H3
H3
H3
B
B
B B
B
B
B
B
B
B
B
B B
BB
B
B
B B B B
B
B
B
B
STEP+0'-6"
+0'-6"
UP
6' -
0"
R 44' - 10"
14' -
0"
14' -
0"
RAM
P
53' - 5"
29' -
4 3
/8"
3' - 8"
A5.03 06 A5.0307
120A
119A
217
2' -
7"
1
ROOM NAMEXXXXX
X
A0.XX
X
A3
A3
ROOM NAME/NUMBER
EXISTING COLUMN CENTERLINE
KEYED NOTES
BUILDING WALL SECTION
SECTION DETAIL
PLAN, BLOW-UP DETAIL
PARTITION TYPE WITH NO SOUND ATTENUATION
PARTITION TYPE WITH SOUND ATTENUATION
NEW WALL
EXISTING WALL
DRAWING SYMBOLS
01
A0.XX01
A0.XX01
SEMI-RECESSED FIRE EXTINGUISHER CABINET
FEC
AX.XXXX ELEVATION
MILLWORK
NOT IN SCOPE
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
36 P
M
A2.02
FLOOR PLAN
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
1/8" = 1'-0"1 LEVEL 1 - FLOOR PLAN
LEGEND GENERAL NOTES KEY NOTES
1. ALL WALLS TO BE TYPE C, UNLESS OTHERWISE NOTED2. FUR OUT ALL COLUMNS WHERE STRUCTURE IS EXPOSED.3. REFER TO SHEET A3.01 FOR PARTITION TYPES, GRAPHIC AND
SYMBOLIC DESIGNATIONS, NOTES, AND DETAILS.4. REFER TO SHEET A2.03 FOR TYPICAL TOILET LAYOUTS AND TOILET
ACCESSORY MOUNTING DIAGRAMS.5. REFER TO SHEET A3.04 FOR DOOR INFORMATION, SCHEDULES AND
DETAILS.6. REFERE TO SHEET 2.08 FOR ALL APPLIANCE SPECIFICATIONS7. REFERE TO ELEVATIONS FOR ALL APPLIANCE LOCATIONS
RESUSE DOORS WHERE INDICATED ON PLAN. SAND, PRIME AND PAINTA
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
OPEN TO BEYOND
RB-01
IPT-01
4"4"
4"4"
2 1/2" 2 1/2"
IPT-03
EQEQ
2 1/
2"2
1/2"
2 1/2" 2 1/2"
2 1/
2"2
1/2"
EQEQ
2 1/2"
2 1/
2"2
1/2"
2 1/2"2 1/2"2 1/2"
4"4"
2' -
0"2'
- 0"
EQEQ
EQ EQ EQ4' - 2 7/8" 4' - 1 7/8"
EQ EQ EQ EQ
4"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2' -
0"2'
- 0"
IPT-03
2 1/
2"4"
2 1/2"
2' -
10"
PL-02
FILE CABINETS BY OTHERS
10
A5.04
SIM
VIF
PL-03
SS-01
IPT-03
8"2'
- 9"
2"
ALIG
N
ALIG
N
ALIG
N
ALIG
N
SECURITY GLASS
PL-02
3' - 0"3' - 0"3' - 0"
CONSEALED SUPPORTS AS REQUIRED
09
A5.04
SIM
SS-01
PL-03
SECURITY GLASS
1' - 6"1' - 6"
1'
1' - 6" 1' - 6"
1'
1' - 6" 1' - 6"
ø 6"
2' -
6"1'
- 0"
4' - 0"
EQEQ
2' - 0"
ALIG
N
ALIG
N
ALIG
N
ALIG
N
ALIG
N
VIF
EQ EQ EQ
06
A5.05
07
A5.05
EQ EQ
2 1/2" 2 1/2" 2 1/2"
2' -
0"5'
- 2
1/2"
1' -
9 1/
2"
4"2
1/2"
2 1/
2"4"
IPT-03
AMAZON, DESIGNSTYLES WALL HANGING 3 TIER FILE HOLDER -WALL MOUNTED METAL WIRE MAGAZINE RACK -OFFICE FOLDER ORGANIZER WITH NAME TAG SLOT, COPPER
EQ EQ
1' - 9" 1' - 9"
5' -
6"
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
37 P
M
A5.01
INTERIORELEVATIONS
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
3/8" = 1'-0"04 LOBBY 101 - FEATURE WALL
3/8" = 1'-0"03 LOBBY 101 - MED CONFERENCE FRONT3/8" = 1'-0"02 LOBBY 101 - CONFERENCE ROOM FRONTS
3/8" = 1'-0"01 LOBBY 101 - HUDDLE ROOM FRONT
3/8" = 1'-0"05 LOBBY 101 - FEATURE WALL - NORTH SOUTH
3/8" = 1'-0"10 LARGE CONFERENCE 135 - DRAWING STORAGE
3/8" = 1'-0"08 COM ADMIN 133 - RECEPTION COUNTER FRONT3/8" = 1'-0"07 COM ADMIN 133 - COMPUTER INPUT COUNTER
3/8" = 1'-0"11 COM ADMIN 133 - RECEPTION COUNTER BACK3/8" = 1'-0"09 COM ADMIN 133 - FEATURE WALL WRAP
3/8" = 1'-0"06 COM ADMIN 133 - ENTRY WALL
1
1
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
2' -
10"
PL-03
8 EQ DOORS12' - 0"
PL-0203
A5.04
SIM
OPEN TO BEYONDOPEN TO BEYONDOPEN TO BEYOND
1' -
10"
5' -
1 3/
4"1'
- 8"
4"
8' - 6 3/4" 1' - 2 1/2" 7' - 11 1/2" 1' - 2 1/2"
7'-0" A.F.F
IPT-03
7'-0" A.F.F 7'-0" A.F.F
7' - 2 1/2"
2 1/2"
2 1/
2"
4"
IPT-03
2' -
0"
2 1/2"
4"2
1/2"
2 1/
2"
2' -
0"
OPEN TOBEYOND
SS-01
2' -
10"
5' -
2"
1' - 0"4' - 6"
PL-02
PL-03
1 1/2"
02
A5.04
SIM
1 1/2"
14 EQ DOORS17' - 0 5/8"
1"
OPEN TOBEYOND
2' -
10"
PL-03
1 1/2"
8 EQ DOORS11' - 1 7/8"
ALIG
N
PL-01
PL-02
06
A5.04
SIM
01
A5.04
SIM
1 1/2"
ALIG
N
PL-01
PL-02
PL-03
06
A5.04
SIM
01
A5.04
SIM
1 1/2"11 EQ DOORS
13' - 9"
1"
ALIG
N
PL-03
6' -
2"1
1/2"
2' -
8 1/
4"
09
A5.04
SIM
3' - 0"3 EQ DOORS
6' - 0"
PL-01
SS-01
PL-03
IM
2' -
10"
MW
MW
REFREF
DW
SINK
FAUCET
1' - 6"2' - 3 7/8"
06
A5.04
SIM
04
A5.04
SIM
08
A5.04
SIM
07
A5.04
SIM05
A5.04
SIM
PL-02
12' - 0"
2' -
10"
PL-03
03
A5.04
SIM
OPEN TOBEYOND
2' -
10"
5' -
2"
4' - 6"
SS-01
1 1/2" 1 1/2"
6 EQ DOORS9' - 10 1/2"
PL-02
PL-03
01
A5.04
SIM
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
39 P
M
A5.02
INTERIORELEVATIONS
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
3/8" = 1'-0"03 COM DEV WK RM 103 - MILLWORK FRONT3/8" = 1'-0"01 COM DEV INTAKE 102 - FRONT
3/8" = 1'-0"02 COM DEV 102 - PARTITION
3/8" = 1'-0"06 PERMIT INTAKE 104 - INTAKE WINDOW3/8" = 1'-0"07 PERMIT INTAKE 104 - MILLWORK
3/8" = 1'-0"12 PRINT/COPY 117 -3/8" = 1'-0"13 PRINT/COPY ELEVATION 14 - B
3/8" = 1'-0"10 BREAK ROOM 118 - WINDOW LEDGE3/8" = 1'-0"09 BREAK ROOM 118 - WORK WALL
3/8" = 1'-0"04 COM DEV WK RM 103 - MILLWORK BACK
3/8" = 1'-0"05 COM DEV INTAKE 102 - INTAKE WINDOW
3/8" = 1'-0"08 CORRIDOR 136 - PRINT STATION3/8" = 1'-0"11 PRINT/COPY 117 - CORRIDOR
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
SS-01
2' -
6"
PL - 03
08
A5.03
09
A5.03
2' - 0" 2' - 0"
SS-01
PL-03
SECURITY GLASS
EQEQ EQEQ
09
A5.03
PL-03
PL-02
1 1/2" 7' - 3" 1 1/2"
IPT-05
01
A5.04
SIM
FILES BY OTHERS
7' -
0"
1 1/2"6 EQ DOORS
7' - 10 1/2"
01
A5.04
SIM
1 1/2"
PL-02
PL-03
IPT-03
EQ EQ
EQ EQ
2 1/2"2 1/2" 2 1/2"
4"2
1/2"
2 1/
2"4"
2' -
0"2'
- 0"
IPT-03
4"2
1/2"
2 1/
2"4"
2 1/2" 2 1/2" 2 1/2"
2' -
0"2'
- 0"
EQ EQ
PLASTIC LAMINATE DRAWER FRONTS
3/4"
1 1/
2"
4"
2'
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SLIDING DRAWER HARDWARE
SOLID SURFACE COUNTERTOP
2' - 6"
3"
1 1/
2"
SOLID SURFACE COUNTERTOP
SECURITY GLASS
2' -
6"
2' - 6"
4"
3"
EQ EQ
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
39 P
M
A5.03
INTERIORELEVATIONS
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
3/8" = 1'-0"04 CASHIER 212 & 213 - RECEPTION COUTNER BACK3/8" = 1'-0"05 CASHIER 212 & 213 RECEPTION COUNTER FRONT
3/8" = 1'-0"01 OPEN OFFICE PRINT STATION3/8" = 1'-0"02 OPEN OFFICE FILING NICHE
3/8" = 1'-0"03 CORRIDOR 153 - HOSPITALITY STATION
3/8" = 1'-0"06 SECURITY VESTIBULE 200 - FEATURE WALL3/8" = 1'-0"07 WAITING AREA 210 - FEATURE WALL
1 1/2" = 1'-0"08 CASHIER'S - STORAGE1 1/2" = 1'-0"09 CASHER'S - TRANSATION COUNTER
1
11
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
PLASTIC LAMINATE TOEKICK
3/4"
1 1/
2"
4"
4"
REF
ER T
O E
LEVA
TIO
N
2' - 1"
SOLID SURFACE COUNTERTOP AND BACKSPLASH
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SOLID SURFACE COUNTERTOP AND BACKSPLASH
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
PLASTIC LAMINATE TOEKICK
3/4"
1 1/
2"
4"
4"
REF
ER T
O E
LEVA
TIO
N
2' - 1"MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
PLASTIC LAMINATE TOEKICK
2' - 6"
3/4"
3"
4"
REF
ER T
O E
LEVA
TIO
N
1 1/
2"
SOLID SURFACE COUNTERTOP AND BACKSPLASH
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
PLASTIC LAMINATE TOEKICK
3' - 0"
3/4"
3"
4"
REF
ER T
O E
LEVA
TIO
N
1 1/
2"
SOLID SURFACE COUNTERTOP AND BACKSPLASH
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
3/4"
REF
ER T
O E
LEVA
TIO
N
1' - 3"
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
PLASTIC LAMINATE COUNTER TOP AND VALENCE ON CONTINUOUS WALL CLEAT; TWO LAYERS PLYWOOD CLAD IN PLASTIC LAMINATE AND VALENCE
2' -
10"
1' - 6".
1 1/
2"
PLASTIC LAMINATE COUNTER TOP CONTINUOUS WALL CLEAT; TWO LAYERS PLYWOOD CLAD IN PLASTIC LAMINATE AND VALENCE
2' -
10"
3' - 0"
1 1/
2"
MAX
5 1/
2".
SOLID SURFACE COUNTEROP
SEALANT AROUND EDGE OF SINK
ACCESSIBLE FAUCET
ACCESSIBLE UNDERMOUNT SINK
4"
PLASTIC LAMINATE DOOR FRONT
WHITE MELAMINE INTERIOR, TYP.
INTERGRAL PLASTIC LAMINATE TOEKICK
WRAP EXPOSED PLUMBING
AT F
LOO
R1/
2" C
LR
3"
REF
ER T
O E
LEVA
TIO
N
19"
FLOORING TO CONTINUE INTO CABINET
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
PLASTIC LAMINATE DOOR FRONTS
SHELF PINS
3/4"
3' - 0"
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
REF
ERE
TO E
LEVA
TIO
N
PLASTIC LAMINATE DOOR FRONT
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
MICROWAVE TRIM KIT
MICROWAVE
4"
3"
VAR
IES
- REF
. ELE
VATI
ON
WHITE MELAMINE INTERIOR TYP.
3' - 0"
SHELF PINS
2' -
8 1/
2"
1' -
3 1/
4"
3' - 0"
MICROWAVE
SHELF PINS
DRYWALL HEADER
PLASTIC LAMINATE DOOR FRONT
DOOR PULL
SELF CLOSING, FULL OVERLAY, CONCEALED HINGES W/ HINGE BASE PLATES (2 PER DOOR)
WHITE MELAMINE INTERIOR TYP.
MICROWAVE TRIM KIT
1' -
3 1/
4"
PLASTIC LAMINATE TOEKICK
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
40 P
M
A5.04
MILLWORKSECTIONS &DETAILS
03/12/2020
ISSUED FORCONSTRUCTION
3.0.
0.20
1706
23
1 1/2" = 1'-0"01 BASE CABINET - 24" P-LAM SURFACE1 1/2" = 1'-0"04 BASE CABINET - 24" SOLID SURFACE
1 1/2" = 1'-0"02 BASE CABINET - 30" PLAM SURFACE1 1/2" = 1'-0"03 BASE CABINET - 36" PLAM SURFACE
1 1/2" = 1'-0"06 UP CABINET - 15" P-LAM SURFACE
1 1/2" = 1'-0"09 COUNTER - 18" PLAM SURFACE1 1/2" = 1'-0"10 COUNTER - 36" PLAM SURFACE
1 1/2" = 1'-0"08 SINK COUNTER 24"1 1/2" = 1'-0"07 UP CABINET - 36" PLAM SURFACE
1 1/2" = 1'-0"05 MICROWAVE CABINET
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
A5.050204
A5.05
05
A5.05
STEP+0'-6"
UP03
A5.05
WITNESSSTAND
CITY COUNCIL PLATFORM
RAMP+0'-6"
CLR5' - 6"
2' - 6"
6' -
0"
5' - 0"
2' -
7"
PL-03
ML-01
IPT-3
SEAL BY OTHERSPROVIDE BLOCKING AS REQUIRED
ADD ALTWC-04 04
A5.05
COUNTER SUNK FASTNERS
3' - 3"
1'
PLASTIC LAMINATE COUNTERTOP
PLASTIC LAMINATE TOEKICK
1 1/
2"
SOLID SURFACE
SOLID SURFACE
SAFETY GLASS
3"
3' - 6"
8"
REF
ER T
O E
LEVA
TIO
N
STRUCTURE AS REQUIRED
PL - 03
2"1/2"
2' -
6"
4"
3"
1' -
0"
2"
9"
4"
6"
2"
3' - 0"
FLOORING AS SCHEDULED
STRUCTURE AS REQUIRED
PLASTIC LAMINATE COUNTERTOP
PLASTIC LAMINATE DRAWER FRONTS
PLASTIC LAMINATE TOEKICK
3/4"
1 1/
2"
4"
REF
ER T
O E
LEVA
TIO
N
2'
3'
3"
4"
SAFETY GLASS
MOCKETT - DP3B - 90DP3 SERIES - TAB DRAWER PULL - 1-1/2" PROFILE
3"
SLIDING DRAWER HARDWARE
4"
3"
3' -
0"
2"
3' - 0"
2' -
6"
4"
3"
5' - 6"
3"
2"
9"
4"
2"
3' - 0"
3' -
0"1'
- 0"
REVISION
HKS PROJECT NUMBER
DATE
SHEET TITLE
SHEET NO.
PLO
T D
ATE:
ISSUE
© 2019 HKS, INC.
TEM
PLAT
E VE
RSI
ON
:
BARRETT, WOODYARD & ASSOCIATES, INC.
NORCROSS, GA 30092
MEP ENGINEER
3495 HOLCOMB BRIDGE ROAD
CIT
Y O
F TU
CK
ER,
CIT
Y H
ALL
AT
1975
LA
KES
IDE
PAR
WA
Y
HKS, INC.
ATLANTA, GA 30303
ARCHITECT
191 PEACHTREE STREET, NE SUITE 5000
23789.000
LAKESIDE CENTERPROPERTY ADDRESS
1975 LAKESIDE PARKWAYTUCKER, GA 30084
CITY OF TUCKEROWNER
4119 ADRIAN STREETTUCKER, GA 30084
3/27
/202
0 12
:57:
40 P
M
A5.05
SPECIALTYMILLWORK DETAILS
03/12/2020
ISSUED FOR PERMIT
3.0.
0.20
1706
23
1/4" = 1'-0"01 COURT DAIS ENLARGED PLAN3/8" = 1'-0"02 COURT CHAMBERS ELEVATION 9 - A
1 1/2" = 1'-0"06 COM DEV RECEPTION DESK - TRANSACTION COUNTER
1 1/2" = 1'-0"04 DAIS - CENTER SECTION DETAIL
1 1/2" = 1'-0"07 COM DEV RECEPTION DESK - STORAGE1 1/2" = 1'-0"05 DAIS - WITNESS END SECTION DETAIL
1 1/2" = 1'-0"03 DAIS - LOWER LEVEL SECTION DETAIL
NO. DESCRIPTION DATE
1 PERMITCOMMENTS
03/26/2020
PROJECT BID FORM RSF 22,078.00 City of Tucker - 1975 Lakeside Parkway $/SF
DIV WORK ITEM COST SUBCONTRACTOR01 General Requirements
PermitsGeneral ConditionsBondsContractors Fee
02 Demolition03 Concrete04 Masonry05 Metals06 Wood, Plastic, & Laminates
Carpentry/MillworkRough Carpentry
07 Thermal & Moisture ProtectionRoofing
08 OpeningsDoors, Frames, HardwareGlass & Glazing
09 FinishesDrywallAcousticalCeramic, Stone, TileFlooringPainting, Wallcoverings
10 SpecialtiesToilet Partitions & Accessories
11 Equipment12 Furnishings
AppliancesWindow Treatments
13 Special Construction14 Conveying Equipment21 Fire Supression
SprinklerFire Extinguishers
22 Plumbing23 HVAC25 Integrated Automation26 Electrical27 Communications28 Electronic Safety & Security
Fire AlarmOther(Please specify):
/----/TOTAL CONSTRUCTION -
ALTERNATES (List Below) COST123
Company Name:
Address:
Contact Person:
Phone Number:
eMail Address:
Signature: